SCHLEIFENBAUER-GENERIC-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
21
Rows
21
Columns
264
.1.3.6.1.4.1.44568.1.1.2.1
·
1 row entry
·
19 columns
Uses the schleifenbauer variant from
Command help
/opt/observium/mibs/schleifenbauer.
Walk deviceIdentificationTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SCHLEIFENBAUER-GENERIC-MIB' -M '/opt/observium/mibs/schleifenbauer:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SCHLEIFENBAUER-GENERIC-MIB::deviceIdentificationTable'
General identification parameters.
General identification parameters.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
A unique value for each PDU. Its value
ranges between 1 and the value of pduCount. |
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.44568.1.1.2.1.1.1 |
||||||
|
User configurable device name or identifier.
|
OctetStringr/w Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.2.1.1.2 |
||||||
|
User configurable device location identifier.
|
OctetStringr/w Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.2.1.1.3 |
||||||
|
Device category: 0 = Daisychain Module, 1 = Gateway Module, 2 = Controller Module (SF also uses -1 to meaning no module!)
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.44568.1.1.2.1.1.4 |
||||||
|
Product id
|
OctetString Constraints: range: 0-15 |
.1.3.6.1.4.1.44568.1.1.2.1.1.5 |
||||||
|
Firmware version number.
|
OctetString Constraints: range: 0-15 |
.1.3.6.1.4.1.44568.1.1.2.1.1.6 |
||||||
|
MAC address.
|
OctetString Constraints: range: 0-18 |
.1.3.6.1.4.1.44568.1.1.2.1.1.7 |
||||||
|
Date Of Manufacture (DOM)
|
OctetString Constraints: range: 0-15 |
.1.3.6.1.4.1.44568.1.1.2.1.1.8 |
||||||
|
Module serial number
|
OctetString Constraints: range: 0-15 |
.1.3.6.1.4.1.44568.1.1.2.1.1.9 |
||||||
|
Module part number.
|
OctetString Constraints: range: 0-15 |
.1.3.6.1.4.1.44568.1.1.2.1.1.10 |
||||||
|
Sales order number
|
OctetString Constraints: range: 0-15 |
.1.3.6.1.4.1.44568.1.1.2.1.1.11 |
||||||
|
Serial number
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.2.1.1.12 |
||||||
|
The device extra info
|
OctetStringr/w Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.2.1.1.13 |
||||||
|
The device state info as string
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.2.1.1.14 |
||||||
|
The device vendor name
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.2.1.1.15 |
||||||
|
The device unique identifier
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.2.1.1.16 |
||||||
|
The device IP Addr
|
SNMPv2-SMIIpAddress Type Constraints: range: 4 |
.1.3.6.1.4.1.44568.1.1.2.1.1.17 |
||||||
|
The device type. e.g. PDU, UPS, etc
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.2.1.1.18 |
||||||
|
The last error message
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.2.1.1.19 |
deviceConfigTable
table.1.3.6.1.4.1.44568.1.1.3.1
·
1 row entry
·
13 columns
Uses the schleifenbauer variant from
Command help
/opt/observium/mibs/schleifenbauer.
Walk deviceConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SCHLEIFENBAUER-GENERIC-MIB' -M '/opt/observium/mibs/schleifenbauer:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SCHLEIFENBAUER-GENERIC-MIB::deviceConfigTable'
A list to display device configuration.
A list to display device configuration.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
A unique value for each PDU. Its value
ranges between 1 and the value of pduCount. |
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.44568.1.1.3.1.1.1 |
||||
|
Maximum rated load of the device per phase (this value is also mentioned on the PDU profile), usually either 16A, 32A or 63A.
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.3.1.1.2 |
||||
|
Custom 64 character name field for the customer.
|
OctetStringr/w Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.3.1.1.3 |
||||
|
Formfactor of the device.
|
OctetString Constraints: range: 0-15 |
.1.3.6.1.4.1.44568.1.1.3.1.1.4 |
||||
|
Length of the device in millimeter.
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.3.1.1.5 |
||||
|
The number of branches available in the PDU, can be zero if no branches are available in the configuration.
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.3.1.1.6 |
||||
|
Number of measured outlets available in the PDU. If numbering of outlets used is non-contiguous: the highest outlet number is assumed as amount of measured outlets.
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.3.1.1.7 |
||||
|
Use neutral current measurements if available: 0 = No neutral current measurement, 1 = Use neutral current measurement.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.44568.1.1.3.1.1.8 |
||||
|
Total number of outlets available in the PDU, including hardwired outlets without a switchmeasure module.
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.3.1.1.9 |
||||
|
Total number of inputs: either zero (for no input metering), one or three for a single or three phase system.
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.3.1.1.10 |
||||
|
Total number of switched outlets available. If the numbering of outlets used is non-contiguous: the highest outlet number is assumed as amount of switched outlets.
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.3.1.1.11 |
||||
|
The number of total calculations available in the PDU, this is usually one but can be more.
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.3.1.1.12 |
||||
|
Voltage rating in V for this PDU.
|
OctetString Constraints: range: 0-15 |
.1.3.6.1.4.1.44568.1.1.3.1.1.13 |
deviceSettingsTable
table.1.3.6.1.4.1.44568.1.1.4.1
·
1 row entry
·
9 columns
Uses the schleifenbauer variant from
Command help
/opt/observium/mibs/schleifenbauer.
Walk deviceSettingsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SCHLEIFENBAUER-GENERIC-MIB' -M '/opt/observium/mibs/schleifenbauer:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SCHLEIFENBAUER-GENERIC-MIB::deviceSettingsTable'
device e.g. PDU settings.
device e.g. PDU configuration.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
A unique value for each PDU. Its value
ranges between 1 and the value of pduCount. |
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.44568.1.1.4.1.1.1 |
||||||||
|
Enable or disable current drop detection (0 = disabled, 1 = enabled)
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.44568.1.1.4.1.1.2 |
||||||||
|
Minimal delay between relay switch requests in milliseconds. The minimum delay is 100ms.
|
100SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.4.1.1.3 |
||||||||
|
Locate a unit. Set to '1' to switch on and to '0' to switch off this function.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.44568.1.1.4.1.1.4 |
||||||||
|
LED brightness setting for the light ring of a PDU
|
0.01%SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.4.1.1.5 |
||||||||
|
Setting this will disable all means of switching an outlet; only the powerup modes and delays will be respected (0 = disabled, 1 = enabled).
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.44568.1.1.4.1.1.6 |
||||||||
|
Behaviour of outlets on power-up. 0 = off, 1 = same state as at power down use default switch delay, 2 = same state, but delayed by individual delay timer, 3 = Outlets will always stay on (even at power down!)
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.44568.1.1.4.1.1.7 |
||||||||
|
Enables the sensor channel change detection. 0 = off (default), 1 = on
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.44568.1.1.4.1.1.8 |
||||||||
|
USB Mode. 0 = Disabled, 1 = Enabled
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.44568.1.1.4.1.1.9 |
deviceDaisychainTable
table.1.3.6.1.4.1.44568.1.1.5.1
·
1 row entry
·
5 columns
Uses the schleifenbauer variant from
Command help
/opt/observium/mibs/schleifenbauer.
Walk deviceDaisychainTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SCHLEIFENBAUER-GENERIC-MIB' -M '/opt/observium/mibs/schleifenbauer:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SCHLEIFENBAUER-GENERIC-MIB::deviceDaisychainTable'
device e.g. daisychain values.
device e.g. PDU configuration.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
A unique value for each PDU. Its value
ranges between 1 and the value of pduCount. |
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.44568.1.1.5.1.1.1 |
||||
|
Device index of the ring break location. Can be used to determine between which devices the ring is broken.
|
1SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.5.1.1.2 |
||||
|
SPBUS network architecture configuration. 0 = open ring network, 1 = closed ring network
|
1Enumeration Enumerated Values:
|
.1.3.6.1.4.1.44568.1.1.5.1.1.3 |
||||
|
Result of scan command, denotes the number of devices on the SPBUS network.
|
1SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.5.1.1.4 |
||||
|
List of unit addresses known to the device. Position ordered list of assigned unit addresses.
|
1OctetString Constraints: range: 0-255 |
.1.3.6.1.4.1.44568.1.1.5.1.1.5 |
deviceResetTable
table.1.3.6.1.4.1.44568.1.1.6.1
·
1 row entry
·
2 columns
Uses the schleifenbauer variant from
Command help
/opt/observium/mibs/schleifenbauer.
Walk deviceResetTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SCHLEIFENBAUER-GENERIC-MIB' -M '/opt/observium/mibs/schleifenbauer:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SCHLEIFENBAUER-GENERIC-MIB::deviceResetTable'
device e.g. PDU reset values.
device e.g. PDU configuration.
Indexes
| Column | Syntax | OID | ||
|---|---|---|---|---|
|
A unique value for each PDU. Its value
ranges between 1 and the value of pduCount. |
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.44568.1.1.6.1.1.1 |
||
|
Writing '1' to this register will invoke a warm restart of the device. Note that this will have no effect on outlet status!
|
1Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.44568.1.1.6.1.1.2 |
deviceInputsTable
table.1.3.6.1.4.1.44568.1.1.7.1
·
1 row entry
·
22 columns
Uses the schleifenbauer variant from
Command help
/opt/observium/mibs/schleifenbauer.
Walk deviceInputsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SCHLEIFENBAUER-GENERIC-MIB' -M '/opt/observium/mibs/schleifenbauer:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SCHLEIFENBAUER-GENERIC-MIB::deviceInputsTable'
A list to display status of Input.
A list to display status of Input.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
A unique value for each PDU. Its value
ranges between 1 and the value of pduCount. |
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.44568.1.1.7.1.1.1 |
|
Index of inputs.
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.44568.1.1.7.1.1.2 |
|
User configurable 64 character naming of the inputs or phases.
|
OctetStringr/w Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.7.1.1.3 |
|
Either the only phase in a single phase measurement; or one of the three phases in a multiphase measurement. This value is not resetable.
|
KWhSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.7.1.1.4 |
|
kWh subtotal register of the only phase in a single phase measurement; or one of three phases in a multiphase measurement.
|
KWhSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.7.1.1.5 |
|
Input power (in W) x100, MEASURED by the device using current, voltage, and power factor measurements of a phase.
|
0.01WSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.7.1.1.6 |
|
Input VA (volt-amps, in VA) 100x, MEASURED by the device using current and voltage measurements of a phase.
|
0.01VASNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.7.1.1.7 |
|
Reactive power (volt-amps reactive, in VAR) 100x, MEASURED by the device.
|
0.01VARSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.7.1.1.8 |
|
The effective power factor for each input 100x.
|
0.01%SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.7.1.1.9 |
|
Actual apparent, RMS current of an input 100x.
|
0.01ASNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.7.1.1.10 |
|
The actual voltage per input 100x.
|
0.01VSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.7.1.1.11 |
|
Frequency in Hz per input 100x.
|
0.01HzSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.7.1.1.12 |
|
The apparent accumulated energy VAh of each phase 100x.
|
5645VAhSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.7.1.1.13 |
|
The crest factor per input 100x. the ratio of peak values to the effective value.
|
0.01%SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.7.1.1.14 |
|
Input peak apparent 100x, RMS current; highest value since last reset of the peaks.
|
0.01ASNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.7.1.1.15 |
|
Maximum rated current in A per input.
|
1ASNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.7.1.1.16 |
|
Total harmonic distortion in percent per phase 100x.
|
0.01%SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.7.1.1.17 |
|
Type of input.
|
1SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.7.1.1.18 |
|
RMS voltage dip; lowest value since reset of dips.
|
0.01VSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.7.1.1.19 |
|
RMS voltage peak; highest value since reset of peaks.
|
0.01VSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.7.1.1.20 |
|
A mapping to which phase each input is connected to.
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.7.1.1.21 |
|
The input unbalanced. 100x.
|
0.01%SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.7.1.1.22 |
deviceOutletsTable
table.1.3.6.1.4.1.44568.1.1.8.1
·
1 row entry
·
23 columns
Uses the schleifenbauer variant from
Command help
/opt/observium/mibs/schleifenbauer.
Walk deviceOutletsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SCHLEIFENBAUER-GENERIC-MIB' -M '/opt/observium/mibs/schleifenbauer:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SCHLEIFENBAUER-GENERIC-MIB::deviceOutletsTable'
A list to display status of Outlet.
A list to display status of Outlet.
Indexes
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
A unique value for each PDU. Its value
ranges between 1 and the value of pduCount. |
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.44568.1.1.8.1.1.1 |
||||||||||||||||||||||||||||||||||||||||
|
An outlet index in pdu.
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.44568.1.1.8.1.1.2 |
||||||||||||||||||||||||||||||||||||||||
|
User configurable naming of individual outlets.
|
OctetStringr/w Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.8.1.1.3 |
||||||||||||||||||||||||||||||||||||||||
|
Total kWh of selected outlet. This value is not resetable.
|
KWhSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.8.1.1.4 |
||||||||||||||||||||||||||||||||||||||||
|
kWh subtotal register of selected output.
|
KWhSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.8.1.1.5 |
||||||||||||||||||||||||||||||||||||||||
|
Output power (in W), MEASURED by the device x100 using current, voltage, and power factor measurements of an outlet.
|
0.01WSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.8.1.1.6 |
||||||||||||||||||||||||||||||||||||||||
|
Output VA (volt-amps, in VA) 100x, MEASURED by the device using current and voltage measurements of an outlet.
|
0.01VASNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.8.1.1.7 |
||||||||||||||||||||||||||||||||||||||||
|
Reactive power (volt-amps reactive, in VAR) 100x, MEASURED by the device.
|
0.01VARSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.8.1.1.8 |
||||||||||||||||||||||||||||||||||||||||
|
Power factor x100 per outlet.
|
0.01%SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.8.1.1.9 |
||||||||||||||||||||||||||||||||||||||||
|
Actual apparent 100x, RMS current per outlet.
|
0.01ASNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.8.1.1.10 |
||||||||||||||||||||||||||||||||||||||||
|
Actual voltage on outlet 100x.
|
0.01VSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.8.1.1.11 |
||||||||||||||||||||||||||||||||||||||||
|
Outlet types: 0: Unknown, 1: BS, 2: C13, 3: C13 IEC Lock, 4: C19, 5: C19 IEC Lock, 6: CEE 16A 1 phase, 7: CEE 16A 3 phase, 8: CEE 32A 1 phase, 9: CEE 32A 3 phase, 10: CEE 63A 1 phase, 11: CEE 63A 3 phase, 12: COMBI IEC …
|
1Enumeration Enumerated Values:
|
.1.3.6.1.4.1.44568.1.1.8.1.1.12 |
||||||||||||||||||||||||||||||||||||||||
|
A mapping to which input each outlet is connected to.
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.8.1.1.13 |
||||||||||||||||||||||||||||||||||||||||
|
The state of the outlet relay(s).
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.44568.1.1.8.1.1.14 |
||||||||||||||||||||||||||||||||||||||||
|
The apparent accumulated energy VAh of each outlet 100x.
|
5645VAhSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.8.1.1.15 |
||||||||||||||||||||||||||||||||||||||||
|
The crest factor per outlet 100x. the ratio of peak values to the effective value.
|
0.01%SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.8.1.1.16 |
||||||||||||||||||||||||||||||||||||||||
|
Peak apparent 100x, RMS current of an outlet; highest value since last reset of the peaks.
|
0.01ASNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.8.1.1.17 |
||||||||||||||||||||||||||||||||||||||||
|
Outlet maximum rated current in A.
|
1ASNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.8.1.1.18 |
||||||||||||||||||||||||||||||||||||||||
|
Total harmonic distortion per outlet 100x.
|
0.01%SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.8.1.1.19 |
||||||||||||||||||||||||||||||||||||||||
|
Writing '1' will cause the outlet to power cycle.
|
1SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.8.1.1.20 |
||||||||||||||||||||||||||||||||||||||||
|
Outlet individual power cycle timer. This is the amount, in seconds.
|
1SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.8.1.1.21 |
||||||||||||||||||||||||||||||||||||||||
|
Delay before an individual outlet's relay switches on at power-up, in seconds.
|
1SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.8.1.1.22 |
||||||||||||||||||||||||||||||||||||||||
|
A mapping to which branch each outlet is connected to.
|
1SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.8.1.1.23 |
deviceBranchesTable
table.1.3.6.1.4.1.44568.1.1.9.1
·
1 row entry
·
22 columns
Uses the schleifenbauer variant from
Command help
/opt/observium/mibs/schleifenbauer.
Walk deviceBranchesTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SCHLEIFENBAUER-GENERIC-MIB' -M '/opt/observium/mibs/schleifenbauer:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SCHLEIFENBAUER-GENERIC-MIB::deviceBranchesTable'
A list to display status of Branch.
A list to display status of Outlet.
Indexes
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
A unique value for each PDU. Its value
ranges between 1 and the value of pduCount. |
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.44568.1.1.9.1.1.1 |
||||||||||||
|
A branch index in pdu.
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.44568.1.1.9.1.1.2 |
||||||||||||
|
User configurable naming of a branch in 64 characters per branch.
|
OctetStringr/w Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.9.1.1.3 |
||||||||||||
|
Branch energy total measurement in kWh. This value is not resetable. 24-bit little-endian integer.
|
KWhSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.9.1.1.4 |
||||||||||||
|
Branch energy subtotal measurement in kWh. Reset to zero with [rsbmks]. 24-bit little-endian integer.
|
KWhSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.9.1.1.5 |
||||||||||||
|
Branch power (in W) x100, MEASURED by the device using current, voltage, and power factor measurements of an branch.
|
0.01WSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.9.1.1.6 |
||||||||||||
|
Branch VA (volt-amps) 100x, MEASURED by the device using current and voltage measurements of an branch.
|
0.01VASNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.9.1.1.7 |
||||||||||||
|
Reactive power (volt-amps reactive, in VAR) of a branch x100, MEASURED by the device.
|
0.01VARSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.9.1.1.8 |
||||||||||||
|
The effective power factor per branch 100x.
|
0.01%SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.9.1.1.9 |
||||||||||||
|
Actual apparent 100x, RMS current of a branch.
|
0.01ASNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.9.1.1.10 |
||||||||||||
|
The actual voltage per branch x100.
|
0.01VSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.9.1.1.11 |
||||||||||||
|
Breaker type: 0: Unknown, 1: ETA (thermal, resettable), 2: HYMA (hydraulic magnetic), 3: MCB (thermal magnetic DIN), 4: MELT (small ceramic fuse), 5: REVOLVER (large ceramic fuse, DIN holder).
|
1Enumeration Enumerated Values:
|
.1.3.6.1.4.1.44568.1.1.9.1.1.12 |
||||||||||||
|
A mapping to which phase (input) each branch is connected to.
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.9.1.1.13 |
||||||||||||
|
Power state of the branch, usable for determining if a branch is currently tripped. 0 = OK, 1 = Tripped.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.44568.1.1.9.1.1.14 |
||||||||||||
|
The apparent accumulated energy VAh of each branch. 100x
|
5645VAhSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.9.1.1.15 |
||||||||||||
|
The crest factor per branch 100x. the ratio of peak values to the effective value.
|
0.01%SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.9.1.1.16 |
||||||||||||
|
Branch peak apparent 100x, RMS current; highest value since last reset of the peaks.
|
0.01ASNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.9.1.1.17 |
||||||||||||
|
Maximum rated current in A per branch (representing the breakerfuse value).
|
1ASNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.9.1.1.18 |
||||||||||||
|
Total harmonic distortion in percent per branch x100.
|
0.01%SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.9.1.1.19 |
||||||||||||
|
RMS voltage dip per branch; lowest value since reset of dips.
|
0.01VSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.9.1.1.20 |
||||||||||||
|
RMS voltage peak per branch; highest value since reset of peaks.
|
0.01VSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.9.1.1.21 |
||||||||||||
|
Frequency in Hz per branch 100x.
|
0.01HzSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.9.1.1.22 |
deviceTotalsTable
table.1.3.6.1.4.1.44568.1.1.10.1
·
1 row entry
·
16 columns
Uses the schleifenbauer variant from
Command help
/opt/observium/mibs/schleifenbauer.
Walk deviceTotalsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SCHLEIFENBAUER-GENERIC-MIB' -M '/opt/observium/mibs/schleifenbauer:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SCHLEIFENBAUER-GENERIC-MIB::deviceTotalsTable'
A list to display status of totals.
A list to display status of totals.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
A unique value for each PDU. Its value
ranges between 1 and the value of pduCount. |
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.44568.1.1.10.1.1.1 |
||||
|
A total index in pdu.
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.44568.1.1.10.1.1.2 |
||||
|
Total energy measurement in kWh. This value is not resetable.
|
KWhSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.10.1.1.3 |
||||
|
Totals power (in W) 100x, sum of phases.
|
0.01WSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.10.1.1.4 |
||||
|
Totals VA (volt-amps, in VA) 100x, sum of phases.
|
0.01VASNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.10.1.1.5 |
||||
|
Totals reactive power (volt-amps reactive, in VAR) 100x, sum of phases.
|
0.01VARSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.10.1.1.6 |
||||
|
System total actual apparent 100x, RMS current.
|
0.01ASNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.10.1.1.7 |
||||
|
The total apparent energy in VAh 100x. This value is not resetable.
|
5645VAhSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.10.1.1.8 |
||||
|
System total peak apparent 100x, RMS current; highest value since last reset of the peaks.
|
0.01ASNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.10.1.1.9 |
||||
|
Peak neutral current 100x.
|
0.01ASNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.10.1.1.10 |
||||
|
Neutral current measurement 100x. This is the sum of the neutral measurents channels: (only in three phase configs, one channel for all except 63A, then there will be two).
|
0.01ASNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.10.1.1.11 |
||||
|
Overvoltage protection module measurement (0 = OK, 1 = Overvoltage detected).
|
1Enumeration Enumerated Values:
|
.1.3.6.1.4.1.44568.1.1.10.1.1.12 |
||||
|
AC residual current measurement 100x.
|
0.01ASNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.10.1.1.13 |
||||
|
Peak residual current 100x.
|
0.01ASNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.10.1.1.14 |
||||
|
Residual current measurement 100x.
|
0.01ASNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.10.1.1.15 |
||||
|
DC residual current measurement 100x.
|
0.01ASNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.10.1.1.16 |
deviceSensorsTable
table.1.3.6.1.4.1.44568.1.1.11.1
·
1 row entry
·
9 columns
Uses the schleifenbauer variant from
Command help
/opt/observium/mibs/schleifenbauer.
Walk deviceSensorsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SCHLEIFENBAUER-GENERIC-MIB' -M '/opt/observium/mibs/schleifenbauer:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SCHLEIFENBAUER-GENERIC-MIB::deviceSensorsTable'
A list to display status of Sensors.
A list to display status of Sensor.
Indexes
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
A unique value for each PDU. Its value
ranges between 1 and the value of pduCount. |
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.44568.1.1.11.1.1.1 |
||||||||||
|
A port index in pdu.
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.44568.1.1.11.1.1.2 |
||||||||||
|
The sensor port name.
|
OctetStringr/w Constraints: range: 0-36 |
.1.3.6.1.4.1.44568.1.1.11.1.1.3 |
||||||||||
|
The sensor value 10x. E.g. a temperature of 25.7 C is passed as 257.
|
0.1SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.44568.1.1.11.1.1.4 |
||||||||||
|
The sensor type string.
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.11.1.1.5 |
||||||||||
|
Serial number of the sensor.
|
OctetString Constraints: range: 0-8 |
.1.3.6.1.4.1.44568.1.1.11.1.1.6 |
||||||||||
|
Source of the sensor.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.44568.1.1.11.1.1.7 |
||||||||||
|
State of the sensor.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.44568.1.1.11.1.1.8 |
||||||||||
|
Sensor measurement unit.
|
Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.11.1.1.9 |
deviceDigitalInputsTable
table.1.3.6.1.4.1.44568.1.1.40.1
·
1 row entry
·
7 columns
Uses the schleifenbauer variant from
Command help
/opt/observium/mibs/schleifenbauer.
Walk deviceDigitalInputsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SCHLEIFENBAUER-GENERIC-MIB' -M '/opt/observium/mibs/schleifenbauer:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SCHLEIFENBAUER-GENERIC-MIB::deviceDigitalInputsTable'
A list to display status of Digital Input.
A list to display status of Digital Input.
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
A unique value for each PDU. Its value
ranges between 1 and the value of pduCount. |
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.44568.1.1.40.1.1.1 |
||||||||||
|
A port index in pdu.
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.44568.1.1.40.1.1.2 |
||||||||||
|
The digital input name.
|
OctetStringr/w Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.40.1.1.3 |
||||||||||
|
Serial number of the digital input.
|
OctetString Constraints: range: 0-8 |
.1.3.6.1.4.1.44568.1.1.40.1.1.6 |
||||||||||
|
Source of the digital input.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.44568.1.1.40.1.1.7 |
||||||||||
|
State of the digital input.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.44568.1.1.40.1.1.8 |
||||||||||
|
The digital input state
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.44568.1.1.40.1.1.9 |
.1.3.6.1.4.1.44568.1.1.50.1
·
1 row entry
·
7 columns
Uses the schleifenbauer variant from
Command help
/opt/observium/mibs/schleifenbauer.
Walk deviceDigitalOutputsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SCHLEIFENBAUER-GENERIC-MIB' -M '/opt/observium/mibs/schleifenbauer:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SCHLEIFENBAUER-GENERIC-MIB::deviceDigitalOutputsTable'
A list to display status of Digital Output.
A list to display status of Digital Output.
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
A unique value for each PDU. Its value
ranges between 1 and the value of pduCount. |
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.44568.1.1.50.1.1.1 |
||||||||||
|
Digital Output index in pdu.
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.44568.1.1.50.1.1.2 |
||||||||||
|
The digital output port name.
|
OctetStringr/w Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.50.1.1.3 |
||||||||||
|
Serial number of the digital output.
|
OctetString Constraints: range: 0-8 |
.1.3.6.1.4.1.44568.1.1.50.1.1.6 |
||||||||||
|
Source of the digital output.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.44568.1.1.50.1.1.7 |
||||||||||
|
State of the digital output.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.44568.1.1.50.1.1.8 |
||||||||||
|
The digital outlet switch state.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.44568.1.1.50.1.1.9 |
dcStatusTable
table.1.3.6.1.4.1.44568.1.1.100.1
·
1 row entry
·
16 columns
Uses the schleifenbauer variant from
Command help
/opt/observium/mibs/schleifenbauer.
Walk dcStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SCHLEIFENBAUER-GENERIC-MIB' -M '/opt/observium/mibs/schleifenbauer:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SCHLEIFENBAUER-GENERIC-MIB::dcStatusTable'
A list to display status of Data center.
A list to display status of Data Center.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
A unique value for each PDU. Its value
ranges between 1 and the value of pduCount. |
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.44568.1.1.100.1.1.1 |
|
The datacenter name
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.100.1.1.2 |
|
The datacenter state .e.g normal, etc.
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.100.1.1.3 |
|
The data center KWhTotal.
|
KWhInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.100.1.1.4 |
|
The datacenter power Watt. 100x.
|
0.01WInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.100.1.1.5 |
|
The daracenter power VA. 100x.
|
0.01WInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.100.1.1.6 |
|
The data center current. 100x.
|
0.01AInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.100.1.1.7 |
|
The data center Voltage. 100x.
|
0.01VInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.100.1.1.8 |
|
The temperature. 10x.
|
0.1CInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.100.1.1.9 |
|
The humidity. 10x.
|
0.1%Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.100.1.1.10 |
|
The residual current in mA
|
Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.100.1.1.11 |
|
The residual current AC component in mA
|
Integer32 Constraints: range: 0-512 |
.1.3.6.1.4.1.44568.1.1.100.1.1.12 |
|
The residual current DC component in mA
|
Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.100.1.1.13 |
|
The data center L1current. 100x.
|
0.01AInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.100.1.1.14 |
|
The data center L2 current. 100x.
|
0.01AInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.100.1.1.15 |
|
The data center L3 current. 100x.
|
0.01AInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.100.1.1.16 |
roomStatusTable
table.1.3.6.1.4.1.44568.1.1.110.1
·
1 row entry
·
17 columns
Uses the schleifenbauer variant from
Command help
/opt/observium/mibs/schleifenbauer.
Walk roomStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SCHLEIFENBAUER-GENERIC-MIB' -M '/opt/observium/mibs/schleifenbauer:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SCHLEIFENBAUER-GENERIC-MIB::roomStatusTable'
A list to display status of rooms.
A list to display status of a room.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
A unique value for each PDU. Its value
ranges between 1 and the value of pduCount. |
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.44568.1.1.110.1.1.1 |
|
The room name
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.110.1.1.2 |
|
The room statee.g. normal, degraded
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.110.1.1.3 |
|
The datacenter name in which this room is
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.110.1.1.4 |
|
The room KWhTotal.
|
KWhInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.110.1.1.5 |
|
The room power Watt. 100x.
|
0.01WInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.110.1.1.6 |
|
The room power VA. 100x.
|
0.01WInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.110.1.1.7 |
|
The room current. 100x.
|
0.01AInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.110.1.1.8 |
|
The room Voltage. 100x.
|
0.01VInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.110.1.1.9 |
|
The temperature. 10x.
|
0.1CInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.110.1.1.10 |
|
The humidity. 10x.
|
0.1%Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.110.1.1.11 |
|
The residual current in mA
|
Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.110.1.1.12 |
|
The residual current AC component in mA
|
Integer32 Constraints: range: 0-512 |
.1.3.6.1.4.1.44568.1.1.110.1.1.13 |
|
The residual current DC component in mA
|
Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.110.1.1.14 |
|
The room L1current. 100x.
|
0.01AInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.110.1.1.15 |
|
The room L2 current. 100x.
|
0.01AInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.110.1.1.16 |
|
The room L3 current. 100x.
|
0.01AInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.110.1.1.17 |
aisleStatusTable
table.1.3.6.1.4.1.44568.1.1.120.1
·
1 row entry
·
18 columns
Uses the schleifenbauer variant from
Command help
/opt/observium/mibs/schleifenbauer.
Walk aisleStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SCHLEIFENBAUER-GENERIC-MIB' -M '/opt/observium/mibs/schleifenbauer:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SCHLEIFENBAUER-GENERIC-MIB::aisleStatusTable'
A list to display status of aisle.
A list to display status of an aisle.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
A unique value for each PDU. Its value
ranges between 1 and the value of pduCount. |
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.44568.1.1.120.1.1.1 |
|
The aisle name
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.120.1.1.2 |
|
The aisle statee.g. normal, degraded
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.120.1.1.3 |
|
The datacenter name in which this room is
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.120.1.1.4 |
|
The room name in which this aisle is
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.120.1.1.5 |
|
The aisle KWhTotal.
|
KWhInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.120.1.1.6 |
|
The aisle power Watt. 100x.
|
0.01WInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.120.1.1.7 |
|
The aisle power VA. 100x.
|
0.01WInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.120.1.1.8 |
|
The aisle current. 100x.
|
0.01AInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.120.1.1.9 |
|
The aisle Voltage. 100x.
|
0.01VInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.120.1.1.10 |
|
The aisle temperature. 10x.
|
0.1CInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.120.1.1.11 |
|
The aisle humidity. 10x.
|
0.1%Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.120.1.1.12 |
|
The residual current in mA
|
Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.120.1.1.13 |
|
The residual current AC component in mA
|
Integer32 Constraints: range: 0-512 |
.1.3.6.1.4.1.44568.1.1.120.1.1.14 |
|
The residual current DC component in mA
|
Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.120.1.1.15 |
|
The aisle L1current. 100x.
|
0.01AInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.120.1.1.16 |
|
The aisle L2 current. 100x.
|
0.01AInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.120.1.1.17 |
|
The aisle L3 current. 100x.
|
0.01AInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.120.1.1.18 |
rackStatusTable
table.1.3.6.1.4.1.44568.1.1.130.1
·
1 row entry
·
19 columns
Uses the schleifenbauer variant from
Command help
/opt/observium/mibs/schleifenbauer.
Walk rackStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SCHLEIFENBAUER-GENERIC-MIB' -M '/opt/observium/mibs/schleifenbauer:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SCHLEIFENBAUER-GENERIC-MIB::rackStatusTable'
A list to display status of rack.
A list to display status of an rack.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
A unique value for each PDU. Its value
ranges between 1 and the value of pduCount. |
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.44568.1.1.130.1.1.1 |
|
The rack name
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.130.1.1.2 |
|
The rack state.g. normal, degraded
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.130.1.1.3 |
|
The datacenter name in which this room is
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.130.1.1.4 |
|
The room name in which this aisle is
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.130.1.1.5 |
|
The room name in which this aisle is
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.130.1.1.6 |
|
The rack KWhTotal.
|
KWhInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.130.1.1.7 |
|
The rack power Watt. 100x.
|
0.01WInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.130.1.1.8 |
|
The rack power VA. 100x.
|
0.01WInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.130.1.1.9 |
|
The rack current. 100x.
|
0.01AInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.130.1.1.10 |
|
The rack Voltage. 100x.
|
0.01VInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.130.1.1.11 |
|
The rack temperature. 10x.
|
0.1CInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.130.1.1.12 |
|
The rack humidity. 10x.
|
0.1%Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.130.1.1.13 |
|
The residual current in mA
|
Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.130.1.1.14 |
|
The residual current AC component in mA
|
Integer32 Constraints: range: 0-512 |
.1.3.6.1.4.1.44568.1.1.130.1.1.15 |
|
The residual current DC component in mA
|
Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.130.1.1.16 |
|
The rack L1current. 100x.
|
0.01AInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.130.1.1.17 |
|
The rack L2 current. 100x.
|
0.01AInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.130.1.1.18 |
|
The rack L3 current. 100x.
|
0.01AInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.130.1.1.19 |
rackDeviceStatusTable
table.1.3.6.1.4.1.44568.1.1.140.1
·
1 row entry
·
21 columns
Uses the schleifenbauer variant from
Command help
/opt/observium/mibs/schleifenbauer.
Walk rackDeviceStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SCHLEIFENBAUER-GENERIC-MIB' -M '/opt/observium/mibs/schleifenbauer:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SCHLEIFENBAUER-GENERIC-MIB::rackDeviceStatusTable'
A list to display status of rackDevice.
A list to display status of a rackDevice.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
A unique value for each PDU. Its value
ranges between 1 and the value of pduCount. |
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.44568.1.1.140.1.1.1 |
||||||
|
The rack device name
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.140.1.1.2 |
||||||
|
The rackDevice state.g. normal, degraded
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.140.1.1.3 |
||||||
|
The datacenter name in which this rack Device is
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.140.1.1.4 |
||||||
|
The rackDevice in tha rack inroom name in which this aisle is
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.140.1.1.5 |
||||||
|
The rackDevice in tha rack inroom name in which this aisle is
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.140.1.1.6 |
||||||
|
The rackDevice in tha rack inroom name in which this aisle is
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.140.1.1.7 |
||||||
|
The aisle KWhTotal.
|
KWhInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.140.1.1.8 |
||||||
|
The aisle power Watt. 100x.
|
0.01WInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.140.1.1.9 |
||||||
|
The aisle power VA. 100x.
|
0.01WInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.140.1.1.10 |
||||||
|
The aisle current. 100x.
|
0.01AInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.140.1.1.11 |
||||||
|
The aisle Voltage. 100x.
|
0.01VInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.140.1.1.12 |
||||||
|
The aisle temperature. 10x.
|
0.1CInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.140.1.1.13 |
||||||
|
The aisle humidity. 10x.
|
0.1%Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.140.1.1.14 |
||||||
|
The port switch state.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.44568.1.1.140.1.1.15 |
||||||
|
The residual current in mA
|
Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.140.1.1.16 |
||||||
|
The residual current AC component in mA
|
Integer32 Constraints: range: 0-512 |
.1.3.6.1.4.1.44568.1.1.140.1.1.17 |
||||||
|
The residual current DC component in mA
|
Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.140.1.1.18 |
||||||
|
The rack device L1 current. 100x.
|
0.01AInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.140.1.1.19 |
||||||
|
The rack device L2 current. 100x.
|
0.01AInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.140.1.1.20 |
||||||
|
The rack device L3 current. 100x.
|
0.01AInteger32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.140.1.1.21 |
rackDeviceConfigTable
table.1.3.6.1.4.1.44568.1.1.141.1
·
1 row entry
·
2 columns
Uses the schleifenbauer variant from
Command help
/opt/observium/mibs/schleifenbauer.
Walk rackDeviceConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SCHLEIFENBAUER-GENERIC-MIB' -M '/opt/observium/mibs/schleifenbauer:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SCHLEIFENBAUER-GENERIC-MIB::rackDeviceConfigTable'
A list to change status of RackDevice switch.
A list to edit status of Switch.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
A unique value for each group.
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.44568.1.1.141.1.1.1 |
||||
|
The rack Device switch state.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.44568.1.1.141.1.1.2 |
currentUserStatusTable
table.1.3.6.1.4.1.44568.1.1.600.1
·
1 row entry
·
3 columns
Uses the schleifenbauer variant from
Command help
/opt/observium/mibs/schleifenbauer.
Walk currentUserStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SCHLEIFENBAUER-GENERIC-MIB' -M '/opt/observium/mibs/schleifenbauer:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SCHLEIFENBAUER-GENERIC-MIB::currentUserStatusTable'
A list to display of current logged in users.
A list to display status of Inlet.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
A unique value for each PDU. Its value
ranges between 1 and the value of pduCount. |
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.44568.1.1.600.1.1.1 |
|
The logged in user name.
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.600.1.1.2 |
|
The role of this user
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.600.1.1.3 |
warningsTable
table.1.3.6.1.4.1.44568.1.1.700.1
·
1 row entry
·
7 columns
Uses the schleifenbauer variant from
Command help
/opt/observium/mibs/schleifenbauer.
Walk warningsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SCHLEIFENBAUER-GENERIC-MIB' -M '/opt/observium/mibs/schleifenbauer:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SCHLEIFENBAUER-GENERIC-MIB::warningsTable'
A list to display of current warnings.
A list to display warnings.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
A unique value for each warning
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.44568.1.1.700.1.1.1 |
|
This is a group or sensor
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.700.1.1.2 |
|
This is the group or device name
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.700.1.1.3 |
|
This is i, o s for device.
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.700.1.1.4 |
|
This is zero based port index
|
Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.700.1.1.5 |
|
voltage, Current, etc.
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.700.1.1.6 |
|
The value exceeding warning limit. 100x
|
0.01Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.700.1.1.7 |
criticalsTable
table.1.3.6.1.4.1.44568.1.1.800.1
·
1 row entry
·
7 columns
Uses the schleifenbauer variant from
Command help
/opt/observium/mibs/schleifenbauer.
Walk criticalsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SCHLEIFENBAUER-GENERIC-MIB' -M '/opt/observium/mibs/schleifenbauer:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SCHLEIFENBAUER-GENERIC-MIB::criticalsTable'
A list to display of current criticals.
A list to display warnings.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
A unique value for each critical
|
Integer32 Constraints: range: 1-256 |
.1.3.6.1.4.1.44568.1.1.800.1.1.1 |
|
This is a group type or sensor
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.800.1.1.2 |
|
This is the group or device name
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.800.1.1.3 |
|
This is i, o s for device.
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.800.1.1.4 |
|
This is zero based port index
|
Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.800.1.1.5 |
|
voltage, Current, etc.
|
OctetString Constraints: range: 0-63 |
.1.3.6.1.4.1.44568.1.1.800.1.1.6 |
|
The value exceeding critical limit. 100x
|
0.01Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.44568.1.1.800.1.1.7 |