ZXSONETIF-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
3
Rows
3
Columns
19
.1.3.6.1.4.1.3902.1015.1013.2.1.3.1 · 1 row entry · 6 columns
Uses the zte variant from /opt/observium/mibs/zte.
Command help
Walk zxSonetCfgTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ZXSONETIF-MIB' -M '/opt/observium/mibs/zte:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ZXSONETIF-MIB::zxSonetCfgTable'
The SONET/SDH Medium table.
zxSonetCfgEntry row .1.3.6.1.4.1.3902.1015.1013.2.1.3.1.1
An entry in the SONET/SDH Medium table.
Indexes
Column Syntax OID
zxSonetIfIndexdeprecated
The 4 bytes index includes:
interface type(bit31~28);shelfId(bit27~24);slotId(bit23~16);
portId(bit15~8);reserved(bit7~bit0)
.
IF-MIBInterfaceIndex
Type Constraints:
range: 1..2147483647
Description:
A unique value, greater than zero, for each interface or
interface sub-layer in the managed system. It is
recommended that values are assigned contiguously starting
from 1. The value for each interface sub-layer must …
.1.3.6.1.4.1.3902.1015.1013.2.1.3.1.1.1
Represents the desired loopback configuration of the SONET line.
noLoopback: Not in the loopback state.

lineLoop:
The received signal at this interface does not go
through the device (minimum penetr…
Enumerationr/w
Enumerated Values:
1noLoopback
2lineLoop
3inwardLoop
.1.3.6.1.4.1.3902.1015.1013.2.1.3.1.1.2
The source of Transmit Clock.
'loopTiming' indicates that the recovered
receive clock is used as the transmit clock.

'localTiming' indicates that a local clock
source is used or when an external clock is…
Enumerationr/w
Enumerated Values:
1loopTiming
2localTiming
.1.3.6.1.4.1.3902.1015.1013.2.1.3.1.1.3
Represents the configured line type.This object is used to switch
between SONET(North American)and SDH(European) format.
Sts is SONET format, while Stm is SDH format.
Enumeration
Enumerated Values:
1sonetSts3c
2sonetStm1
3sonetSts12c
4sonetStm4
5sonetSts48c
6sonetStm16
7sonetSts192c
8sonetStm64
.1.3.6.1.4.1.3902.1015.1013.2.1.3.1.1.4
Enumerationr/w
Enumerated Values:
0other
1au3tu11
2au3tu12
3au4tu11
4au4tu12
.1.3.6.1.4.1.3902.1015.1013.2.1.3.1.1.5
The action to send the configuration of
Sonet line to corresponding card.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3902.1015.1013.2.1.3.1.1.6
.1.3.6.1.4.1.3902.1015.1013.2.1.3.2 · 1 row entry · 8 columns
Uses the zte variant from /opt/observium/mibs/zte.
Command help
Walk zxSonetMediumTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ZXSONETIF-MIB' -M '/opt/observium/mibs/zte:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ZXSONETIF-MIB::zxSonetMediumTable'
The SONET/SDH Medium table.
zxSonetMediumEntry row .1.3.6.1.4.1.3902.1015.1013.2.1.3.2.1
An entry in the SONET/SDH Medium table.
Indexes
Column Syntax OID
This variable identifies whether a SONET
or a SDH signal is used across this interface.
Enumerationr/w
Enumerated Values:
1sonet
2sdh
.1.3.6.1.4.1.3902.1015.1013.2.1.3.2.1.1
The number of seconds, including partial seconds,
that have elapsed since the beginning of the current
measurement period. If, for some reason, such as an
adjustment in the system's time-of-day clock, the
current interv…
Integer32
Constraints:
range: 1-900
.1.3.6.1.4.1.3902.1015.1013.2.1.3.2.1.2
The number of previous 15-minute intervals
for which data was collected.
A SONET/SDH interface must be capable
of supporting at least n intervals.
The minimum value of n is 4.
The default of n is 32.
The maximum value o…
Integer32
Constraints:
range: 0-96
.1.3.6.1.4.1.3902.1015.1013.2.1.3.2.1.3
This variable describes the line coding for
this interface. The B3ZS and CMI are used for
electrical SONET/SDH signals (STS-1 and STS-3).
The Non-Return to Zero (NRZ) and the Return
to Zero are used for optical SONET/SD…
Enumerationr/w
Enumerated Values:
1sonetMediumOther
2sonetMediumB3ZS
3sonetMediumCMI
4sonetMediumNRZ
5sonetMediumRZ
.1.3.6.1.4.1.3902.1015.1013.2.1.3.2.1.4
This variable describes the line type for
this interface. The line types are
Short and Long Range
Single Mode fiber or Multi-Mode fiber interfaces,
and coax and UTP for electrical interfaces. The
value zxSonetOther sho…
Enumerationr/w
Enumerated Values:
1sonetOther
2sonetShortSingleMode
3sonetLongSingleMode
4sonetMultiMode
5sonetCoax
6sonetUTP
.1.3.6.1.4.1.3902.1015.1013.2.1.3.2.1.5
This variable contains the transmission
vendor's circuit identifier, for the
purpose of facilitating troubleshooting.
Note that the circuit identifier, if available,
is also represented by ifPhysAddress.
OctetStringr/w
Constraints:
range: 0-255
.1.3.6.1.4.1.3902.1015.1013.2.1.3.2.1.6
The number of intervals in the range from
0 to zxSonetMediumValidIntervals for which no
data is available. This object will typically
be zero except in cases where the data for some
intervals are not available (e.g., in…
Integer32
Constraints:
range: 0-96
.1.3.6.1.4.1.3902.1015.1013.2.1.3.2.1.7
The current loopback state of the SONET/SDH interface. The
values mean:

sonetNoLoop
Not in the loopback state. A device that is not
capable of performing a loopback on this interface
sha…
Bitsr/w
Enumerated Values:
0sonetNoLoop
1sonetFacilityLoop
2sonetTerminalLoop
3sonetOtherLoop
.1.3.6.1.4.1.3902.1015.1013.2.1.3.2.1.8
.1.3.6.1.4.1.3902.1015.1013.2.1.3.3 · 1 row entry · 5 columns
Uses the zte variant from /opt/observium/mibs/zte.
Command help
Walk zxSonetVTConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ZXSONETIF-MIB' -M '/opt/observium/mibs/zte:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ZXSONETIF-MIB::zxSonetVTConfigTable'
The Sonet VT Configuration table.
zxSonetVTConfigEntry row .1.3.6.1.4.1.3902.1015.1013.2.1.3.3.1
An entry in the Sonet VT Configuration table.
Column Syntax OID
The 4 bytes index includes:
interface type(bit31~28);shelfId(bit27~24);slotId(bit23~19);portId(bit18~16);augno(bit15~bit10);
au3/au4no(bit9~bit8);tug3no(bit7~bit6);tug2no(bit5~bit3);tu12/tu11no(bit2~bit0).
IF-MIBInterfaceIndex
Type Constraints:
range: 1..2147483647
Description:
A unique value, greater than zero, for each interface or
interface sub-layer in the managed system. It is
recommended that values are assigned contiguously starting
from 1. The value for each interface sub-layer must …
.1.3.6.1.4.1.3902.1015.1013.2.1.3.3.1.1
This variable represents the desired loopback
configuration of the Sonet VT. Agents
supporting read/write access should return
inconsistentValue in response to a requested
loopback state that the interface does not
sup…
Enumerationr/w
Enumerated Values:
1noLoop
2payloadLoop
3lineLoop
4otherLoop
5inwardLoop
6dualLoop
.1.3.6.1.4.1.3902.1015.1013.2.1.3.3.1.2
The source of Transmit Clock.
'loopTiming' indicates that the recovered
receive clock is used as the transmit clock.

'localTiming' indicates that a local clock
source is used or when an external clock is
Enumerationr/w
Enumerated Values:
1loopTiming
2localTiming
3throughTiming
4adaptive
5enhancedAdaptive
6differential
.1.3.6.1.4.1.3902.1015.1013.2.1.3.3.1.3
The current clock state of the sonet VT interface. the value can be:
FREERUN 0
HOLDOVER 1
ACQUIRING 2
ACUIRED 3.
Integer32
Constraints:
range: 0-127
.1.3.6.1.4.1.3902.1015.1013.2.1.3.3.1.4
The action to send the configuration on
Sonet VT to corresponding card.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3902.1015.1013.2.1.3.3.1.5