inletTable
table.1.3.6.1.4.1.21728.4.2.1
·
1 row entry
·
22 columns
Uses the synaccess variant from
Command help
/opt/observium/mibs/synaccess.
Walk inletTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SYNLINK-MIB' -M '/opt/observium/mibs/synaccess:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SYNLINK-MIB::inletTable'
Table of all inlets entries. Inlet Entry includes information about plug type, power capacity number of poles and more.
Inlet Object for an individual inlet instance.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
| inletIndexWhich number inlet it is. | Integer32 Constraints: range: 1-256 | .1.3.6.1.4.1.21728.4.2.1.1.1 | ||||
| inletTypeDescribes which type of setup the inlet is part of. Single for one input plug. Double for two simultaneously used input plugs. ATS (Auto Transfer Switch) for 2 inputs with primary and secondary redundancy. | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.21728.4.2.1.1.2 | ||||
| inletPlugThe type of Inlet Plug Connector. | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.21728.4.2.1.1.3 | ||||
| inletNameUser defined name for Inlet | SNMPv2-TCDisplayStringr/w Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.21728.4.2.1.1.4 | ||||
| inletEnergyAccumulationkWH value to show energy consumption for inlet plug | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.21728.4.2.1.1.5 | ||||
| inletPowerFactorPower factor value for inlet plug | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.21728.4.2.1.1.6 | ||||
| inletPhasePossibilities are: Single Phase, 3 Phase Delta, or 3 Phase Wye | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.21728.4.2.1.1.7 | ||||
| inletUuidUnique identifier for Inlet | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.21728.4.2.1.1.8 | ||||
| inlet3PhaseBalancePercentage of imbalance in 3 phase inlet. Calculated with largest difference of any 2 lines, divided by average current. All times 100. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.21728.4.2.1.1.9 | ||||
| inletLine1CurrentRmsLine 1 of 3 phase inlet Current RMS in Amperes | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.21728.4.2.1.1.10 | ||||
| inletLine2CurrentRmsLine 2 of 3 phase inlet Current RMS in Amperes | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.21728.4.2.1.1.11 | ||||
| inletLine3CurrentRmsLine 3 of 3 phase inlet Current RMS in Amperes | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.21728.4.2.1.1.12 | ||||
| inletLineConfigurationApplies only to single phase. Options are L-L, L-N, or L-L\N | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.21728.4.2.1.1.13 | ||||
| inletActivePowerInlet Active Power in watts | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.21728.4.2.1.1.14 | ||||
| inletApparentPowerInlet Apparent Power in Volt-amperes (VA) | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.21728.4.2.1.1.15 | ||||
| inletReactivePowerInlet Reactive Power in Volt-Amps-Reactive (VAR) | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.21728.4.2.1.1.16 | ||||
| inletCurrentRmsInlet current draw in amps | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.21728.4.2.1.1.17 | ||||
| inletLineFrequencyInlet line frequency in hertz | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.21728.4.2.1.1.18 | ||||
| inletVoltageRmsInlet voltage RMS in volts | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.21728.4.2.1.1.19 | ||||
| atsActiveInletIf inputType is 'ats' then this value will be true if it is the currently used inlet. False if the inlet is not in use. | SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. | .1.3.6.1.4.1.21728.4.2.1.1.20 | ||||
| atsInletIdShould be A (primary) or B (secondary) for two ATS inputs | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.21728.4.2.1.1.21 | ||||
| atsInletReadyWhether the Inlet is ready to be used as a power source | SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. | .1.3.6.1.4.1.21728.4.2.1.1.22 |
bankTable
table.1.3.6.1.4.1.21728.4.4.1
·
1 row entry
·
15 columns
Uses the synaccess variant from
Command help
/opt/observium/mibs/synaccess.
Walk bankTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SYNLINK-MIB' -M '/opt/observium/mibs/synaccess:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SYNLINK-MIB::bankTable'
Table of bank instances.
Bank object for a particular outlet bank.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
| bankIndexWhich number bank it is. | Integer32 Constraints: range: 1-256 | .1.3.6.1.4.1.21728.4.4.1.1.1 | ||||
| bankUuidUnique Identifier for Bank | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.21728.4.4.1.1.2 | ||||
| bankOutletSwitchingSupportedDescribes if bank outlets have relays for switching | SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. | .1.3.6.1.4.1.21728.4.4.1.1.3 | ||||
| bankOutletMeteringSupportedDescribes if bank outlets can measure individual outlet current in amps | SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. | .1.3.6.1.4.1.21728.4.4.1.1.4 | ||||
| bankCurrentRmsCurrent RMS of all outlets on bank in Amperes. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.21728.4.4.1.1.5 | ||||
| bankVoltageVoltage of bank. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.21728.4.4.1.1.6 | ||||
| bankLineFrequencyLine Frequency of bank. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.21728.4.4.1.1.7 | ||||
| bankPowerFactorBank Power factor | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.21728.4.4.1.1.8 | ||||
| bankLinesSpecific Lines or line configuration which this bank is utilizing | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.21728.4.4.1.1.9 | ||||
| bankActivePowerActive Power of bank. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.21728.4.4.1.1.10 | ||||
| bankReactivePowerReactive Power of bank. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.21728.4.4.1.1.11 | ||||
| bankApparentPowerApparent Power of bank. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.21728.4.4.1.1.12 | ||||
| bankNameUser defined bank name. | SNMPv2-TCDisplayStringr/w Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.21728.4.4.1.1.13 | ||||
| bankBreakerSupportedTrue if bank has an associated over current protector. | SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. | .1.3.6.1.4.1.21728.4.4.1.1.14 | ||||
| bankBreakerStateTrue if breaker is working and not considered 'tripped' | SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. | .1.3.6.1.4.1.21728.4.4.1.1.15 |
outletTable
table.1.3.6.1.4.1.21728.4.5.1
·
1 row entry
·
6 columns
Uses the synaccess variant from
Command help
/opt/observium/mibs/synaccess.
Walk outletTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SYNLINK-MIB' -M '/opt/observium/mibs/synaccess:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SYNLINK-MIB::outletTable'
Table of outlet instances.
Outlet object for a particular input line.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
| outletIndexWhich number outlet it is. | Integer32 Constraints: range: 1-256 | .1.3.6.1.4.1.21728.4.5.1.1.1 | ||||
| outletUuidUnique identifier for outlet | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.21728.4.5.1.1.2 | ||||
| outletNameUser defined name for outlet. | SNMPv2-TCDisplayStringr/w Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.21728.4.5.1.1.3 | ||||
| outletCurrentRmsCurrent RMS in Amperes for individual outlet if supported. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.21728.4.5.1.1.6 | ||||
| outletStateState of relay. '0' means outlet is off (relay is open). '1' means outlet is on (relay is closed). Set '2' to power cycle outlet. | RelayEnumerationr/w Type Values:
| .1.3.6.1.4.1.21728.4.5.1.1.7 | ||||
| outletConnectorType of Outlet Receptacle. | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.21728.4.5.1.1.8 |
groupTable
table.1.3.6.1.4.1.21728.4.6.1
·
1 row entry
·
6 columns
Uses the synaccess variant from
Command help
/opt/observium/mibs/synaccess.
Walk groupTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SYNLINK-MIB' -M '/opt/observium/mibs/synaccess:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SYNLINK-MIB::groupTable'
Table of all outlet groups entries.
Group Object for a group of outlets.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
| groupIndexWhich number group it is. | Integer32 Constraints: range: 1-256 | .1.3.6.1.4.1.21728.4.6.1.1.1 | ||||
| groupNameUser defined name for group | SNMPv2-TCDisplayStringr/w Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.21728.4.6.1.1.2 | ||||
| groupUuidUnique identifier for group | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.21728.4.6.1.1.3 | ||||
| groupSetStateSet all outlets within state to given state. On for on, off for off. | SNMPv2-TCTruthValuer/w Type Values:
Description: Represents a boolean value. | .1.3.6.1.4.1.21728.4.6.1.1.4 | ||||
| groupRebootReboot all outlets within a group | SNMPv2-TCTruthValuer/w Type Values:
Description: Represents a boolean value. | .1.3.6.1.4.1.21728.4.6.1.1.5 | ||||
| groupCurrentRmsCurrent RMS sum of all outlet current measurements. Available only of outlet metering supported. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.21728.4.6.1.1.6 |
sensorTable
table.1.3.6.1.4.1.21728.4.7.1
·
1 row entry
·
7 columns
Uses the synaccess variant from
Command help
/opt/observium/mibs/synaccess.
Walk sensorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SYNLINK-MIB' -M '/opt/observium/mibs/synaccess:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SYNLINK-MIB::sensorTable'
Table of Sensor entries.
Sensor instance.
Indexes
| Column | Syntax | OID |
|---|---|---|
| sensorIndexNumber of sensor | Integer32 Constraints: range: 1-256 | .1.3.6.1.4.1.21728.4.7.1.1.1 |
| sensorTypeType of sensor. hum_temp for humidity & temp sensor | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.21728.4.7.1.1.2 |
| sensorTempTemperature if supported in celsius. sensorTempOffset is added to raw value to generate output of this OID. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.21728.4.7.1.1.3 |
| sensorHumidityHumidity if supported in percentage humidity. sensorHumidityOffset is added to raw value to generate output of this OID. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.21728.4.7.1.1.4 |
| sensorTempOffsetOffset for temperature. Signed value. | SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.21728.4.7.1.1.5 |
| sensorHumidityOffsetOffset for humidity. Signed Value | SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.21728.4.7.1.1.6 |
| sensorNameUser defined name for sensor | SNMPv2-TCDisplayStringr/w Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.21728.4.7.1.1.7 |
powerLogTable
table.1.3.6.1.4.1.21728.4.8.1
·
1 row entry
·
3 columns
Uses the synaccess variant from
Command help
/opt/observium/mibs/synaccess.
Walk powerLogTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SYNLINK-MIB' -M '/opt/observium/mibs/synaccess:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SYNLINK-MIB::powerLogTable'
Table of all logging metric related to power
Instance of logging metric
Indexes
| Column | Syntax | OID |
|---|---|---|
| pwrLogIndexID for log entry | Integer32 Constraints: range: 1-256 | .1.3.6.1.4.1.21728.4.8.1.1.1 |
| pwrLogTypeType of logging metric. Can be | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.21728.4.8.1.1.2 |
| pwrLogValueVarious types. Current values. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.21728.4.8.1.1.3 |
environmentLogTable
table.1.3.6.1.4.1.21728.4.8.2
·
1 row entry
·
3 columns
Uses the synaccess variant from
Command help
/opt/observium/mibs/synaccess.
Walk environmentLogTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SYNLINK-MIB' -M '/opt/observium/mibs/synaccess:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SYNLINK-MIB::environmentLogTable'
Table of all logging metric related to temperature and humidity
Instance of logging metric
Indexes
| Column | Syntax | OID |
|---|---|---|
| envLogIndexID for log entry | Integer32 Constraints: range: 1-256 | .1.3.6.1.4.1.21728.4.8.2.1.1 |
| envLogTypeType of logging metric. Can be temp or humidity | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.21728.4.8.2.1.2 |
| envLogValueEither temp in celsius or humidity in percentage | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.21728.4.8.2.1.3 |
eventTriggerTable
table.1.3.6.1.4.1.21728.4.9.2.1
·
1 row entry
·
9 columns
Uses the synaccess variant from
Command help
/opt/observium/mibs/synaccess.
Walk eventTriggerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SYNLINK-MIB' -M '/opt/observium/mibs/synaccess:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SYNLINK-MIB::eventTriggerTable'
Table of all Event Triggers
Instance of Event Trigger
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
| eventTriggerIndexID for event trigger entry | Integer32 Constraints: range: 1-256 | .1.3.6.1.4.1.21728.4.9.2.1.1.1 | ||||
| eventTypeType of event. Can be any of traps. (Show Table) | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.21728.4.9.2.1.1.2 | ||||
| eventCodeUnique code for event | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.21728.4.9.2.1.1.3 | ||||
| eventNameUsed defined name for event trigger. | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.21728.4.9.2.1.1.4 | ||||
| eventTriggerAttr1First Attribute. See Event Table for details on specified Attr. | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.21728.4.9.2.1.1.5 | ||||
| eventTriggerAttr2Second Attribute. See Event Table for details on specified Attr. | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.21728.4.9.2.1.1.6 | ||||
| eventTriggerAttr3Third Attribute. See Event Table for details on specified Attr. | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.21728.4.9.2.1.1.7 | ||||
| eventIsTriggeredDescribes whether or not the trigger has met it's threshold | SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. | .1.3.6.1.4.1.21728.4.9.2.1.1.8 | ||||
| eventTriggeredTimeTime in seconds that this event has been triggered | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.21728.4.9.2.1.1.9 |