RMCU

        RMCU Rev2 Board
    

Imported Objects

OBJECT-TYPERFC-1212
TRAP-TYPERFC-1215
DisplayStringRFC1213-MIB
NOTIFICATION-TYPE, Gauge32, enterprises, MODULE-IDENTITYSNMPv2-SMI
TEXTUAL-CONVENTIONSNMPv2-TC

Type Definitions (1)

Name Base Type Values/Constraints
FixedDiv1000

Objects

duracomm .1.3.6.1.4.1.15116
rmcu-r2v3 .1.3.6.1.4.1.15116.3
product .1.3.6.1.4.1.15116.3.1
name
.1.3.6.1.4.1.15116.3.1.1
version
.1.3.6.1.4.1.15116.3.1.2
build-date
.1.3.6.1.4.1.15116.3.1.3
control .1.3.6.1.4.1.15116.3.2
analog1name
.1.3.6.1.4.1.15116.3.2.1
analog5val
.1.3.6.1.4.1.15116.3.2.10
analog6name
.1.3.6.1.4.1.15116.3.2.11
analog6val
.1.3.6.1.4.1.15116.3.2.12
analog1val
.1.3.6.1.4.1.15116.3.2.2
analog2name
.1.3.6.1.4.1.15116.3.2.3
digin1name
.1.3.6.1.4.1.15116.3.2.33
digin1val
.1.3.6.1.4.1.15116.3.2.34
digin2name
.1.3.6.1.4.1.15116.3.2.35
digin2val
.1.3.6.1.4.1.15116.3.2.36
digin3name
.1.3.6.1.4.1.15116.3.2.37
digin3val
.1.3.6.1.4.1.15116.3.2.38
digin4name
.1.3.6.1.4.1.15116.3.2.39
analog2val
.1.3.6.1.4.1.15116.3.2.4
digin4val
.1.3.6.1.4.1.15116.3.2.40
analog3name
.1.3.6.1.4.1.15116.3.2.5
analog3val
.1.3.6.1.4.1.15116.3.2.6
digout1name
.1.3.6.1.4.1.15116.3.2.65
digout1val .1.3.6.1.4.1.15116.3.2.66
digout2name
.1.3.6.1.4.1.15116.3.2.67
digout2val .1.3.6.1.4.1.15116.3.2.68
digout3name
.1.3.6.1.4.1.15116.3.2.69
analog4name
.1.3.6.1.4.1.15116.3.2.7
digout3val .1.3.6.1.4.1.15116.3.2.70
digout4name
.1.3.6.1.4.1.15116.3.2.71
digout4val .1.3.6.1.4.1.15116.3.2.72
analog4val
.1.3.6.1.4.1.15116.3.2.8
analog5name
.1.3.6.1.4.1.15116.3.2.9
temperature
.1.3.6.1.4.1.15116.3.2.97
acval
.1.3.6.1.4.1.15116.3.2.98
traps .1.3.6.1.4.1.15116.3.3
control-ints .1.3.6.1.4.1.15116.3.4
analog1val-int .1.3.6.1.4.1.15116.3.4.1
acval-int .1.3.6.1.4.1.15116.3.4.17
temperature-int .1.3.6.1.4.1.15116.3.4.18
analog2val-int .1.3.6.1.4.1.15116.3.4.2
analog3val-int .1.3.6.1.4.1.15116.3.4.3
analog4val-int .1.3.6.1.4.1.15116.3.4.4
analog5val-int .1.3.6.1.4.1.15116.3.4.5
analog6val-int .1.3.6.1.4.1.15116.3.4.6

Notifications/Traps

NameOIDDescription
trap-auth.1.3.6.1.4.1.15116.3.3.1
Trap caused by authorization failure
trap-analog-urecover1.1.3.6.1.4.1.15116.3.3.104
Trap caused by analog input #1 recovering from under alarm
trap-analog-urecover2.1.3.6.1.4.1.15116.3.3.105
Trap caused by analog input #2 recovering from under alarm
trap-analog-urecover3.1.3.6.1.4.1.15116.3.3.106
Trap caused by analog input #3 recovering from under alarm
trap-analog-urecover4.1.3.6.1.4.1.15116.3.3.107
Trap caused by analog input #4 recovering from under alarm
trap-analog-urecover5.1.3.6.1.4.1.15116.3.3.108
Trap caused by analog input #5 recovering from under alarm
trap-analog-urecover6.1.3.6.1.4.1.15116.3.3.109
Trap caused by analog input #6 recovering from under alarm
trap-analog-orecover1.1.3.6.1.4.1.15116.3.3.120
Trap caused by analog input #1 recovering from over alarm
trap-analog-orecover2.1.3.6.1.4.1.15116.3.3.121
Trap caused by analog input #2 recovering from over alarm
trap-analog-orecover3.1.3.6.1.4.1.15116.3.3.122
Trap caused by analog input #3 recovering from over alarm
trap-analog-orecover4.1.3.6.1.4.1.15116.3.3.123
Trap caused by analog input #4 recovering from over alarm
trap-analog-orecover5.1.3.6.1.4.1.15116.3.3.124
Trap caused by analog input #5 recovering from over alarm
trap-analog-orecover6.1.3.6.1.4.1.15116.3.3.125
Trap caused by analog input #6 recovering from over alarm
trap-temp-urecover.1.3.6.1.4.1.15116.3.3.136
Trap caused by temperature recovering from under threshold alarm
trap-temp-orecover.1.3.6.1.4.1.15116.3.3.137
Trap caused by temperature recovering from over threshold alarm
trap-ac-urecover.1.3.6.1.4.1.15116.3.3.138
Trap caused by AC recovering from under threshold alarm
trap-ac-orecover.1.3.6.1.4.1.15116.3.3.139
Trap caused by AC recovering from over threshold alarm
trap-analog-under1.1.3.6.1.4.1.15116.3.3.18
Trap caused by analog input #1 being under threshold
trap-analog-under2.1.3.6.1.4.1.15116.3.3.19
Trap caused by analog input #2 being under threshold
trap-analog-over1.1.3.6.1.4.1.15116.3.3.2
Trap caused by analog input #1 being over threshold
trap-analog-under3.1.3.6.1.4.1.15116.3.3.20
Trap caused by analog input #3 being under threshold
trap-analog-under4.1.3.6.1.4.1.15116.3.3.21
Trap caused by analog input #4 being under threshold
trap-analog-under5.1.3.6.1.4.1.15116.3.3.22
Trap caused by analog input #5 being under threshold
trap-analog-under6.1.3.6.1.4.1.15116.3.3.23
Trap caused by analog input #6 being under threshold
trap-analog-over2.1.3.6.1.4.1.15116.3.3.3
Trap caused by analog input #2 being over threshold
trap-poweron.1.3.6.1.4.1.15116.3.3.34
Trap caused by power-on
trap-temp-over.1.3.6.1.4.1.15116.3.3.35
Trap caused by temperature being over threshold
trap-dig-close1.1.3.6.1.4.1.15116.3.3.36
Trap caused by digital input #1 closed
trap-dig-close2.1.3.6.1.4.1.15116.3.3.37
Trap caused by digital input #2 closed
trap-dig-close3.1.3.6.1.4.1.15116.3.3.38
Trap caused by digital input #3 closed
trap-dig-close4.1.3.6.1.4.1.15116.3.3.39
Trap caused by digital input #4 closed
trap-analog-over3.1.3.6.1.4.1.15116.3.3.4
Trap caused by analog input #3 being over threshold
trap-analog-over4.1.3.6.1.4.1.15116.3.3.5
Trap caused by analog input #4 being over threshold
trap-test.1.3.6.1.4.1.15116.3.3.52
Trap caused by user test
trap-dig-open1.1.3.6.1.4.1.15116.3.3.53
Trap caused by digital input #1 open
trap-dig-open2.1.3.6.1.4.1.15116.3.3.54
Trap caused by digital input #2 open
trap-dig-open3.1.3.6.1.4.1.15116.3.3.55
Trap caused by digital input #3 open
trap-dig-open4.1.3.6.1.4.1.15116.3.3.56
Trap caused by digital input #4 open
trap-analog-over5.1.3.6.1.4.1.15116.3.3.6
Trap caused by analog input #5 being over threshold
trap-ac-under.1.3.6.1.4.1.15116.3.3.69
Trap caused by AC under threshold
trap-analog-over6.1.3.6.1.4.1.15116.3.3.7
Trap caused by analog input #6 being over threshold
trap-ac-over.1.3.6.1.4.1.15116.3.3.70
Trap caused by AC over threshold
trap-temp-under.1.3.6.1.4.1.15116.3.3.71
Trap caused by temperature being under threshold
trap-digout-inactive1.1.3.6.1.4.1.15116.3.3.72
Trap caused by digitout output #1 going inactive
trap-digout-inactive2.1.3.6.1.4.1.15116.3.3.73
Trap caused by digitout output #2 going inactive
trap-digout-inactive3.1.3.6.1.4.1.15116.3.3.74
Trap caused by digitout output #3 going inactive
trap-digout-inactive4.1.3.6.1.4.1.15116.3.3.75
Trap caused by digitout output #4 going inactive
trap-digout-active1.1.3.6.1.4.1.15116.3.3.88
Trap caused by digitout output #1 going active
trap-digout-active2.1.3.6.1.4.1.15116.3.3.89
Trap caused by digitout output #2 going active
trap-digout-active3.1.3.6.1.4.1.15116.3.3.90
Trap caused by digitout output #3 going active
trap-digout-active4.1.3.6.1.4.1.15116.3.3.91
Trap caused by digitout output #4 going active