Webio-ANx-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
18
Rows
18
Columns
90

wtWebioAn8SensorTable

table mandatory
.1.3.6.1.4.1.5040.1.2.1.1.2 · 1 row entry · 1 columns
Uses the webgraph variant from /opt/observium/mibs/webgraph.
Command help
Walk wtWebioAn8SensorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Webio-ANx-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Webio-ANx-MIB::wtWebioAn8SensorTable'
List of sensors.
wtWebioAn8SensorEntry row .1.3.6.1.4.1.5040.1.2.1.1.2.1
Temperature sensor numbers.
Column Syntax OID
Temperature sensor number.
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.5040.1.2.1.1.2.1.1

wtWebioAn8TempValueTable

table mandatory
.1.3.6.1.4.1.5040.1.2.1.1.3 · 1 row entry · 1 columns
Uses the webgraph variant from /opt/observium/mibs/webgraph.
Command help
Walk wtWebioAn8TempValueTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Webio-ANx-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Webio-ANx-MIB::wtWebioAn8TempValueTable'
List of temperature values corresponding to the channel numbers.
wtWebioAn8TempValueEntry row .1.3.6.1.4.1.5040.1.2.1.1.3.1
Temperatures of the sensors.
Column Syntax OID
Temperature value of the sensor, ASCII, 5 characters in length.
OctetString
Constraints:
range: 5-5
.1.3.6.1.4.1.5040.1.2.1.1.3.1.1
.1.3.6.1.4.1.5040.1.2.1.1.4 · 1 row entry · 1 columns
Uses the webgraph variant from /opt/observium/mibs/webgraph.
Command help
Walk wtWebioAn8BinaryTempValueTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Webio-ANx-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Webio-ANx-MIB::wtWebioAn8BinaryTempValueTable'
List of binary temperature values corresponding to the channel numbers.
wtWebioAn8BinaryTempValueEntry row .1.3.6.1.4.1.5040.1.2.1.1.4.1
Binary temperature values of the sensors.
Column Syntax OID
Binary temperature value of the sensor in 1/10 degrees Celsius,
signed number, 0x7FFF indicates an
invalid measured value.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.1.1.4.1.1

wtWebioAn8AlarmIfTable

table mandatory
.1.3.6.1.4.1.5040.1.2.1.3.1.5.2 · 1 row entry · 1 columns
Uses the webgraph variant from /opt/observium/mibs/webgraph.
Command help
Walk wtWebioAn8AlarmIfTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Webio-ANx-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Webio-ANx-MIB::wtWebioAn8AlarmIfTable'
List of alarm indices.
wtWebioAn8AlarmIfEntry row .1.3.6.1.4.1.5040.1.2.1.3.1.5.2.1
Numbers of the alarms.
Column Syntax OID
Alarm number.
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.5040.1.2.1.3.1.5.2.1.1

wtWebioAn8AlarmTable

table mandatory
.1.3.6.1.4.1.5040.1.2.1.3.1.5.3 · 1 row entry · 19 columns
Uses the webgraph variant from /opt/observium/mibs/webgraph.
Command help
Walk wtWebioAn8AlarmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Webio-ANx-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Webio-ANx-MIB::wtWebioAn8AlarmTable'
List of settings depending on the alarm number.
wtWebioAn8AlarmEntry row .1.3.6.1.4.1.5040.1.2.1.3.1.5.3.1
Alarm parameters of the individual alarms.
Column Syntax OID
Binary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3:
Bit 0: Timer
Bit 1: ColdStart
Bit 2: WarmStart

Octet 4:
Bit 0: Sensor 1
Bit 1: Sensor 2
Bit 2: Sensor 3
Bit 3: Sensor 4
B…
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.1.3.1.5.3.1.1
Minimum temperature in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.1.3.1.5.3.1.2
Maximum temperature in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.1.3.1.5.3.1.3
Send interval for alarm messages.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.1.3.1.5.3.1.4
Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Mail Enable
Bit 1: SNMP Trap enable
Bit 2: TCP Client enable
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.1.3.1.5.3.1.5
E-Mail address for sending the alarm mail to.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.1.3.1.5.3.1.6
Subject line for alarm mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.1.3.1.5.3.1.7
Alarm mail text: <Tn> provides the current temperature; n = 1..8.
<Z> provides the current time.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.1.3.1.5.3.1.8
Name or IP address of the SNMP Manager which accepts the trap.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.1.3.1.5.3.1.9
This text is sent in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.1.3.1.5.3.1.10
Binary coded options:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Attach Thermo.csv Enable
Bit 1-7: unused
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.1.3.1.5.3.1.11
Name or IP address of the TCP server which accepts the trap.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.1.3.1.5.3.1.12
Port number of the TCP server which accepts the trap.
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.1.3.1.5.3.1.13
This text is sent in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.1.3.1.5.3.1.14
Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.)
, in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.1.3.1.5.3.1.15
Subject line for alarm clear mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.1.3.1.5.3.1.16
Alarm clear mail text: <Tn> provides the current temperature; n = 1..8.
<Z> provides the current time.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.1.3.1.5.3.1.17
This text is sent in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.1.3.1.5.3.1.18
This text is sent in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.1.3.1.5.3.1.19

wtWebioAn8PortTable

table mandatory
.1.3.6.1.4.1.5040.1.2.1.3.2.1 · 1 row entry · 7 columns
Uses the webgraph variant from /opt/observium/mibs/webgraph.
Command help
Walk wtWebioAn8PortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Webio-ANx-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Webio-ANx-MIB::wtWebioAn8PortTable'
List of settings depending on the sensor number.
wtWebioAn8PortEntry row .1.3.6.1.4.1.5040.1.2.1.3.2.1.1
Sensor parameters for the individual sensors.
Column Syntax OID
Name of the sensor.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.1.3.2.1.1.1
Description of the sensor.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.1.3.2.1.1.2
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.1.3.2.1.1.3
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.1.3.2.1.1.4
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.1.3.2.1.1.5
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.1.3.2.1.1.6
Offset calibration: informations of date, name of operator, reference devices.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.1.3.2.1.1.7

wtWebioAn2SensorTable

table mandatory
.1.3.6.1.4.1.5040.1.2.2.1.2 · 1 row entry · 1 columns
Uses the webgraph variant from /opt/observium/mibs/webgraph.
Command help
Walk wtWebioAn2SensorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Webio-ANx-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Webio-ANx-MIB::wtWebioAn2SensorTable'
List of Sensors.
wtWebioAn2SensorEntry row .1.3.6.1.4.1.5040.1.2.2.1.2.1
Temperature sensor numbers.
Column Syntax OID
Temperature sensor number.
Integer32
Constraints:
range: 1-2
.1.3.6.1.4.1.5040.1.2.2.1.2.1.1

wtWebioAn2TempValueTable

table mandatory
.1.3.6.1.4.1.5040.1.2.2.1.3 · 1 row entry · 1 columns
Uses the webgraph variant from /opt/observium/mibs/webgraph.
Command help
Walk wtWebioAn2TempValueTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Webio-ANx-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Webio-ANx-MIB::wtWebioAn2TempValueTable'
List of temperature values corresponding to the channel numbers.
wtWebioAn2TempValueEntry row .1.3.6.1.4.1.5040.1.2.2.1.3.1
Temperatures of the sensors.
Column Syntax OID
Temperature value of the sensor, ASCII, 5 characters in length.
OctetString
Constraints:
range: 5-5
.1.3.6.1.4.1.5040.1.2.2.1.3.1.1
.1.3.6.1.4.1.5040.1.2.2.1.4 · 1 row entry · 1 columns
Uses the webgraph variant from /opt/observium/mibs/webgraph.
Command help
Walk wtWebioAn2BinaryTempValueTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Webio-ANx-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Webio-ANx-MIB::wtWebioAn2BinaryTempValueTable'
List of binary temperature values corresponding to the channel numbers.
wtWebioAn2BinaryTempValueEntry row .1.3.6.1.4.1.5040.1.2.2.1.4.1
Binary temperature values of the sensors.
Column Syntax OID
Binary temperature value of the sensor in 1/10 degrees Celsius,
signed number, 0x7FFF indicates an
invalid measured value.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.2.1.4.1.1

wtWebioAn2AlarmIfTable

table mandatory
.1.3.6.1.4.1.5040.1.2.2.3.1.5.2 · 1 row entry · 1 columns
Uses the webgraph variant from /opt/observium/mibs/webgraph.
Command help
Walk wtWebioAn2AlarmIfTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Webio-ANx-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Webio-ANx-MIB::wtWebioAn2AlarmIfTable'
List of alarm indices.
wtWebioAn2AlarmIfEntry row .1.3.6.1.4.1.5040.1.2.2.3.1.5.2.1
Numbers of the alarms.
Column Syntax OID
Alarm number.
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.5040.1.2.2.3.1.5.2.1.1

wtWebioAn2AlarmTable

table mandatory
.1.3.6.1.4.1.5040.1.2.2.3.1.5.3 · 1 row entry · 19 columns
Uses the webgraph variant from /opt/observium/mibs/webgraph.
Command help
Walk wtWebioAn2AlarmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Webio-ANx-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Webio-ANx-MIB::wtWebioAn2AlarmTable'
List of settings depending on the alarm number.
wtWebioAn2AlarmEntry row .1.3.6.1.4.1.5040.1.2.2.3.1.5.3.1
Alarm parameters of the individual alarms.
Column Syntax OID
Binary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Sensor 1
Bit 1: Sensor 2
Bit 2: Timer
Bit 1: ColdStart
Bit 2: WarmStart
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.2.3.1.5.3.1.1
Minimum temperature in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.2.3.1.5.3.1.2
Maximum temperature in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.2.3.1.5.3.1.3
Send interval for alarm messages.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.2.3.1.5.3.1.4
Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Mail Enable
Bit 1: SNMP Trap enable
Bit 2: TCP Client enable
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.2.3.1.5.3.1.5
E-Mail address for sending the alarm mail to.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.2.3.1.5.3.1.6
Subject line for alarm mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.2.3.1.5.3.1.7
Alarm mail text: <Tn> provides the current temperature; n = 1..2.
<Z> provides the current time.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.2.3.1.5.3.1.8
Name or IP address of the SNMP Manager which accepts the trap.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.2.3.1.5.3.1.9
This text is sent in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.2.3.1.5.3.1.10
Binary coded options:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Attach Thermo.csv Enable
Bit 1-7: unused
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.2.3.1.5.3.1.11
Name or IP address of the TCP server which accepts the trap.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.2.3.1.5.3.1.12
Port number of the TCP server which accepts the trap.
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.2.3.1.5.3.1.13
This text is sent in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.2.3.1.5.3.1.14
Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.)
, in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.2.3.1.5.3.1.15
Subject line for alarm clear mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.2.3.1.5.3.1.16
Alarm clear mail text: <Tn> provides the current temperature; n = 1..8.
<Z> provides the current time.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.2.3.1.5.3.1.17
This text is sent in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.2.3.1.5.3.1.18
This text is sent in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.2.3.1.5.3.1.19

wtWebioAn2PortTable

table mandatory
.1.3.6.1.4.1.5040.1.2.2.3.2.1 · 1 row entry · 7 columns
Uses the webgraph variant from /opt/observium/mibs/webgraph.
Command help
Walk wtWebioAn2PortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Webio-ANx-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Webio-ANx-MIB::wtWebioAn2PortTable'
List of settings depending on the sensor number.
wtWebioAn2PortEntry row .1.3.6.1.4.1.5040.1.2.2.3.2.1.1
Sensor parameters for the individual sensor.
Column Syntax OID
Name of the sensor.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.2.3.2.1.1.1
Description of the sensor.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.2.3.2.1.1.2
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.2.3.2.1.1.3
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.2.3.2.1.1.4
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.2.3.2.1.1.5
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.2.3.2.1.1.6
Offset calibration: informations of date, name of operator, reference devices.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.2.3.2.1.1.7

wtWebioAn1SensorTable

table mandatory
.1.3.6.1.4.1.5040.1.2.3.1.2 · 1 row entry · 1 columns
Uses the webgraph variant from /opt/observium/mibs/webgraph.
Command help
Walk wtWebioAn1SensorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Webio-ANx-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Webio-ANx-MIB::wtWebioAn1SensorTable'
List of sensors.
wtWebioAn1SensorEntry row .1.3.6.1.4.1.5040.1.2.3.1.2.1
Temperature sensor numbers.
Column Syntax OID
Temperature sensor number.
Integer32
Constraints:
range: 1-1
.1.3.6.1.4.1.5040.1.2.3.1.2.1.1

wtWebioAn1TempValueTable

table mandatory
.1.3.6.1.4.1.5040.1.2.3.1.3 · 1 row entry · 1 columns
Uses the webgraph variant from /opt/observium/mibs/webgraph.
Command help
Walk wtWebioAn1TempValueTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Webio-ANx-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Webio-ANx-MIB::wtWebioAn1TempValueTable'
List of temperature values corresponding to the channel numbers.
wtWebioAn1TempValueEntry row .1.3.6.1.4.1.5040.1.2.3.1.3.1
Temperatures of the sensors.
Column Syntax OID
Temperature value of the sensor, ASCII, 5 characters in length.
OctetString
Constraints:
range: 5-5
.1.3.6.1.4.1.5040.1.2.3.1.3.1.1
.1.3.6.1.4.1.5040.1.2.3.1.4 · 1 row entry · 1 columns
Uses the webgraph variant from /opt/observium/mibs/webgraph.
Command help
Walk wtWebioAn1BinaryTempValueTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Webio-ANx-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Webio-ANx-MIB::wtWebioAn1BinaryTempValueTable'
List of binary temperature values corresponding to the channel numbers.
wtWebioAn1BinaryTempValueEntry row .1.3.6.1.4.1.5040.1.2.3.1.4.1
Binary temperature values of the sensors.
Column Syntax OID
Binary temperature value of the sensor in 1/10 degrees Celsius,
signed number, 0x7FFF indicates an
invalid measured value.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.5040.1.2.3.1.4.1.1

wtWebioAn1AlarmIfTable

table mandatory
.1.3.6.1.4.1.5040.1.2.3.3.1.5.2 · 1 row entry · 1 columns
Uses the webgraph variant from /opt/observium/mibs/webgraph.
Command help
Walk wtWebioAn1AlarmIfTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Webio-ANx-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Webio-ANx-MIB::wtWebioAn1AlarmIfTable'
List of alarm indices.
wtWebioAn1AlarmIfEntry row .1.3.6.1.4.1.5040.1.2.3.3.1.5.2.1
Numbers of the alarms.
Column Syntax OID
Alarm number.
Integer32
Constraints:
range: 1-8
.1.3.6.1.4.1.5040.1.2.3.3.1.5.2.1.1

wtWebioAn1AlarmTable

table mandatory
.1.3.6.1.4.1.5040.1.2.3.3.1.5.3 · 1 row entry · 19 columns
Uses the webgraph variant from /opt/observium/mibs/webgraph.
Command help
Walk wtWebioAn1AlarmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Webio-ANx-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Webio-ANx-MIB::wtWebioAn1AlarmTable'
List of settings depending on the alarm number.
wtWebioAn1AlarmEntry row .1.3.6.1.4.1.5040.1.2.3.3.1.5.3.1
Alarm parameters of the individual alarms.
Column Syntax OID
Binary coded trigger condition:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Sensor 1
Bit 1: Timer
Bit 2: ColdStart
Bit 3: WarmStart
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.3.3.1.5.3.1.1
Minimum temperature in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.3.3.1.5.3.1.2
Maximum temperature in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.3.3.1.5.3.1.3
Send interval for alarm messages.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.3.3.1.5.3.1.4
Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Mail Enable
Bit 1: SNMP Trap enable
Bit 2: TCP Client enable
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.3.3.1.5.3.1.5
E-Mail address for sending the alarm mail to.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.3.3.1.5.3.1.6
Subject line for alarm mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.3.3.1.5.3.1.7
Alarm mail text: <T1> provides the current temperature.
<Z> provides the current time.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.3.3.1.5.3.1.8
Name or IP address of the SNMP Manager which accepts the trap.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.3.3.1.5.3.1.9
This text is sent in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.3.3.1.5.3.1.10
Binary coded options:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Attach Thermo.csv Enable
Bit 1-7: unused
OctetStringr/w
Constraints:
range: 4-4
.1.3.6.1.4.1.5040.1.2.3.3.1.5.3.1.11
Name or IP address of the TCP server which accepts the trap.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.3.3.1.5.3.1.12
Port number of the TCP server which accepts the trap.
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5040.1.2.3.3.1.5.3.1.13
This text is sent in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.3.3.1.5.3.1.14
Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.)
, in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.3.3.1.5.3.1.15
Subject line for alarm clear mail.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.3.3.1.5.3.1.16
Alarm clear mail text: <Tn> provides the current temperature; n = 1..8.
<Z> provides the current time.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.3.3.1.5.3.1.17
This text is sent in the trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.3.3.1.5.3.1.18
This text is sent in the TCP trap body.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.3.3.1.5.3.1.19

wtWebioAn1PortTable

table mandatory
.1.3.6.1.4.1.5040.1.2.3.3.2.1 · 1 row entry · 7 columns
Uses the webgraph variant from /opt/observium/mibs/webgraph.
Command help
Walk wtWebioAn1PortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Webio-ANx-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Webio-ANx-MIB::wtWebioAn1PortTable'
List of settings depending on the sensor number.
wtWebioAn1PortEntry row .1.3.6.1.4.1.5040.1.2.3.3.2.1.1
Sensor parameters for the individual sensors.
Column Syntax OID
Name of the sensor.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.3.3.2.1.1.1
Description of the sensor.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.3.3.2.1.1.2
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.3.3.2.1.1.3
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.3.3.2.1.1.4
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.3.3.2.1.1.5
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.3.3.2.1.1.6
Offset calibration: informations of date, name of operator, reference devices.
OctetStringr/w .1.3.6.1.4.1.5040.1.2.3.3.2.1.1.7