UEC-STARLINE-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
10
Rows
10
Columns
102
.1.3.6.1.4.1.35774.2.1.2.4 · 1 row entry · 6 columns
Uses the uec variant from /opt/observium/mibs/uec.
Command help
Walk cpmAcDigitalIo
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'UEC-STARLINE-MIB' -M '/opt/observium/mibs/uec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'UEC-STARLINE-MIB::cpmAcDigitalIo'
Table of Digital I/O line data.
cpmAcDigitalIoEntry row .1.3.6.1.4.1.35774.2.1.2.4.1
Variables pertaining to Digital I/Os.
Indexes
No indexes recorded
Column Syntax OID
The index to the Digital I/O entry.
Enumeration .1.3.6.1.4.1.35774.2.1.2.4.1.1
The Digital I/O name.
DisplayStringr/w .1.3.6.1.4.1.35774.2.1.2.4.1.2
The current value of the digital I/O.
DisplayStringr/w .1.3.6.1.4.1.35774.2.1.2.4.1.3
The direction of the digital I/O.
DisplayStringr/w .1.3.6.1.4.1.35774.2.1.2.4.1.4
The active level of the digital I/O.
DisplayStringr/w .1.3.6.1.4.1.35774.2.1.2.4.1.5
Set to generate an alarm on input.
DisplayStringr/w .1.3.6.1.4.1.35774.2.1.2.4.1.6
.1.3.6.1.4.1.35774.2.1.5 · 1 row entry · 9 columns
Uses the uec variant from /opt/observium/mibs/uec.
Command help
Walk cpmAcInfeedLine
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'UEC-STARLINE-MIB' -M '/opt/observium/mibs/uec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'UEC-STARLINE-MIB::cpmAcInfeedLine'
Table of infeed line data.
cpmAcInfeedLineEntry row .1.3.6.1.4.1.35774.2.1.5.1
Variables pertaining to infeed line.
Indexes
No indexes recorded
Column Syntax OID
The index to the infeed line entry.
Enumeration .1.3.6.1.4.1.35774.2.1.5.1.1
The current measurement of infeed.
amps (rms)DisplayString .1.3.6.1.4.1.35774.2.1.5.1.3
The minimum current measured on infeed.
amps (rms)DisplayStringr/w .1.3.6.1.4.1.35774.2.1.5.1.4
The maximum current measured on infeed.
amps (rms)DisplayStringr/w .1.3.6.1.4.1.35774.2.1.5.1.5
Infeed line current rating percent of
= (current / rated current * 100).
% of ratedDisplayString .1.3.6.1.4.1.35774.2.1.5.1.6
The minimum current threshold for alarm activiation.
amps (RMS)DisplayStringr/w .1.3.6.1.4.1.35774.2.1.5.1.7
The maximum current threshold for alarm activiation.
amps (RMS)DisplayStringr/w .1.3.6.1.4.1.35774.2.1.5.1.8
The current demand of this line.
amps per demand intervalDisplayStringr/w .1.3.6.1.4.1.35774.2.1.5.1.9
The highest cpmAcInfLineCurrDemand measured
since the last operator reset of this value.
amps per demand intervalDisplayStringr/w .1.3.6.1.4.1.35774.2.1.5.1.10
.1.3.6.1.4.1.35774.2.1.6 · 1 row entry · 17 columns
Uses the uec variant from /opt/observium/mibs/uec.
Command help
Walk cpmAcInfeedPhase
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'UEC-STARLINE-MIB' -M '/opt/observium/mibs/uec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'UEC-STARLINE-MIB::cpmAcInfeedPhase'
Table of infeed phase data.
cpmAcInfeedPhaseEntry row .1.3.6.1.4.1.35774.2.1.6.1
Variables pertaining to infeed phase.
Indexes
No indexes recorded
Column Syntax OID
The index to the infeed phase entry.
Enumeration .1.3.6.1.4.1.35774.2.1.6.1.1
The current measurement of infeed.
volts (rms)DisplayString .1.3.6.1.4.1.35774.2.1.6.1.2
Phase A,B,C voltage.
volts (rms)DisplayString .1.3.6.1.4.1.35774.2.1.6.1.3
Phase A,B,C voltage minimum.
volts (rms)DisplayStringr/w .1.3.6.1.4.1.35774.2.1.6.1.4
Phase A,B,C voltage maximum.
volts (rms)DisplayStringr/w .1.3.6.1.4.1.35774.2.1.6.1.5
Phase A,B,C voltage minimum alarm threshold.
volts (rms)DisplayStringr/w .1.3.6.1.4.1.35774.2.1.6.1.6
Phase A,B,C voltage maximum alarm threshold.
volts (rms)DisplayStringr/w .1.3.6.1.4.1.35774.2.1.6.1.7
Phase A,B,C power factor.
DisplayString .1.3.6.1.4.1.35774.2.1.6.1.8
Phase A,B,C apparent power.
VADisplayString .1.3.6.1.4.1.35774.2.1.6.1.9
Phase A,B,C active power
WDisplayString .1.3.6.1.4.1.35774.2.1.6.1.10
Phase A,B,C peak active power.
WDisplayStringr/w .1.3.6.1.4.1.35774.2.1.6.1.11
Phase A,B,C reactive power.
varDisplayString .1.3.6.1.4.1.35774.2.1.6.1.12
Phase A,B,C metered energy.
kWhDisplayString .1.3.6.1.4.1.35774.2.1.6.1.13
Line-to-neutral voltage minimum.
volts (rms)DisplayStringr/w .1.3.6.1.4.1.35774.2.1.6.1.14
Line-to-neutral voltage maximum.
volts (rms)DisplayStringr/w .1.3.6.1.4.1.35774.2.1.6.1.15
Line-to-neutral voltage minimum alarm threshold.
volts (rms)DisplayStringr/w .1.3.6.1.4.1.35774.2.1.6.1.16
Line-to-neutral voltage maximum alarm threshold.
volts (rms)DisplayStringr/w .1.3.6.1.4.1.35774.2.1.6.1.17

cpmAcOutlet

table
.1.3.6.1.4.1.35774.2.1.7 · 1 row entry · 12 columns
Uses the uec variant from /opt/observium/mibs/uec.
Command help
Walk cpmAcOutlet
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'UEC-STARLINE-MIB' -M '/opt/observium/mibs/uec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'UEC-STARLINE-MIB::cpmAcOutlet'
Table of outlet data.
cpmAcOutletEntry row .1.3.6.1.4.1.35774.2.1.7.1
Variables pertaining to the outlet table.
Indexes
No indexes recorded
Column Syntax OID
The index to the outlet entry.
Enumeration .1.3.6.1.4.1.35774.2.1.7.1.1
The name assigned to this outlet.
DisplayStringr/w .1.3.6.1.4.1.35774.2.1.7.1.2
The rated current of this outlet.
amps (rms)DisplayString .1.3.6.1.4.1.35774.2.1.7.1.3
The interval of time over which the demand
is calculated for the outlet parameters.
minutesDisplayStringr/w .1.3.6.1.4.1.35774.2.1.7.1.4
The total active power being supplied by this outlet.
WDisplayString .1.3.6.1.4.1.35774.2.1.7.1.5
The peak total active power being supplied by this outlet.
WDisplayStringr/w .1.3.6.1.4.1.35774.2.1.7.1.6
The total reactive power being supplied by this outlet.
varDisplayString .1.3.6.1.4.1.35774.2.1.7.1.7
The total apparent power being supplied by this outlet.
VADisplayString .1.3.6.1.4.1.35774.2.1.7.1.8
The total power factor of this outlet.
DisplayString .1.3.6.1.4.1.35774.2.1.7.1.9
The total energy supplied by this outlet, since
the last operator reset of this cumulative value.
kWhDisplayString .1.3.6.1.4.1.35774.2.1.7.1.10
The minumum outlet current alarm threshold. Current
values below threshold will trigger an alarm.
amps (rms)DisplayStringr/w .1.3.6.1.4.1.35774.2.1.7.1.11
The maximum outlet current alarm threshold. Current
values above threshold will trigger an alarm.
amps (rms)DisplayStringr/w .1.3.6.1.4.1.35774.2.1.7.1.12
.1.3.6.1.4.1.35774.2.1.8 · 1 row entry · 9 columns
Uses the uec variant from /opt/observium/mibs/uec.
Command help
Walk cpmAcOutletLine
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'UEC-STARLINE-MIB' -M '/opt/observium/mibs/uec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'UEC-STARLINE-MIB::cpmAcOutletLine'
Table of outlet line data.
cpmAcOutletLineEntry row .1.3.6.1.4.1.35774.2.1.8.1
Variables pertaining to the outlet line table.
Indexes
No indexes recorded
Column Syntax OID
The index to the outlet entry.
Enumeration .1.3.6.1.4.1.35774.2.1.8.1.1
The index to the outlet line entry.
Enumeration .1.3.6.1.4.1.35774.2.1.8.1.2
The name assigned to this phase of the outlet.
DisplayStringr/w .1.3.6.1.4.1.35774.2.1.8.1.3
The line current flowing through this outlet.
amps (rms)DisplayString .1.3.6.1.4.1.35774.2.1.8.1.4
The percent of rated line current flowing
through this outlet.
% of ratedDisplayString .1.3.6.1.4.1.35774.2.1.8.1.5
The current demand of this outlet.
amps (rms) per demand intervalDisplayStringr/w .1.3.6.1.4.1.35774.2.1.8.1.6
The highest cpmAcOtlLineCurrDemand measured since
the last operator reset of this value.
amps (rms) per demand intervalDisplayStringr/w .1.3.6.1.4.1.35774.2.1.8.1.7
The lowest cpmAcOtlLineCurrent measured since
the last operator reset of this value.
amps (rms) per demand intervalDisplayStringr/w .1.3.6.1.4.1.35774.2.1.8.1.8
The highest cpmAcOtlLineCurrent measured since
the last operator reset of this value.
amps (rms) per demand intervalDisplayStringr/w .1.3.6.1.4.1.35774.2.1.8.1.9
.1.3.6.1.4.1.35774.2.1.12 · 1 row entry · 7 columns
Uses the uec variant from /opt/observium/mibs/uec.
Command help
Walk cpmAcTempNode
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'UEC-STARLINE-MIB' -M '/opt/observium/mibs/uec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'UEC-STARLINE-MIB::cpmAcTempNode'
Table of temperature node data.
cpmAcTempNodeEntry row .1.3.6.1.4.1.35774.2.1.12.1
Variables pertaining to the temperature node table.
Indexes
No indexes recorded
Column Syntax OID
The index to the temperature node entry.
Enumeration .1.3.6.1.4.1.35774.2.1.12.1.1
The name assigned to this temperature node.
DisplayStringr/w .1.3.6.1.4.1.35774.2.1.12.1.2
The temperature at this node.
degreesDisplayString .1.3.6.1.4.1.35774.2.1.12.1.3
The highest cpmAcNodeTemperature measured since
the last operator reset of this value.
degreesDisplayStringr/w .1.3.6.1.4.1.35774.2.1.12.1.4
The factory set system maximum temperature alarm threshold.
Values above threshold will trigger an alarm.
degreesDisplayString .1.3.6.1.4.1.35774.2.1.12.1.5
The user maximum temperature alarm threshold.
Values above threshold will trigger an alarm.
degreesDisplayStringr/w .1.3.6.1.4.1.35774.2.1.12.1.6
The battery voltage of this temperature node.
voltsDisplayString .1.3.6.1.4.1.35774.2.1.12.1.7
.1.3.6.1.4.1.35774.2.2.2.4 · 1 row entry · 6 columns
Uses the uec variant from /opt/observium/mibs/uec.
Command help
Walk cpmDcDigitalIo
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'UEC-STARLINE-MIB' -M '/opt/observium/mibs/uec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'UEC-STARLINE-MIB::cpmDcDigitalIo'
Table of Digital I/O line data.
cpmDcDigitalIoEntry row .1.3.6.1.4.1.35774.2.2.2.4.1
Variables pertaining to Digital I/Os.
Indexes
No indexes recorded
Column Syntax OID
The index to the Digital I/O entry.
Enumeration .1.3.6.1.4.1.35774.2.2.2.4.1.1
The Digital I/O name.
DisplayStringr/w .1.3.6.1.4.1.35774.2.2.2.4.1.2
The current value of the digital I/O.
DisplayStringr/w .1.3.6.1.4.1.35774.2.2.2.4.1.3
The direction of the digital I/O.
DisplayStringr/w .1.3.6.1.4.1.35774.2.2.2.4.1.4
The active level of the digital I/O.
DisplayStringr/w .1.3.6.1.4.1.35774.2.2.2.4.1.5
Set to generate an alarm on input.
DisplayStringr/w .1.3.6.1.4.1.35774.2.2.2.4.1.6
.1.3.6.1.4.1.35774.2.2.5 · 1 row entry · 18 columns
Uses the uec variant from /opt/observium/mibs/uec.
Command help
Walk cpmDcInfCircuit
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'UEC-STARLINE-MIB' -M '/opt/observium/mibs/uec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'UEC-STARLINE-MIB::cpmDcInfCircuit'
Table of infeed circuit data.
cpmDcInfCircuitEntry row .1.3.6.1.4.1.35774.2.2.5.1
Variables pertaining to infeed circuit.
Indexes
No indexes recorded
Column Syntax OID
The index to the infeed circuit entry.
Enumeration .1.3.6.1.4.1.35774.2.2.5.1.1
Circuit voltage.
volts (rms)DisplayString .1.3.6.1.4.1.35774.2.2.5.1.2
Circuit voltage minimum.
volts (rms)DisplayStringr/w .1.3.6.1.4.1.35774.2.2.5.1.3
Circuit voltage maximum.
volts (rms)DisplayStringr/w .1.3.6.1.4.1.35774.2.2.5.1.4
Circuit voltage minimum alarm threshold.
volts (rms)DisplayStringr/w .1.3.6.1.4.1.35774.2.2.5.1.5
Circuit voltage maximum alarm threshold.
volts (rms)DisplayStringr/w .1.3.6.1.4.1.35774.2.2.5.1.6
Infeed circuit power
WDisplayString .1.3.6.1.4.1.35774.2.2.5.1.7
Infeed circuit peak power.
WDisplayStringr/w .1.3.6.1.4.1.35774.2.2.5.1.8
Infeed circuit energy delivered.
kWhDisplayString .1.3.6.1.4.1.35774.2.2.5.1.9
Infeed circuit energy received.
kWhDisplayString .1.3.6.1.4.1.35774.2.2.5.1.10
The current measured on this infeed circuit.
amps (rms)DisplayString .1.3.6.1.4.1.35774.2.2.5.1.11
The minimum current measured on this infeed circuit.
amps (rms)DisplayStringr/w .1.3.6.1.4.1.35774.2.2.5.1.12
The maximum current measured on this infeed circuit.
amps (rms)DisplayStringr/w .1.3.6.1.4.1.35774.2.2.5.1.13
(current / rated current * 100) for this infeed circuit.
% of ratedDisplayString .1.3.6.1.4.1.35774.2.2.5.1.14
The minimum current threshold for alarm activiation.
amps (RMS)DisplayStringr/w .1.3.6.1.4.1.35774.2.2.5.1.15
The maximum current threshold for alarm activiation.
amps (RMS)DisplayStringr/w .1.3.6.1.4.1.35774.2.2.5.1.16
The current demand of this infeed circuit.
amps per demand intervalDisplayStringr/w .1.3.6.1.4.1.35774.2.2.5.1.17
The highest cpmDcInfCktCurrDemand measured
since the last operator reset of this value.
amps per demand intervalDisplayStringr/w .1.3.6.1.4.1.35774.2.2.5.1.18

cpmDcOutlet

table
.1.3.6.1.4.1.35774.2.2.6 · 1 row entry · 6 columns
Uses the uec variant from /opt/observium/mibs/uec.
Command help
Walk cpmDcOutlet
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'UEC-STARLINE-MIB' -M '/opt/observium/mibs/uec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'UEC-STARLINE-MIB::cpmDcOutlet'
Table of outlet data.
cpmDcOutletEntry row .1.3.6.1.4.1.35774.2.2.6.1
Variables pertaining to the outlet table.
Indexes
No indexes recorded
Column Syntax OID
The index to the outlet entry.
Enumeration .1.3.6.1.4.1.35774.2.2.6.1.1
The name assigned to this outlet.
DisplayStringr/w .1.3.6.1.4.1.35774.2.2.6.1.2
The rated current of this outlet.
amps (rms)DisplayString .1.3.6.1.4.1.35774.2.2.6.1.3
The interval of time over which the demand
is calculated for the outlet parameters.
minutesDisplayStringr/w .1.3.6.1.4.1.35774.2.2.6.1.4
The minumum outlet current alarm threshold. Current
values below threshold will trigger an alarm.
amps (rms)DisplayStringr/w .1.3.6.1.4.1.35774.2.2.6.1.5
The maximun outlet current alarm threshold. Current
values above threshold will trigger an alarm.
amps (rms)DisplayStringr/w .1.3.6.1.4.1.35774.2.2.6.1.6
.1.3.6.1.4.1.35774.2.2.7 · 1 row entry · 12 columns
Uses the uec variant from /opt/observium/mibs/uec.
Command help
Walk cpmDcOutletCircuit
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'UEC-STARLINE-MIB' -M '/opt/observium/mibs/uec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'UEC-STARLINE-MIB::cpmDcOutletCircuit'
Table of outlet circuit data.
cpmDcOutletCircuitEntry row .1.3.6.1.4.1.35774.2.2.7.1
Variables pertaining to the outlet circuit table.
Indexes
No indexes recorded
Column Syntax OID
The index to the outlet entry.
Enumeration .1.3.6.1.4.1.35774.2.2.7.1.1
The index to the outlet circuit entry.
Enumeration .1.3.6.1.4.1.35774.2.2.7.1.2
The current flowing through this outlet circuit.
amps (rms)DisplayString .1.3.6.1.4.1.35774.2.2.7.1.3
The percent of rated current flowing
through this outlet circuit.
% of ratedDisplayString .1.3.6.1.4.1.35774.2.2.7.1.4
The current demand of this outlet.
amps (rms) per demand intervalDisplayStringr/w .1.3.6.1.4.1.35774.2.2.7.1.5
The highest cpmDcOtlCktCurrentDemand measured
since the last operator reset of this value.
amps (rms) per demand intervalDisplayStringr/w .1.3.6.1.4.1.35774.2.2.7.1.6
The lowest cpmDcOtlCktCurrent measured since
the last operator reset of this value.
amps (rms) per demand intervalDisplayStringr/w .1.3.6.1.4.1.35774.2.2.7.1.7
The highest cpmDcOtlCktCurrent measured since
the last operator reset of this value.
amps (rms) per demand intervalDisplayStringr/w .1.3.6.1.4.1.35774.2.2.7.1.8
The power being supplied by this outlet circuit.
WDisplayString .1.3.6.1.4.1.35774.2.2.7.1.9
The peak power supplied by this outlet circuit.
WDisplayStringr/w .1.3.6.1.4.1.35774.2.2.7.1.10
The total energy delivered by this outlet, since
the last operator reset of this cumulative value.
kWhDisplayString .1.3.6.1.4.1.35774.2.2.7.1.11
The total energy received by this outlet, since
the last operator reset of this cumulative value.
kWhDisplayString .1.3.6.1.4.1.35774.2.2.7.1.12