WWP-LEOS-PORT-XCVR-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
1
Rows
1
Columns
86
.1.3.6.1.4.1.6141.2.60.4.1.1.1 · 1 row entry · 86 columns
Uses the ciena variant from /opt/observium/mibs/ciena.
Command help
Walk wwpLeosPortXcvrTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'WWP-LEOS-PORT-XCVR-MIB' -M '/opt/observium/mibs/ciena:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'WWP-LEOS-PORT-XCVR-MIB::wwpLeosPortXcvrTable'
This table contains descriptions and settings for each of the 
physical transceiver devices.
wwpLeosPortXcvrEntry row .1.3.6.1.4.1.6141.2.60.4.1.1.1.1
The Transciever Device Entry.
Column Syntax OID
The ID for the transceiver.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.1
The operational state of the transceiver.
Enumeration
Enumerated Values:
1disabled
2enabled
3loopback
4notPresent
5faulted
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.2
Type for the transceiver.
Enumeration
Enumerated Values:
1unknown
2gbic
3solderedType
4sfp
5reserved
6vendorSpecific
7xbi
8xenpak
9xfp
10xff
11xfpe
12xpak
13x2
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.3
Extended identifier type for this transceiver.
Enumeration
Enumerated Values:
1unknown
2sfp-gbic
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.4
Type of connector.
unknown(1),
sc(2),
fiberChannelStyle1(3),
fiberChannelStyle2(4),
bnc/tnc(5),
coaxialHeader(6),
fiberJack(7),
lc(8),
mt-rj(9),
mu(10),
sg(11),
opticalPitTail…
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.5
Type of Transceiver.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.6
String containing this transceiver's vendor name.
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.7
String containing this transceiver's vendor OUI.
OctetString
Constraints:
range: 0-255
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.8
String containing this transceiver's vendor OUI.
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.9
String containing this transceiver's part revision number.
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.10
String containing this transceiver's part serial number.
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.11
If wwpLeosPortXcvrIdentiferType is SFP, then the following values is defined for the encoding type:
unspecified(1),
8B10B(2),
4b5b(3),
NRZ(4),
Manchester(5),
SONET(6),
reserved(7-256)
If wwpLeosPortXcvrIdentiferType is …
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.12
The transceiver's manufacture date in string.
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.13
This represents the compliance version.
Value 1 means digital diagnostic functionality
not included or undefined
Value 2 means includes functionality defined in
Rev 9.0 SFF-8472
Value 3 means TBD
Value 4 means TBD.
Integer32
Constraints:
range: 1-4
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.14
This represents the wavelength of the transceiver. Units are nano meter.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.15
This represents the temperature of the transceiver. Units are in degrees C
centigradeInteger32
Constraints:
range: 1-65535
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.16
This represents the voltage of the transceiver.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.17
This represents the bias of the transceiver.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.18
This represents the measured receive power of the transceiver.
Units are micro Watts.
uWInteger32
Constraints:
range: 1-65535
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.19
Indicates whether this transceiver is currently set to transmit.
Enumeration
Enumerated Values:
1enabled
2disabled
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.20
Indicates the fault status of this transceiver.
Enumeration
Enumerated Values:
1fault
2noFault
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.21
Indicates the Rx rate status of this transceiver.
Enumeration
Enumerated Values:
1enabled
2disabled
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.22
Indicates the link length for 9/125um fiber.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.23
Indicates the link length for 50/125um fiber.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.24
Indicates the link length for 62.5/125um fiber.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.25
Indicates the link length for copper.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.26
Indicates the Tx Output power for the transceiver.
Units are micro Watts.
uWInteger32
Constraints:
range: 1-65535
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.27
Indicates the Loss Of Signal State for the optical transceiver.
Ports without optical transceiver will always report 'false'.
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.28
Indicates if diagnostics are supported on this transceiver.
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.29
Indicates if enhanced diagnostics alarms / warnings implemented.
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.30
Indicates if enhanced diagnostics soft Tx disable control is implemented.
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.31
Indicates if enhanced diagnostics soft Tx fault monitoring is implemented.
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.32
Indicates if enhanced diagnostics Rx LOS monitoring is implemented.
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.33
Indicates the higher threshold for temperature alarm.
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.34
Indicates the lower threshold for temperature alarm.
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.35
Indicates the higher threshold for voltage alarm.
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.36
Indicates the lower threshold for voltage alarm.
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.37
Indicates the higher threshold for bias alarm.
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.38
Indicates the lower threshold for bias alarm.
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.39
Indicates the higher threshold for Tx power alarm.
Units are micro watts
uWSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.40
Indicates the lower threshold for Tx power alarm.
Units are micro watts.
uWSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.41
Indicates the higher threshold for Rx power alarm.
Units are micro watts.
uWSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.42
Indicates the lower threshold for Rx power alarm.
Units are micro watts.
uWSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.43
Indicates if enhanced diagnostics soft rate select control is implemented.
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.44
The admin state of the transceiver.
Enumerationr/w
Enumerated Values:
1disabled
2enabled
3loopback
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.45
This represents the minimum bit rate.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.70
This represents the maximum bit rate.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.71
This represents the length (SMF fiber) 1km.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.72
This represents the length (ext. BW MMF) 2m.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.73
This represents the length (50um) 1m.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.74
This represents the length (62.5um) 1m.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.75
This represents the length (copper) 1m.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.76
This represents the device technology.
Enumeration
Enumerated Values:
1vcsel850nm
2vcsel1310nm
3vcsel1550nm
4fp1310nm
5dfb1310nm
6dfb1550nm
7eml1310nm
8eml1550nm
9copperOrOther
10tunable1550nm
11reserved
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.77
This represents the device transmitter technology:
Bit 3: Wavelength Control (active/none)
Bit 2: Transmitter Cooling (cooled/uncooled)
Bit 1: Detector Type (apd/pin)
Bit 0: Transmitter Tuning (Tunable/non-Tunable)
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.78
This represents the CDR support:
Bit 7: 9.95 Gb/s (yes/no)
Bit 6: 10.3 Gb/s (yes/no)
Bit 5: 10.5 Gb/s (yes/no)
Bit 4: 10.7 Gb/s (yes/no)
Bit 3: 11.1 Gb/s (yes/no)
Bit 2: N/A
Bit 1: Lineside Loopback (yes/no)
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.79
This represents the wavelength tolerance.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.80
This represents the maximum case temperature.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.81
This represents the maximum power dissipation.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.82
This represents the 5.0 Volt Max Current.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.83
This represents the 3.3 Volt Max Current.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.84
This represents the 1.8 Volt Max Current.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.85
This represents the -5.2 Volt Max Current.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.86
This represents the diag monitor type:
Bit 4 indicates BER support.
Bit 3 indidates the Rx Power Meas. type of Avg or OMA.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.87
This represents the enhanced options:
Bit 7: VPS Support (yes/no)
Bit 6: Soft TX_DISABLE (yes/no)
Bit 5: Soft P_down (yes/no)
Bit 4: VPS LV Regulator Mode (yes/no)
Bit 3: VPS bypassed Reg. Mode (yes/no)
Bit 2: Active FE…
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.88
This represents the Aux monitoring of A/D input 1.
Enumeration
Enumerated Values:
1none
2aPDBiasVoltage
3reserved
4tECCurrentMa
5laserTemp
6laserWavelength
7voltage5V
8voltage3p3V
9voltage1p8V
10voltageNeg5p2V
11voltage5VCurrent
12voltage3p3VCurrent
13voltage1p8VCurrent
14voltageNeg5p2VCurrent
15unknown
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.89
This represents the Aux monitoring of A/D input 2.
Enumeration
Enumerated Values:
1none
2aPDBiasVoltage
3reserved
4tECCurrentMa
5laserTemp
6laserWavelength
7voltage5V
8voltage3p3V
9voltage1p8V
10voltageNeg5p2V
11voltage5VCurrent
12voltage3p3VCurrent
13voltage1p8VCurrent
14voltageNeg5p2VCurrent
15unknown
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.90
The admin frequency of the transceiver in GHz
Unsigned32r/w
Constraints:
range: 0-4294967295
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.91
This represents the first frequency in GHz
Unsigned32
Constraints:
range: 0-4294967295
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.92
This represents the last frequency in GHz
Unsigned32
Constraints:
range: 0-4294967295
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.93
This represents the maximun support grid spacing in GHz
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.94
This represents the channel number
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.95
This represents the frequency error
Integer32
Constraints:
range: -32768-32767
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.96
The admin wavelength of the transceiver in pico-meter
SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.97
The admin channel number of the transceiver
SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.98
This represents the first wavelength in pico meter
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.99
This represents the last wavelength in pico meter
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.100
This represents the first channel number
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.101
This represents the last channel number
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.102
The operational frequency of the transceiver in GHz
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.103
The operational wavelength of the transceiver in pico-meter
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.104
Indicates the Rx power level in dBm after scaling and conversion to an integer.
To convert back to dBm, convert this value to floating point and divide by 10,000.
dBmSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.105
Indicates the Tx power level in dBm after scaling and conversion to an integer.
To convert back to dBm, convert this value to floating point and divide by 10,000.
dBmSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.106
Indicates the higher threshold for Tx power alarm in dBm after scaling and conversion to an integer.
To convert back to dBm, convert this value to floating point and divide by 10,000.
dBmSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.107
Indicates the lower threshold for Tx power alarm in dBm after scaling and conversion to an integer.
To convert back to dBm, convert this value to floating point and divide by 10,000.
dBmSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.108
Indicates the higher threshold for Rx power alarm in dBm after scaling and conversion to an integer.
To convert back to dBm, convert this value to floating point and divide by 10,000.
dBmSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.109
Indicates the lower threshold for Rx power alarm in dBm after scaling and conversion to an integer.
To convert back to dBm, convert this value to floating point and divide by 10,000.
dBmSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.6141.2.60.4.1.1.1.1.110