h trap signifies that a process managed by PM
has crashed and left a core file. The variable sent with
the notification indicates which process crashed.
admissionMemError
.1.3.6.1.4.1.17163.1.52.4.0.10
ssure is high. No additional connections will be
optimized
graniteLunError
.1.3.6.1.4.1.17163.1.52.4.0.10000
LUN module encountered error.
graniteISCSIError
.1.3.6.1.4.1.17163.1.52.4.0.10001
iSCSI module encountered error.
graniteSnapshotError
.1.3.6.1.4.1.17163.1.52.4.0.10003
Snapshot module encountered error.
graniteBlockstoreError
.1.3.6.1.4.1.17163.1.52.4.0.10004
Blockstore module encountered error.
graniteCoreError
.1.3.6.1.4.1.17163.1.52.4.0.10005
SteelFusion Core module encountered error.
graniteUncommittedDataError
.1.3.6.1.4.1.17163.1.52.4.0.10006
The level of uncommitted data is too high.
graniteHighAvailabilityError
.1.3.6.1.4.1.17163.1.52.4.0.10007
High availability module encountered error.
graniteApplianceUnlicensedError
.1.3.6.1.4.1.17163.1.52.4.0.10009
Appliance license expired/invalid.
cpuUtilClear
.1.3.6.1.4.1.17163.1.52.4.0.1003
e CPU utilization has fallen back
within the acceptable threshold
pagingActivityClear
.1.3.6.1.4.1.17163.1.52.4.0.1004
The system has stopped paging excessively (thrashing)
peerVersionMismatchClear
.1.3.6.1.4.1.17163.1.52.4.0.1006
All peers are compatible
bypassModeClear
.1.3.6.1.4.1.17163.1.52.4.0.1007
Traffic is now being optimized
raidErrorClear
.1.3.6.1.4.1.17163.1.52.4.0.1008
A RAID error has been cleared
storeCorruptionClear
.1.3.6.1.4.1.17163.1.52.4.0.1009
The data store is normal
admissionMemErrorClear
.1.3.6.1.4.1.17163.1.52.4.0.1010
control memory alarm has been cleared,
and the optimization service is running normally
admissionConnErrorClear
.1.3.6.1.4.1.17163.1.52.4.0.1011
control connections alarm has been cleared,
and the service is running normally
haltErrorClear
.1.3.6.1.4.1.17163.1.52.4.0.1012
The service is now running normally
serviceErrorClear
.1.3.6.1.4.1.17163.1.52.4.0.1013
The service is now running normally
linkErrorClear
.1.3.6.1.4.1.17163.1.52.4.0.1017
An interface on the appliance has regained its link
nfsV2V4Clear
.1.3.6.1.4.1.17163.1.52.4.0.1018
NFS v2/v4 alarm has been cleared
powerSupplyErrorClear
.1.3.6.1.4.1.17163.1.52.4.0.1019
All power supplies are now functioning normally
asymRouteErrorClear
.1.3.6.1.4.1.17163.1.52.4.0.1020
All asymmetric routes have expired or have been cleared
fanErrorClear
.1.3.6.1.4.1.17163.1.52.4.0.1021
All system fans are now functioning normally
memoryErrorClear
.1.3.6.1.4.1.17163.1.52.4.0.1022
A memory error has been rectified on the appliance
ipmiClear
.1.3.6.1.4.1.17163.1.52.4.0.1023
An IPMI event has been rectified on the appliance
temperatureNormal
.1.3.6.1.4.1.17163.1.52.4.0.1026
The system temperature is back within the threshold
temperatureNonCritical
.1.3.6.1.4.1.17163.1.52.4.0.1027
The system temperature is no longer in a critical stage
cfConnRestored
.1.3.6.1.4.1.17163.1.52.4.0.1028
Connection reestablished with the specified neighbor
cfConnLostEosClear
.1.3.6.1.4.1.17163.1.52.4.0.1029
reestablished after a prior termination due to
receiving end of stream from the specified neighbor
cfConnLostErrClear
.1.3.6.1.4.1.17163.1.52.4.0.1030
restablished after a prior termination due to
an error communicating with the specified neighbor
cfKeepaliveTimeoutClear
.1.3.6.1.4.1.17163.1.52.4.0.1031
Keepalive restored after a prior timeout with the specified neighbor
cfAckTimeoutClear
.1.3.6.1.4.1.17163.1.52.4.0.1032
Ack restored after a prior timeout with the specified neighbor
cfReadInfoTimeoutClear
.1.3.6.1.4.1.17163.1.52.4.0.1033
ly read info from the specified neighbor after a prior
timeout
cfLatencyExceededClear
.1.3.6.1.4.1.17163.1.52.4.0.1034
forwarding latency with the specified neighbor
is back within the threshold
sslPeeringSCEPAutoReenrollClear
.1.3.6.1.4.1.17163.1.52.4.0.1035
Automatic re-enrollment of SSL peering certificate is OK or is disabled
crlClear
.1.3.6.1.4.1.17163.1.52.4.0.1036
crl polling is running normally
datastoreSyncFailureClear
.1.3.6.1.4.1.17163.1.52.4.0.1037
Data store sync restored
secureVaultClear
.1.3.6.1.4.1.17163.1.52.4.0.1040
Secure vault has been unlocked and is healthy
diskErrorClear
.1.3.6.1.4.1.17163.1.52.4.0.1045
All disks are back online
admissionCpuErrorClear
.1.3.6.1.4.1.17163.1.52.4.0.1052
control CPU alarm has been cleared,
and the service is running normally
admissionTcpErrorClear
.1.3.6.1.4.1.17163.1.52.4.0.1053
control TCP alarm has been cleared,
and the service is running normally
systemDiskFullErrorClear
.1.3.6.1.4.1.17163.1.52.4.0.1054
The system partitions are below usage thresholds
domainJoinErrorClear
.1.3.6.1.4.1.17163.1.52.4.0.1055
A domain error on the appliance has been cleared
certsExpiringErrorClear
.1.3.6.1.4.1.17163.1.52.4.0.1056
There are no expiring certificates
licenseErrorClear
.1.3.6.1.4.1.17163.1.52.4.0.1057
The main appliance license error has been cleared
hardwareErrorClear
.1.3.6.1.4.1.17163.1.52.4.0.1058
Hardware Error has been cleared
sysdetailErrorClear
.1.3.6.1.4.1.17163.1.52.4.0.1059
Overall status of System Detail Report is back to OK
admissionMapiErrorClear
.1.3.6.1.4.1.17163.1.52.4.0.1060
System will resume to optimize new MAPI connections since connection count has fallen below the threshold
neighborIncompatibilityClear
.1.3.6.1.4.1.17163.1.52.4.0.1061
Serial cascade misconfiguration issue is now resolved.
flashErrorClear
.1.3.6.1.4.1.17163.1.52.4.0.1062
Flash is back to OK.
lanWanLoopClear
.1.3.6.1.4.1.17163.1.52.4.0.1063
op error cleared. System will resume to optimize connect
ions.
optimizationServiceStatusClear
.1.3.6.1.4.1.17163.1.52.4.0.1064
on Service error cleared. System will resume to optimize
connections.
upgradeFailureClear
.1.3.6.1.4.1.17163.1.52.4.0.1065
ilure cleared and the system is still running
the previous image
clusterDisconnectedSHAlertClear
.1.3.6.1.4.1.17163.1.52.4.0.1068
All cluster Steelheads are currently connected
smbAlertClear
.1.3.6.1.4.1.17163.1.52.4.0.1069
Domain authentication alert has been cleared
linkDuplexClear
.1.3.6.1.4.1.17163.1.52.4.0.1070
An interface on the appliance has cleared the half-duplex error
linkIoErrorsClear
.1.3.6.1.4.1.17163.1.52.4.0.1071
An interface on the appliance has cleared the I/O errors state
clusterIpv6IncompatiblePeerClear
.1.3.6.1.4.1.17163.1.52.4.0.1074
All cluster Steelheads are IPv6 compatible
pathSelectionPathDownClear
.1.3.6.1.4.1.17163.1.52.4.0.1077
Path Selection - A path came back up
clusterNeighborIncompatibleClear
.1.3.6.1.4.1.17163.1.52.4.0.1080
All cluster Steelheads are compatible
secureTransportControllerConnected
.1.3.6.1.4.1.17163.1.52.4.0.1081
Steelhead successfully connected to Secure Transport controller
secureTransportRegistrationSucceeded
.1.3.6.1.4.1.17163.1.52.4.0.1082
Steelhead successfully registered with Secure Transport controller
pathSelectionPathProbingErrorClear
.1.3.6.1.4.1.17163.1.52.4.0.1083
Path Selection - No paths have probing errors
webProxyConfigAlarmClear
.1.3.6.1.4.1.17163.1.52.4.0.1084
Web Proxy Service Configuration Alarm cleared
webProxyServiceAlarmClear
.1.3.6.1.4.1.17163.1.52.4.0.1085
Web Proxy Service Status Alarm cleared
admissionConnError
.1.3.6.1.4.1.17163.1.52.4.0.11
limit reached. No additional connections will be
optimized
graniteLunClear
.1.3.6.1.4.1.17163.1.52.4.0.11000
LUN module error cleared.
graniteISCSIClear
.1.3.6.1.4.1.17163.1.52.4.0.11001
iSCSI module error cleared.
graniteSnapshotClear
.1.3.6.1.4.1.17163.1.52.4.0.11003
Snapshot module error cleared.
graniteBlockstoreClear
.1.3.6.1.4.1.17163.1.52.4.0.11004
Blockstore module error cleared.
graniteCoreClear
.1.3.6.1.4.1.17163.1.52.4.0.11005
SteelFusion Core module error cleared.
graniteUncommittedDataClear
.1.3.6.1.4.1.17163.1.52.4.0.11006
The level of uncommitted data has returned to normal.
graniteHighAvailabilityClear
.1.3.6.1.4.1.17163.1.52.4.0.11007
High availability module error cleared.
graniteApplianceUnlicensedClear
.1.3.6.1.4.1.17163.1.52.4.0.11009
Appliance license active.
haltError
.1.3.6.1.4.1.17163.1.52.4.0.12
The service is halted due to a software error
serviceError
.1.3.6.1.4.1.17163.1.52.4.0.13
been a non-fatal optimization service error.
Please consult the log file
scheduledJobError
.1.3.6.1.4.1.17163.1.52.4.0.14
A scheduled job has failed during execution
confModeEnter
.1.3.6.1.4.1.17163.1.52.4.0.15
A user has entered configuration mode
confModeExit
.1.3.6.1.4.1.17163.1.52.4.0.16
A user has exited configuration mode
linkError
.1.3.6.1.4.1.17163.1.52.4.0.17
An interface on the appliance has lost its link
nfsV2V4
.1.3.6.1.4.1.17163.1.52.4.0.18
NFS v2/v4 alarm notification
powerSupplyError
.1.3.6.1.4.1.17163.1.52.4.0.19
A power supply on the appliance has failed
procExit
.1.3.6.1.4.1.17163.1.52.4.0.2
trap signifies that a process managed by PM
has exited unexpectedly, but not left a core file.
The variable sent with the notification indicates
which process exited.
asymRouteError
.1.3.6.1.4.1.17163.1.52.4.0.20
routes have been detected,certain connections might
not have been optimized because of this.
fanError
.1.3.6.1.4.1.17163.1.52.4.0.21
A fan has failed on this appliance
memoryError
.1.3.6.1.4.1.17163.1.52.4.0.22
A memory error has been detected on the appliance
ipmi
.1.3.6.1.4.1.17163.1.52.4.0.23
ent has been detected on the appliance. Please check
the details in the alarm report on the web UI
configChange
.1.3.6.1.4.1.17163.1.52.4.0.24
A change has been made to the system's configuration
datastoreWrapped
.1.3.6.1.4.1.17163.1.52.4.0.25
The datastore has wrapped around
temperatureWarning
.1.3.6.1.4.1.17163.1.52.4.0.26
The system temperature has exceeded the threshold
temperatureCritical
.1.3.6.1.4.1.17163.1.52.4.0.27
The system temperature has reached a critical stage
cfConnFailure
.1.3.6.1.4.1.17163.1.52.4.0.28
Unable to establish connection with the specified neighbor
cfConnLostEos
.1.3.6.1.4.1.17163.1.52.4.0.29
lost since end of stream was received from the
specified neighbor
cpuUtil
.1.3.6.1.4.1.17163.1.52.4.0.3
e CPU utilization in the past minute has gone
above the acceptable threshold
cfConnLostErr
.1.3.6.1.4.1.17163.1.52.4.0.30
lost due to an error communicating with the
specified neighbor
hypervisorHardwareMgmtConnectionError
.1.3.6.1.4.1.17163.1.52.4.0.30002
Hypervisor hardware management connection alarm is triggered.
hypervisorHardwarePowerError
.1.3.6.1.4.1.17163.1.52.4.0.30003
Hypervisor hardware power alarm is triggered.
hypervisorHardwareMemoryError
.1.3.6.1.4.1.17163.1.52.4.0.30005
Hypervisor hardware memory error alarm is triggered.
hypervisorHardwareOtherHardwareError
.1.3.6.1.4.1.17163.1.52.4.0.30006
Hypervisor other hardware error alarm is triggered.
hypervisorHardwareTemperatureError
.1.3.6.1.4.1.17163.1.52.4.0.30007
Hypervisor hardware temperature alarm is triggered.
hypervisorLicenseError
.1.3.6.1.4.1.17163.1.52.4.0.30008
Hypervisor license alarm is triggered.
hypervisorOperationError
.1.3.6.1.4.1.17163.1.52.4.0.30009
Hypervisor alarm is triggered.
vspConnectionError
.1.3.6.1.4.1.17163.1.52.4.0.30010
VSP connection alarm is triggered.
vspInstallationError
.1.3.6.1.4.1.17163.1.52.4.0.30011
VSP installation alarm is triggered.
vspLicenseError
.1.3.6.1.4.1.17163.1.52.4.0.30012
Riverbed VSP vSphere license alarm is triggered.
vspBaseLicenseError
.1.3.6.1.4.1.17163.1.52.4.0.30013
Riverbed VSP base license alarm is triggered.
cfKeepaliveTimeout
.1.3.6.1.4.1.17163.1.52.4.0.31
lost due to lack of keepalives from the specified
neighbor