WebGraph-2xThermometer-US-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
9
Rows
9
Columns
62
.1.3.6.1.4.1.5040.1.2.43.1.2
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebioAn2GraphSensorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-2xThermometer-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-2xThermometer-US-MIB::wtWebioAn2GraphSensorTable'
List of sensors.
Temperature sensor numbers.
Indexes
| Column | Syntax | OID |
|---|---|---|
wtWebioAn2GraphSensorNomandatory Temperature sensor number. | Integer32 Constraints: range: 1-2 | .1.3.6.1.4.1.5040.1.2.43.1.2.1.1 |
.1.3.6.1.4.1.5040.1.2.43.1.3
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebioAn2GraphTempValueTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-2xThermometer-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-2xThermometer-US-MIB::wtWebioAn2GraphTempValueTable'
List of temperature values corresponding to the channel numbers.
Temperatures of the sensors.
Indexes
| Column | Syntax | OID |
|---|---|---|
wtWebioAn2GraphTempValuemandatory Temperature value of the sensor, ASCII, 5 characters in length. | OctetString Constraints: range: 5-5 | .1.3.6.1.4.1.5040.1.2.43.1.3.1.1 |
.1.3.6.1.4.1.5040.1.2.43.1.4
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebioAn2GraphBinaryTempValueTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-2xThermometer-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-2xThermometer-US-MIB::wtWebioAn2GraphBinaryTempValueTable'
List of binary temperature values corresponding to the channel numbers.
Binary temperature values of the sensors.
Indexes
| Column | Syntax | OID |
|---|---|---|
wtWebioAn2GraphBinaryTempValuemandatory Binary temperature value of the sensor in 1/10 degrees Celsius,signed number, 0x4FFF6 indicates an invalid measured value. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.5040.1.2.43.1.4.1.1 |
.1.3.6.1.4.1.5040.1.2.43.1.8
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebioAn2GraphTempValuePktTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-2xThermometer-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-2xThermometer-US-MIB::wtWebioAn2GraphTempValuePktTable'
List of temperature values corresponding to the channel numbers.
Temperatures of the sensors.
Indexes
| Column | Syntax | OID |
|---|---|---|
wtWebioAn2GraphTempValuePktmandatory Temperature value of the sensor, ASCII, 5 characters in length, decimal point. | OctetString Constraints: range: 5-5 | .1.3.6.1.4.1.5040.1.2.43.1.8.1.1 |
.1.3.6.1.4.1.5040.1.2.43.3.1.4.4
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebioAn2GraphSensorColorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-2xThermometer-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-2xThermometer-US-MIB::wtWebioAn2GraphSensorColorTable'
List of sensor colors for the praphical presentation.
Index numbers of the sensors.
Indexes
| Column | Syntax | OID |
|---|---|---|
wtWebioAn2GraphSensorColormandatory Color of the sensors at the praphical presention. | OctetStringr/w Constraints: range: 3-3 | .1.3.6.1.4.1.5040.1.2.43.3.1.4.4.1.1 |
.1.3.6.1.4.1.5040.1.2.43.3.1.5.2
·
1 row entry
·
1 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebioAn2GraphAlarmIfTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-2xThermometer-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-2xThermometer-US-MIB::wtWebioAn2GraphAlarmIfTable'
List of alarm indices.
Numbers of the alarms.
Indexes
| Column | Syntax | OID |
|---|---|---|
wtWebioAn2GraphAlarmNomandatory Alarm number. | Integer32 Constraints: range: 1-2 | .1.3.6.1.4.1.5040.1.2.43.3.1.5.2.1.1 |
.1.3.6.1.4.1.5040.1.2.43.3.1.5.3
·
1 row entry
·
46 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebioAn2GraphAlarmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-2xThermometer-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-2xThermometer-US-MIB::wtWebioAn2GraphAlarmTable'
List of settings depending on the alarm number.
Alarm parameters of the individual alarms.
Indexes
| Column | Syntax | OID |
|---|---|---|
wtWebioAn2GraphAlarmTriggermandatory Binary coded trigger conditions:Octet 1: unused Octet 2: unused Octet 3: Bit 0: Timer Bit 1: ColdStart Bit 2: WarmStart Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 B… | OctetStringr/w Constraints: range: 4-4 | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.1 |
wtWebioAn2GraphAlarmMinmandatory Minimum temperature in degrees with maximum 2 decimal places. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.2 |
wtWebioAn2GraphAlarmMaxmandatory Maximum temperature in degrees with maximum 2 decimal places. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.3 |
wtWebioAn2GraphAlarmHysteresismandatory Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.), in degrees with maximum 2 decimal places. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.4 |
wtWebioAn2GraphAlarmDelaymandatory Alarm will be delayed by setting this time while stable alarm condition occur (time in minutes). | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.5 |
wtWebioAn2GraphAlarmIntervalmandatory Send interval for alarm messages. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.6 |
wtWebioAn2GraphAlarmEnablemandatory Binary coded alarm enable:Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable | OctetStringr/w Constraints: range: 4-4 | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.7 |
wtWebioAn2GraphAlarmEMailAddrmandatory E-Mail address for sending the alarm mail to. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.8 |
wtWebioAn2GraphAlarmMailSubjectmandatory Subject line for alarm mail. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.9 |
wtWebioAn2GraphAlarmMailTextmandatory Alarm mail text: <Tn> provides the current temperature; n = 1..2.<Z> provides the current time. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.10 |
wtWebioAn2GraphAlarmManagerIPmandatory Name or IP address of the SNMP Manager which accepts the trap. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.11 |
wtWebioAn2GraphAlarmTrapTextmandatory This text is sent in the trap body. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.12 |
wtWebioAn2GraphAlarmMailOptionsmandatory Binary coded options:Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Thermo.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: unused | OctetStringr/w Constraints: range: 4-4 | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.13 |
wtWebioAn2GraphAlarmTcpIpAddrmandatory Name or IP address of the TCP server which accepts the trap. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.14 |
wtWebioAn2GraphAlarmTcpPortmandatory Port number of the TCP server which accepts the trap. | Integer32r/w Constraints: range: 1-65535 | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.15 |
wtWebioAn2GraphAlarmTcpTextmandatory This text is sent in the TCP trap body. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.16 |
wtWebioAn2GraphAlarmClearMailSubjectmandatory Subject line for alarm clear mail. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.17 |
wtWebioAn2GraphAlarmClearMailTextmandatory Alarm clear mail text: <Tn> provides the current temperature; n = 1..2.<Z> provides the current time. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.18 |
wtWebioAn2GraphAlarmClearTrapTextmandatory This text is sent in the trap body. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.19 |
wtWebioAn2GraphAlarmClearTcpTextmandatory This text is sent in the TCP trap body. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.20 |
wtWebioAn2GraphAlarmSyslogIpAddrmandatory IP address of the syslog server to which the Webio device should send syslog messages. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.21 |
wtWebioAn2GraphAlarmSyslogPortmandatory Port number of the syslog server to which the Webio device should send syslog messages. | Integer32r/w Constraints: range: 1-65535 | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.22 |
wtWebioAn2GraphAlarmSyslogTextmandatory Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.This text appears in the following syslog message body. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.23 |
wtWebioAn2GraphAlarmSyslogClearTextmandatory Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.This text appears in the following syslog message body. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.24 |
wtWebioAn2GraphAlarmFtpDataPortmandatory Local data port: 1..65535 or AUTO: the next free port will be assigned. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.25 |
wtWebioAn2GraphAlarmFtpFileNamemandatory Name of the file including path informations. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.26 |
wtWebioAn2GraphAlarmFtpTextmandatory Message text to store on the FTP server. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.27 |
wtWebioAn2GraphAlarmFtpClearTextmandatory Alarm clear message to store on the FTP server. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.28 |
wtWebioAn2GraphAlarmFtpOptionmandatory Binary coded options, select only one option at the same time:STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STOR… | OctetStringr/w Constraints: range: 4-4 | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.29 |
wtWebioAn2GraphAlarmTimerCronmandatory This entry contains 5 text fields space or tab seperated for time trigger definition.Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Rang… | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.30 |
wtWebioAn2GraphAlarmNamemandatory Alert name | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.39 |
wtWebioAn2GraphAlarmActivemandatory Alert active1 = ON 0 = OFF | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.40 |
| Binary coded options, select only one option at the same time: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : HHTP Request Authentication enable | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.61 |
wtWebioAn2GraphAlarmHttpReqAuthUsermandatory HTTP Request: User | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.62 |
| HTTP Request: Password | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.63 |
wtWebioAn2GraphAlarmHttpReqSetUrlmandatory HTTP Request: Set URL | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.64 |
wtWebioAn2GraphAlarmHttpReqClearUrlmandatory HTTP Request: Clear URL | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.65 |
| HTTP Request: Server Port | Integer32r/w Constraints: range: 1-65535 | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.66 |
wtWebioAn2GraphAlarmMqttTopicPathmandatory MQTT Publish: Topic path | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.67 |
| MQTT Publish: Topic SET message | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.68 |
wtWebioAn2GraphAlarmMqttTopicClearmandatory MQTT Publish: Topic CLEAR message | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.69 |
| Binary coded options: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 2-7: unused Bit 1 : Sensor 1 Bit 0 : Sensor 0 | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.70 |
wtWebioAn2GraphAlarmLimitWindowmandatory If window type is INSIDE the alarm is genereted when the temperatureis greater minumum value and lower than maximum value. If window type is OUTSIDE the alarm is generated when the measured value is lower than the mini… | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.71 |
wtWebioAn2GraphAlarmSnmpManagerPortmandatory Port number of the SNMP Manager to which the Webio device should send SNMP traps. | Integer32r/w Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.76 |
wtWebioAn2GraphAlarmMqttQoSmandatory Binary coded value:Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: QoS 0 Bit 1: QoS 1 Bit 2: QoS 2 Bit 3-7:unused | OctetStringr/w Constraints: range: 4-4 | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.77 |
wtWebioAn2GraphAlarmMqttRetainmandatory Binary coded value:Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : retain enable Bit 1-7 : unused | OctetStringr/w Constraints: range: 4-4 | .1.3.6.1.4.1.5040.1.2.43.3.1.5.3.1.78 |
.1.3.6.1.4.1.5040.1.2.43.3.1.6.2.3
·
1 row entry
·
2 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebioAn2GraphSelectSensorColorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-2xThermometer-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-2xThermometer-US-MIB::wtWebioAn2GraphSelectSensorColorTable'
List of sensor colors for the praphical presentation.
Numbers of the sensors.
Indexes
| Column | Syntax | OID |
|---|---|---|
| Color of the sensors at the praphical presention. | OctetStringr/w Constraints: range: 3-3 | .1.3.6.1.4.1.5040.1.2.43.3.1.6.2.3.1.1 |
| Assignes one of 4 scales to a sensor: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Use Scale 1 Bit 1 : Use Scale 2 Bit 2 : Use Scale 3 Bit 3 : Use Scale 4 … | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.1.6.2.3.1.2 |
.1.3.6.1.4.1.5040.1.2.43.3.2.1
·
1 row entry
·
8 columns
Uses the webgraph variant from
Command help
/opt/observium/mibs/webgraph.
Walk wtWebioAn2GraphPortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WebGraph-2xThermometer-US-MIB' -M '/opt/observium/mibs/webgraph:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WebGraph-2xThermometer-US-MIB::wtWebioAn2GraphPortTable'
List of settings depending on the sensor number.
Sensor parameters for the individual sensors.
Indexes
| Column | Syntax | OID |
|---|---|---|
wtWebioAn2GraphPortNamemandatory Name of the sensor. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.2.1.1.1 |
wtWebioAn2GraphPortTextmandatory Description of the sensor. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.2.1.1.2 |
wtWebioAn2GraphPortOffset1mandatory Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.2.1.1.3 |
wtWebioAn2GraphPortTemperature1mandatory Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.2.1.1.4 |
wtWebioAn2GraphPortOffset2mandatory Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.2.1.1.5 |
wtWebioAn2GraphPortTemperature2mandatory Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.2.1.1.6 |
wtWebioAn2GraphPortCommentmandatory Offset calibration: informations of date, name of operator, reference devices. | OctetStringr/w | .1.3.6.1.4.1.5040.1.2.43.3.2.1.1.7 |
wtWebioAn2GraphPortSensorSelectmandatory Bin?r kodierte Optionen f?r Sensor:Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0 : PT100 Bit 1 : PT1000 (default) Bit 2-7: ungenutzt | OctetStringr/w Constraints: range: 4-4 | .1.3.6.1.4.1.5040.1.2.43.3.2.1.1.8 |