ZTE-AN-GPON-REMOTE-ONU-TRAP-MIB
The MIB module for the OMCI TRAP management of GPON ONU.
- Source file
ZTE-AN-GPON-REMOTE-ONU-TRAP-MIB- Last revised
- Identity
zxAnGponRmOnuNotifications- Base OID
1.3.6.1.4.1.3902.1082.500.20.3
Imported Objects
| SNMPv2-CONF | NOTIFICATION-GROUP (no object page) |
| SNMPv2-SMI | MODULE-IDENTITY (no object page) NOTIFICATION-TYPE (no object page) OBJECT-TYPE (no object page) |
| ZTE-AN-GPON-REMOTE-ONU-MIB | zxAnGponRemoteOnuMib zxAnGponRmAniLaserBiasCurrent zxAnGponRmAniLowerRxOptThresh zxAnGponRmAniLowerTxOptThresh zxAnGponRmAniSdThresh zxAnGponRmAniSfThresh zxAnGponRmAniUpperRxOptThresh zxAnGponRmAniUpperTxOptThresh zxAnGponRmCesUniExpectedType zxAnGponRmEthUniExpectedType zxAnGponRmOnuSerialNum |
| ZTE-AN-GPON-SERVICE-MIB | zxAnGponOnuMgmtDesc zxAnGponOnuMgmtName zxAnGponOnuMgmtRegistrationInfo zxAnGponOnuMgmtTypeName |
| ZTE-AN-PON-PROTECTION-MIB | zxAnPonProtectGroupName |
Net-SNMP examples using the zte-ng MIB directory Show commands
These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.
Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'ZTE-AN-GPON-REMOTE-ONU-TRAP-MIB' -M '/opt/observium/mibs/zte-ng:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'ZTE-AN-GPON-REMOTE-ONU-TRAP-MIB::zxAnGponRmOnuNotifications'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ZTE-AN-GPON-REMOTE-ONU-TRAP-MIB' -M '/opt/observium/mibs/zte-ng:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ZTE-AN-GPON-REMOTE-ONU-TRAP-MIB::zxAnGponRmOnuNotifications'
Objects (2)
Showing 2 of 2 objects
Object legend
Object type
Icons distinguish tables, entry rows, columns, scalars, and structural nodes.
SNMPv2-TCTruthValue
Syntax
Blue badges identify the value syntax. Connected badges read as defining module and convention.
IF-MIBifIndex
Table index
Green identifies an index object; yellow names its module when the index is defined elsewhere.
r/w
deprecated
obsolete
Access and status
r/w means read-write. Grey labels mark definitions retained for compatibility.
OBS ✓
Observium use
The indicator appears only when Observium directly references that object.
ifOperStatus
.1.3.6.1.2.1…
Names and OIDs
Object names link to their detail pages. Hover or focus a linked name or badge for available definition details.
.1.3.6.1.4.1.3902.1082.500.20.3 |
||
.1.3.6.1.4.1.3902.1082.500.20.3.1 |
Dependencies (18) 5 direct · 13 transitive Show tree and compile order Hide dependency details
Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.
Dependency tree
Dependency-first compile order
- SNMPv2-SMIrfc
- SNMPv2-CONFrfc
- SNMPv2-TCrfc
- IANAifType-MIBrfc
- SNMPv2-MIBrfc
- IF-MIBrfc
- INET-ADDRESS-MIBrfc
- ZTE-AN-SMIzte-ng
- ZTE-AN-TC-MIBzte-ng
- ZTE-AN-IF-MIBzte-ng
- ZTE-AN-PON-TC-MIBzte-ng
- ZTE-AN-PON-BASE-MIBzte-ng
- VDSL2-LINE-TC-MIBrfc
- ZTE-AN-PON-REMOTE-ONU-MIBzte-ng
- ZTE-AN-GPON-REMOTE-ONU-MIBzte-ng
- HC-PerfHist-TC-MIBrfc
- ZTE-AN-PON-PROTECTION-MIBzte-ng
- ZTE-AN-GPON-SERVICE-MIBzte-ng
- ZTE-AN-GPON-REMOTE-ONU-TRAP-MIBzte-ngselected
Notifications / Traps (62)
| Name | OID | Description |
|---|---|---|
.1.3.6.1.4.1.3902.1082.500.20.3.1.1 |
No carrier at the Ethernet UNI
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.100 |
A zxAnGponRmOnuEsmcMsgLostClr trap is sent when the agent has
detected that the ESMC messages are received again. |
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.101 |
A zxAnGponRmOnuTimeLossOfLockAlm trap is sent when the ONU has
detected that the time was in the loss of lock status. |
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.102 |
A zxAnGponRmOnuTimeLossOfLockClr trap is sent when the ONU has
detected that the time has been locked again. |
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.123 |
Received downstream optical power below threshold.
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.124 |
Received downstream optical power below threshold.
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.125 |
Received downstream optical power above threshold.
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.126 |
Received downstream optical power above threshold.
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.127 |
Bit error-based signal fail. Industry practice normally
expects the BER to improve by at least an order of magnitude before clearing the alarm. |
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.128 |
Bit error-based signal fail. Industry practice normally
expects the BER to improve by at least an order of magnitude before clearing the alarm. |
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.129 |
Bit error-based signal degrade. Industry practice normally
expects the BER to improve by at least an order of magnitude before clearing the alarm. |
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.130 |
Bit error-based signal degrade. Industry practice normally
expects the BER to improve by at least an order of magnitude before clearing the alarm. |
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.131 |
Transmit optical power below lower threshold.
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.132 |
Transmit optical power below lower threshold.
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.133 |
Transmit optical power above upper threshold.
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.134 |
Transmit optical power above upper threshold.
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.135 |
Laser bias current above threshold determined by vendor.
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.136 |
Laser bias current above threshold
determined by vendor. |
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.169 |
High Cpu Usage
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.170 |
High Cpu Usage
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.171 |
High Memory Usage
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.172 |
High Memory Usage
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.2 |
No carrier at the Ethernet UNI
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.200 |
Loss of signal at the CES UNI
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.201 |
Loss of signal cleared at the CES UNI
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.202 |
34.368 Mbit/s alarm indication signal at the CES UNI
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.203 |
34.368 Mbit/s alarm indication signal cleared at the CES UNI
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.204 |
2.048 Mbit/s alarm indication signal at the CES UNI
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.205 |
2.048 Mbit/s alarm indication signal cleared at the CES UNI
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.206 |
1.544 Mbit/s alarm indication signal at the CES UNI
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.207 |
1.544 Mbit/s alarm indication signal cleared at the CES UNI
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.208 |
44.736 Mbit/s alarm indication signal at the CES UNI
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.209 |
44.736 Mbit/s alarm indication signal cleared at the CES UNI
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.3 |
ONU detects a loop at the Ethernet UNI
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.4 |
ONU detects a loop at the Ethernet UNI
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.73 |
Functional failure on an internal interface
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.74 |
Functional failure on an internal interface
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.75 |
Loss of external power to battery backup unit.
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.76 |
Loss of external power to battery backup unit.
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.77 |
Battery is provisioned but missing
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.78 |
Battery is provisioned but missing
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.79 |
Battery is provisioned and present but cannot recharge
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.80 |
Battery is provisioned and present but cannot recharge
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.81 |
Battery is provisioned and present but its voltage is too low
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.82 |
Battery is provisioned and present but its voltage is too low
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.83 |
Applies if the ONU supports detection such as door or box open
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.84 |
Applies if the ONU supports detection such as door or box open
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.85 |
ONU has failed autonomous self test
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.86 |
ONU has failed autonomous self test
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.87 |
ONU is powering off imminently due to loss of power to the ONU
itself. |
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.88 |
ONU is powering off imminently due to loss of power to the ONU
itself. |
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.89 |
Temperature yellow.
No service shutdown at present, but the circuit pack is operating beyond its recommended range. |
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.90 |
Temperature yellow.
No service shutdown at present, but the circuit pack is operating beyond its recommended range. |
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.91 |
Temperature red.
Some services have been shut down to avoid equipment damage. |
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.92 |
Temperature red.
Some services have been shut down to avoid equipment damage. |
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.93 |
No service shutdown at present, but the line power voltage
is below its recommended minimum. |
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.94 |
No service shutdown at present, but the line power voltage
is below its recommended minimum. |
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.95 |
Some services have been shut down to avoid power collapse.
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.96 |
Some services have been shut down to avoid power collapse.
|
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.97 |
A zxAnGponRmOnuClockLossOfLockAlm trap is sent when the ONU has
detected that the clock was in the loss of lock status. |
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.98 |
A zxAnGponRmOnuClockLossOfLockClr trap is sent when the ONU has
detected that the clock has been locked again. |
|
.1.3.6.1.4.1.3902.1082.500.20.3.1.99 |
A zxAnGponRmOnuEsmcMsgLostAlm trap is sent when the ONU has
detected that the ESMC messages lost. |