READYNAS-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
5
Rows
5
Columns
20
.1.3.6.1.4.1.4526.18.3
·
1 row entry
·
5 columns
Uses the netgear variant from
Command help
/opt/observium/mibs/netgear.
Walk diskTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'READYNAS-MIB' -M '/opt/observium/mibs/netgear:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'READYNAS-MIB::diskTable'
A table of physical disks attached to the NAS device.
An entry in the physical disk table.
Indexes
| Column | Syntax | OID |
|---|---|---|
diskNumbermandatory Instance number of the disk entry. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.4526.18.3.1.1 |
diskChannelmandatory Channel number that the disk is connected to. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.4526.18.3.1.2 |
diskModelmandatory The disk drive's model name. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.4526.18.3.1.3 |
diskStatemandatory The current state of the Disk.Possible states: 0: Online 1: Offline | RFC1213-MIBDisplayString | .1.3.6.1.4.1.4526.18.3.1.4 |
diskTemperaturemandatory temperature of this disk. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.4526.18.3.1.5 |
.1.3.6.1.4.1.4526.18.4
·
1 row entry
·
3 columns
Uses the netgear variant from
Command help
/opt/observium/mibs/netgear.
Walk fanTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'READYNAS-MIB' -M '/opt/observium/mibs/netgear:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'READYNAS-MIB::fanTable'
| Column | Syntax | OID |
|---|---|---|
fanNumbermandatory Instance number of this fan entry. | Integer32 Constraints: range: 1-10000000 | .1.3.6.1.4.1.4526.18.4.1.1 |
fanRPMmandatory The current speed of the fan. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.4526.18.4.1.2 |
fanTypemandatory What fan is used for:SYS: for system board CPU: for CPU CAS: for system case | RFC1213-MIBDisplayString | .1.3.6.1.4.1.4526.18.4.1.3 |
.1.3.6.1.4.1.4526.18.5
·
1 row entry
·
3 columns
Uses the netgear variant from
Command help
/opt/observium/mibs/netgear.
Walk temperatureTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'READYNAS-MIB' -M '/opt/observium/mibs/netgear:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'READYNAS-MIB::temperatureTable'
Indexes
| Column | Syntax | OID |
|---|---|---|
temperatureNumbermandatory Instance number of this temperature probe entry. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.4526.18.5.1.1 |
temperatureValuemandatory The current temperature of this probe. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.4526.18.5.1.2 |
temperatureStatusmandatory The current temperature status. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.4526.18.5.1.3 |
.1.3.6.1.4.1.4526.18.7
·
1 row entry
·
6 columns
Uses the netgear variant from
Command help
/opt/observium/mibs/netgear.
Walk volumeTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'READYNAS-MIB' -M '/opt/observium/mibs/netgear:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'READYNAS-MIB::volumeTable'
A table of active volumes on the NAS device.
An entry in the volume table.
Indexes
| Column | Syntax | OID |
|---|---|---|
volumeNumbermandatory Instance number of the volume entry. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.4526.18.7.1.1 |
volumeNamemandatory The name of the volume. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.4526.18.7.1.2 |
volumeRAIDLevelmandatory The RAID level of the volume. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.4526.18.7.1.3 |
volumeStatusmandatory The severity of the volume.Possible values: 1: Clean 2: Error 16: Initialized (Normal) | RFC1213-MIBDisplayString | .1.3.6.1.4.1.4526.18.7.1.4 |
volumeSizemandatory The size of the volume in megabytes. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.4526.18.7.1.5 |
volumeFreeSpacemandatory Free space on the volume in megabytes. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.4526.18.7.1.6 |
.1.3.6.1.4.1.4526.18.8
·
1 row entry
·
3 columns
Uses the netgear variant from
Command help
/opt/observium/mibs/netgear.
Walk psuTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'READYNAS-MIB' -M '/opt/observium/mibs/netgear:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'READYNAS-MIB::psuTable'
| Column | Syntax | OID |
|---|---|---|
psuNumbermandatory Instance number of this power supply unit. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.4526.18.8.1.1 |
psuDescmandatory The description of this PSU. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.4526.18.8.1.2 |
psuStatusmandatory The current PSU status. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.4526.18.8.1.3 |