AC-PM-Analog-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
1
Rows
1
Columns
10
.1.3.6.1.4.1.5003.10.9.2.31.21 · 1 row entry · 10 columns
Uses the audiocodes variant from /opt/observium/mibs/audiocodes.
Command help
Walk acPMOffHookChannelsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'AC-PM-Analog-MIB' -M '/opt/observium/mibs/audiocodes:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'AC-PM-Analog-MIB::acPMOffHookChannelsTable'
Number of active (off-hook) analog lines.
acPMOffHookChannelsEntry row .1.3.6.1.4.1.5003.10.9.2.31.21.1
Column Syntax OID
Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last.
Unsigned32
Constraints:
range: 0-2
.1.3.6.1.4.1.5003.10.9.2.31.21.1.1
Value of gauge or counter.
SNMPv2-SMIGauge32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5003.10.9.2.31.21.1.2
Average value with in the period time.
Integer32
Constraints:
range: -1-2147483647
.1.3.6.1.4.1.5003.10.9.2.31.21.1.3
Maximum value with in the period time.
Integer32
Constraints:
range: -1-2147483647
.1.3.6.1.4.1.5003.10.9.2.31.21.1.4
Minimum value with in the period time.
Integer32
Constraints:
range: -1-2147483647
.1.3.6.1.4.1.5003.10.9.2.31.21.1.5
Activity volume.
Integer32
Constraints:
range: -1-2147483647
.1.3.6.1.4.1.5003.10.9.2.31.21.1.6
Percent of interval time for which gauge is below what was determined
as the low threshold.
Integer32
Constraints:
range: -1-100
.1.3.6.1.4.1.5003.10.9.2.31.21.1.7
Percent of interval time for which gauge is above what was determined
as the high threshold.
Integer32
Constraints:
range: -1-100
.1.3.6.1.4.1.5003.10.9.2.31.21.1.8
Percent of interval time for which gauge is between what were
determined as the low and high thresholds.
Integer32
Constraints:
range: -1-100
.1.3.6.1.4.1.5003.10.9.2.31.21.1.9
The average of full 24 hours.
Integer32
Constraints:
range: -1-2147483647
.1.3.6.1.4.1.5003.10.9.2.31.21.1.10