maryCtrlCardSwapped trap indicates that the main control
card has swapped to slave card.
zxDslCardUp
.1.3.6.1.4.1.3902.1004.3.2.2
dUp trap indicates that the agent has detected that the
card has been online.
zxDslIfUplinkUp
.1.3.6.1.4.1.3902.1004.3.2.20
The operational status of uplink interface changes to up.
zxDslIfUplinkDown
.1.3.6.1.4.1.3902.1004.3.2.21
The operational status of uplink interface changes to down.
zxDslIfAccesslinkUp
.1.3.6.1.4.1.3902.1004.3.2.22
The operational status of access link interface changes to up.
zxDslIfAccesslinkDown
.1.3.6.1.4.1.3902.1004.3.2.23
The operational status of access link interface changes to down.
zxDslUnexpectedCardTypePlugin
.1.3.6.1.4.1.3902.1004.3.2.24
xpectedCardTypePlugin trap indicates that the card plug
in the given slot is unexpected.
For example, the ethernet user card can be plug in slot 2 of F821
NE with HSMV, when ei8e card be pluged in other slot, this alarm
will be generated.
zxDslUnexpectedCardTypePluginCleared
.1.3.6.1.4.1.3902.1004.3.2.25
xpectedCardTypePluginCleared trap indicates that the
unexpected card plug-in is Recovered.
For example, when ei8e card be unpluged from slot 3 of F821 NE
with HSMV, this clear trap will be generated.
zxDslMaxPortNumPerSlotChanged
.1.3.6.1.4.1.3902.1004.3.2.26
PortNumPerSlotChanged trap indicates that the value of
zxDslSysMaxPortNumPerSlot changed.
zxDslCardChipDown
.1.3.6.1.4.1.3902.1004.3.2.27
dChipDown trap indicates that the card is in abnormal
status.
zxDslCardChipDownCleared
.1.3.6.1.4.1.3902.1004.3.2.28
dChipDownCleared trap indicates that the abnormal card is
Recovered.
zxDslCardDown
.1.3.6.1.4.1.3902.1004.3.2.3
dDown trap indicates that the agent has detected that the
card has been offline.
zxDslCpuLoadAlarm
.1.3.6.1.4.1.3902.1004.3.2.4
LoadAlarm trap indicates that the agent has detected that the
zxDslCardCPULoad object of one card has exceeded the configured threshhold value of
zxDslBoardCpuLoadThreshhold.
zxDslCpuLoadAlarmCleard
.1.3.6.1.4.1.3902.1004.3.2.5
LoadAlarmCleard trap indicates that the agent has detected that the
zxDslCardCPULoad object of one card has less than the configured threshhold value of
zxDslBoardCpuLoadThreshhold.
zxDslSysSntpOffsetOverThreshTrap
.1.3.6.1.4.1.3902.1004.3.2.50.1
zxDslSysSntpOffsetAlarmThreshold is reached.
zxDslSysSntpOffsetUnderThreshTrap
.1.3.6.1.4.1.3902.1004.3.2.50.2
zxDslSysSntpCurrentOffset is below zxDslSysSntpOffsetAlarmThreshold.
zxDslSysSntpSynchFailed
.1.3.6.1.4.1.3902.1004.3.2.50.3
Faied to synchronize time from SNTP server.
zxDslSysSntpSynchFailedCleard
.1.3.6.1.4.1.3902.1004.3.2.50.4
Cleared the alarm of zxDslSysSntpSynchFailed.
zxDslMemoryOverLoad
.1.3.6.1.4.1.3902.1004.3.2.6
oryOverLoad trap indicates that the agent has detected that the
zxDslCardMemUsage object of one card has exceeded the configured threshhold value of
zxDslBoardMemUsageThreshhold.
zxDslMemoryAlarmCleard
.1.3.6.1.4.1.3902.1004.3.2.7
oryAlarmCleard trap indicates that the agent has detected that the
zxDslCardMemUsage object of one card has less than the configured threshhold value of
zxDslBoardMemUsageThreshhold.
zxDslEnvTempExceeded
.1.3.6.1.4.1.3902.1004.3.2.8.1
ure inside the chassis has exceeded
normal operating temperature zxDslEnvTemperatureThreshold.
The zxDslEnvChassisTemperature object identifies the current status.
zxDslEnvBatteriesVoltageFailed
.1.3.6.1.4.1.3902.1004.3.2.8.10
It is generated when the Batteries Voltage is Faild.
zxDslEnvBatteriesVoltageRecovered
.1.3.6.1.4.1.3902.1004.3.2.8.11
It is generated when the Batteries Voltage is Recovered.
zxDslEnvPowerFailed
.1.3.6.1.4.1.3902.1004.3.2.8.12
It is generated when the Power is Faild.
zxDslEnvPowerRecovered
.1.3.6.1.4.1.3902.1004.3.2.8.13
It is generated when the Power is Recovered.
zxDslEnvMonitorInterfaceLinkDown
.1.3.6.1.4.1.3902.1004.3.2.8.14
es that the agent has detected that the
link at the enviroment monitoring inerface has been down.
zxDslEnvMonitorInterfaceLinkUp
.1.3.6.1.4.1.3902.1004.3.2.8.15
es that the agent has detected that the
link at the enviroment monitoring inerface has been up.
zxDslTempUnderThreshTrap
.1.3.6.1.4.1.3902.1004.3.2.8.16
es that the zxDslEnvChassisTemperature is lower
than zxDslEnvTemperatureLowerThreshold.
zxDslTempUnderThreshTrapCleared
.1.3.6.1.4.1.3902.1004.3.2.8.17
It indicates that the zxDslTempUnderThreshTrap has Cleared.
zxDslEnvFanFaultStateChangedTrap
.1.3.6.1.4.1.3902.1004.3.2.8.18
signifies that fault state of a fan has been changed.
zxDslEnvFanFailedInfo indicates the failed fan list.
zxDslEnvFanTotalNumber indicates the total number of fans.
.
zxDslEnvTempNormal
.1.3.6.1.4.1.3902.1004.3.2.8.2
ure inside the chassis has returned to
normal operating temperature zxDslEnvTemperatureThreshold.
The zxDslEnvChassisTemperature object identifies the current status.
zxDslEnvFanFailed
.1.3.6.1.4.1.3902.1004.3.2.8.3
on the device has failed. The
zxDslEnvFanOperstatus object identifies the failed fan Operstatus.
zxDslEnvFanRecovered
.1.3.6.1.4.1.3902.1004.3.2.8.4
on the device has recovered
after failure. The zxDslEnvFanOperstatus object identifies
the recovered Fan Operstatus.
zxDslEnvLossOfPower
.1.3.6.1.4.1.3902.1004.3.2.8.5
vice dying gasp event.It is generated when the device is
power off or power failure.
zxDslEnvSwitchFailed
.1.3.6.1.4.1.3902.1004.3.2.8.6
It is generated when the switch is Faild.
zxDslEnvSwitchRecovered
.1.3.6.1.4.1.3902.1004.3.2.8.7
It is generated when the switch is Recovered.
zxDslEnvExteriorPowerFailed
.1.3.6.1.4.1.3902.1004.3.2.8.8
It is generated when the Exterior Power is Faild.
zxDslEnvExteriorPowerRecovered
.1.3.6.1.4.1.3902.1004.3.2.8.9
It is generated when the Exterior Power is Recovered.