SDH-ETS-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
14
Rows
14
Columns
188

spiTTPTable

table
.1.3.6.1.4.1.1038.110.10.2 · 1 row entry · 12 columns
Uses the sagemcom variant from /opt/observium/mibs/sagemcom.
Command help
Walk spiTTPTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SDH-ETS-MIB' -M '/opt/observium/mibs/sagemcom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SDH-ETS-MIB::spiTTPTable'
List of synchronous physical interface in equipment.
spiTTPEntry row .1.3.6.1.4.1.1038.110.10.2.1
A particular synchronous physical interface of the equipment.
Indexes
Column Syntax OID
A unique value which identify a particular
synchronous physical interface.
The value of this index is a constant value assigned to an entry at
equipment design time. It is usualy related to harware.
Exemple:
For ADR155c…
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.10.2.1.1
The STM-n level of the interface.
STMLevel
Type Values:
1stm1
4stm4
16stm16
64stm64
.1.3.6.1.4.1.1038.110.10.2.1.2
The kind of the interface: electrical or optical
SpiTTPType
Type Values:
0electrical
1optical
.1.3.6.1.4.1.1038.110.10.2.1.3
A text string which identifies the particular entry among the
synchronous physical interface entries.
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.1038.110.10.2.1.4
Index of the Board that supports the physical acces
of this interface. This index refers to another MIB that defines
the board
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.10.2.1.5
Friendly Index of the physical acces on the Board that supports
the interface
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.10.2.1.6
When the value of this field is set to false, the failure detection
is stopped for this synchronous physical interface.
EQUIPMENT-MIBSagemBooleanr/w
Type Values:
1true
2false
.1.3.6.1.4.1.1038.110.10.2.1.7
Active failures on synchronous physical interface
SpiTTPFailure
Type Values:
0none
1los
2tf
3losTf
.1.3.6.1.4.1.1038.110.10.2.1.8
Severity associed with active failure for synchronous physical interface.
EQUIPMENT-MIBSeverity
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.10.2.1.9
This field gives the active loopback status on the
synchronous physical interface.
When its value is `line' the data flow recieved from the port side
is sent back to the line.
When its value is `equipment' the data flow…
Loopbackr/w
Type Values:
0none
1line
2equipment
3lineEquipement
.1.3.6.1.4.1.1038.110.10.2.1.10
Severity associed with Loss Of Signal failure
for synchronous physical interface.
EQUIPMENT-MIBSeverityr/w
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.10.2.1.20
Severity associed with Tranmit Fail failure
for synchronous physical interface.
EQUIPMENT-MIBSeverityr/w
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.10.2.1.21

rsTTPTable

table
.1.3.6.1.4.1.1038.110.20.2 · 1 row entry · 12 columns
Uses the sagemcom variant from /opt/observium/mibs/sagemcom.
Command help
Walk rsTTPTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SDH-ETS-MIB' -M '/opt/observium/mibs/sagemcom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SDH-ETS-MIB::rsTTPTable'
List of regenerator section terminaison in equipment.
rsTTPEntry row .1.3.6.1.4.1.1038.110.20.2.1
A particular regenerator section terminaison of the equipment.
Indexes
Column Syntax OID
A unique value which identify a particular
synchronous physical interface.
The value of this index is always the same as spiTTPIndex.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.20.2.1.1
When the value of this field is set to false, the failure detection
is stopped for this regenerator section terminaison.
EQUIPMENT-MIBSagemBooleanr/w
Type Values:
1true
2false
.1.3.6.1.4.1.1038.110.20.2.1.2
A text string which identifies the particular entry among the
regenerator section terminaison entries.
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.1038.110.20.2.1.3
Active failures on regenerator section terminaison
RsTTPFailure
Type Values:
0none
1lof
.1.3.6.1.4.1.1038.110.20.2.1.4
Severity associed active Failure for regenerator section terminaison.
EQUIPMENT-MIBSeverity
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.20.2.1.5
Mode used for EOW: Codir or contradir Master
EOWMode
Type Values:
0codirectional
1contradirectional
.1.3.6.1.4.1.1038.110.20.2.1.8
A reference to the object which sends the data flow to
E1 RSOH byte (index in X21 table)
Usualy E1 carries X21 EOW (engineering order wire) data
and thus the pointer s value reference a mib X21 port entry.
Zero indicate…
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.20.2.1.9
A reference to the object which sends the data flow to
F1 RSOH byte.Zero indicates not used
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.20.2.1.10
The number of errors above which the second is declared
severely errored for this interface/function.
This value apply for near and far interface/function
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.20.2.1.11
The line determines the SOH byte selected for Engineering
Order Wire: SOH starts with 3 lines of RSOH (1,2,3) and
finish with 5 lines of MSOH (5,6,7,8,9)
E1 is on line 2 column 4.
Zero indicates EOW not used, value …
Integer32r/w
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.20.2.1.12
The column determines the SOH byte selected for Engineering
Order Wire: SOH is composed of Col [1,9]
E1 is on line 2 column 4.
Zero indicates EOW not used, value different from 4 means EOW
not on E1
Integer32r/w
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.20.2.1.13
Severity associed with Loss Of Frame failure
for regenerator section terminaison.
EQUIPMENT-MIBSeverityr/w
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.20.2.1.20

msTTPTable

table
.1.3.6.1.4.1.1038.110.30.2 · 1 row entry · 16 columns
Uses the sagemcom variant from /opt/observium/mibs/sagemcom.
Command help
Walk msTTPTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SDH-ETS-MIB' -M '/opt/observium/mibs/sagemcom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SDH-ETS-MIB::msTTPTable'
List of multiplex section terminaison in equipment.
msTTPEntry row .1.3.6.1.4.1.1038.110.30.2.1
A particular multiplex section terminaison of the equipment.
Indexes
Column Syntax OID
A unique value which identify a particular
synchronous physical interface.
The value of this index is always the same as spiTTPIndex
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.30.2.1.1
The value of this field indicates the kind of wanted multiplex section protection.
The default value is NONE.
if value is changed in msp(1) or msSPRing(2) then (if it's possible) an entry is created
respectivelly in msp…
ProtectionTyper/w
Type Values:
0none
1msp
2msSPRing
.1.3.6.1.4.1.1038.110.30.2.1.2
When the value of this field is set to false, the failure detection
is stopped for this multiplex section terminaison.
EQUIPMENT-MIBSagemBooleanr/w
Type Values:
1true
2false
.1.3.6.1.4.1.1038.110.30.2.1.3
A text string which identifies the particular entry among the
multiplex section terminaison entries.
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.1038.110.30.2.1.4
Active failures on multiplex section terminaison
MsTTPFailure
Type Values:
0none
1ais
2eber
4sd
8rdi
12sdRdi
.1.3.6.1.4.1.1038.110.30.2.1.5
Severity associed with active failures on multiplex section terminaison.
EQUIPMENT-MIBSeverity
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.30.2.1.6
Mode used for EOW: Codir or contradir Master
EOWMode
Type Values:
0codirectional
1contradirectional
.1.3.6.1.4.1.1038.110.30.2.1.7
A reference to the object which sends the data flow to
E2 MSOH byte.
Usualy E2 carries X21 EOW (engineering order wire) data.
The reference is an index in X21 table.Zero indicates not used
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.30.2.1.8
The line determines the SOH byte selected for Engineering
Order Wire: SOH starts with 3 lines of RSOH (1,2,3) and
finish with 5 lines of MSOH (5,6,7,8,9)
E2 is on line 9 column 7.
Zero indicates not used, v…
Integer32r/w
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.30.2.1.9
The column determines the SOH byte selected for Engineering
Order Wire: SOH is composed of Col [1,9]
E2 is on line 9 column 7.
Zero indicates EOW not used, value different from 7 means EOW
not on E2
Integer32r/w
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.30.2.1.10
If the value of this field is true, the eber is monitored and is used as
MSP and SETS criterium.
If this defect is detected, an ais signal is send downstream and
rdi upstream.
EQUIPMENT-MIBSagemBooleanr/w
Type Values:
1true
2false
.1.3.6.1.4.1.1038.110.30.2.1.11
A Signal Degrade failure is declared if the error block rate is
greater than 1E(-mstSdThreshold).
The Signal Degrade failure desapeared when the error block rate is
less than 1E(1 - mstSdThreshold).
Integer32r/w
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.30.2.1.12
The number of errors above which the second is declared
severely errored for this interface/function.
This value apply for near and far interface/function
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.30.2.1.13
Severity associed with Excecive Bit Error Rate failure
for multiplex section terminaison.
EQUIPMENT-MIBSeverityr/w
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.30.2.1.20
Severity associed with Signal Degrade failure
for multiplex section terminaison.
EQUIPMENT-MIBSeverityr/w
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.30.2.1.21
Severity associed with Remote Defect Indication failure
for multiplex section terminaison.
EQUIPMENT-MIBSeverityr/w
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.30.2.1.22

msaTable

table
.1.3.6.1.4.1.1038.110.60.2 · 1 row entry · 13 columns
Uses the sagemcom variant from /opt/observium/mibs/sagemcom.
Command help
Walk msaTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SDH-ETS-MIB' -M '/opt/observium/mibs/sagemcom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SDH-ETS-MIB::msaTable'
List of multiplex section adaptation in equipment.
msaEntry row .1.3.6.1.4.1.1038.110.60.2.1
A particular multiplex section adaptation of the equipment.
Indexes
Column Syntax OID
Index of a particular entry among the
multiplex section adaptation entries.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.60.2.1.1
The STM-n level of the multiplex section adaptation.
STMLevel
Type Values:
1stm1
4stm4
16stm16
64stm64
.1.3.6.1.4.1.1038.110.60.2.1.2
Type of msa sinkPointer: msa or mst
MsaSinkType
Type Values:
0msa
1mst
.1.3.6.1.4.1.1038.110.60.2.1.3
A reference to the object which sends the data flow to this
function on synchronous port interface side.
In most equipments, this value cannot be changed and points to
the MST it is hard wired with.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.60.2.1.4
A text string which identifies the particular entry among the
multiplex section adaptation entries.
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.1038.110.60.2.1.5
Type of msa srcPointer: msa or vc4
MsaSrcType
Type Values:
0none
1msa
2vc4
.1.3.6.1.4.1.1038.110.60.2.1.6
Type of msa srcPointer: msa or vc4
MsaSrcType
Type Values:
0none
1msa
2vc4
.1.3.6.1.4.1.1038.110.60.2.1.7
Type of msa srcPointer: msa or vc4
MsaSrcType
Type Values:
0none
1msa
2vc4
.1.3.6.1.4.1.1038.110.60.2.1.8
Type of msa srcPointer: msa or vc4
MsaSrcType
Type Values:
0none
1msa
2vc4
.1.3.6.1.4.1.1038.110.60.2.1.9
Table index of the object which sends the data flow to this
function on equipment side.
For STM16: 4 pseudo STM4 (group of 4STM1) identified by their
index in msaTable. Theses indexes must be differents to thoses
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.60.2.1.10
A reference to the object which sends the data flow to this
function on equipment side.
In most equipments, this value cannot be changed and points to
the VC4 function it is hard wired with.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.60.2.1.11
A reference to the object which sends the data flow to this
function on equipment side.
In most equipments, this value cannot be changed and points to
the VC4 function it is hard wired with.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.60.2.1.12
A reference to the object which sends the data flow to this
function on equipment side.
In most equipments, this value cannot be changed and points to
the VC4 function it is hard wired with.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.60.2.1.13

au4CTPTable

table
.1.3.6.1.4.1.1038.110.70.2 · 1 row entry · 10 columns
Uses the sagemcom variant from /opt/observium/mibs/sagemcom.
Command help
Walk au4CTPTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SDH-ETS-MIB' -M '/opt/observium/mibs/sagemcom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SDH-ETS-MIB::au4CTPTable'
List of administrative unit order 4 in equipment which are availables for new connection or 
used in connection. In that case, an indication on the connection type is set 
into the au4CTPCnxType Variable.
All au4 CTP, which are made up of lower connection level (tu3 or tu12), are set to 'used' value with 
'tu' type connection indication .
au4CTPEntry row .1.3.6.1.4.1.1038.110.70.2.1
A particular administrative unit order 4 of the equipment.
Indexes
Column Syntax OID
A unique value which identify a particular
administrative unit order 4.
The value of index is a constant assigned to an entry at
equipment design time. It is usualy related to harware.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.70.2.1.1
au4 connection point Status: free or used.
The 'free' value is used when there is no connection with this output CTP
CTPStatus
Type Values:
0free
1used
.1.3.6.1.4.1.1038.110.70.2.1.2
au4 connection Type: none, au4, au4-4c,au4-16c,tu.
The 'none' value is used when there is no connection with this output CTP
Au4CTPCnxType
Type Values:
0none
1au
4au4c
16au16c
20tu
.1.3.6.1.4.1.1038.110.70.2.1.3
A text string which identifies the particular entry among the
administrative unit order 4 entries.
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.1038.110.70.2.1.4
When the value of this field is set to false, the failure detection
is stopped for this administrative unit order 4.
EQUIPMENT-MIBSagemBooleanr/w
Type Values:
1true
2false
.1.3.6.1.4.1.1038.110.70.2.1.6
Active failures on administrative unit order 4
Au4CTPFailure
Type Values:
0none
1ais
2lop
3lom
.1.3.6.1.4.1.1038.110.70.2.1.7
A reference to failure severity for administrative unit order 4.
EQUIPMENT-MIBSeverity
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.70.2.1.8
Severity associed with Alarme Indication Signal failure
for administrative unit order 4.
EQUIPMENT-MIBSeverityr/w
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.70.2.1.20
Severity associed with Loss Of Pointer failure
for administrative unit order 4.
EQUIPMENT-MIBSeverityr/w
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.70.2.1.21
Severity associed with Loss Of MultiFrame failure
for administrative unit order 4.
EQUIPMENT-MIBSeverityr/w
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.70.2.1.22

vc4TTPTable

table
.1.3.6.1.4.1.1038.110.100.2 · 1 row entry · 23 columns
Uses the sagemcom variant from /opt/observium/mibs/sagemcom.
Command help
Walk vc4TTPTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SDH-ETS-MIB' -M '/opt/observium/mibs/sagemcom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SDH-ETS-MIB::vc4TTPTable'
List of virtual container order 4 in equipment.The number of records depends on the kinds of
configured boards
vc4TTPEntry row .1.3.6.1.4.1.1038.110.100.2.1
A particular virtual container order 4 of the equipment.
Indexes
Column Syntax OID
A unique value which identify a particular
virtual container order 4.
The value of index is a constant assigned to an entry at
equipment design time. It is usualy related to harware.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.100.2.1.1
A reference to the object which sends the data flow to this
function on synchronous or unsynchronous port interface side.
This pointer corresponds to an index in the msTTPTable or nspiTTPTable.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.100.2.1.2
A reference to the kind of the sink Pointer
Vc4TTPSinkType
Type Values:
1mst
2nspi
.1.3.6.1.4.1.1038.110.100.2.1.3
A text string which identifies the particular entry among the
virtual container order 4 entries.
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.1038.110.100.2.1.5
When the value of this field is set to false, the failure detection
is stopped for this virtual container order 4.
EQUIPMENT-MIBSagemBooleanr/w
Type Values:
1true
2false
.1.3.6.1.4.1.1038.110.100.2.1.6
Active failures on virtual container order 4
Vc4TTPFailure
Type Values:
0none
1rdi
2sd
3sdRdi
4uneq
6uneqSd
8plm
9plmRdi
10plmSd
11plmRdiSd
16tim
17timRdi
18timSd
19timRdiSd
.1.3.6.1.4.1.1038.110.100.2.1.7
A reference to failure severity for virtual container order 4.
EQUIPMENT-MIBSeverity
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.100.2.1.8
Configuration of the pathTrace length (1 byte or 16 bytes).
Vc4TTPTraceModer/w
Type Values:
1size1
16size16
.1.3.6.1.4.1.1038.110.100.2.1.9
The path trace is a user string that always follows the vc4.
If the value the received path trace does not match this one, a
tim (Trail Identifier Mismatch) failure is issued.
The value `? ' match all possi…
OctetStringr/w
Constraints:
range: 16-16
.1.3.6.1.4.1.1038.110.100.2.1.11
The path trace is a user string that always follows the vc4.
The value of this field is sent in j1 byte as path trace for this vc4.
The default value is `all 0'.
OctetStringr/w
Constraints:
range: 16-16
.1.3.6.1.4.1.1038.110.100.2.1.12
The path trace is a user string that always follows the vc4.
The value is the actual path trace received in j1 byte
OctetString
Constraints:
range: 16-16
.1.3.6.1.4.1.1038.110.100.2.1.13
The signal label indicates the multiplexing structure of the vc4.
If the signal label received for this vc4 is not null and does
not match this field, a Signal Label Mismatch failure is detected.
If the received label i…
Vc4TTPSignalLabel
Type Values:
0unequiped
1unspecified
2tug
255all1
.1.3.6.1.4.1.1038.110.100.2.1.14
The signal label indicates the multiplexing structure of the vc4.
The value of this field in sent as signal label for the vc4.
Vc4TTPSignalLabelr/w
Type Values:
0unequiped
1unspecified
2tug
255all1
.1.3.6.1.4.1.1038.110.100.2.1.15
The signal label indicates the multiplexing structure of the vc4.
The value of this field is the actual received signal label
for this vc4
Vc4TTPSignalLabel
Type Values:
0unequiped
1unspecified
2tug
255all1
.1.3.6.1.4.1.1038.110.100.2.1.16
A Signal Degrade failure is declared if the error block rate is
greater than 1E(-SdThreshold).
The Signal Degrade failure desapeared when the error block rate is
less than 1E(1 - SdThreshold).
Integer32r/w
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.100.2.1.17
The number of errors above which the second is declared
severely errored for this interface/function.
This value apply for near and far interface/function
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.100.2.1.18
If set to false the equipment does not send Remote Defect Indication.
EQUIPMENT-MIBSagemBooleanr/w
Type Values:
1true
2false
.1.3.6.1.4.1.1038.110.100.2.1.19
Severity associed with Remote Defect Indication failure
for virtual container order 4.
EQUIPMENT-MIBSeverityr/w
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.100.2.1.20
Severity associed with Signal Degrade failure
for virtual container order 4.
EQUIPMENT-MIBSeverityr/w
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.100.2.1.21
Severity associed with virtual container UNEQuiped failure
for virtual container order 4.
EQUIPMENT-MIBSeverityr/w
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.100.2.1.22
Severity associed with Path Label Mismatch failure
for virtual container order 4.
EQUIPMENT-MIBSeverityr/w
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.100.2.1.23
If set to true the equipment does not manage the Tim Failure.
EQUIPMENT-MIBSagemBooleanr/w
Type Values:
1true
2false
.1.3.6.1.4.1.1038.110.100.2.1.24
Severity associed with Trail Identifier Mismatch failure
for virtual container order 4.
EQUIPMENT-MIBSeverityr/w
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.100.2.1.25

tu3CTPTable

table
.1.3.6.1.4.1.1038.110.120.2 · 1 row entry · 8 columns
Uses the sagemcom variant from /opt/observium/mibs/sagemcom.
Command help
Walk tu3CTPTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SDH-ETS-MIB' -M '/opt/observium/mibs/sagemcom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SDH-ETS-MIB::tu3CTPTable'
List of tributary units order 3 in equipment which are availables for new connection or used in
the same connection level. In that case, an indication on the connection point status is set into the 
tu3CTPStatus Variable.
 All tu3 CTP, which are involved in different connection level (tu12 or au4), disappear from
 this List.
tu3CTPEntry row .1.3.6.1.4.1.1038.110.120.2.1
A particular tributary unit of the equipment.
Indexes
Column Syntax OID
Index that identifies the particular entry among the
tributary unit entries.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.120.2.1.1
tu3 connection point Status: free or used.
The 'free' value is used when there is no connection with this output CTP
CTPStatus
Type Values:
0free
1used
.1.3.6.1.4.1.1038.110.120.2.1.2
A text string which identifies the particular entry among the
tributary unit entries.
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.1038.110.120.2.1.5
When the value of this field is set to false, the failure detection
is stopped for this tributary unit.
EQUIPMENT-MIBSagemBooleanr/w
Type Values:
1true
2false
.1.3.6.1.4.1.1038.110.120.2.1.6
Active failures on tributary unit
Tu3CTPFailure
Type Values:
0none
1ais
2lop
.1.3.6.1.4.1.1038.110.120.2.1.7
A reference to failure severity for tributary unit.
EQUIPMENT-MIBSeverity
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.120.2.1.8
Severity associed with Alarme Indication Signal failure
for tributary unit.
EQUIPMENT-MIBSeverityr/w
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.120.2.1.20
Severity associed with Loss Of Pointer failure
for tributary unit.
EQUIPMENT-MIBSeverityr/w
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.120.2.1.21

vc3TTPTable

table
.1.3.6.1.4.1.1038.110.130.2 · 1 row entry · 21 columns
Uses the sagemcom variant from /opt/observium/mibs/sagemcom.
Command help
Walk vc3TTPTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SDH-ETS-MIB' -M '/opt/observium/mibs/sagemcom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SDH-ETS-MIB::vc3TTPTable'
List of virtual container order 3 in equipment.The number of records depends on the kinds of
configured boards
vc3TTPEntry row .1.3.6.1.4.1.1038.110.130.2.1
A particular virtual container order 3 of the equipment.
Indexes
Column Syntax OID
A unique value which identify a particular
virtual container order 3.
The value of index is a constant assigned to an entry at
equipment design time. It is usualy related to harware.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.130.2.1.1
A reference to the object which sends the data flow to this
function on non-sdh physical port side.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.130.2.1.2
A reference to the kind of the sink Pointer
Vc3TTPSinkType
Type Values:
1vc4
2nspi
.1.3.6.1.4.1.1038.110.130.2.1.3
A text string which identifies the particular entry among the
virtual container order 3 entries.
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.1038.110.130.2.1.5
When the value of this field is set to false, the failure detection
is stopped for this virtual container order 3.
EQUIPMENT-MIBSagemBooleanr/w
Type Values:
1true
2false
.1.3.6.1.4.1.1038.110.130.2.1.6
Active failures on virtual container order 3
VcLoFailure
Type Values:
0none
1rdi
2sd
3sdRdi
4uneq
6uneqSd
8plm
9plmRdi
10plmSd
11plmRdiSd
16tim
17timRdi
18timSd
19timRdiSd
.1.3.6.1.4.1.1038.110.130.2.1.7
A reference to failure severity for virtual container order 3.
EQUIPMENT-MIBSeverity
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.130.2.1.8
The path trace is a user string that always follows the vc3.
If the value the received path trace does not match this one, a
tim (Trail Identifier Mismatch) failure is issued.
The value `? ' match all possi…
OctetStringr/w
Constraints:
range: 16-16
.1.3.6.1.4.1.1038.110.130.2.1.9
The path trace is a user string that always follows the vc3.
The value of this field is sent in j1 byte as path trace for this vc3.
The default value is `all 0'.
OctetStringr/w
Constraints:
range: 1-15
.1.3.6.1.4.1.1038.110.130.2.1.10
The path trace is a user string that always follows the vc3.
The value is the actual path trace received in j1 byte
OctetString
Constraints:
range: 15-15
.1.3.6.1.4.1.1038.110.130.2.1.11
The signal label indicates the multiplexing structure of the vc3.
Usualy the value of this field cannot be modified as most equipment
use the asynchronous bit multiplexing.
For historical reasons the receipt of label `u…
Vc3TTPSignalLabel
Type Values:
0unequiped
1unspecified
4mapping3445
7all1
.1.3.6.1.4.1.1038.110.130.2.1.12
The signal label indicates the multiplexing structure of the vc3.
The value of this field is sent as signal label for the vc3.
The unspecified value is used for compatibilty with old sdh
equipments.
The `unequiped' valu…
Vc3TTPSignalLabelr/w
Type Values:
0unequiped
1unspecified
4mapping3445
7all1
.1.3.6.1.4.1.1038.110.130.2.1.13
The signal label indicates the multiplexing structure of the vc3.
The value of this field is the actual received signal label
for this vc3
Vc3TTPSignalLabel
Type Values:
0unequiped
1unspecified
4mapping3445
7all1
.1.3.6.1.4.1.1038.110.130.2.1.14
A Signal Degrade failure is declared if the error block rate is
greater than 1E(-SdThreshold).
The Signal Degrade failure desapeared when the error block rate is
less than 1E(1 - SdThreshold).
Integer32r/w
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.130.2.1.15
The number of errors above which the second is declared
severely errored for this interface/function.
This value apply for near and far interface/function
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.130.2.1.16
If set to false the equipment does not send Remote Defect Indication.
EQUIPMENT-MIBSagemBooleanr/w
Type Values:
1true
2false
.1.3.6.1.4.1.1038.110.130.2.1.17
Severity associed with Remote Defect Indication failure
for virtual container order 3.
EQUIPMENT-MIBSeverityr/w
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.130.2.1.20
Severity associed with Signal Degrade failure
for virtual container order 3.
EQUIPMENT-MIBSeverityr/w
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.130.2.1.21
Severity associed with virtual container UNEQuiped failure
for virtual container order 3.
EQUIPMENT-MIBSeverityr/w
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.130.2.1.22
Severity associed with Path Label Mismatch failure
for virtual container order 3.
EQUIPMENT-MIBSeverityr/w
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.130.2.1.23
Severity associed with Trail Identifier Mismatch failure
for virtual container order 3.
EQUIPMENT-MIBSeverityr/w
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.130.2.1.24

tu12CTPTable

table
.1.3.6.1.4.1.1038.110.140.2 · 1 row entry · 8 columns
Uses the sagemcom variant from /opt/observium/mibs/sagemcom.
Command help
Walk tu12CTPTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SDH-ETS-MIB' -M '/opt/observium/mibs/sagemcom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SDH-ETS-MIB::tu12CTPTable'
List of tributary unit order 12 in equipment which are availables for new connection or 
used in the same connection level. In that case, an indication on the connection point Status
is set into the tu12CTPStatus Variable.
All tu12 CTP, which are involved in a different connection level (tu3 or au4), disappear from
this List.
tu12CTPEntry row .1.3.6.1.4.1.1038.110.140.2.1
A particular tributary unit of the equipment.
Indexes
Column Syntax OID
A unique value which identify a particular tu12.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.140.2.1.1
tu12 connection point Status: free or used.
The 'free' value is used when there is no connection with this output CTP
CTPStatus
Type Values:
0free
1used
.1.3.6.1.4.1.1038.110.140.2.1.2
A text string which identifies the particular entry among the
tributary unit entries.
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.1038.110.140.2.1.5
When the value of this field is set to false, the failure detection
is stopped for this tributary unit.
EQUIPMENT-MIBSagemBooleanr/w
Type Values:
1true
2false
.1.3.6.1.4.1.1038.110.140.2.1.6
Active failures on tributary unit
Tu12CTPFailure
Type Values:
0none
1ais
2lop
.1.3.6.1.4.1.1038.110.140.2.1.7
A reference to failure severity for tributary unit.
EQUIPMENT-MIBSeverity
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.140.2.1.8
Severity associed with Alarme Indication Signal failure
for tributary unit.
EQUIPMENT-MIBSeverityr/w
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.140.2.1.20
Severity associed with Loss Of Pointer failure
for tributary unit.
EQUIPMENT-MIBSeverityr/w
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.140.2.1.21

vc12TTPTable

table
.1.3.6.1.4.1.1038.110.150.2 · 1 row entry · 21 columns
Uses the sagemcom variant from /opt/observium/mibs/sagemcom.
Command help
Walk vc12TTPTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SDH-ETS-MIB' -M '/opt/observium/mibs/sagemcom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SDH-ETS-MIB::vc12TTPTable'
List of virtual container order 12 in equipment.The number of records depends on the kinds of
configured boards
vc12TTPEntry row .1.3.6.1.4.1.1038.110.150.2.1
A particular virtual container order 12 of the equipment.
Indexes
Column Syntax OID
A unique value which identify a particular
virtual container order 12.
The value of index is a constant assigned to an entry at
equipment design time. It is usualy related to harware.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.150.2.1.1
A reference to the object which sends the data flow to this
function on non-sdh physical port side.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.150.2.1.2
A reference to the kind of the sink Pointer
Vc12TTPSinkType
Type Values:
1vc4
2nspi
.1.3.6.1.4.1.1038.110.150.2.1.3
A text string which identifies the particular entry among the
virtual container order 12 entries.
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.1038.110.150.2.1.5
When the value of this field is set to false, the failure detection
is stopped for this virtual container order 12.
EQUIPMENT-MIBSagemBooleanr/w
Type Values:
1true
2false
.1.3.6.1.4.1.1038.110.150.2.1.6
Active failures on virtual container order 12
VcLoFailure
Type Values:
0none
1rdi
2sd
3sdRdi
4uneq
6uneqSd
8plm
9plmRdi
10plmSd
11plmRdiSd
16tim
17timRdi
18timSd
19timRdiSd
.1.3.6.1.4.1.1038.110.150.2.1.7
A reference to failure severity for virtual container order 12.
EQUIPMENT-MIBSeverity
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.150.2.1.8
The path trace is a user string that always follows the vc12.
If the value the received path trace does not match this one, a
tim (Trail Identifier Mismatch) failure is issued.
The value `? ' match all poss…
OctetStringr/w
Constraints:
range: 16-16
.1.3.6.1.4.1.1038.110.150.2.1.9
The path trace is a user string that always follows the vc12.
The value of this field is sent in j2 byte as path trace for this vc12.
The default value is `all 0'.
OctetStringr/w
Constraints:
range: 16-16
.1.3.6.1.4.1.1038.110.150.2.1.10
The path trace is a user string that always follows the vc12.
The value is the actual path trace received in j2 byte
OctetString
Constraints:
range: 16-16
.1.3.6.1.4.1.1038.110.150.2.1.11
The signal label indicates the multiplexing structure of the vc12.
Usualy the value of this field cannot be modified as most equipment
use the asynchronous bit multiplexing.
For historical reasons the receipt of label `…
Vc12TTPSignalLabel
Type Values:
0unequiped
1unspecified
2asyncBit
7all1
.1.3.6.1.4.1.1038.110.150.2.1.12
The signal label indicates the multiplexing structure of the vc12.
The value of this field is sent as signal label for the vc12.
The unspecified value is used for compatibilty with old sdh
equipments.
The `unequiped' va…
Vc12TTPSignalLabelr/w
Type Values:
0unequiped
1unspecified
2asyncBit
7all1
.1.3.6.1.4.1.1038.110.150.2.1.13
The signal label indicates the multiplexing structure of the vc12.
The value of this field is the actual received signal label
for this vc12
Vc12TTPSignalLabel
Type Values:
0unequiped
1unspecified
2asyncBit
7all1
.1.3.6.1.4.1.1038.110.150.2.1.14
A Signal Degrade failure is declared if the error block rate is
greater than 1E(-SdThreshold).
The Signal Degrade failure desapeared when the error block rate is
less than 1E(1 - SdThreshold).
Integer32r/w
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.150.2.1.15
The number of errors above which the second is declared
severely errored for this interface/function.
This value apply for near and far interface/function
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.150.2.1.16
If set to false the equipment does not send Remote Defect Indication.
EQUIPMENT-MIBSagemBooleanr/w
Type Values:
1true
2false
.1.3.6.1.4.1.1038.110.150.2.1.17
Severity associed with Remote Defect Indication failure
for virtual container order 12.
EQUIPMENT-MIBSeverityr/w
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.150.2.1.20
Severity associed with Signal Degrade failure
for virtual container order 12.
EQUIPMENT-MIBSeverityr/w
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.150.2.1.21
Severity associed with virtual container UNEQuiped failure
for virtual container order 12.
EQUIPMENT-MIBSeverityr/w
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.150.2.1.22
Severity associed with Path Label Mismatch failure
for virtual container order 12.
EQUIPMENT-MIBSeverityr/w
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.150.2.1.23
Severity associed with Trail Identifier Mismatch failure
for virtual container order 12.
EQUIPMENT-MIBSeverityr/w
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.150.2.1.24

nspiCTPTable

table
.1.3.6.1.4.1.1038.110.160.2 · 1 row entry · 4 columns
Uses the sagemcom variant from /opt/observium/mibs/sagemcom.
Command help
Walk nspiCTPTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SDH-ETS-MIB' -M '/opt/observium/mibs/sagemcom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SDH-ETS-MIB::nspiCTPTable'
List of non-sdh physical port in equipment.
nspiCTPEntry row .1.3.6.1.4.1.1038.110.160.2.1
A particular non-sdh physical port of the equipment.
Indexes
Column Syntax OID
A unique value which identify a particular
non-sdh physical port.
The value of index is a constant assigned to an entry at
equipment design time. It is usualy related to harware.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.160.2.1.1
The type of VC which is associated to the nspi interface.
NspiSrcType
Type Values:
1vc12
2vc3
3vc4
4channel
.1.3.6.1.4.1.1038.110.160.2.1.2
nspi connection point Status: free or used.
The 'free' value is used when there is no connection with this output CTP
CTPStatus
Type Values:
0free
1used
.1.3.6.1.4.1.1038.110.160.2.1.3
A text string which identifies the particular entry among the
non-sdh physical port entries.
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.1038.110.160.2.1.4

nspiTTPTable

table
.1.3.6.1.4.1.1038.110.170.2 · 1 row entry · 14 columns
Uses the sagemcom variant from /opt/observium/mibs/sagemcom.
Command help
Walk nspiTTPTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SDH-ETS-MIB' -M '/opt/observium/mibs/sagemcom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SDH-ETS-MIB::nspiTTPTable'
List of non-sdh physical port in equipment.
nspiTTPEntry row .1.3.6.1.4.1.1038.110.170.2.1
A particular non-sdh physical port of the equipment.
Indexes
Column Syntax OID
A unique value which identify a particular
non-sdh physical port.
The value of index is a constant assigned to an entry at
equipment design time. It is usualy related to harware.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.170.2.1.1
The type of media for the nspi interface.
NspiTTPType
Type Values:
1g703R75ohm
2g703R120ohm
10x21
20ethernet
30atm
.1.3.6.1.4.1.1038.110.170.2.1.2
The rate level of the nspi interface.
NspiTTPLevel
Type Values:
2rate2Mb
10rate10Mb
34rate34Mb
45rate45Mb
100rate100Mb
140rate140Mb
1000rate1Gb
.1.3.6.1.4.1.1038.110.170.2.1.3
A text string which identifies the particular entry among the
non-sdh physical port entries.
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.1038.110.170.2.1.4
Index of the Board that supports the physical acces
of this interface
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.170.2.1.5
Friendly Index of the physical acces on the Board that supports
the interface
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.170.2.1.6
A reference to the type of object which sends the data flow to this
interface. Usually the value is vc12, vc3 or vc4 types.
NspiSrcType
Type Values:
1vc12
2vc3
3vc4
4channel
.1.3.6.1.4.1.1038.110.170.2.1.7
A reference to the object which sends the data flow to this
interface. Usually the value is the Index of a vc12, vc3 or vc4.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.170.2.1.8
When the value of this field is set to false, the failure detection
is stopped for this non-sdh physical port.
EQUIPMENT-MIBSagemBooleanr/w
Type Values:
1true
2false
.1.3.6.1.4.1.1038.110.170.2.1.9
Active failures on non-sdh physical port
NspiTTPFailure
Type Values:
0none
1los
2ais
.1.3.6.1.4.1.1038.110.170.2.1.10
A reference to failure severity for non-sdh physical port.
EQUIPMENT-MIBSeverity
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.170.2.1.11
This field gives the active loopback status on the
non-sdh physical port.
When its value is `line' the data flow recieved from the port side
is sent back to the line.
When its value is `equipment' the data flow recieved…
Loopbackr/w
Type Values:
0none
1line
2equipment
3lineEquipement
.1.3.6.1.4.1.1038.110.170.2.1.14
Severity associed with Loss Of Signal failure
for non-sdh physical port.
EQUIPMENT-MIBSeverityr/w
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.170.2.1.20
Severity associed with Alarme Indication Signal failure
for non-sdh physical port.
EQUIPMENT-MIBSeverityr/w
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.170.2.1.21

channelTable

table
.1.3.6.1.4.1.1038.110.180.2 · 1 row entry · 16 columns
Uses the sagemcom variant from /opt/observium/mibs/sagemcom.
Command help
Walk channelTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SDH-ETS-MIB' -M '/opt/observium/mibs/sagemcom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SDH-ETS-MIB::channelTable'
List of SDH Channels in equipment.
channelEntry row .1.3.6.1.4.1.1038.110.180.2.1
A particular SDH Channel of the equipment.
Indexes
Column Syntax OID
A unique value which identify a particular
SDH Channel.
The value of index is a constant assigned to an entry at
equipment design time. It is usualy related to harware.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.180.2.1.1
The type of encapsulation used to map Data stream into Sdh containers
ChannelEncapsr/w
Type Values:
0none
1atm
2pos
3gfp
.1.3.6.1.4.1.1038.110.180.2.1.2
Number of VC4 into the channel.
Integer32r/w
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.180.2.1.5
Number of VC3 into the channel.
Integer32r/w
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.180.2.1.6
Number of VC12 into the channel.
Integer32r/w
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.180.2.1.7
The type of Concatenation used within the channel
ChannelConcatr/w
Type Values:
0none
1virtual
2contiguous
.1.3.6.1.4.1.1038.110.180.2.1.8
The desired state of the channel. The
testing(3) state indicates that no operational
packets can be passed.
Enumerationr/w
Enumerated Values:
1up
2down
3testing
.1.3.6.1.4.1.1038.110.180.2.1.9
The current operational state of the channel.
The testing(3) state indicates that no operational
packets can be passed.
Enumeration
Enumerated Values:
1up
2down
3testing
.1.3.6.1.4.1.1038.110.180.2.1.10
Index of the first Vc in the Channel when it is configured.
Otherwise this field is set to 0.
Integer32r/w
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.180.2.1.11
This field give the maximum delay (in millisecondes) for receiving virtual concatenated frames.
This field is set to 0 when channelConcat is different to virtual(1)
Integer32r/w
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.180.2.1.12
When the value of this field is set to false, the failure detection
is stopped for this channel.
EQUIPMENT-MIBSagemBooleanr/w
Type Values:
1true
2false
.1.3.6.1.4.1.1038.110.180.2.1.13
Active failures on channel
ChannelFailure
Type Values:
0none
1loa
2lom
3sqm
.1.3.6.1.4.1.1038.110.180.2.1.14
A reference to failure severity for non-sdh physical port.
EQUIPMENT-MIBSeverity
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.180.2.1.15
Severity associated with Loss Of Alignment failure
for channel.
EQUIPMENT-MIBSeverityr/w
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.180.2.1.16
Severity associated with Loss Of Multiframe failure
for channel.
EQUIPMENT-MIBSeverityr/w
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.180.2.1.17
Severity associated with Sequence Mismatch failure
for channel.
EQUIPMENT-MIBSeverityr/w
Type Values:
1nonAlarmed
2minor
3major
4critical
5warning
6invNonAlarmed
7invMinor
8invMajor
9invCritical
10invWarning
.1.3.6.1.4.1.1038.110.180.2.1.18
.1.3.6.1.4.1.1038.110.190.2 · 1 row entry · 10 columns
Uses the sagemcom variant from /opt/observium/mibs/sagemcom.
Command help
Walk bandwidthTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SDH-ETS-MIB' -M '/opt/observium/mibs/sagemcom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SDH-ETS-MIB::bandwidthTable'
List of Bandwidth units in equipment. It represent the bandwidth occupation of each non-sdh card
bandwidthEntry row .1.3.6.1.4.1.1038.110.190.2.1
A particular unit part of a non-sdh card bandwidth.
Indexes
Column Syntax OID
A unique value which identify a particular unit of a non-sdh card bandwidth.
The value of index is a Vc Index which change when bandwidthSrcType value is modified.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.190.2.1.1
Index of the Board that supports the bandwidth unit.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.190.2.1.2
Define the decomposition level of the bandwidth.
NspiSrcTyper/w
Type Values:
1vc12
2vc3
3vc4
4channel
.1.3.6.1.4.1.1038.110.190.2.1.3
this field is set to bandwidthIndex when the unit is used by a channel and set to 0 otherwise.
It defines the TTP and CTP index associated to the channel.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.190.2.1.4
A reference to the kind of the sink Pointer. Usually the value is Channel.
NspiSrcTyper/w
Type Values:
1vc12
2vc3
3vc4
4channel
.1.3.6.1.4.1.1038.110.190.2.1.5
A reference to the object which sends the data flow to this
function on unsynchronous port interface side.
This pointer corresponds to an index in the channelTable.
Integer32r/w
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.190.2.1.6
The desired state of the Vc. The
testing(3) state indicates that no operational
packets can be passed.
Enumerationr/w
Enumerated Values:
1up
2down
3testing
.1.3.6.1.4.1.1038.110.190.2.1.7
The current operational state of the Vc.
The testing(3) state indicates that no operational
packets can be passed.
Enumeration
Enumerated Values:
1up
2down
3testing
.1.3.6.1.4.1.1038.110.190.2.1.8
A reference to the previous VC into the channel. This field is set to 0 if the VC is not
associated to a channel or if it is the first Vc of the channel.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.190.2.1.9
A reference to the next VC into the channel. This field is set to 0 if the VC is not
associated to a channel or if it is the last Vc of the channel.
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.1038.110.190.2.1.10