SL-ALARM-MIB

        This MIB module describes the ALARMS.
    
Source file
SL-ALARM-MIB
Last revised
Identity
slAlarmMib
Base OID
1.3.6.1.4.1.4515.1.3.20
Imported Objects
IF-MIB InterfaceIndex
PerfHist-TC-MIB PerfCurrentCount PerfIntervalCount PerfTotalCount
SL-MAIN-MIB slMain slmTrapLogId
SNMPv2-CONF MODULE-COMPLIANCE (no object page) NOTIFICATION-GROUP (no object page) OBJECT-GROUP (no object page)
SNMPv2-SMI MODULE-IDENTITY (no object page) NOTIFICATION-TYPE (no object page) OBJECT-TYPE (no object page)
SNMPv2-TC DisplayString TEXTUAL-CONVENTION (no object page) TimeStamp TruthValue
Net-SNMP examples using the smartoptics MIB directory Show commands

These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.

Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'SL-ALARM-MIB' -M '/opt/observium/mibs/smartoptics:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'SL-ALARM-MIB::slAlarmMib'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SL-ALARM-MIB' -M '/opt/observium/mibs/smartoptics:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SL-ALARM-MIB::slAlarmMib'
How SNMP, Net-SNMP, MIB paths, and variants work
Objects (15)
.1.3.6.1.4.1.4515.1.3.20
.1.3.6.1.4.1.4515.1.3.20.1
.1.3.6.1.4.1.4515.1.3.20.1.1
.1.3.6.1.4.1.4515.1.3.20.1.1.1
.1.3.6.1.4.1.4515.1.3.20.1.1.1.1
.1.3.6.1.4.1.4515.1.3.20.1.1.1.2
Enumeration
.1.3.6.1.4.1.4515.1.3.20.1.1.1.3
.1.3.6.1.4.1.4515.1.3.20.1.1.1.4
.1.3.6.1.4.1.4515.1.3.20.1.1.1.5
.1.3.6.1.4.1.4515.1.3.20.1.1.1.6
.1.3.6.1.4.1.4515.1.3.20.1.1.1.7
.1.3.6.1.4.1.4515.1.3.20.1.1.1.8
.1.3.6.1.4.1.4515.1.3.20.2
.1.3.6.1.4.1.4515.1.3.20.2.0
.1.3.6.1.4.1.4515.1.3.20.2.1
Dependencies (9) 6 direct · 3 transitive Show tree and compile order Hide dependency details

Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.

Dependency tree
Dependency-first compile order
  1. SNMPv2-SMIrfc
  2. SNMPv2-TCrfc
  3. IANAifType-MIBrfc
  4. SNMPv2-CONFrfc
  5. SNMPv2-MIBrfc
  6. IF-MIBrfc
  7. PerfHist-TC-MIBrfc
  8. SL-NE-MIBsmartoptics
  9. SL-MAIN-MIBsmartoptics
  10. SL-ALARM-MIBsmartopticsselected
Type Definitions (1)
Enumeration
losSonetAlarm(1)
lofSonetAlarm(2)
lopSonetAlarm(3)
aisLineSonetAlarm(4)
rfiLineSonetAlarm(5)
uneqSonetAlarm(6)
timLine(7)
slm(8)
sd(9)
sf(10)
hwfail(11)
aisPathSonetAlarm(12)
rfiPathSonetAlarm(13)
timPath(14)
uplinkTransmitMismatch(15)
uplinkClockSourceLol(16)
aisVtSonetAlarm(21)
lopVtSonetAlarm(22)
rfiVtSonetAlarm(23)
timVt(24)
slmVt(25)
uneqVtSonetAlarm(26)
lomVt(27)
vcgFarLossClientSignal(101)
vcgFarLossClientSync(102)
vcgLossAlignment(103)
vcgLossMultiframe(104)
vcgLossSequence(105)
vcgGfpLossSync(106)
vcgFarGfpLossSync(107)
vcgBadGidMember(108)
provUnequipped(151)
provMismatch(152)
ethConfigTransmitFault(201)
ethConfigLossOfSignal(202)
ethConfigLinkFail(203)
ethConfigPcsLossSync(204)
encAisFault(221)
encRdiFault(222)
encKeyExchangeFailed(223)
fcBxPortTransmitFault(301)
fcBxPortLossOfSignal(302)
fcBxPortNoLink(303)
fcBxPortLossOfSync(304)
fcBxPortTransmitMismatch(306)
fcBxPortPcsLossSync(307)
fcipLinkNoLink(311)
fcipLinkLossOfSync(312)
fcipSntpFailure(313)
fcipIpsecFailure(314)
fcipFarLossOfClient(315)
esconPortTransmitFault(351)
esconPortLossOfSignal(352)
esconPortNoLink(353)
esconPortLossOfSync(354)
edfaPumpTemperuture(401)
edfaHwFail(403)
edfaRvcSignalDetect(404)
edfaRcvPower(406)
edfaTemprature(407)
edfaEyeSafty(408)
edafGainFlatness(409)
edfaXmtPower(410)
edfaGain(411)
edfaEol(412)
muxAisPath(451)
muxLof(452)
muxRdi(453)
muxInbandFail(454)
muxTempLicense(455)
muxNoLicense(456)
oswHwFail(470)
oswLossOfSignal(471)
oswEdfaLossProp(472)
dcmTemp(475)
dcmTec(476)
dcmHwFault(477)
loopback(501)
apsForceActive(502)
apsManualActive(503)
cluHoldoverState(602)
cluFreerunState(603)
cluBelowLevel(604)
cluFail(606)
cluJittered(608)
channelLowDegrade(621)
channelHighDegrade(622)
channelLowFail(623)
channelHighFail(624)
unequalizedOuputPower(625)
sfpTransmitFault(701)
sfpRemoved(702)
sfpMuxWlMismatch(703)
sfpBitRateMismatch(704)
sfpLossOfLock(705)
sfpSfpWlMismatch(706)
sfpLossOfLight(707)
sfpLaserEndOfLife(708)
sfpMuxSpacingMismatch(709)
sfpHardwareFault(710)
sfpBlocked(711)
sfpLossPropagation(712)
sfpUnknownType(713)
sfpTxLossOfLock(714)
sfpHighTemp(720)
sfpLowTemp(721)
sfpHighTxPower(726)
sfpLowTxPower(727)
sfpHighRxPower(728)
sfpLowRxPower(729)
sfpHighLaserTemp(730)
sfpLowLaserTemp(731)
sfpHighLaserWl(732)
sfpLowLaserWl(733)
xfpTxNR(734)
xfpTxCdrNotLocked(735)
xfpRxNR(736)
xfpRxCdrNotLocked(737)
otnFecExc(750)
otnFecDeg(751)
otnOtuDeg(752)
otnOduDeg(753)
otnLos(754)
otnLof(755)
otnLom(756)
otuAis(757)
otuBdi(758)
otuTtim(759)
oduAis(780)
oduOci(781)
oduLck(782)
oduBdi(783)
oduTtim(784)
oduPtm(785)
oduApsMismatch(786)
otnOtuFail(787)
otnOduFail(788)
entityRemoved(801)
entityClockFail(803)
entityHwTxFail(804)
entitySwMismatch(806)
entitySwUpgrade(807)
entitySwInvalidBank(808)
entityIpLanPending(820)
entityIpOscPending(821)
nePowerFault(902)
neFanFault(903)
neLowVoltagePower(904)
entitySwUpgradeFail(905)
entityRadiusPrimFail(906)
entityRadiusSecFail(907)
entityDbRestoreFail(908)
entityDbRestoreInProgress(909)
entitySntpFail(910)
dcActive(1001)
lcpDown(1002)
ncpDown(1003)
rtcFailure(1004)
Notifications / Traps (2)
NameOIDDescription
.1.3.6.1.4.1.4515.1.3.20.2.0.2
An slAlarmTrap0 notification is sent when an alarm occures.
It is defined to support browsers that don't recognize RFC 2576.
.1.3.6.1.4.1.4515.1.3.20.2.2
An slAlarmTrap notification is sent when an alarm occures.