RAISECOM-REMOTE-MANAGEMENT-LOCAL-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
15
Rows
15
Columns
134
.1.3.6.1.4.1.8886.1.12.1.2
·
1 row entry
·
14 columns
Uses the raisecom variant from
Command help
/opt/observium/mibs/raisecom.
Walk raisecomRemoteInvariableInfoTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'RAISECOM-REMOTE-MANAGEMENT-LOCAL-MIB' -M '/opt/observium/mibs/raisecom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RAISECOM-REMOTE-MANAGEMENT-LOCAL-MIB::raisecomRemoteInvariableInfoTable'
Basic information of remote devices.
Table entry for basic information of each remote device.
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| raisecomRemoteInvariableInfoIndexObject which specifies a unique entry in the raisecomRemoteTrapEnable. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.8886.1.12.1.2.1.1 | ||||||||
| raisecomRemoteSysOidThe vendor's authoritative identification of the network management subsystem contained in the entity. This value provides an easy and unambiguous means for determining `what kind of box' the remote device is. | ObjectIdentifier | .1.3.6.1.4.1.8886.1.12.1.2.1.2 | ||||||||
| raisecomRemoteModuleTypeThis object specifies module type of remote device. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.8886.1.12.1.2.1.3 | ||||||||
| raisecomRemoteOidCapabilityAn indication of whether the device support OID parse. | SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. | .1.3.6.1.4.1.8886.1.12.1.2.1.4 | ||||||||
| raisecomRemoteFileTransCapabilityAn indication of whether the device support file transfer via oam. | SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. | .1.3.6.1.4.1.8886.1.12.1.2.1.5 | ||||||||
| raisecomRemoteOtherCapabilityThis object specifies oam capbilities set supported by remote device. The value of 2^n (n>=0&&n<32) stands for each oam capability. 2^0 stands for IP configuration capability ,2^1 stands for SNMP community configurati… | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.8886.1.12.1.2.1.6 | ||||||||
| raisecomRemoteMainChipIdThe main chip id of remote device, probably the id of switch chip contained in remote device. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.8886.1.12.1.2.1.7 | ||||||||
| raisecomRemoteFpgaChipIdThe FPGA chip id of remote device. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.8886.1.12.1.2.1.8 | ||||||||
| raisecomRemoteFpgaSwVerThe FPGA software version of remote device. | OctetString | .1.3.6.1.4.1.8886.1.12.1.2.1.9 | ||||||||
| raisecomRemoteSystemSwVerRemote devices system software version. | OctetString | .1.3.6.1.4.1.8886.1.12.1.2.1.10 | ||||||||
| raisecomRemoteSystemHwVerRemote devices system hardware version. | OctetString | .1.3.6.1.4.1.8886.1.12.1.2.1.11 | ||||||||
| raisecomRemotePortNumThe port number of remote device. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.8886.1.12.1.2.1.12 | ||||||||
| raisecomRemoteDeviceNameThe name of remote device. | OctetString | .1.3.6.1.4.1.8886.1.12.1.2.1.13 | ||||||||
| raisecomRemoteInvariableInfoStatusThe status of this invariable information entry. | SWITCH-RMON-MIBEntryStatus Type Values:
| .1.3.6.1.4.1.8886.1.12.1.2.1.14 |
.1.3.6.1.4.1.8886.1.12.1.3
·
1 row entry
·
7 columns
Uses the raisecom variant from
Command help
/opt/observium/mibs/raisecom.
Walk raisecomRemoteEnvironmentTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'RAISECOM-REMOTE-MANAGEMENT-LOCAL-MIB' -M '/opt/observium/mibs/raisecom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RAISECOM-REMOTE-MANAGEMENT-LOCAL-MIB::raisecomRemoteEnvironmentTable'
Environment information of remote devices.
Table entry for environment information of remote devices.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
| raisecomRemoteEnvironmentIndexObject which specifies a unique entry in the raisecomRemoteEnvironmentTable. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.8886.1.12.1.3.1.1 | ||||||
| raisecomRemoteTemperatureThe current environment temperature of remote device. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.8886.1.12.1.3.1.2 | ||||||
| raisecomRemoteVolt3300Current voltage value of 3.3v of remote device. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.8886.1.12.1.3.1.3 | ||||||
| raisecomRemoteVolt2500Current voltage value of 2.5v of remote device. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.8886.1.12.1.3.1.4 | ||||||
| raisecomRemoteVolt1800Current voltage value of 1.8v of remote device. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.8886.1.12.1.3.1.5 | ||||||
| raisecomRemoteVolt1200Current voltage value of 1.2v of remote device. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.8886.1.12.1.3.1.6 | ||||||
| raisecomRemoteVoltNormalThis object specifies whether remote votage is in normal range or not. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.8886.1.12.1.3.1.7 |
.1.3.6.1.4.1.8886.1.12.1.4
·
1 row entry
·
6 columns
Uses the raisecom variant from
Command help
/opt/observium/mibs/raisecom.
Walk raisecomRemoteSysCfgTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'RAISECOM-REMOTE-MANAGEMENT-LOCAL-MIB' -M '/opt/observium/mibs/raisecom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RAISECOM-REMOTE-MANAGEMENT-LOCAL-MIB::raisecomRemoteSysCfgTable'
A table of remote device system config.
Table entry of remote device system config.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| raisecomRemoteSysCfgIndexObject which specifies a unique entry in the raisecomRemoteSysCfgTable. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.8886.1.12.1.4.1.1 | ||||||||
| raisecomRemoteSysOperationSpecifies system command in remote device.Currently,support three types command:reboot,write and erase.Reboot command is used to reset remote device,write is used to save startup-config file in remote device, and erase … | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.8886.1.12.1.4.1.2 | ||||||||
| raisecomRemoteSysOperationStateSpecifies the state of this system operation to remote device. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.8886.1.12.1.4.1.3 | ||||||||
| raisecomRemoteHostNameHost name of Remote device. | OctetStringr/w Constraints: range: 1-32 | .1.3.6.1.4.1.8886.1.12.1.4.1.4 | ||||||||
| raisecomRemoteOamNotificationEnableSpecifies whether or not remote device send OAM notificaton frames. | SWITCH-TCEnableVarr/w Type Values:
| .1.3.6.1.4.1.8886.1.12.1.4.1.5 | ||||||||
| raisecomRemoteMaxAllowedFrameLengthThis object specifies max ethernet frame length of remote device. | SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.8886.1.12.1.4.1.6 |
.1.3.6.1.4.1.8886.1.12.1.5
·
1 row entry
·
3 columns
Uses the raisecom variant from
Command help
/opt/observium/mibs/raisecom.
Walk raisecomRemoteCommunityTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'RAISECOM-REMOTE-MANAGEMENT-LOCAL-MIB' -M '/opt/observium/mibs/raisecom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RAISECOM-REMOTE-MANAGEMENT-LOCAL-MIB::raisecomRemoteCommunityTable'
A table of SNMPv1/v2c community string of remote devices.
Table entry of community of remote devices.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
| raisecomRemoteCommunityIndexObject which specifies a unique entry in the raisecomRemoteCommunityTable. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.8886.1.12.1.5.1.1 | ||||||
| raisecomRemoteCommunityNameThe SNMPv1/v2c community name string in remote device. In remote device's community table,the index of this community is 3,and the view for this community is 'internet'. | OctetStringr/w Constraints: range: 1-20 | .1.3.6.1.4.1.8886.1.12.1.5.1.2 | ||||||
| raisecomRemoteCommunityPermissionThis object specifies the type of access allowed. 'readOnly(1)' allows GET operations (i.e., GET, GET-NEXT, GET-BULK) and 'readWrite(2)' allows both GET and SET operations. | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.8886.1.12.1.5.1.3 |
raisecomRemoteL3Table
table.1.3.6.1.4.1.8886.1.12.1.6
·
1 row entry
·
9 columns
Uses the raisecom variant from
Command help
/opt/observium/mibs/raisecom.
Walk raisecomRemoteL3Table
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'RAISECOM-REMOTE-MANAGEMENT-LOCAL-MIB' -M '/opt/observium/mibs/raisecom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RAISECOM-REMOTE-MANAGEMENT-LOCAL-MIB::raisecomRemoteL3Table'
A table of remote subnet parameters.
Table entry of L3 subnet parameters of remote devices.
Indexes
| Column | Syntax | OID |
|---|---|---|
| raisecomRemoteL3IndexObject which specifies a unique entry in the raisecomRemoteL3Table. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.8886.1.12.1.6.1.1 |
| raisecomRemoteL3IpAddrThe IP Address of remote device. This IP address logically AND'ed with 'raisecomRemoteL3Mask' yields the actual subnet value for this subnet.Set the object as '0.0.0.0' means delete IP address of remote devices | SNMPv2-SMIIpAddressr/w Type Constraints: range: 4 | .1.3.6.1.4.1.8886.1.12.1.6.1.2 |
| raisecomRemoteL3MaskThe subnet mask for this remote subnet. It contains 1's in the bit positions for the net and subnet IDs and 0's in the bit positions for host ID. The 1's must be contiguous, starting with the left most bit. | SNMPv2-SMIIpAddressr/w Type Constraints: range: 4 | .1.3.6.1.4.1.8886.1.12.1.6.1.3 |
| raisecomRemoteL3VidIfaceThis object contains the actual VLAN ID (VID) from 1 to 4094. It is actually the management vlan of remote device. | Integer32r/w Constraints: range: 1-4094 | .1.3.6.1.4.1.8886.1.12.1.6.1.4 |
| raisecomRemoteL3VidMemberPortsThe set of ports which are permanently assigned to the egress list for this VLAN by management.Changes to a bit in this object affect the per-port per-VLAN Registrar control for Registration Fixed for the relevant GVR… | SWITCH-TCPortList Type Constraints: range: 32 | .1.3.6.1.4.1.8886.1.12.1.6.1.5 |
| raisecomRemoteL3VidUntaggedPortsThe set of ports which should transmit egress packets for this VLAN as untagged. The default value of this object for the default VLAN (dot1qVlanIndex = 1) is a string of appropriate length including all ports. The… | SWITCH-TCPortList Type Constraints: range: 32 | .1.3.6.1.4.1.8886.1.12.1.6.1.6 |
| raisecomRemoteL3DefaultGatewayWith this object to Set or get default gateway of remote devices. | SNMPv2-SMIIpAddressr/w Type Constraints: range: 4 | .1.3.6.1.4.1.8886.1.12.1.6.1.7 |
| raisecomRemoteL3ObIpAddrThe out IP Address of remote device. | SNMPv2-SMIIpAddressr/w Type Constraints: range: 4 | .1.3.6.1.4.1.8886.1.12.1.6.1.8 |
| raisecomRemoteL3ObMaskThe subnet mask for this remote subnet. | SNMPv2-SMIIpAddressr/w Type Constraints: range: 4 | .1.3.6.1.4.1.8886.1.12.1.6.1.9 |
raisecomRemotePortTable
table.1.3.6.1.4.1.8886.1.12.1.7
·
1 row entry
·
20 columns
Uses the raisecom variant from
Command help
/opt/observium/mibs/raisecom.
Walk raisecomRemotePortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'RAISECOM-REMOTE-MANAGEMENT-LOCAL-MIB' -M '/opt/observium/mibs/raisecom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RAISECOM-REMOTE-MANAGEMENT-LOCAL-MIB::raisecomRemotePortTable'
A table of remote devices port properties.
Table entry for port control and status information in remote devices.
| Column | Syntax | OID | ||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| raisecomRemoteIfindexThe ifIndex value based 1 which identifies the unique interface of local device. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.8886.1.12.1.7.1.1 | ||||||||||||||||||||
| raisecomRemotePortIfindexThe ifIndex value based 1 which identifies the unique interface of remote device. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.8886.1.12.1.7.1.2 | ||||||||||||||||||||
| raisecomRemotePortTypePort type in remote devices,same as slot type. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.8886.1.12.1.7.1.3 | ||||||||||||||||||||
| raisecomRemotePortNameThe port name of remote devices. | OctetString Constraints: range: 1-32 | .1.3.6.1.4.1.8886.1.12.1.7.1.4 | ||||||||||||||||||||
| raisecomRemotePortAdminStatusThe administrative state of the port on remote devices. | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.8886.1.12.1.7.1.5 | ||||||||||||||||||||
| raisecomRemotePortOperStatusThe current operational state of the interface in remote devices. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.8886.1.12.1.7.1.6 | ||||||||||||||||||||
| raisecomRemotePortDuplexSpeedSetThe desired speed and duplex of the interface in remote devices. | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.8886.1.12.1.7.1.7 | ||||||||||||||||||||
| raisecomRemotePortDuplexSpeedGetThe actual speed and duplex for this interface. If the interface is not configured for an acceptable value, a value of illegal(99) is returned. A value of unknown(1) is returned when the interface is down. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.8886.1.12.1.7.1.8 | ||||||||||||||||||||
| raisecomRemotePortFlowControlEnableSet the flow control on the interface to enable(1) or disable(2). | SWITCH-TCEnableVarr/w Type Values:
| .1.3.6.1.4.1.8886.1.12.1.7.1.9 | ||||||||||||||||||||
| raisecomRemotePortFlowControlStatusThe actual port flow control status of remote device. | SWITCH-TCEnableVar Type Values:
| .1.3.6.1.4.1.8886.1.12.1.7.1.10 | ||||||||||||||||||||
| raisecomRemotePortIngressRateThe value is the ingress rate( Kbps) of the port. | Integer32r/w Constraints: range: 0-1048576 | .1.3.6.1.4.1.8886.1.12.1.7.1.11 | ||||||||||||||||||||
| raisecomRemotePortEgressRateThe value is the egress rate( Kbps) of the port. | Integer32r/w Constraints: range: 0-1048576 | .1.3.6.1.4.1.8886.1.12.1.7.1.12 | ||||||||||||||||||||
| raisecomRemotePortFaultPassEnableSet fault pass to enable(1) or disable(2) on the port in remote device. | SWITCH-TCEnableVarr/w Type Values:
| .1.3.6.1.4.1.8886.1.12.1.7.1.13 | ||||||||||||||||||||
| raisecomRemotePortFaultPassPortsThe ports set which should be down when fault pass occurs.If the value is 0,stands for fault pass function is disable on this port,otherwise fault pass function is enable and the ports set specifies which ports shou… | SWITCH-TCPortListr/w Type Constraints: range: 32 | .1.3.6.1.4.1.8886.1.12.1.7.1.14 | ||||||||||||||||||||
| raisecomRemotePortFaultPassStatusPort state changging result of fault pass. If normal(1), there is no fault pass occurring. If down(2), the port is down because of fault pass occurring. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.8886.1.12.1.7.1.15 | ||||||||||||||||||||
| raisecomRemotePortFaultReturnEnableSet fault return on the port in remote device to enable(1) or disable(2). This value of TP is unavailable. | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.8886.1.12.1.7.1.16 | ||||||||||||||||||||
| raisecomRemotePortFaultReturnStatusPort state changging result of fault return.If normal(1), there is no fault return occurring.If down(2), the port is down result of fault return occurring.This value of TP is unavailable. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.8886.1.12.1.7.1.17 | ||||||||||||||||||||
| raisecomRemotePortSDSD status. This value of TP is unavailable. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.8886.1.12.1.7.1.18 | ||||||||||||||||||||
| raisecomRemoteOptModuleTypeOptical module type of remote device port. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.8886.1.12.1.7.1.19 | ||||||||||||||||||||
| raisecomRemotePortDescrThe description of a port in remote device. | OctetStringr/w Constraints: range: 1-255 | .1.3.6.1.4.1.8886.1.12.1.7.1.20 |
.1.3.6.1.4.1.8886.1.12.1.8
·
1 row entry
·
20 columns
Uses the raisecom variant from
Command help
/opt/observium/mibs/raisecom.
Walk raisecomRemotePortStatsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'RAISECOM-REMOTE-MANAGEMENT-LOCAL-MIB' -M '/opt/observium/mibs/raisecom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RAISECOM-REMOTE-MANAGEMENT-LOCAL-MIB::raisecomRemotePortStatsTable'
A table of remote devices port statistics.
Table entry of remote devices port statistics.
| Column | Syntax | OID |
|---|---|---|
| raisecomRemoteStatsIfindexThe ifIndex value based 1 which identifies the unique interface of local device. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.8886.1.12.1.8.1.1 |
| raisecomRemoteStatsPortIfindexThe ifIndex value based 1 which identifies the unique interface of remote device. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.8886.1.12.1.8.1.2 |
| raisecomRemotePortInOctetsThe total number of octets received on the port. | SNMPv2-SMICounter64 Type Constraints: range: 0..18446744073709551615 | .1.3.6.1.4.1.8886.1.12.1.8.1.3 |
| raisecomRemotePortInPktsThe total number of packets received on the port.. | SNMPv2-SMICounter64 Type Constraints: range: 0..18446744073709551615 | .1.3.6.1.4.1.8886.1.12.1.8.1.4 |
| raisecomRemotePortInUcastPktsThe number of packets, delivered by this sub-layer to a higher (sub-)layer, which were not addressed to a multicast or broadcast address at this sub-layer. | SNMPv2-SMICounter64 Type Constraints: range: 0..18446744073709551615 | .1.3.6.1.4.1.8886.1.12.1.8.1.5 |
| raisecomRemotePortInMulticastPktsThe number of packets, delivered by this sub-layer to a higher (sub-)layer, which were addressed to a multicast address at this sub-layer. For a MAC layer protocol, this includes both Group and Functional addresses | SNMPv2-SMICounter64 Type Constraints: range: 0..18446744073709551615 | .1.3.6.1.4.1.8886.1.12.1.8.1.6 |
| raisecomRemotePortInBroadcastPktsThe number of packets, delivered by this sub-layer to a higher (sub-)layer, which were addressed to a broadcast address at this sub-layer. | SNMPv2-SMICounter64 Type Constraints: range: 0..18446744073709551615 | .1.3.6.1.4.1.8886.1.12.1.8.1.7 |
| raisecomRemotePortOutOctetsThe total number of octets transmitted out of the port, including framing characters. | SNMPv2-SMICounter64 Type Constraints: range: 0..18446744073709551615 | .1.3.6.1.4.1.8886.1.12.1.8.1.8 |
| raisecomRemotePortOutPktsThe total number of packets transmitted out of the port. | SNMPv2-SMICounter64 Type Constraints: range: 0..18446744073709551615 | .1.3.6.1.4.1.8886.1.12.1.8.1.9 |
| raisecomRemotePortOutUcastPktsThe total number of packets that higher-level protocols requested be transmitted, and which were not addressed to a multicast or broadcast address at this sub-layer, including those that were discarded or not sent. | SNMPv2-SMICounter64 Type Constraints: range: 0..18446744073709551615 | .1.3.6.1.4.1.8886.1.12.1.8.1.10 |
| raisecomRemotePortOutMulticastPktsThe total number of packets that higher-level protocols requested be transmitted, and which were addressed to a multicast address at this sub-layer, including those that were discarded or not sent. For a MAC layer pro… | SNMPv2-SMICounter64 Type Constraints: range: 0..18446744073709551615 | .1.3.6.1.4.1.8886.1.12.1.8.1.11 |
| raisecomRemotePortOutBroadcastPktsThe total number of packets that higher-level protocols requested be transmitted, and which were addressed to a broadcast address at this sub-layer, including those that were discarded or not sent. | SNMPv2-SMICounter64 Type Constraints: range: 0..18446744073709551615 | .1.3.6.1.4.1.8886.1.12.1.8.1.12 |
| raisecomRemotePortErrorPktsThe total number of bad packets received by a specific port of remote device. | SNMPv2-SMICounter32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.8886.1.12.1.8.1.13 |
| raisecomRemotePortDropEventsThe total number of events in which packets were dropped by the probe due to lack of resources. Note that this number is not necessarily the number of packets dropped; it is just the number of times this condition h… | SNMPv2-SMICounter32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.8886.1.12.1.8.1.14 |
| raisecomRemotePortCRCAlignErrorsThe total number of packets received that had a length (excluding framing bits, but including FCS octets) of between 64 and 1518 octets, inclusive, but but had either a bad Frame Check Sequence (FCS) with an integral n… | SNMPv2-SMICounter32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.8886.1.12.1.8.1.15 |
| raisecomRemotePortUndersizePktsThe total number of packets received that were less than 64 octets long (excluding framing bits, but including FCS octets) and were otherwise well formed. | SNMPv2-SMICounter32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.8886.1.12.1.8.1.16 |
| raisecomRemotePortOversizePktsThe total number of packets received that were longer than 1518 octets (excluding framing bits, but including FCS octets) and were otherwise well formed. | SNMPv2-SMICounter32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.8886.1.12.1.8.1.17 |
| raisecomRemotePortFragmentsThe total number of packets received that were less than 64 octets in length (excluding framing bits but including FCS octets) and had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Er… | SNMPv2-SMICounter32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.8886.1.12.1.8.1.18 |
| raisecomRemotePortJabbersThe total number of packets received that were longer than 1518 octets (excluding framing bits, but including FCS octets), and had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or… | SNMPv2-SMICounter32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.8886.1.12.1.8.1.19 |
| raisecomRemotePortCollisionsThe best estimate of the total number of collisions on this Ethernet segment. | SNMPv2-SMICounter32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.8886.1.12.1.8.1.20 |
raisecomRemoteSfpTable
table.1.3.6.1.4.1.8886.1.12.1.9
·
1 row entry
·
15 columns
Uses the raisecom variant from
Command help
/opt/observium/mibs/raisecom.
Walk raisecomRemoteSfpTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'RAISECOM-REMOTE-MANAGEMENT-LOCAL-MIB' -M '/opt/observium/mibs/raisecom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RAISECOM-REMOTE-MANAGEMENT-LOCAL-MIB::raisecomRemoteSfpTable'
The table of remote devices SFP information.
Table entry of remote devices SFP information table.
Indexes
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| raisecomRemoteSfpInterfaceIdThis object based 1 identifies the remote port ID of SFP module location. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.8886.1.12.1.9.1.1 | ||||||||||||
| raisecomRemoteSfpExistThis object specifies whether remote SFP module exist. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.8886.1.12.1.9.1.2 | ||||||||||||
| raisecomRemoteSfpMediaTypeThis object specifies the media type of remote SFP module. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.8886.1.12.1.9.1.3 | ||||||||||||
| raisecomRemoteSfpRXLOSThis object specifies the RX status of remote SFP module. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.8886.1.12.1.9.1.4 | ||||||||||||
| raisecomRemoteSfpTXFaultThis object specifies the TX status of remote SFP module. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.8886.1.12.1.9.1.5 | ||||||||||||
| raisecomRemoteSfpTXDisableDisable or enable the TX of remote SFP module. | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.8886.1.12.1.9.1.6 | ||||||||||||
| raisecomRemoteSfpModuleTypeThis object specifies the remote SFP module type. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.8886.1.12.1.9.1.7 | ||||||||||||
| raisecomRemoteSfpOpticalInterfaceThis object specifies the optical interface type of remote SFP module. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.8886.1.12.1.9.1.8 | ||||||||||||
| raisecomRemoteSfpSpeedStatusThis object specifies the speed of remote SFP module. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.8886.1.12.1.9.1.9 | ||||||||||||
| raisecomRemoteSfpTransportDistanceThis object specifies the transport distance of remote SFP module. | Integer32 Constraints: range: 0-255 | .1.3.6.1.4.1.8886.1.12.1.9.1.10 | ||||||||||||
| raisecomRemoteSfpWaveLengthThis object specifies the wave length of remote SFP module. | Integer32 Constraints: range: 0-65535 | .1.3.6.1.4.1.8886.1.12.1.9.1.11 | ||||||||||||
| raisecomRemoteSfpVendorThis object specifies the vendor name of remote SFP module. | OctetString Constraints: range: 0-16 | .1.3.6.1.4.1.8886.1.12.1.9.1.12 | ||||||||||||
| raisecomRemoteSfpProductTypeThis object specifies the product type of remote SFP module. | OctetString Constraints: range: 0-16 | .1.3.6.1.4.1.8886.1.12.1.9.1.13 | ||||||||||||
| raisecomRemoteSfpVersionThis object specifies the version of remote SFP module. | OctetString Constraints: range: 0-4 | .1.3.6.1.4.1.8886.1.12.1.9.1.14 | ||||||||||||
| raisecomRemoteSfpSerialNumberThis object specifies the serial number of remote SFP module. | OctetString Constraints: range: 0-16 | .1.3.6.1.4.1.8886.1.12.1.9.1.15 |
raisecomRemoteDtTable
table.1.3.6.1.4.1.8886.1.12.1.10
·
1 row entry
·
4 columns
Uses the raisecom variant from
Command help
/opt/observium/mibs/raisecom.
Walk raisecomRemoteDtTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'RAISECOM-REMOTE-MANAGEMENT-LOCAL-MIB' -M '/opt/observium/mibs/raisecom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RAISECOM-REMOTE-MANAGEMENT-LOCAL-MIB::raisecomRemoteDtTable'
The table of remote devices Q-in-Q.
Table entry of remote devices Q-in-Q table.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
| raisecomRemoteDtSwitchModeThis object identifies the switch mode of remote device. | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.8886.1.12.1.10.1.1 | ||||||
| raisecomRemoteDtOuterTpidThis object identifies the outer tpid of remote device. | Integer32r/w Constraints: range: 0-65535 | .1.3.6.1.4.1.8886.1.12.1.10.1.2 | ||||||
| raisecomRemoteDtNativeVlanThis object identifies the native vlan ID of remote device. On transparent mode, the native vlan is useless; on dot1q-vlan mode, the ingress packets without tag of acess ports is tagged with the native vlan ID; on do… | Integer32r/w Constraints: range: 1-4094 | .1.3.6.1.4.1.8886.1.12.1.10.1.3 | ||||||
| raisecomRemoteDtAccessPortThis object identifies vlan acess port of remote device. | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.8886.1.12.1.10.1.4 |
.1.3.6.1.4.1.8886.1.12.1.11
·
1 row entry
·
1 columns
Uses the raisecom variant from
Command help
/opt/observium/mibs/raisecom.
Walk raisecomRemoteSendConfTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'RAISECOM-REMOTE-MANAGEMENT-LOCAL-MIB' -M '/opt/observium/mibs/raisecom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RAISECOM-REMOTE-MANAGEMENT-LOCAL-MIB::raisecomRemoteSendConfTable'
The table for send configuration to remote devices
Table entry for send cofiguration to remote devices.
Indexes
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| raisecomRemoteSendConfThis object is used to send config frame to remote device and to save config frame local. | RcRemoteConfigFrameSendStatusr/w Type Values:
Description: Specifies the status of send config packet to the remote device. The value 'send' means the config packet should be sent to the remote device and not saved. The value 'save' means the config packet is just saved as def… | .1.3.6.1.4.1.8886.1.12.1.11.1.1 |
.1.3.6.1.4.1.8886.1.12.1.12
·
1 row entry
·
4 columns
Uses the raisecom variant from
Command help
/opt/observium/mibs/raisecom.
Walk raisecomRemoteInLoopbackTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'RAISECOM-REMOTE-MANAGEMENT-LOCAL-MIB' -M '/opt/observium/mibs/raisecom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RAISECOM-REMOTE-MANAGEMENT-LOCAL-MIB::raisecomRemoteInLoopbackTable'
The table of remote devices inside loopback.
Table entry of remote devices inside loopback.
Indexes
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| raisecomRemoteInLoopbackMacExchangeAn indication of whether the remote device exchange MAC address when loopbacking. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.8886.1.12.1.12.1.1 | ||||||||||
| raisecomRemoteInLoopbackCrcRecalSetThis object is used to set whether the remote device recalculate CRC when loopbacking. This object represents the desired configuration when initiate remote inside loopback. | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.8886.1.12.1.12.1.2 | ||||||||||
| raisecomRemoteInLoopbackCrcRecalAn indication of whether the remote device recalculate CRC when loopbacking. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.8886.1.12.1.12.1.3 | ||||||||||
| raisecomRemoteInLoopbackStatusBy this object can initiate or terminate remote inside loopback,also can get remote device loopback status. | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.8886.1.12.1.12.1.4 |
raisecomRemoteVctTable
table.1.3.6.1.4.1.8886.1.12.1.13
·
1 row entry
·
3 columns
Uses the raisecom variant from
Command help
/opt/observium/mibs/raisecom.
Walk raisecomRemoteVctTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'RAISECOM-REMOTE-MANAGEMENT-LOCAL-MIB' -M '/opt/observium/mibs/raisecom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RAISECOM-REMOTE-MANAGEMENT-LOCAL-MIB::raisecomRemoteVctTable'
The table of remote devices VCT information.
Table entry of remote devices VCT table.
Indexes
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| raisecomRemoteVctAttributeThis object identifies the VCT attribute of remote device. | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.8886.1.12.1.13.1.1 | ||||||||||
| raisecomRemoteVctStatusThis object identifies the VCT status of remote device. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.8886.1.12.1.13.1.2 | ||||||||||
| raisecomRemoteVctLengthThis object identifies the VCT length of remote device. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.8886.1.12.1.13.1.3 |
.1.3.6.1.4.1.8886.1.12.1.14
·
1 row entry
·
12 columns
Uses the raisecom variant from
Command help
/opt/observium/mibs/raisecom.
Walk raisecomRemoteVlanConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'RAISECOM-REMOTE-MANAGEMENT-LOCAL-MIB' -M '/opt/observium/mibs/raisecom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RAISECOM-REMOTE-MANAGEMENT-LOCAL-MIB::raisecomRemoteVlanConfigTable'
The table of remote devices vlan information.
Table entry of remote devices vlan table.
Indexes
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| raisecomRemoteVlanStatusThis object identifies the vlan status of remote device. | RcRemoteVlanStatusr/w Type Values:
Description: Specifies the status of vlan to be performed. The value 'vlan-forbid' will forbid vlan function in the equipment. The value 'vlan-dot1q' will allow 802.1Q vlan function to work in the equipment. The value 'vlan-port'… | .1.3.6.1.4.1.8886.1.12.1.14.1.1 | ||||||||||||
| raisecomRemoteCosStatusThis object identifies the 802.1p COS status of remote device. TRUE means cos is forbidden to be used. FALSE means cos is allowed to be used | SNMPv2-TCTruthValuer/w Type Values:
Description: Represents a boolean value. | .1.3.6.1.4.1.8886.1.12.1.14.1.2 | ||||||||||||
| raisecomRemoteFiberPortTagTypeThis object identifies the attribute of Fiber Ports' tag in remote device. | RcRemotePortTagStatusr/w Type Values:
Description: Specifies the status of tag in the port. The value 'untag' means there is no tags in the port. The value 'tag' means there is a tag in the port. | .1.3.6.1.4.1.8886.1.12.1.14.1.3 | ||||||||||||
| raisecomRemoteFiberPortPriorityThis object identifies the Priority of Fiber Ports' tag in remote device. The default value is '0' | Integer32r/w Constraints: range: 0-7 | .1.3.6.1.4.1.8886.1.12.1.14.1.4 | ||||||||||||
| raisecomRemoteFiberPortPvidThis object identifies the Pvid of Fiber Ports' tag in remote device. The default value is '1' | Integer32r/w Constraints: range: 1-4094 | .1.3.6.1.4.1.8886.1.12.1.14.1.5 | ||||||||||||
| raisecomRemoteCablePortTagTypeThis object identifies the attribute of Cable Ports' tag in remote device. | RcRemotePortTagStatusr/w Type Values:
Description: Specifies the status of tag in the port. The value 'untag' means there is no tags in the port. The value 'tag' means there is a tag in the port. | .1.3.6.1.4.1.8886.1.12.1.14.1.6 | ||||||||||||
| raisecomRemoteCablePortPriorityThis object identifies the Priority of Cable Ports' tag in remote device. The default value is '0' | Integer32r/w Constraints: range: 0-7 | .1.3.6.1.4.1.8886.1.12.1.14.1.7 | ||||||||||||
| raisecomRemoteCablePortPvidThis object identifies the Pvid of Cable Ports' tag in remote device. The default value is '1' | Integer32r/w Constraints: range: 1-4094 | .1.3.6.1.4.1.8886.1.12.1.14.1.8 | ||||||||||||
| raisecomRemoteCpuPortTagTypeThis object identifies the attribute of Cpu Ports' tag in remote device. | RcRemotePortTagStatusr/w Type Values:
Description: Specifies the status of tag in the port. The value 'untag' means there is no tags in the port. The value 'tag' means there is a tag in the port. | .1.3.6.1.4.1.8886.1.12.1.14.1.9 | ||||||||||||
| raisecomRemoteCpuPortPriorityThis object identifies the Priority of Cpu Ports' tag in remote device. The default value is '0' | Integer32r/w Constraints: range: 0-7 | .1.3.6.1.4.1.8886.1.12.1.14.1.10 | ||||||||||||
| raisecomRemoteCpuPortPvidThis object identifies the Pvid of Cpu Ports' tag in remote device. The default value is '1' | Integer32r/w Constraints: range: 1-4094 | .1.3.6.1.4.1.8886.1.12.1.14.1.11 | ||||||||||||
| raisecomRemoteSendVlanConfThis object is used to send vlan config frame to remote device and to save the config frame local. | RcRemoteConfigFrameSendStatusr/w Type Values:
Description: Specifies the status of send config packet to the remote device. The value 'send' means the config packet should be sent to the remote device and not saved. The value 'save' means the config packet is just saved as def… | .1.3.6.1.4.1.8886.1.12.1.14.1.12 |
.1.3.6.1.4.1.8886.1.12.1.15
·
1 row entry
·
3 columns
Uses the raisecom variant from
Command help
/opt/observium/mibs/raisecom.
Walk raisecomRemoteVlanGroupTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'RAISECOM-REMOTE-MANAGEMENT-LOCAL-MIB' -M '/opt/observium/mibs/raisecom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RAISECOM-REMOTE-MANAGEMENT-LOCAL-MIB::raisecomRemoteVlanGroupTable'
The table of remote devices vlan information.
Table entry of remote devices vlan group table.
| Column | Syntax | OID |
|---|---|---|
| raisecomRemoteVlanGroupIndexThis object identifies the index of vlan group in remote device. | Integer32 Constraints: range: 0-15 | .1.3.6.1.4.1.8886.1.12.1.15.1.1 |
| raisecomRemoteVlanIdThis object identifies the vlan id of the specify vlan group. The default vlan id of group is 1 and other group's default vlan id is 0 . | Integer32r/w Constraints: range: 0-4094 | .1.3.6.1.4.1.8886.1.12.1.15.1.2 |
| raisecomRemoteVlanMemberThis object identifies the ports belong to the vlan group. If the frist bit is '1' means fiber port belongs to the vlan group. If the second bit is '1' means cable port belongs to the vlan group. If the third bit is '1'… | Integer32r/w Constraints: range: 0-7 | .1.3.6.1.4.1.8886.1.12.1.15.1.3 |
.1.3.6.1.4.1.8886.1.12.1.16
·
1 row entry
·
13 columns
Uses the raisecom variant from
Command help
/opt/observium/mibs/raisecom.
Walk raisecomRemoteSfpDdmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'RAISECOM-REMOTE-MANAGEMENT-LOCAL-MIB' -M '/opt/observium/mibs/raisecom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RAISECOM-REMOTE-MANAGEMENT-LOCAL-MIB::raisecomRemoteSfpDdmTable'
The table of remote devices digital detect management information.
Table entry of remote devices digital detect management table.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
| raisecomRemoteSfpDdmValidThis object identifies the SFM in remote device is valid. | SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. | .1.3.6.1.4.1.8886.1.12.1.16.1.1 | ||||||
| raisecomRemoteSfpDdmModeThis object identifies the mode of SFP in remote device. | RcRemoteSfpDdmMode Type Values:
Description: Specifies the mode of SFP DDM. The value 'unknown' means the remote SFP DDM mode is unknown. The value 'inside' means the remote SFP DDM mode is inside. The value 'outside' means the remote SFP DDM mode is outside. | .1.3.6.1.4.1.8886.1.12.1.16.1.2 | ||||||
| raisecomRemoteSfpDdmTemperatureThis object identifies temperature of SFP in remote device. A unit is a ??(1/1000Celsius). | Integer32 Constraints: range: -128000-127996 | .1.3.6.1.4.1.8886.1.12.1.16.1.3 | ||||||
| raisecomRemoteSfpDdmSupplyVoltThis object identifies the volt of SFP in remote device. A unit is 100uV. | Integer32 Constraints: range: 0-65500 | .1.3.6.1.4.1.8886.1.12.1.16.1.4 | ||||||
| raisecomRemoteSfpDdmBiasCurrentThis object identifies the bias current of SFP in remote device. A unit is 2uA. | Integer32 Constraints: range: 0-65500 | .1.3.6.1.4.1.8886.1.12.1.16.1.5 | ||||||
| raisecomRemoteSfpDdmOpticalTxPowerThis object identifies the optical transmit power of SFP in remote device. A unit is 0.1uW. | Integer32 Constraints: range: 0-65535 | .1.3.6.1.4.1.8886.1.12.1.16.1.6 | ||||||
| raisecomRemoteSfpDdmOpticalRxPowerThis object identifies the optical receive power of SFP in remote device. A unit is 0.1uW. | Integer32 Constraints: range: 0-65535 | .1.3.6.1.4.1.8886.1.12.1.16.1.7 | ||||||
| raisecomRemoteSfpDdmAlarmThis object identifies the SFP alarm is occur. | SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. | .1.3.6.1.4.1.8886.1.12.1.16.1.8 | ||||||
| raisecomRemoteSfpDdmAlarmTemStatusThis object identifies the SFP alarm status of tempreture in remote device. | RcRemoteSfpDdmAlarmStatus Type Values:
Description: Specifies the status of SFP DDM alarm. The value 'normal' means the remote SFP DDM is normal. The value 'low' means the remote SFP DDM is lower than threshold. The value 'high' means the remote SFP DDM is higher than… | .1.3.6.1.4.1.8886.1.12.1.16.1.9 | ||||||
| raisecomRemoteSfpDdmAlarmVoltStatusThis object identifies the SFP alarm status of volt in remote device. | RcRemoteSfpDdmAlarmStatus Type Values:
Description: Specifies the status of SFP DDM alarm. The value 'normal' means the remote SFP DDM is normal. The value 'low' means the remote SFP DDM is lower than threshold. The value 'high' means the remote SFP DDM is higher than… | .1.3.6.1.4.1.8886.1.12.1.16.1.10 | ||||||
| raisecomRemoteSfpDdmAlarmCurrentStatusThis object identifies the SFP alarm status of current in remote device. | RcRemoteSfpDdmAlarmStatus Type Values:
Description: Specifies the status of SFP DDM alarm. The value 'normal' means the remote SFP DDM is normal. The value 'low' means the remote SFP DDM is lower than threshold. The value 'high' means the remote SFP DDM is higher than… | .1.3.6.1.4.1.8886.1.12.1.16.1.11 | ||||||
| raisecomRemoteSfpDdmAlarmTxPowerStatusThis object identifies the SFP alarm status of transmit power in remote device. | RcRemoteSfpDdmAlarmStatus Type Values:
Description: Specifies the status of SFP DDM alarm. The value 'normal' means the remote SFP DDM is normal. The value 'low' means the remote SFP DDM is lower than threshold. The value 'high' means the remote SFP DDM is higher than… | .1.3.6.1.4.1.8886.1.12.1.16.1.12 | ||||||
| raisecomRemoteSfpDdmAlarmRxPowerStatusThis object identifies the SFP alarm status of receive power in remote device. | RcRemoteSfpDdmAlarmStatus Type Values:
Description: Specifies the status of SFP DDM alarm. The value 'normal' means the remote SFP DDM is normal. The value 'low' means the remote SFP DDM is lower than threshold. The value 'high' means the remote SFP DDM is higher than… | .1.3.6.1.4.1.8886.1.12.1.16.1.13 |