WebGraph-Air-Quality-US-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
8
Rows
8
Columns
65
.1.3.6.1.4.1.5040.1.2.41.1.2
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebGraphAirQualitySensorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-Air-Quality-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-Air-Quality-US-MIB::wtWebGraphAirQualitySensorTable'
List of sensors.
List of sensor numbers.
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAirQualitySensorNomandatory
Sensor number.
|
Integer32 | .1.3.6.1.4.1.5040.1.2.41.1.2.1.1 |
.1.3.6.1.4.1.5040.1.2.41.1.3
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebGraphAirQualityTempValueTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-Air-Quality-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-Air-Quality-US-MIB::wtWebGraphAirQualityTempValueTable'
List of measurement values corresponding to the channel numbers.
Measurement values of the sensors.
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAirQualityTempValuemandatory
Measurement value of the sensor, ASCII, 5 characters in length.
|
OctetString | .1.3.6.1.4.1.5040.1.2.41.1.3.1.1 |
.1.3.6.1.4.1.5040.1.2.41.1.4
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebGraphAirQualityBinaryTempValueTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-Air-Quality-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-Air-Quality-US-MIB::wtWebGraphAirQualityBinaryTempValueTable'
List of binary measurement values corresponding to the channel numbers.
Binary measurement values of the sensors.
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAirQualityBinaryTempValuemandatory
Binary measurement value of the sensor in 1/10 degrees Celsius, 1/10 per cent
or 1/10 ppm, signed number, 0x7FFFFFFF indicates an invalid measured value. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.5040.1.2.41.1.4.1.1 |
.1.3.6.1.4.1.5040.1.2.41.1.8
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebGraphAirQualityTempValuePktTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-Air-Quality-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-Air-Quality-US-MIB::wtWebGraphAirQualityTempValuePktTable'
List of measurement values corresponding to the channel numbers.
Measurement values of the sensors.
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAirQualityTempValuePktmandatory
Measurement value of the sensor, ASCII, 5 characters in length, delimeter is decimal point.
|
OctetString | .1.3.6.1.4.1.5040.1.2.41.1.8.1.1 |
.1.3.6.1.4.1.5040.1.2.41.3.1.5.2
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebGraphAirQualityAlarmIfTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-Air-Quality-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-Air-Quality-US-MIB::wtWebGraphAirQualityAlarmIfTable'
List of alarm indices.
Numbers of the alarms.
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAirQualityAlarmNomandatory
Alarm number.
|
Integer32 | .1.3.6.1.4.1.5040.1.2.41.3.1.5.2.1.1 |
.1.3.6.1.4.1.5040.1.2.41.3.1.5.3
·
1 row entry
·
51 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebGraphAirQualityAlarmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-Air-Quality-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-Air-Quality-US-MIB::wtWebGraphAirQualityAlarmTable'
List of settings depending on the alarm number.
Alarm parameters of the individual alarms.
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAirQualityAlarmTriggermandatory
Binary coded trigger conditions:
Octet 1: unused Octet 2: unused Octet 3: Bit 0: Timer Bit 1: ColdStart Bit 2: WarmStart Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused |
OctetStringr/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.1 |
|
wtWebGraphAirQualityAlarmMinmandatory
Minimum temperature in degrees with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.2 |
|
wtWebGraphAirQualityAlarmMaxmandatory
Maximum temperature in degrees with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.3 |
|
wtWebGraphAirQualityAlarmHysteresismandatory
Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.)
, in degrees with maximum 2 decimal places. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.4 |
|
wtWebGraphAirQualityAlarmDelaymandatory
Alarm will be delayed by setting this time while stable alarm
condition occur (time in minutes). |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.5 |
|
wtWebGraphAirQualityAlarmIntervalmandatory
Send interval for alarm messages.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.6 |
|
wtWebGraphAirQualityAlarmEnablemandatory
Binary coded alarm enable:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.7 |
|
wtWebGraphAirQualityAlarmEMailAddrmandatory
E-Mail address for sending the alarm mail to.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.8 |
|
wtWebGraphAirQualityAlarmMailSubjectmandatory
Subject line for alarm mail.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.9 |
|
wtWebGraphAirQualityAlarmMailTextmandatory
Alarm mail text: <Tn> provides the current temperature; n = 1..8.
<Z> provides the current time. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.10 |
|
wtWebGraphAirQualityAlarmManagerIPmandatory
Name or IP address of the SNMP Manager which accepts the trap.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.11 |
|
wtWebGraphAirQualityAlarmTrapTextmandatory
This text is sent in the trap body.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.12 |
|
wtWebGraphAirQualityAlarmMailOptionsmandatory
Binary coded options:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Thermo.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: unused |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.13 |
|
wtWebGraphAirQualityAlarmTcpIpAddrmandatory
Name or IP address of the TCP server which accepts the trap.
|
OctetStringr/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.14 |
|
wtWebGraphAirQualityAlarmTcpPortmandatory
Port number of the TCP server which accepts the trap.
|
Integer32r/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.15 |
|
wtWebGraphAirQualityAlarmTcpTextmandatory
This text is sent in the TCP trap body.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.16 |
|
Subject line for alarm clear mail.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.17 |
|
Alarm clear mail text: <Tn> provides the current temperature; n = 1..8.
<Z> provides the current time. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.18 |
|
This text is sent in the trap body.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.19 |
|
This text is sent in the TCP trap body.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.20 |
|
wtWebGraphAirQualityAlarmDeltaTempmandatory
Maximum rate of change degrees/min with maximum 2 decimal places.
Compared with the average of a period of 5 minutes. |
OctetStringr/w Constraints: range: 4-4 |
.1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.21 |
|
wtWebGraphAirQualityAlarmRHMinmandatory
Minimum rel. Humidity in percent with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.22 |
|
wtWebGraphAirQualityAlarmRHMaxmandatory
Maximum rel.Humidity in percent with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.23 |
|
Hysteresis of rel. Humidity in percent with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.24 |
|
wtWebGraphAirQualityAlarmAHMinmandatory
Minimum abs. Humidity in g/(m*m*m) with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.25 |
|
wtWebGraphAirQualityAlarmAHMaxmandatory
Maximum abs. Humidity in g/(m*m*m) with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.26 |
|
IP address of the syslog server to which the Webio device should send syslog messages.
|
RFC1155-SMIIpAddressr/w Type Constraints: range: 4 |
.1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.27 |
|
wtWebGraphAirQualityAlarmSyslogPortmandatory
Port number of the syslog server to which the Webio device should send syslog messages.
|
Integer32r/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.28 |
|
wtWebGraphAirQualityAlarmSyslogTextmandatory
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.29 |
|
Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body. |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.30 |
|
wtWebGraphAirQualityAlarmFtpDataPortmandatory
Local data port: 1..65535 or AUTO: the next free port will be assigned.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.31 |
|
wtWebGraphAirQualityAlarmFtpFileNamemandatory
Name of the file including path informations.
|
OctetStringr/w Constraints: range: 1-65535 |
.1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.32 |
|
wtWebGraphAirQualityAlarmFtpTextmandatory
Message text to store on the FTP server.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.33 |
|
Alarm clear message to store on the FTP server.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.34 |
|
wtWebGraphAirQualityAlarmFtpOptionmandatory
Binary coded options, select only one option at the same time:
STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STOR… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.35 |
|
wtWebGraphAirQualityAlarmTimerCronmandatory
This entry contains 5 space or tab seperated text fields for time trigger definition.
Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Rang… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.36 |
|
wtWebGraphAirQualityAlarmVocMaxmandatory
Maximum VOC in ppm with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.37 |
|
Hysteresis of VOC in ppm with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.38 |
|
wtWebGraphAirQualityAlarmNamemandatory
Alert name
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.39 |
|
wtWebGraphAirQualityAlarmActivemandatory
Alert active
1 = ON 0 = OFF |
OctetStringr/w Constraints: range: 3-3 |
.1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.40 |
|
Binary coded options, select only one option at the same time:
OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : HHTP Request Authentication enable |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.61 |
|
HTTP Request: User
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.62 |
|
HTTP Request: Password
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.63 |
|
HTTP Request: Set URL
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.64 |
|
HTTP Request: Clear URL
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.65 |
|
HTTP Request: Server Port
|
Integer32r/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.66 |
|
MQTT Publish: Topic path
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.67 |
|
MQTT Publish: Topic SET message
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.68 |
|
MQTT Publish: Topic CLEAR message
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.69 |
|
Binary coded options:
OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 3-7: unused Bit 2 : Sensor 2 Bit 1 : Sensor 1 Bit 0 : Sensor 0 |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.70 |
|
wtWebGraphAirQualityAlarmLimitWindowmandatory
If window type is INSIDE the alarm is genereted when the temperature
is greater minumum value and lower than maximum value. If window type is OUTSIDE the alarm is generated when the measured value is lower than the mini… |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.5.3.1.71 |
.1.3.6.1.4.1.5040.1.2.41.3.1.6.2.3
·
1 row entry
·
2 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebGraphAirQualitySensorColorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-Air-Quality-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-Air-Quality-US-MIB::wtWebGraphAirQualitySensorColorTable'
List of sensor colors for the praphical presentation.
Numbers of the sensors.
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
Color of the sensors at the praphical presention.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.6.2.3.1.1 |
|
Assignes one of 4 scales to a sensor:
Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Use Scale 1 Bit 1 : Use Scale 2 Bit 2 : Use Scale 3 Bit 3-7: unused |
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.1.6.2.3.1.2 |
.1.3.6.1.4.1.5040.1.2.41.3.2.1
·
1 row entry
·
7 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebGraphAirQualityPortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-Air-Quality-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-Air-Quality-US-MIB::wtWebGraphAirQualityPortTable'
List of settings depending on the sensor number.
Sensor parameters for the individual sensors.
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
wtWebGraphAirQualityPortNamemandatory
Name of the sensor.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.2.1.1.1 |
|
wtWebGraphAirQualityPortTextmandatory
Description of the sensor.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.2.1.1.2 |
|
wtWebGraphAirQualityPortOffset1mandatory
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.2.1.1.3 |
|
wtWebGraphAirQualityPortTemperature1mandatory
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.2.1.1.4 |
|
wtWebGraphAirQualityPortOffset2mandatory
Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.2.1.1.5 |
|
wtWebGraphAirQualityPortTemperature2mandatory
Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.2.1.1.6 |
|
wtWebGraphAirQualityPortCommentmandatory
Offset calibration: informations of date, name of operator, reference devices.
|
OctetStringr/w | .1.3.6.1.4.1.5040.1.2.41.3.2.1.1.7 |