STORMSHIELD-HA-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
5
Rows
5
Columns
26

snsNodeTable

table
.1.3.6.1.4.1.11256.1.11.7 · 1 row entry · 11 columns
Uses the stormshield variant from /opt/observium/mibs/stormshield.
Command help
Walk snsNodeTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'STORMSHIELD-HA-MIB' -M '/opt/observium/mibs/stormshield:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'STORMSHIELD-HA-MIB::snsNodeTable'
Firewalls part of the HA cluster
snsNode row .1.3.6.1.4.1.11256.1.11.7.1
HA node
Indexes
Column Syntax OID
snsNodeIndexIndex of each line in tableInteger32
Constraints:
range: 0-1
.1.3.6.1.4.1.11256.1.11.7.1.1
snsFwSerialFirewall serialRFC1213-MIBDisplayString.1.3.6.1.4.1.11256.1.11.7.1.2
snsOnlineFirewall is onlineSNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.11256.1.11.7.1.3
snsModelFirewall modelRFC1213-MIBDisplayString.1.3.6.1.4.1.11256.1.11.7.1.4
snsVersionFirewall firmware versionRFC1213-MIBDisplayString.1.3.6.1.4.1.11256.1.11.7.1.5
snsHALicenceHA LicenceRFC1213-MIBDisplayString.1.3.6.1.4.1.11256.1.11.7.1.6
snsHAQualityHA QualitySNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11256.1.11.7.1.7
snsHAPriorityHA PrioritySNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11256.1.11.7.1.8
snsHAStatusForcedHA status forced (-2 : Unknown forced status,
-1 : No peer found, 0 : No forced status,
1 : Forced active, 2 : Forced passive)
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11256.1.11.7.1.9
snsHAActiveIs the firewall active ?SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.11256.1.11.7.1.10
snsHAUptimeFirewall uptimeSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11256.1.11.7.1.11
.1.3.6.1.4.1.11256.1.11.10 · 1 row entry · 3 columns
Uses the stormshield variant from /opt/observium/mibs/stormshield.
Command help
Walk snsNodePowerSupplyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'STORMSHIELD-HA-MIB' -M '/opt/observium/mibs/stormshield:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'STORMSHIELD-HA-MIB::snsNodePowerSupplyTable'
Power supply status of Firewalls
snsNodePowerSupplyEntry row .1.3.6.1.4.1.11256.1.11.10.1
Power supply information
Column Syntax OID
snsNodePowerSupplyIndexIndex of each line in tableInteger32
Constraints:
range: 0-255
.1.3.6.1.4.1.11256.1.11.10.1.1
snsNodePowerSupplyPoweredPower supply is powered by electricity ?SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.11256.1.11.10.1.2
snsNodePowerSupplyStatusWhat is the status of the power supply ?RFC1213-MIBDisplayString.1.3.6.1.4.1.11256.1.11.10.1.3
.1.3.6.1.4.1.11256.1.11.11 · 1 row entry · 6 columns
Uses the stormshield variant from /opt/observium/mibs/stormshield.
Command help
Walk snsNodeDiskTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'STORMSHIELD-HA-MIB' -M '/opt/observium/mibs/stormshield:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'STORMSHIELD-HA-MIB::snsNodeDiskTable'
Disks status of Firewalls
snsNodeDiskEntry row .1.3.6.1.4.1.11256.1.11.11.1
Disk information
Column Syntax OID
snsNodeDiskIndexIndex of each disk in tableInteger32
Constraints:
range: 0-255
.1.3.6.1.4.1.11256.1.11.11.1.1
snsNodeDiskNameMount point nameRFC1213-MIBDisplayString.1.3.6.1.4.1.11256.1.11.11.1.2
snsNodeDiskSmartResultResult of the smart infos testsRFC1213-MIBDisplayString.1.3.6.1.4.1.11256.1.11.11.1.3
snsNodeDiskIsRaidIs the disk a member of a RAID arrayInteger32
Constraints:
range: 0-1
.1.3.6.1.4.1.11256.1.11.11.1.4
snsNodeDiskRaidStatusRAID StatusRFC1213-MIBDisplayString.1.3.6.1.4.1.11256.1.11.11.1.5
snsNodeDiskPositionDisk PositionRFC1213-MIBDisplayString.1.3.6.1.4.1.11256.1.11.11.1.6
.1.3.6.1.4.1.11256.1.11.12 · 1 row entry · 2 columns
Uses the stormshield variant from /opt/observium/mibs/stormshield.
Command help
Walk snsNodeCpuTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'STORMSHIELD-HA-MIB' -M '/opt/observium/mibs/stormshield:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'STORMSHIELD-HA-MIB::snsNodeCpuTable'
Cpus status of Firewalls
snsNodeCpuEntry row .1.3.6.1.4.1.11256.1.11.12.1
CPU information
Column Syntax OID
snsNodeCpuIndexIndex of each cpu in tableInteger32
Constraints:
range: 0-255
.1.3.6.1.4.1.11256.1.11.12.1.1
snsNodeCpuTempTemperature in Celsius degreeSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11256.1.11.12.1.2
.1.3.6.1.4.1.11256.1.11.13 · 1 row entry · 4 columns
Uses the stormshield variant from /opt/observium/mibs/stormshield.
Command help
Walk snsNodeFanTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'STORMSHIELD-HA-MIB' -M '/opt/observium/mibs/stormshield:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'STORMSHIELD-HA-MIB::snsNodeFanTable'
Fans status of Firewalls
snsNodeFanEntry row .1.3.6.1.4.1.11256.1.11.13.1
CPU information
Column Syntax OID
snsNodeFanIndexEach line in the tableInteger32
Constraints:
range: 0-255
.1.3.6.1.4.1.11256.1.11.13.1.1
snsNodeFanNameName of the FanRFC1213-MIBDisplayString.1.3.6.1.4.1.11256.1.11.13.1.2
snsNodeFanStatusStatus of the FanRFC1213-MIBDisplayString.1.3.6.1.4.1.11256.1.11.13.1.3
snsNodeFanRpmSpeed of the FanUnsigned32
Constraints:
range: 0-4294967295
.1.3.6.1.4.1.11256.1.11.13.1.4