USHA-P-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
10
Rows
10
Columns
53
.1.3.6.1.4.1.2468.1.2.1.1.3.3
·
1 row entry
·
7 columns
Uses the ingrasys variant from
Command help
/opt/observium/mibs/ingrasys.
Walk upsInputGroupTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'USHA-P-MIB' -M '/opt/observium/mibs/ingrasys:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'USHA-P-MIB::upsInputGroupTable'
A list of input table entries. The number of entries is given by the value of upsInputGroupNumLines.
An entry containing information applicable to a
particular input line.
particular input line.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
upsInputGroupLineIndexmandatory
The index of UpsInputGroupEntry.
|
UPS-MIBPositiveInteger Constraints: range: 0-65535 |
.1.3.6.1.4.1.2468.1.2.1.1.3.3.1.1 |
|
upsInputGroupFrequencymandatory
The present input frequency.
|
UPS-MIBNonNegativeInteger Type Constraints: range: 0..2147483647 |
.1.3.6.1.4.1.2468.1.2.1.1.3.3.1.2 |
|
upsInputGroupVoltagemandatory
The input utility line voltage in 0.1 volts.
|
UPS-MIBNonNegativeInteger Type Constraints: range: 0..2147483647 |
.1.3.6.1.4.1.2468.1.2.1.1.3.3.1.3 |
|
upsInputGroupCurrentmandatory
The magnitude of the present input current in 0.1 A.
|
UPS-MIBNonNegativeInteger Type Constraints: range: 0..2147483647 |
.1.3.6.1.4.1.2468.1.2.1.1.3.3.1.4 |
|
upsInputGroupTruePowermandatory
The magnitude of the present input true power.
|
UPS-MIBNonNegativeInteger Type Constraints: range: 0..2147483647 |
.1.3.6.1.4.1.2468.1.2.1.1.3.3.1.5 |
|
upsInputGroupVoltageMaxmandatory
The maximum utility line voltage in 0.1 VAC for last 1 minute.
|
UPS-MIBNonNegativeInteger Type Constraints: range: 0..2147483647 |
.1.3.6.1.4.1.2468.1.2.1.1.3.3.1.6 |
|
upsInputGroupVoltageMinmandatory
The minimum utility line voltage in 0.1 VAC for last 1 minute.
|
UPS-MIBNonNegativeInteger Type Constraints: range: 0..2147483647 |
.1.3.6.1.4.1.2468.1.2.1.1.3.3.1.7 |
.1.3.6.1.4.1.2468.1.2.1.1.4.4
·
1 row entry
·
5 columns
Uses the ingrasys variant from
Command help
/opt/observium/mibs/ingrasys.
Walk upsOutputGroupTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'USHA-P-MIB' -M '/opt/observium/mibs/ingrasys:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'USHA-P-MIB::upsOutputGroupTable'
A list of output table entries. The number of entries is given by the value of upsOutputGroupNumLines.
An entry containing information applicable to a
particular output line.
particular output line.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
upsOutputGroupLineIndexmandatory
The output line identifier.
|
UPS-MIBPositiveInteger Constraints: range: 0-65535 |
.1.3.6.1.4.1.2468.1.2.1.1.4.4.1.1 |
|
upsOutputGroupVoltagemandatory
The output voltage of the UPS system in 0.1 volts.
|
UPS-MIBNonNegativeInteger Type Constraints: range: 0..2147483647 |
.1.3.6.1.4.1.2468.1.2.1.1.4.4.1.2 |
|
upsOutputGroupCurrentmandatory
The output current of the UPS system in 0.1 Amps.
|
UPS-MIBNonNegativeInteger Type Constraints: range: 0..2147483647 |
.1.3.6.1.4.1.2468.1.2.1.1.4.4.1.3 |
|
upsOutputGroupPowermandatory
The present output true power.
|
UPS-MIBNonNegativeInteger Type Constraints: range: 0..2147483647 |
.1.3.6.1.4.1.2468.1.2.1.1.4.4.1.4 |
|
upsOutputGroupPercentLoadmandatory
The percentage of the UPS power capacity presently
being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2468.1.2.1.1.4.4.1.5 |
.1.3.6.1.4.1.2468.1.2.1.1.5.3
·
1 row entry
·
4 columns
Uses the ingrasys variant from
Command help
/opt/observium/mibs/ingrasys.
Walk upsBypassGroupTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'USHA-P-MIB' -M '/opt/observium/mibs/ingrasys:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'USHA-P-MIB::upsBypassGroupTable'
A list of bypass table entries. The number of entries is given by the value of upsBypassGroupNumLines.
An entry containing information applicable to a
particular bypass input.
particular bypass input.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
upsBypassGroupLineIndexmandatory
The bypass line identifier.
|
UPS-MIBPositiveInteger Constraints: range: 0-65535 |
.1.3.6.1.4.1.2468.1.2.1.1.5.3.1.1 |
|
upsBypassGroupVoltagemandatory
The present bypass voltage.
|
UPS-MIBNonNegativeInteger Type Constraints: range: 0..2147483647 |
.1.3.6.1.4.1.2468.1.2.1.1.5.3.1.2 |
|
upsBypassGroupCurrentmandatory
The present bypass current.
|
UPS-MIBNonNegativeInteger Type Constraints: range: 0..2147483647 |
.1.3.6.1.4.1.2468.1.2.1.1.5.3.1.3 |
|
upsBypassGroupPowermandatory
The present true power conveyed by the bypass.
|
UPS-MIBNonNegativeInteger Type Constraints: range: 0..2147483647 |
.1.3.6.1.4.1.2468.1.2.1.1.5.3.1.4 |
.1.3.6.1.4.1.2468.1.2.1.1.6.6
·
1 row entry
·
6 columns
Uses the ingrasys variant from
Command help
/opt/observium/mibs/ingrasys.
Walk upsBatteryTestScheduleTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'USHA-P-MIB' -M '/opt/observium/mibs/ingrasys:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'USHA-P-MIB::upsBatteryTestScheduleTable'
Table which describes the schedule for automatically battery test.
Indexes
| Column | Syntax | OID | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
upsBatteryTestScheduleIndexmandatory
The index of battery test scheduled.
|
Integer32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.2468.1.2.1.1.6.6.1.1 |
||||||||||||||||||
|
upsBatteryTestScheduleDaymandatory
The weekday on which the UPS should start battery test.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.2468.1.2.1.1.6.6.1.2 |
||||||||||||||||||
|
upsBatteryTestScheduleTimemandatory
The time that the battery test will be initiated in hh:mm format.
|
RFC1213-MIBDisplayStringr/w Constraints: range: 5-5 |
.1.3.6.1.4.1.2468.1.2.1.1.6.6.1.3 |
||||||||||||||||||
|
upsBatteryTestScheduleTypemandatory
The type of battery test.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.2468.1.2.1.1.6.6.1.4 |
||||||||||||||||||
|
upsBatteryTestScheduleTestWithTimemandatory
The battTestWithTime of battery test is supported or not.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2468.1.2.1.1.6.6.1.5 |
||||||||||||||||||
|
upsBatteryTestScheduleSpecialDaymandatory
The special day that the battery test will be initiated in dd/mm/yyyy format.
|
RFC1213-MIBDisplayStringr/w Constraints: range: 10-10 |
.1.3.6.1.4.1.2468.1.2.1.1.6.6.1.6 |
.1.3.6.1.4.1.2468.1.2.1.1.7.4
·
1 row entry
·
5 columns
Uses the ingrasys variant from
Command help
/opt/observium/mibs/ingrasys.
Walk upsControlShutdownParametersTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'USHA-P-MIB' -M '/opt/observium/mibs/ingrasys:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'USHA-P-MIB::upsControlShutdownParametersTable'
Table which describes the parametes for shutdown process when shutdown event occurs
Indexes
| Column | Syntax | OID | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
upsControlEventmandatory
The shutdown event identification
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2468.1.2.1.1.7.4.1.1 |
||||||||||||||||||
|
upsControlEventStatusmandatory
Status of the corresponding shutdown Event.
When set to disable(), shutdown process will not start when corresponding event occured. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.2468.1.2.1.1.7.4.1.2 |
||||||||||||||||||
|
upsControlDelaymandatory
The Delay after the occurance of the curresponding shutdown
event that USHA should issue shutdown request to connected clients. For WeeklyScheduledShutdown and SpecialScheduledShutdown, this is the time before the confi… |
Integer32r/w Constraints: range: 0-10080 |
.1.3.6.1.4.1.2468.1.2.1.1.7.4.1.3 |
||||||||||||||||||
|
upsControlFirstWarningmandatory
The delay after the occurance of the curresponding shutdown
event that the USHA will start sending the warning message to the connected clients. The value is in units of seconds |
Integer32r/w Constraints: range: 0-3600 |
.1.3.6.1.4.1.2468.1.2.1.1.7.4.1.4 |
||||||||||||||||||
|
upsControlWarningIntervalmandatory
The frequency of sending warning messages to the connected
clients when the curresponding shutdown event occurs. The value is in units of seconds. |
Integer32r/w Constraints: range: 0-3600 |
.1.3.6.1.4.1.2468.1.2.1.1.7.4.1.5 |
.1.3.6.1.4.1.2468.1.2.1.1.7.5
·
1 row entry
·
5 columns
Uses the ingrasys variant from
Command help
/opt/observium/mibs/ingrasys.
Walk upsControlWeeklyScheduleTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'USHA-P-MIB' -M '/opt/observium/mibs/ingrasys:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'USHA-P-MIB::upsControlWeeklyScheduleTable'
The table to schedule shutting down the ups by weekly.
The entries for each day.
Indexes
| Column | Syntax | OID | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
upsControlWeeklyIndexmandatory
The index of scheduled events.
|
Integer32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.2468.1.2.1.1.7.5.1.1 |
||||||||||||||||
|
upsControlWeeklyShutdownDaymandatory
The weekday on which the UPS should shut down.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.2468.1.2.1.1.7.5.1.2 |
||||||||||||||||
|
upsControlWeeklyShutdownTimemandatory
The time that the process of shutting down the UPS will be initiated
in hh:mm format. |
RFC1213-MIBDisplayStringr/w Constraints: range: 5-5 |
.1.3.6.1.4.1.2468.1.2.1.1.7.5.1.3 |
||||||||||||||||
|
upsControlWeeklyRestartDaymandatory
The weekday on which the UPS should restart
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.2468.1.2.1.1.7.5.1.4 |
||||||||||||||||
|
upsControlWeeklyRestartTimemandatory
The time the UPS will restart in hh:mm format.
|
RFC1213-MIBDisplayStringr/w Constraints: range: 5-5 |
.1.3.6.1.4.1.2468.1.2.1.1.7.5.1.5 |
.1.3.6.1.4.1.2468.1.2.1.1.7.6
·
1 row entry
·
5 columns
Uses the ingrasys variant from
Command help
/opt/observium/mibs/ingrasys.
Walk upsControlSpecialScheduleTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'USHA-P-MIB' -M '/opt/observium/mibs/ingrasys:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'USHA-P-MIB::upsControlSpecialScheduleTable'
The table to schedule shutting down the ups.
The entries for each day.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
upsControlSpecialIndexmandatory
The index of scheduled events.
|
Integer32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.2468.1.2.1.1.7.6.1.1 |
|
upsControlSpecialShutdownDaymandatory
The date on which the UPS should shut down in dd/mm/yyyy
format. |
RFC1213-MIBDisplayStringr/w Constraints: range: 10-10 |
.1.3.6.1.4.1.2468.1.2.1.1.7.6.1.2 |
|
upsControlSpecialShutdownTimemandatory
The time that the process of shutting down the UPS will be initiated
in hh:mm format |
RFC1213-MIBDisplayStringr/w Constraints: range: 5-5 |
.1.3.6.1.4.1.2468.1.2.1.1.7.6.1.3 |
|
upsControlSpecialRestartDaymandatory
The date on which the UPS should restart in dd/mm/yyyy format
|
RFC1213-MIBDisplayStringr/w Constraints: range: 10-10 |
.1.3.6.1.4.1.2468.1.2.1.1.7.6.1.4 |
|
upsControlSpecialRestartTimemandatory
The time the UPS will restart in hh:mm format.
|
RFC1213-MIBDisplayStringr/w Constraints: range: 5-5 |
.1.3.6.1.4.1.2468.1.2.1.1.7.6.1.5 |
.1.3.6.1.4.1.2468.1.2.1.1.9.2
·
1 row entry
·
6 columns
Uses the ingrasys variant from
Command help
/opt/observium/mibs/ingrasys.
Walk upsDevicesTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'USHA-P-MIB' -M '/opt/observium/mibs/ingrasys:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'USHA-P-MIB::upsDevicesTable'
The devices powered by UPS and registered to USHA
The devices protected by USHA
Indexes
| Column | Syntax | OID |
|---|---|---|
|
indexOfDevicemandatory
The index of the device that is plugged into the UPS.
|
UPS-MIBNonNegativeInteger Type Constraints: range: 0..2147483647 |
.1.3.6.1.4.1.2468.1.2.1.1.9.2.1.1 |
|
addrOfDevicemandatory
The ip address of the device.
|
RFC1155-SMIIpAddress Type Constraints: range: 4 |
.1.3.6.1.4.1.2468.1.2.1.1.9.2.1.2 |
|
nameOfDevicemandatory
The name/description of the device plugged into the UPS.
|
RFC1213-MIBDisplayString Constraints: range: 0-31 |
.1.3.6.1.4.1.2468.1.2.1.1.9.2.1.3 |
|
timeOfConnectionmandatory
The device registered to USHA
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.2468.1.2.1.1.9.2.1.4 |
|
timeOfConnectionTimemandatory
The device registered time to USHA.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.2468.1.2.1.1.9.2.1.5 |
|
timeOfConnectionTimeoutmandatory
The device timeout counter. Unit: 10 seconds
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2468.1.2.1.1.9.2.1.6 |
.1.3.6.1.4.1.2468.1.2.1.1.10.25
·
1 row entry
·
6 columns
Uses the ingrasys variant from
Command help
/opt/observium/mibs/ingrasys.
Walk agentConfigTrapsReceiversTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'USHA-P-MIB' -M '/opt/observium/mibs/ingrasys:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'USHA-P-MIB::agentConfigTrapsReceiversTable'
A list of managers to send traps to. The number of entries is given by the value of agentConfigNumTrapReceivers
The managers to send traps to.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
trapsIndexmandatory
The index to a trap receiver entry.
|
Integer32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.2468.1.2.1.1.10.25.1.1 |
||||||
|
trapsReceiverAddrmandatory
The IP address of the manager to send a trap to.
|
RFC1155-SMIIpAddressr/w Type Constraints: range: 4 |
.1.3.6.1.4.1.2468.1.2.1.1.10.25.1.2 |
||||||
|
receiverCommunityStringmandatory
The community name to use in the trap when
sent to the manager. |
RFC1213-MIBDisplayStringr/w Constraints: range: 0-19 |
.1.3.6.1.4.1.2468.1.2.1.1.10.25.1.3 |
||||||
|
receiverNmsTypemandatory
The trap group that NMS desired.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.2468.1.2.1.1.10.25.1.4 |
||||||
|
receiverSeverityLevelmandatory
The severity level of traps to be received by this manager.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.2468.1.2.1.1.10.25.1.5 |
||||||
|
receiverDescriptionmandatory
Description of trap receivers
|
RFC1213-MIBDisplayStringr/w Constraints: range: 0-31 |
.1.3.6.1.4.1.2468.1.2.1.1.10.25.1.6 |
.1.3.6.1.4.1.2468.1.2.1.1.10.26
·
1 row entry
·
4 columns
Uses the ingrasys variant from
Command help
/opt/observium/mibs/ingrasys.
Walk agentConfigAccessControlTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'USHA-P-MIB' -M '/opt/observium/mibs/ingrasys:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'USHA-P-MIB::agentConfigAccessControlTable'
A list of managers which can access USHA with private community string.
The managers.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
accessIndexmandatory
The index to a access control entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2468.1.2.1.1.10.26.1.1 |
||||||
|
accessControlAddrmandatory
The IP address of the manager to access USHA
|
RFC1155-SMIIpAddressr/w Type Constraints: range: 4 |
.1.3.6.1.4.1.2468.1.2.1.1.10.26.1.2 |
||||||
|
accessCommunityStringmandatory
The community name to use in the manager when
access USHA |
RFC1213-MIBDisplayStringr/w Constraints: range: 0-19 |
.1.3.6.1.4.1.2468.1.2.1.1.10.26.1.3 |
||||||
|
accessControlModemandatory
Access type, only read/Write access type can change parameter
of USHA |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.2468.1.2.1.1.10.26.1.4 |