is used to inform network management system that a delta
fault event (events that are automatically cleared) has occured
or a normal fault event (not automatically cleared) state has
been set on.
Objects are used as follows:
- eventSeqNum is the sequence number of the event. For normal
type of events must equal to the sequence number of the event
in the events table.
- eventEventId specifies what fault event has occured.
- eventName specifies the name of the fault event.
- eventSetTime indicates when fault event has occured
(delta events) or when fault has been set on (normal events).
- eventSeverity reports the severity level of the event.
- eventInstanceType indicates what kind of object is faulty.
- eventInstanceId specifies what instance is faulty.
- eventInstanceName may contain textual description for
the faulty object.
- eventServAffective specifies whether the event is
immediately service affcetive.
- eventDescription reports possible additional information about the event.
- trapPersistence tells whether this event is a delta or normal event.
- trapSenderNodeId specifies the node ID of the sending network element if
configuring it is supported for the network element, otherwise 0.
- sysObjectID specifies what kind of equipment reports the fault event.
For more information see the eventTable specification
eventClearedTrap
.1.3.6.1.4.1.890.1.5.8.16.27.2.2
is used to inform network management system that a normal
type fault event has been cleared (state set off).
Objects are used as follows:
- eventSeqNum is the sequence number of the this clearing event. Note that
the sequence number of the cleared event is reported in the trapRefSeqNum
object.
- eventEventId specifies what event has been cleared.
- eventSetTime indicates when fault event has been cleared.
- eventInstanceType indicates what kind of object has been
faulty.
- eventInstanceId specifies what instance has been faulty.
- trapRefSeqNum specifies the sequence number of the cleared event (i.e.
the sequence number was assigned for the event in the events table).
- trapSenderNodeId specifies the node ID of the sending network element if
configuring it is supported for the network element, otherwise 0.
- sysObjectID specifies what kind of equipment reports the clearing event.
For more information see the eventTable specification