ZHONE-GEN-INTERFACE-CONFIG-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
1
Rows
1
Columns
7
alarmConfigTable
table.1.3.6.1.4.1.5504.3.13.1.1
·
1 row entry
·
7 columns
Uses the zhone variant from
Command help
/opt/observium/mibs/zhone.
Walk alarmConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ZHONE-GEN-INTERFACE-CONFIG-MIB' -M '/opt/observium/mibs/zhone:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ZHONE-GEN-INTERFACE-CONFIG-MIB::alarmConfigTable'
The alarm configuration table
An entry in the alarm configuration table.
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
This field describes the enable status of the
Bit Rate Threshold Alarm. If this field is true (1) then the Bit Rate Threshold alarm is enabled. If this field is false (2) then the Bit Rate Threshold Alarm is disab… |
SNMPv2-TCTruthValuer/w Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.5504.3.13.1.1.1.1 |
||||||||
|
This field indicates the Bit Rate Threshold
Value which will generate an alarm if the Bit Rate Threshold Alarm is enabled and the Bit Rate of this ifIndex drops below this value. |
SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.5504.3.13.1.1.1.2 |
||||||||
|
This field indicates the Bit Rate Threshold
Holdtime in seconds for which the Bit Rate of the ifIndex must remain below the Bit Rate Threshold Value before an alarm will be generated if the Bit Rate Threshold Alarm i… |
SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.5504.3.13.1.1.1.3 |
||||||||
|
This field describes the enable status of the
Status Trap Alarm. If this field is true (1) then the Status Trap alarm is enabled. If this field is false (2) then the Status Trap Alarm is disabled. |
SNMPv2-TCTruthValuer/w Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.5504.3.13.1.1.1.4 |
||||||||
|
This field describes the enable status of the
Admin Up Alarm. If this field is true (1) then the Admin Up alarm is enabled. If this field is false (2) then the Admin Up Alarm is disabled. |
SNMPv2-TCTruthValuer/w Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.5504.3.13.1.1.1.5 |
||||||||
|
This object is used to override Trap, Central Alarm Manager and CLI 'LineAlarm' severity levels for the specified interface.
|
Zhone-TCZhoneAlarmSeverityr/w Type Values:
|
.1.3.6.1.4.1.5504.3.13.1.1.1.6 |
||||||||
|
This object is used to create, delete or modify a row in this table.
|
Zhone-TCZhoneRowStatusr/w Type Values:
|
.1.3.6.1.4.1.5504.3.13.1.1.1.7 |