READYNAS-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
5
Rows
5
Columns
20

diskTable

table mandatory
.1.3.6.1.4.1.4526.18.3 · 1 row entry · 5 columns
Uses the netgear variant from /opt/observium/mibs/netgear.
Command help
Walk diskTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'READYNAS-MIB' -M '/opt/observium/mibs/netgear:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'READYNAS-MIB::diskTable'
A table of physical disks attached to the NAS device.
diskEntry row .1.3.6.1.4.1.4526.18.3.1
An entry in the physical disk table.
Indexes
Column Syntax OID
diskNumbermandatory
Instance number of the disk entry.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4526.18.3.1.1
diskChannelmandatory
Channel number that the disk is connected to.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4526.18.3.1.2
diskModelmandatory
The disk drive's model name.
RFC1213-MIBDisplayString .1.3.6.1.4.1.4526.18.3.1.3
diskStatemandatory
The current state of the Disk.
Possible states:
0: Online
1: Offline
RFC1213-MIBDisplayString .1.3.6.1.4.1.4526.18.3.1.4
temperature of this disk.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4526.18.3.1.5

fanTable

table mandatory
.1.3.6.1.4.1.4526.18.4 · 1 row entry · 3 columns
Uses the netgear variant from /opt/observium/mibs/netgear.
Command help
Walk fanTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'READYNAS-MIB' -M '/opt/observium/mibs/netgear:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'READYNAS-MIB::fanTable'
fanEntry row .1.3.6.1.4.1.4526.18.4.1
Indexes
Column Syntax OID
fanNumbermandatory
Instance number of this fan entry.
Integer32
Constraints:
range: 1-10000000
.1.3.6.1.4.1.4526.18.4.1.1
fanRPMmandatory
The current speed of the fan.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4526.18.4.1.2
fanTypemandatory
What fan is used for:
SYS: for system board
CPU: for CPU
CAS: for system case
RFC1213-MIBDisplayString .1.3.6.1.4.1.4526.18.4.1.3

temperatureTable

table mandatory
.1.3.6.1.4.1.4526.18.5 · 1 row entry · 3 columns
Uses the netgear variant from /opt/observium/mibs/netgear.
Command help
Walk temperatureTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'READYNAS-MIB' -M '/opt/observium/mibs/netgear:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'READYNAS-MIB::temperatureTable'
temperatureEntry row .1.3.6.1.4.1.4526.18.5.1
Column Syntax OID
Instance number of this temperature probe entry.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4526.18.5.1.1
The current temperature of this probe.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4526.18.5.1.2
The current temperature status.
RFC1213-MIBDisplayString .1.3.6.1.4.1.4526.18.5.1.3

volumeTable

table mandatory
.1.3.6.1.4.1.4526.18.7 · 1 row entry · 6 columns
Uses the netgear variant from /opt/observium/mibs/netgear.
Command help
Walk volumeTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'READYNAS-MIB' -M '/opt/observium/mibs/netgear:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'READYNAS-MIB::volumeTable'
A table of active volumes on the NAS device.
volumeEntry row .1.3.6.1.4.1.4526.18.7.1
An entry in the volume table.
Indexes
Column Syntax OID
volumeNumbermandatory
Instance number of the volume entry.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4526.18.7.1.1
volumeNamemandatory
The name of the volume.
RFC1213-MIBDisplayString .1.3.6.1.4.1.4526.18.7.1.2
The RAID level of the volume.
RFC1213-MIBDisplayString .1.3.6.1.4.1.4526.18.7.1.3
volumeStatusmandatory
The severity of the volume.
Possible values:
1: Clean
2: Error
16: Initialized (Normal)
RFC1213-MIBDisplayString .1.3.6.1.4.1.4526.18.7.1.4
volumeSizemandatory
The size of the volume in megabytes.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4526.18.7.1.5
Free space on the volume in megabytes.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4526.18.7.1.6

psuTable

table mandatory
.1.3.6.1.4.1.4526.18.8 · 1 row entry · 3 columns
Uses the netgear variant from /opt/observium/mibs/netgear.
Command help
Walk psuTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'READYNAS-MIB' -M '/opt/observium/mibs/netgear:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'READYNAS-MIB::psuTable'
psuEntry row .1.3.6.1.4.1.4526.18.8.1
Indexes
Column Syntax OID
psuNumbermandatory
Instance number of this power supply unit.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4526.18.8.1.1
psuDescmandatory
The description of this PSU.
RFC1213-MIBDisplayString .1.3.6.1.4.1.4526.18.8.1.2
psuStatusmandatory
The current PSU status.
RFC1213-MIBDisplayString .1.3.6.1.4.1.4526.18.8.1.3