SCTE-HMS-HE-RF-AMP-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
2
Rows
2
Columns
7
.1.3.6.1.4.1.5591.1.11.4.1.1.1.1 · 1 row entry · 3 columns
Uses the scte variant from /opt/observium/mibs/scte.
Command help
Walk heRFAmpUnitTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SCTE-HMS-HE-RF-AMP-MIB' -M '/opt/observium/mibs/scte:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SCTE-HMS-HE-RF-AMP-MIB::heRFAmpUnitTable'
A table containing information about RF Amp used
in an indoor environment.
heRFAmpUnitEntry row .1.3.6.1.4.1.5591.1.11.4.1.1.1.1.1
List of information about each RF Amp.
Column Syntax OID
This controls and/or reports the amplifier
control mode.
none - no automatic control provided
alc - automatic level control
asc - automatic slope control
agc - automatic gain control
alsc - automatic level slope control
Enumerationr/w
Enumerated Values:
1none
2alc
3asc
4agc
5alsc
.1.3.6.1.4.1.5591.1.11.4.1.1.1.1.1.1
This controls and reports the setting of an attenuator
in the amplifier RF chain.
SCTE-HMS-HEADENDIDENT-MIBHeTenthdBr/w .1.3.6.1.4.1.5591.1.11.4.1.1.1.1.1.2
This controls and reports the slope setting of the amplifier.
SCTE-HMS-HEADENDIDENT-MIBHeTenthdBr/w .1.3.6.1.4.1.5591.1.11.4.1.1.1.1.1.3
.1.3.6.1.4.1.5591.1.11.4.1.1.1.2 · 1 row entry · 4 columns
Uses the scte variant from /opt/observium/mibs/scte.
Command help
Walk heRFAmpOutputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SCTE-HMS-HE-RF-AMP-MIB' -M '/opt/observium/mibs/scte:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SCTE-HMS-HE-RF-AMP-MIB::heRFAmpOutputTable'
A table containing information about each RF Amp 
output used in an indoor environment.
heRFAmpOutputEntry row .1.3.6.1.4.1.5591.1.11.4.1.1.1.2.1
List of information about each RF Amp output.
Column Syntax OID
Index number corresponding to the RF Output.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5591.1.11.4.1.1.1.2.1.1
A description of the Amp output. The description text is
to be determined by the equipment manufacturer. For example,
Output A or Secondary Output.
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.5591.1.11.4.1.1.1.2.1.2
The output level of the RF amplifier output.
SCTE-HMS-HEADENDIDENT-MIBHeTenthdBmV .1.3.6.1.4.1.5591.1.11.4.1.1.1.2.1.3
This controls and reports the setting of an attenuator
in the amplifier RF chain.
SCTE-HMS-HEADENDIDENT-MIBHeTenthdBr/w .1.3.6.1.4.1.5591.1.11.4.1.1.1.2.1.4