rbResetOn
| .1.3.6.1.4.1.12394.1.2.0.1 | This trap is sent when the device/card is going to perform reset.
rbTrapSource = NPU/AU/SU
rbTrapSeverity = Info
rbTrapCategory = Equipment
rbTrapAdditionalInfo = 1..2 for external/internal fault. |
rbSwDownloadStart
| .1.3.6.1.4.1.12394.1.2.0.101 | Software download process is started.
rbTrapSource = NPU/AU/SU
rbTrapSeverity = Info,
rbTrapCategory = PROC |
rbSwDownloadEnd
| .1.3.6.1.4.1.12394.1.2.0.102 | Software download process is finished
rbTrapSource = NPU/AU/SU
rbTrapSeverity = Info,
rbTrapCategory = PROC |
rbSwDownloadError
| .1.3.6.1.4.1.12394.1.2.0.103 | Software download process error.
rbTrapSource = NPU/AU/SU
rbTrapSeverity = Minor,
rbTrapCategory = PROC
rbTrapAdditionalInfo =100..103 |
rbSwSwitchFailed
| .1.3.6.1.4.1.12394.1.2.0.104 | Software switch over failed.
rbTrapSource = NPU/AU/SU
rbTrapSeverity = Minor,
rbTrapCategory = PROC,
rbTrapAdditionalInfo = 104..105 |
rbSwSwitchSucceed
| .1.3.6.1.4.1.12394.1.2.0.105 | Software switch over succeeded ,
rbTrapSource = NPU/AU/SU
rbTrapSeverity = Info,
rbTrapCategory = PROC,
rbTrapAdditionalInfo = |
rbBERTestFinished
| .1.3.6.1.4.1.12394.1.2.0.106 | BER Test is finished ,
rbTrapSource = SU
rbTrapSeverity = Info,
rbTrapCategory = PROC |
rbBERTestStarted
| .1.3.6.1.4.1.12394.1.2.0.107 | BER Test is started ,
rbTrapSource = SU
rbTrapSeverity = Info,
rbTrapCategory = PROC |
rbSwFileConflict
| .1.3.6.1.4.1.12394.1.2.0.108 | AU configured SW file and AU HW mismatch,
rbTrapSource = AU/SU
rbTrapSeverity = Minor,
rbTrapCategory = PROC |
rbXMLDownloadResult
| .1.3.6.1.4.1.12394.1.2.0.109 | XML File Download status.
rbTrapSource = NPU
rbTrapSeverity = Info,
rbTrapCategory = PROC,
rbTrapAdditionalInfo = 220..224 |
rbFreqBandDownloadResult
| .1.3.6.1.4.1.12394.1.2.0.110 | Frequency Band File Download status.
rbTrapSource = NPU
rbTrapSeverity = Info,
rbTrapCategory = PROC,
rbTrapAdditionalInfo = 220..222,224 |
rbServiceDown
| .1.3.6.1.4.1.12394.1.2.0.111 | The Service is down or didn't start,
rbTrapSource = NPU,
rbTrapSeverity = Major,
rbTrapCategory = QoS |
rbServiceUp
| .1.3.6.1.4.1.12394.1.2.0.112 | The Service is operational,
rbTrapSource = NPU,
rbTrapSeverity = Info,
rbTrapCategory = QoS |
rbServiceChanged
| .1.3.6.1.4.1.12394.1.2.0.113 | The Service was modified,
rbTrapSource = NPU,
rbTrapSeverity = Info,
rbTrapCategory = QoS,
rbTrapAdditionalInfo = 119..122 |
rbServiceGeneralError
| .1.3.6.1.4.1.12394.1.2.0.114 | Service error was detected,
rbTrapSource = NPU,
rbTrapSeverity = Minor,
rbTrapCategory = QoS
rbTrapAdditionalInfo =111..118. |
rbNetworkingError
| .1.3.6.1.4.1.12394.1.2.0.115 | Loop was detected on SU Ethernet port,
rbTrapSource = SU
rbTrapSeverity = Info,
rbTrapCategory = PROC,
rbTrapAdditionalInfo = 10.. |
rbSwitchedAuthenticationServer
| .1.3.6.1.4.1.12394.1.2.0.117 | RADIUS Client switched to another Authentication Server,
rbTrapSource = NPU
rbTrapSeverity = Info,
rbTrapCategory = COMM |
rbSwitchedAccountingServer
| .1.3.6.1.4.1.12394.1.2.0.118 | RADIUS Client switched to another Accounting Server,
rbTrapSource = NPU
rbTrapSeverity = Info,
rbTrapCategory = COMM |
rbServiceEstablishmentFailure
| .1.3.6.1.4.1.12394.1.2.0.119 | Service establishment failure,
rbTrapSource = NPU,
rbTrapSeverity = Minor,
rbTrapCategory = QoS
rbTrapAdditionalInfo = 200 .. 210, 214
rbServiceIdx = Service Profile Idx,
rbServiceName = Service Name is created from User Name(SU MAC) and Service Pipe index. |
rbUserAuthenticationTimeout
| .1.3.6.1.4.1.12394.1.2.0.120 | User authentication timeout,
rbTrapSource = NPU
rbTrapSeverity = Info,
rbTrapCategory = COMM,
rbTrapAdditionalInfo = 211 .. 213,
rbSuMacAddr = SU MAC. |
rbUserAuthenticationReject
| .1.3.6.1.4.1.12394.1.2.0.121 | User authentication rejected,
rbTrapSource = NPU
rbTrapSeverity = Info,
rbTrapCategory = COMM,
rbSuMacAddr = SU MAC. |
rbAuthenticationServerKeepAliveTimeoutOn
| .1.3.6.1.4.1.12394.1.2.0.122 | Authentication Server Keep Alive Timeout was detected,
rbTrapSource = NPU,
rbTrapSeverity = Major,
rbTrapCategory = Equipment,
rbRadiusAuthServerAddress = Server IP Address. |
rbAuthenticationServerKeepAliveTimeoutOff
| .1.3.6.1.4.1.12394.1.2.0.123 | Previously detected Authentication Server Keep Alive Timeout terminated,
rbTrapSource = NPU,
rbTrapSeverity = Info,
rbTrapCategory = Equipment,
rbRadiusAuthServerAddress = Server IP Address. |
rbAccountingServerKeepAliveTimeoutOn
| .1.3.6.1.4.1.12394.1.2.0.124 | Accounting Server Keep Alive Timeout was detected,
rbTrapSource = NPU,
rbTrapSeverity = Major,
rbTrapCategory = Equipment,
rbRadiusAcctServerAddress = Server IP Address. |
rbAccountingServerKeepAliveTimeoutOff
| .1.3.6.1.4.1.12394.1.2.0.125 | Previously detected Accounting Server Keep Alive Timeout terminated,
rbTrapSource = NPU,
rbTrapSeverity = Info,
rbTrapCategory = Equipment,
rbRadiusAcctServerAddress = Server IP Address. |
rbExternal1PPSFailureOn
| .1.3.6.1.4.1.12394.1.2.0.134 | External 1PPS failure was detected.
BS will produce this alarm only if external 1PPS clock is enabled,
rbTrapSource = NPU,
rbTrapSeverity = Major,
rbTrapCategory = Equipment. |
rbExternal1PPSFailureOff
| .1.3.6.1.4.1.12394.1.2.0.135 | Previously detected External 1PPS failure terminated,
rbTrapSource = NPU,
rbTrapSeverity = Info,
rbTrapCategory = Equipment. |
rbInternal1PPSFailureOn
| .1.3.6.1.4.1.12394.1.2.0.136 | Internal NPU 1PPS failure was detected,
rbTrapSource = NPU,
rbTrapSeverity = Major,
rbTrapCategory = Equipment. |
rbInternal1PPSFailureOff
| .1.3.6.1.4.1.12394.1.2.0.137 | Internal NPU 1PPS failure terminated,
rbTrapSource = NPU,
rbTrapSeverity = Info,
rbTrapCategory = Equipment. |
rbExternal16MHzFailureOn
| .1.3.6.1.4.1.12394.1.2.0.138 | External 16MHz failure was detected.
BS will produce this alarm only if external 16MHz clock is enabled,
rbTrapSource = NPU,
rbTrapSeverity = Major,
rbTrapCategory = Equipment. |
rbExternal16MHzFailureOff
| .1.3.6.1.4.1.12394.1.2.0.139 | External 16MHz failure terminated,
rbTrapSource = NPU,
rbTrapSeverity = Info,
rbTrapCategory = Equipment. |
rbInternal16MHzFailureOn
| .1.3.6.1.4.1.12394.1.2.0.140 | Internal NPU 16MHz failure was detected. Can be produced by all types of BSs,
rbTrapSource = NPU,
rbTrapSeverity = Major,
rbTrapCategory = Equipment. |
rbInternal16MHzFailureOff
| .1.3.6.1.4.1.12394.1.2.0.141 | Internal NPU 16MHz failure terminated,
rbTrapSource = NPU,
rbTrapSeverity = Info,
rbTrapCategory = Equipment. |
rbGPSComFailureOn
| .1.3.6.1.4.1.12394.1.2.0.142 | GPS Com failure was detected. Can be produced only if GPS type is Trimble,
rbTrapSource = NPU,
rbTrapSeverity = Major,
rbTrapCategory = Equipment. |
rbGPSComFailureOff
| .1.3.6.1.4.1.12394.1.2.0.143 | GPS Com failure terminated,
rbTrapSource = NPU,
rbTrapSeverity = Info,
rbTrapCategory = Equipment. |
rbGPSHealthyFailureOn
| .1.3.6.1.4.1.12394.1.2.0.144 | GPS Healthy failure was detected. Can be produced only if GPS type is Trimble,
rbTrapSource = NPU,
rbTrapSeverity = Major,
rbTrapCategory = Equipment. |
rbGPSHealthyFailureOff
| .1.3.6.1.4.1.12394.1.2.0.145 | GPS Healthy failure terminated,
rbTrapSource = NPU,
rbTrapSeverity = Info,
rbTrapCategory = Equipment. |
rbMin4SatSyncFailureOn
| .1.3.6.1.4.1.12394.1.2.0.146 | Min4SatSync failure was detected.
This indicated that less than four satellites are received by the GPS.
Can be produced only if GPS type is Trimble,
rbTrapSource = NPU,
rbTrapSeverity = Major,
rbTrapCategory = Equipment. |
rbMin4SatSyncFailureOff
| .1.3.6.1.4.1.12394.1.2.0.147 | Min4SatSync failure terminated,
rbTrapSource = NPU,
rbTrapSeverity = Info,
rbTrapCategory = Equipment. |
rbAUExternal1PPSFailureOn
| .1.3.6.1.4.1.12394.1.2.0.148 | External 1PPS failure was detected.
Can be produced by AU when the selected 1PPS arriving from active NPU is failed,
rbTrapSource = AU,
rbTrapSeverity = Major,
rbTrapCategory = Equipment. |
rbAUExternal1PPSFailureOff
| .1.3.6.1.4.1.12394.1.2.0.149 | External 1PPS failure terminated,
rbTrapSource = AU,
rbTrapSeverity = Info,
rbTrapCategory = Equipment. |
rbAUHoldOverEnteredOn
| .1.3.6.1.4.1.12394.1.2.0.150 | HoldOver Entered was detected.
Can be produced by AU when the AU goes to holdover,
rbTrapSource = AU,
rbTrapSeverity = Major,
rbTrapCategory = Equipment. |
rbAUHoldOverEnteredOff
| .1.3.6.1.4.1.12394.1.2.0.151 | HoldOver Entered terminated,
rbTrapSource = AU,
rbTrapSeverity = Info,
rbTrapCategory = Equipment. |
rbAUHoldOverTimeoutPassedOn
| .1.3.6.1.4.1.12394.1.2.0.152 | HoldOver passed was detected.
Can be produced by AU when the AU holdover passed the Timeout,
rbTrapSource = AU,
rbTrapSeverity = Major,
rbTrapCategory = Equipment. |
rbAUHoldOverTimeoutPassedOff
| .1.3.6.1.4.1.12394.1.2.0.153 | HoldOver passed terminated,
rbTrapSource = AU,
rbTrapSeverity = Info,
rbTrapCategory = Equipment. |
rbAUHoldOverTxStoppedOn
| .1.3.6.1.4.1.12394.1.2.0.154 | HoldOver passed and Stop TX operation was detected,
rbTrapSource = AU,
rbTrapSeverity = Major,
rbTrapCategory = Equipment. |
rbAUHoldOverTxStoppedOff
| .1.3.6.1.4.1.12394.1.2.0.155 | Stop TX operation terminated,
rbTrapSource = AU,
rbTrapSeverity = Info,
rbTrapCategory = Equipment. |
rbDiagnosticsHwFaultOn
| .1.3.6.1.4.1.12394.1.2.0.2 | Device/card has detected hardware fault.
rbTrapSource = NPU/AU/SU
rbTrapSeverity = Major
rbTrapCategory = Equipment
rbTrapAdditionalInfo = 3..8,23..27. |
rbShelfCardExtractionOn
| .1.3.6.1.4.1.12394.1.2.0.21 | Card is extracted from the shelf.
rbTrapSource = NPU/AU/PSU/PIU/ACU
rbTrapSeverity = Info,
rbTrapCategory = Equipment |
rbShelfCardInsertionOn
| .1.3.6.1.4.1.12394.1.2.0.22 | Card is inserted in the shelf.
rbTrapSource = NPU/AU/PSU/PIU/ACU
rbTrapSeverity = Info,
rbTrapCategory = Equipment |
rbShelfPeripheralEquipmentFaultOn
| .1.3.6.1.4.1.12394.1.2.0.23 | Fault is detected in one of the Shelf Peripheral Equipment Units.
rbTrapSource = PSU#/PIU#/ACU#/ACU-FAN#/AU
rbTrapSeverity = Minor,
rbTrapCategory = Equipment
rbTrapAdditionalInfo = 53..55 |
rbShelfPeripherallEquipmentFaultOff
| .1.3.6.1.4.1.12394.1.2.0.24 | Previously detected fault in one of the shelf Peripheral Equipment Units is terminated.
rbTrapSource = PSU#/PIU#/ACU#/AU
rbTrapSeverity = Info,
rbTrapCategory = Equipment
rbTrapAdditionalInfo = 53..55 |
rbShelfEnvParamFaultOn
| .1.3.6.1.4.1.12394.1.2.0.25 | Fault is detected in the shelf environment parameter.
rbTrapSource = NPU
rbTrapSeverity = Info,
rbTrapCategory = Equipment
rbTrapAdditionalInfo = 73..76 |
rbShelfEnvParamFaultOff
| .1.3.6.1.4.1.12394.1.2.0.26 | Previously detected environment parameter fault is terminated.
rbTrapSource = NPU
rbTrapSeverity = Info,
rbTrapCategory = Equipment
rbTrapAdditionalInfo = 73..76 |
rbDiagnosticsHwFaultOff
| .1.3.6.1.4.1.12394.1.2.0.3 | Previously detected hardware fault is fixed.
rbTrapSource = NPU/AU/SU
rbTrapSeverity = Info
rbTrapCategory = Equipment
rbTrapAdditionalInfo = 3..8,23..27. |
rbMonitorAccessOn
| .1.3.6.1.4.1.12394.1.2.0.4 | Device is accessed via LCI or Telnet.
rbTrapSource = NPU/SU
rbTrapSeverity = Info,
rbTrapCategory = Equipment,
rbTrapAdditionalInfo = 140,141,
rbTrapIpAddress |
rbConfigurationChanged
| .1.3.6.1.4.1.12394.1.2.0.41 | Configuration change was detected,
rbTrapSource = NPU/AU/SU/RC/ODU/CHNL/SBSCR/SRVC
rbTrapSeverity = Info,
rbTrapCategory = Equipment
rbTrapAdditionalInfo = 30..33. |
rbParameterSetFailure
| .1.3.6.1.4.1.12394.1.2.0.42 | Configuration change was detected,
rbTrapSource = NPU/AU/SU
rbTrapSeverity = Info,
rbTrapCategory = Equipment
rbTrapSetFailureReason. |
rbMonitorAccessOff
| .1.3.6.1.4.1.12394.1.2.0.5 | LCI or Telnet access was terminated
rbTrapSource = NPU/SU
rbTrapSeverity = Info,
rbTrapCategory = Equipment,
rbTrapAdditionalInfo = 140,141,
rbTrapIpAddress |
rbMbstLicense
| .1.3.6.1.4.1.12394.1.2.0.50 | License Grace Period expiration warning,
rbTrapSource = MicroBST
rbTrapSeverity = Info,
rbTrapCategory = Proc,
rbTrapAdditionalInfo = 184,185. |
rbMbstCPEQuantityExceed
| .1.3.6.1.4.1.12394.1.2.0.51 | Allowed quantity of CPEs exceeded in the actual Mbst,
rbTrapSource = MicroBST
rbTrapSeverity = Info,
rbTrapCategory = Proc,
rbSuMacAddr = Rejected SU Mac |
rbLicenseFileLoadStatus
| .1.3.6.1.4.1.12394.1.2.0.52 | License File Load process status,
rbTrapSource = NPU/MicroBST
rbTrapSeverity = Info,
rbTrapCategory = Proc,
rbTrapAdditionalInfo = 187..191 |
rbAuNetworkEntryStatus
| .1.3.6.1.4.1.12394.1.2.0.6 | AU Network Entry status changed
rbTrapSource = AU
rbTrapSeverity = Info,
rbTrapCategory = Communication,
rbTrapAdditionalInfo = 135-139 |
rbOduCrcErrorOn
| .1.3.6.1.4.1.12394.1.2.0.61 | Obsolete from release 2.5
CRC error in the ODU table was detected,
rbTrapSource = AU
rbTrapSeverity = Warning,
rbTrapCategory = Communication,
rbChannelId = number of channel |
rbOduCrcErrorOff
| .1.3.6.1.4.1.12394.1.2.0.62 | Obsolete from release 2.5
Previously detected CRC error in ODU table terminated,
rbTrapSource = AU
rbTrapSeverity = Info,
rbTrapCategory = Communication,
rbChannelId = number of channel |
rbOduCommErrorOn
| .1.3.6.1.4.1.12394.1.2.0.63 | Error in the communication with the ODU unit was detected,
rbTrapSource = AU
rbTrapSeverity = Minor,
rbTrapCategory = Communication,
rbChannelId = number of channel |
rbOduCommErrorOff
| .1.3.6.1.4.1.12394.1.2.0.64 | Previously detected ODU communication error terminated,
rbTrapSource = AU,
rbTrapSeverity = Info,
rbTrapCategory = Communication,
rbChannelId = number of channel |
rbOduBandMissmatchOn
| .1.3.6.1.4.1.12394.1.2.0.65 | Actual ODU Band does not match configured ODU Band,
rbTrapSource = AU,
rbTrapSeverity = Major,
rbTrapCategory = Communication,
rbChannelId = number of channel |
rbOduBandMissmatchOff
| .1.3.6.1.4.1.12394.1.2.0.66 | Previously detected ODU Band mismatch terminated,
rbTrapSource = AU,
rbTrapSeverity = Info,
rbTrapCategory = Communication,
rbChannelId = number of channel |
rbOduPowerMismatch
| .1.3.6.1.4.1.12394.1.2.0.67 | Actual ODU Max/Min Tx power does not match configured ODU Max/Min Tx power,
rbTrapSource = AU,
rbTrapSeverity = Info,
rbTrapCategory = Communication,
rbChannelId = number of channel |
rbOduFailureOn
| .1.3.6.1.4.1.12394.1.2.0.68 | ODU unit failure was detected,
rbTrapSource = AU
rbTrapSeverity = Major,
rbTrapCategory = Communication,
rbChannelId = number of channel,
rbTrapAdditionalInfo = 225..228 |
rbOduFailureOff
| .1.3.6.1.4.1.12394.1.2.0.69 | Previously detected ODU failure terminated,
rbTrapSource = AU,
rbTrapSeverity = Info,
rbTrapCategory = Communication,
rbChannelId = number of channel |
rbModeConflictOn
| .1.3.6.1.4.1.12394.1.2.0.7 | AU/SU mode conflict was detected
rbTrapSource = AU/SU
rbTrapSeverity = Major,
rbTrapCategory = Communication,
rbTrapAdditionalInfo = 144 .. 149. |
rbModeConflictOff
| .1.3.6.1.4.1.12394.1.2.0.8 | AU/SU mode conflict terminated
rbTrapSource = AU/SU
rbTrapSeverity = Info,
rbTrapCategory = Communication,
rbTrapAdditionalInfo = 144. |
rbSuMaxTxPowerReached
| .1.3.6.1.4.1.12394.1.2.0.81 | SU reached the maximum allowed output power,
rbTrapSource = SU
rbTrapSeverity = Info,
rbTrapCategory = PROC |
rbSuMinTxPowerReached
| .1.3.6.1.4.1.12394.1.2.0.82 | SU reached the minimum allowed output power
rbTrapSource = SU
rbTrapSeverity = Info,
rbTrapCategory = PROC |
rbSuNetworkEntryStatus
| .1.3.6.1.4.1.12394.1.2.0.83 | Status of the SU's network entry.
rbTrapSource = SU,
rbTrapSeverity = Info,
rbTrapCategory = PROC,
rbTrapAdditionalInfo = 132-134 |
rbSuLicense
| .1.3.6.1.4.1.12394.1.2.0.84 | License Grace Period expiration warning,
rbTrapSource = SU
rbTrapSeverity = Info,
rbTrapCategory = Proc,
rbTrapAdditionalInfo = 182-186,
rbLicenseId = Type of License. |
rbSuDuplicateName
| .1.3.6.1.4.1.12394.1.2.0.85 | The SU Name is already in use by another SU.
Services to the SU will be denied until another, unique name is configured for the SU.
rbTrapSource = SU,
rbTrapSeverity = Major,
rbTrapCategory = PROC
rbSuMacAddr = Mac of other SU with same name,
rbSuSysName = previous name,
rbSuSysName = new name |