WebGraph-AnalogIO-57662-US-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
12
Rows
12
Columns
110
.1.3.6.1.4.1.5040.1.2.29.1.2
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebGraphAnalog57662SensorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-AnalogIO-57662-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-AnalogIO-57662-US-MIB::wtWebGraphAnalog57662SensorTable'
List of sensors.
List of sensor numbers.
Indexes
| Column | Syntax | OID |
|---|---|---|
wtWebGraphAnalog57662SensorNomandatory Sensor number. | Integer32 Constraints: range: 1-2 | .1.3.6.1.4.1.5040.1.2.29.1.2.1.1 |
.1.3.6.1.4.1.5040.1.2.29.1.3
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebGraphAnalog57662ValuesTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-AnalogIO-57662-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-AnalogIO-57662-US-MIB::wtWebGraphAnalog57662ValuesTable'
List of measurement values corresponding to the channel numbers.
Measurement values of the sensors.
Indexes
| Column | Syntax | OID |
|---|---|---|
wtWebGraphAnalog57662Valuesmandatory Measurement value of the sensor, ASCII.This value will be translated according to the ports settings for the read and write operations. | OctetStringr/w Constraints: range: 5-5 | .1.3.6.1.4.1.5040.1.2.29.1.3.1.1 |
.1.3.6.1.4.1.5040.1.2.29.1.4
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebGraphAnalog57662BinaryValuesTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-AnalogIO-57662-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-AnalogIO-57662-US-MIB::wtWebGraphAnalog57662BinaryValuesTable'
List of binary measurement values corresponding to the channel numbers.
Binary measurement values of the sensors.
Indexes
| Column | Syntax | OID |
|---|---|---|
wtWebGraphAnalog57662BinaryValuesmandatory Binary measurement value of the sensor in 1/1000,signed number, 0x7FFFFFFF indicates an invalid value. This value will be translated according to the ports settings for the read and write operations. | Integer32r/w Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.5040.1.2.29.1.4.1.1 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.2
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebGraphAnalog57662BinaryIfTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-AnalogIO-57662-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-AnalogIO-57662-US-MIB::wtWebGraphAnalog57662BinaryIfTable'
Table of indices.
Indices of the binary channels.
| Column | Syntax | OID |
|---|---|---|
wtWebGraphAnalog57662BinaryModeNomandatory Number of the binary channel. | Integer32 Constraints: range: 1-2 | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.2.1.1 |
.1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3
·
1 row entry
·
28 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebGraphAnalog57662BinaryTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-AnalogIO-57662-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-AnalogIO-57662-US-MIB::wtWebGraphAnalog57662BinaryTable'
Table of properties of the binary mode.
Binary properties.
| Column | Syntax | OID |
|---|---|---|
| Selection of the operation mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : UDP Peer Bit 1 : TCP Client … | OctetStringr/w Constraints: range: 4-4 | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.1 |
| Local TCP port for data exchange in this server mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual). | Integer32r/w Constraints: range: 1-65535 | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.2 |
| Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input … | OctetStringr/w Constraints: range: 4-4 | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.3 |
| Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 4-7: unused Bit 3 : OPC Device Bit 2 : Box2Box S… | OctetStringr/w Constraints: range: 4-4 | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.4 |
| Local TCP port for data exchange in this client mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual). | Integer32r/w Constraints: range: 1-65535 | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.5 |
| Port number of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server port to zero. | Integer32r/w Constraints: range: 1-65535 | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.6 |
| Ip address of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server IP address to 0.0.0.0. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.7 |
| Building a connection may be protected by the administrator password of the server. Enter the server password to establish the connection, if a server administrator password exists. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.8 |
| Connection timeout in 100ms. If no data are exchanged within the specified time, the device closes the connection to the server. The value 0 deactivates the timer. Using the Box2Box mode this function is disabled. | Integer32r/w Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.9 |
| Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input … | OctetStringr/w Constraints: range: 4-4 | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.10 |
| Configurable interval with a 100ms base, in which the Webio device sends data to the configured application. A interval of zero stopps the periodical sending. | Integer32r/w Constraints: range: 0-65535 | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.11 |
| Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compat… | OctetStringr/w Constraints: range: 4-4 | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.12 |
| Local UDP port for data exchange in this peer to peer mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual). | Integer32r/w Constraints: range: 1-65535 | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.13 |
| Port number of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote port to zero. | Integer32r/w Constraints: range: 1-65535 | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.14 |
| Ip address of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote device IP address to 0.0.0.0. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.15 |
| Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input … | OctetStringr/w Constraints: range: 4-4 | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.16 |
| Configurable interval with a 100ms base, in which the Webio device sends data to the configured remote device. A interval of zero stopps the periodical sending. | Integer32r/w Constraints: range: 0-65535 | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.17 |
| Selection of the application mode: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused… | OctetStringr/w Constraints: range: 4-4 | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.18 |
| Port number of the remote device, after connection has been established. In case of no connection or missing port informations a zero will be read. | Integer32 Constraints: range: 1-65535 | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.19 |
| IP address of the remote device, after connection has been established. In case of no connection or missing port informations 0.0.0.0 will be read. | RFC1155-SMIIpAddress Type Constraints: range: 4 | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.20 |
| HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs status informations will be send to this port. Not used at mode Compatible 50xxx. | Integer32r/w Constraints: range: 1-65535 | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.21 |
| HTTP port number of the remote device at TCP Client Mode. In the operating mode Box2Box connection status informations will be exchanged through this port. | Integer32r/w Constraints: range: 1-65535 | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.22 |
| A change greater than this value initiate a transmission of the corresponding input value. The input 1 must be selected at wtWebGraphAnalog57662BinaryTcpServerInputTrigger. With a hysteresis of zero any change will be t… | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.23 |
| A change greater than this value initiate a transmission of the corresponding input value. The input 2 must be selected at wtWebGraphAnalog57662BinaryTcpServerInputTrigger. With a hysteresis of zero any change will be t… | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.24 |
| A change greater than this value initiate a transmission of the corresponding input value. The input 1 must be selected at wtWebGraphAnalog57662BinaryTcpClientInputTrigger. With a hysteresis of zero any change will be t… | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.25 |
| A change greater than this value initiate a transmission of the corresponding input value. The input 2 must be selected at wtWebGraphAnalog57662BinaryTcpClientInputTrigger. With a hysteresis of zero any change will be t… | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.26 |
| A change greater than this value initiate a transmission of the corresponding input value. The input 1 must be selected at wtWebGraphAnalog57662BinaryUdpPeerInputTrigger. With a hysteresis of zero any change will be tra… | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.27 |
| A change greater than this value initiate a transmission of the corresponding input value. The input 2 must be selected at wtWebGraphAnalog57662BinaryUdpPeerInputTrigger. With a hysteresis of zero any change will be tra… | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.3.9.3.1.28 |
.1.3.6.1.4.1.5040.1.2.29.3.1.4.4
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebGraphAnalog57662SensorColorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-AnalogIO-57662-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-AnalogIO-57662-US-MIB::wtWebGraphAnalog57662SensorColorTable'
List of sensor colors for the praphical presentation.
Index numbers of the sensors.
Indexes
| Column | Syntax | OID |
|---|---|---|
wtWebGraphAnalog57662SensorColormandatory Color of the sensors at the praphical presention. | OctetStringr/w Constraints: range: 3-3 | .1.3.6.1.4.1.5040.1.2.29.3.1.4.4.1.1 |
.1.3.6.1.4.1.5040.1.2.29.3.1.5.2
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebGraphAnalog57662AlarmIfTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-AnalogIO-57662-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-AnalogIO-57662-US-MIB::wtWebGraphAnalog57662AlarmIfTable'
List of alarm indices.
Numbers of the alarms.
Indexes
| Column | Syntax | OID |
|---|---|---|
wtWebGraphAnalog57662AlarmNomandatory Alarm number. | Integer32 Constraints: range: 1-8 | .1.3.6.1.4.1.5040.1.2.29.3.1.5.2.1.1 |
.1.3.6.1.4.1.5040.1.2.29.3.1.5.3
·
1 row entry
·
33 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebGraphAnalog57662AlarmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-AnalogIO-57662-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-AnalogIO-57662-US-MIB::wtWebGraphAnalog57662AlarmTable'
List of settings depending on the alarm number.
Alarm parameters of the individual alarms.
Indexes
| Column | Syntax | OID |
|---|---|---|
wtWebGraphAnalog57662AlarmTriggermandatory Binary coded trigger conditions:Octet 1: unused Octet 2: unused Octet 3: Bit 0: Timer Bit 1: ColdStart Bit 2: WarmStart Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused | OctetStringr/w Constraints: range: 4-4 | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.1 |
wtWebGraphAnalog57662AlarmMin1mandatory Minimum sensor 1 with maximum 3 decimal places. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.2 |
wtWebGraphAnalog57662AlarmMax1mandatory Maximum sensor 1 with maximum 3 decimal places. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.3 |
| Reading changes of this size clears the alarm state (MAX-hyst, MIN+hyst.) with maximum 3 decimal places. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.4 |
wtWebGraphAnalog57662AlarmDelaymandatory Alarm will be delayed by setting this time while stable alarm condition occur (time in minutes). | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.5 |
wtWebGraphAnalog57662AlarmIntervalmandatory Send interval for alarm messages. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.6 |
wtWebGraphAnalog57662AlarmEnablemandatory Binary coded alarm enable:Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable | OctetStringr/w Constraints: range: 4-4 | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.7 |
wtWebGraphAnalog57662AlarmEMailAddrmandatory E-Mail address for sending the alarm mail to. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.8 |
| Subject line for alarm mail. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.9 |
wtWebGraphAnalog57662AlarmMailTextmandatory Alarm mail text: <Mn> provides the current temperature; n = 1..2.<Z> provides the current time. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.10 |
wtWebGraphAnalog57662AlarmManagerIPmandatory Name or IP address of the SNMP Manager which accepts the trap. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.11 |
wtWebGraphAnalog57662AlarmTrapTextmandatory This text is sent in the trap body. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.12 |
| Binary coded options: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Thermo.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: unused | OctetStringr/w Constraints: range: 4-4 | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.13 |
wtWebGraphAnalog57662AlarmTcpIpAddrmandatory Name or IP address of the TCP server which accepts the trap. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.14 |
wtWebGraphAnalog57662AlarmTcpPortmandatory Port number of the TCP server which accepts the trap. | Integer32r/w Constraints: range: 1-65535 | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.15 |
wtWebGraphAnalog57662AlarmTcpTextmandatory This text is sent in the TCP trap body. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.16 |
| Subject line for alarm clear mail. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.17 |
| Alarm clear mail text: <Mn> provides the current temperature; n = 1..2. <Z> provides the current time. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.18 |
| This text is sent in the trap body. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.19 |
| This text is sent in the TCP trap body. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.20 |
wtWebGraphAnalog57662AlarmMin2mandatory Minimum sensor 2 with maximum 3 decimal places. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.21 |
wtWebGraphAnalog57662AlarmMax2mandatory Maximum sensor 2 with maximum 2 decimal places. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.22 |
| Hysterese rel. sensor 2 with maximum 3 decimal places. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.23 |
| IP address of the syslog server to which the Webio device should send syslog messages. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.24 |
wtWebGraphAnalog57662AlarmSyslogPortmandatory Port number of the syslog server to which the Webio device should send syslog messages. | Integer32r/w Constraints: range: 1-65535 | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.25 |
wtWebGraphAnalog57662AlarmSyslogTextmandatory Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.This text appears in the following syslog message body. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.26 |
| Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body of a alarm clear message. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.27 |
| Local data port: 1..65535 or AUTO: the next free port will be assigned. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.28 |
| Name of the file including path informations. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.29 |
wtWebGraphAnalog57662AlarmFtpTextmandatory Message text to store on the FTP server. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.30 |
| Alarm clear message to store on the FTP server. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.31 |
wtWebGraphAnalog57662AlarmFtpOptionmandatory Binary coded options, select only one option at the same time:STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STOR… | OctetStringr/w Constraints: range: 4-4 | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.32 |
wtWebGraphAnalog57662AlarmTimerCronmandatory This entry defines a time window for alarm 1-8 and a activation time for the report.A time window is definied by start and stop time stamp, seperated by a space or tab. The activation time of the report is defined by a… | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.5.3.1.33 |
.1.3.6.1.4.1.5040.1.2.29.3.1.6.2.3
·
1 row entry
·
2 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebGraphAnalog57662SensorColor2Table
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-AnalogIO-57662-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-AnalogIO-57662-US-MIB::wtWebGraphAnalog57662SensorColor2Table'
List of sensor colors for the praphical presentation.
Numbers of the sensors.
Indexes
| Column | Syntax | OID |
|---|---|---|
| Color of the sensors at the praphical presention. | OctetStringr/w Constraints: range: 3-3 | .1.3.6.1.4.1.5040.1.2.29.3.1.6.2.3.1.1 |
| Assignes one of 4 scales to a sensor: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Use Scale 1 Bit 1 : Use Scale 2 Bit 2-7: unused | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.6.2.3.1.2 |
.1.3.6.1.4.1.5040.1.2.29.3.1.7.2
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebGraphAnalog57662ReportIfTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-AnalogIO-57662-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-AnalogIO-57662-US-MIB::wtWebGraphAnalog57662ReportIfTable'
List of Report indices.
Numbers of the Reports.
Indexes
| Column | Syntax | OID |
|---|---|---|
wtWebGraphAnalog57662ReportNomandatory Report number. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.5040.1.2.29.3.1.7.2.1.1 |
.1.3.6.1.4.1.5040.1.2.29.3.1.7.3
·
1 row entry
·
25 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebGraphAnalog57662ReportTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-AnalogIO-57662-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-AnalogIO-57662-US-MIB::wtWebGraphAnalog57662ReportTable'
List of settings depending on the Report number.
Report parameters of the individual Reports.
Indexes
| Column | Syntax | OID |
|---|---|---|
wtWebGraphAnalog57662ReportEnablemandatory Bin?r kodierte Triggerbedingungen:Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Report enable Bit 1-7: unused | OctetStringr/w Constraints: range: 4-4 | .1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.1 |
wtWebGraphAnalog57662ReportTimerCronmandatory This entry defines a time window for alarm 1-8 and a activation time for the report.A time window is definied by start and stop time stamp, seperated by a space or tab. The activation time of the report is defined by a… | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.2 |
| Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable Bit 3: Syslog enable Bit 4: FTP Client enable | OctetStringr/w Constraints: range: 4-4 | .1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.3 |
wtWebGraphAnalog57662ReportEMailAddrmandatory E-Mail address for sending the alarm mail to. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.8 |
| Subject line for alarm mail. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.9 |
wtWebGraphAnalog57662ReportMailTextmandatory Report mail text: <Mn> provides the current temperature; n = 1..2.<Z> provides the current time. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.10 |
wtWebGraphAnalog57662ReportManagerIPmandatory Name or IP address of the SNMP Manager which accepts the trap. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.11 |
wtWebGraphAnalog57662ReportTrapTextmandatory This text is sent in the trap body. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.12 |
| Binary coded options: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Thermo.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: unused | OctetStringr/w Constraints: range: 4-4 | .1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.13 |
wtWebGraphAnalog57662ReportTcpIpAddrmandatory Name or IP address of the TCP server which accepts the trap. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.14 |
wtWebGraphAnalog57662ReportTcpPortmandatory Port number of the TCP server which accepts the trap. | Integer32r/w Constraints: range: 1-65535 | .1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.15 |
wtWebGraphAnalog57662ReportTcpTextmandatory This text is sent in the TCP trap body. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.16 |
| Subject line for alarm clear mail. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.17 |
| Report clear mail text: <Mn> provides the current temperature; n = 1..2. <Z> provides the current time. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.18 |
| This text is sent in the trap body. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.19 |
| This text is sent in the TCP trap body. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.20 |
| IP address of the syslog server to which the Webio device should send syslog messages. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.24 |
| Port number of the syslog server to which the Webio device should send syslog messages. | Integer32r/w Constraints: range: 1-65535 | .1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.25 |
| Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.26 |
| Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body of a alarm clear message. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.27 |
| Local data port: 1..65535 or AUTO: the next free port will be assigned. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.28 |
| Name of the file including path informations. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.29 |
wtWebGraphAnalog57662ReportFtpTextmandatory Message text to store on the FTP server. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.30 |
| Report clear message to store on the FTP server. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.31 |
wtWebGraphAnalog57662ReportFtpOptionmandatory Binary coded options, select only one option at the same time:STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STOR… | OctetStringr/w Constraints: range: 4-4 | .1.3.6.1.4.1.5040.1.2.29.3.1.7.3.1.32 |
.1.3.6.1.4.1.5040.1.2.29.3.2.1
·
1 row entry
·
15 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebGraphAnalog57662PortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-AnalogIO-57662-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-AnalogIO-57662-US-MIB::wtWebGraphAnalog57662PortTable'
List of settings depending on the sensor number.
Sensor parameters for the individual sensors.
Indexes
| Column | Syntax | OID |
|---|---|---|
wtWebGraphAnalog57662PortNamemandatory Name of the sensor. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.2.1.1.1 |
wtWebGraphAnalog57662PortTextmandatory Description of the sensor. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.2.1.1.2 |
wtWebGraphAnalog57662PortOffset1mandatory Offset calibration: Offset in degrees with maximum 3 decimal places at set point 1. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.2.1.1.3 |
wtWebGraphAnalog57662SetPoint1mandatory Offset calibration: Reference set point 1 in degrees with maximum 3 decimal places. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.2.1.1.4 |
wtWebGraphAnalog57662PortOffset2mandatory Offset calibration: Offset in degrees with maximum 3 decimal places at set point 2. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.2.1.1.5 |
wtWebGraphAnalog57662SetPoint2mandatory Offset calibration: Reference set point 2 in degrees with maximum 3 decimal places. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.2.1.1.6 |
wtWebGraphAnalog57662PortCommentmandatory Offset calibration: informations of date, name of operator, reference devices. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.2.1.1.7 |
| Binary coded options for sensor 1: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : 0-20mA (default) Bit 1 : 4-20mA Bit 2 : Disconnect Bit 3-7: unused | OctetStringr/w Constraints: range: 4-4 | .1.3.6.1.4.1.5040.1.2.29.3.2.1.1.8 |
wtWebGraphAnalog57662PortUnitmandatory User scale: displayed unit. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.2.1.1.9 |
wtWebGraphAnalog57662PortScale0mandatory User scale: displayed value in 1/1000 at 0% full scale range.Range: -999999.999 to 999999.999 | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.2.1.1.10 |
wtWebGraphAnalog57662PortScale100mandatory User scale: displayed value in 1/1000 at 100% full scale range.Range: -999999.999 to 999999.999 | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.2.1.1.11 |
wtWebGraphAnalog57662PortOutputModemandatory This binary coded output mode defines the individual operation mode for anyoutput. More than one mode must not be selected. If an output mode is selected, Bit 2 in wtWebGraphAnalog57662PortInputMode will be set automat… | OctetStringr/w Constraints: range: 4-4 | .1.3.6.1.4.1.5040.1.2.29.3.2.1.1.12 |
wtWebGraphAnalog57662PortInputModemandatory This binary coded input mode defines the individual operation mode for anyinput. More than one mode must not be selected. If an input mode is selected, Bit 5 in wtWebGraphAnalog57662PortOutputMode will be set automatic… | OctetStringr/w Constraints: range: 4-4 | .1.3.6.1.4.1.5040.1.2.29.3.2.1.1.13 |
| This entry is used to optimize the step response with capcitive loads. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.29.3.2.1.1.14 |
| This binary coded compensation mode defines the individual operation mode for any output. If Auto adaptive is selected, the optimal value of wtWebGraphAnalog57662PortCompensationValue will be determinate continuously. S… | OctetStringr/w Constraints: range: 4-4 | .1.3.6.1.4.1.5040.1.2.29.3.2.1.1.15 |