This document is the SNMP MIB module for the Nokia SROS implementation
of Call Trace.
Copyright 2003-2018 Nokia. All rights reserved. Reproduction of this
document is authorized on the condition that the foregoing copyright
notice is included.
This SNMP MIB module (Specification) embodies Nokia's
proprietary intellectual property. Nokia retains all
title and ownership in the Specification, including any
revisions.
Nokia grants all interested parties a non-exclusive license to use and
distribute an unmodified copy of this Specification in connection with
management of Nokia products, and without fee, provided this copyright
notice and license appear on all copies.
This Specification is supplied `as is', and Nokia makes no warranty,
either express or implied, as to the use, operation, condition, or
performance of the Specification.
[CAUSE] This notification is triggered for the following reasons:
1) Cumulative number of call trace log files present on all cflash
cards on the active CPM that are being used for local storage
has reached the limit defined by the value of the object
tmnxCallTraceMaxFilesNumber.
2) The value of the object tmnxCallTraceMaxFilesNumber has been changed
to a value that is lower than the current cumulative number
of all call trace log files present on all cflash cards
on the active CPM that are being used for local storage.
Details about cflash cards that are being used for the local storage
of call trace log files can be found in tmnxCallTraceLocationTable.
[EFFECT] New call trace log file(s) cannot be created on any cflash
card.
[RECOVERY] Operator may execute one of the following actions to
restore the functionality:
1) Remove some call trace log files from (a) cflash card(s).
2) Increase the value of the object tmnxCallTraceMaxFilesNumber.
tmnxCallTraceLocSizeLimitReached
.1.3.6.1.4.1.6527.3.1.3.102.0.2
[CAUSE] This notification is triggered when the cumulative size of all
call trace log files on a given cflash card on the active CPM has
reached the limit specified by the value of the object
tmnxCallTraceLocationSizeLimit.
[EFFECT] New call trace log file(s) cannot be created on the impacted
cflash card.
[RECOVERY] Operator may execute one of the following actions to
restore the functionality:
1) Remove some call trace log files from the cflash card.
2) Increase the size limit (value of the object
tmnxCallTraceLocationSizeLimit) for the given cflash card.