RBN-ENVMON-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
6
Rows
6
Columns
21
.1.3.6.1.4.1.2352.2.4.1.1 · 1 row entry · 4 columns
Uses the ericsson variant from /opt/observium/mibs/ericsson.
Command help
Walk rbnFanStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'RBN-ENVMON-MIB' -M '/opt/observium/mibs/ericsson:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RBN-ENVMON-MIB::rbnFanStatusTable'
This table contains one row per fan test point.
Note that there is not necessarily a one-to-one
relationship between fan test points and fan
assemblies; a single test point may be used to
monitor the status of multiple fans.
rbnFanStatusEntry row .1.3.6.1.4.1.2352.2.4.1.1.1
Information about a particular fan test point
Indexes
Column Syntax OID
The index of a fan test point.
Integer32
Constraints:
range: 1-2147483647
.1.3.6.1.4.1.2352.2.4.1.1.1.1
The description of a fan test point. If an instance of
this object is associated with a single fan assembly,
then the value of this object should be the same as the
name by which the assembly is normally referenced. I…
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.2352.2.4.1.1.1.2
rbnFanFaildeprecated
The status of a fan test point. If an instance of
this object has the value true, then a fan monitored
by the test point has failed. If an instance of
this object has the value false, then the fan (or fans)
monitored …
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.2352.2.4.1.1.1.3
The status of a fan test point. If an instance of
this object has the value normal, then the fan (or
fans) monitored by the test point is operational. If
an instance of this object has the value failed, then
the fan…
Enumeration
Enumerated Values:
1normal
2failed
3absent
4unknown
.1.3.6.1.4.1.2352.2.4.1.1.1.4
.1.3.6.1.4.1.2352.2.4.1.2 · 1 row entry · 4 columns
Uses the ericsson variant from /opt/observium/mibs/ericsson.
Command help
Walk rbnPowerStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'RBN-ENVMON-MIB' -M '/opt/observium/mibs/ericsson:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RBN-ENVMON-MIB::rbnPowerStatusTable'
This table contains one row per power test point.
Note that there is not necessarily a one-to-one
relationship between power test points and power
supply assemblies; a single test point may be used
to monitor the status of multiple power supplies.
rbnPowerStatusEntry row .1.3.6.1.4.1.2352.2.4.1.2.1
Information about a particular power test point
Indexes
Column Syntax OID
The index of a power test point.
Integer32
Constraints:
range: 1-2147483647
.1.3.6.1.4.1.2352.2.4.1.2.1.1
The description of a power supply test point. If an
instance of this object is associated with a single
power supply assembly, then the value of this object
should be the same as the name by which the assembly
is norma…
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.2352.2.4.1.2.1.2
rbnPowerFaildeprecated
The status of a power test point. If an instance of
this object has the value true, then a power supply
monitored by the test point has failed. If an instance
of this object has the value false, then the power
supply …
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.2352.2.4.1.2.1.3
The status of a power test point. If an instance of
this object has the value normal, then the power
supply (or supplies) monitored by the test point is
operational. If an instance of this object has the
value fail…
Enumeration
Enumerated Values:
1normal
2failed
3absent
4unknown
.1.3.6.1.4.1.2352.2.4.1.2.1.4
.1.3.6.1.4.1.2352.2.4.1.3 · 1 row entry · 4 columns
Uses the ericsson variant from /opt/observium/mibs/ericsson.
Command help
Walk rbnVoltageSensorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'RBN-ENVMON-MIB' -M '/opt/observium/mibs/ericsson:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RBN-ENVMON-MIB::rbnVoltageSensorTable'
This table contains one row per voltage test point.
Each physical entity (e.g. cards) in the system may
contain zero or more voltage test points.
rbnVoltageSensorEntry row .1.3.6.1.4.1.2352.2.4.1.3.1
Information about a particular voltage test point.
Column Syntax OID
An arbitrary value which uniquely identifies a
voltage test point on a particular physical entity.
Index values for different test points are not
necessarily contiguous.
Integer32
Constraints:
range: 1-2147483647
.1.3.6.1.4.1.2352.2.4.1.3.1.1
The description of a voltage test point. Typically
an instance of this object will hold a user-friendly
description of the physical entity and the level of
voltage being monitored by this test point.
OctetString
Constraints:
range: 0-48
.1.3.6.1.4.1.2352.2.4.1.3.1.2
The desired voltage level for this test point. If
the monitored voltage level (rbnVoltageCurrent) is
equal to this value, then the system is performing
as designed.
millivoltsRbnVoltage
Type Constraints:
range: 0..50000
.1.3.6.1.4.1.2352.2.4.1.3.1.3
The current voltage level at this test point.
millivoltsRbnVoltage
Type Constraints:
range: 0..50000
.1.3.6.1.4.1.2352.2.4.1.3.1.4

rbnCpuTempSensorTable

table deprecated
.1.3.6.1.4.1.2352.2.4.1.4 · 1 row entry · 3 columns
Uses the ericsson variant from /opt/observium/mibs/ericsson.
Command help
Walk rbnCpuTempSensorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'RBN-ENVMON-MIB' -M '/opt/observium/mibs/ericsson:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RBN-ENVMON-MIB::rbnCpuTempSensorTable'
This table contains one row per CPU temperature
sensor. Each physical entity in the system may have
zero or more CPUs. Each of those CPUs that has a
temperature sensor will show up here.
rbnCpuTempSensorEntry row .1.3.6.1.4.1.2352.2.4.1.4.1
Information about a particular CPU temperature test
point.
Column Syntax OID
rbnCpuTempIndexdeprecated
An arbitrary value which uniquely identifies a CPU on
a particular physical entity. Index values for
different CPUs are not necessarily contiguous.
Integer32
Constraints:
range: 1-2147483647
.1.3.6.1.4.1.2352.2.4.1.4.1.1
rbnCpuTempDescrdeprecated
The description of a CPU temperature test
point. Typically an instance of this object will hold
a user-friendly description of the physical entity
and a description of the CPU being monitored by this
test point.
OctetString
Constraints:
range: 0-48
.1.3.6.1.4.1.2352.2.4.1.4.1.2
The current temperature of this CPU.
degreesRbnTemperature
Type Constraints:
range: 0..100
.1.3.6.1.4.1.2352.2.4.1.4.1.3
.1.3.6.1.4.1.2352.2.4.1.5 · 1 row entry · 3 columns
Uses the ericsson variant from /opt/observium/mibs/ericsson.
Command help
Walk rbnFanSpeedTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'RBN-ENVMON-MIB' -M '/opt/observium/mibs/ericsson:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RBN-ENVMON-MIB::rbnFanSpeedTable'
This table contains one row per fan unit within a fan
test point.
rbnFanSpeedEntry row .1.3.6.1.4.1.2352.2.4.1.5.1
Information about a particular fan unit within a fan
test point.
Column Syntax OID
This is the fan identification number that describes the
specific location of the fan unit within a fan test point.
Integer32
Constraints:
range: 1-2147483647
.1.3.6.1.4.1.2352.2.4.1.5.1.1
The description of the fan unit within a fan test point.
OctetString
Constraints:
range: 0-32
.1.3.6.1.4.1.2352.2.4.1.5.1.2
The current speed of this fan unit.
RbnFanSpeed .1.3.6.1.4.1.2352.2.4.1.5.1.3
.1.3.6.1.4.1.2352.2.4.1.6 · 1 row entry · 3 columns
Uses the ericsson variant from /opt/observium/mibs/ericsson.
Command help
Walk rbnEntityTempSensorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'RBN-ENVMON-MIB' -M '/opt/observium/mibs/ericsson:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RBN-ENVMON-MIB::rbnEntityTempSensorTable'
This table contains one row per temperature
sensor on the physical entity.
rbnEntityTempSensorEntry row .1.3.6.1.4.1.2352.2.4.1.6.1
Information about a particular temperature test
point.
Column Syntax OID
An arbitrary value which uniquely identifies a
particular physical entity. Index values are
not necessarily contiguous.
Integer32
Constraints:
range: 1-2147483647
.1.3.6.1.4.1.2352.2.4.1.6.1.1
The description of a temperature test
point. Typically an instance of this object will hold
a user-friendly description of the physical entity
being monitored by this test point.
OctetString
Constraints:
range: 0-48
.1.3.6.1.4.1.2352.2.4.1.6.1.2
The current temperature of this entity in degrees Celsius.
degrees CelsiusRbnTemperature
Type Constraints:
range: 0..100
.1.3.6.1.4.1.2352.2.4.1.6.1.3