RBN-SYS-RESOURCES-MIB

The management information definitions for the
system resources management of a Redback network
device.  This MIB is viewable under all contexts.
    

Imported Objects

IANAItuProbableCause, IANAItuEventTypeIANA-ITU-ALARM-TC-MIB
ItuPerceivedSeverityITU-ALARM-TC-MIB
rbnMgmtRBN-SMI
RbnSlot, RbnPercentage, RbnKBytesRBN-TC
SnmpAdminStringSNMP-FRAMEWORK-MIB
OBJECT-GROUP, NOTIFICATION-GROUP, MODULE-COMPLIANCESNMPv2-CONF
MODULE-IDENTITY, Counter32, TimeTicks, Integer32, Unsigned32, OBJECT-TYPE, NOTIFICATION-TYPESNMPv2-SMI
DateAndTime, TruthValueSNMPv2-TC

Objects

rbnSysResourcesMib .1.3.6.1.4.1.2352.2.24
rbnSRMIBNotifications .1.3.6.1.4.1.2352.2.24.0
rbnSRMIBObjects .1.3.6.1.4.1.2352.2.24.1
rbnSRProcess .1.3.6.1.4.1.2352.2.24.1.1
rbnSRProcessNotifyLastUpdate
.1.3.6.1.4.1.2352.2.24.1.1.1
rbnSRProcessEventNotifyEnable .1.3.6.1.4.1.2352.2.24.1.1.2
rbnSRProcessNotifyTable .1.3.6.1.4.1.2352.2.24.1.1.3
rbnSRProcessNotifyEntry .1.3.6.1.4.1.2352.2.24.1.1.3.1
rbnSRProcessNotifyProcName .1.3.6.1.4.1.2352.2.24.1.1.3.1.1
rbnSRProcessNotifyPID .1.3.6.1.4.1.2352.2.24.1.1.3.1.2
rbnSRProcessNotifyEventCause .1.3.6.1.4.1.2352.2.24.1.1.3.1.3
rbnSRProcessNotifyEventType .1.3.6.1.4.1.2352.2.24.1.1.3.1.4
rbnSRProcessNumOfSpawn .1.3.6.1.4.1.2352.2.24.1.1.3.1.5
rbnSRProcessNotifyLastTimeSent
.1.3.6.1.4.1.2352.2.24.1.1.3.1.6
rbnIssuObjects .1.3.6.1.4.1.2352.2.24.1.10
rbnIssuState .1.3.6.1.4.1.2352.2.24.1.10.1
rbnChassisGroup .1.3.6.1.4.1.2352.2.24.1.11
rbnChassisAlarmId .1.3.6.1.4.1.2352.2.24.1.11.1
rbnChassisAlarmType
.1.3.6.1.4.1.2352.2.24.1.11.2
rbnChassisAlarmDateAndTime
.1.3.6.1.4.1.2352.2.24.1.11.3
rbnChassisAlarmDescription .1.3.6.1.4.1.2352.2.24.1.11.4
rbnChassisAlarmProbableCause
.1.3.6.1.4.1.2352.2.24.1.11.5
rbnChassisAlarmSeverity
.1.3.6.1.4.1.2352.2.24.1.11.6
rbnSRStorage .1.3.6.1.4.1.2352.2.24.1.2
rbnSRStorageTable .1.3.6.1.4.1.2352.2.24.1.2.1
rbnSRStorageEntry .1.3.6.1.4.1.2352.2.24.1.2.1.1
rbnSRStorageIndex .1.3.6.1.4.1.2352.2.24.1.2.1.1.1
rbnSRStorageErrors
.1.3.6.1.4.1.2352.2.24.1.2.1.1.10
rbnSRStorageDescr .1.3.6.1.4.1.2352.2.24.1.2.1.1.2
rbnSRStorageMedia .1.3.6.1.4.1.2352.2.24.1.2.1.1.3
rbnSRStorageRemovable
.1.3.6.1.4.1.2352.2.24.1.2.1.1.4
rbnSRStorageSize
.1.3.6.1.4.1.2352.2.24.1.2.1.1.5
rbnSRStorageUtilization
.1.3.6.1.4.1.2352.2.24.1.2.1.1.6
rbnSRStorageSlot
.1.3.6.1.4.1.2352.2.24.1.2.1.1.7
rbnSRStorageMountTime
.1.3.6.1.4.1.2352.2.24.1.2.1.1.8
rbnSRStorageStatus .1.3.6.1.4.1.2352.2.24.1.2.1.1.9
rbnSseDiskStorageTable .1.3.6.1.4.1.2352.2.24.1.2.2
rbnSseDiskStorageEntry .1.3.6.1.4.1.2352.2.24.1.2.2.1
rbnSseDiskSlot
.1.3.6.1.4.1.2352.2.24.1.2.2.1.1
rbnSseDiskNum .1.3.6.1.4.1.2352.2.24.1.2.2.1.2
rbnSseDiskState .1.3.6.1.4.1.2352.2.24.1.2.2.1.3
rbnSseDiskSize .1.3.6.1.4.1.2352.2.24.1.2.2.1.4
rbnSseDiskUsed .1.3.6.1.4.1.2352.2.24.1.2.2.1.5
rbnSRSystem .1.3.6.1.4.1.2352.2.24.1.3
rbnSRSystemUptime
.1.3.6.1.4.1.2352.2.24.1.3.1
rbnSRSystemDate
.1.3.6.1.4.1.2352.2.24.1.3.2
rbnPowerExceeded .1.3.6.1.4.1.2352.2.24.1.4
rbnSRPowerExceededStatus .1.3.6.1.4.1.2352.2.24.1.4.1
rbnSseDiskAlarmDateAndTime
.1.3.6.1.4.1.2352.2.24.1.5
rbnSseDiskAlarmSeverity
.1.3.6.1.4.1.2352.2.24.1.6
rbnSseDiskAlarmProbableCause
.1.3.6.1.4.1.2352.2.24.1.7
rbnSseDiskEventType
.1.3.6.1.4.1.2352.2.24.1.8
rbnSseDiskAlarmDescription .1.3.6.1.4.1.2352.2.24.1.9
rbnSRMIBConformance .1.3.6.1.4.1.2352.2.24.2
rbnSRMIBCompliances .1.3.6.1.4.1.2352.2.24.2.1
rbnSRMIBGroups .1.3.6.1.4.1.2352.2.24.2.2

Notifications/Traps

NameOIDDescription
rbnSRProcessEvent




.1.3.6.1.4.1.2352.2.24.0.1
ication is sent each time the agent is informed of
a process death/birth event.
rbnSseDiskVoltageFailureAlarm






.1.3.6.1.4.1.2352.2.24.0.10
skVoltageFailureAlarm notification signifies that the
hard disk voltage has failed.
rbnSseDiskOverHeatAlarm






.1.3.6.1.4.1.2352.2.24.0.11
skOverHeatAlarm notification signifies that the
hard disk overheating.
rbnSseDiskReadFailureAlarm






.1.3.6.1.4.1.2352.2.24.0.12
skReadFailureAlarm notification signifies that the
hard disk read failure.
rbnIssuStateChange

.1.3.6.1.4.1.2352.2.24.0.13
tion reporting a change in ISSU state. The new
state is returned in the notification.
rbnChassisAlarm






.1.3.6.1.4.1.2352.2.24.0.14
isAlarm notification signifies that
an alarm has been raised/cleared on the chassis.
rbnSRSwitchoverEvent.1.3.6.1.4.1.2352.2.24.0.2
ication identifies when a switchover
occurs from one main processor module to a backup.
rbnSRStorageFailedEvent



.1.3.6.1.4.1.2352.2.24.0.3
ication is sent when the value of
rbnSRStorageStatus for a device changes to 'failed'.
rbnSRPowerExceededEvent

.1.3.6.1.4.1.2352.2.24.0.4
ication identifies when a controller card
is inserted and results in more power being drawn
than recommended.
rbnSseDiskHealthDegradedAlarm






.1.3.6.1.4.1.2352.2.24.0.5
skHealthDegradedAlarm notification signifies that the
hard disk health has degraded.
rbnSseDiskFailedAlarm






.1.3.6.1.4.1.2352.2.24.0.6
skFailedAlarm notification signifies that the
hard disk has failed.
rbnSseDiskMissingAlarm






.1.3.6.1.4.1.2352.2.24.0.7
skMissingAlarm notification signifies that the
hard disk is missing.
rbnSseDiskUnsupportedAlarm






.1.3.6.1.4.1.2352.2.24.0.8
skUnsupportedAlarm notification signifies that the
hard disk is not supported.
rbnSseDiskOOSAlarm






.1.3.6.1.4.1.2352.2.24.0.9
skOOSAlarm notification signifies that the
hard disk is out of service.