PowerNet-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
369
Rows
369
Columns
2,817
.1.3.6.1.4.1.318.1.1.1.2.2.12
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsAdvBatteryActualVoltageTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsAdvBatteryActualVoltageTable'
A list of battery table entries. The number of battery frames present in UPS.
Information applicable to
each of the Battery frames.
each of the Battery frames.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
upsAdvBatteryActualVoltageTableIndexmandatory
The Battery Frame identifier. Battery Frame index.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.2.12.1.1 |
||||
|
upsAdvBatteryActualVoltagePolaritymandatory
The selected Battery Voltage Polarity.
0 indicates positive polarity. 1 indicates negative polarity. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.2.2.12.1.2 |
||||
|
upsAdvBatteryFrameActualVoltagemandatory
The actual battery bus voltage in Volts.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.2.12.1.3 |
.1.3.6.1.4.1.318.1.1.1.2.2.13
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsAdvTotalDCCurrentTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsAdvTotalDCCurrentTable'
A list of Battery Frame table entries. The number of entries is given by the value of Number of Battery Frames.
An entry containing information applicable to a
particular Battery Frame.
particular Battery Frame.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
upsAdvTotalDCCurrentTableIndexmandatory
The Battery Frame identifier. Total DC Current
Table Index. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.2.13.1.1 |
||||
|
upsAdvTotalDCCurrentPolaritymandatory
The selected Battery Current Polarity.
0 indicates positive polarity. 1 indicates negative polarity. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.2.2.13.1.2 |
||||
|
upsAdvTotalFrameDCCurrentmandatory
The Total DC Current of battery in Amperes.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.2.13.1.3 |
.1.3.6.1.4.1.318.1.1.1.2.2.14
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsAdvBatteryCurrentTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsAdvBatteryCurrentTable'
A list of Battery Frame table entries. The number of entries is given by number of Battery frames present.
An entry containing information applicable to a
particular battery frame.
particular battery frame.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
upsAdvBatteryCurrentTableIndexmandatory
The Battery Frame identifier. Battery Current
Table Index. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.2.14.1.1 |
||||
|
upsAdvBatteryCurrentIndexmandatory
The battery frame identifier.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.2.14.1.2 |
||||
|
upsAdvBatteryCurrentPolaritymandatory
The selected Battery current polarity.
0 indicates positive polarity. 1 indicates negative polarity |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.2.2.14.1.3 |
||||
|
upsAdvBatteryFrameCurrentmandatory
The Battery current measured in Amperes
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.2.14.1.4 |
.1.3.6.1.4.1.318.1.1.1.2.3.7
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsHighPrecBatteryActualVoltageTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsHighPrecBatteryActualVoltageTable'
A list of Battery frame table entries. The number of entries is given by the number of Battery frames.
An entry containing information applicable to a
particular battery frame.
particular battery frame.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
The Battery Frame identifier. High Precision
Actual Voltage Table Index. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.3.7.1.1 |
||||
|
The selected Battery Voltage polarity.
0 indicates positive polarity. 1 indicates negative polarity. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.2.3.7.1.2 |
||||
|
upsHighPrecBatteryVoltagemandatory
The actual battery bus voltage expressed as tenths of Volts.
If not supported, return -1. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.3.7.1.3 |
.1.3.6.1.4.1.318.1.1.1.2.3.8
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsHighPrecTotalDCCurrentTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsHighPrecTotalDCCurrentTable'
A list of Battery Frame table entries. The number of entries is given by the number of battery frames.
An entry containing information applicable to a
particular battery frame.
particular battery frame.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
upsHighPrecTotalDCCurrentTableIndexmandatory
The Battery Frame identifier.
High precision Total DC Current index. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.3.8.1.1 |
||||
|
upsHighPrecTotalDCCurrentPolaritymandatory
The selected Battery Current polarity.
0 indicates positive polarity. 1 indicates negative polarity. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.2.3.8.1.2 |
||||
|
upsHighPrecTotalDCFrameCurrentmandatory
The total DC current in tenths of Amperes.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.3.8.1.3 |
.1.3.6.1.4.1.318.1.1.1.2.3.9
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsHighPrecBatteryCurrentTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsHighPrecBatteryCurrentTable'
A list of Battery Frame table entries. The number of entries is given by the number of battery frames.
An entry containing information applicable to a
particular battery frame.
particular battery frame.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
upsHighPrecBatteryCurrentTableIndexmandatory
The Battery frame identifier.
Battery Frame index. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.3.9.1.1 |
||||
|
upsHighPrecBatteryCurrentIndexmandatory
The Battery frame identifier.
Battery Index for each frame. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.3.9.1.2 |
||||
|
upsHighPrecBatteryCurrentPolaritymandatory
The selected Battery Current polarity.
0 indicates positive polarity. 1 indicates negative polarity. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.2.3.9.1.3 |
||||
|
upsHighPrecBatteryFrameCurrentmandatory
The Battery current in tenths of Amperes.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.3.9.1.4 |
.1.3.6.1.4.1.318.1.1.1.2.3.10.2
·
1 row entry
·
10 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsHighPrecBatteryPackTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsHighPrecBatteryPackTable'
A list of Battery Pack table entries. The number of entries is given by number of Battery Packs present.
An entry containing information applicable to a
particular battery pack.
particular battery pack.
| Column | Syntax | OID |
|---|---|---|
|
upsHighPrecBatteryPackIndexmandatory
The battery pack identifier.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.1 |
|
upsHighPrecBatteryCartridgeIndexmandatory
The battery cartridge identifier.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.2 |
|
The battery pack firmware revision.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.3 |
|
upsHighPrecBatteryPackSerialNumbermandatory
The battery pack serial number.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.4 |
|
upsHighPrecBatteryPackTemperaturemandatory
The battery pack temperature measured in 10ths of degree Celcius
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.5 |
|
upsHighPrecBatteryPackStatusmandatory
The battery status for the pack only.
bit 0 Disconnected bit 1 Overvoltage bit 2 NeedsReplacement bit 3 OvertemperatureCritical bit 4 Charger bit 5 TemperatureSensor bit 6 BusSoftStart bit 7 OvertemperatureWarning bit 8… |
OctetString | .1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.6 |
|
The battery cartridge health.
bit 0 Battery lifetime okay bit 1 Battery lifetime near end, order replacement cartridge bit 2 Battery lifetime exceeded, replace battery bit 3 Battery lifetime near end acknowledged, order… |
OctetString | .1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.7 |
|
The battery cartridge estimated battery replace date.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.8 |
|
The battery cartridge install date.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.9 |
|
The battery cartridge status.
bit 0 Disconnected bit 1 Overvoltage bit 2 NeedsReplacement bit 3 OvertemperatureCritical bit 4 Charger bit 5 TemperatureSensor bit 6 BusSoftStart bit 7 OvertemperatureWarning bit 8 General… |
OctetString | .1.3.6.1.4.1.318.1.1.1.2.3.10.2.1.10 |
.1.3.6.1.4.1.318.1.1.1.2.3.10.4
·
1 row entry
·
10 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsHighPrecBatteryPackOnlyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsHighPrecBatteryPackOnlyTable'
A list of Battery Pack table entries. The number of entries is given by number of Battery Packs present.
An entry containing information applicable to a
particular battery pack.
particular battery pack.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
upsHighPrecBatteryPackOnlyIndexmandatory
The battery pack identifier.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.3.10.4.1.1 |
|
The battery pack firmware revision.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.2.3.10.4.1.2 |
|
The battery pack serial number.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.2.3.10.4.1.3 |
|
The battery pack temperature measured in 10ths of degree Celcius
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.3.10.4.1.4 |
|
upsHighPrecBatteryPackOnlyStatusmandatory
The battery status for the pack only.
bit 0 Disconnected bit 1 Overvoltage bit 2 NeedsReplacement bit 3 OvertemperatureCritical bit 4 Charger bit 5 TemperatureSensor bit 6 BusSoftStart bit 7 OvertemperatureWarning bit 8… |
OctetString | .1.3.6.1.4.1.318.1.1.1.2.3.10.4.1.5 |
|
upsHighPrecBatteryPackOnlyHealthmandatory
The battery pack health.
bit 0 Battery lifetime okay bit 1 Battery lifetime near end, order replacement pack bit 2 Battery lifetime exceeded, replace battery bit 3 Battery lifetime near end acknowledged, order replaceme… |
OctetString | .1.3.6.1.4.1.318.1.1.1.2.3.10.4.1.6 |
|
The battery pack estimated battery replace date.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.2.3.10.4.1.7 |
|
The battery pack install date.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.1.2.3.10.4.1.8 |
|
The battery pack manufacture date.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.1.2.3.10.4.1.9 |
|
upsHighPrecBatteryPackOnlySKUmandatory
The battery pack SKU.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.1.2.3.10.4.1.10 |
.1.3.6.1.4.1.318.1.1.1.2.5
·
1 row entry
·
16 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsBatteryCabinetTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsBatteryCabinetTable'
Table of battery cabinets
An entry containing information applicable to a
particular battery cabinet.
particular battery cabinet.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
upsBatteryCabinetIndexoptional
The Battery Cabinet identifier. Battery Cabinet
Table Index. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.5.1.1 |
||||||||
|
upsBatteryCabinetLocalIndexoptional
The identification number for the actual battery cabinet in the system.
0 corresponds to the internal batteries 1 and higher corresponds to external battery cabinets |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.5.1.2 |
||||||||
|
The value indicates the wiring configuration, whether the battery is 2-wire or 3-wire.
If it's a 3-wire battery system, the system can have two voltages and currents per cabinet. 1 = 2-wire (a non-split battery) 2 = 3-w… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.2.5.1.3 |
||||||||
|
The battery voltage. For a non-split battery, it is the full voltage.
For a split battery, the value is the voltage for one side/half of the battery |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.5.1.4 |
||||||||
|
The voltage for the second side/half of the battery in a split battery system.
If it is not a split battery, this reports -1 |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.5.1.5 |
||||||||
|
The battery current. For a non-split battery, it is the full current.
For a split battery, the value is the current for one side/half of the battery |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.5.1.6 |
||||||||
|
The current for the second side/half of the battery in a split battery system.
If it is not a split battery, this reports -1 |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.5.1.7 |
||||||||
|
upsBatteryCabinetTemperatureoptional
The measured temperature of the battery cabinet in tenths of degrees Celcius
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.5.1.8 |
||||||||
|
upsBatteryCabinetMaxTemperatureoptional
The highest temperature measured for the battery in the battery cabinet in tenths of degrees Celcius.
If there are multiple sensors in the battery cabinet, it is the selected highest actual value of measured temperature… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.5.1.9 |
||||||||
|
upsBatteryCabinetMinTemperatureoptional
The lowest temperature measured for the battery in the battery cabinet in tenths of degrees Celcius.
If there are multiple sensors in the battery cabinet, it is the selected lowest actual value of measured temperatures.… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.5.1.10 |
||||||||
|
The average temperature for all the battery sensors in the battery cabinet and
for the battery strings, if battery strings are present. Measured in tenths of degrees Celcius. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.5.1.11 |
||||||||
|
upsBatteryCabinetFuseoptional
If the battery cabinet has a common fuse, the status is given by this value.
1 = Fuse open 2 = Fuse OK 3 = Not present |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.2.5.1.12 |
||||||||
|
upsBatteryCabinetBreakeroptional
The value indicates the battery cabinet breaker status. Reports 1 if no breaker is present.
1 = No breaker 2 = Unknown 3 = Breaker open 4 = Breaker closed |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.2.5.1.13 |
||||||||
|
upsBatteryCabinetNumberOfStringsoptional
The number of battery strings in the battery cabinet. The value can be 0,
meaning that no additional information on the battery string is available. 1 and higher means data in the table is provided. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.5.1.14 |
||||||||
|
The number of vertical levels or shelves for battery blocks/modules.
The levels are indexed from the bottom up |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.5.1.15 |
||||||||
|
The number of horizontal positions for battery blocks/modules.
The levels are indexed from left to right |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.5.1.16 |
.1.3.6.1.4.1.318.1.1.1.2.6
·
1 row entry
·
9 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsBatteryCabStringTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsBatteryCabStringTable'
Table of battery strings in the complete battery solution
An entry containing information applicable to a particular battery string
in the battery cabinet.
in the battery cabinet.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
upsBatteryCabStringIndexoptional
The battery cabinet string identifier. Battery cabinet string or halfstring
table index. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.6.1.1 |
||||||
|
upsBatteryCabStringCabReferenceoptional
Reference to the global battery cabinet index where the battery string is placed.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.6.1.2 |
||||||
|
upsBatteryCabStringLocalIndexoptional
Local battery string identification index in the actual battery cabinet (e.g. String 2 in cabinet)
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.6.1.3 |
||||||
|
upsBatteryCabStringCurrentoptional
The current in a battery string or battery halfstring, in tenths of Amps.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.6.1.4 |
||||||
|
Temperature of the battery string or the average of the aggregated temperature of each
battery block/module (in tenths of degrees Celcius). If not available, this variable is set to (-1999). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.6.1.5 |
||||||
|
The actual highest battery temperature measurement for the battery blocks/modules (in tenths of degrees Celcius).
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.6.1.6 |
||||||
|
The actual lowest battery temperature measurement for the battery blocks/modules (in tenths of degrees Celcius).
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.6.1.7 |
||||||
|
upsBatteryCabStringFuseStatusoptional
If the battery string has a common fuse, the status is given by this value.
1 = Fuse open 2 = Fuse OK 3 = Not present |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.2.6.1.8 |
||||||
|
The number of battery blocks/modules in a battery string.
Can be 0, if no data is available in the table of individual battery blocks/cartridges |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.6.1.9 |
.1.3.6.1.4.1.318.1.1.1.2.7
·
1 row entry
·
11 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsBatteryCabBlockTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsBatteryCabBlockTable'
Table of battery blocks/modules in the complete battery solution.
An entry containing information applicable to a particular battery block
in the battery cabinet.
in the battery cabinet.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
upsBatteryCabBlockIndexoptional
The battery cabinet block identifier. Global battery cabinet block
table index. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.7.1.1 |
||||||
|
Reference to the specific global battery string index
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.7.1.2 |
||||||
|
upsBatteryCabBlockLocalIndexoptional
Local battery block/module identification index in the actual battery string (e.g. Battery block 3 in the battery string)
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.7.1.3 |
||||||
|
upsBatteryCabBlockPresentoptional
Value indicates if battery block/module is present in the system.
Typically battery modules are removable and battery blocks are static. Reports notAvailable(3) if data is not available |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.2.7.1.4 |
||||||
|
upsBatteryCabBlockTypeoptional
Text string value, showing the vendor and model of the battery in the battery block/module
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.2.7.1.5 |
||||||
|
upsBatteryCabBlockTemperatureoptional
The temperature for the battery block/module in tenths of degrees Celcius.
If multiple sensors are available it is the highest temperature in the battery block/module |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.7.1.6 |
||||||
|
upsBatteryCabBlockFuseStatusoptional
If the battery module has a fuse, the status is given by this value.
1 = Fuse open 2 = Fuse OK 3 = Not present |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.2.7.1.7 |
||||||
|
upsBatteryCabBlockVoltageoptional
The voltage of the battery block/module
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.7.1.8 |
||||||
|
upsBatteryCabBlockNumberOfCellsoptional
The number of cells in the battery block/module
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.7.1.9 |
||||||
|
The vertical position of the battery block/module in the actual battery cabinet
(e.g. 4, if it is the 4th shelf counting from the bottom) |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.7.1.10 |
||||||
|
The horizontal position of the battery block/module in the actual battery cabinet
(e.g. 3, if it is the 3rd position counting from the left) |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.7.1.11 |
.1.3.6.1.4.1.318.1.1.1.2.8
·
1 row entry
·
5 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsBatteryCabBlockCellTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsBatteryCabBlockCellTable'
Table of battery cells in a battery block/module in the complete battery solution
An entry containing information applicable to a particular battery cell
inside the battery block.
inside the battery block.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
upsBatteryCabBlockCellIndexoptional
The battery block cell identifier. Global battery block cell
table index. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.8.1.1 |
|
upsBatteryCabBlockCellReferenceoptional
Reference to the specific global battery block/module index.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.8.1.2 |
|
upsBatteryCabBlockCellLocalIndexoptional
Local battery block/module identification index in the actual battery block (e.g. battery cell 5 in the battery block)
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.8.1.3 |
|
upsBatteryCabBlockCellVoltageoptional
The measured battery cell voltage
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.8.1.4 |
|
The temperature for the battery cell in tenths of degrees Celcius.
If there is not a temperature sensor for each battery cell, then report -1 for those, which are not present. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.2.8.1.5 |
.1.3.6.1.4.1.318.1.1.1.3.2.10
·
1 row entry
·
7 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsAdvInputStatisticsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsAdvInputStatisticsTable'
A list of input table entries. The number of entries is given by the value of upsPhaseNumInputs.
An entry containing information applicable to a
particular input.
particular input.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
upsAdvInputStatisticsIndexmandatory
The input identifier.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.3.2.10.1.1 |
|
upsAdvInputApparentPowermandatory
The input apparent power(sum of all of the three phases) measured in kVA.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.3.2.10.1.2 |
|
upsAdvInputVoltageTHDmandatory
The input voltage Total Harmonic Distortion in percent.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.3.2.10.1.3 |
|
upsAdvInputBypassVoltageTHDmandatory
The bypass input voltage Total Harmonic Distortion in percent.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.3.2.10.1.4 |
|
upsAdvInputPeakCurrentmandatory
The input peak current in Amperes.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.3.2.10.1.5 |
|
upsAdvInputBypassPeakCurrentmandatory
The bypass input peak current in Amperes.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.3.2.10.1.6 |
|
upsAdvInputActivePowermandatory
The input active power measured in kW.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.3.2.10.1.7 |
.1.3.6.1.4.1.318.1.1.1.4.2.10
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsAdvOutputStatisticsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsAdvOutputStatisticsTable'
A list of input table entries. The number of entries is given by the value of upsPhaseNumOutputs.
An entry containing information applicable to a
particular output.
particular output.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
upsAdvOutputStatisticsIndexmandatory
The output identifier.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.4.2.10.1.1 |
|
upsAdvOutputPeakCurrentmandatory
The output peak current in Amperes.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.4.2.10.1.2 |
|
upsAdvOutputCurrentTHDmandatory
The output current Total Harmonic Distortion in percent.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.4.2.10.1.3 |
|
upsAdvOutputCrestFactormandatory
The output current crest factor expressed in tenths.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.4.2.10.1.4 |
.1.3.6.1.4.1.318.1.1.1.5.1.2
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsBasicConfigDeviceTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsBasicConfigDeviceTable'
A list of devices that are plugged into the UPS. The number of entries is given by the value of upsBasicConfigNumDevices.
The devices plugged in to the UPS.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
deviceIndexmandatory
The index of the device that is plugged into the UPS.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.5.1.2.1.1 |
||||
|
deviceNamemandatory
The name/description of the device plugged into the UPS.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.1.5.1.2.1.2 |
||||
|
vaRatingmandatory
The volt-amp rating of the device plugged into the UPS.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.5.1.2.1.3 |
||||
|
acceptThisDevicemandatory
An entry is added if yes, the entry is deleted if no.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.5.1.2.1.4 |
.1.3.6.1.4.1.318.1.1.1.5.2.13
·
1 row entry
·
2 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsAdvConfigDipSwitchTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsAdvConfigDipSwitchTable'
Current settings of UPS dip switches.
The current setting of one dip switch.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
dipSwitchIndexmandatory
The index of a UPS dip switch.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.5.2.13.1.1 |
||||
|
dipSwitchStatusmandatory
The setting of a UPS dip switch.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.5.2.13.1.2 |
.1.3.6.1.4.1.318.1.1.1.5.2.16
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsAdvConfigAllowedSetTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsAdvConfigAllowedSetTable'
The table listing the allowed values for all discrete configurable UPS variables.
The table entry for a configurable UPS variable.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
apcUpsConfigFieldIndexmandatory
The index to an eeprom field entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.5.2.16.1.1 |
|
apcUpsConfigFieldOIDmandatory
The OID of the current configurable value.
|
ObjectIdentifier | .1.3.6.1.4.1.318.1.1.1.5.2.16.1.2 |
|
apcUpsConfigFieldValueRangemandatory
The discrete set of allowed values of a configurable
register. Individual values are delimited by a comma. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.5.2.16.1.3 |
.1.3.6.1.4.1.318.1.1.1.9.2.2
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsPhaseInputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsPhaseInputTable'
A list of input table entries. The number of entries is given by the value of upsPhaseNumInputs.
An entry containing information applicable to a
particular input.
particular input.
Indexes
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
upsPhaseInputTableIndexmandatory
The input identifier.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.2.2.1.1 |
||||||||||
|
upsPhaseNumInputPhasesmandatory
The number of input phases utilized in this
device. The sum of all the upsPhaseNumInputPhases variable indicates the number of rows in the input phase table. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.2.2.1.2 |
||||||||||
|
upsPhaseInputVoltageOrientationmandatory
The input voltage orientation:
1: unknown for this UPS 2: singlePhase - phase 1 voltage is between Phase 1 and Neutral. 3: splitPhase - phase 1 voltage is between Phase 1 and Neutral; phase 2 voltage is between Phase 2 … |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.9.2.2.1.3 |
||||||||||
|
upsPhaseInputFrequencymandatory
The input frequency in 0.1 Hertz, or -1 if it's unsupported
by this UPS. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.2.2.1.4 |
||||||||||
|
upsPhaseInputTypemandatory
The input type.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.9.2.2.1.5 |
||||||||||
|
upsPhaseInputNamemandatory
A name given to a particular input.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.1.9.2.2.1.6 |
.1.3.6.1.4.1.318.1.1.1.9.2.3
·
1 row entry
·
14 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsPhaseInputPhaseTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsPhaseInputPhaseTable'
A list of input table entries. The number of entries is given by the sum of the upsPhaseNumInputPhases.
An entry containing information applicable to a
particular input phase.
particular input phase.
| Column | Syntax | OID |
|---|---|---|
|
upsPhaseInputPhaseTableIndexmandatory
The input identifier.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.2.3.1.1 |
|
upsPhaseInputPhaseIndexmandatory
The input phase identifier.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.2.3.1.2 |
|
upsPhaseInputVoltagemandatory
The input voltage in VAC, or -1 if it's unsupported
by this UPS. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.2.3.1.3 |
|
upsPhaseInputMaxVoltagemandatory
The maximum input voltage in VAC measured
since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.2.3.1.4 |
|
upsPhaseInputMinVoltagemandatory
The minimum input voltage in VAC measured
since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.2.3.1.5 |
|
upsPhaseInputCurrentmandatory
The input current in 0.1 amperes, or -1 if it's
unsupported by this UPS. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.2.3.1.6 |
|
upsPhaseInputMaxCurrentmandatory
The maximum input current in 0.1 amperes measured
since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.2.3.1.7 |
|
upsPhaseInputMinCurrentmandatory
The minimum input current in 0.1 amperes measured
since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.2.3.1.8 |
|
upsPhaseInputPowermandatory
The input power in Watts, or -1 if it's unsupported
by this UPS. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.2.3.1.9 |
|
upsPhaseInputMaxPowermandatory
The maximum input power in Watts measured
since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.2.3.1.10 |
|
upsPhaseInputMinPowermandatory
The minimum input power in Watts measured
since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.2.3.1.11 |
|
upsPhaseInputApparentPowermandatory
The input apparent power of the UPS in kVA.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.2.3.1.12 |
|
upsPhaseInputPowerFactormandatory
The input power factor measured in hundredth.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.2.3.1.13 |
|
upsPhaseInputVoltagePNmandatory
The input voltage measured across Phase to Neutral in VAC, or -1 if it's unsupported
by this UPS. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.2.3.1.14 |
.1.3.6.1.4.1.318.1.1.1.9.3.2
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsPhaseOutputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsPhaseOutputTable'
A list of output table entries. The number of entries is given by the value of upsOutputNumPhases.
An entry containing information applicable to a
particular output.
particular output.
Indexes
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
upsPhaseOutputTableIndexmandatory
The output identifier.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.3.2.1.1 |
||||||||||
|
upsPhaseNumOutputPhasesmandatory
The number of output phases utilized in this
device. The sum of all the upsPhaseNumOutputPhases variable indicates the number of rows in the output phase table. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.3.2.1.2 |
||||||||||
|
upsPhaseOutputVoltageOrientationmandatory
The output voltage orientation:
1: unknown for this UPS 2: singlePhase - phase 1 voltage is between Phase 1 and Neutral. 3: splitPhase - phase 1 voltage is between Phase 1 and Neutral; phase 2 voltage is between Phase 2… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.9.3.2.1.3 |
||||||||||
|
upsPhaseOutputFrequencymandatory
The output frequency in 0.1 Hertz, or -1 if it's
unsupported by this UPS. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.3.2.1.4 |
.1.3.6.1.4.1.318.1.1.1.9.3.3
·
1 row entry
·
23 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsPhaseOutputPhaseTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsPhaseOutputPhaseTable'
A list of output table entries. The number of entries is given by the sum of the upsPhaseNumOutputPhases.
An entry containing information applicable to a
particular output phase.
particular output phase.
| Column | Syntax | OID |
|---|---|---|
|
upsPhaseOutputPhaseTableIndexmandatory
The output identifier.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.3.3.1.1 |
|
upsPhaseOutputPhaseIndexmandatory
The output phase identifier.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.3.3.1.2 |
|
upsPhaseOutputVoltagemandatory
The output voltage in VAC, or -1 if it's unsupported
by this UPS. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.3.3.1.3 |
|
upsPhaseOutputCurrentmandatory
The output current in 0.1 amperes drawn
by the load on the UPS, or -1 if it's unsupported by this UPS. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.3.3.1.4 |
|
upsPhaseOutputMaxCurrentmandatory
The maximum output current in 0.1 amperes measured
since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.3.3.1.5 |
|
upsPhaseOutputMinCurrentmandatory
The minimum output current in 0.1 amperes measured
since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.3.3.1.6 |
|
upsPhaseOutputLoadmandatory
The output load in VA, or -1 if it's unsupported
by this UPS. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.3.3.1.7 |
|
upsPhaseOutputMaxLoadmandatory
The maximum output load in VA measured
since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.3.3.1.8 |
|
upsPhaseOutputMinLoadmandatory
The minimum output load in VA measured
since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.3.3.1.9 |
|
upsPhaseOutputPercentLoadmandatory
The percentage of the UPS load capacity in VA at
redundancy @ (n + x) presently being used on this output phase, or -1 if it's unsupported by this UPS. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.3.3.1.10 |
|
upsPhaseOutputMaxPercentLoadmandatory
The maximum percentage of the UPS load capacity in
VA measured at redundancy @ (n + x) presently being used on this output phase since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. S… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.3.3.1.11 |
|
upsPhaseOutputMinPercentLoadmandatory
The minimum percentage of the UPS load capacity in
VA measured at redundancy @ (n + x) presently being used on this output phase since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. S… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.3.3.1.12 |
|
upsPhaseOutputPowermandatory
The output power in Watts, or -1 if it's
unsupported by this UPS. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.3.3.1.13 |
|
upsPhaseOutputMaxPowermandatory
The maximum output power in Watts measured
since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.3.3.1.14 |
|
upsPhaseOutputMinPowermandatory
The minimum output power in Watts measured
since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UPS. Sampled every 30 seconds. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.3.3.1.15 |
|
upsPhaseOutputPercentPowermandatory
The percentage of the UPS power capacity in Watts at
redundancy @ (n + x) presently being used on this output phase, or -1 if it's unsupported by this UPS. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.3.3.1.16 |
|
upsPhaseOutputMaxPercentPowermandatory
The maximum percentage of the UPS power capacity
in Watts measured at redundancy @ (n + x) presently being used on this output phase since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UP… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.3.3.1.17 |
|
upsPhaseOutputMinPercentPowermandatory
The maximum percentage of the UPS power capacity
in Watts measured at redundancy @ (n + x) presently being used on this output phase since the last reset (upsPhaseResetMaxMinValues), or -1 if it's unsupported by this UP… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.3.3.1.18 |
|
upsPhaseOutputPowerFactormandatory
The Output power factor of the UPS in hundredth.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.3.3.1.19 |
|
upsPhaseOutputApparentPowermandatory
Apparent power in kVA
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.3.3.1.20 |
|
upsPhaseOutputInverterVoltagemandatory
Output voltage in VAC measured at the output of inverter.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.3.3.1.21 |
|
upsPhaseOutputVoltagePNmandatory
The output voltage measured across Phase to Neutral in VAC, or -1 if it's unsupported
by this UPS. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.9.3.3.1.22 |
|
upsPhaseOutputEnergyUsagemandatory
The output energy usage of the phase in hundredths of kWh.
|
Unsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.318.1.1.1.9.3.3.1.23 |
.1.3.6.1.4.1.318.1.1.1.10.2.2
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsSCGStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsSCGStatusTable'
A list of SCG status table entries. The number of entries is given by the value of upsSCGNumOfGroupMembers.
An entry containing information applicable to a
particular SCG Member.
particular SCG Member.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
upsSCGStatusTableIndexmandatory
The index of a status entry for an active, communicating SCG member.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.10.2.2.1.1 |
||||
|
upsSCGMemberIPmandatory
The IP address of an active, communicating SCG Member.
|
RFC1155-SMIIpAddress Type Constraints: range: 4 |
.1.3.6.1.4.1.318.1.1.1.10.2.2.1.2 |
||||
|
upsSCGACInputStatusmandatory
This OID indicates the AC Input Status of the SCG Member.
acInGood(1) indicates the AC Input is within tolerance. acInBad(2) indicates the AC Input is not within tolerance. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.10.2.2.1.3 |
||||
|
upsSCGACOutputStatusmandatory
This OID indicates the AC Output Status of the SCG Member.
acOutOn(1) indicates the UPS output is providing power to the load. acOutOff(2) indicates the UPS output is not providing power to the load. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.10.2.2.1.4 |
.1.3.6.1.4.1.318.1.1.1.12.1.2
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsOutletGroupStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsOutletGroupStatusTable'
Allows for getting status of the outlet groups. The number of entries is contained in the upsOutletGroupStatusTableSize OID.
The outlet group status to get.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
upsOutletGroupStatusIndexmandatory
The index to the outlet group entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.12.1.2.1.1 |
||||||
|
upsOutletGroupStatusNamemandatory
The name of the outlet group. This OID is provided
for informational purposes only. This value is set by the upsOutletGroupConfigName OID. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.12.1.2.1.2 |
||||||
|
upsOutletGroupStatusGroupStatemandatory
Getting this variable will return the outlet group state. If the outlet
group is on, the upsOutletGroupStatusOn (1) value will be returned. If the outlet group is off, the upsOutletGroupStatusOff (2) value will be retur… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.12.1.2.1.3 |
||||||
|
upsOutletGroupStatusCommandPendingmandatory
Getting this variable will return the command pending
state of the outlet group. If a command is pending on the outlet group, the upsOutletGroupCommandPending (1) value will be returned. If there is not a command pendin… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.12.1.2.1.4 |
||||||
|
upsOutletGroupStatusOutletTypemandatory
Getting this variable will return the type of outlet group.
If present in the system, the main outlet group is 'unswitched' and must be on in order for any of the switched outlet groups to be on. Conversely, if the main… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.12.1.2.1.5 |
||||||
|
upsOutletGroupStatusGroupFullStatemandatory
An ASCII string containing the 32 flags representing the
current state(s) of the outlet group. If the Network Card is unable to determine the state of the outlet group, this variable is set to 'UNKNOWN'. … |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.12.1.2.1.6 |
.1.3.6.1.4.1.318.1.1.1.12.2.2
·
1 row entry
·
14 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsOutletGroupConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsOutletGroupConfigTable'
The list of outlet groups to configure. The number of entries is defined by the upsOutletGroupConfigTableSize OID.
The outlet groups to configure.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
upsOutletGroupConfigIndexmandatory
The index to the outlet group entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.12.2.2.1.1 |
||||
|
upsOutletGroupConfigNamemandatory
The name of the outlet group.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.1.12.2.2.1.2 |
||||
|
upsOutletGroupConfigPowerOnDelaymandatory
The amount of time (seconds) the outlet group will delay
powering on when the delayed on, reboot, or shutdown command is applied. Allowed values vary by UPS model. The value of -1 is used for Never if supported by the U… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.12.2.2.1.3 |
||||
|
upsOutletGroupConfigPowerOffDelaymandatory
The amount of time (seconds) the outlet group will delay
powering off when the delayed off, reboot, or shutdown command is applied. Allowed values vary by UPS model. The value of -1 is used for Never if supported by the… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.12.2.2.1.4 |
||||
|
upsOutletGroupConfigRebootDurationmandatory
During a reboot sequence, power is turned off and then
back on. This OID defines the amount of time to wait (seconds) after turning the power off, at the start of the sequence, before initiating the power on sequence. A… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.12.2.2.1.5 |
||||
|
upsOutletGroupConfigMinReturnRuntimemandatory
In an Outlet Group shutdown sequence, the Outlet Group cycles
power off then on. This OID defines the minimum amount of UPS runtime (seconds) that is required in order to power the Outlet Group on. Allowed values vary b… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.12.2.2.1.6 |
||||
|
upsOutletGroupConfigOutletTypemandatory
Getting this variable will return the type of outlet group.
If present in the system, the main outlet group is 'unswitched' and must be on in order for any of the switched outlet groups to be on. Conversely, if the main… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.12.2.2.1.7 |
||||
|
Configures whether the outlet group's off delay setting
(upsOutletGroupConfigPowerOffDelay) will be used in a load shedding situation, where applicable. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.12.2.2.1.8 |
||||
|
Configures whether the outlet group will automatically restart
after a load shedding situation, where applicable. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.12.2.2.1.9 |
||||
|
Configures whether the outlet group will load shed (turn off)
after the UPS device's time on battery has exceeded the upsOutletGroupConfigLoadShedTimeOnBattery OID setting. The settings for upsOutletGroupConfigLoadShedC… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.12.2.2.1.10 |
||||
|
Configures whether the outlet group will load shed (turn off)
when the UPS is on battery and the remaining runtime is less than the upsOutletGroupConfigLoadShedRuntimeRemaining OID setting. The settings for upsOutletGro… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.12.2.2.1.11 |
||||
|
Configures whether the outlet group will load shed (turn off)
when the UPS is in an overload condition. The setting for upsOutletGroupConfigLoadShedControlSkipOffDelay is valid for this load shed condition. Returns -1 i… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.12.2.2.1.12 |
||||
|
When the UPS has been on battery for more time than this
value, the outlet group will turn off if this condition is enabled by the upsOutletGroupConfigLoadShedControlTimeOnBattery OID. Allowed values vary by UPS model. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.12.2.2.1.13 |
||||
|
When the runtime remaining is less than this value, the outlet
group will turn off if this condition is enabled by the upsOutletGroupConfigLoadShedControlRuntimeRemaining OID. Allowed values vary by UPS model. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.12.2.2.1.14 |
.1.3.6.1.4.1.318.1.1.1.12.3.2
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsOutletGroupControlTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsOutletGroupControlTable'
Allows for control of individual outlet groups. The number of entries is contained in the upsOutletGroupControlTableSize OID.
The outlet group to control.
Indexes
| Column | Syntax | OID | ||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
upsOutletGroupControlIndexmandatory
The index to the outlet group entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.12.3.2.1.1 |
||||||||||||||||||||
|
upsOutletGroupControlNamemandatory
The name of the outlet group. This OID is provided
for informational purposes only. This value is set by the upsOutletGroupConfigName OID. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.12.3.2.1.2 |
||||||||||||||||||||
|
upsOutletGroupControlCommandmandatory
Getting this variable will return the outlet group state. If the outlet
group is on, the upsOutletGroupImmediateOn (1) value will be returned. If the outlet group is off, the upsOutletGroupImmediateOff (2) value will be… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.12.3.2.1.3 |
||||||||||||||||||||
|
upsOutletGroupControlOutletTypemandatory
Getting this variable will return the type of outlet group.
If present in the system, the main outlet group is 'unswitched' and must be on in order for any of the switched outlet groups to be on. Conversely, if the main… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.12.3.2.1.4 |
.1.3.6.1.4.1.318.1.1.1.13.1.2
·
1 row entry
·
10 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsDiagIMTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsDiagIMTable'
Allows for diagnostics of individual Intelligence Modules. The number of entries is contained in the upsDiagIMTableSize OID.
The diagnostics and information of an Intelligence Module.
Indexes
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
upsDiagIMIndexmandatory
The index to the Intelligence Module entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.1.2.1.1 |
||||||||||||||
|
upsDiagIMTypemandatory
The type of the Intelligence Module.
imUnknown(1) indicates the IM type is unknown. imMIM(2) indicates the IM type is a Main Intelligence Module. imRIM(3) indicates the IM type is Redundant Intelligence Module. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.13.1.2.1.2 |
||||||||||||||
|
upsDiagIMStatusmandatory
The status of the Intelligence Module.
unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the … |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.13.1.2.1.3 |
||||||||||||||
|
upsDiagIMFirmwareRevmandatory
The firmware revision of the Intelligence Module.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.1.2.1.4 |
||||||||||||||
|
upsDiagIMSlaveFirmwareRevmandatory
The slave firmware revision of the Intelligence Module.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.1.2.1.5 |
||||||||||||||
|
upsDiagIMHardwareRevmandatory
The hardware revision of the Intelligence Module.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.1.2.1.6 |
||||||||||||||
|
upsDiagIMSerialNummandatory
The serial number of the Intelligence Module.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.1.2.1.7 |
||||||||||||||
|
upsDiagIMManufactureDatemandatory
The manufacture date of the Intelligence Module.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.1.2.1.8 |
||||||||||||||
|
upsDiagIMInControlmandatory
The Intelligence Module state.
activeInControl(1) indicates the IM is active and in control. passive(2) indicates the IM is in passive state. unknown(3) indicates the IM is in unknown state. fault(4) indicates the IM is… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.13.1.2.1.9 |
||||||||||||||
|
upsDiagIMSKUmandatory
The SKU of the Intelligence Module.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.1.2.1.10 |
.1.3.6.1.4.1.318.1.1.1.13.2.2
·
1 row entry
·
11 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsDiagPMTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsDiagPMTable'
Allows for diagnostics of Individual Power modules. The number of entries is contained in the upsDiagPMTableSize OID.
The diagnostics of a Power Module.
Indexes
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
upsDiagPMIndexmandatory
The index to the Power Module entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.2.2.1.1 |
||||||||||||||
|
upsDiagPMStatusmandatory
The status of the Power Module.
unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device … |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.13.2.2.1.2 |
||||||||||||||
|
upsDiagPMFirmwareRevmandatory
The firmware revision of the Power Module.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.2.2.1.3 |
||||||||||||||
|
upsDiagPMHardwareRevmandatory
The hardware revision of the Power Module.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.2.2.1.4 |
||||||||||||||
|
upsDiagPMSerialNummandatory
The serial number of the Power Module.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.2.2.1.5 |
||||||||||||||
|
upsDiagPMManufactureDatemandatory
The manufacture date of the Power Module.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.2.2.1.6 |
||||||||||||||
|
upsDiagPMModelNummandatory
The model number of the Power Module.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.2.2.1.7 |
||||||||||||||
|
upsDiagPMRatingoptional
The power rating (in kVA) of the Power Module
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.2.2.1.8 |
||||||||||||||
|
upsDiagPMSKUoptional
The SKU of the Power Module
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.2.2.1.9 |
||||||||||||||
|
upsDiagPMAverageFanSpeedoptional
The average fan speed of the working fans in the Power Module in revolutions per minute (RPM).
Returns (-1) if not set. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.2.2.1.10 |
||||||||||||||
|
upsDiagPMAmbientTemperatureoptional
The ambient temperature inside the Power Module in tenths of degrees celsius.
If not available, this variable is set to (-1999). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.2.2.1.11 |
.1.3.6.1.4.1.318.1.1.1.13.2.3
·
1 row entry
·
7 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsDiagPMLifetimeInfoTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsDiagPMLifetimeInfoTable'
Allows for diagnostics of individual power module's lifetime information. The number of entries is contained in the upsDiagPMTableSize OID.
The diagnostics of a Power Module lifetime information.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
upsDiagPMLifetimeInfoIndexmandatory
The index to the Power Module lifetime information entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.2.3.1.1 |
||||||||
|
upsDiagPMLifetimeStatusmandatory
The status of the Power Module lifetime information.
ok(1) indicates the device lifetime status is OK. nearEnd(2) indicates the device lifetime status is near end. exceeded(3) indicates the device lifetime status is exc… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.13.2.3.1.2 |
||||||||
|
upsDiagPMEstmtdLifetimeRmngmandatory
Displays the time remaining for the module before it should be replaced.
Measured in months. This value is set when you originally install the module. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.2.3.1.3 |
||||||||
|
upsDiagPMEstmtdLifetimeRmngPctmandatory
Displays the percentage of the total lifetime remaining for the module
before it should be replaced. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.2.3.1.4 |
||||||||
|
upsDiagPMFanLifetimeStatusmandatory
The status of the Power Module Fan lifetime information.
ok(1) indicates the device lifetime status is OK. nearEnd(2) indicates the device lifetime status is near end. exceeded(3) indicates the device lifetime status is… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.13.2.3.1.5 |
||||||||
|
upsDiagPMFanEstmtdLifetimeRmngmandatory
Displays the time remaining, measured in months, before the module's
fan should be replaced. It is reset by the field service engineer when a new fan is installed. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.2.3.1.6 |
||||||||
|
upsDiagPMFanEstmtdLifetimeRmngPctmandatory
Displays the percentage of the total lifetime remaining
before the module's fan should be replaced. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.2.3.1.7 |
.1.3.6.1.4.1.318.1.1.1.13.2.5
·
1 row entry
·
5 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsDiagPMEnclDoorFltrTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsDiagPMEnclDoorFltrTable'
Allows for the diagnostics of individual power module enclosure door filters. The number of entries is contained in the upsDiagPMEnclDoorFltrTableSize OID.
Power module door filter diagnostics info.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
upsDiagPMEnclIndexmandatory
The index to the power module enclosure entry.
Enclosure 0 indicates the Power enclosure 1. Enclosure 1 indicates the Power enclosure 2. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.2.5.1.1 |
||||||||
|
upsDiagPMEnclDoorFltrLifetimemandatory
Door filter replacement time interval, based on the installation enivironment.
heavyFiltration15days (1) indicates door filter needs to be replaced within 15 days. normalFiltration30days (2) indicates door filter needs … |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.13.2.5.1.2 |
||||||||
|
upsDiagPMEnclDoorFltrStatusmandatory
Indicates the current status of the door filter.
ok(1) indicates the device lifetime status is OK. nearEnd(2) indicates the device lifetime status is near end. exceeded(3) indicates the device lifetime status is exceede… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.13.2.5.1.3 |
||||||||
|
Displays the time remaining, measured in days, before the module door filter should be replaced.
This value is set when you originally install the module. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.2.5.1.4 |
||||||||
|
Displays the percentage of the total lifetime remaining for the module
door filter before it should be replaced. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.2.5.1.5 |
.1.3.6.1.4.1.318.1.1.1.13.3.2
·
1 row entry
·
11 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsDiagBatteryTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsDiagBatteryTable'
Allows for diagnostics of individual batteries. The number of entries is contained in the upsDiagBattTableSize OID.
The diagnostics of a battery.
Indexes
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
upsDiagBatteryFrameIndexmandatory
The index to the battery frame entry.
Frame 0 indicates the Main frame. Extended Run (XR) frames start from index 1. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.3.2.1.1 |
||||||||||||||
|
upsDiagBatteryIndexmandatory
The index to the battery entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.3.2.1.2 |
||||||||||||||
|
upsDiagBatteryStatusmandatory
The status of the battery.
unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. ok(3) indicates the battery status is OK. failed(4) indicates the battery status is fa… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.13.3.2.1.3 |
||||||||||||||
|
upsDiagBatterySerialNumbermandatory
The serial number of the battery.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.3.2.1.4 |
||||||||||||||
|
upsDiagBatteryFirmwareRevmandatory
The firmware revision of the battery.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.3.2.1.5 |
||||||||||||||
|
upsDiagBatteryManufactureDatemandatory
The manufacture date of the battery.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.3.2.1.6 |
||||||||||||||
|
upsDiagBatteryTypemandatory
The battery type or rating for the battery.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.3.2.1.7 |
||||||||||||||
|
upsDiagBatteryFramePresentmandatory
The battery frame/cabinet status.
0 indicates frame/cabinet is not present. 1 indicates frame/cabinet is present. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.13.3.2.1.8 |
||||||||||||||
|
upsDiagBatteryFrameTemperaturemandatory
The battery frame/cabinet temperature in tenths of degrees celsius.
If the frame/cabinet is not present, this variable is set to (-1). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.3.2.1.9 |
||||||||||||||
|
upsDiagBatterySKUmandatory
The SKU of the battery.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.3.2.1.10 |
||||||||||||||
|
upsDiagBatteryHealthmandatory
The battery health.
bit 0 Battery lifetime okay bit 1 Battery lifetime near end, order replacement module bit 2 Battery lifetime exceeded, replace battery bit 3 Battery lifetime near end acknowledged, order replacement … |
OctetString | .1.3.6.1.4.1.318.1.1.1.13.3.2.1.11 |
.1.3.6.1.4.1.318.1.1.1.13.3.4
·
1 row entry
·
5 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsDiagBatteryFrameTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsDiagBatteryFrameTable'
Allows for diagnostics of individual battery frame. The number of entries is contained in the upsDiagBatteryFrameTableSize OID.
The diagnostics of a battery frame.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
upsDiagBatteryFrameTableIndexmandatory
The index to the battery frame entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.3.4.1.1 |
|
upsDiagBatteryModuleStatusPerFramemandatory
An ASCII string containing the 64 flags representing
the status of battery modules. 1 indicates battery module installed, 0 indicates battery module not installed. The flags are numbered from 1 to 64, and… |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.3.4.1.2 |
|
upsDiagBatteryPositiveVoltagemandatory
The battery positive voltage, in Volts.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.3.4.1.3 |
|
upsDiagBatteryNegativeVoltagemandatory
The battery negative voltage, in Volts.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.3.4.1.4 |
|
upsDiagBatteryTemperaturemandatory
The battery frame/cabinet temperature in tenths of degrees celsius.
If the frame/cabinet is not present, this variable is set to (-1). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.3.4.1.5 |
.1.3.6.1.4.1.318.1.1.1.13.4.2
·
1 row entry
·
7 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsDiagSubSysFrameTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsDiagSubSysFrameTable'
Allows for diagnostics of individual XR Frames.
The diagnostics of an XR Frame.
Indexes
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
upsDiagSubSysFrameIndexmandatory
The frame index entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.4.2.1.1 |
||||||||||
|
upsDiagSubSysFrameTypemandatory
The type of Frame.
unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. frameTypeMain(3) indicates the frame type is the Main Frame. frameTypeXR(4) indicates the fram… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.13.4.2.1.2 |
||||||||||
|
upsDiagSubSysFrameFirmwareRevmandatory
The firmware revision of the frame.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.2.1.3 |
||||||||||
|
upsDiagSubSysFrameHardwareRevmandatory
The hardware revision of the frame.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.2.1.4 |
||||||||||
|
upsDiagSubSysFrameSerialNummandatory
The serial number of the frame.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.2.1.5 |
||||||||||
|
upsDiagSubSysFrameManufactureDatemandatory
The manufacture date of the frame.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.2.1.6 |
||||||||||
|
upsDiagSubSysFrameSKUmandatory
The SKU of the frame.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.2.1.7 |
.1.3.6.1.4.1.318.1.1.1.13.4.4
·
1 row entry
·
10 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsDiagSubSysIntBypSwitchTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsDiagSubSysIntBypSwitchTable'
Allows for diagnostics of the Internal Bypass Switch.
The diagnostics of the Internal Bypass Switch.
Indexes
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
upsDiagSubSysIntBypSwitchFrameIndexmandatory
The frame index entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.4.4.1.1 |
||||||||||||||
|
upsDiagSubSysIntBypSwitchIndexmandatory
The Internal Bypass Switch index entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.4.4.1.2 |
||||||||||||||
|
upsDiagSubSysIntBypSwitchStatusmandatory
The Internal Bypass Switch status.
unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the devi… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.13.4.4.1.3 |
||||||||||||||
|
upsDiagSubSysIntBypSwitchFirmwareRevmandatory
The firmware revision of the Internal Bypass Switch.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.4.1.4 |
||||||||||||||
|
upsDiagSubSysIntBypSwitchHardwareRevmandatory
The hardware revision of the Internal Bypass Switch.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.4.1.5 |
||||||||||||||
|
upsDiagSubSysIntBypSwitchSerialNummandatory
The serial number of the Internal Bypass Switch.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.4.1.6 |
||||||||||||||
|
The manufacture date of the Internal Bypass Switch.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.4.1.7 |
||||||||||||||
|
upsDiagSubSysIntBypSwitchModelNummandatory
The model number of the Internal Bypass Switch.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.4.1.8 |
||||||||||||||
|
upsDiagSubSysIntBypFanSpeedoptional
The average fan speed of the working fans in the Internal Bypass Switch in revolutions per minute (RPM).
Returns (-1) if not set. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.4.4.1.9 |
||||||||||||||
|
The ambient temperature in tenths of degrees celcius inside the Internal Bypass Switch.
If not available, this variable is set to (-1999). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.4.4.1.10 |
.1.3.6.1.4.1.318.1.1.1.13.4.6
·
1 row entry
·
7 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsDiagSubSysBattMonitorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsDiagSubSysBattMonitorTable'
Allows for diagnostics of the Battery Monitor Board.
The diagnostics of the Battery Monitor Board.
Indexes
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
upsDiagSubSysBattMonitorFrameIndexmandatory
The frame index entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.4.6.1.1 |
||||||||||||||
|
upsDiagSubSysBattMonitorIndexmandatory
The index of the Battery Monitor Board.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.4.6.1.2 |
||||||||||||||
|
upsDiagSubSysBattMonitorStatusmandatory
The status of the Battery Monitor Board.
unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates th… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.13.4.6.1.3 |
||||||||||||||
|
upsDiagSubSysBattMonitorFirmwareRevmandatory
The firmware revision of the Battery Monitor Board.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.6.1.4 |
||||||||||||||
|
upsDiagSubSysBattMonitorHardwareRevmandatory
The hardware revision of the Battery Monitor Board.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.6.1.5 |
||||||||||||||
|
upsDiagSubSysBattMonitorSerialNummandatory
The serial number of the Battery Monitor Board.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.6.1.6 |
||||||||||||||
|
The date of the manufacture for the Battery Monitor Board.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.6.1.7 |
.1.3.6.1.4.1.318.1.1.1.13.4.8
·
1 row entry
·
8 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsDiagSubSysExternalSwitchGearTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsDiagSubSysExternalSwitchGearTable'
Allows for diagnostics of the individual External Switch Gear.
The diagnostics of an individual External Switch Gear.
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
The frame index entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.4.8.1.1 |
||||||||||||||
|
upsDiagSubSysExternalSwitchGearIndexmandatory
The index of the External Switch Gear.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.4.8.1.2 |
||||||||||||||
|
The status of the External Switch Gear.
unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.13.4.8.1.3 |
||||||||||||||
|
The firmware revision of the External Switch Gear monitor card.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.8.1.4 |
||||||||||||||
|
The hardware revision of the External Switch Gear monitor card.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.8.1.5 |
||||||||||||||
|
The serial number of the External Switch Gear monitor card.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.8.1.6 |
||||||||||||||
|
The date of the manufacture for the External Switch Gear monitor card.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.8.1.7 |
||||||||||||||
|
The temperature of the air around the External Switch
Gear monitor card in tenths of degrees Celsius. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.4.8.1.8 |
.1.3.6.1.4.1.318.1.1.1.13.4.10
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsDiagSubSysDisplayInterfaceCardTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsDiagSubSysDisplayInterfaceCardTable'
Allows for diagnostics of individual Display Interface Cards.
The diagnostics of a Display Interface Card.
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
The frame index entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.4.10.1.1 |
||||||||||||||
|
The index of the Display Interface Card.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.4.10.1.2 |
||||||||||||||
|
The status of the Display Interface Card.
unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates t… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.13.4.10.1.3 |
.1.3.6.1.4.1.318.1.1.1.13.4.12
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsDiagSubSysDCCircuitBreakerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsDiagSubSysDCCircuitBreakerTable'
Allows for diagnostics of individual DC Circuit Breakers.
The diagnostics of a DC Circuit Breaker.
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
The frame index entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.4.12.1.1 |
||||||||
|
upsDiagSubSysDCCircuitBreakerIndexmandatory
The index of the DC Circuit Breaker.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.4.12.1.2 |
||||||||
|
upsDiagSubSysDCCircuitBreakerStatusmandatory
The status of the DC Circuit Breaker.
unknown(1) indicates the circuit breaker status is unknown. notInstalled(2) indicates the circuit breaker is not installed. opened(3) indicates the circuit breaker is opened. closed… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.13.4.12.1.3 |
.1.3.6.1.4.1.318.1.1.1.13.4.14
·
1 row entry
·
7 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsDiagSubSysSystemPowerSupplyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsDiagSubSysSystemPowerSupplyTable'
Allows for diagnostics of individual System Power Supplies.
The diagnostics of a System Power Supply.
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
The frame index entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.4.14.1.1 |
||||||||||||||
|
upsDiagSubSysSystemPowerSupplyIndexmandatory
The index of a System Power Supply.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.4.14.1.2 |
||||||||||||||
|
upsDiagSubSysSystemPowerSupplyStatusmandatory
The status of the System Power Supply.
unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the … |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.13.4.14.1.3 |
||||||||||||||
|
The firmware revision of the System Power Supply monitor card.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.14.1.4 |
||||||||||||||
|
The hardware revision of the System Power Supply monitor card.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.14.1.5 |
||||||||||||||
|
The serial number of the System Power Supply monitor card.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.14.1.6 |
||||||||||||||
|
The date of the manufacture for the System Power Supply monitor card.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.14.1.7 |
.1.3.6.1.4.1.318.1.1.1.13.4.16
·
1 row entry
·
5 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsDiagSubSysXRCommunicationCardTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsDiagSubSysXRCommunicationCardTable'
Allows for diagnostics of individual XR Communication Cards.
The diagnostics of an XR Communication Card.
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
The frame index entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.4.16.1.1 |
||||||||||||||
|
The index of an XR Communication Card.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.4.16.1.2 |
||||||||||||||
|
The status of the XR Communication Card.
unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates th… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.13.4.16.1.3 |
||||||||||||||
|
The firmware revision of the XR Communication card.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.16.1.4 |
||||||||||||||
|
The serial number of the XR Communication card.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.16.1.5 |
.1.3.6.1.4.1.318.1.1.1.13.4.18
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsDiagSubSysExternalPowerFrameBoardTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsDiagSubSysExternalPowerFrameBoardTable'
Allows for diagnostics of individual External Power Frame Boards.
The diagnostics of an External Power Frame Board.
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
The frame index entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.4.18.1.1 |
||||||||||||||
|
The index of an External Power Frame Board.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.4.18.1.2 |
||||||||||||||
|
The status of the External Power Frame Board.
unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicat… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.13.4.18.1.3 |
.1.3.6.1.4.1.318.1.1.1.13.4.20
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsDiagSubSysChargerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsDiagSubSysChargerTable'
Allows for diagnostics of individual chargers.
The diagnostics of a charger.
Indexes
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
upsDiagSubSysChargerFrameIndexmandatory
The frame index entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.4.20.1.1 |
||||||||||||||
|
upsDiagSubSysChargerIndexmandatory
The index of a charger.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.4.20.1.2 |
||||||||||||||
|
upsDiagSubSysChargerStatusmandatory
The status of the Charger.
unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device statu… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.13.4.20.1.3 |
.1.3.6.1.4.1.318.1.1.1.13.4.22
·
1 row entry
·
7 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsDiagSubSysInverterTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsDiagSubSysInverterTable'
Allows for diagnostics of individual Inverters.
The diagnostics of an Inverter.
Indexes
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
upsDiagSubSysInverterFrameIndexmandatory
The frame index entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.4.22.1.1 |
||||||||||||||
|
upsDiagSubSysInverterIndexmandatory
The index of an Inverter.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.4.22.1.2 |
||||||||||||||
|
upsDiagSubSysInverterStatusmandatory
The status of the Inverter.
unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the device stat… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.13.4.22.1.3 |
||||||||||||||
|
upsDiagSubSysInverterFirmwareRevmandatory
The firmware revision of the Inverter monitor.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.22.1.4 |
||||||||||||||
|
upsDiagSubSysInverterHardwareRevmandatory
The hardware revision of the Inverter monitor.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.22.1.5 |
||||||||||||||
|
upsDiagSubSysInverterSerialNummandatory
The serial number of the Inverter monitor.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.22.1.6 |
||||||||||||||
|
upsDiagSubSysInverterManufactureDatemandatory
The date of manufacture for the Inverter monitor.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.22.1.7 |
.1.3.6.1.4.1.318.1.1.1.13.4.24
·
1 row entry
·
7 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsDiagSubSysPowerFactorCorrectionTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsDiagSubSysPowerFactorCorrectionTable'
Allows for diagnostics of individual PowerFactorCorrections.
The diagnostics of a Power Factor Correction.
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
The frame index entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.4.24.1.1 |
||||||||||||||
|
The index of a Power Factor Correction.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.4.24.1.2 |
||||||||||||||
|
The status of the Power Factor Correction.
unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates … |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.13.4.24.1.3 |
||||||||||||||
|
The firmware revision of the Power Factor Correction monitor.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.24.1.4 |
||||||||||||||
|
The hardware revision of the Power Factor Correction monitor.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.24.1.5 |
||||||||||||||
|
The serial number of the Power Factor Correction monitor.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.24.1.6 |
||||||||||||||
|
The date of the manufacture for the Power Factor Correction monitor.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.24.1.7 |
.1.3.6.1.4.1.318.1.1.1.13.4.26
·
1 row entry
·
7 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsDiagSubSysNetworkComCardTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsDiagSubSysNetworkComCardTable'
Allows for getting diagnostics information of an individual Network Communication Card.
The diagnostics of a Network Communication Card.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
upsDiagSubSysNetworkComCardIndexmandatory
The UPS network and display interface communication card index entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.4.26.1.1 |
|
A character string identifying the model number of the UPS network and display interface communication card.
This value is set at the factory. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.26.1.2 |
|
A character string identifying the serial number of the UPS network and display interface communication card.
This value is set at the factory. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.26.1.3 |
|
The date when the UPS network and display interface communication card was manufactured in mm/dd/yyyy format.
This value is set at the factory. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.26.1.4 |
|
The hardware revision of the UPS network and display interface communication card.
This value is set at the factory. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.26.1.5 |
|
An ID string identifying the application firmware revision of the
UPS network and display interface communication card. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.26.1.6 |
|
An ID string identifying the application operating system firmware revision of the
UPS network and display interface communication card. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.26.1.7 |
.1.3.6.1.4.1.318.1.1.1.13.4.28
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsDiagSubSysUsrSuppBattMonitorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsDiagSubSysUsrSuppBattMonitorTable'
Allows for diagnostics of the user supplied Battery Monitor Board.
The diagnostics of the user supplied Battery Monitor Board.
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
upsDiagSubSysUsrSuppBattMonitorIndexmandatory
The index of the user supplied Battery Monitor Board.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.4.28.1.1 |
||||||||||||||
|
The status of the user supplied Battery Monitor Board.
unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.13.4.28.1.2 |
||||||||||||||
|
The firmware revision of the user supplied Battery Monitor Board.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.28.1.3 |
||||||||||||||
|
The hardware revision of the user supplied
Battery Monitor Board. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.28.1.4 |
||||||||||||||
|
The serial number of the user supplied
Battery Monitor Board. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.28.1.5 |
||||||||||||||
|
The temperature of the air around the user supplied
Battery Monitor Board in tenths of degrees Celsius. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.4.28.1.6 |
.1.3.6.1.4.1.318.1.1.1.13.4.31
·
1 row entry
·
2 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsDiagSubSysPSUTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsDiagSubSysPSUTable'
Allows for diagnostics of individual Power Supply Units. The number of entries is contained in the upsDiagSubSysPSUTableSize OID.
The diagnostics information of a Power Supply Unit.
Indexes
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
upsDiagSubSysPSUIndexmandatory
The index to the Power Supply Unit entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.4.31.1.1 |
||||||||||||||
|
upsDiagSubSysPSUStatusmandatory
The status of the Power Supply Unit.
unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the de… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.13.4.31.1.2 |
.1.3.6.1.4.1.318.1.1.1.13.4.33
·
1 row entry
·
5 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsDiagSubSysIDRCTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsDiagSubSysIDRCTable'
Allows for diagnostics of the ID and Relay Controller Card.
The diagnostics of the ID and Relay Controller Card.
Indexes
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
upsDiagSubSysIDRCIndexmandatory
The index of the ID and Relay Controller Card.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.4.33.1.1 |
||||||||||||||
|
upsDiagSubSysIDRCStatusmandatory
The status of the ID and Relay Controller Card.
unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indic… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.13.4.33.1.2 |
||||||||||||||
|
upsDiagSubSysIDRCFirmwareRevmandatory
The firmware revision of the ID and Relay Controller Card.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.33.1.3 |
||||||||||||||
|
upsDiagSubSysIDRCHardwareRevmandatory
The hardware revision of the ID and Relay Controller Card.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.33.1.4 |
||||||||||||||
|
upsDiagSubSysIDRCSerialNummandatory
The serial number of the ID
and Relay Controller Card. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.4.33.1.5 |
.1.3.6.1.4.1.318.1.1.1.13.4.36
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsDiagSubSysBackfeedContactorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsDiagSubSysBackfeedContactorTable'
Backfeed protection contactor table.
A list of backfeed protection contactors.
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
upsDiagSubSysbackfeedContactorIndexmandatory
The index of the backfeed protection contactor.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.4.36.1.1 |
||||||
|
upsDiagSubSysbackfeedContactorNamemandatory
The name of the backfeed protection contactor.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.1.13.4.36.1.2 |
||||||
|
upsDiagSubSysbackfeedContactorTypemandatory
Indicates the backfeed protection contactor types available in the UPS system.
If the UPS is unable to find any attached contactors, this variable is set to unknown(1). |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.13.4.36.1.3 |
||||||
|
upsDiagSubSysbackfeedContactorStatusmandatory
The status of backfeed protection contactor.
unknown(1) indicates the contactor status is unknown. opened (2) indicates the contactor is opened. closed (3) indicates the contactor is closed. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.13.4.36.1.4 |
.1.3.6.1.4.1.318.1.1.1.13.4.38
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsDiagSubSysIntBypSwitchFanLifetimeInfoTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsDiagSubSysIntBypSwitchFanLifetimeInfoTable'
Allows for diagnostics of the Internal Bypass Switch life time infomation.
The diagnostics of the Internal Bypass Switch.
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
The index to the Internal Bypass Switch Fan liftime information entry
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.4.38.1.1 |
||||||||
|
The status of the Internal Bypass Switch Fan lifetime information.
ok(1) indicates the device lifetime status is OK. nearEnd(2) indicates the device lifetime status is near end. exceeded(3) indicates the device lifetime… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.13.4.38.1.2 |
||||||||
|
Displays the time remaining for the module before it should be replaced.
Measured in months. This value is set when you originally install the module. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.4.38.1.3 |
||||||||
|
Displays the percentage of the total lifetime remaining for the module
before it should be replaced. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.4.38.1.4 |
.1.3.6.1.4.1.318.1.1.1.13.5.1.7
·
1 row entry
·
5 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsDiagSwitchGearBreakerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsDiagSwitchGearBreakerTable'
Switchgear breaker table.
A list of switchgear breakers.
Indexes
| Column | Syntax | OID | ||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
switchgearBreakerIndexmandatory
The index of the switchgear breaker.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.5.1.7.1.1 |
||||||||||||||||||||
|
switchgearBreakerPresentmandatory
Indicates if the switchgear breaker is present.
notPresent(1) indicates that the breaker is not present. present(2) indicates that the breaker is present. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.13.5.1.7.1.2 |
||||||||||||||||||||
|
switchgearBreakerNamemandatory
The name of the switchgear breaker.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.1.13.5.1.7.1.3 |
||||||||||||||||||||
|
switchgearBreakerTypemandatory
Indicates the switchgear breaker types available in the UPS system.
If the UPS is unable to find any attached breakers, this variable is set to unknown(1). If the system has multiple breakers of the same type (e.g. mul… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.13.5.1.7.1.4 |
||||||||||||||||||||
|
switchgearBreakerStatusmandatory
The status of switchgear breaker.
unknown(1) indicates the breaker status is unknown. opened (2) indicates the breaker is opened. closed (3) indicates the breaker is closed. NOTE: If there are more than one breaker of t… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.13.5.1.7.1.5 |
.1.3.6.1.4.1.318.1.1.1.13.5.1.9
·
1 row entry
·
8 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsDiagSubFeedBreakerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsDiagSubFeedBreakerTable'
Subfeed breaker table.
A list of subfeed breakers.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
subfeedBreakerIndexmandatory
The index of the subfeed breakers.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.5.1.9.1.1 |
||||||||
|
subfeedBreakerPresentmandatory
Indicates if the subfeed breaker is present.
notPresent (1) indicates that the breaker is not present. present (2) indicates that the breaker is present. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.13.5.1.9.1.2 |
||||||||
|
subfeedBreakerRatingmandatory
The current rating of the installed subfeed breaker.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.5.1.9.1.3 |
||||||||
|
The maximum acceptable load before warning is issued.
Expressed as percent of the subfeed breaker rating. |
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.318.1.1.1.13.5.1.9.1.4 |
||||||||
|
The maximum load before a critical alarm occurs.
Expressed as percent of the subfeed breaker rating. |
Integer32r/w Constraints: range: 0-125 |
.1.3.6.1.4.1.318.1.1.1.13.5.1.9.1.5 |
||||||||
|
subfeedBreakerStatusmandatory
The status of the Circuit Breaker.
unknown(1) indicates the circuit breaker status is unknown. notInstalled(2) indicates the circuit breaker is not installed. opened(3) indicates the circuit breaker is opened. closed(4)… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.13.5.1.9.1.6 |
||||||||
|
subfeedBreakerNamemandatory
The name of the subfeed breaker.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.1.13.5.1.9.1.7 |
||||||||
|
subfeedBreakerCurrentmandatory
The subfeed current in tenths of Amps.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.5.1.9.1.8 |
.1.3.6.1.4.1.318.1.1.1.13.5.1.11
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsDiagSubFeedPhaseTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsDiagSubFeedPhaseTable'
A list of subfeed phase table.
An entry containing information applicable to a
particular phase.
particular phase.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
upsDiagSubFeedBreakerIndexmandatory
The subfeed breaker index.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.5.1.11.1.1 |
|
upsDiagSubFeedPhaseIndexmandatory
The subfeed phase index.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.5.1.11.1.2 |
|
upsDiagSubFeedPhaseCurrentmandatory
The subfeed phase current in Amps.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.5.1.11.1.3 |
|
upsDiagSubFeedPhaseCurrentAlternatemandatory
The subfeed phase current in tenths of Amps.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.5.1.11.1.4 |
.1.3.6.1.4.1.318.1.1.1.13.5.1.15
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsDiagUsrSuppSwitchgearMonitorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsDiagUsrSuppSwitchgearMonitorTable'
Allows for diagnostics of the user supplied Switch Gear Monitor Board.
The diagnostics of the user supplied Switch Gear Monitor Board.
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
upsDiagUsrSuppSwitchgearMonitorIndexmandatory
The index of the user supplied Switch Gear Monitor Board.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.5.1.15.1.1 |
||||||||||||||
|
The status of the user supplied Switch Gear Monitor Board.
unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. on… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.13.5.1.15.1.2 |
||||||||||||||
|
The firmware revision of the user supplied Switch Gear Monitor Board.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.5.1.15.1.3 |
||||||||||||||
|
The hardware revision of the user supplied Switch Gear Monitor Board.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.5.1.15.1.4 |
||||||||||||||
|
The serial number of the user supplied
Switch Gear Monitor Board. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.5.1.15.1.5 |
||||||||||||||
|
The temperature of the air around the user supplied
Switch Gear Monitor Board in tenths of degrees Celsius. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.5.1.15.1.6 |
.1.3.6.1.4.1.318.1.1.1.13.7.2
·
1 row entry
·
2 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsDiagnosticPowerCabinetTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsDiagnosticPowerCabinetTable'
Allows for diagnostics of individual Power Cabinets. The number of entries is contained in the upsDiagnosticPowerCabinetTableSize OID.
The diagnostics of a Power Cabinet.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
upsDiagnosticPowerCabinetIndexmandatory
The index to the Power Cabinet.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.7.2.1.1 |
|
The ambient temperature of Power Cabinet in tenths of degrees Celsius.
If the Power Cabinet is not present, this variable is set to (-1). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.7.2.1.2 |
.1.3.6.1.4.1.318.1.1.1.13.9.2
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsDiagUnitControllerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsDiagUnitControllerTable'
Allows for diagnostics of individual Intelligence Modules. The number of entries is contained in the upsDiagUnitControllerTableSize OID.
The diagnostics and information of an Intelligence Module.
Indexes
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
upsDiagUnitControllerIndexmandatory
The index to the Unit Controller entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.13.9.2.1.1 |
||||||||||||||
|
upsDiagUnitControllerStatusmandatory
The status of the Unit Controller.
unknown(1) indicates the device status is unknown. notInstalled(2) indicates the device is not installed. offOk(3) indicates the device status is off and OK. onOk(4) indicates the devi… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.13.9.2.1.2 |
||||||||||||||
|
upsDiagUnitControllerFirmwareRevmandatory
The firmware revision of the Unit Controller.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.9.2.1.3 |
||||||||||||||
|
upsDiagUnitControllerHardwareRevmandatory
The hardware revision of the Unit Controller.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.9.2.1.4 |
||||||||||||||
|
upsDiagUnitControllerSerialNummandatory
The serial number of the Unit Controller.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.9.2.1.5 |
||||||||||||||
|
upsDiagUnitControllerModelNummandatory
The model number of the Unit Controller.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.13.9.2.1.6 |
.1.3.6.1.4.1.318.1.1.1.14.7
·
1 row entry
·
10 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsParallelInputPhaseTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsParallelInputPhaseTable'
A list of input table entries.
An entry containing information applicable to a
particular input phase.
particular input phase.
| Column | Syntax | OID |
|---|---|---|
|
upsParallelInputPhaseTableIndexmandatory
The parallel unit identifier.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.14.7.1.1 |
|
upsParallelInputPhaseIndexmandatory
The input phase identifier.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.14.7.1.2 |
|
upsParallelInputCurrentmandatory
The input current in amperes, or -1 if it's
unsupported by this UPS. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.14.7.1.3 |
|
upsParallelInputActivePowermandatory
The input power in kW, or -1 if it's
unsupported by this UPS. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.14.7.1.4 |
|
upsParallelInputApparentPowermandatory
The input apparent power in kVA, or -1 if it's
unsupported by this UPS. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.14.7.1.5 |
|
upsParallelInputVoltagemandatory
The input voltage of UPS in volts, or -1 if it's
unsupported by this UPS. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.14.7.1.6 |
|
upsParallelInputMaxVoltagemandatory
The peak input voltage in VAC measured since the last reset,
or -1 if it's unsupported by this UPS. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.14.7.1.7 |
|
upsParallelInputMaxCurrentmandatory
The peak input current in amperes measured since last reset,
or -1 if it's unsupported by this UPS. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.14.7.1.8 |
|
upsParallelInputTotalActivePowermandatory
Total active input power of the parallel system in kW.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.14.7.1.9 |
|
upsParallelInputTotalApparentPowermandatory
Total apparent input power of the parallel system in kVA.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.14.7.1.10 |
.1.3.6.1.4.1.318.1.1.1.14.8
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsParallelOutputPhaseTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsParallelOutputPhaseTable'
A list of output table entries. The number of entries is given by the sum of the upsPhaseNumOutputPhases.
An entry containing information applicable to a
particular output phase.
particular output phase.
| Column | Syntax | OID |
|---|---|---|
|
upsParallelOutputPhaseTableIndexmandatory
The output identifier.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.14.8.1.1 |
|
upsParallelOutputPhaseIndexmandatory
The output phase identifier.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.14.8.1.2 |
|
upsParallelOutputCurrentmandatory
The output current in amperes drawn
by the load on the UPS, or -1 if it's unsupported by this UPS. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.14.8.1.3 |
|
upsParallelOutputLoadmandatory
The output load in VA, or -1 if it's unsupported
by this UPS. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.14.8.1.4 |
|
upsParallelOutputPercentLoadmandatory
The percentage of the UPS load capacity in VA at
present redundancy being used on this output phase, or -1 if it's unsupported by this UPS. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.14.8.1.5 |
|
upsParallelOutputPowermandatory
The output power in Watts, or -1 if it's
unsupported by this UPS. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.14.8.1.6 |
.1.3.6.1.4.1.318.1.1.1.14.9
·
1 row entry
·
2 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsParallelOutputApparentPowerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsParallelOutputApparentPowerTable'
A list of output table entries. The number of entries is given by the value of upsOutputNumPhases.
An entry containing information applicable to a
particular output.
particular output.
| Column | Syntax | OID |
|---|---|---|
|
The UPS parallel output identifier.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.14.9.1.1 |
|
upsParallelOutputApparentPowermandatory
The apparent power of each of UPS in kVA
when UPS are configured in parallel. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.14.9.1.2 |
.1.3.6.1.4.1.318.1.1.1.14.10
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsParallelDiagSubSysBreakerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsParallelDiagSubSysBreakerTable'
Allows for diagnostics of parallel Circuit Breakers.
The diagnostics of Circuit Breaker.
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
The Parallel UPS index entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.14.10.1.1 |
||||||||
|
upsParallelDiagSubSysBreakerIndexmandatory
The index of the Circuit Breaker.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.14.10.1.2 |
||||||||
|
upsParallelDiagSubSysBreakerStatusmandatory
The status of the Circuit Breaker.
unknown(1) indicates the circuit breaker status is unknown. notInstalled(2) indicates the circuit breaker is not installed. opened(3) indicates the circuit breaker is opened. closed(4)… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.14.10.1.3 |
||||||||
|
upsParallelDiagSubSysBreakerNamemandatory
The name of Circuit Breaker.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.14.10.1.4 |
.1.3.6.1.4.1.318.1.1.1.14.12
·
1 row entry
·
2 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsParallelOutputActivePowerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsParallelOutputActivePowerTable'
A list of output table entries. The number of entries is given by the value of upsParallelSysRemoteAddress.
An entry containing information applicable to a
particular output.
particular output.
| Column | Syntax | OID |
|---|---|---|
|
The UPS parallel output identifier.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.14.12.1.1 |
|
upsParallelOutputActivePowermandatory
The active power of each UPS in kW
when UPS devices are configured in parallel. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.14.12.1.2 |
.1.3.6.1.4.1.318.1.1.1.14.17
·
1 row entry
·
5 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsParallelSysUpsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsParallelSysUpsTable'
A list of UPS table entries. The number of entries is given by the value of upsParallelSysUpsTableize.
An entry containing information applicable to a
particular UPS in parallel.
particular UPS in parallel.
Indexes
| Column | Syntax | OID | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
upsParallelSysUpsIndexmandatory
The index to the Parallel System UPS table entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.14.17.1.1 |
||||||||||||||||||||||
|
upsParallelSysUpsNamemandatory
The UPS id as assigned by the system.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.14.17.1.2 |
||||||||||||||||||||||
|
upsParallelSysUpsAlarmStatusmandatory
The alarm status of the UPS.
unknown(1) indicates the UPS status is unknown. normal(2) indicates UPS is functioning normally. informational(3) indicates informational alarm present in the UPS. warning(4) indicates warni… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.14.17.1.3 |
||||||||||||||||||||||
|
upsParallelSysUpsModemandatory
The current operating mode of the UPS. If the UPS is unable to
determine the state of the UPS, this variable is set to unknown(1). |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.14.17.1.4 |
||||||||||||||||||||||
|
upsParallelSysUpsSerialNumbermandatory
The Serial number of the UPS in parallel.
Equivalent to OID 1.3.6.1.4.1.318.1.1.1.1.2.3 (upsAdvIdentSerialNumber). |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.14.17.1.5 |
.1.3.6.1.4.1.318.1.1.1.15.5
·
1 row entry
·
2 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsBatteryFrameLayoutTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsBatteryFrameLayoutTable'
Battery frame layout position ID table.
A list of layout position IDs of battery frames.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
batteryFrameIndexmandatory
The index of the battery frame.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.15.5.1.1 |
|
batteryFramePositionIDmandatory
Defines the position ID of each of the battery frames in the row.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.15.5.1.2 |
.1.3.6.1.4.1.318.1.1.1.15.7
·
1 row entry
·
2 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsSideCarFrameLayoutTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsSideCarFrameLayoutTable'
Sidecar frame layout position ID table.
A list of sidecar frame layout position IDs.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
sideCarFrameIndexmandatory
The index of the sidecar frame.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.15.7.1.1 |
|
sideCarFramePositionIDmandatory
Defines the position ID of each of the sidecar frames in the row.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.15.7.1.2 |
.1.3.6.1.4.1.318.1.1.1.15.9
·
1 row entry
·
2 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsPowerFrameLayoutTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsPowerFrameLayoutTable'
Power frame layout position ID table.
A list of power frame layout position IDs.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
powerFrameIndexmandatory
The index of the power frame.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.15.9.1.1 |
|
powerFramePositionIDmandatory
Defines the position ID of each of the power frames in the row.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.15.9.1.2 |
.1.3.6.1.4.1.318.1.1.1.16.5
·
1 row entry
·
5 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsIntegratedATSSourceTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsIntegratedATSSourceTable'
Allows for getting status and settings for the ATS input sources. The number of entries is contained in the upsIntegratedATSSourceTableSize OID.
The input source status to get.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
upsIntegratedATSSourceIndexmandatory
The index to the input source entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.16.5.1.1 |
||||||
|
upsIntegratedATSSourceNamemandatory
The name of the input source. This OID is provided
for informational purposes only. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.16.5.1.2 |
||||||
|
upsIntegratedATSSourceStatusmandatory
Getting this variable will return the input source status.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.16.5.1.3 |
||||||
|
upsIntegratedATSLineFailDelaymandatory
The delay between a selected input source becoming bad, and the ATS switching away from that source.
This delay is used to make sure that the line has truly failed before the ATS will be switched. Specified in seconds. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.16.5.1.4 |
||||||
|
upsIntegratedATSLineStabilityDelaymandatory
The delay between an unselected input source becoming good, and the ATS switching to that source.
This delay is used to make sure that the line has truly returned before the ATS will be switched. Specified in seconds. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.16.5.1.5 |
.1.3.6.1.4.1.318.1.1.1.17.1.2
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsDCOutputStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsDCOutputStatusTable'
Provides status information on UPS DC outputs. The number of entries is contained in the upsDCOutputStatusTableSize OID.
The DC output.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
upsDCOutputStatusTableIndexmandatory
The index to the DC output status entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.17.1.2.1.1 |
|
upsDCOutputStatusVoltageNominalmandatory
The desired voltage for this output in tenths of VDC.
When the output is on and there are no fault conditions, the actual voltage should be near the nominal. If not supported, return -1. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.17.1.2.1.2 |
|
upsDCOutputStatusCurrentRatingmandatory
The amount of current this output is able to supply in
tenths of amperes. If not supported, return -1. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.17.1.2.1.3 |
|
upsDCOutputStatusVoltagemandatory
The voltage measured on this output in tenths of VDC.
If not supported, return -1. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.17.1.2.1.4 |
|
upsDCOutputStatusCurrentmandatory
The current drawn by the load measured on this output
in tenths of amperes. If not supported, return -1. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.17.1.2.1.5 |
|
upsDCOutputStatusAbnormalConditionsmandatory
An ASCII string containing flags representing active
output faults. If the Network Card is unable to determine the state of the faults, this variable is set to 'UNKNOWN'. The flags are numbered 1 onward, … |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.17.1.2.1.6 |
.1.3.6.1.4.1.318.1.1.1.18.1.2
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsOutputRelayStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsOutputRelayStatusTable'
Allows for access of individual relays.
The output relays to access.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
upsOutputRelayIndexmandatory
The index to the output relay entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.18.1.2.1.1 |
||||
|
upsOutputRelayStatemandatory
Getting this variable will return the output relay state.
1 - normal state 2 - abnormal state |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.18.1.2.1.2 |
||||
|
upsOutputRelayDetailedStatusmandatory
An ASCII string containing the 16 flags representing
the status of the output relay. The flags are numbered from 1 to 16, and read from left to right. The bits are defined as follows: Flag … |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.1.18.1.2.1.3 |
.1.3.6.1.4.1.318.1.1.1.18.1.4
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsOutputRelayConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsOutputRelayConfigTable'
Allows for access of individual relays.
The output relays to access.
Indexes
| Column | Syntax | OID | ||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
upsOutputRelayConfigIndexmandatory
The index to the output relay entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.18.1.4.1.1 |
||||||||||||||||||||
|
upsOutputRelayConfigDelaymandatory
Output relay delay 0 - 86400 seconds.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.18.1.4.1.2 |
||||||||||||||||||||
|
upsOutputRelayConfigCausemandatory
This variable sets what causes the output relay state to change.
1 - none 2 - on battery power failure 3 - on battery power failure expect during peak period 4 - low battery while on battery 5 - alarm 6 - fault 7 - outp… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.18.1.4.1.3 |
.1.3.6.1.4.1.318.1.1.1.18.2.2
·
1 row entry
·
2 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsInputContactStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsInputContactStatusTable'
Allows for access of individual contacts.
The input contacts to access.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
upsInputContactIndexmandatory
The index to the input contact entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.18.2.2.1.1 |
||||
|
upsInputContactStatemandatory
Getting this variable will return the input contact state.
1 - normal state 2 - abnormal state |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.18.2.2.1.2 |
.1.3.6.1.4.1.318.1.1.1.18.2.4
·
1 row entry
·
2 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk upsInputContactConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::upsInputContactConfigTable'
Allows for access of individual contacts.
The input contacts to access.
Indexes
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
upsInputContactConfigIndexmandatory
The index to the input contact entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.1.18.2.4.1.1 |
||||||||||||
|
upsInputContactConfigActionmandatory
When the input contact changes state, this action occurs.
1 - none 2 - self test 3 - external alarm on 4 - external alarm off 5 - output off no delay 6 - output on |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.1.18.2.4.1.2 |
.1.3.6.1.4.1.318.1.1.2.2.2
·
1 row entry
·
5 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk mUpsContactTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::mUpsContactTable'
A list of contacts supported by the Measure-UPS.
A contact entry containing information for a given contact.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
contactNumbermandatory
An index identifying the contact on the Measure-UPS.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.2.2.2.1.1 |
||||||
|
normalStatemandatory
The normal operating position of the contact. If the normal
operating position cannot be set then it is controlled via the dip switch on the Measure-UPS and is therefore read-only. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.2.2.2.1.2 |
||||||
|
descriptionmandatory
The description of the purpose/use of the contact.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.2.2.2.1.3 |
||||||
|
monitoringStatusmandatory
A flag indicating whether this contact is
monitored, or not. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.2.2.2.1.4 |
||||||
|
currentStatusmandatory
This value indicates the current state of the contact.
If the contact is not in its normal state. This value is set to fault(2). |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.2.2.2.1.5 |
.1.3.6.1.4.1.318.1.1.4.4.2
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk sPDUOutletControlTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::sPDUOutletControlTable'
Allows for control of individual outlet switches. The number of entries is contained in the sPDUOutletControlTableSize OID.
The outlets to control.
Indexes
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
sPDUOutletControlIndexmandatory
The index to the outlet entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.4.4.2.1.1 |
||||||||||||||
|
sPDUOutletPendingmandatory
Reports whether the current outlet has a pending command.
If the commandPendingUnknown (3) value is returned, all devices powered by the PDU should be shut down. The PDU's power should then be cycled to c… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.4.4.2.1.2 |
||||||||||||||
|
sPDUOutletCtlmandatory
Getting this variable will return the outlet state. If
the outlet is on, the outletOn (1) value will be returned. If the outlet is off, the outletOff (2) value will be returned. If the state of the outlet… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.4.4.2.1.3 |
||||||||||||||
|
sPDUOutletCtlNamemandatory
The name of the outlet. Maximum size is 20 characters.
This OID is provided for informational purposes only. This value is set by the sPDUOutletName OID. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.4.4.2.1.4 |
.1.3.6.1.4.1.318.1.1.4.5.2
·
1 row entry
·
5 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk sPDUOutletConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::sPDUOutletConfigTable'
The list of outlets to configure. The number of entries is defined by the sPDUOutletConfigTableSize OID.
The outlets to control.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
sPDUOutletConfigIndexmandatory
The index to the outlet entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.4.5.2.1.1 |
|
sPDUOutletPowerOnTimemandatory
The amount of time (in seconds) the outlet will delay
powering on when the MasterSwitch is powered on. Allowed values are: -1 never power on automatically. 0 power on with the Master Switc… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.4.5.2.1.2 |
|
sPDUOutletNamemandatory
The name of the outlet. Maximum size is 20 characters.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.4.5.2.1.3 |
|
sPDUOutletPowerOffTimemandatory
The amount of time (in seconds) the outlet will delay
powering off. Allowed values are: -1 never power off automatically. 0 power off with the MasterSwitch. 15 power off 15 seconds after b… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.4.5.2.1.4 |
|
sPDUOutletRebootDurationmandatory
During a reboot sequence, power is turned off and then
back on. This OID defines the amount of time to wait, in seconds, after turning the power off, at the start of the sequence, before turning power back on, at the en… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.4.5.2.1.5 |
.1.3.6.1.4.1.318.1.1.5.1.2
·
1 row entry
·
7 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk sPDUIdentVMTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::sPDUIdentVMTable'
Allows for query of the individual MasterSwitch VMs. The number of entries is contained in the sPDUIdentVMTableSize OID.
The MasterSwitch VMs to query.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
sPDUIdentVMIndexmandatory
The index to the MasterSwitch VM entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.5.1.2.1.1 |
|
sPDUIdentNameVMmandatory
A 23-character string identifying the
MasterSwitch VM. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.5.1.2.1.2 |
|
sPDUIdentHardwareRevVMmandatory
The hardware version of the MasterSwitch VM.
This value is set at the factory. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.5.1.2.1.3 |
|
sPDUIdentFirmwareRevVMmandatory
An 6-character ID string identifying the MasterSwitch VM
firmware version. This value is set at the factory. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.5.1.2.1.4 |
|
sPDUIdentDateOfManufactureVMmandatory
The date when the MasterSwitch VM was manufactured in mm/dd/yyyy format.
This value is set at the factory. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.5.1.2.1.5 |
|
sPDUIdentModelNumberVMmandatory
A 17-character string identifying the model number of
the MasterSwitch VM. This value is set at the factory. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.5.1.2.1.6 |
|
sPDUIdentSerialNumberVMmandatory
A 17-character string identifying the serial number of
the MasterSwitch VM. This value is set at the factory. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.5.1.2.1.7 |
.1.3.6.1.4.1.318.1.1.5.2.2
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk sPDUMasterControlVMTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::sPDUMasterControlVMTable'
Allows for control of the individual MasterSwitch VMs. The number of entries is contained in the sPDUMasterControlVMTableSize OID.
The MasterSwitch VMs to control.
Indexes
| Column | Syntax | OID | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
sPDUMasterControlVMIndexmandatory
The index to the MasterSwitch VM entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.5.2.2.1.1 |
||||||||||||||||||||||
|
sPDUMasterControlVMNamemandatory
The name of the MasterSwitch VM. The maximum
value is 23 characters. The name is set by using the sPDUMasterConfigVMName OID. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.5.2.2.1.2 |
||||||||||||||||||||||
|
sPDUMasterControlVMCommandmandatory
Setting this OID to immediateAllOnVM (2) will turn all outlets
on immediately. Setting this OID to immediateAllOffVM (3) will turn all outlets off immediately. Setting this OID to immediate… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.5.2.2.1.3 |
.1.3.6.1.4.1.318.1.1.5.3.2
·
1 row entry
·
7 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk sPDUMasterConfigVMTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::sPDUMasterConfigVMTable'
Allows for configuration of the individual MasterSwitch VMs. The number of entries is contained in the sPDUMasterConfigVMTableSize OID.
The MasterSwitch VMs to configure.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
sPDUMasterConfigVMIndexmandatory
The index to the MasterSwitch VM entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.5.3.2.1.1 |
||||||
|
sPDUMasterConfigVMNamemandatory
The name of the MasterSwitch VM. Maximum size is 23 characters.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.5.3.2.1.2 |
||||||
|
sPDUMasterConfigVMColdstartDelaymandatory
The amount of delay, in seconds, between when
power is provided to the MasterSwitch VM and when the MasterSwitch VM provides basic master power to the outlets. Allowed values are: -1 never … |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.5.3.2.1.3 |
||||||
|
Setting this OID to audioAlarmActiveNever (1) will disable
the audio alarm on the MasterSwitch VM. Setting this OID to audioAlarmActiveOnOverload (2) will activate the audio alarm on the MasterSwitch VM w… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.5.3.2.1.4 |
||||||
|
A threshold that indicates the power consumption of
the load is nearing an overload condition. It is represented as a percentage of full load. |
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.318.1.1.5.3.2.1.5 |
||||||
|
A threshold that indicates the power consumption of
the load is nearing a low consumption condition. It is represented as a percentage of full load. |
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.318.1.1.5.3.2.1.6 |
||||||
|
This OID controls the behavior of the MasterSwitch VM
when an overload condition is possible and additional outlets are requested to be turned on. Setting this OID to alwaysAllowTurnON (1) will always all… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.5.3.2.1.7 |
.1.3.6.1.4.1.318.1.1.5.4.2
·
1 row entry
·
9 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk sPDUMasterStatusVMTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::sPDUMasterStatusVMTable'
Allows for gathering of status from the individual MasterSwitch VMs. The number of entries is contained in the sPDUMasterStatusVMTableSize OID.
The MasterSwitch VMs to gather status from.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
sPDUMasterStatusVMIndexmandatory
The index to the MasterSwitch VM entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.5.4.2.1.1 |
||||
|
sPDUMasterStatusVMNamemandatory
The name of the MasterSwitch VM. Maximum size is 23 characters.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.5.4.2.1.2 |
||||
|
sPDUMasterStatusVMCommandPendingmandatory
Getting this OID will return commandPendingMasterTrueVM (1)
if the MasterSwitch VM has a pending command on any of its outlets. commandPendingMasterFalseVM (2) will be returned if there are no pending com… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.5.4.2.1.3 |
||||
|
sPDUMasterStatusVMOverloadConditionmandatory
Getting this OID will return overloadConditionTrueVM (1)
if the sPDUMasterConfigVMHighLoadWarningThreshold OID is violated. overloadConditionFalseVM (2) will be returned if the sPDUMasterConfigVMHighLoadW… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.5.4.2.1.4 |
||||
|
sPDUMasterStatusVMLowLoadConditionmandatory
Getting this OID will return lowLoadConditionTrueVM (1)
if the sPDUMasterConfigVMLowLoadWarningThreshold OID is violated. lowLoadConditionFalseVM (2) will be returned if the sPDUMasterConfigVMHighLoadWarn… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.5.4.2.1.5 |
||||
|
sPDUMasterStatusVMCurrentLoadmandatory
Getting this OID will return the total amount of power
being consumed by the load. It is represented as a percentage of full load. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.5.4.2.1.6 |
||||
|
sPDUMasterStatusVMMaxLoadmandatory
Getting this OID will return the total amount of power
that this MasterSwitch VM can provide. It is represented in Amps. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.5.4.2.1.7 |
||||
|
sPDUMasterStatusVMOutletCountmandatory
Getting this OID will return the number of controllable
outlets for this MasterSwitch VM. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.5.4.2.1.8 |
||||
|
sPDUMasterStatusVMRebootDurationmandatory
Getting this OID will return the largest
sPDUOutletConfigVMRebootDuration OID time for this MasterSwitch VM. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.5.4.2.1.9 |
.1.3.6.1.4.1.318.1.1.5.5.1
·
1 row entry
·
5 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk sPDUOutletControlVMTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::sPDUOutletControlVMTable'
Allows for control of individual outlet switches. The number of entries is contained in the sPDUMasterStatusOutletCount OID.
The outlets to control.
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
sPDUOutletControlVMIndexmandatory
The index to the MasterSwitch VM.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.5.5.1.1.1 |
||||||||||||||
|
sPDUOutletControlVMNamemandatory
The name of the MasterSwitch VM. Maximum size is 23 characters.
This OID is provided for informational purposes only. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.5.5.1.1.2 |
||||||||||||||
|
sPDUOutletControlVMOutletIndexmandatory
The index to the outlet entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.5.5.1.1.3 |
||||||||||||||
|
sPDUOutletControlVMOutletNamemandatory
The name of the outlet. Maximum size is 23 characters.
This OID is provided for informational purposes only. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.5.5.1.1.4 |
||||||||||||||
|
sPDUOutletControlVMOutletCommandmandatory
Getting this variable will return the outlet state. If
the outlet is on, the immediateOnVM (1) value will be returned. If the outlet is off, the immediateOffVM (2) value will be returned. S… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.5.5.1.1.5 |
.1.3.6.1.4.1.318.1.1.5.6.1
·
1 row entry
·
7 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk sPDUOutletConfigVMTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::sPDUOutletConfigVMTable'
Allows for configuration of individual outlets. The number of entries is contained in the sPDUMasterStatusOutletCount OID.
The outlets to configure.
| Column | Syntax | OID |
|---|---|---|
|
sPDUOutletConfigVMIndexmandatory
The index to the MasterSwitch VM.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.5.6.1.1.1 |
|
sPDUOutletConfigVMNamemandatory
The name of the MasterSwitch VM. Maximum size is 23 characters.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.5.6.1.1.2 |
|
sPDUOutletConfigVMOutletIndexmandatory
The index to the outlet entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.5.6.1.1.3 |
|
sPDUOutletConfigVMOutletNamemandatory
The name of the outlet. Maximum size is 23 characters.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.5.6.1.1.4 |
|
sPDUOutletConfigVMPowerOnTimemandatory
The amount of time (in seconds) the outlet will delay
powering on at coldstart or when a command that requires a turn-on delay is issued. Allowed values are: -1 never power on. 0 power on … |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.5.6.1.1.5 |
|
sPDUOutletConfigVMPowerOffTimemandatory
The amount of time (in seconds) the outlet will delay
powering off when a command that requires a turn-off delay is issued. Allowed values are: -1 never power off automatical… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.5.6.1.1.6 |
|
sPDUOutletConfigVMRebootDurationmandatory
During a reboot sequence, power is turned off and then
back on. This OID defines the amount of time to wait, in seconds, after turning the power off, at the start of the sequence, before turning power back on, at the en… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.5.6.1.1.7 |
.1.3.6.1.4.1.318.1.1.5.7.1
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk sPDUOutletStatusVMTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::sPDUOutletStatusVMTable'
Allows for getting of status of individual outlets. The number of entries is contained in the sPDUMasterStatusOutletCount OID.
The outlets to gather status from.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
sPDUOutletStatusVMIndexmandatory
The index to the MasterSwitch VM.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.5.7.1.1.1 |
||||
|
sPDUOutletStatusVMNamemandatory
The name of the MasterSwitch VM. Maximum size is 23 characters.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.5.7.1.1.2 |
||||
|
sPDUOutletStatusVMOutletIndexmandatory
The index to the outlet entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.5.7.1.1.3 |
||||
|
sPDUOutletStatusVMOutletNamemandatory
The name of the outlet. Maximum size is 23 characters.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.5.7.1.1.4 |
||||
|
sPDUOutletStatusVMOutletStatemandatory
Getting this variable will return the outlet state. If
the outlet is on, the outletStatusOnVM (1) value will be returned. If the outlet is off, the outletStatusOffVM (2) value will be returned. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.5.7.1.1.5 |
||||
|
sPDUOutletStatusVMCommandPendingmandatory
Getting this variable will return the command pending
state of the outlet. If a command is pending on the outlet, the outletStatusVMCommandPending (1) value will be returned. If there is not a command pending on the out… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.5.7.1.1.6 |
.1.3.6.1.4.1.318.1.1.6.1.2
·
1 row entry
·
7 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk sPDUIdentMSPTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::sPDUIdentMSPTable'
Allows for query of the individual MasterSwitch pluses. The number of entries is contained in the sPDUIdentMSPTableSize OID.
The MasterSwitch pluses to query.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
sPDUIdentMSPIndexmandatory
The index to the MasterSwitch plus entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.6.1.2.1.1 |
|
sPDUIdentNameMSPmandatory
The name of the MasterSwitch plus. The maximum
value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.6.1.2.1.2 |
|
sPDUIdentHardwareRevMSPmandatory
The hardware version of the MasterSwitch plus.
This value is set at the factory. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.6.1.2.1.3 |
|
sPDUIdentFirmwareRevMSPmandatory
An 6-character ID string identifying the MasterSwitch plus
firmware version. This value is set at the factory. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.6.1.2.1.4 |
|
sPDUIdentDateOfManufactureMSPmandatory
The date when the MasterSwitch plus was manufactured in mm/dd/yyyy format.
This value is set at the factory. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.6.1.2.1.5 |
|
sPDUIdentModelNumberMSPmandatory
A 17-character string identifying the model number of
the MasterSwitch plus. This value is set at the factory. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.6.1.2.1.6 |
|
sPDUIdentSerialNumberMSPmandatory
A 17-character string identifying the serial number of
the MasterSwitch plus. This value is set at the factory. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.6.1.2.1.7 |
.1.3.6.1.4.1.318.1.1.6.2.2
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk sPDUMasterControlMSPTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::sPDUMasterControlMSPTable'
Allows for control of the individual MasterSwitch pluses. The number of entries is contained in the sPDUMasterControlMSPTableSize OID.
The MasterSwitch pluses to control.
Indexes
| Column | Syntax | OID | ||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
sPDUMasterControlMSPIndexmandatory
The index to the MasterSwitch plus entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.6.2.2.1.1 |
||||||||||||||||||||
|
sPDUMasterControlMSPNamemandatory
The name of the MasterSwitch plus. The maximum
value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.6.2.2.1.2 |
||||||||||||||||||||
|
sPDUMasterControlMSPCommandmandatory
Setting this OID to immediateAllOnMSP (2) will turn all outlets
on immediately. Setting this OID to sequencedAllOnMSP (3) will turn all outlets on as defined by each outlet's sPDUOutletConfigMSPPowerOnDel… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.6.2.2.1.3 |
.1.3.6.1.4.1.318.1.1.6.3.2
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk sPDUMasterConfigMSPTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::sPDUMasterConfigMSPTable'
Allows for configuration of the individual MasterSwitch pluses. The number of entries is contained in the sPDUMasterConfigMSPTableSize OID.
The MasterSwitch pluses to configure.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
sPDUMasterConfigMSPIndexmandatory
The index to the MasterSwitch plus entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.6.3.2.1.1 |
||||
|
sPDUMasterConfigMSPNamemandatory
The name of the MasterSwitch plus. Maximum size is 23 characters.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.6.3.2.1.2 |
||||
|
sPDUMasterConfigMSPPowerOnTimeDelaymandatory
The amount of delay, in seconds, between when
power is provided to the MasterSwitch plus and when the MasterSwitch plus provides basic master power to the outlets. Allowed values are: 0 - 9… |
Integer32r/w Constraints: range: 0-9999 |
.1.3.6.1.4.1.318.1.1.6.3.2.1.3 |
||||
|
sPDUMasterConfigMSPManualButtonmandatory
Setting this OID to manualButtonDisabled (1) will disable
the manual button on the MasterSwitch plus. Setting this OID to manualButtonEnabled (2) will enable the manual button on the MasterSwitch plus. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.6.3.2.1.4 |
.1.3.6.1.4.1.318.1.1.6.4.2
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk sPDUMasterStatusMSPTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::sPDUMasterStatusMSPTable'
Allows for gathering of status from the individual MasterSwitch pluses. The number of entries is contained in the sPDUMasterStatusMSPTableSize OID.
The MasterSwitch pluses to gather status from.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
sPDUMasterStatusMSPIndexmandatory
The index to the MasterSwitch plus entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.6.4.2.1.1 |
|
sPDUMasterStatusMSPNamemandatory
The name of the MasterSwitch plus. The maximum
value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.6.4.2.1.2 |
|
sPDUMasterStatusMSPOutletCountmandatory
Getting this OID will return the number of controllable
outlets for this MasterSwitch plus. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.6.4.2.1.3 |
.1.3.6.1.4.1.318.1.1.6.5.1
·
1 row entry
·
5 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk sPDUOutletControlMSPTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::sPDUOutletControlMSPTable'
Allows for control of individual outlet switches. The number of entries is contained in the sPDUMasterStatusMSPOutletCount OID.
The outlets to control.
| Column | Syntax | OID | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
sPDUOutletControlMSPIndexmandatory
The index to the MasterSwitch plus.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.6.5.1.1.1 |
||||||||||||||||
|
sPDUOutletControlMSPNamemandatory
The name of the MasterSwitch plus. The maximum
value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.6.5.1.1.2 |
||||||||||||||||
|
sPDUOutletControlMSPOutletIndexmandatory
The index to the outlet entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.6.5.1.1.3 |
||||||||||||||||
|
sPDUOutletControlMSPOutletNamemandatory
The name of the outlet. The maximum size is
23 characters. The name is set by using the sPDUOutletConfigMSPallOutletName OID. This OID is provided for informational purposes only. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.6.5.1.1.4 |
||||||||||||||||
|
sPDUOutletControlMSPOutletCommandmandatory
Getting this variable will return the outlet state. If
the outlet is on, the immediateOnMSP (1) value will be returned. If the outlet is off, the immediateOffMSP (3) value will be returned. Setting this v… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.6.5.1.1.5 |
.1.3.6.1.4.1.318.1.1.6.6.1.1
·
1 row entry
·
5 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk sPDUOutletConfigMSPallTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::sPDUOutletConfigMSPallTable'
Allows for configuration of individual outlets. The number of entries is contained in the sPDUMasterStatusMSPOutletCount OID.
The outlets to configure.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
sPDUOutletConfigMSPallIndexmandatory
The index to the MasterSwitch plus.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.6.6.1.1.1.1 |
||||
|
sPDUOutletConfigMSPallNamemandatory
The name of the MasterSwitch plus. The maximum
value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.6.6.1.1.1.2 |
||||
|
sPDUOutletConfigMSPallOutletIndexmandatory
The index to the outlet entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.6.6.1.1.1.3 |
||||
|
sPDUOutletConfigMSPallOutletNamemandatory
The name of the outlet. Maximum size is 23 characters.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.6.6.1.1.1.4 |
||||
|
sPDUOutletConfigMSPallOutletCtrlModemandatory
Setting this OID to modeGracefulShutdown (1) will put this
outlet into the Graceful Shutdown control mode. Setting this OID to modeAnnunciator (2) will put this outlet into the Annunciator control mode. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.6.6.1.1.1.5 |
.1.3.6.1.4.1.318.1.1.6.6.2.1
·
1 row entry
·
13 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk sPDUOutletConfigMSPgsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::sPDUOutletConfigMSPgsTable'
Allows for configuration of individual outlets. The number of entries is contained in the sPDUMasterStatusMSPOutletCount OID.
The outlets to configure.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
sPDUOutletConfigMSPgsIndexmandatory
The index to the MasterSwitch plus.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.6.6.2.1.1.1 |
||||
|
sPDUOutletConfigMSPgsNamemandatory
The name of the MasterSwitch plus. The maximum
value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.6.6.2.1.1.2 |
||||
|
sPDUOutletConfigMSPgsOutletIndexmandatory
The index to the outlet entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.6.6.2.1.1.3 |
||||
|
sPDUOutletConfigMSPgsOutletNamemandatory
The name of the outlet. The maximum size is
23 characters. The name is set by using the sPDUOutletConfigMSPallOutletName OID. This OID is provided for informational purposes only. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.6.6.2.1.1.4 |
||||
|
sPDUOutletConfigMSPgsOutletCtrlModemandatory
The Control Mode of the outlet.
This OID is provided for informational purposes only. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.6.6.2.1.1.5 |
||||
|
sPDUOutletConfigMSPgsDeviceConfirmmandatory
Setting this OID to deviceConfirmNo (1) cause the outlet to
NOT wait for device confirmation while performing graceful operations. Setting this OID to deviceConfirmYes (2) cause the outlet to wait for dev… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.6.6.2.1.1.6 |
||||
|
sPDUOutletConfigMSPgsLowBattWarningmandatory
The amount of delay, in 6 second intervals, between
when the UPS goes on battery and the power down sequence for the outlet is initiated. Allowed values are: -2 - Never initiate the power d… |
Integer32r/w Constraints: range: -2-9999 |
.1.3.6.1.4.1.318.1.1.6.6.2.1.1.7 |
||||
|
sPDUOutletConfigMSPgsLowBattMultmandatory
Only applicable if sPDUOutletConfigMSPgsLowBattWarning OID is
set to -1 (On Runtime Remaining). Allows you to set the value to stagger the shutdown sequence of the outlets. 1 provides the longest delay (t… |
Integer32r/w Constraints: range: 1-7 |
.1.3.6.1.4.1.318.1.1.6.6.2.1.1.8 |
||||
|
sPDUOutletConfigMSPgsRestartDelaymandatory
The amount of delay, in 6 minute intervals, between
when the outlet is turned off and the outlet is turned back on when performing a Graceful Shutdown. Allowed values are: -1 - Never turn o… |
Integer32r/w Constraints: range: -1-9999 |
.1.3.6.1.4.1.318.1.1.6.6.2.1.1.9 |
||||
|
sPDUOutletConfigMSPgsPowerOnDelaymandatory
The amount of delay, in seconds, between the UPS entering
normal (on-line) state and the outlet being powered on. Allowed values are: -1 - Remain Off when the UPS enters the on-line state. … |
Integer32r/w Constraints: range: -1-9999 |
.1.3.6.1.4.1.318.1.1.6.6.2.1.1.10 |
||||
|
sPDUOutletConfigMSPgsPowerOffDelaymandatory
The amount of delay, in seconds, between when the server
shuts down and the outlet is powered off. Allowed values are: 0 - 9999 seconds (0 - 2 hrs, 46 mins, 39 secs). |
Integer32r/w Constraints: range: 0-9999 |
.1.3.6.1.4.1.318.1.1.6.6.2.1.1.11 |
||||
|
sPDUOutletConfigMSPgsBattCapThreshmandatory
The minimum battery capacity, as a percent (0-100%), required
of the UPS before an outlet will be allowed to power on. Allowed values are: 0 - 100 percent. |
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.318.1.1.6.6.2.1.1.12 |
||||
|
sPDUOutletConfigMSPgsRebootDurationmandatory
The amount of delay, in seconds, from outlet off until
outlet on during a reboot. Allowed values are: 0 - 9999 seconds (0 - 2 hrs, 46 mins, 39 secs). |
Integer32r/w Constraints: range: 0-9999 |
.1.3.6.1.4.1.318.1.1.6.6.2.1.1.13 |
.1.3.6.1.4.1.318.1.1.6.6.3.1
·
1 row entry
·
7 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk sPDUOutletConfigMSPannunTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::sPDUOutletConfigMSPannunTable'
Allows for configuration of individual outlets. The number of entries is contained in the sPDUMasterStatusMSPOutletCount OID.
The outlets to configure.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
sPDUOutletConfigMSPannunIndexmandatory
The index to the MasterSwitch plus.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.6.6.3.1.1.1 |
||||
|
sPDUOutletConfigMSPannunNamemandatory
The name of the MasterSwitch plus. The maximum
value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.6.6.3.1.1.2 |
||||
|
sPDUOutletConfigMSPannunOutletIndexmandatory
The index to the outlet entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.6.6.3.1.1.3 |
||||
|
sPDUOutletConfigMSPannunOutletNamemandatory
The name of the outlet. The maximum size is
23 characters. The name is set by using the sPDUOutletConfigMSPallOutletName OID. This OID is provided for informational purposes only. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.6.6.3.1.1.4 |
||||
|
The Control Mode of the outlet.
This OID is provided for informational purposes only. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.6.6.3.1.1.5 |
||||
|
sPDUOutletConfigMSPannunInitialStatemandatory
Setting this OID to initialStateOff (1) causes the outlet
to default to off when in the non-alarmed condition. Setting this OID to initialStateOn (2) causes the outlet to default to on when in the non-ala… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.6.6.3.1.1.6 |
||||
|
The amount of time, in seconds, that an enabled Measure-UPS
alarm must be asserted before an alarm condition is recognized. Allowed values are: 0 - 9999 seconds (0 - 2 hrs, 46 mins, 39 secs… |
Integer32r/w Constraints: range: 0-9999 |
.1.3.6.1.4.1.318.1.1.6.6.3.1.1.7 |
.1.3.6.1.4.1.318.1.1.6.6.4.1
·
1 row entry
·
16 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk sPDUOutletConfigMSPmupsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::sPDUOutletConfigMSPmupsTable'
Allows for configuration of individual outlets. The number of entries is contained in the sPDUMasterStatusMSPOutletCount OID.
The outlets to configure.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
sPDUOutletConfigMSPmupsIndexmandatory
The index to the MasterSwitch plus.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.6.6.4.1.1.1 |
||||
|
sPDUOutletConfigMSPmupsNamemandatory
The name of the MasterSwitch plus. The maximum
value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.6.6.4.1.1.2 |
||||
|
sPDUOutletConfigMSPmupsOutletIndexmandatory
The index to the outlet entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.6.6.4.1.1.3 |
||||
|
sPDUOutletConfigMSPmupsOutletNamemandatory
The name of the outlet. The maximum size is
23 characters. The name is set by using the sPDUOutletConfigMSPallOutletName OID. This OID is provided for informational purposes only. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.6.6.4.1.1.4 |
||||
|
sPDUOutletConfigMSPmupsZone1mandatory
Setting this OID to disableAlarm (1) disables the
Zone 1 alarm for this outlet. Setting this OID to enableAlarm (2) enables the Zone 1 alarm for this outlet. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.6.6.4.1.1.5 |
||||
|
sPDUOutletConfigMSPmupsZone2mandatory
Setting this OID to disableAlarm (1) disables the
Zone 2 alarm for this outlet. Setting this OID to enableAlarm (2) enables the Zone 2 alarm for this outlet. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.6.6.4.1.1.6 |
||||
|
sPDUOutletConfigMSPmupsZone3mandatory
Setting this OID to disableAlarm (1) disables the
Zone 3 alarm for this outlet. Setting this OID to enableAlarm (2) enables the Zone 3 alarm for this outlet. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.6.6.4.1.1.7 |
||||
|
sPDUOutletConfigMSPmupsZone4mandatory
Setting this OID to disableAlarm (1) disables the
Zone 4 alarm for this outlet. Setting this OID to enableAlarm (2) enables the Zone 4 alarm for this outlet. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.6.6.4.1.1.8 |
||||
|
sPDUOutletConfigMSPmupsP1LowHummandatory
Setting this OID to disableAlarm (1) disables the
Probe 1 low humidity alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 1 low humidity alarm for this outlet. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.6.6.4.1.1.9 |
||||
|
sPDUOutletConfigMSPmupsP1HiHummandatory
Setting this OID to disableAlarm (1) disables the
Probe 1 high humidity alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 1 high humidity alarm for this outlet. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.6.6.4.1.1.10 |
||||
|
sPDUOutletConfigMSPmupsP1LowTempmandatory
Setting this OID to disableAlarm (1) disables the
Probe 1 low temperature alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 1 low temperature alarm for this outlet. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.6.6.4.1.1.11 |
||||
|
sPDUOutletConfigMSPmupsP1HiTempmandatory
Setting this OID to disableAlarm (1) disables the
Probe 1 high temperature alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 1 high temperature alarm for this outlet. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.6.6.4.1.1.12 |
||||
|
sPDUOutletConfigMSPmupsP2LowHummandatory
Setting this OID to disableAlarm (1) disables the
Probe 2 low humidity alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 2 low humidity alarm for this outlet. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.6.6.4.1.1.13 |
||||
|
sPDUOutletConfigMSPmupsP2HiHummandatory
Setting this OID to disableAlarm (1) disables the
Probe 2 high humidity alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 2 high humidity alarm for this outlet. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.6.6.4.1.1.14 |
||||
|
sPDUOutletConfigMSPmupsP2LowTempmandatory
Setting this OID to disableAlarm (1) disables the
Probe 2 low temperature alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 2 low temperature alarm for this outlet. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.6.6.4.1.1.15 |
||||
|
sPDUOutletConfigMSPmupsP2HiTempmandatory
Setting this OID to disableAlarm (1) disables the
Probe 2 high temperature alarm for this outlet. Setting this OID to enableAlarm (2) enables the Probe 2 high temperature alarm for this outlet. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.6.6.4.1.1.16 |
.1.3.6.1.4.1.318.1.1.6.7.1
·
1 row entry
·
7 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk sPDUOutletStatusMSPTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::sPDUOutletStatusMSPTable'
Allows for getting of status of individual outlets. The number of entries is contained in the sPDUMasterStatusOutletCount OID.
The outlets to gather status from.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
sPDUOutletStatusMSPIndexmandatory
The index to the MasterSwitch MSP.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.6.7.1.1.1 |
||||
|
sPDUOutletStatusMSPNamemandatory
The name of the MasterSwitch plus. The maximum
value is 23 characters. The name is set by using the sPDUMasterConfigMSPName OID. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.6.7.1.1.2 |
||||
|
sPDUOutletStatusMSPOutletIndexmandatory
The index to the outlet entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.6.7.1.1.3 |
||||
|
sPDUOutletStatusMSPOutletNamemandatory
The name of the outlet. The maximum size is
23 characters. The name is set by using the sPDUOutletConfigMSPallOutletName OID. This OID is provided for informational purposes only. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.6.7.1.1.4 |
||||
|
sPDUOutletStatusMSPOutletStatemandatory
Getting this variable will return the outlet state. If
the outlet is on, the outletStatusMSPOn (1) value will be returned. If the outlet is off, the outletStatusMSPOff (2) value will be returned. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.6.7.1.1.5 |
||||
|
sPDUOutletStatusMSPCommandPendingmandatory
Getting this variable will return the command pending
state of the outlet. If a command is pending on the outlet, the outletStatusMSPCommandPending (1) value will be returned. If there is not a command pending on the ou… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.6.7.1.1.6 |
||||
|
sPDUOutletStatusMSPOutletCtrlModemandatory
The Control Mode of the outlet.
This OID is provided for informational purposes only. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.6.7.1.1.7 |
.1.3.6.1.4.1.318.1.1.7.1.1.2
·
1 row entry
·
2 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk dm3IdentSysDescriptionTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::dm3IdentSysDescriptionTable'
Allows for accessing description records of the powerplant. The number of entries is contained in the dm3IdentSysDescriptionTableSize OID.
The powerplant description record to reference.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
dm3IdentSysDescriptionIndexmandatory
The index to the DC powerplant description record.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.7.1.1.2.1.1 |
|
dm3IdentSysDescriptionTextmandatory
A 16 character text field describing the DC power plant device.
This field can be configured from the dm3ConfigSysDescriptionText OID. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.7.1.1.2.1.2 |
.1.3.6.1.4.1.318.1.1.7.2.1.2
·
1 row entry
·
2 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk dm3ConfigSysDescriptionTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::dm3ConfigSysDescriptionTable'
Allows for accessing description records of the powerplant. The number of entries is contained in the dm3ConfigSysDescriptionTableSize OID.
The powerplant description record to reference.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
dm3ConfigSysDescriptionIndexmandatory
The index to the DC powerplant description record.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.7.2.1.2.1.1 |
|
dm3ConfigSysDescriptionTextmandatory
16 character text field describing the DC power plant device.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.7.2.1.2.1.2 |
.1.3.6.1.4.1.318.1.1.7.2.2.2
·
1 row entry
·
7 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk dm3ConfigLVDTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::dm3ConfigLVDTable'
Allows for accessing settings of the LVDs. The number of entries is contained in the dm3ConfigLVDTableSize OID.
The LVD to configure.
Indexes
| Column | Syntax | OID | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
dm3ConfigLVDIndexmandatory
The index to the DC powerplant LVD.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.7.2.2.2.1.1 |
||||||||||||||||||
|
dm3ConfigLVDNamemandatory
The name of the LVD. The maximum value is 16 characters.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.7.2.2.2.1.2 |
||||||||||||||||||
|
dm3ConfigLVDEnablemandatory
This OID is used to control and indicate if the LVD is on or off.
Setting this OID to enabledYes (1) will enable (turn on) the LVD. Setting this OID to enabledNo (2) will disable (turn off) the LVD. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.7.2.2.2.1.3 |
||||||||||||||||||
|
dm3ConfigLVDTripThreshmandatory
LVD Trip threshold. If voltage exceeds threshold, the LVD will trip.
Values are represented in thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant … |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.7.2.2.2.1.4 |
||||||||||||||||||
|
dm3ConfigLVDResetThreshmandatory
LVD Reset threshold. If voltage exceeds threshold, the LVD will reset.
Values are represented in thousandths of Volts (mV). Attempts to set the value above or below the acceptable range of the powerplant… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.7.2.2.2.1.5 |
||||||||||||||||||
|
dm3ConfigLVDOpenAlarmmandatory
For the LVD Open Alarm;
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID to al… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.7.2.2.2.1.6 |
||||||||||||||||||
|
dm3ConfigLVDHWAlarmmandatory
For the LVD Hardware Alarm;
Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) causes relay 1 to be activated for an alarm condition. Setting this OID t… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.7.2.2.2.1.7 |
.1.3.6.1.4.1.318.1.1.7.2.5.1.2
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk dm3ConfigOutRlyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::dm3ConfigOutRlyTable'
Allows for accessing settings of the Output Relays. The number of entries is contained in the dm3ConfigOutRlyTableSize OID.
The output relay to configure.
Indexes
| Column | Syntax | OID | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
dm3ConfigOutRlyIndexmandatory
The index to the DC powerplant output relay.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.7.2.5.1.2.1.1 |
||||||||||||||||||
|
dm3ConfigOutRlyNamemandatory
The name of the output relay. The maximum value is 16 characters.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.7.2.5.1.2.1.2 |
||||||||||||||||||
|
dm3ConfigOutRlyDelaymandatory
Output Relay Delay. This OID represents the time delay from the initiation of an
output relay action to when the output relay action does occur. If the alarm condition disappears before the end of the delay, no action… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.7.2.5.1.2.1.3 |
||||||||||||||||||
|
dm3ConfigOutRlyAlarmmandatory
Output Relay Alarm. This setting indicates what action to perform in the event of
an output relay alarm condition; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to a… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.7.2.5.1.2.1.4 |
.1.3.6.1.4.1.318.1.1.7.2.5.2.2
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk dm3ConfigInRlyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::dm3ConfigInRlyTable'
Allows for accessing settings of the Input Relays. The number of entries is contained in the dm3ConfigInRlyTableSize OID.
The input relay to configure.
Indexes
| Column | Syntax | OID | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
dm3ConfigInRlyIndexmandatory
The index to the DC powerplant input relay.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.7.2.5.2.2.1.1 |
||||||||||||||||||
|
dm3ConfigInRlyNamemandatory
The name of the input relay. The maximum value is 16 characters.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.7.2.5.2.2.1.2 |
||||||||||||||||||
|
dm3ConfigInRlyDelaymandatory
Input Relay Delay. This OID represents the time delay from the initiation of an
input relay action to when the input relay action does occur. If the alarm condition disappears before the end of the delay, no action w… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.7.2.5.2.2.1.3 |
||||||||||||||||||
|
dm3ConfigInRlyAlarmmandatory
Input Relay Alarm. This setting indicates what action to perform in the event of
an input relay alarm condition; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to ala… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.7.2.5.2.2.1.4 |
.1.3.6.1.4.1.318.1.1.7.2.6.1.2
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk dm3ConfigBreakersTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::dm3ConfigBreakersTable'
Allows for accessing settings of the circuit breakers. The number of entries is contained in the dm3ConfigBreakersTableSize OID.
The circuit breaker to configure.
Indexes
| Column | Syntax | OID | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
dm3ConfigBreakersIndexmandatory
The index to the DC powerplant circuit breaker.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.7.2.6.1.2.1.1 |
||||||||||||||||||
|
dm3ConfigBreakersNamemandatory
The name of the circuit breaker. The maximum value is 16 characters.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.7.2.6.1.2.1.2 |
||||||||||||||||||
|
dm3ConfigBreakersAlarmmandatory
Circuit Breaker Alarm. This setting indicates what action to perform in the event of
a circuit breaker alarm condition; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.7.2.6.1.2.1.3 |
.1.3.6.1.4.1.318.1.1.7.2.6.2.2
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk dm3ConfigFusesTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::dm3ConfigFusesTable'
Allows for accessing settings of the Fuses. The number of entries is contained in the dm3ConfigFusesTableSize OID.
The fuse to configure.
Indexes
| Column | Syntax | OID | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
dm3ConfigFusesIndexmandatory
The index to the DC powerplant fuse.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.7.2.6.2.2.1.1 |
||||||||||||||||||
|
dm3ConfigFusesNamemandatory
The name of the fuse. The maximum value is 16 characters.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.7.2.6.2.2.1.2 |
||||||||||||||||||
|
dm3ConfigFusesAlarmmandatory
Fuses Alarm. This setting indicates what action to perform in the event of
a Fuse alarm condition; Setting this OID to alarmIgnore (1) results in the alarm condition being ignored. Setting this OID to alarmRelay1 (2) c… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.7.2.6.2.2.1.3 |
.1.3.6.1.4.1.318.1.1.7.3.2.2
·
1 row entry
·
2 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk dm3StatusAlarmsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::dm3StatusAlarmsTable'
Allows for accessing system alarms. The number of entries is contained in the dm3StatusAlarmsTableSize OID.
The alarm to display.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
dm3StatusAlarmsIndexmandatory
The index of the system alarm.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.7.3.2.2.1.1 |
|
dm3StatusAlarmsTextmandatory
The 16 character text describing the active alarm condition.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.7.3.2.2.1.2 |
.1.3.6.1.4.1.318.1.1.7.3.5.2
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk dm3StatusLVDTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::dm3StatusLVDTable'
Allows for accessing settings of the LVDs. The number of entries is contained in the dm3StatusLVDTableSize OID.
The LVD to gather status from.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
dm3StatusLVDIndexmandatory
The index to the DC powerplant LVD.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.7.3.5.2.1.1 |
||||
|
dm3StatusLVDNamemandatory
The name of the LVD. The maximum size is
16 characters. The name is set by using the dm3ConfigLVDName OID. This OID is provided for informational purposes only. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.7.3.5.2.1.2 |
||||
|
dm3StatusLVDStatemandatory
Getting this OID will return statusClosed (1) if the LVD is closed.
statusOpened (2) will be returned if the LVD is opened. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.7.3.5.2.1.3 |
||||
|
dm3StatusLVDHwFaultmandatory
Getting this OID will return statusFault (1) if the LVD is faulted.
statusNofault (2) will be returned if the LVD is not faulted. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.7.3.5.2.1.4 |
.1.3.6.1.4.1.318.1.1.7.3.6.1.2
·
1 row entry
·
16 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk dm3StatusRectTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::dm3StatusRectTable'
Allows for accessing settings of the rectifiers. The number of entries is contained in the dm3StatusRectTableSize OID.
The rectifier to gather status from.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
dm3StatusRectIndexmandatory
The index to the DC powerplant rectifier.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.1 |
||||
|
dm3StatusRectIDmandatory
This OID shows the rectifier ID. This enumerates the number of the rectifier within
a group of rectifiers. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.2 |
||||
|
dm3StatusRectDescmandatory
This OID shows the 16-character rectifier description.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.3 |
||||
|
dm3StatusRectCurrentmandatory
This OID shows the rectifier current in thousandths of Amps (mA).
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.4 |
||||
|
dm3StatusRectCurrentLimitmandatory
Getting this OID will return statusTrue (1) if the rectifier is in the Current Limit state.
statusFalse (2) will be returned if the rectifier is not in the Current Limit state. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.5 |
||||
|
dm3StatusRectStandbymandatory
Getting this OID will return statusTrue (1) if the rectifier is in the Standby state.
statusFalse (2) will be returned if the rectifier is not in the Standby state. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.6 |
||||
|
dm3StatusRectFanFailmandatory
Getting this OID will return statusTrue (1) if the rectifier Fan has failed.
statusFalse (2) will be returned if the rectifier Fan has not failed. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.7 |
||||
|
dm3StatusRectFailmandatory
Getting this OID will return statusTrue (1) if the rectifier has failed.
statusFalse (2) will be returned if the rectifier has not failed. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.8 |
||||
|
dm3StatusRectDevTypemandatory
This OID shows the rectifier device type.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.9 |
||||
|
dm3StatusRectPhyAddrmandatory
This OID shows the rectifier physical address (the address on the bus).
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.10 |
||||
|
dm3StatusRectCfgmandatory
Getting this OID will return statusTrue (1) if the rectifier is present after
power-up or set-configuration. statusFalse (2) will be returned if the rectifier is not configured. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.11 |
||||
|
dm3StatusRectPcbRevmandatory
This OID shows the rectifier device PCB serial number.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.12 |
||||
|
dm3StatusRectFwVermandatory
This OID shows the rectifier device firmware revision.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.13 |
||||
|
dm3StatusRectPresentmandatory
Getting this OID will return statusTrue (1) if the rectifier is present.
statusFalse (2) will be returned if the rectifier is not present. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.14 |
||||
|
dm3StatusRectDiagPassmandatory
Getting this OID will return statusTrue (1) if the rectifier diagnostics have passed.
statusFalse (2) will be returned if the rectifier diagnostics have not passed. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.15 |
||||
|
dm3StatusRectStatemandatory
This OID shows the rectifier device state as defined by the device status register.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.7.3.6.1.2.1.16 |
.1.3.6.1.4.1.318.1.1.7.3.6.2.2
·
1 row entry
·
16 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk dm3StatusConvTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::dm3StatusConvTable'
Allows for viewing status of the converters. The number of entries is contained in the dm3StatusConvTableSize OID.
The converter to gather status from.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
dm3StatusConvIndexmandatory
The index to the DC powerplant converter.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.1 |
||||
|
dm3StatusConvIDmandatory
This OID shows the converter ID. This enumerates the number of the converter within
a group of converters. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.2 |
||||
|
dm3StatusConvDescmandatory
This OID shows the 16 character converter description.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.3 |
||||
|
dm3StatusConvCurrentmandatory
This OID shows the converter current in thousandths of Amps (mA).
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.4 |
||||
|
dm3StatusConvCurrentLimitmandatory
Getting this OID will return statusTrue (1) if the converter is in the Current Limit state.
statusFalse (2) will be returned if the converter is not in the Current Limit state. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.5 |
||||
|
dm3StatusConvStandbymandatory
Getting this OID will return statusTrue (1) if the converter is in the Standby state.
statusFalse (2) will be returned if the converter is not in the Standby state. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.6 |
||||
|
dm3StatusConvFanFailmandatory
Getting this OID will return statusTrue (1) if the converter Fan has failed.
statusFalse (2) will be returned if the converter Fan has not failed. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.7 |
||||
|
dm3StatusConvFailmandatory
Getting this OID will return statusTrue (1) if the converter has failed.
statusFalse (2) will be returned if the converter has not failed. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.8 |
||||
|
dm3StatusConvDevTypemandatory
This OID shows the converter device type.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.9 |
||||
|
dm3StatusConvPhyAddrmandatory
This OID shows the converter physical address (the address on the bus).
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.10 |
||||
|
dm3StatusConvCfgmandatory
Getting this OID will return statusTrue (1) if the converter is present after
power-up or set-configuration. statusFalse (2) will be returned if the converter is not configured. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.11 |
||||
|
dm3StatusConvPcbRevmandatory
This OID shows the converter device PCB serial number.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.12 |
||||
|
dm3StatusConvFwVermandatory
This OID shows the converter device firmware version.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.13 |
||||
|
dm3StatusConvPresentmandatory
Getting this OID will return statusTrue (1) if the converter is present.
statusFalse (2) will be returned if the converter is not present. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.14 |
||||
|
dm3StatusConvDiagPassmandatory
Getting this OID will return statusTrue (1) if the converter diagnostics have passed.
statusFalse (2) will be returned if the converter diagnostics have not passed. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.15 |
||||
|
dm3StatusConvStatemandatory
This OID shows the converter state as defined by the device status register.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.7.3.6.2.2.1.16 |
.1.3.6.1.4.1.318.1.1.7.3.7.1.2
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk dm3StatusOutRlyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::dm3StatusOutRlyTable'
Allows for viewing status of the output relays. The number of entries is contained in the dm3StatusOutRlyTableSize OID.
The output relay to gather status from.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
dm3StatusOutRlyIndexmandatory
The index to the DC powerplant output relay.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.7.3.7.1.2.1.1 |
||||
|
dm3StatusOutRlyNamemandatory
The name of the output relay. The maximum size is
16 characters. The name is set by using the dm3ConfigOutRlyName OID. This OID is provided for informational purposes only. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.7.3.7.1.2.1.2 |
||||
|
dm3StatusOutRlyStatusmandatory
Getting this OID will return statusOn (1) if the output relay is enabled/on.
statusOff (2) will be returned if the output relay is disabled/off. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.7.3.7.1.2.1.3 |
.1.3.6.1.4.1.318.1.1.7.3.7.2.2
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk dm3StatusInRlyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::dm3StatusInRlyTable'
Allows for viewing status of the input relays. The number of entries is contained in the dm3StatusInRlyTableSize OID.
The input relays to gather status from.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
dm3StatusInRlyIndexmandatory
The index to the DC powerplant input relay.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.7.3.7.2.2.1.1 |
||||
|
dm3StatusInRlyNamemandatory
The name of the input relay. The maximum size is
16 characters. The name is set by using the dm3ConfigInRlyName OID. This OID is provided for informational purposes only. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.7.3.7.2.2.1.2 |
||||
|
dm3StatusInRlyStatusmandatory
Getting this OID will return statusOn (1) if the input relay is enabled/on.
statusOff (2) will be returned if the input relay is disabled/off. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.7.3.7.2.2.1.3 |
.1.3.6.1.4.1.318.1.1.7.3.8.1.2
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk dm3StatusBreakersTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::dm3StatusBreakersTable'
Allows for viewing status of the circuit breakers. The number of entries is contained in the dm3StatusBreakersTableSize OID.
The circuit breaker to gather status from.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
dm3StatusBreakersIndexmandatory
The index to the DC powerplant circuit breaker.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.7.3.8.1.2.1.1 |
||||
|
dm3StatusBreakersNamemandatory
The name of the circuit breaker. The maximum size is
16 characters. The name is set by using the dm3ConfigBreakersName OID. This OID is provided for informational purposes only. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.7.3.8.1.2.1.2 |
||||
|
dm3StatusBreakersStatusmandatory
Getting this OID will return statusClosed (1) if the circuit breaker is closed.
statusOpen (2) will be returned if the circuit breaker is open. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.7.3.8.1.2.1.3 |
.1.3.6.1.4.1.318.1.1.7.3.8.2.2
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk dm3StatusFusesTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::dm3StatusFusesTable'
Allows for viewing status of the fuses. The number of entries is contained in the dm3StatusFusesTableSize OID.
The fuse to gather status from.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
dm3StatusFusesIndexmandatory
The index to the DC powerplant fuse.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.7.3.8.2.2.1.1 |
||||
|
dm3StatusFusesNamemandatory
The name of the fuse. The maximum size is
16 characters. The name is set by using the dm3ConfigFuseName OID. This OID is provided for informational purposes only. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.7.3.8.2.2.1.2 |
||||
|
dm3StatusFusesStatusmandatory
Getting this OID will return statusClosed (1) if the fuse is closed.
statusOpen (2) will be returned if the fuse is open. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.7.3.8.2.2.1.3 |
.1.3.6.1.4.1.318.1.1.8.2.1.3
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk atsCalibrationInputPhaseTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::atsCalibrationInputPhaseTable'
The number of phases per input line to this device. It is not applicable to AP44xxA units or newer.
An entry containing calibration information applicable to a
particular input phase. It is not applicable to AP44xxA units or newer.
particular input phase. It is not applicable to AP44xxA units or newer.
| Column | Syntax | OID |
|---|---|---|
|
atsCalibrationInputTableIndexmandatory
The input identifier. It is not applicable to AP44xxA units or newer.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.2.1.3.1.1 |
|
atsCalibrationInputPhaseTableIndexmandatory
The input phase identifier. It is not applicable to AP44xxA units or newer.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.2.1.3.1.2 |
|
atsLineVoltageCalibrationFactormandatory
The Line Voltage Calibration factor. This value is set at the factory.
It is not applicable to AP44xxA units or newer. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.2.1.3.1.3 |
.1.3.6.1.4.1.318.1.1.8.2.2.2
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk atsCalibrationPowerSupplyVoltageTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::atsCalibrationPowerSupplyVoltageTable'
A list of Power Supply table entries. It is not applicable to AP44xxA units or newer.
An entry containing information applicable to a particular
Power Supply Voltage. It is not applicable to AP44xxA units or newer.
Power Supply Voltage. It is not applicable to AP44xxA units or newer.
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
The power supply voltage identifier. It is not applicable to AP44xxA units or newer.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.2.2.2.1.1 |
||||||||||
|
atsCalibrationPowerSupplyVoltagemandatory
This value describes the power supply voltage of
24V Source A, 24V Source B, +12V, -12V and 5V. It is not applicable to AP44xxA units or newer. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.8.2.2.2.1.2 |
||||||||||
|
The Line Voltage Calibration factor. This value is set at the factory.
It is not applicable to AP44xxA units or newer. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.2.2.2.1.3 |
.1.3.6.1.4.1.318.1.1.8.2.2.3
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk ats4gCalibrationPowerSupplyVoltageTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::ats4gCalibrationPowerSupplyVoltageTable'
A list of Power Supply table entries. It is applicable only to AP44xx units.
An entry containing information applicable to a particular
Power Supply Voltage. It is applicable only to AP44xx ATS units.
Power Supply Voltage. It is applicable only to AP44xx ATS units.
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
The power supply voltage identifier. It is applicable only to AP44xx ATS units.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.2.2.3.1.1 |
||||||||||||
|
ats4gCalibrationPowerSupplyVoltagemandatory
This value describes the power supply voltage of
24V Source A, 24V Source B, VBoost Source A, VBoost Source B, 3.3V, 1.0V. It is applicable only to AP44xx units. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.8.2.2.3.1.2 |
||||||||||||
|
The Line Voltage Calibration factor. This value is set at the factory.
It is applicable only to AP44xx units. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.2.2.3.1.3 |
.1.3.6.1.4.1.318.1.1.8.2.3.3
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk atsCalibrationOutputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::atsCalibrationOutputTable'
A list of output table entries. It is not applicable to AP44xxA units or newer.
An entry containing information applicable to a particular output.
It is not applicable to AP44xxA units or newer.
It is not applicable to AP44xxA units or newer.
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
atsCalibrationOutputTableIndexmandatory
The output identifier. It is not applicable to AP44xxA units or newer.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.2.3.3.1.1 |
||||||||
|
atsCalibrationOutputPhasesTableIndexmandatory
Description of each calibration factor for each
output phase utilized in this device and one for neutral. It is not applicable to AP44xxA units or newer. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.8.2.3.3.1.2 |
||||||||
|
atsOutputCurrentCalibrationFactormandatory
The output current calibration factor. It is not applicable to AP44xxA units or newer.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.2.3.3.1.3 |
.1.3.6.1.4.1.318.1.1.8.4.14
·
1 row entry
·
5 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk atsConfigBankTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::atsConfigBankTable'
Allows for configuration of each ATS bank.
This gives access to bank current threshold
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
atsConfigBankTableIndexmandatory
An index to the bank table entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.4.14.1.1 |
||||||
|
atsConfigBankmandatory
The bank number of an ATS
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.8.4.14.1.2 |
||||||
|
atsConfigBankLowLoadThresholdmandatory
A threshold that indicates the current drawn is nearing
a low consumption condition. It is represented in Amps. A warning will be issued when the load is less than the threshold value. A threshold value o… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.4.14.1.3 |
||||||
|
atsConfigBankNearOverLoadThresholdmandatory
A threshold that indicates the current drawn is nearing
an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum va… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.4.14.1.4 |
||||||
|
atsConfigBankOverLoadThresholdmandatory
A threshold that indicates the current drawn has entered
an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum v… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.4.14.1.5 |
.1.3.6.1.4.1.318.1.1.8.4.16
·
1 row entry
·
5 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk atsConfigPhaseTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::atsConfigPhaseTable'
Allows for configuration of each ATS phase.
This gives access to phase threshold
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
atsConfigPhaseTableIndexmandatory
The index to the phase table entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.4.16.1.1 |
||||||
|
atsConfigPhasemandatory
The phase number of an ATS
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.8.4.16.1.2 |
||||||
|
atsConfigPhaseLowLoadThresholdmandatory
A threshold that indicates the current drawn is nearing
a low consumption condition. It is represented in Amps. A warning will be issued when the load is less than the threshold value. A threshold value o… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.4.16.1.3 |
||||||
|
atsConfigPhaseNearOverLoadThresholdmandatory
A threshold that indicates the current drawn is nearing
an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum va… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.4.16.1.4 |
||||||
|
atsConfigPhaseOverLoadThresholdmandatory
A threshold that indicates the current drawn has entered
an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. Minimum v… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.4.16.1.5 |
.1.3.6.1.4.1.318.1.1.8.5.3.2
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk atsInputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::atsInputTable'
A list of input table entries. The number of entries is given by the value of atsNumInputs.
An entry containing information applicable to a
particular input.
particular input.
Indexes
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
atsInputTableIndexmandatory
The input identifier.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.3.2.1.1 |
||||||||||
|
atsNumInputPhasesmandatory
The number of input phases utilized in this
device. The sum of all the atsNumInputPhases variable indicates the number of rows in the input phase table. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.3.2.1.2 |
||||||||||
|
atsInputVoltageOrientationmandatory
The input voltage orientation:
1: unknown for this Source 2: singlePhase - phase 1 voltage is between Phase 1 and Neutral. 3: splitPhase - phase 1 voltage is between Phase 1 and Neutral; phase 2 voltage is between Phase… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.8.5.3.2.1.3 |
||||||||||
|
atsInputFrequencymandatory
The input frequency in Hertz, or -1 if it's unsupported
by this Source. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.3.2.1.4 |
||||||||||
|
atsInputTypemandatory
The input type.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.8.5.3.2.1.5 |
||||||||||
|
atsInputNamemandatory
A name given to a particular input.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.8.5.3.2.1.6 |
.1.3.6.1.4.1.318.1.1.8.5.3.3
·
1 row entry
·
11 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk atsInputPhaseTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::atsInputPhaseTable'
A list of input table entries. The number of entries is given by the sum of the atsNumInputPhases.
An entry containing information applicable to a
particular input phase.
particular input phase.
| Column | Syntax | OID |
|---|---|---|
|
atsInputPhaseTableIndexmandatory
The input identifier.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.3.3.1.1 |
|
atsInputPhaseIndexmandatory
The input phase identifier.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.3.3.1.2 |
|
atsInputVoltagemandatory
The input voltage in VAC, or -1 if it's unsupported
by this Source. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.3.3.1.3 |
|
atsInputMaxVoltagemandatory
The maximum input voltage in VAC measured
since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.3.3.1.4 |
|
atsInputMinVoltagemandatory
The minimum input voltage in VAC measured
since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.3.3.1.5 |
|
atsInputCurrentmandatory
The input current in amperes, or -1 if it's
unsupported by this Source. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.3.3.1.6 |
|
atsInputMaxCurrentmandatory
The maximum input current in amperes measured
since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.3.3.1.7 |
|
atsInputMinCurrentmandatory
The minimum input current in amperes measured
since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.3.3.1.8 |
|
atsInputPowermandatory
The input power in Watts, or -1 if it's unsupported
by this Source. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.3.3.1.9 |
|
atsInputMaxPowermandatory
The maximum input power in Watts measured
since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.3.3.1.10 |
|
atsInputMinPowermandatory
The minimum input power in Watts measured
since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.3.3.1.11 |
.1.3.6.1.4.1.318.1.1.8.5.4.2
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk atsOutputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::atsOutputTable'
A list of output table entries. The number of entries is given by the value of atsOutputNumPhases.
An entry containing information applicable to a
particular output.
particular output.
Indexes
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
atsOutputTableIndexmandatory
The output identifier.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.4.2.1.1 |
||||||||||
|
atsNumOutputPhasesmandatory
The number of output phases utilized in this
device. The sum of all the atsNumOutputPhases variable indicates the number of rows in the output phase table. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.4.2.1.2 |
||||||||||
|
atsOutputVoltageOrientationmandatory
The output voltage orientation:
1: unknown for this ATS 2: singlePhase - phase 1 voltage is between Phase 1 and Neutral. 3: splitPhase - phase 1 voltage is between Phase 1 and Neutral; phase 2 voltage is between Phase 2… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.8.5.4.2.1.3 |
||||||||||
|
atsOutputFrequencymandatory
The output frequency in Hertz, or -1 if it's
unsupported by this ATS. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.4.2.1.4 |
.1.3.6.1.4.1.318.1.1.8.5.4.3
·
1 row entry
·
19 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk atsOutputPhaseTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::atsOutputPhaseTable'
A list of output table entries. The number of entries is given by the sum of the atsNumOutputPhases.
An entry containing information applicable to a
particular output phase.
particular output phase.
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
atsOutputPhaseTableIndexmandatory
The output identifier.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.4.3.1.1 |
||||||||
|
atsOutputPhaseIndexmandatory
Description of each output phase utilized in
this device and one for neutral. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.8.5.4.3.1.2 |
||||||||
|
atsOutputVoltagemandatory
The output voltage in VAC, or -1 if it's unsupported
by this ATS. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.4.3.1.3 |
||||||||
|
atsOutputCurrentmandatory
The output current in 0.1 amperes drawn
by the load on the ATS, or -1 if it's unsupported by this ATS. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.4.3.1.4 |
||||||||
|
atsOutputMaxCurrentmandatory
The maximum output current in 0.1 amperes measured
since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.4.3.1.5 |
||||||||
|
atsOutputMinCurrentmandatory
The minimum output current in 0.1 amperes measured
since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.4.3.1.6 |
||||||||
|
atsOutputLoadmandatory
The output load in VA, or -1 if it's unsupported
by this ATS. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.4.3.1.7 |
||||||||
|
atsOutputMaxLoadmandatory
The maximum output load in VA measured
since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.4.3.1.8 |
||||||||
|
atsOutputMinLoadmandatory
The minimum output load in VA measured
since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.4.3.1.9 |
||||||||
|
atsOutputPercentLoadmandatory
The percentage of the ATS load capacity in VA at
redundancy @ (n + x) presently being used on this output phase, or -1 if it's unsupported by this ATS. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.4.3.1.10 |
||||||||
|
atsOutputMaxPercentLoadmandatory
The maximum percentage of the ATS load capacity in
VA measured at redundancy @ (n + x) presently being used on this output phase since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns … |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.4.3.1.11 |
||||||||
|
atsOutputMinPercentLoadmandatory
The minimum percentage of the ATS load capacity in
VA measured at redundancy @ (n + x) presently being used on this output phase since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns … |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.4.3.1.12 |
||||||||
|
atsOutputPowermandatory
The output apparent power in VA, or
-1 if it's unsupported by this ATS. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.4.3.1.13 |
||||||||
|
atsOutputMaxPowermandatory
The maximum output power in VAs measured
since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.4.3.1.14 |
||||||||
|
atsOutputMinPowermandatory
The minimum output power in VA measured
since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.4.3.1.15 |
||||||||
|
atsOutputPercentPowermandatory
The percentage of the ATSpower capacity in VA at
redundancy @ (n + x) presently being used on this output phase, or -1 if it's unsupported by this ATS. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.4.3.1.16 |
||||||||
|
atsOutputMaxPercentPowermandatory
The maximum percentage of the ATSpower capacity
in VA measured at redundancy @ (n + x) presently being used on this output phase since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns … |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.4.3.1.17 |
||||||||
|
atsOutputMinPercentPowermandatory
The minimum percentage of the ATSpower capacity
in VA measured at redundancy @ (n + x) presently being used on this output phase since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns … |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.4.3.1.18 |
||||||||
|
atsOutputPhaseStatemandatory
Getting this OID will return the phase load state.
normal(1) indicates that the bank is operating properly within the atsConfigPhaseLowLoadThreshold and atsConfigPhaseNearOverLoadThreshold OID values. … |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.8.5.4.3.1.19 |
.1.3.6.1.4.1.318.1.1.8.5.4.5
·
1 row entry
·
20 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk atsOutputBankTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::atsOutputBankTable'
Allows for getting table entries.
This gives access to bank table entries
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
atsOutputBankTableIndexmandatory
The index to the bank table entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.4.5.1.1 |
||||||||
|
atsOutputPhasemandatory
The phase number of an ATS
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.8.5.4.5.1.2 |
||||||||
|
atsOutputBankmandatory
The bank number of an ATS
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.8.5.4.5.1.3 |
||||||||
|
atsOutputBankCurrentmandatory
Getting this OID will return the bank current measured
in tenths of Amps. |
RFC1155-SMIGauge Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.318.1.1.8.5.4.5.1.4 |
||||||||
|
atsOutputBankStatemandatory
Getting this OID will return the bank load state.
normal(1) indicates that the bank is operating properly within the atsConfigBankLowLoadThreshold and atsConfigBankNearOverLoadThreshold OID values. … |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.8.5.4.5.1.5 |
||||||||
|
atsOutputBankOutputVoltagemandatory
The output voltage in VAC, or -1 if it's unsupported
by this ATS. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.4.5.1.6 |
||||||||
|
atsOutputBankMaxCurrentmandatory
The maximum output current, on the bank represented by
OID atsOutputBank, in 0.1 amperes measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.4.5.1.7 |
||||||||
|
atsOutputBankMinCurrentmandatory
The minimum output current, on the bank represented by
OID atsOutputBank, in 0.1 amperes measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.4.5.1.8 |
||||||||
|
atsOutputBankLoadmandatory
The output load, on the bank represented by
OID atsOutputBank, in VA, or -1 if it's unsupported by this ATS. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.4.5.1.9 |
||||||||
|
atsOutputBankMaxLoadmandatory
The maximum output load, on the bank represented by
OID atsOutputBank, in VA measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.4.5.1.10 |
||||||||
|
atsOutputBankMinLoadmandatory
The minimum output load, on the bank represented by
OID atsOutputBank, in VA measured since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.4.5.1.11 |
||||||||
|
atsOutputBankPercentLoadmandatory
The percentage of the ATS load capacity in VA at
redundancy @ (n + x) presently being used on this bank, represented by OID atsOutputBank. Returns (-1) if unsupported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.4.5.1.12 |
||||||||
|
atsOutputBankMaxPercentLoadmandatory
The maximum percentage of the ATS load capacity in
VA measured at redundancy @ (n + x) presently being used on this bank, represented by OID atsOutputBank, since the last time this variable was read or reset (atsStatusR… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.4.5.1.13 |
||||||||
|
atsOutputBankMinPercentLoadmandatory
The minimum percentage of the ATS load capacity in
VA measured at redundancy @ (n + x) presently being used on this bank, represented by OID atsOutputBank, since the last time this variable was read or reset (atsStatusR… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.4.5.1.14 |
||||||||
|
atsOutputBankPowermandatory
The output apparent power in VA on the bank represented by
OID atsOutputBank or -1 if it's unsupported by this ATS. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.4.5.1.15 |
||||||||
|
atsOutputBankMaxPowermandatory
The maximum output power in VA measured on the bank
represented by OID atsOutputBank since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.4.5.1.16 |
||||||||
|
atsOutputBankMinPowermandatory
The minimum output power in VA measured on the bank
represented by OID atsOutputBank since the last time this variable was read or reset (atsStatusResetMaxMinValues). Returns (-1) if unsupported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.4.5.1.17 |
||||||||
|
atsOutputBankPercentPowermandatory
The percentage of the ATSpower capacity in Watts at
redundancy @ (n + x) presently being used on this bank, represented by OID atsOutputBank, or -1 if it's unsupported by this ATS. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.4.5.1.18 |
||||||||
|
atsOutputBankMaxPercentPowermandatory
The maximum percentage of the ATSpower capacity
in VA measured at redundancy @ (n + x) presently being used on this bank, represented by OID atsOutputBank, since the last time this variable was read or reset (atsStatusR… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.4.5.1.19 |
||||||||
|
atsOutputBankMinPercentPowermandatory
The minimum percentage of the ATSpower capacity
in VA measured at redundancy @ (n + x) presently being used on this bank, represented by OID atsOutputBank since the last time this variable was read or reset (atsStatusRe… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.8.5.4.5.1.20 |
.1.3.6.1.4.1.318.1.1.9.3.3.2
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk dcmim2ConfigLVDTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::dcmim2ConfigLVDTable'
Allows for accessing settings of the LVDs. The number of entries is contained in the dcmim2ConfigLVDTableSize OID.
The LVD to configure.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
dcmim2ConfigLVDIndexmandatory
The index to the DC powerplant LVD.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.9.3.3.2.1.1 |
||||
|
dcmim2ConfigLVDTripmandatory
LVD Trip threshold. System bus voltage at which LVD will trip (open)
during a battery backup operation. Values are represented in thousandths of Volts (mV). |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.9.3.3.2.1.2 |
||||
|
dcmim2ConfigLVDResetmandatory
LVD Reset threshold. System bus voltage at which LVD will reset (close)
after AC power has been restored. Values are represented in thousandths of Volts (mV). |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.9.3.3.2.1.3 |
||||
|
dcmim2ConfigLVDStatemandatory
Getting this OID will return statusClosed (1) if the LVD is closed.
statusOpened (2) will be returned if the LVD is opened. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.9.3.3.2.1.4 |
.1.3.6.1.4.1.318.1.1.9.4.2.2
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk dcmim2StatusRectTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::dcmim2StatusRectTable'
Allows for accessing settings of the rectifiers. The number of entries is contained in the dcmim2StatusRectTableSize OID.
The rectifier to gather status from.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
dcmim2StatusRectIndexmandatory
The index to the DC powerplant rectifier.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.9.4.2.2.1.1 |
||||
|
dcmim2StatusRectDevTypemandatory
This OID shows the rectifier device type.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.9.4.2.2.1.2 |
||||
|
dcmim2StatusRectIDmandatory
This OID shows the rectifier ID. This enumerates the number of the rectifier within
a group of rectifiers. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.9.4.2.2.1.3 |
||||
|
dcmim2StatusRectPhyAddrmandatory
This OID shows the rectifier physical address (the address on the bus).
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.9.4.2.2.1.4 |
||||
|
dcmim2StatusRectFailmandatory
Getting this OID will return statusTrue (1) if the rectifier has failed.
statusFalse (2) will be returned if the rectifier has not failed. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.9.4.2.2.1.5 |
||||
|
dcmim2StatusRectCurrentmandatory
This OID shows the individual rectifier current in thousandths of Amps (mA).
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.9.4.2.2.1.6 |
.1.3.6.1.4.1.318.1.1.9.4.4.2
·
1 row entry
·
2 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk dcmim2StatusLVDTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::dcmim2StatusLVDTable'
Allows for accessing the LVDs. The number of entries is contained in the dcmim2StatusLVDTableSize OID.
The LVD to access.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
dcmim2StatusLVDIndexmandatory
The index to the DC powerplant LVD.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.9.4.4.2.1.1 |
||||
|
dcmim2StatusLVDStatemandatory
Getting this OID will return statusClosed (1) if the LVD is closed.
statusOpened (2) will be returned if the LVD is opened. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.9.4.4.2.1.2 |
.1.3.6.1.4.1.318.1.1.9.4.5.2
·
1 row entry
·
2 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk dcmim2StatusAlarmsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::dcmim2StatusAlarmsTable'
Allows for accessing system alarms. The number of entries is contained in the dcmim2StatusAlarmsTableSize OID.
The alarm to display.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
dcmim2StatusAlarmsIndexmandatory
The index of the system alarm.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.9.4.5.2.1.1 |
|
dcmim2StatusAlarmsTextmandatory
The 16 character text describing the active alarm condition.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.9.4.5.2.1.2 |
.1.3.6.1.4.1.318.1.1.10.1.2.2
·
1 row entry
·
22 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk emConfigProbesTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::emConfigProbesTable'
A list of probes supported by the Environmental Monitor and their configurations.
The Environmental Monitor probe configurations.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
emConfigProbeNumbermandatory
The index into an Environmental Monitor probe entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.1.2.2.1.1 |
||||
|
emConfigProbeNamemandatory
A descriptive name of the probe set by the user,
possibly denoting its location or purpose. |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.1.2.2.1.2 |
||||
|
emConfigProbeHighTempThresholdmandatory
The high temperature alarm threshold for the probe.
Units are displayed in the scale selected in the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit). |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.1.2.2.1.3 |
||||
|
emConfigProbeLowTempThresholdmandatory
The low temperature alarm threshold for the probe.
Units are displayed in the scale selected in the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit). |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.1.2.2.1.4 |
||||
|
emConfigProbeTempUnitsmandatory
The temperature scale used to display the temperature
thresholds of the probe, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences configuration in the agent. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.1.2.2.1.5 |
||||
|
emConfigProbeHighHumidThresholdmandatory
The high humidity alarm threshold for the probe in
percent relative humidity. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.1.2.2.1.6 |
||||
|
emConfigProbeLowHumidThresholdmandatory
The low humidity alarm threshold for the probe in
percent relative humidity. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.1.2.2.1.7 |
||||
|
emConfigProbeHighTempEnablemandatory
The high temperature alarm enable/disable for the
probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.1.2.2.1.8 |
||||
|
emConfigProbeLowTempEnablemandatory
The low temperature alarm enable/disable for the
probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.1.2.2.1.9 |
||||
|
emConfigProbeHighHumidEnablemandatory
The high humidity alarm enable/disable for the
probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.1.2.2.1.10 |
||||
|
emConfigProbeLowHumidEnablemandatory
The low humidity alarm enable/disable for the
probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.1.2.2.1.11 |
||||
|
emConfigProbeMaxTempThresholdmandatory
The maximum temperature alarm threshold for the probe.
Units are displayed in the scale selected in the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit). |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.1.2.2.1.12 |
||||
|
emConfigProbeMinTempThresholdmandatory
The minimum temperature alarm threshold for the probe.
Units are displayed in the scale selected in the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit). |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.1.2.2.1.13 |
||||
|
emConfigProbeMaxHumidThresholdmandatory
The maximun humidity alarm threshold for the probe in
percent relative humidity. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.1.2.2.1.14 |
||||
|
emConfigProbeMinHumidThresholdmandatory
The minimum humidity alarm threshold for the probe in
percent relative humidity. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.1.2.2.1.15 |
||||
|
emConfigProbeMaxTempEnablemandatory
The maximum temperature alarm enable/disable for the
probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been viola… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.1.2.2.1.16 |
||||
|
emConfigProbeMinTempEnablemandatory
The minimum temperature alarm enable/disable for the
probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been viola… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.1.2.2.1.17 |
||||
|
emConfigProbeMaxHumidEnablemandatory
The maximum humidity alarm enable/disable for the
probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.1.2.2.1.18 |
||||
|
emConfigProbeMinHumidEnablemandatory
The minimum humidity alarm enable/disable for the
probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.1.2.2.1.19 |
||||
|
emConfigProbeTempHysteresismandatory
The number of degrees beyond the temperature thresholds
at which an active temperature alarm will be cleared. This configuration setting applies to all temperature thresholds. Units are displayed in the scale selected i… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.1.2.2.1.20 |
||||
|
emConfigProbeHumidHysteresismandatory
The number of percent RH points beyond the humidity
thresholds at which an active humidity alarm will be cleared. This configuration setting applies to all humidity thresholds. Units are displayed in the scale selected … |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.1.2.2.1.21 |
||||
|
emConfigProbeLocationmandatory
A string describing the location of the probe.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.1.2.2.1.22 |
.1.3.6.1.4.1.318.1.1.10.1.2.4
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk emConfigContactsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::emConfigContactsTable'
A list of contacts supported by the Environmental Monitor and their configurations.
The Environmental Monitor contact configurations.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
emConfigContactNumbermandatory
The index of an Environmental Monitor contact.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.1.2.4.1.1 |
||||||
|
emConfigContactNamemandatory
A descriptive name for an Environmental Monitor
contact set by the user, possibly denoting its location or purpose. |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.1.2.4.1.2 |
||||||
|
emConfigContactEnablemandatory
An Environmental Monitor contact alarm enable/disable.
No alarm will be generated if the contact is disabled(1). An alarm will be generated if the contact is enabled(2) and the contact has been faulted. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.1.2.4.1.3 |
||||||
|
emConfigContactSeveritymandatory
The severity of the alarm that will be triggered when
the input contact is activated. The alarms can be critical(1), warning(2) or informational(3). |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.1.2.4.1.4 |
||||||
|
emConfigContactNormalStatemandatory
The contact state that will be considered normal, i.e.
will not trigger an alarm. The states are open(1) or closed(2). |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.1.2.4.1.5 |
||||||
|
emConfigContactLocationmandatory
A descriptive label for the contact denoting its
location or purpose. |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.1.2.4.1.6 |
.1.3.6.1.4.1.318.1.1.10.1.3.3
·
1 row entry
·
14 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk emStatusProbesTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::emStatusProbesTable'
A list of probes supported by the Environmental Monitor and their status.
The status of the probe.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
emStatusProbeNumbermandatory
The index of the probe.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.1.3.3.1.1 |
||||||
|
emStatusProbeNamemandatory
A descriptive name for the probe set by the user,
possibly denoting its location or purpose. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.1.3.3.1.2 |
||||||
|
emStatusProbeStatusmandatory
The connected status of the probe, either
disconnected(1) or connected(2). |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.1.3.3.1.3 |
||||||
|
emStatusProbeCurrentTempmandatory
The current temperature reading from the probe displayed
in the units shown in the 'emStatusProbeTempUnits' OID (Celsius or Fahrenheit). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.1.3.3.1.4 |
||||||
|
emStatusProbeTempUnitsmandatory
The temperature scale used to display the temperature
thresholds of the probe, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences configuration in the agent. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.1.3.3.1.5 |
||||||
|
emStatusProbeCurrentHumidmandatory
The current humidity reading from the probe in
percent relative humidity. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.1.3.3.1.6 |
||||||
|
emStatusProbeHighTempViolationmandatory
The high temperature violation status of the probe
temperature reading. This OID will show a highTempViolation(2) if the current temperature reading shown in the 'emStatusProbeCurrentTemp' OID is greater than or equal t… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.1.3.3.1.7 |
||||||
|
emStatusProbeLowTempViolationmandatory
The high temperature violation status of the probe
temperature reading. This OID will show a lowTempViolation(2) if the current temperature reading shown in the 'emStatusProbeCurrentTemp' OID is less than or equal to th… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.1.3.3.1.8 |
||||||
|
emStatusProbeHighHumidViolationmandatory
The high humidity violation status of the probe humidity
reading. This OID will show a highTempViolation(2) if the current humidity reading shown in the 'emStatusProbeCurrentHumid' OID is greater than or equal to the hi… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.1.3.3.1.9 |
||||||
|
emStatusProbeLowHumidViolationmandatory
The low humidity violation status of the probe humidity
reading. This OID will show a lowTempViolation(2) if the current humidity reading shown in the 'emStatusProbeCurrentHumid' OID is less than or equal to the low hum… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.1.3.3.1.10 |
||||||
|
emStatusProbeMaxTempViolationmandatory
The max temperature violation status of the probe
temperature reading. This OID will show a maxTempViolation(2) if the current temperature reading shown in the 'emStatusProbeCurrentTemp' OID is greater than or equal to … |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.1.3.3.1.11 |
||||||
|
emStatusProbeMinTempViolationmandatory
The minimum temperature violation status of the probe
temperature reading. This OID will show a minTempViolation(2) if the current temperature reading shown in the 'emStatusProbeCurrentTemp' OID is less than or equal to… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.1.3.3.1.12 |
||||||
|
emStatusProbeMaxHumidViolationmandatory
The maximum humidity violation status of the probe humidity
reading. This OID will show a maxTempViolation(2) if the current humidity reading shown in the 'emStatusProbeCurrentHumid' OID is greater than or equal to the … |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.1.3.3.1.13 |
||||||
|
emStatusProbeMinHumidViolationmandatory
The minimum humidity violation status of the probe humidity
reading. This OID will show a minTempViolation(2) if the current humidity reading shown in the 'emStatusProbeCurrentHumid' OID is less than or equal to the min… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.1.3.3.1.14 |
.1.3.6.1.4.1.318.1.1.10.1.3.5
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk emStatusContactsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::emStatusContactsTable'
A list of contacts supported by the Environmental Monitor and their status.
The status of the contact.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
emStatusContactNumbermandatory
The index of the Environmental Monitor contact.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.1.3.5.1.1 |
||||||
|
emStatusContactNamemandatory
A descriptive name for the Environmental Monitor contact
set by the user, possibly denoting its location or purpose. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.1.3.5.1.2 |
||||||
|
emStatusContactStatusmandatory
The status of the Environmental Monitor contact. The status
will show noFault(1) if the contact is in the normal state and the 'emConfigContactEnable' OID is enabled. The status will show a fault(2) if the contact is fa… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.1.3.5.1.3 |
.1.3.6.1.4.1.318.1.1.10.2.2.2
·
1 row entry
·
22 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk iemConfigProbesTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::iemConfigProbesTable'
A list of probes supported by the Environmental Monitor and their configurations.
The Environmental Monitor probe configurations.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
iemConfigProbeNumbermandatory
The index to a Environmental Monitor probe entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.2.2.2.1.1 |
||||
|
iemConfigProbeNamemandatory
A descriptive name for the probe set by the user,
possibly denoting its location or purpose. |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.2.2.2.1.2 |
||||
|
iemConfigProbeHighTempThresholdmandatory
The high temperature alarm threshold for the probe.
Units are displayed in the scale selected in the 'iemConfigProbeTempUnits' OID (Celsius or Fahrenheit). |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.2.2.2.1.3 |
||||
|
iemConfigProbeLowTempThresholdmandatory
The low temperature alarm threshold for the probe.
Units are displayed in the scale selected in the 'iemConfigProbeTempUnits' OID (Celsius or Fahrenheit). |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.2.2.2.1.4 |
||||
|
iemConfigProbeTempUnitsmandatory
The temperature scale used to display the temperature
thresholds of the probe, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences configuration in the agent. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.2.2.2.1.5 |
||||
|
iemConfigProbeHighHumidThresholdmandatory
The high humidity alarm threshold for the probe in
percent relative humidity. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.2.2.2.1.6 |
||||
|
iemConfigProbeLowHumidThresholdmandatory
The low humidity alarm threshold for the probe in
percent relative humidity. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.2.2.2.1.7 |
||||
|
iemConfigProbeHighTempEnablemandatory
The high temperature alarm enable/disable for the
probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.2.2.2.1.8 |
||||
|
iemConfigProbeLowTempEnablemandatory
The low temperature alarm enable/disable for the
probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.2.2.2.1.9 |
||||
|
iemConfigProbeHighHumidEnablemandatory
The high humidity alarm enable/disable for the
probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.2.2.2.1.10 |
||||
|
iemConfigProbeLowHumidEnablemandatory
The low humidity alarm enable/disable for the
probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.2.2.2.1.11 |
||||
|
iemConfigProbeMaxTempThresholdmandatory
The maximun temperature alarm threshold for the probe.
Units are displayed in the scale selected in the 'iemConfigProbeTempUnits' OID (Celsius or Fahrenheit). |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.2.2.2.1.12 |
||||
|
iemConfigProbeMinTempThresholdmandatory
The minimun temperature alarm threshold for the probe.
Units are displayed in the scale selected in the 'iemConfigProbeTempUnits' OID (Celsius or Fahrenheit). |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.2.2.2.1.13 |
||||
|
iemConfigProbeMaxHumidThresholdmandatory
The maximum humidity alarm threshold for the probe in
percent relative humidity. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.2.2.2.1.14 |
||||
|
iemConfigProbeMinHumidThresholdmandatory
The minimum humidity alarm threshold for the probe in
percent relative humidity. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.2.2.2.1.15 |
||||
|
iemConfigProbeMaxTempEnablemandatory
The maximum temperature alarm enable/disable for the
probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been viola… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.2.2.2.1.16 |
||||
|
iemConfigProbeMinTempEnablemandatory
The low temperature alarm enable/disable for the
probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.2.2.2.1.17 |
||||
|
iemConfigProbeMaxHumidEnablemandatory
The maximum humidity alarm enable/disable for the
probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.2.2.2.1.18 |
||||
|
iemConfigProbeMinHumidEnablemandatory
The minimum humidity alarm enable/disable for the
probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.2.2.2.1.19 |
||||
|
iemConfigProbeTempHysteresismandatory
The number of degrees beyond the temperature thresholds
at which an active temperature alarm will be cleared. This configuration setting applies to all temperature thresholds. Units are displayed in the scale selected i… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.2.2.2.1.20 |
||||
|
iemConfigProbeHumidHysteresismandatory
The number of percent RH points beyond the humidity
thresholds at which an active humidity alarm will be cleared. This configuration setting applies to all humidity thresholds. Units are displayed in the scale selected … |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.2.2.2.1.21 |
||||
|
iemConfigProbeLocationmandatory
A string describing the location of the probe.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.2.2.2.1.22 |
.1.3.6.1.4.1.318.1.1.10.2.2.4
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk iemConfigContactsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::iemConfigContactsTable'
A list of contacts supported by the Environmental Monitor and their configurations.
The Environmental Monitor contact configurations.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
iemConfigContactNumbermandatory
The index of an Environmental Monitor contact.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.2.2.4.1.1 |
||||||
|
iemConfigContactNamemandatory
A descriptive name for the Environmental Monitor contact
set by the user, possibly denoting its location or purpose. |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.2.2.4.1.2 |
||||||
|
iemConfigContactEnablemandatory
An Environmental Monitor contact alarm enable/disable.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.2.2.4.1.3 |
||||||
|
iemConfigContactSeveritymandatory
The severtity of the alarm that will be triggered when
the input contact is activated. The alarms can be critical(1), warning(2) or informational(3). NOTE: informational(3) is deprecated (and no longer valid) for this O… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.2.2.4.1.4 |
||||||
|
iemConfigContactNormalStatemandatory
The contact state that will be considered normal, i.e.
will not trigger an alarm. The states are open(1) or closed(2). |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.2.2.4.1.5 |
||||||
|
iemConfigContactLocationmandatory
A descriptive label for the contact denoting its
location or purpose. |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.2.2.4.1.6 |
.1.3.6.1.4.1.318.1.1.10.2.2.6
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk iemConfigRelaysTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::iemConfigRelaysTable'
A list of output relays supported by the Environmental Monitor and their configurations.
The Environmental Monitor output relay configurations.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
iemConfigRelayNumbermandatory
The index of an Environmental Monitor output relay.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.2.2.6.1.1 |
||||
|
iemConfigRelayNamemandatory
A descriptive name of an Environmental Monitor output relay,
set by the user, describing its location or purpose. |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.2.2.6.1.2 |
||||
|
iemConfigRelayNormalStatemandatory
The normal state (non-fault state) of an Environmental
Monitor output relay, either open(1) or closed(2). |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.2.2.6.1.3 |
||||
|
iemConfigRelayFaultConditionmandatory
The fault condition used to activate the output relay.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.2.2.6.1.4 |
.1.3.6.1.4.1.318.1.1.10.2.3.2
·
1 row entry
·
15 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk iemStatusProbesTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::iemStatusProbesTable'
A list of probes supported by the Environmental Monitor and their status.
The status of the probe.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
iemStatusProbeNumbermandatory
The index of the probe.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.2.3.2.1.1 |
||||||
|
iemStatusProbeNamemandatory
A descriptive name for the probe set by the user.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.2.3.2.1.2 |
||||||
|
iemStatusProbeStatusmandatory
The connected status of the probe, either
disconnected(1) or connected(2). |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.2.3.2.1.3 |
||||||
|
iemStatusProbeCurrentTempmandatory
The current temperature reading from the probe displayed
in the units shown in the 'iemStatusProbeTempUnits' OID (Celsius or Fahrenheit). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.2.3.2.1.4 |
||||||
|
iemStatusProbeTempUnitsmandatory
The temperature scale used to display the temperature
thresholds of the probe, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences configuration in the agent. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.2.3.2.1.5 |
||||||
|
iemStatusProbeCurrentHumidmandatory
The current humidity reading from the probe in percent
relative humidity. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.2.3.2.1.6 |
||||||
|
iemStatusProbeHighTempViolationmandatory
The high temperature violation status of the probe
temperature reading. This OID will show a highTempViolation(2) if the current temperature reading shown in the 'iemStatusProbeCurrentTemp' OID is greater than or equal … |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.2.3.2.1.7 |
||||||
|
iemStatusProbeLowTempViolationmandatory
The high temperature violation status of the probe
temperature reading. This OID will show a lowTempViolation(2) if the current temperature reading shown in the 'iemStatusProbeCurrentTemp' OID is less than or equal to t… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.2.3.2.1.8 |
||||||
|
iemStatusProbeHighHumidViolationmandatory
The high humidity violation status of the probe humidity
reading. This OID will show a highTempViolation(2) if the current humidity reading shown in the 'iemStatusProbeCurrentHumid' OID is greater than or equal to the h… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.2.3.2.1.9 |
||||||
|
iemStatusProbeLowHumidViolationmandatory
The low humidity violation status of the probe humidity
reading. This OID will show a lowTempViolation(2) if the current humidity reading shown in the 'iemStatusProbeCurrentHumid' OID is less than or equal to the low hu… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.2.3.2.1.10 |
||||||
|
iemStatusProbeMaxTempViolationmandatory
The max temperature violation status of the probe
temperature reading. This OID will show a maxTempViolation(2) if the current temperature reading shown in the 'iemStatusProbeCurrentTemp' OID is greater than or equal to… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.2.3.2.1.11 |
||||||
|
iemStatusProbeMinTempViolationmandatory
The minimum temperature violation status of the probe
temperature reading. This OID will show a minTempViolation(2) if the current temperature reading shown in the 'iemStatusProbeCurrentTemp' OID is less than or equal t… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.2.3.2.1.12 |
||||||
|
iemStatusProbeMaxHumidViolationmandatory
The maximum humidity violation status of the probe humidity
reading. This OID will show a maxTempViolation(2) if the current humidity reading shown in the 'iemStatusProbeCurrentHumid' OID is greater than or equal to the… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.2.3.2.1.13 |
||||||
|
iemStatusProbeMinHumidViolationmandatory
The minimum humidity violation status of the probe humidity
reading. This OID will show a minTempViolation(2) if the current humidity reading shown in the 'iemStatusProbeCurrentHumid' OID is less than or equal to the mi… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.2.3.2.1.14 |
||||||
|
iemStatusProbeLocationmandatory
A descriptive location for the probe set by the user.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.2.3.2.1.15 |
.1.3.6.1.4.1.318.1.1.10.2.3.4
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk iemStatusContactsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::iemStatusContactsTable'
A list of contacts supported by the Environmental Monitor and their status.
The status of the contact.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
iemStatusContactNumbermandatory
The index of the Environmental Monitor contact.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.2.3.4.1.1 |
||||||
|
iemStatusContactNamemandatory
A descriptive name for the Environmental Monitor contact
set by the user, denoting its location or purpose. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.2.3.4.1.2 |
||||||
|
iemStatusContactStatusmandatory
The status of the Environmental Monitor contact. The status
will show noFault(1) if the contact is in the normal state and the 'iemConfigContactEnable' OID is enabled. The status will show a fault(2) if the contact is f… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.2.3.4.1.3 |
.1.3.6.1.4.1.318.1.1.10.2.3.7
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk iemStatusRelaysTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::iemStatusRelaysTable'
A list of output relays supported by the Environmental Monitor and their status.
The status of the relay.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
iemStatusRelayNumbermandatory
The index of the output relay.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.2.3.7.1.1 |
||||
|
iemStatusRelayNamemandatory
A descriptive name for the output relay set by the
user, denoting its location or purpose. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.2.3.7.1.2 |
||||
|
iemStatusRelayStatusmandatory
The status of the output relay, either faultState(1) or
normalState(2). |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.2.3.7.1.3 |
.1.3.6.1.4.1.318.1.1.10.3.2.1
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk emsOutputRelayControlTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::emsOutputRelayControlTable'
Allows for control of individual output relays. The number of entries is contained in the emsStatusOutputRelayCount OID.
The output relays to control.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
The index to the output relay entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.2.1.1.1 |
||||
|
emsOutputRelayControlOutputRelayNamemandatory
The name of the output relay.
This OID is provided for informational purposes only. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.3.2.1.1.2 |
||||
|
Getting this variable will return the output relay state. If
the output relay is closed, the immediateCloseEMS (1) value will be returned. If the output relay is open, the immediateOpenEMS (2) value will be returned. … |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.2.1.1.3 |
.1.3.6.1.4.1.318.1.1.10.3.3.1
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk emsOutletControlTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::emsOutletControlTable'
Allows for control of individual outlet switches. The number of entries is contained in the emsStatusOutletCount OID.
The outlets to control.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
emsOutletControlOutletIndexmandatory
The index to the outlet entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.3.1.1.1 |
||||
|
emsOutletControlOutletNamemandatory
The name of the outlet.
This OID is provided for informational purposes only. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.3.3.1.1.2 |
||||
|
emsOutletControlOutletCommandmandatory
Getting this variable will return the outlet state. If
the outlet is on, the immediateOnEMS (1) value will be returned. If the outlet is off, the immediateOffEMS (2) value will be returned. Setting this v… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.3.1.1.3 |
.1.3.6.1.4.1.318.1.1.10.3.4.1
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk emsSensorControlTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::emsSensorControlTable'
Allows for control/reset of individual sensors. The number of entries is contained in the emsStatusSensorCount OID.
The sensors to control/reset.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
emsSensorControlSensorIndexmandatory
The index to the sensor entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.4.1.1.1 |
||||
|
emsSensorControlSensorSystemNamemandatory
The system name of the sensor. This describes the hardware system
intent of this sensor. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.3.4.1.1.2 |
||||
|
emsSensorControlSensorUserNamemandatory
The name of the sensor as given by the system user.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.3.4.1.1.3 |
||||
|
emsSensorControlSensorCommandmandatory
Getting this variable will return noCommandEMS(1).
Setting this variable to resetCommandEMS(2) will issue a reset command to the sensor. Some sensors cannot be manually reset and will not be affected by … |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.4.1.1.4 |
.1.3.6.1.4.1.318.1.1.10.3.5.1
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk emsAlarmDeviceControlTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::emsAlarmDeviceControlTable'
Allows for control of individual alarm devices. Note: Some alarm devices are not controllable. The number of entries is contained in the emsStatusAlarmDeviceCount OID.
The alarm devices to control.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
emsAlarmDeviceControlDeviceIndexmandatory
The index to the alarm device entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.5.1.1.1 |
||||||
|
emsAlarmDeviceControlDeviceNamemandatory
The name of the alarm device.
This OID is provided for informational purposes only. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.3.5.1.1.2 |
||||||
|
emsAlarmDeviceControlDeviceCommandmandatory
Getting this variable will return the device state. If
the device is active, the alarmDeviceOnEMS (1) value will be returned. If the device is inactive, the alarmDeviceOffEMS (2) value will be returned. If the device is… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.5.1.1.3 |
.1.3.6.1.4.1.318.1.1.10.3.7.1
·
1 row entry
·
22 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk emsProbeConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::emsProbeConfigTable'
Allows for configuration of individual probes. The number of entries is contained in the emsStatusProbeCount OID.
The probes to configure.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
emsProbeConfigProbeIndexmandatory
The index to the probe entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.7.1.1.1 |
|
emsProbeConfigProbeNamemandatory
The name of the probe.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.3.7.1.1.2 |
|
emsProbeConfigProbeHighTempThreshmandatory
Probe high temperature threshold.
Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.7.1.1.3 |
|
emsProbeConfigProbeLowTempThreshmandatory
Probe low temperature threshold.
Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.7.1.1.4 |
|
Probe high humidity threshold.
Values are represented in whole number percentage. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.7.1.1.5 |
|
emsProbeConfigProbeLowHumidityThreshmandatory
Probe low humidity threshold.
Values are represented in whole number percentage. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.7.1.1.6 |
|
emsProbeConfigProbeMaxTempThreshmandatory
Probe maximum temperature threshold.
Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.7.1.1.7 |
|
emsProbeConfigProbeMinTempThreshmandatory
Probe minimum temperature threshold.
Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.7.1.1.8 |
|
emsProbeConfigProbeDeltaTempmandatory
Probe delta temperature.
Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.7.1.1.9 |
|
emsProbeConfigProbeMaxHumidityThreshmandatory
Probe maximum humidity threshold.
Values are represented in whole number percentage. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.7.1.1.10 |
|
emsProbeConfigProbeMinHumidityThreshmandatory
Probe minimum humidity threshold.
Values are represented in whole number percentage. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.7.1.1.11 |
|
emsProbeConfigProbeDeltaHumiditymandatory
Probe delta humidity.
Values are represented in whole number percentage. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.7.1.1.12 |
|
emsProbeConfigProbeSTIncTempVariancemandatory
Probe short-term increasing temperature variance used for rate of change alarms.
Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Ce… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.7.1.1.13 |
|
emsProbeConfigProbeSTIncTempTimemandatory
Probe short-term increasing temperature time used for rate of change alarms.
Values are represented in whole number minutes. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.7.1.1.14 |
|
emsProbeConfigProbeSTDecTempVariancemandatory
Probe short-term decreasing temperature variance used for rate of change alarms.
Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Ce… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.7.1.1.15 |
|
emsProbeConfigProbeSTDecTempTimemandatory
Probe short-term decreasing temperature time used for rate of change alarms.
Values are represented in whole number minutes. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.7.1.1.16 |
|
emsProbeConfigProbeLTIncTempVariancemandatory
Probe long-term increasing temperature variance used for rate of change alarms.
Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Cel… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.7.1.1.17 |
|
emsProbeConfigProbeLTIncTempTimemandatory
Probe long-term increasing temperature time used for rate of change alarms.
Values are represented in whole number hours. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.7.1.1.18 |
|
emsProbeConfigProbeLTDecTempVariancemandatory
Probe long-term decreasing temperature variance used for rate of change alarms.
Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Cel… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.7.1.1.19 |
|
emsProbeConfigProbeLTDecTempTimemandatory
Probe long-term decreasing temperature time used for rate of change alarms.
Values are represented in whole number hours. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.7.1.1.20 |
|
emsProbeConfigProbeMaxVoltThreshmandatory
Probe maximum voltage threshold in tenths of Volts.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.7.1.1.21 |
|
emsProbeConfigProbeMinVoltThreshmandatory
Probe minimum voltage threshold in tenths of Volts.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.7.1.1.22 |
.1.3.6.1.4.1.318.1.1.10.3.8.1
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk emsInputContactConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::emsInputContactConfigTable'
Allows for configuration of individual input contacts. The number of entries is contained in the emsStatusInputContactCount OID.
The input contacts to configure.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
The index to the input contact entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.8.1.1.1 |
||||
|
The name of the input contact.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.3.8.1.1.2 |
||||
|
Getting this variable will return the normal state of the input contact. If
the normal state is closed, the normallyClosedEMS (1) value will be returned. If the normal state is closed, the normallyOpenEMS (2) value will… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.8.1.1.3 |
.1.3.6.1.4.1.318.1.1.10.3.9.1
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk emsOutputRelayConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::emsOutputRelayConfigTable'
Allows for configuration of individual output relays. The number of entries is contained in the emsStatusOutputRelayCount OID.
The output relays to configure.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
emsOutputRelayConfigOutputRelayIndexmandatory
The index to the output relay entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.9.1.1.1 |
||||
|
emsOutputRelayConfigOutputRelayNamemandatory
The name of the output relay.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.3.9.1.1.2 |
||||
|
Getting this variable will return the normal state of the output relay. If
the normal state is closed, the normallyClosedEMS (1) value will be returned. If the normal state is closed, the normallyOpenEMS (2) value will … |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.9.1.1.3 |
.1.3.6.1.4.1.318.1.1.10.3.10.1
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk emsOutletConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::emsOutletConfigTable'
Allows for configuration of individual outlets. The number of entries is contained in the emsStatusOutletCount OID.
The outlets to configure.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
emsOutletConfigOutletIndexmandatory
The index to the outlet entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.10.1.1.1 |
||||
|
emsOutletConfigOutletNamemandatory
The name of the outlet.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.3.10.1.1.2 |
||||
|
emsOutletConfigOutletNormalStatemandatory
Getting this variable will return the normal state of the outlet. If
the normal state is on, the normallyOnEMS (1) value will be returned. If the normal state is off, the normallyOffEMS (2) value will be returned. … |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.10.1.1.3 |
.1.3.6.1.4.1.318.1.1.10.3.11.1
·
1 row entry
·
5 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk emsSensorConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::emsSensorConfigTable'
Allows for configuration of individual sensors. The number of entries is contained in the emsStatusSensorCount OID.
The sensors to configure.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
emsSensorConfigSensorIndexmandatory
The index to the sensor entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.11.1.1.1 |
||||
|
emsSensorConfigSensorSystemNamemandatory
The system name of the sensor. This describes the hardware system
intent of this sensor. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.3.11.1.1.2 |
||||
|
emsSensorConfigSensorUserNamemandatory
The name of the sensor as given by the system user.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.3.11.1.1.3 |
||||
|
emsSensorConfigSensorNormalStatemandatory
Getting this variable will return the normal state of the sensor. If
the normal state is closed, the normallyClosedEMS (1) value will be returned. If the normal state is closed, the normallyOpenEMS (2) value will be ret… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.11.1.1.4 |
||||
|
emsSensorConfigSensorAlarmDelaymandatory
The delay (in seconds) after a sensor detects an alarm condition before the
condition is reported. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.11.1.1.5 |
.1.3.6.1.4.1.318.1.1.10.3.13.1
·
1 row entry
·
18 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk emsProbeStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::emsProbeStatusTable'
Allows for access of individual probes. The number of entries is contained in the emsStatusProbeCount OID.
The probes to access.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
emsProbeStatusProbeIndexmandatory
The index to the probe entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.13.1.1.1 |
||||||
|
emsProbeStatusProbeNamemandatory
The name of the probe.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.3.13.1.1.2 |
||||||
|
emsProbeStatusProbeTemperaturemandatory
Probe temperature reading.
Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.13.1.1.3 |
||||||
|
emsProbeStatusProbeHighTempThreshmandatory
Probe high temperature threshold.
Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.13.1.1.4 |
||||||
|
emsProbeStatusProbeLowTempThreshmandatory
Probe low temperature threshold.
Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.13.1.1.5 |
||||||
|
emsProbeStatusProbeHumiditymandatory
Probe humidity reading.
Values are represented in whole number percentage. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.13.1.1.6 |
||||||
|
Probe high humidity threshold.
Values are represented in whole number percentage. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.13.1.1.7 |
||||||
|
emsProbeStatusProbeLowHumidityThreshmandatory
Probe low humidity threshold.
Values are represented in whole number percentage. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.13.1.1.8 |
||||||
|
emsProbeStatusProbeSerialNumbermandatory
A label indicating the type (Local[L] or Remote[R]) and Number
of the probe. For example, the first local probe would be L1 and the third remote probe would be R3. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.3.13.1.1.9 |
||||||
|
emsProbeStatusProbeCommStatusmandatory
The state of communications to the probe.
commNeverDiscovered(1) indicates there has never been communications with this device. commsEstablished(2) indicates communication is normal and active with this device. commsLo… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.13.1.1.10 |
||||||
|
emsProbeStatusProbeAlarmStatusmandatory
The alarm status of the probe. This integer should be interpreted
as a bit map, with each bit representing the presence or absence of the specific alarm conditions listed below. The bit will be '1' if the condition is… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.13.1.1.11 |
||||||
|
emsProbeStatusProbeMaxTempThreshmandatory
Probe maximum temperature threshold.
Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.13.1.1.12 |
||||||
|
emsProbeStatusProbeMinTempThreshmandatory
Probe minimum temperature threshold.
Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.13.1.1.13 |
||||||
|
emsProbeStatusProbeMaxHumidityThreshmandatory
Probe maximum humidity threshold.
Values are represented in whole number percentage. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.13.1.1.14 |
||||||
|
emsProbeStatusProbeMinHumidityThreshmandatory
Probe minimum humidity threshold.
Values are represented in whole number percentage. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.13.1.1.15 |
||||||
|
emsProbeStatusProbeVoltagemandatory
Probe voltage reading.
Values are displayed in tenths of Volts DC. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.13.1.1.16 |
||||||
|
emsProbeStatusProbeMaxVoltThreshmandatory
Probe maximum voltage threshold in Volts.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.13.1.1.17 |
||||||
|
emsProbeStatusProbeMinVoltThreshmandatory
Probe minimum voltage threshold in Volts.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.13.1.1.18 |
.1.3.6.1.4.1.318.1.1.10.3.14.1
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk emsInputContactStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::emsInputContactStatusTable'
Allows for access of individual input contacts. The number of entries is contained in the emsStatusInputContactCount OID.
The input contacts to access.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
The index to the input contact entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.14.1.1.1 |
||||
|
The name of the input contact.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.3.14.1.1.2 |
||||
|
Getting this variable will return the state of the input contact. If
the input contact is closed, the contactClosedEMS (1) value will be returned. If the input contact state is open, the contactOpenEMS (2) value will be… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.14.1.1.3 |
||||
|
Getting this variable will return the normal state of the input contact. If
the normal state is closed, the normallyClosedEMS (1) value will be returned. If the normal state is open, the normallyOpenEMS (2) value will b… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.14.1.1.4 |
.1.3.6.1.4.1.318.1.1.10.3.15.1
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk emsOutputRelayStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::emsOutputRelayStatusTable'
Allows for access of individual output relays. The number of entries is contained in the emsStatusOutputRelayCount OID.
The output relays to access.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
emsOutputRelayStatusOutputRelayIndexmandatory
The index to the output relay entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.15.1.1.1 |
||||
|
emsOutputRelayStatusOutputRelayNamemandatory
The name of the output relay.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.3.15.1.1.2 |
||||
|
emsOutputRelayStatusOutputRelayStatemandatory
Getting this variable will return the state of the output relay. If
the output relay is closed, the relayClosedEMS (1) value will be returned. If the output relay is open, the relayOpenEMS (2) value will be returned. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.15.1.1.3 |
||||
|
Getting this variable will return the normal state of the output relay. If
the normal state is closed, the normallyClosedEMS (1) value will be returned. If the normal state is open, the normallyOpenEMS (2) value will be… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.15.1.1.4 |
.1.3.6.1.4.1.318.1.1.10.3.16.1
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk emsOutletStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::emsOutletStatusTable'
Allows for access of individual outlets. The number of entries is contained in the emsStatusOutletCount OID.
The outlets to access.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
emsOutletStatusOutletIndexmandatory
The index to the outlet entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.16.1.1.1 |
||||
|
emsOutletStatusOutletNamemandatory
The name of the outlet.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.3.16.1.1.2 |
||||
|
emsOutletStatusOutletStatemandatory
Getting this variable will return the state of the outlet. If
the outlet is on, the outletOnEMS (1) value will be returned. If the outlet is off, the outletOffEMS (2) value will be returned. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.16.1.1.3 |
||||
|
emsOutletStatusOutletNormalStatemandatory
Getting this variable will return the normal state of the outlet. If
the normal state is on, the normallyOnEMS (1) value will be returned. If the normal state is off, the normallyOffEMS (2) value will be returned. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.16.1.1.4 |
.1.3.6.1.4.1.318.1.1.10.3.17.1
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk emsAlarmDeviceStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::emsAlarmDeviceStatusTable'
Allows for access of individual alarm devices. The number of entries is contained in the emsStatusAlarmDeviceCount OID.
The alarm devices to access.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
emsAlarmDeviceStatusDeviceIndexmandatory
The index to the alarm device entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.17.1.1.1 |
||||||
|
emsAlarmDeviceStatusDeviceNamemandatory
The name of the alarm device.
This OID is provided for informational purposes only. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.3.17.1.1.2 |
||||||
|
emsAlarmDeviceStatusDeviceStatemandatory
Getting this variable will return the device state. If
the device is active, the alarmDeviceOnEMS (1) value will be returned. If the device is inactive, the alarmDeviceOffEMS (2) value will be returned. If the device i… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.17.1.1.3 |
.1.3.6.1.4.1.318.1.1.10.3.18.1
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk emsSensorStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::emsSensorStatusTable'
Allows for access of individual sensors. The number of entries is contained in the emsStatusSensorCount OID.
The sensors to access.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
emsSensorStatusSensorIndexmandatory
The index to the sensor entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.18.1.1.1 |
||||||
|
emsSensorStatusSensorSystemNamemandatory
The system name of the sensor. This describes the hardware system
intent of this sensor. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.3.18.1.1.2 |
||||||
|
emsSensorStatusSensorNamemandatory
The name of the sensor as given by the system user.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.3.18.1.1.3 |
||||||
|
emsSensorStatusSensorStatemandatory
Getting this variable will return the sensor state. If the sensor is faulted,
the sensorFaultedEMS (1) value will be returned. If the sensor is not faulted, the sensorOKEMS (2) value will be returned. If the sensor is n… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.18.1.1.4 |
||||||
|
emsSensorStatusSensorNormalStatemandatory
Getting this variable will return the normal state of the sensor. If
the normal state is closed, the normallyClosedEMS (1) value will be returned. If the normal state is closed, the normallyOpenEMS (2) value will be ret… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.18.1.1.5 |
||||||
|
emsSensorStatusSensorAlarmDelaymandatory
The delay (in seconds) after a sensor detects an alarm condition before the
condition is reported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.18.1.1.6 |
.1.3.6.1.4.1.318.1.1.10.3.19.1
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk emsSmokeSensorConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::emsSmokeSensorConfigTable'
Allows for the configuration of individual sensors.
The sensors to configure.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
emsSmokeSensorConfigSensorIndexmandatory
The index to the sensor entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.19.1.1.1 |
||||||
|
emsSmokeSensorConfigSensorNamemandatory
The user defined name of the smoke sensor.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.3.19.1.1.2 |
||||||
|
emsSmokeSensorConfigSensorLocationmandatory
The user defined location of the smoke sensor.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.3.19.1.1.3 |
||||||
|
emsSmokeSensorConfigSensorSeveritymandatory
The severity of the alarm that will be triggered when
the smoke sensor is activated. The alarms can be critical(1), warning(2) or informational(3). |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.19.1.1.4 |
.1.3.6.1.4.1.318.1.1.10.3.19.2
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk emsVibrationSensorConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::emsVibrationSensorConfigTable'
Allows for the configuration of individual sensors.
The sensors to configure.
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
emsVibrationSensorConfigSensorIndexmandatory
The index to the sensor entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.19.2.1.1 |
||||||
|
emsVibrationSensorConfigSensorNamemandatory
The user defined name of the vibration sensor.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.3.19.2.1.2 |
||||||
|
The user defined location of the vibration sensor.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.3.19.2.1.3 |
||||||
|
The severity of the alarm that will be triggered when
the vibration sensor is activated. The alarms can be critical(1), warning(2) or informational(3). |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.19.2.1.4 |
.1.3.6.1.4.1.318.1.1.10.3.19.3
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk emsFluidSensorConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::emsFluidSensorConfigTable'
Allows for the configuration of individual sensors.
The sensors to configure.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
emsFluidSensorConfigSensorIndexmandatory
The index to the sensor entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.19.3.1.1 |
||||||
|
emsFluidSensorConfigSensorNamemandatory
The user defined name of the fluid sensor.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.3.19.3.1.2 |
||||||
|
emsFluidSensorConfigSensorLocationmandatory
The user defined location of the fluid sensor.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.3.19.3.1.3 |
||||||
|
emsFluidSensorConfigSensorSeveritymandatory
The severity of the alarm that will be triggered when
the fluid sensor is activated. The alarms can be critical(1), warning(2) or informational(3). |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.19.3.1.4 |
.1.3.6.1.4.1.318.1.1.10.3.19.4
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk emsDoorSensorConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::emsDoorSensorConfigTable'
Allows for the configuration of individual sensors.
The sensors to configure.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
emsDoorSensorConfigSensorIndexmandatory
The index to the sensor entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.19.4.1.1 |
||||||
|
emsDoorSensorConfigSensorNamemandatory
The user defined name of the door sensor.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.3.19.4.1.2 |
||||||
|
emsDoorSensorConfigSensorLocationmandatory
The user defined location of the door sensor.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.3.19.4.1.3 |
||||||
|
emsDoorSensorConfigSensorSeveritymandatory
The severity of the alarm that will be triggered when
the door sensor is activated. The alarms can be critical(1), warning(2) or informational(3). |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.19.4.1.4 |
.1.3.6.1.4.1.318.1.1.10.3.19.5
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk emsLeakRopeConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::emsLeakRopeConfigTable'
Allows for the configuration of an individual leak rope.
The leak rope to configure.
Indexes
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
emsLeakRopeConfigIndexmandatory
The index of the leak rope entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.19.5.1.1 |
||||||||||
|
emsLeakRopeConfigNamemandatory
The user-defined name of the leak rope.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.3.19.5.1.2 |
||||||||||
|
emsLeakRopeConfigLocationmandatory
The user-defined location of the leak rope.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.3.19.5.1.3 |
||||||||||
|
emsLeakRopeConfigSeveritymandatory
The severity of the alarm that will be triggered when the leak rope is activated.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.19.5.1.4 |
.1.3.6.1.4.1.318.1.1.10.3.20.2
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk emsSmokeSensorStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::emsSmokeSensorStatusTable'
Allows for the access of individual sensors.
The sensor to access.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
emsSmokeSensorStatusSensorIndexmandatory
The index to the sensor entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.20.2.1.1 |
||||||
|
emsSmokeSensorStatusSensorNamemandatory
The user defined name of the smoke sensor.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.3.20.2.1.2 |
||||||
|
emsSmokeSensorStatusSensorLocationmandatory
The user defined location of the smoke sensor.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.3.20.2.1.3 |
||||||
|
emsSmokeSensorStatusSensorStatemandatory
The state of the smoke sensor.
smokeDetected (1) indicates there is smoke. noSmoke (2) indicates there is no smoke. unknown (3) indicates the state is unknown. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.20.2.1.4 |
||||||
|
emsSmokeSensorStatusSensorSeveritymandatory
The severity of the alarm that will be triggered when
the smoke sensor is activated. The alarms can be critical(1), warning(2) or informational(3). |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.20.2.1.5 |
||||||
|
emsSmokeSensorCommStatusmandatory
The communication status of the smoke sensor.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.20.2.1.6 |
.1.3.6.1.4.1.318.1.1.10.3.20.4
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk emsVibrationSensorStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::emsVibrationSensorStatusTable'
Allows for the access of individual sensors.
The sensor to access.
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
emsVibrationSensorStatusSensorIndexmandatory
The index to the sensor entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.20.4.1.1 |
||||||
|
emsVibrationSensorStatusSensorNamemandatory
The user defined name of the vibration sensor.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.3.20.4.1.2 |
||||||
|
The user defined location of the vibration sensor.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.3.20.4.1.3 |
||||||
|
emsVibrationSensorStatusSensorStatemandatory
The state of the vibration sensor.
vibrationDetected (1) indicates there is vibration. noVibration (2) indicates there is no vibration. unknown (3) indicates the state is unknown. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.20.4.1.4 |
||||||
|
The severity of the alarm that will be triggered when
the vibration sensor is activated. The alarms can be critical(1), warning(2) or informational(3). |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.20.4.1.5 |
||||||
|
emsVibrationSensorCommStatusmandatory
The communication status of the vibration sensor.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.20.4.1.6 |
.1.3.6.1.4.1.318.1.1.10.3.20.6
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk emsFluidSensorStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::emsFluidSensorStatusTable'
Allows for the access of individual sensors.
The sensors to access.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
emsFluidSensorStatusSensorIndexmandatory
The index to the sensor entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.20.6.1.1 |
||||||
|
emsFluidSensorStatusSensorNamemandatory
The user defined name of the fluid sensor.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.3.20.6.1.2 |
||||||
|
emsFluidSensorStatusSensorLocationmandatory
The user defined location of the fluid sensor.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.3.20.6.1.3 |
||||||
|
emsFluidSensorStatusSensorStatemandatory
The state of the fluid sensor.
fluidDetected (1) indicates there is fluid leak. noFluid (2) indicates there is no fluid leak. unknown (3) indicates the state is unknown. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.20.6.1.4 |
||||||
|
emsFluidSensorStatusSensorSeveritymandatory
The severity of the alarm that will be triggered when
the fluid sensor is activated. The alarms can be critical(1), warning(2) or informational(3). |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.20.6.1.5 |
||||||
|
emsFluidSensorCommStatusmandatory
The communication status of the fluid sensor.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.20.6.1.6 |
.1.3.6.1.4.1.318.1.1.10.3.20.8
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk emsDoorSensorStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::emsDoorSensorStatusTable'
Allows for the access of individual sensors.
The sensor to access.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
emsDoorSensorStatusSensorIndexmandatory
The index to the sensor entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.20.8.1.1 |
||||||
|
emsDoorSensorStatusSensorNamemandatory
The user defined name of the door sensor.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.3.20.8.1.2 |
||||||
|
emsDoorSensorStatusSensorLocationmandatory
The user defined location of the door sensor.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.3.20.8.1.3 |
||||||
|
emsDoorSensorStatusSensorStatemandatory
The state of the door sensor.
open (1) indicates door open. closed (2) indicates door closed. unknown (3) indicates the state is unknown. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.20.8.1.4 |
||||||
|
emsDoorSensorStatusSensorSeveritymandatory
The severity of the alarm that will be triggered when
the door sensor is activated. The alarms can be critical(1), warning(2) or informational(3). |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.20.8.1.5 |
||||||
|
emsDoorSensorCommStatusmandatory
The communication status of the door sensor.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.20.8.1.6 |
.1.3.6.1.4.1.318.1.1.10.3.20.10
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk emsLeakRopeStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::emsLeakRopeStatusTable'
Allows for the access of individual leak ropes.
The leak rope to access.
Indexes
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
emsLeakRopeStatusIndexmandatory
The index of the leak rope entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.3.20.10.1.1 |
||||||||||
|
emsLeakRopeStatusNamemandatory
The user defined name of the leak rope.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.3.20.10.1.2 |
||||||||||
|
emsLeakRopeStatusLocationmandatory
The user defined location of the leak rope.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.3.20.10.1.3 |
||||||||||
|
emsLeakRopeStatusStatemandatory
The state of the leak rope.
The values can be noleak(1), leakdetected(2), or unknown(3). |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.20.10.1.4 |
||||||||||
|
emsLeakRopeStatusSeveritymandatory
The severity of the alarm that will be triggered when the leak rope is activated.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.20.10.1.5 |
||||||||||
|
emsLeakRopeCommStatusmandatory
The communication status of the leak rope.
The values can be connected(1), disconnected(2), or commsLost(3). |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.3.20.10.1.6 |
.1.3.6.1.4.1.318.1.1.10.4.1.2
·
1 row entry
·
7 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk memModulesStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::memModulesStatusTable'
Allows for getting status information from the modules attached to the system.
The unit to get data from.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
memModulesStatusModuleNumbermandatory
The module number.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.1.2.1.1 |
|
memModulesStatusModuleNamemandatory
The module name.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.1.2.1.2 |
|
memModulesStatusModuleLocationmandatory
The location of the module.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.1.2.1.3 |
|
memModulesStatusModelNumbermandatory
The model number of the module.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.1.2.1.4 |
|
memModulesStatusSerialNumbermandatory
The serial number of the module.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.1.2.1.5 |
|
memModulesStatusFirmwareRevmandatory
The firmware revision of the module.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.1.2.1.6 |
|
memModulesStatusHardwareRevmandatory
The hardware revision.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.1.2.1.7 |
.1.3.6.1.4.1.318.1.1.10.4.1.4
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk memModulesConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::memModulesConfigTable'
Allows for getting status information from the modules attached to the system.
The unit to get data from.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
memModulesConfigModuleNumbermandatory
The module number.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.1.4.1.1 |
|
memModulesConfigModuleNamemandatory
The module name.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.1.4.1.2 |
|
memModulesConfigModuleLocationmandatory
The location of the module.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.1.4.1.3 |
.1.3.6.1.4.1.318.1.1.10.4.2.3
·
1 row entry
·
10 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk memSensorsStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::memSensorsStatusTable'
Allows for getting sensor status information.
The unit to get data from.
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
memSensorsStatusModuleNumbermandatory
The number of the module that the sensor is attached to.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.2.3.1.1 |
||||||
|
memSensorsStatusSensorNumbermandatory
The number of this sensor on the module.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.2.3.1.2 |
||||||
|
memSensorsStatusSensorNamemandatory
The sensor name.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.2.3.1.3 |
||||||
|
memSensorsStatusSensorLocationmandatory
The location of the sensor.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.2.3.1.4 |
||||||
|
memSensorsTemperaturemandatory
The sensor's current temperature reading.
Units are displayed in the scale shown in the memSensorsStatusSysTempUnits OID (Celsius or Fahrenheit). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.2.3.1.5 |
||||||
|
memSensorsHumiditymandatory
The current humidity reading from the sensor.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.2.3.1.6 |
||||||
|
memSensorsCommStatusmandatory
The communications status of the sensor.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.2.3.1.7 |
||||||
|
memSensorsAlarmStatusmandatory
The alarm status of the sensor.
memWarning is not applicable to voltage sensor. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.2.3.1.8 |
||||||
|
memSensorsTemperatureHighPrecmandatory
The current temperature is displayed in tenths of degrees in the scale
shown in the memSensorsStatusSysTempUnits OID (Celsius or Fahrenheit). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.2.3.1.9 |
||||||
|
memSensorsVoltagemandatory
The sensor's current voltage reading.
Values are displayed in tenths of Volts DC. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.2.3.1.10 |
.1.3.6.1.4.1.318.1.1.10.4.2.5
·
1 row entry
·
25 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk memSensorsConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::memSensorsConfigTable'
Allows for getting configuration information from sensors attached to the system.
The unit to get data from.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
memSensorsConfigModuleNumbermandatory
The number of the module that the sensor is attached to.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.2.5.1.1 |
||||
|
memSensorsConfigSensorNumbermandatory
The number of this sensor on the module.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.2.5.1.2 |
||||
|
memSensorsNamemandatory
A descriptive name for the sensor.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.2.5.1.3 |
||||
|
memSensorsLocationmandatory
The location of the sensor.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.2.5.1.4 |
||||
|
memSensorsAlarmGenerationmandatory
Enable or disable alarm generation on this sensor.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.2.5.1.5 |
||||
|
memSensorsTempMaxThreshmandatory
The temperature at which the MEM will generate a maximum
temperature threshold violation alarm on this sensor. The temperature scale is based on the memSensorsStatusSysTempUnits OID. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.2.5.1.6 |
||||
|
memSensorsTempHighThreshmandatory
The temperature at which the MEM will generate a high
temperature threshold violation alarm on this sensor. The temperature scale is based on the memSensorsStatusSysTempUnits OID. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.2.5.1.7 |
||||
|
memSensorsTempLowThreshmandatory
The temperature at which the MEM will generate a low
temperature threshold violation alarm on this sensor. The temperature scale is based on the memSensorsStatusSysTempUnits OID. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.2.5.1.8 |
||||
|
memSensorsTempMinThreshmandatory
The temperature at which the MEM will generate a minimum
temperature threshold violation alarm on this sensor. The temperature scale is based on the memSensorsStatusSysTempUnits OID. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.2.5.1.9 |
||||
|
memSensorsTempThreshHysteresismandatory
The change in temperature required to cause a
temperature alarm to change from an active to an inactive state. The temperature scale is based on the memSensorsStatusSysTempUnits OID. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.2.5.1.10 |
||||
|
The value of the temperature short-term decreasing rate
time that will cause an alarm to be generated. The temperature scale is based on the memSensorsStatusSysTempUnits OID. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.2.5.1.11 |
||||
|
memSensorsTempShortDecRateThreshTimemandatory
The time over which the temperature may not decrease
beyond the value specified by the temperature short-term decreasing rate threshold value. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.2.5.1.12 |
||||
|
The value of the temperature short-term increasing rate
time that will cause an alarm to be generated. The temperature scale is based on the memSensorsStatusSysTempUnits OID. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.2.5.1.13 |
||||
|
memSensorsTempShortIncRateThreshTimemandatory
The time over which the temperature may not increase
beyond the value specified by the temperature short-term increasing rate threshold value. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.2.5.1.14 |
||||
|
memSensorsTempLongDecRateThreshValuemandatory
The value of the temperature long-term decreasing rate
time that will cause an alarm to be generated. The temperature scale is based on the memSensorsStatusSysTempUnits OID. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.2.5.1.15 |
||||
|
memSensorsTempLongDecRateThreshTimemandatory
The time over which the temperature may not decrease
beyond the value specified by the temperature long-term decreasing rate threshold value. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.2.5.1.16 |
||||
|
memSensorsTempLongIncRateThreshValuemandatory
The value of the temperature long-term increasing rate
time that will cause an alarm to be generated. The temperature scale is based on the memSensorsStatusSysTempUnits OID. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.2.5.1.17 |
||||
|
memSensorsTempLongIncRateThreshTimemandatory
The time over which the temperature may not increase
beyond the value specified by the temperature long-term increasing rate threshold value. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.2.5.1.18 |
||||
|
memSensorsHumidityMaxThreshmandatory
The humidity at which the maximum humidity threshold alarm
will be generated. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.2.5.1.19 |
||||
|
memSensorsHumidityHighThreshmandatory
The humidity at which the high humidity threshold alarm
will be generated. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.2.5.1.20 |
||||
|
memSensorsHumidityLowThreshmandatory
The humidity at which the low humidity threshold alarm
will be generated. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.2.5.1.21 |
||||
|
memSensorsHumidityMinThreshmandatory
The humidity at which the minimum humidity threshold alarm
will be generated. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.2.5.1.22 |
||||
|
memSensorsHumidityThreshHysteresismandatory
The change in humidity required to cause an active humidity
alarm to change to the inactive state. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.2.5.1.23 |
||||
|
memSensorsVoltMaxThreshmandatory
The voltage in tenths of volts at which the MEM will generate a maximum
voltage threshold violation alarm on this sensor. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.2.5.1.24 |
||||
|
memSensorsVoltMinThreshmandatory
The voltage in tenths of volts at which the MEM will generate a minimum
voltage threshold violation alarm on this sensor. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.2.5.1.25 |
.1.3.6.1.4.1.318.1.1.10.4.3.2
·
1 row entry
·
8 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk memInputsStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::memInputsStatusTable'
Allows for getting input status information.
The unit to get data from.
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
memInputsStatusModuleNumbermandatory
The number of the module that the input is attached to.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.3.2.1.1 |
||||||||
|
memInputsStatusInputNumbermandatory
The number of this input on the module.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.3.2.1.2 |
||||||||
|
memInputsStatusInputNamemandatory
The input name.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.3.2.1.3 |
||||||||
|
memInputsStatusInputLocationmandatory
The location of the input.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.3.2.1.4 |
||||||||
|
memInputsStatusCurrentStatemandatory
The current state of the input. This OID will return
inputStateNotAplicable(4) for analog input types. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.3.2.1.5 |
||||||||
|
memInputsStatusCurrentAnalogValuemandatory
The current analog value of the input in the units defined
by the user. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.3.2.1.6 |
||||||||
|
memInputsStatusAlarmStatusmandatory
The alarm status of the input.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.3.2.1.7 |
||||||||
|
memInputsCommStatusmandatory
The communications status of the input. This OID is only supported by NBRK0200.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.3.2.1.8 |
.1.3.6.1.4.1.318.1.1.10.4.3.4
·
1 row entry
·
25 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk memInputsConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::memInputsConfigTable'
Allows for getting input configuration information.
The unit to get data from.
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
memInputsConfigModuleNumbermandatory
The number of the module that the input is attached to.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.3.4.1.1 |
||||||||||
|
memInputsConfigInputNumbermandatory
The number of this input on the module.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.3.4.1.2 |
||||||||||
|
memInputNamemandatory
The name of the input.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.3 |
||||||||||
|
memInputLocationmandatory
The location of the input.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.4 |
||||||||||
|
memInputTypemandatory
The type of input this contact will take.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.3.4.1.5 |
||||||||||
|
memInputAlarmGenerationmandatory
Enable or disable alarm generation on this input.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.3.4.1.6 |
||||||||||
|
memInputNormalStatemandatory
Defines the normal (no alarm) state of the input.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.3.4.1.7 |
||||||||||
|
memInputAbnormalSeveritymandatory
Defines the severity of the event that is associated
with the abnormal state of the input. This OID will return inputSeverityNotApplicable(4) for analog input types. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.3.4.1.8 |
||||||||||
|
memInputNumberCalibrationPointsmandatory
The number of calibration points that are required for
this input. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.3.4.1.9 |
||||||||||
|
memInputAnalogCalibrationPoint1mandatory
The electrical value that the input sensor will measure at the
first calibration point. This OID is relevant only for inputs configured as analog type (ma or V). |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.10 |
||||||||||
|
memInputAnalogCalibrationPoint2mandatory
The electrical value that the input sensor will measure at the
second calibration point. This OID is relevant only for inputs configured as analog type (ma or V). |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.11 |
||||||||||
|
memInputAnalogCalibrationPoint3mandatory
The electrical value that the input sensor will measure at the
third calibration point. This OID is relevant only for inputs configured as analog type (ma or V). |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.12 |
||||||||||
|
memInputAnalogCalibrationPoint4mandatory
The electrical value that the input sensor will measure at the
fourth calibration point. This OID is relevant only for inputs configured as analog type (ma or V). |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.13 |
||||||||||
|
memInputAnalogCalibrationPoint5mandatory
The electrical value that the input sensor will measure at the
fifth calibration point. This OID is relevant only for inputs configured as analog type (ma or V). |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.14 |
||||||||||
|
memInputAnalogCalibrationPoint1Valuemandatory
The value of the input, in units of measure defined by
the user, that corresponds to the current setting at the first calibration point. |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.15 |
||||||||||
|
memInputAnalogCalibrationPoint2Valuemandatory
The value of the input, in units of measure defined by
the user, that corresponds to the current setting at the second calibration point. |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.16 |
||||||||||
|
memInputAnalogCalibrationPoint3Valuemandatory
The value of the input, in units of measure defined by
the user, that corresponds to the current setting at the third calibration point. |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.17 |
||||||||||
|
memInputAnalogCalibrationPoint4Valuemandatory
The value of the input, in units of measure defined by
the user, that corresponds to the current setting at the fourth calibration point. |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.18 |
||||||||||
|
memInputAnalogCalibrationPoint5Valuemandatory
The value of the input, in units of measure defined by
the user, that corresponds to the current setting at the fifth calibration point. |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.19 |
||||||||||
|
memInputAnalogMeasurementUnitsmandatory
The units of measure to be used for this input.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.20 |
||||||||||
|
memInputAnalogMaxThreshmandatory
The input value at which a maximum threshold violation
alarm will be generated on this input. |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.21 |
||||||||||
|
memInputAnalogHighThreshmandatory
The input value at which a high threshold violation
alarm will be generated on this input. |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.22 |
||||||||||
|
memInputAnalogLowThreshmandatory
The input value at which a low threshold violation
alarm will be generated on this input. |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.23 |
||||||||||
|
memInputAnalogMinThreshmandatory
The input value at which a minimum threshold violation
alarm will be generated on this input. |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.24 |
||||||||||
|
memInputAnalogThreshHysteresismandatory
The change in value required to cause an alarm on this input
to change from active to inactive. |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.3.4.1.25 |
.1.3.6.1.4.1.318.1.1.10.4.4.2
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk memOutputStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::memOutputStatusTable'
Allows for getting output status information.
The unit to get data from.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
memOutputStatusModuleNumbermandatory
The number of the module that the output is attached to.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.4.2.1.1 |
||||
|
memOutputStatusOutputNumbermandatory
The number of this output on the module.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.4.2.1.2 |
||||
|
memOutputStatusOutputNamemandatory
The output name.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.4.2.1.3 |
||||
|
memOutputStatusOutputLocationmandatory
The location of the output.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.4.2.1.4 |
||||
|
memOutputStatusCurrentStatemandatory
The state of the output.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.4.2.1.5 |
||||
|
memOutputStatusAlarmStatemandatory
The alarm state of the output.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.4.2.1.6 |
.1.3.6.1.4.1.318.1.1.10.4.4.4
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk memOutputConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::memOutputConfigTable'
Allows for getting output configuration information.
The unit to get data from.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
memOutputConfigModuleNumbermandatory
The number of the module that the output is attached to.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.4.4.1.1 |
||||
|
memOutputConfigOutputNumbermandatory
The number of this output on the module.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.4.4.1.2 |
||||
|
memOutputNamemandatory
The name of the output.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.4.4.1.3 |
||||
|
memOutputLocationmandatory
The location of the output.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.4.4.1.4 |
||||
|
memOutputNormalStatemandatory
The state of the output that will not generate an alarm.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.4.4.1.5 |
||||
|
memOutputActionmandatory
Manual control actions for the output. SNMP get command will return the state
of the output, SNMP set of this OID controls the output. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.4.4.1.6 |
.1.3.6.1.4.1.318.1.1.10.4.5.2
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk memOutletStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::memOutletStatusTable'
Allows for getting outlet status information.
The unit to get data from.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
memOutletStatusModuleNumbermandatory
The number of the module that the outlet is attached to.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.5.2.1.1 |
||||
|
memOutletStatusOutletNumbermandatory
The number of this outlet on the module.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.5.2.1.2 |
||||
|
memOutletStatusOutletNamemandatory
The outlet name.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.5.2.1.3 |
||||
|
memOutletStatusOutletLocationmandatory
The location of the outlet.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.5.2.1.4 |
||||
|
memOutletStatusCurrentStatemandatory
The state of the outlet.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.5.2.1.5 |
||||
|
memOutletStatusAlarmStatemandatory
The alarm state of the outlet.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.5.2.1.6 |
.1.3.6.1.4.1.318.1.1.10.4.5.4
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk memOutletConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::memOutletConfigTable'
Allows for getting outlet configuration information.
The unit to get data from.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
memOutletConfigModuleNumbermandatory
The number of the module that the Outlet is attached to.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.5.4.1.1 |
||||
|
memOutletConfigOutletNumbermandatory
The number of this Outlet on the module.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.5.4.1.2 |
||||
|
memOutletNamemandatory
The name of the Outlet.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.5.4.1.3 |
||||
|
memOutletLocationmandatory
The location of the Outlet.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.5.4.1.4 |
||||
|
memOutletNormalStatemandatory
The state of the Outlet that will not generate an alarm.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.5.4.1.5 |
||||
|
memOutletActionmandatory
Manual control actions for the Outlet. Get displays state
of outlet, set controls outlet. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.5.4.1.6 |
.1.3.6.1.4.1.318.1.1.10.4.6.2
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk memBeaconStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::memBeaconStatusTable'
Allows for getting beacon status information.
The unit to get data from.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
memBeaconStatusModuleNumbermandatory
The number of the module that the beacon is attached to.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.6.2.1.1 |
||||
|
memBeaconStatusBeaconNumbermandatory
The number of this beacon on the module.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.6.2.1.2 |
||||
|
memBeaconStatusBeaconNamemandatory
The beacon name.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.6.2.1.3 |
||||
|
memBeaconStatusBeaconLocationmandatory
The location of the beacon.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.6.2.1.4 |
||||
|
memBeaconStatusCurrentStatemandatory
The state of the beacon.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.6.2.1.5 |
||||
|
memBeaconStatusAlarmStatemandatory
The alarm state of the beacon.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.6.2.1.6 |
.1.3.6.1.4.1.318.1.1.10.4.6.4
·
1 row entry
·
5 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk memBeaconConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::memBeaconConfigTable'
Allows for getting beacon configuration information.
The unit to get data from.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
memBeaconConfigModuleNumbermandatory
The number of the module that the beacon is attached to.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.6.4.1.1 |
||||
|
memBeaconConfigBeaconNumbermandatory
The number of this beacon on the module.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.6.4.1.2 |
||||
|
memBeaconConfigNamemandatory
The name of the beacon.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.6.4.1.3 |
||||
|
memBeaconConfigLocationmandatory
The location of the beacon.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.6.4.1.4 |
||||
|
memBeaconActionmandatory
Control action (on/off) for the beacon. Setting this OID will turn the
beacon on/off. Getting this OID will respond with the current state. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.6.4.1.5 |
.1.3.6.1.4.1.318.1.1.10.4.7.2
·
1 row entry
·
8 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk memSmokeSensorStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::memSmokeSensorStatusTable'
Allows for the access of individual sensors.
The sensor to access.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
memSmokeSensorStatusModuleIndexmandatory
The index to the module entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.7.2.1.1 |
||||||
|
memSmokeSensorStatusSensorIndexmandatory
The index to the sensor entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.7.2.1.2 |
||||||
|
memSmokeSensorStatusSensorNamemandatory
The user defined name of the smoke sensor.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.7.2.1.3 |
||||||
|
memSmokeSensorStatusSensorLocationmandatory
The user defined location of the smoke sensor.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.7.2.1.4 |
||||||
|
memSmokeSensorStatusSensorStatemandatory
The state of the smoke sensor.
smokeDetected (1) indicates there is smoke. noSmoke (2) indicates there is no smoke. unknown (3) indicates the state is unknown. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.7.2.1.5 |
||||||
|
memSmokeSensorStatusSensorSeveritymandatory
The severity of the alarm that will be triggered when
the smoke sensor is activated. The alarms can be critical(1), warning(2) or informational(3). |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.7.2.1.6 |
||||||
|
memSmokeStatusAlarmStatusmandatory
The alarm status of the smoke sensor.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.7.2.1.7 |
||||||
|
memSmokeSensorCommStatusmandatory
The communication status of the smoke sensor.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.7.2.1.8 |
.1.3.6.1.4.1.318.1.1.10.4.7.4
·
1 row entry
·
8 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk memVibrationSensorStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::memVibrationSensorStatusTable'
Allows for the access of individual sensors.
The sensors to access.
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
memVibrationSensorStatusModuleIndexmandatory
The index to the sensor module entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.7.4.1.1 |
||||||
|
memVibrationSensorStatusSensorIndexmandatory
The index to the sensor entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.7.4.1.2 |
||||||
|
memVibrationSensorStatusSensorNamemandatory
The user defined name of the vibration sensor.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.7.4.1.3 |
||||||
|
The user defined location of the vibration sensor.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.7.4.1.4 |
||||||
|
memVibrationSensorStatusSensorStatemandatory
The state of the vibration sensor.
vibrationDetected (1) indicates there is vibration. noVibration (2) indicates there is no vibration. unknown (3) indicates the state is unknown. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.7.4.1.5 |
||||||
|
The severity of the alarm that will be triggered when
the vibration sensor is activated. The alarms can be critical(1), warning(2) or informational(3). |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.7.4.1.6 |
||||||
|
memVibrationStatusAlarmStatusmandatory
The alarm status of the vibration sensor.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.7.4.1.7 |
||||||
|
memVibrationSensorCommStatusmandatory
The communication status of the vibration sensor.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.7.4.1.8 |
.1.3.6.1.4.1.318.1.1.10.4.7.6
·
1 row entry
·
8 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk memFluidSensorStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::memFluidSensorStatusTable'
Allows for access of individual sensors.
The sensor to access.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
memFluidSensorStatusModuleIndexmandatory
The index to the sensor module entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.7.6.1.1 |
||||||
|
memFluidSensorStatusSensorIndexmandatory
The index to the sensor entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.7.6.1.2 |
||||||
|
memFluidSensorStatusSensorNamemandatory
The user defined name of the fluid sensor.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.7.6.1.3 |
||||||
|
memFluidSensorStatusSensorLocationmandatory
The user defined location of the fluid sensor.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.7.6.1.4 |
||||||
|
memFluidSensorStatusSensorStatemandatory
The state of the fluid sensor.
fluidDetected (1) indicates there is fluid leak. noFluid (2) indicates there is no fluid leak. unknown (3) indicates the state is unknown. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.7.6.1.5 |
||||||
|
memFluidSensorStatusSensorSeveritymandatory
The severity of the alarm that will be triggered when
the fluid sensor is activated. The alarms can be critical(1), warning(2) or informational(3). |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.7.6.1.6 |
||||||
|
memFluidStatusAlarmStatusmandatory
The alarm status of the fluid sensor.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.7.6.1.7 |
||||||
|
memFluidSensorCommStatusmandatory
The communication status of the fluid sensor.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.7.6.1.8 |
.1.3.6.1.4.1.318.1.1.10.4.7.8
·
1 row entry
·
8 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk memDoorSensorStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::memDoorSensorStatusTable'
Allows for the access of individual sensors.
The sensor to access.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
memDoorSensorStatusModuleIndexmandatory
The index to the sensor module entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.7.8.1.1 |
||||||
|
memDoorSensorStatusSensorIndexmandatory
The index to the sensor entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.7.8.1.2 |
||||||
|
memDoorSensorStatusSensorNamemandatory
The user defined name of the door sensor.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.7.8.1.3 |
||||||
|
memDoorSensorStatusSensorLocationmandatory
The user defined location of the door sensor.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.7.8.1.4 |
||||||
|
memDoorSensorStatusSensorStatemandatory
The state of the door sensor.
open (1) indicates door open. closed (2) indicates door closed. unknown (3) indicates the state is unknown. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.7.8.1.5 |
||||||
|
memDoorSensorStatusSensorSeveritymandatory
The severity of the alarm that will be triggered when
the door sensor is activated. The alarms can be critical(1), warning(2) or informational(3). |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.7.8.1.6 |
||||||
|
memDoorStatusAlarmStatusmandatory
The alarm status of the door sensor.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.7.8.1.7 |
||||||
|
memDoorSensorCommStatusmandatory
The communication status of the door sensor.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.7.8.1.8 |
.1.3.6.1.4.1.318.1.1.10.4.7.9
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk memSmokeSensorConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::memSmokeSensorConfigTable'
Allows for the configuration of individual sensors.
The sensors to configure.
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
The index to the sensor module entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.7.9.1.1 |
||||||
|
memSmokeSensorConfigSensorIndexmandatory
The index to the sensor entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.7.9.1.2 |
||||||
|
memSmokeSensorConfigSensorNamemandatory
The user defined name of the smoke sensor.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.7.9.1.3 |
||||||
|
memSmokeSensorConfigSensorLocationmandatory
The user defined location of the smoke sensor.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.7.9.1.4 |
||||||
|
memSmokeSensorConfigSensorSeveritymandatory
The severity of the alarm that will be triggered when
the smoke sensor is activated. The alarms can be critical(1), warning(2) or informational(3). |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.7.9.1.5 |
||||||
|
memSmokeSensorConfigAlarmGenerationmandatory
Enable or disable alarm generation on this input.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.7.9.1.6 |
.1.3.6.1.4.1.318.1.1.10.4.7.10
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk memVibrationSensorConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::memVibrationSensorConfigTable'
Allows for the configuration of individual sensors.
The sensor to configure.
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
memVibrationSensorModuleConfigIndexmandatory
The index to the sensor module entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.7.10.1.1 |
||||||
|
memVibrationSensorConfigSensorIndexmandatory
The index to the sensor entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.7.10.1.2 |
||||||
|
memVibrationSensorConfigSensorNamemandatory
The user defined name of the vibration sensor.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.7.10.1.3 |
||||||
|
The user defined location of the vibration sensor.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.7.10.1.4 |
||||||
|
The severity of the alarm that will be triggered when
the vibration sensor is activated. The alarms can be critical(1), warning(2) or informational(3). |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.7.10.1.5 |
||||||
|
Enable or disable alarm generation on this input.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.7.10.1.6 |
.1.3.6.1.4.1.318.1.1.10.4.7.11
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk memFluidSensorConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::memFluidSensorConfigTable'
Allows for the configuration of individual sensors.
The sensor to configure.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
memFluidSensorModuleConfigIndexmandatory
The index to the sensor module entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.7.11.1.1 |
||||||
|
memFluidSensorConfigSensorIndexmandatory
The index to the sensor entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.7.11.1.2 |
||||||
|
memFluidSensorConfigSensorNamemandatory
The user defined name of the fluid sensor.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.7.11.1.3 |
||||||
|
memFluidSensorConfigSensorLocationmandatory
The user defined location of the fluid sensor.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.7.11.1.4 |
||||||
|
memFluidSensorConfigSensorSeveritymandatory
The severity of the alarm that will be triggered when
the fluid sensor is activated. The alarms can be critical(1), warning(2) or informational(3). |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.7.11.1.5 |
||||||
|
memFluidSensorConfigAlarmGenerationmandatory
Enable or disable alarm generation on this input.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.7.11.1.6 |
.1.3.6.1.4.1.318.1.1.10.4.7.12
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk memDoorSensorConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::memDoorSensorConfigTable'
Allows for the configuration of individual sensors.
The sensors to configure.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
memDoorSensorModuleConfigIndexmandatory
The index to the sensor module entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.7.12.1.1 |
||||||
|
memDoorSensorConfigSensorIndexmandatory
The index to the sensor entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.7.12.1.2 |
||||||
|
memDoorSensorConfigSensorNamemandatory
The user defined name of the door sensor.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.7.12.1.3 |
||||||
|
memDoorSensorConfigSensorLocationmandatory
The user defined location of the door sensor.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.7.12.1.4 |
||||||
|
memDoorSensorConfigSensorSeveritymandatory
The severity of the alarm that will be triggered when
the door sensor is activated. The alarms can be critical(1), warning(2) or informational(3). |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.7.12.1.5 |
||||||
|
memDoorSensorConfigAlarmGenerationmandatory
Enable or disable alarm generation on this input.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.7.12.1.6 |
.1.3.6.1.4.1.318.1.1.10.4.7.14
·
1 row entry
·
8 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk memLeakRopeStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::memLeakRopeStatusTable'
Allows for access of individual leak ropes.
The leak rope to access.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
memLeakRopeStatusModuleIndexmandatory
The index of the leak rope entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.7.14.1.1 |
||||||
|
memLeakRopeStatusSensorIndexmandatory
The index of the leak rope sensor.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.7.14.1.2 |
||||||
|
memLeakRopeStatusSensorNamemandatory
The user defined name of the leak rope sensor.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.7.14.1.3 |
||||||
|
memLeakRopeStatusSensorLocationmandatory
The user-defined location of the leak rope sensor.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.4.7.14.1.4 |
||||||
|
memLeakRopeStatusSensorStatemandatory
The state of the leak rope sensor.
noleak (1) indicates there is no leak. leakdetected (2) indicates there is a detected leak. unknown (3) indicates the state is unknown. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.7.14.1.5 |
||||||
|
memLeakRopeStatusSensorSeveritymandatory
The severity of the alarm that will be triggered when
the leak rope sensor is activated. The alarms can be critical(1), warning(2) or informational(3). |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.7.14.1.6 |
||||||
|
memLeakRopeAlarmStatusmandatory
The alarm status of the rope link sensor.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.7.14.1.7 |
||||||
|
memLeakRopeCommStatusmandatory
The communication status of the rope link sensor.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.7.14.1.8 |
.1.3.6.1.4.1.318.1.1.10.4.7.15
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk memLeakRopeConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::memLeakRopeConfigTable'
Allows for the configuration of individual leak ropes.
The leak rope to configure.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
memLeakRopeConfigModuleIndexmandatory
The index of the leak rope module entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.7.15.1.1 |
||||||
|
memLeakRopeConfigSensorIndexmandatory
The index of the leak rope sensor entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.4.7.15.1.2 |
||||||
|
memLeakRopeConfigSensorNamemandatory
The user-defined name of the leak rope sensor.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.7.15.1.3 |
||||||
|
memLeakRopeConfigSensorLocationmandatory
The user-defined location of the leak rope sensor.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.4.7.15.1.4 |
||||||
|
memLeakRopeConfigSensorSeveritymandatory
The severity level of the leak rope sensor.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.7.15.1.5 |
||||||
|
memLeakRopeConfigAlarmGenerationmandatory
Enable or disable alarm generation on this input.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.4.7.15.1.6 |
.1.3.6.1.4.1.318.1.1.10.5.1.1
·
1 row entry
·
23 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk wirelessSensorStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::wirelessSensorStatusTable'
Allows for the access of individual sensors.
A list of wireless sensor status table entries.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
wirelessSensorStatusIndexmandatory
The index to the sensor entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.1.1.1.1 |
||||
|
wirelessSensorStatusExtAddrmandatory
The extended address is the combination of the unique 10 byte
MAC address of the sensor concatenated with its short address. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.5.1.1.1.2 |
||||
|
wirelessSensorStatusNamemandatory
The name of the wireless sensor.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.5.1.1.1.3 |
||||
|
wirelessSensorStatusAlarmGenerationmandatory
Indicates whether alarm generation is enabled or disabled for the sensor.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.5.1.1.1.4 |
||||
|
wirelessSensorStatusTemperaturemandatory
The current temperature are displayed in tenths of degrees in the scale
shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.1.1.1.5 |
||||
|
wirelessSensorStatusHighTempThreshmandatory
Values are displayed in tenths of degrees in the scale
shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.1.1.1.6 |
||||
|
wirelessSensorStatusLowTempThreshmandatory
Values are displayed in tenths of degrees in the scale
shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.1.1.1.7 |
||||
|
wirelessSensorStatusHumiditymandatory
Values are represented in whole number percentage.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.1.1.1.8 |
||||
|
Values are represented in whole number percentage.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.1.1.1.9 |
||||
|
Values are represented in whole number percentage.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.1.1.1.10 |
||||
|
wirelessSensorStatusCommStatusmandatory
The communication status of the wireless sensor.
inactive(0) indicates sensor is in the wireless network but not sending information. active(1) indicates wireless sensor is live and sending information. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.5.1.1.1.11 |
||||
|
wirelessSensorStatusMaxTempThreshmandatory
Values are displayed in tenths of degrees in the scale
shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.1.1.1.12 |
||||
|
wirelessSensorStatusMinTempThreshmandatory
Values are displayed in tenths of degrees in the scale
shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.1.1.1.13 |
||||
|
Values are represented in whole number percentage.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.1.1.1.14 |
||||
|
Values are represented in whole number percentage.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.1.1.1.15 |
||||
|
wirelessSensorStatusBatterymandatory
Values are displayed in tenths of Volts DC.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.1.1.1.16 |
||||
|
wirelessSensorStatusLowBatteryThreshmandatory
Values are displayed in tenths of Volts DC.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.1.1.1.17 |
||||
|
wirelessSensorStatusMinBatteryThreshmandatory
Values are displayed in tenths of Volts DC.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.1.1.1.18 |
||||
|
wirelessSensorStatusRssimandatory
Values are represented in whole number percentage.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.1.1.1.19 |
||||
|
wirelessSensorStatusLowRssiThreshmandatory
Values are represented in whole number percentage.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.1.1.1.20 |
||||
|
wirelessSensorStatusMinRssiThreshmandatory
Values are represented in whole number percentage.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.1.1.1.21 |
||||
|
wirelessSensorStatusLocationmandatory
A user-defined string identifying the location
of the wireless sensor. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.5.1.1.1.22 |
||||
|
wirelessSensorStatusAlarmStatusmandatory
The alarm status of the wireless sensor. This integer should be interpreted
as a bit map, with each bit representing the presence or absence of the specific alarm conditions listed below. The bit will be '1' if the co… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.1.1.1.23 |
.1.3.6.1.4.1.318.1.1.10.5.2.1
·
1 row entry
·
26 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk wirelessSensorPodStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::wirelessSensorPodStatusTable'
Allows for the access of individual pod sensors.
The sensor pod to access.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
wirelessSensorPodStatusIndexmandatory
The index to the pod sensor entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.2.1.1.1 |
||||
|
wirelessSensorPodPortIndexmandatory
The pod sensor port index.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.2.1.1.2 |
||||
|
wirelessSensorPodStatusExtAddrmandatory
The extended address is the combination of the unique 10 byte MAC address
of the sensor concatenated with its short address. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.5.2.1.1.3 |
||||
|
wirelessSensorPodStatusNamemandatory
The name of the sensor pod.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.5.2.1.1.4 |
||||
|
Status of whether alarm generation is enabled or disabled.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.5.2.1.1.5 |
||||
|
wirelessSensorPodStatusTemperaturemandatory
Values are displayed in tenths of degrees in the scale
shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.2.1.1.6 |
||||
|
Values are displayed in tenths of degrees in the scale
shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.2.1.1.7 |
||||
|
wirelessSensorPodStatusLowTempThreshmandatory
Values are displayed in tenths of degrees in the scale
shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.2.1.1.8 |
||||
|
wirelessSensorPodStatusHumiditymandatory
Values are represented in whole number percentage.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.2.1.1.9 |
||||
|
Values are represented in whole number percentage.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.2.1.1.10 |
||||
|
Values are represented in whole number percentage.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.2.1.1.11 |
||||
|
wirelessSensorPodStatusCommStatusmandatory
The communication status of the wireless sensor.
inactive(0) indicates pod sensor is in the wireless network but not sending information. active(1) indicates wireless sensor is live and sending information. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.5.2.1.1.12 |
||||
|
wirelessSensorPodStatusMaxTempThreshmandatory
Values are displayed in tenths of degrees in the scale
shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.2.1.1.13 |
||||
|
wirelessSensorPodStatusMinTempThreshmandatory
Values are displayed in tenths of degrees in the scale
shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.2.1.1.14 |
||||
|
Values are represented in whole number percentage.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.2.1.1.15 |
||||
|
Values are represented in whole number percentage.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.2.1.1.16 |
||||
|
State of the dry contact. If the dry contact is closed,
the drycontactClosed (1) value will be returned. If the dry contact state is open, the drycontactOpen (0) value will be returned. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.5.2.1.1.17 |
||||
|
The normal state of the dry contact. If the normal state is closed,
the normallyClosed (1) value will be returned. If the normal state is open, the normallyOpen (0) value will be returned. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.5.2.1.1.18 |
||||
|
wirelessSensorPodStatusBatterymandatory
Values are displayed in tenths of Volts DC.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.2.1.1.19 |
||||
|
Values are displayed in tenths of Volts DC.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.2.1.1.20 |
||||
|
Values are displayed in tenths of Volts DC.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.2.1.1.21 |
||||
|
wirelessSensorPodStatusRssimandatory
Values are represented in whole number percentage.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.2.1.1.22 |
||||
|
wirelessSensorPodStatusLowRssiThreshmandatory
Values are represented in whole number percentage.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.2.1.1.23 |
||||
|
wirelessSensorPodStatusMinRssiThreshmandatory
Values are represented in whole number percentage.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.2.1.1.24 |
||||
|
wirelessSensorPodStatusLocationmandatory
The location of the wireless sensor pod.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.5.2.1.1.25 |
||||
|
wirelessSensorPodStatusAlarmStatusmandatory
The alarm status of the wireless pod sensor. This integer should be interpreted
as a bit map, with each bit representing the presence or absence of the specific alarm conditions listed below. The bit will be '1' if th… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.2.1.1.26 |
.1.3.6.1.4.1.318.1.1.10.5.3.1
·
1 row entry
·
16 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk wirelessSensorConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::wirelessSensorConfigTable'
Allows for the configuration of individual sensors.
The sensor to configure.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
wirelessSensorConfigIndexmandatory
The index to the entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.3.1.1.1 |
||||
|
wirelessSensorConfigNamemandatory
The user-defined wireless sensor ID string.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.5.3.1.1.2 |
||||
|
wirelessSensorConfigAlarmGenerationmandatory
Enable or disable alarm generation for this sensor.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.5.3.1.1.3 |
||||
|
wirelessSensorConfigHighTempThreshmandatory
Values are displayed in tenths of degrees in the scale
shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.3.1.1.4 |
||||
|
wirelessSensorConfigLowTempThreshmandatory
Values are displayed in tenths of degrees in the scale
shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.3.1.1.5 |
||||
|
Values are represented in whole number percentage.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.3.1.1.6 |
||||
|
Values are represented in whole number percentage.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.3.1.1.7 |
||||
|
wirelessSensorConfigMaxTempThreshmandatory
Values are displayed in tenths of degrees in the scale
shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.3.1.1.8 |
||||
|
wirelessSensorConfigMinTempThreshmandatory
Values are displayed in tenths of degrees in the scale
shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.3.1.1.9 |
||||
|
Values are represented in whole number percentage.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.3.1.1.10 |
||||
|
Values are represented in whole number percentage.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.3.1.1.11 |
||||
|
wirelessSensorConfigLowBatteryThreshmandatory
Values are displayed in tenths of Volts DC.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.3.1.1.12 |
||||
|
wirelessSensorConfigMinBatteryThreshmandatory
Values are displayed in tenths of Volts DC.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.3.1.1.13 |
||||
|
wirelessSensorConfigLowRssiThreshmandatory
Values are represented in whole number percentage.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.3.1.1.14 |
||||
|
wirelessSensorConfigMinRssiThreshmandatory
Values are represented in whole number percentage.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.3.1.1.15 |
||||
|
wirelessSensorConfigLocationmandatory
A user-defined string identifying the location of the
wireless sensor. Maximum text input is 20 characters. |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.5.3.1.1.16 |
.1.3.6.1.4.1.318.1.1.10.5.4.1
·
1 row entry
·
18 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk wirelessSensorPodConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::wirelessSensorPodConfigTable'
Allows for the configuration of individual sensors.
The sensor to configure.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
wirelessSensorPodConfigIndexmandatory
The index to the entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.4.1.1.1 |
||||
|
wirelessSensorPodConfigPortIndexmandatory
The sensor pod port index.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.4.1.1.2 |
||||
|
wirelessSensorPodConfigNamemandatory
The user defined name of the sensor pod.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.5.4.1.1.3 |
||||
|
Enable or disable alarm generation for this sensor.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.5.4.1.1.4 |
||||
|
The normal state of the dry contact. If the normal state is closed,
the normallyClosed (1) value will be returned. If the normal state is open, the normallyOpen (0) value will be returned. Setting this variable will cha… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.10.5.4.1.1.5 |
||||
|
Values are displayed in tenths of degrees in the scale
shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.4.1.1.6 |
||||
|
wirelessSensorPodConfigLowTempThreshmandatory
Values are displayed in tenths of degrees in the scale
shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.4.1.1.7 |
||||
|
Values are represented in whole number percentage.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.4.1.1.8 |
||||
|
Values are represented in whole number percentage.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.4.1.1.9 |
||||
|
wirelessSensorPodConfigMaxTempThreshmandatory
Values are displayed in tenths of degrees in the scale
shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.4.1.1.10 |
||||
|
wirelessSensorPodConfigMinTempThreshmandatory
Values are represented in whole number degrees.
Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.4.1.1.11 |
||||
|
Values are represented in whole number percentage.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.4.1.1.12 |
||||
|
Values are represented in whole number percentage.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.4.1.1.13 |
||||
|
Values are displayed in tenths of Volts DC.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.4.1.1.14 |
||||
|
Values are displayed in tenths of Volts DC.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.4.1.1.15 |
||||
|
wirelessSensorPodConfigLowRssiThreshmandatory
Values are represented in whole number percentage.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.4.1.1.16 |
||||
|
wirelessSensorPodConfigMinRssiThreshmandatory
Values are represented in whole number percentage.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.10.5.4.1.1.17 |
||||
|
wirelessSensorPodConfigLocationmandatory
A user-defined string identifying the location of the
wireless pod sensor. Maximum text input is 20 characters. |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.10.5.4.1.1.18 |
.1.3.6.1.4.1.318.1.1.12.2.1.6
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDULoadDevBankTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDULoadDevBankTable'
Allows for getting the Bank Max Load in the Rack PDU.
The Rack PDU Banks Access.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
rPDULoadDevBankIndexmandatory
The index to the Rack PDU bank entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.12.2.1.6.1.1 |
|
rPDULoadDevBankNumbermandatory
Getting this OID will return the bank number.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.12.2.1.6.1.2 |
|
rPDULoadDevBankMaxLoadmandatory
Getting this OID will return the maximum rated power
that each bank of the Rack PDU can provide. It is represented in Amps. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.12.2.1.6.1.3 |
.1.3.6.1.4.1.318.1.1.12.2.1.8
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDULoadDevMaxOutletTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDULoadDevMaxOutletTable'
Allows for getting the Max Outlet Load in an Outlet Monitored Rack PDU.
This gives access to Max Outlet Load of an Outlet Monitored Rack PDU
Indexes
| Column | Syntax | OID |
|---|---|---|
|
rPDULoadDevOutletIndexmandatory
The index to the Outlet Monitored Rack PDU Max Outlet Load entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.12.2.1.8.1.1 |
|
rPDULoadDevOutletNumbermandatory
Getting this OID will return the Outlet number.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.12.2.1.8.1.2 |
|
rPDULoadDevMaxOutletLoadmandatory
Getting this OID will return the maximum rated power
that each Outlet of an Outlet Monitored Rack PDU can provide. It is represented in Amps. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.12.2.1.8.1.3 |
.1.3.6.1.4.1.318.1.1.12.2.2.1
·
1 row entry
·
5 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDULoadPhaseConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDULoadPhaseConfigTable'
Allows for configuration of each Rack PDU phase. The number of entries is contained in the rPDULoadDevNumPhases OID.
The Rack PDU phase to configure.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
rPDULoadPhaseConfigIndexmandatory
The index to the Rack PDU phase entry.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.12.2.2.1.1.1 |
||||||||
|
rPDULoadPhaseConfigLowLoadThresholdmandatory
A threshold that indicates the power consumption of
the load is nearing a low consumption condition. It is represented in Amps. A warning will be issued when the load is less than the threshold value. A … |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.12.2.2.1.1.2 |
||||||||
|
A threshold that indicates the power consumption of
the load is nearing an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. … |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.12.2.2.1.1.3 |
||||||||
|
rPDULoadPhaseConfigOverloadThresholdmandatory
A threshold that indicates the power consumption of
the load has entered an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. … |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.12.2.2.1.1.4 |
||||||||
|
rPDULoadPhaseConfigAlarmmandatory
Getting this OID will return the current Phase Alarm.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.12.2.2.1.1.5 |
.1.3.6.1.4.1.318.1.1.12.2.3.1
·
1 row entry
·
5 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDULoadStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDULoadStatusTable'
Allows for getting of status of each Rack PDU phase/bank. The number of entries is calculated by adding the number of phases (rPDULoadDevNumPhases OID) and the number of banks of outlets (rPDULoadDevNumBanks) Number of entries = #phases + #banks. NOTE: If a device has phase and bank information, all phase information shall precede the bank information. If a device has total information, it shall precede both the bank and the phase information.
The Rack PDU phase/bank to gather status from.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
rPDULoadStatusIndexmandatory
The index to the Rack PDU phase/bank entry. All phase information will precede
any bank information |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.12.2.3.1.1.1 |
||||||||
|
rPDULoadStatusLoadmandatory
Getting this OID will return the phase/bank load measured
in tenths of Amps. |
RFC1155-SMIGauge Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.318.1.1.12.2.3.1.1.2 |
||||||||
|
rPDULoadStatusLoadStatemandatory
Getting this OID will return the phase/bank load state.
phaseLoadNormal(1) indicates that the phase/bank is operating properly within the rPDULoadConfigLowLoadThreshold and rPDULoadConfigNearOverloadThres… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.12.2.3.1.1.3 |
||||||||
|
rPDULoadStatusPhaseNumbermandatory
The phase number to which this record refers.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.12.2.3.1.1.4 |
||||||||
|
rPDULoadStatusBankNumbermandatory
The bank number to which this record refers. A value of 0 will be returned if
any bank is not present or if it is phase related. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.12.2.3.1.1.5 |
.1.3.6.1.4.1.318.1.1.12.2.4.1
·
1 row entry
·
5 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDULoadBankConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDULoadBankConfigTable'
Allows for configuration of each Rack PDU bank. The number of entries is contained in the rPDULoadDevNumBanks OID.
The Rack PDU bank to configure.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
rPDULoadBankConfigIndexmandatory
The index to the Rack PDU bank entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.12.2.4.1.1.1 |
||||||||
|
rPDULoadBankConfigLowLoadThresholdmandatory
A threshold that indicates the power consumption of
the load is nearing a low consumption condition. It is represented in Amps. A warning will be issued when the load is less than the threshold value. A … |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.12.2.4.1.1.2 |
||||||||
|
A threshold that indicates the power consumption of
the load is nearing an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. … |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.12.2.4.1.1.3 |
||||||||
|
rPDULoadBankConfigOverloadThresholdmandatory
A threshold that indicates the power consumption of
the load has entered an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. … |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.12.2.4.1.1.4 |
||||||||
|
rPDULoadBankConfigAlarmmandatory
Getting this OID will return the current Bank Alarm.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.12.2.4.1.1.5 |
.1.3.6.1.4.1.318.1.1.12.3.2.1
·
1 row entry
·
2 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDUOutletPhaseTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDUOutletPhaseTable'
Allows for management of outlets on a per phase basis.
The phase to manage.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
rPDUOutletPhaseIndexmandatory
The index to the Switched Rack PDU phase entry.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.12.3.2.1.1.1 |
||||||
|
rPDUOutletPhaseOverloadRestrictionmandatory
This OID controls the behavior of a Switched Rack PDU
phase when an overload condition is possible and additional outlets are requested to be turned on. Setting this OID to alwaysAllowTurnON (1) will alwa… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.12.3.2.1.1.2 |
.1.3.6.1.4.1.318.1.1.12.3.3.1
·
1 row entry
·
5 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDUOutletControlTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDUOutletControlTable'
Allows for control of the individual outlets. The number of entries is contained in the rPDUOutletDevNumCntrlOutlets OID.
The outlet to control.
Indexes
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
rPDUOutletControlIndexmandatory
The index to the outlet entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.12.3.3.1.1.1 |
||||||||||||||
|
rPDUOutletControlOutletNamemandatory
The name of the outlet. The maximum string size is device dependent.
An error will be returned if the set request exceeds the max size. This OID is provided for informational purposes only. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.12.3.3.1.1.2 |
||||||||||||||
|
rPDUOutletControlOutletPhasemandatory
The phase/s associated with this outlet.
For single phase devices, this object will always return phase1(1). For 3-phase devices, this object will return phase1 (1), phase2 (2), or phase3 (… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.12.3.3.1.1.3 |
||||||||||||||
|
rPDUOutletControlOutletCommandmandatory
Getting this variable will return the outlet state. If
the outlet is on, the immediateOn (1) value will be returned. If the outlet is off, the immediateOff (2) value will be returned. Setti… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.12.3.3.1.1.4 |
||||||||||||||
|
rPDUOutletControlOutletBankmandatory
The bank associated with this outlet.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.12.3.3.1.1.5 |
.1.3.6.1.4.1.318.1.1.12.3.4.1
·
1 row entry
·
7 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDUOutletConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDUOutletConfigTable'
Allows for configuration of individual outlets. The number of entries is contained in the rPDUOutletDevNumCntrlOutlets OID.
The outlet to configure.
Indexes
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
rPDUOutletConfigIndexmandatory
The index to the outlet entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.12.3.4.1.1.1 |
||||||||||||
|
rPDUOutletConfigOutletNamemandatory
The name of the outlet. The maximum string size is device dependent.
An error will be returned if the set request exceeds the max size. |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.12.3.4.1.1.2 |
||||||||||||
|
rPDUOutletConfigOutletPhasemandatory
The phase/s associated with this outlet.
For single phase devices, this object will always return phase1(1). For 3-phase devices, this object will return phase1 (1), phase2 (2), or phase3 (… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.12.3.4.1.1.3 |
||||||||||||
|
rPDUOutletConfigPowerOnTimemandatory
The amount of time (in seconds) the outlet will delay
powering on at coldstart or when a command that requires a turn-on delay is issued. Allowed values are: -1 - never power on. 0 … |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.12.3.4.1.1.4 |
||||||||||||
|
rPDUOutletConfigPowerOffTimemandatory
The amount of time (in seconds) the outlet will delay
powering off when a command that requires a turn-off delay is issued. Allowed values are: -1 - never power off. 0 - powe… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.12.3.4.1.1.5 |
||||||||||||
|
rPDUOutletConfigRebootDurationmandatory
During a reboot sequence, power is turned off and then
back on. This OID defines the amount of time to wait, in seconds, after turning the power off, at the start of the sequence, before turning power back on, at the en… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.12.3.4.1.1.6 |
||||||||||||
|
rPDUOutletConfigOutletBankmandatory
The bank associated with this outlet.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.12.3.4.1.1.7 |
.1.3.6.1.4.1.318.1.1.12.3.4.3
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDUOutletConfigMonitoredTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDUOutletConfigMonitoredTable'
Allows for getting/setting of outlet thresholds of an Outlet Monitored Rack PDU.
This gives access to Monitored Outlet entries
Indexes
| Column | Syntax | OID |
|---|---|---|
|
rPDUOutletConfigMonitoredIndexmandatory
The index to the RACK PDU Phase entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.12.3.4.3.1.1 |
|
rPDUOutletConfigMonitoredNamemandatory
The name of the Monitored Outlet. The maximum string size is device dependent.
An error will be returned if the set request exceeds the max size. |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.12.3.4.3.1.2 |
|
rPDUOutletConfigMonitoredNumbermandatory
The outlet number of an Outlet Monitored RACK PDU.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.12.3.4.3.1.3 |
|
A threshold that indicates the power consumption of
the load is nearing a low consumption condition. It is represented in Amps. A warning will be issued when the load is less than the threshold value. A … |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.12.3.4.3.1.4 |
|
A threshold that indicates the power consumption of
the load is nearing an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. … |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.12.3.4.3.1.5 |
|
A threshold that indicates the power consumption of
the load has entered an overload condition. It is represented in Amps. A warning will be issued when the load is greater than or equal to the threshold value. … |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.12.3.4.3.1.6 |
.1.3.6.1.4.1.318.1.1.12.3.5.1
·
1 row entry
·
7 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDUOutletStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDUOutletStatusTable'
Allows for getting of status of individual outlets. The number of entries is contained in the rPDUOutletDevNumCntrlOutlets OID or rPDUOutletDevMonitoredOutlets OID.
The outlet to gather status from.
Indexes
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
rPDUOutletStatusIndexmandatory
The index to the outlet entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.12.3.5.1.1.1 |
||||||||||||
|
rPDUOutletStatusOutletNamemandatory
The name of the outlet. The maximum string size is device dependent.
This OID is provided for informational purposes only. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.12.3.5.1.1.2 |
||||||||||||
|
rPDUOutletStatusOutletPhasemandatory
The phase/s associated with this outlet.
For single phase devices, this object will always return phase1(1). For 3-phase devices, this object will return phase1 (1), phase2 (2), or phase3 (… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.12.3.5.1.1.3 |
||||||||||||
|
rPDUOutletStatusOutletStatemandatory
Getting this variable will return the outlet state. If
the outlet is on, the outletStatusOn (1) value will be returned. If the outlet is off, the outletStatusOff (2) value will be returned. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.12.3.5.1.1.4 |
||||||||||||
|
rPDUOutletStatusCommandPendingmandatory
Getting this variable will return the command pending
state of the outlet. If a command is pending on the outlet, the outletStatusCommandPending (1) value will be returned. If there is not a command pending on the outle… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.12.3.5.1.1.5 |
||||||||||||
|
rPDUOutletStatusOutletBankmandatory
The bank associated with this outlet.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.12.3.5.1.1.6 |
||||||||||||
|
rPDUOutletStatusLoadmandatory
Getting this OID will return the measured Outlet load for
an Outlet Monitored Rack PDU in tenths of Amps. For other models this OID is not supported. |
RFC1155-SMIGauge Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.318.1.1.12.3.5.1.1.7 |
.1.3.6.1.4.1.318.1.1.12.3.6.1
·
1 row entry
·
2 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDUOutletBankTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDUOutletBankTable'
Allows for management of outlets on a per bank basis.
The bank to manage.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
rPDUOutletBankIndexmandatory
The index to the Switched Rack PDU bank entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.12.3.6.1.1.1 |
||||||
|
rPDUOutletBankOverloadRestrictionmandatory
This OID controls the behavior of a Switched Rack PDU
bank when an overload condition is possible and additional outlets are requested to be turned on. Setting this OID to alwaysAllowTurnON (1) will alway… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.12.3.6.1.1.2 |
.1.3.6.1.4.1.318.1.1.12.5.2
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDUStatusBankTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDUStatusBankTable'
Allows for getting of status of each Rack PDU Bank
This gives access to Bank entries
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
rPDUStatusBankIndexmandatory
The index to the RACK PDU Bank entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.12.5.2.1.1 |
||||||||
|
rPDUStatusBankNumbermandatory
Getting this OID will return the bank number.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.12.5.2.1.2 |
||||||||
|
rPDUStatusBankStatemandatory
Getting this OID will return the bank load state.
bankLoadNormal(1) indicates that the bank is operating properly within the rPDULoadBankConfigLowLoadThreshold and rPDULoadBankConfigNearOverloadThreshold … |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.12.5.2.1.3 |
.1.3.6.1.4.1.318.1.1.12.5.4
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDUStatusPhaseTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDUStatusPhaseTable'
Allows for getting of status of each Rack PDU Phase
This gives access to Phase entries
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
rPDUStatusPhaseIndexmandatory
The index to the RACK PDU Phase entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.12.5.4.1.1 |
||||||||
|
rPDUStatusPhaseNumbermandatory
Getting this OID will return the phase number.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.12.5.4.1.2 |
||||||||
|
rPDUStatusPhaseStatemandatory
Getting this OID will return the Phase load state.
phaseLoadNormal(1) indicates that the Phase is operating properly within the rPDULoadPhaseConfigLowLoadThreshold and rPDULoadPhaseConfigNearOverloadThres… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.12.5.4.1.3 |
.1.3.6.1.4.1.318.1.1.12.5.6
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDUStatusOutletTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDUStatusOutletTable'
Allows for getting of status of each Outlet of an Outlet Monitored Rack PDU.
This gives access to Outlet entries
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
rPDUStatusOutletIndexmandatory
The index to the RACK PDU Outlet entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.12.5.6.1.1 |
||||||||
|
rPDUStatusOutletNumbermandatory
Getting this OID will return the Outlet number.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.12.5.6.1.2 |
||||||||
|
rPDUStatusOutletStatemandatory
Getting this OID will return the Outlet load state.
outletLoadNormal(1) indicates that the Outlet is operating properly within the rPDUOutletConfigMonitoredLowLoadThreshold and rPDUOutletConfigMonitoredNe… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.12.5.6.1.3 |
.1.3.6.1.4.1.318.1.1.13.1.1.3
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airFMIdentTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airFMIdentTable'
Allows for getting identification information from each module in the system.
The module to get information from.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
airFMIdentModuleIndexmandatory
The index of the module information.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.1.3.1.1 |
|
airFMIdentModuleModelNumbermandatory
A character string identifying the
model number. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.13.1.1.3.1.2 |
|
airFMIdentModuleDateOfMfgmandatory
A character string identifying the
manufacture date. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.13.1.1.3.1.3 |
|
airFMIdentModuleSerialNumbermandatory
A character string identifying the
unit serial number. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.13.1.1.3.1.4 |
|
airFMIdentModuleFirmwareRevmandatory
A character string identifying the
firmware revision. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.13.1.1.3.1.5 |
|
airFMIdentModuleHardwareRevmandatory
A character string identifying the
hardware revision. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.13.1.1.3.1.6 |
.1.3.6.1.4.1.318.1.1.13.1.2.20
·
1 row entry
·
8 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airFMStatusModuleTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airFMStatusModuleTable'
Allows for getting information from each module in the system.
The module to get status from.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
airFMStatusModuleIndexmandatory
The index of the module information.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.2.20.1.1 |
|
airFMStatusModuleOutputCapacitymandatory
The module output capacity in kilowatts.
This OID has been deprecated in favor of airFMModOutputCapacity. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.2.20.1.2 |
|
airFMStatusModuleSupplyTempCmandatory
The module supply air temperature in
tenths of degrees Celsius. This OID has been deprecated in favor of airFMModSupplyTempC. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.2.20.1.3 |
|
airFMStatusModuleSupplyTempFmandatory
The module supply air temperature in
tenths of degrees Fahrenheit. This OID has been deprecated in favor of airFMModSupplyTempF. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.2.20.1.4 |
|
airFMStatusModuleSupplyHummandatory
The module supply air humidity in tenths of percent RH.
This OID has been deprecated in favor of airFMModSupplyHum. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.2.20.1.5 |
|
airFMStatusModuleReturnTempCmandatory
The module return air temperature in
tenths of degrees Celsius. This OID has been deprecated in favor of airFMModReturnTempC. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.2.20.1.6 |
|
airFMStatusModuleReturnTempFmandatory
The module return air temperature in
tenths of degrees Fahrenheit. This OID has been deprecated in favor of airFMModReturnTempF. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.2.20.1.7 |
|
airFMStatusModuleReturnHummandatory
The module return air humidity in tenths of percent RH.
This OID has been deprecated in favor of airFMModReturnHum. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.2.20.1.8 |
.1.3.6.1.4.1.318.1.1.13.1.3.4.2
·
1 row entry
·
7 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airFMGroupSysRolesTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airFMGroupSysRolesTable'
Allows for getting information from each system in the group.
The system to get status from.
Indexes
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
airFMGroupSysIndexmandatory
The index of the system information.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.3.4.2.1.1 |
||||||||||||||
|
airFMGroupSysRoleStatusmandatory
The present mode of the System.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.3.4.2.1.2 |
||||||||||||||
|
airFMGroupSysPresentRolemandatory
The present role of the System in a Group.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.3.4.2.1.3 |
||||||||||||||
|
airFMGroupSysManualRoleSettingmandatory
The manual role setting of the System in a Group.
Only applies if Role Assignment Method is set to static (Manually Assigned Roles). |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.3.4.2.1.4 |
||||||||||||||
|
airFMGroupSysRunHoursmandatory
The total number of hours the System has been
contributing to environmental control. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.3.4.2.1.5 |
||||||||||||||
|
airFMGroupSysCommmandatory
Indicates whether a system is communicating with the
other Systems in the Group. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.3.4.2.1.6 |
||||||||||||||
|
airFMGroupSysIPAddressmandatory
The IP Address of the System.
|
RFC1155-SMIIpAddress Type Constraints: range: 4 |
.1.3.6.1.4.1.318.1.1.13.1.3.4.2.1.7 |
.1.3.6.1.4.1.318.1.1.13.1.4.10.2
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airFMSysInputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airFMSysInputTable'
Allows for getting information from each input contact.
The input contact to obtain status from.
Indexes
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
airFMSysInputIndexmandatory
The number designator of the Input Contact.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.4.10.2.1.1 |
||||||||||||
|
airFMSysInputNamemandatory
The configurable name for the Input Contact. Maximum
text input is 13 characters. |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.13.1.4.10.2.1.2 |
||||||||||||
|
airFMSysInputStatusmandatory
The state of this contact: Open or Closed. A
violation will occur when this relay is not in its normal state. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.10.2.1.3 |
||||||||||||
|
airFMSysInputNormalStatemandatory
Set the normal state of this contact (the state when
no alarm/event exists). |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.10.2.1.4 |
||||||||||||
|
airFMSysInputDelaymandatory
Set the delay between this contact exiting its normal
state and an alarm being triggered. Measured in seconds. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.4.10.2.1.5 |
||||||||||||
|
airFMSysInputAlarmActionmandatory
Sets the behavior for this contact when it exits its
normal state. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.10.2.1.6 |
.1.3.6.1.4.1.318.1.1.13.1.4.11.2
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airFMSysOutputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airFMSysOutputTable'
Allows for getting information from each output relay.
The output relay to obtain status from.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
airFMSysOutputIndexmandatory
The number designator of the output relay.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.4.11.2.1.1 |
||||
|
airFMSysOutputStatusmandatory
The state of this relay: Open or Closed. A violation
will occur when this relay is not in its normal state. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.11.2.1.2 |
||||
|
airFMSysOutputNormalStatemandatory
Set the normal state of this relay (the state when no
alarm/event exists). |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.11.2.1.3 |
.1.3.6.1.4.1.318.1.1.13.1.4.12.1.2
·
1 row entry
·
17 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airFMSysAlarmMapSysTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airFMSysAlarmMapSysTable'
Allows for getting alarm map information.
The system alarm map type to reference.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
airFMSysAlarmMapSysOutputIndexmandatory
The index of the output relay.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.1 |
||||||
|
airFMSysAlarmMapSysAnyAlarmmandatory
System alarm map setting for Any Alarm.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.2 |
||||||
|
airFMSysAlarmMapSystemOnmandatory
System alarm map setting for System On.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.3 |
||||||
|
airFMSysAlarmMapSystemOfflinemandatory
System alarm map setting for System Offline.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.4 |
||||||
|
airFMSysAlarmMapSysHighEnvTempmandatory
System alarm map setting for High Environmental
Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.5 |
||||||
|
airFMSysAlarmMapSysLowEnvTempmandatory
System alarm map setting for Low Environmental
Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.6 |
||||||
|
airFMSysAlarmMapSysHighEnvHummandatory
System alarm map setting for High Environmental
Humidity. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.7 |
||||||
|
airFMSysAlarmMapSysLowEnvHummandatory
System alarm map setting for Low Environmental
Humidity. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.8 |
||||||
|
airFMSysAlarmMapSysFireDetmandatory
System alarm map setting for Fire Detected.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.9 |
||||||
|
airFMSysAlarmMapSysSmokeDetmandatory
System alarm map setting for Smoke Detected.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.10 |
||||||
|
airFMSysAlarmMapSysEconIsolmandatory
System alarm map setting for Econ Isolator.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.11 |
||||||
|
airFMSysAlarmMapSysSupplySensFailmandatory
System alarm map setting for Supply Sensor Failure.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.12 |
||||||
|
airFMSysAlarmMapSysReturnSensFailmandatory
System alarm map setting for Return Sensor Failure.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.13 |
||||||
|
airFMSysAlarmMapSysRemSensRemovedmandatory
System alarm map setting for Remote Sensor Removed.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.14 |
||||||
|
airFMSysAlarmMapSysPrimSensFailmandatory
System alarm map setting for Primary Sensor Failure.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.15 |
||||||
|
airFMSysAlarmMapSysSecSensFailmandatory
System alarm map setting for Secondary Sensor Failure.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.16 |
||||||
|
airFMSysAlarmMapSysSecSensActivemandatory
System alarm map setting for Secondary Sensor Active.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.1.2.1.17 |
.1.3.6.1.4.1.318.1.1.13.1.4.12.2.2
·
1 row entry
·
15 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airFMSysAlarmMapMainModTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airFMSysAlarmMapMainModTable'
Allows for getting alarm map information.
The main module alarm map type to reference.
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
airFMSysAlarmMapMainModOutputIndexmandatory
The index of the output relay.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.1 |
||||||
|
airFMSysAlarmMapMainModAnyAlarmmandatory
Main Module alarm map setting for Any Alarm.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.2 |
||||||
|
airFMSysAlarmMapMainModMaintReqmandatory
Main Module alarm map setting for Module Maintenance
Required. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.3 |
||||||
|
airFMSysAlarmMapMainModCoolFailmandatory
Main Module alarm map setting for Module Cooling
Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.4 |
||||||
|
Main Module alarm map setting for High Supply
Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.5 |
||||||
|
airFMSysAlarmMapMainModLowSupplyTempmandatory
Main Module alarm map setting for Low Supply
Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.6 |
||||||
|
airFMSysAlarmMapMainModHumFailmandatory
Main Module alarm map setting for Humidifier Failure.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.7 |
||||||
|
airFMSysAlarmMapMainModHumReplCylmandatory
Main Module alarm map setting for Humidifier Replace
Cylinder. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.8 |
||||||
|
airFMSysAlarmMapMainModCondPumpFailmandatory
Main Module alarm map setting for Condensate Pump
Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.9 |
||||||
|
airFMSysAlarmMapMainModBlwrCntl1Failmandatory
Main Module alarm map setting for Blower Controller 1
Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.10 |
||||||
|
airFMSysAlarmMapMainModBlwrCntl2Failmandatory
Main Module alarm map setting for Blower Controller 2
Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.11 |
||||||
|
airFMSysAlarmMapMainModHighFltrDPmandatory
Main Module alarm map setting for High Filter
Differential Pressure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.12 |
||||||
|
airFMSysAlarmMapMainModLowAirFlowmandatory
Main Module alarm map setting for Low Air Flow.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.13 |
||||||
|
Main Module alarm map setting for Air Block Interlock
Open. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.14 |
||||||
|
airFMSysAlarmMapMainModWaterDetectedmandatory
Main Module alarm map setting for Water Detected.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.2.2.1.15 |
.1.3.6.1.4.1.318.1.1.13.1.4.12.3.2
·
1 row entry
·
15 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airFMSysAlarmMapExpMod1Table
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airFMSysAlarmMapExpMod1Table'
Allows for getting alarm map information.
The expansion module 1 alarm map type to reference.
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
airFMSysAlarmMapExpMod1OutputIndexmandatory
The index of the output relay.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.1 |
||||||
|
airFMSysAlarmMapExpMod1AnyAlarmmandatory
Exp Module 1 alarm map setting for Any Alarm.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.2 |
||||||
|
airFMSysAlarmMapExpMod1MaintReqmandatory
Exp Module 1 alarm map setting for Module Maintenance
Required. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.3 |
||||||
|
airFMSysAlarmMapExpMod1CoolFailmandatory
Exp Module 1 alarm map setting for Module Cooling
Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.4 |
||||||
|
Exp Module 1 alarm map setting for High Supply
Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.5 |
||||||
|
airFMSysAlarmMapExpMod1LowSupplyTempmandatory
Exp Module 1 alarm map setting for Low Supply
Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.6 |
||||||
|
airFMSysAlarmMapExpMod1HumFailmandatory
Exp Module 1 alarm map setting for Humidifier Failure.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.7 |
||||||
|
airFMSysAlarmMapExpMod1HumReplCylmandatory
Exp Module 1 alarm map setting for Humidifier Replace
Cylinder. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.8 |
||||||
|
airFMSysAlarmMapExpMod1CondPumpFailmandatory
Exp Module 1 alarm map setting for Condensate Pump
Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.9 |
||||||
|
airFMSysAlarmMapExpMod1BlwrCntl1Failmandatory
Exp Module 1 alarm map setting for Blower Controller 1
Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.10 |
||||||
|
airFMSysAlarmMapExpMod1BlwrCntl2Failmandatory
Exp Module 1 alarm map setting for Blower Controller 2
Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.11 |
||||||
|
airFMSysAlarmMapExpMod1HighFltrDPmandatory
Exp Module 1 alarm map setting for High Filter
Differential Pressure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.12 |
||||||
|
airFMSysAlarmMapExpMod1LowAirFlowmandatory
Exp Module 1 alarm map setting for Low Air Flow.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.13 |
||||||
|
Exp Module 1 alarm map setting for Air Block Interlock
Open. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.14 |
||||||
|
airFMSysAlarmMapExpMod1WaterDetectedmandatory
Exp Module 1 alarm map setting for Water Detected.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.3.2.1.15 |
.1.3.6.1.4.1.318.1.1.13.1.4.12.4.2
·
1 row entry
·
15 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airFMSysAlarmMapExpMod2Table
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airFMSysAlarmMapExpMod2Table'
Allows for getting alarm map information.
The expansion module 2 alarm map type to reference.
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
airFMSysAlarmMapExpMod2OutputIndexmandatory
The index of the output relay.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.1 |
||||||
|
airFMSysAlarmMapExpMod2AnyAlarmmandatory
Exp Module 2 alarm map setting for Any Alarm.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.2 |
||||||
|
airFMSysAlarmMapExpMod2MaintReqmandatory
Exp Module 2 alarm map setting for Module Maintenance
Required. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.3 |
||||||
|
airFMSysAlarmMapExpMod2CoolFailmandatory
Exp Module 2 alarm map setting for Module Cooling
Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.4 |
||||||
|
Exp Module 2 alarm map setting for High Supply
Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.5 |
||||||
|
airFMSysAlarmMapExpMod2LowSupplyTempmandatory
Exp Module 2 alarm map setting for Low Supply
Temperature. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.6 |
||||||
|
airFMSysAlarmMapExpMod2HumFailmandatory
Exp Module 2 alarm map setting for Humidifier Failure.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.7 |
||||||
|
airFMSysAlarmMapExpMod2HumReplCylmandatory
Exp Module 2 alarm map setting for Humidifier Replace
Cylinder. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.8 |
||||||
|
airFMSysAlarmMapExpMod2CondPumpFailmandatory
Exp Module 2 alarm map setting for Condensate Pump
Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.9 |
||||||
|
airFMSysAlarmMapExpMod2BlwrCntl1Failmandatory
Exp Module 2 alarm map setting for Blower Controller 1
Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.10 |
||||||
|
airFMSysAlarmMapExpMod2BlwrCntl2Failmandatory
Exp Module 2 alarm map setting for Blower Controller 2
Failure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.11 |
||||||
|
airFMSysAlarmMapExpMod2HighFltrDPmandatory
Exp Module 2 alarm map setting for High Filter
Differential Pressure. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.12 |
||||||
|
airFMSysAlarmMapExpMod2LowAirFlowmandatory
Exp Module 2 alarm map setting for Low Air Flow.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.13 |
||||||
|
Exp Module 2 alarm map setting for Air Block Interlock
Open. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.14 |
||||||
|
airFMSysAlarmMapExpMod2WaterDetectedmandatory
Exp Module 2 alarm map setting for Water Detected.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.4.2.1.15 |
.1.3.6.1.4.1.318.1.1.13.1.4.12.5.2
·
1 row entry
·
17 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airFMSysAlarmMapInputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airFMSysAlarmMapInputTable'
Allows for getting alarm map information.
The input contact alarm map type to reference.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
airFMSysAlarmMapInputOutputIndexmandatory
The index of the output relay.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.1 |
||||||
|
airFMSysAlarmMapInput1mandatory
Input contact 1 alarm map setting.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.2 |
||||||
|
airFMSysAlarmMapInput2mandatory
Input contact 2 alarm map setting.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.3 |
||||||
|
airFMSysAlarmMapInput3mandatory
Input contact 3 alarm map setting.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.4 |
||||||
|
airFMSysAlarmMapInput4mandatory
Input contact 4 alarm map setting.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.5 |
||||||
|
airFMSysAlarmMapInput5mandatory
Input contact 5 alarm map setting.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.6 |
||||||
|
airFMSysAlarmMapInput6mandatory
Input contact 6 alarm map setting.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.7 |
||||||
|
airFMSysAlarmMapInput7mandatory
Input contact 7 alarm map setting.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.8 |
||||||
|
airFMSysAlarmMapInput8mandatory
Input contact 8 alarm map setting.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.9 |
||||||
|
airFMSysAlarmMapInput9mandatory
Input contact 9 alarm map setting.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.10 |
||||||
|
airFMSysAlarmMapInput10mandatory
Input contact 10 alarm map setting.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.11 |
||||||
|
airFMSysAlarmMapInput11mandatory
Input contact 11 alarm map setting.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.12 |
||||||
|
airFMSysAlarmMapInput12mandatory
Input contact 12 alarm map setting.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.13 |
||||||
|
airFMSysAlarmMapInput13mandatory
Input contact 13 alarm map setting.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.14 |
||||||
|
airFMSysAlarmMapInput14mandatory
Input contact 14 alarm map setting.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.15 |
||||||
|
airFMSysAlarmMapInput15mandatory
Input contact 15 alarm map setting.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.16 |
||||||
|
airFMSysAlarmMapInput16mandatory
Input contact 16 alarm map setting.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.5.2.1.17 |
.1.3.6.1.4.1.318.1.1.13.1.4.12.6.2
·
1 row entry
·
17 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airFMSysAlarmMapOutputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airFMSysAlarmMapOutputTable'
Allows for getting alarm map information.
The input contact alarm map type to reference.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
airFMSysAlarmMapOutputIndexmandatory
The index of the output relay.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.1 |
||||||
|
airFMSysAlarmMapOutput1mandatory
Output relay 1 alarm map setting.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.2 |
||||||
|
airFMSysAlarmMapOutput2mandatory
Output relay 2 alarm map setting.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.3 |
||||||
|
airFMSysAlarmMapOutput3mandatory
Output relay 3 alarm map setting.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.4 |
||||||
|
airFMSysAlarmMapOutput4mandatory
Output relay 4 alarm map setting.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.5 |
||||||
|
airFMSysAlarmMapOutput5mandatory
Output relay 5 alarm map setting.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.6 |
||||||
|
airFMSysAlarmMapOutput6mandatory
Output relay 6 alarm map setting.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.7 |
||||||
|
airFMSysAlarmMapOutput7mandatory
Output relay 7 alarm map setting.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.8 |
||||||
|
airFMSysAlarmMapOutput8mandatory
Output relay 8 alarm map setting.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.9 |
||||||
|
airFMSysAlarmMapOutput9mandatory
Output relay 9 alarm map setting.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.10 |
||||||
|
airFMSysAlarmMapOutput10mandatory
Output relay 10 alarm map setting.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.11 |
||||||
|
airFMSysAlarmMapOutput11mandatory
Output relay 11 alarm map setting.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.12 |
||||||
|
airFMSysAlarmMapOutput12mandatory
Output relay 12 alarm map setting.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.13 |
||||||
|
airFMSysAlarmMapOutput13mandatory
Output relay 13 alarm map setting.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.14 |
||||||
|
airFMSysAlarmMapOutput14mandatory
Output relay 14 alarm map setting.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.15 |
||||||
|
airFMSysAlarmMapOutput15mandatory
Output relay 15 alarm map setting.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.16 |
||||||
|
airFMSysAlarmMapOutput16mandatory
Output relay 16 alarm map setting.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.4.12.6.2.1.17 |
.1.3.6.1.4.1.318.1.1.13.1.5.1.2
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airFMModIdentTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airFMModIdentTable'
Allows for getting information from each module in the system.
The module to get information from.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
airFMModIdentModuleIndexmandatory
The index of the module.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.1.2.1.1 |
|
airFMModModelNumbermandatory
Model number of the Module.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.13.1.5.1.2.1.2 |
|
airFMModSerialNumbermandatory
Unique identification number for this Module.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.13.1.5.1.2.1.3 |
|
airFMModManufactureDatemandatory
Date the Module was manufactured.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.13.1.5.1.2.1.4 |
|
airFMModFirmwareRevmandatory
Revision number of the firmware installed on this
Module. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.13.1.5.1.2.1.5 |
|
airFMModHardwareRevmandatory
Revision number of the hardware installed on this
Module. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.13.1.5.1.2.1.6 |
.1.3.6.1.4.1.318.1.1.13.1.5.2.2
·
1 row entry
·
11 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airFMModStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airFMModStatusTable'
Allows for getting information from each module in the system.
The module to get information from.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
airFMModStatusModuleIndexmandatory
The index of the module.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.1 |
|
airFMModSupplyTempCmandatory
The temperature measured at the supply sensor.
Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.2 |
|
airFMModSupplyTempFmandatory
The temperature measured at the supply sensor.
Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.3 |
|
airFMModSupplyHummandatory
The humidity measured at the supply sensor.
Measured in tenths of percent relative humidity. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.4 |
|
airFMModReturnTempCmandatory
The temperature measured at the return sensor.
Measured in tenths of degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.5 |
|
airFMModReturnTempFmandatory
The temperature measured at the return sensor.
Measured in tenths of degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.6 |
|
airFMModReturnHummandatory
The humidity measured at the return sensor.
Measured in tenths of percent relative humidity. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.7 |
|
airFMModFilterDiffPresPamandatory
The difference in pressure on either side of the air
filters. A high differential pressure indicates a clogged filter. Measured in Pascals. A value of -2147483648 indicates that this OID does not apply to this device d… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.8 |
|
airFMModFilterDiffPresInWCmandatory
The difference in pressure on either side of the air
filters. A high differential pressure indicates a clogged filter. Measured in hundredths of inches water column. A value of -2147483648 indicates that this OID does … |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.9 |
|
airFMModCoilDiffPresPamandatory
The difference in pressure on either side of the
cooling/dehumidification coils. Measured in Pascals. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.10 |
|
airFMModCoilDiffPresInWCmandatory
The difference in pressure on either side of the
cooling/dehumidification coils. Measured in hundredths of inches water column. A value of -2147483648 indicates that this OID does not apply to this device due to its co… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.2.2.1.11 |
.1.3.6.1.4.1.318.1.1.13.1.5.3.2
·
1 row entry
·
13 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airFMModPropTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airFMModPropTable'
Allows for getting information from each module in the system.
The module to get information from.
Indexes
| Column | Syntax | OID | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
airFMModPropModuleIndexmandatory
The index of the module.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.1 |
||||||||||||||||
|
airFMModOutputCapacitymandatory
The cooling capacity (in Kilowatts) of the displayed
Module. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.2 |
||||||||||||||||
|
airFMModCapacityCtrlmandatory
The method used to load and unload the compressors.
Tandem compressor Modules use two stages (one compressor each). Single compressor Modules use hot gas bypass. A value of notApplicable indicates that this OID does not… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.3 |
||||||||||||||||
|
airFMModHeaterTypemandatory
The type of reheating device installed in this Module.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.4 |
||||||||||||||||
|
airFMModElectricHeaterTypemandatory
The type/capacity of the electric heater, if installed.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.5 |
||||||||||||||||
|
airFMModHumidifierTypemandatory
The type of equipment installed in the Module to run
the humidification mode. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.6 |
||||||||||||||||
|
airFMModBlwrFreqSettingmandatory
Frequency of the blower in tenths of hertz.
A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.7 |
||||||||||||||||
|
airFMModNomCoilDiffPresPamandatory
The difference in pressure on either side of the
cooling/dehumidification coils. Measured in Pascals. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.8 |
||||||||||||||||
|
airFMModNomCoilDiffPresInWCmandatory
The difference in pressure on either side of the
cooling/dehumidification coils. Measured in hundredths of inches water column. A value of -2147483648 indicates that this OID does not apply to this device due to its co… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.9 |
||||||||||||||||
|
airFMModCondPumpmandatory
Indicates the presence of a condensate pump in the
Modules of this System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.10 |
||||||||||||||||
|
airFMModFireDetectormandatory
Indicates the presence of a fire detector for each
of the Modules in this System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.11 |
||||||||||||||||
|
airFMModSmokeDetectormandatory
Indicates the presence of a smoke detector for each
of the Modules in this System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.12 |
||||||||||||||||
|
airFMModWaterDetectormandatory
Indicates the presence of a water leak detector for
each of the Modules in this System. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.13 |
.1.3.6.1.4.1.318.1.1.13.1.5.4.2
·
1 row entry
·
9 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airFMModCoolTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airFMModCoolTable'
Allows for getting information from each module in the system.
The module to get information from.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
airFMModCoolModuleIndexmandatory
The index of the module.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.1 |
||||||
|
airFMModComp1mandatory
The status of compressor 1 of the tandem compressor
unit (on or off). A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.2 |
||||||
|
airFMModComp2mandatory
The status of compressor 2 of the tandem compressor
unit (on or off). A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.3 |
||||||
|
airFMModSuctPresKPamandatory
The refrigerant pressure measured at the suction
inlet of the compressor. Measured in kiloPascals. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.4 |
||||||
|
airFMModSuctPresPSImandatory
The refrigerant pressure measured at the suction
inlet of the compressor. Measured in pounds per square inch. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.5 |
||||||
|
airFMModDischPresKPamandatory
The refrigerant pressure measured at the discharge
outlet of the compressor. Measured in kiloPascals. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.6 |
||||||
|
airFMModDischPresPSImandatory
The refrigerant pressure measured at the discharge
outlet of the compressor. Measured in pounds per square inch. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.7 |
||||||
|
airFMModCondFluidVlvPosmandatory
The position of the condenser fluid valve. The valve
regulates the flow of liquid coolant into the heat exchanger (condenser). 100% indicates the valve is completely open, and 0% indicates that the valve is closed. Mea… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.8 |
||||||
|
airFMModCoilFluidVlvPosmandatory
The position of the coil fluid valve. The valve
regulates the flow of liquid coolant in the fluid cooling coil (MultiCool, Economizer, or Chilled Water). 100% indicates the valve is completely open, and 0% indicates tha… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.4.2.1.9 |
.1.3.6.1.4.1.318.1.1.13.1.5.5.2
·
1 row entry
·
7 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airFMModHumTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airFMModHumTable'
Allows for getting information from each module in the system.
The module to get information from.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
airFMModHumModuleIndexmandatory
The index of the module.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.5.2.1.1 |
||||||||
|
airFMModHumidifiermandatory
The type of equipment installed in the Module to run
the humidification mode. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.5.5.2.1.2 |
||||||||
|
airFMModElectrodeCurrentmandatory
The current drawn by the electrodes of the steam
cylinder humidifier. Measured in tenths of amps. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.5.2.1.3 |
||||||||
|
airFMModHumActualOutputmandatory
The humidification output of an individual Module.
Measured in percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.5.2.1.4 |
||||||||
|
airFMModWaterConductivitymandatory
The conductivity of the water in the humidifier
cylinder. Measured in microSiemens per centimeter. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.5.2.1.5 |
||||||||
|
airFMModHotWaterVlvPosmandatory
The position of the hot water valve. 100% indicates
the valve is completely open, and 0% indicates that the valve is closed. Measured in percent. A value of -2147483648 indicates that this OID does not apply to this de… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.5.2.1.6 |
||||||||
|
airFMModStmElectHumModemandatory
Set the humidifier function mode.
Off: Remove power from electrodes. Auto: Humidifier controlled by Module controller. Drain: Remove power from electrodes and drain the cylinder. A value of notApplicable … |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.5.5.2.1.7 |
.1.3.6.1.4.1.318.1.1.13.1.5.6.2
·
1 row entry
·
25 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airFMModBlwr1Table
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airFMModBlwr1Table'
Allows for getting information from each module in the system.
The module to get information from.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
airFMModBlwr1ModuleIndexmandatory
The index of the module.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.1 |
||||||||
|
airFMModBlwr1CtrlTypemandatory
The type of blower controller.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.2 |
||||||||
|
airFMModBlwr1CmdFreqmandatory
The requested operating frequency for the blower.
Measured in tenths of hertz. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.3 |
||||||||
|
airFMModBlwr1ActFreqmandatory
The frequency at which the blower controller is
operating. Measured in tenths of hertz. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.4 |
||||||||
|
airFMModBlwr1Polesmandatory
The number of poles of the blower motor that the
blower controller is controlling. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.5 |
||||||||
|
airFMModBlwr1RatedHorsePowermandatory
The power rating of the blower motor. Measured in
hundredths of horsepower. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.6 |
||||||||
|
airFMModBlwr1RatedCurrentmandatory
The current rating of the blower motor. Measured in
hundredths of amps. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.7 |
||||||||
|
airFMModBlwr1ActTorqmandatory
The actual torque of the blower motor. Measured in
hundredths of percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.8 |
||||||||
|
airFMModBlwr1Currentmandatory
The percent of rated current drawn by the blower
motor. Measured in hundredths of percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.9 |
||||||||
|
airFMModBlwr1Vltmandatory
The voltage supplied to the blower motor. Measured
in tenths of volts RMS. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.10 |
||||||||
|
airFMModBlwr1DCLinkVltmandatory
The voltage of the blower controller's DC bus.
Measured in volts DC. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.11 |
||||||||
|
airFMModBlwr1AccTimemandatory
The time to accelerate the blower to the specified
frequency. Measured in tenths of seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.12 |
||||||||
|
airFMModBlwr1DecTimemandatory
The time to decelerate the blower frequency to zero.
Measured in tenths of seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.13 |
||||||||
|
airFMModBlwr1CapLifemandatory
The remaining life of the main circuit capacitor.
Measured in tenths of percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.14 |
||||||||
|
airFMModBlwr1CtrlCoolFanLifemandatory
The total operation time of the blower controller
cooling fan. Measured in hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.15 |
||||||||
|
airFMModBlwr1ElOvModemandatory
Enables or disables the electronic overload relay.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.16 |
||||||||
|
airFMModBlwr1ElOvSettingmandatory
The electronic overload relay is activated when the
current exceeds this threshold. Measured in hundredths of amps. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.17 |
||||||||
|
airFMModBlwr1ElOvTimeConstmandatory
The delay between the current exceeding the overload
threshold and the activation of the electronic overload relay. Measured in tenths of minutes. A value of -2147483648 indicates that this OID does not apply to this d… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.18 |
||||||||
|
airFMModBlwr1FanPowermandatory
The actual power of the blower motor. Measured in
tenths of percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.19 |
||||||||
|
airFMModBlwr1HeatsinkTempCmandatory
The temperature of the heatsink on the blower
controller. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.20 |
||||||||
|
airFMModBlwr1HeatsinkTempFmandatory
The temperature of the heatsink on the blower
controller. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.21 |
||||||||
|
airFMModBlwr1ChokeTempCmandatory
The temperature of the choke on the blower
controller. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.22 |
||||||||
|
airFMModBlwr1ChokeTempFmandatory
The temperature of the choke on the blower
controller. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.23 |
||||||||
|
airFMModBlwr1InverterTempCmandatory
The temperature of the inverter on the blower
controller. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.24 |
||||||||
|
airFMModBlwr1InverterTempFmandatory
The temperature of the inverter on the blower
controller. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.6.2.1.25 |
.1.3.6.1.4.1.318.1.1.13.1.5.7.2
·
1 row entry
·
25 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airFMModBlwr2Table
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airFMModBlwr2Table'
Allows for getting information from each module in the system.
The module to get information from.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
airFMModBlwr2ModuleIndexmandatory
The index of the module.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.1 |
||||||||
|
airFMModBlwr2CtrlTypemandatory
The type of blower controller.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.2 |
||||||||
|
airFMModBlwr2CmdFreqmandatory
The requested operating frequency for the blower.
Measured in tenths of hertz. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.3 |
||||||||
|
airFMModBlwr2ActFreqmandatory
The frequency at which the blower controller is
operating. Measured in tenths of hertz. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.4 |
||||||||
|
airFMModBlwr2Polesmandatory
The number of poles of the blower motor that the
blower controller is controlling. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.5 |
||||||||
|
airFMModBlwr2RatedHorsePowermandatory
The power rating of the blower motor. Measured in
hundredths of horsepower. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.6 |
||||||||
|
airFMModBlwr2RatedCurrentmandatory
The current rating of the blower motor. Measured in
hundredths of amps. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.7 |
||||||||
|
airFMModBlwr2ActTorqmandatory
The actual torque of the blower motor. Measured in
hundredths of percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.8 |
||||||||
|
airFMModBlwr2Currentmandatory
The percent of rated current drawn by the blower
motor. Measured in hundredths of percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.9 |
||||||||
|
airFMModBlwr2Vltmandatory
The voltage supplied to the blower motor. Measured
in tenths of volts RMS. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.10 |
||||||||
|
airFMModBlwr2DCLinkVltmandatory
The voltage of the blower controller's DC bus.
Measured in volts DC. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.11 |
||||||||
|
airFMModBlwr2AccTimemandatory
The time to accelerate the blower to the specified
frequency. Measured in tenths of seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.12 |
||||||||
|
airFMModBlwr2DecTimemandatory
The time to decelerate the blower frequency to zero.
Measured in tenths of seconds. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.13 |
||||||||
|
airFMModBlwr2CapLifemandatory
The remaining life of the main circuit capacitor.
Measured in tenths of percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.14 |
||||||||
|
airFMModBlwr2CtrlCoolFanLifemandatory
The total operation time of the blower controller
cooling fan. Measured in hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.15 |
||||||||
|
airFMModBlwr2ElOvModemandatory
Enables or disables the electronic overload relay.
A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.16 |
||||||||
|
airFMModBlwr2ElOvSettingmandatory
The electronic overload relay is activated when the
current exceeds this threshold. Measured in hundredths of amps. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.17 |
||||||||
|
airFMModBlwr2ElOvTimeConstmandatory
The delay between the current exceeding the overload
threshold and the activation of the electronic overload relay. Measured in tenths of minutes. A value of -2147483648 indicates that this OID does not apply to this d… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.18 |
||||||||
|
airFMModBlwr2FanPowermandatory
The actual power of the blower motor. Measured in
tenths of percent. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.19 |
||||||||
|
airFMModBlwr2HeatsinkTempCmandatory
The temperature of the heatsink on the blower
controller. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.20 |
||||||||
|
airFMModBlwr2HeatsinkTempFmandatory
The temperature of the heatsink on the blower
controller. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.21 |
||||||||
|
airFMModBlwr2ChokeTempCmandatory
The temperature of the choke on the blower
controller. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.22 |
||||||||
|
airFMModBlwr2ChokeTempFmandatory
The temperature of the choke on the blower
controller. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.23 |
||||||||
|
airFMModBlwr2InverterTempCmandatory
The temperature of the inverter on the blower
controller. Measured in degrees Celsius. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.24 |
||||||||
|
airFMModBlwr2InverterTempFmandatory
The temperature of the inverter on the blower
controller. Measured in degrees Fahrenheit. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.7.2.1.25 |
.1.3.6.1.4.1.318.1.1.13.1.5.8.2
·
1 row entry
·
15 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airFMModRHTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airFMModRHTable'
Allows for getting information from each module in the system.
The module to get information from.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
airFMModRHModuleIndexmandatory
The index of the module.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.1 |
||||||
|
airFMModRHComp1mandatory
Compressor 1 run hours.
A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.2 |
||||||
|
airFMModRHComp2mandatory
Compressor 2 run hours.
A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.3 |
||||||
|
airFMModRHHeatermandatory
Heater run hours.
A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.4 |
||||||
|
airFMModRHHummandatory
Humidifier run hours
A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.5 |
||||||
|
airFMModRHBlwr1mandatory
Blower 1 run hours.
A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.6 |
||||||
|
airFMModRHBlwr2mandatory
Blower 2 run hours.
A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.7 |
||||||
|
airFMModRHBlwrCtrl1mandatory
Blower Controller 1 run hours.
A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.8 |
||||||
|
airFMModRHBlwrCtrl2mandatory
Blower Controller 2 run hours.
A value of -2147483648 indicates that this OID does not apply to this device due to its configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.9 |
||||||
|
airFMModRHComp1Resetmandatory
Reset the compressor 1 run hours.
Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.10 |
||||||
|
airFMModRHComp2Resetmandatory
Reset the compressor 2 run hours.
Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.11 |
||||||
|
airFMModRHHeaterResetmandatory
Reset the heater run hours.
Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.12 |
||||||
|
airFMModRHHumResetmandatory
Reset the humidifier run hours.
Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.13 |
||||||
|
airFMModRHBlwr1Resetmandatory
Reset the blower 1 run hours.
Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.14 |
||||||
|
airFMModRHBlwr2Resetmandatory
Reset the blower 2 run hours.
Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configuration. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.5.8.2.1.15 |
.1.3.6.1.4.1.318.1.1.13.1.5.10.2
·
1 row entry
·
9 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airFMModServIntResetTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airFMModServIntResetTable'
Allows for getting information from each module in the system.
The module to get information from.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
airFMModServIntResetModuleIndexmandatory
The index of the module.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.1 |
||||||
|
airFMModServIntComp1Resetmandatory
Reset the compressor 1 service interval maintenance
alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its con… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.2 |
||||||
|
airFMModServIntComp2Resetmandatory
Reset the compressor 2 service interval maintenance
alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its con… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.3 |
||||||
|
airFMModServIntHeaterResetmandatory
Reset the heater service interval maintenance alarm.
Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configura… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.4 |
||||||
|
airFMModServIntHumResetmandatory
Reset the humidifier service interval maintenance
alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its confi… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.5 |
||||||
|
airFMModServIntBlwr1Resetmandatory
Reset the blower 1 service interval maintenance
alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configu… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.6 |
||||||
|
airFMModServIntBlwr2Resetmandatory
Reset the blower 2 service interval maintenance
alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to its configu… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.7 |
||||||
|
airFMModServIntBlwrCtrl1Resetmandatory
Reset the blower controller 1 service interval
maintenance alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to … |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.8 |
||||||
|
airFMModServIntBlwrCtrl2Resetmandatory
Reset the blower controller 2 service interval
maintenance alarm. Getting this OID will do nothing and return the noOperation value. A value of notApplicable indicates that this OID does not apply to this device due to … |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.9 |
.1.3.6.1.4.1.318.1.1.13.1.6.4
·
1 row entry
·
7 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airFMAlarmConditionsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airFMAlarmConditionsTable'
Table of active alarm conditions for the device.
Alarm condition specification
Indexes
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
airFMAlarmConditionsIndexmandatory
Alarm condition index.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.6.4.1.1 |
||||||||||
|
airFMAlarmSeveritymandatory
Severity of the alarm.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.6.4.1.2 |
||||||||||
|
airFMAlarmTypemandatory
Type of alarm.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.1.6.4.1.3 |
||||||||||
|
airFMEventCodemandatory
APC event code for the alarm.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.1.6.4.1.4 |
||||||||||
|
airFMAlarmDatemandatory
Date the alarm was recorded.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.13.1.6.4.1.5 |
||||||||||
|
airFMAlarmTimemandatory
Time the alarm was recorded.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.13.1.6.4.1.6 |
||||||||||
|
airFMAlarmDescriptionmandatory
Description of the alarm.
|
OctetString Constraints: range: 0-64 |
.1.3.6.1.4.1.318.1.1.13.1.6.4.1.7 |
.1.3.6.1.4.1.318.1.1.13.3.1.2
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airIRAlarmConditionsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airIRAlarmConditionsTable'
Table of active alarm conditions for the device.
Alarm condition specification
Indexes
| Column | Syntax | OID |
|---|---|---|
|
airIRAlarmConditionsIndexmandatory
Alarm condition index.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.3.1.2.1.1 |
|
airIREventCodemandatory
Code for the alarm.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.3.1.2.1.2 |
|
airIRAlarmDescriptionmandatory
Description of the alarm.
|
OctetString Constraints: range: 0-64 |
.1.3.6.1.4.1.318.1.1.13.3.1.2.1.3 |
.1.3.6.1.4.1.318.1.1.13.4.3.2
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airIRG2AlarmsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airIRG2AlarmsTable'
Table of active alarms for the device.
Alarms specification
Indexes
| Column | Syntax | OID |
|---|---|---|
|
airIRG2AlarmsIndexmandatory
Alarm index.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.4.3.2.1.1 |
|
airIRG2AlarmsEventCodemandatory
Code for the alarm.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.4.3.2.1.2 |
|
airIRG2AlarmsDescriptionmandatory
Description of the alarm.
|
OctetString Constraints: range: 0-64 |
.1.3.6.1.4.1.318.1.1.13.4.3.2.1.3 |
.1.3.6.1.4.1.318.1.1.13.4.5.2.2.5
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airIRG2RDT2RunHoursFanPSTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airIRG2RDT2RunHoursFanPSTable'
Allows for getting run hour information from each power supply.
The run hours fan power supply table entry.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
airIRG2RDT2RunHoursFanPSIndexmandatory
Index of run hours fan power supply table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.4.5.2.2.5.1.1 |
||||||||
|
airIRG2RDT2RunHoursFanPSHoursmandatory
Fan power supply run time in hours.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.4.5.2.2.5.1.2 |
||||||||
|
airIRG2RDT2RunHoursFanPSPositionmandatory
Position of fan power supply within the unit.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.4.5.2.2.5.1.3 |
.1.3.6.1.4.1.318.1.1.13.4.5.2.2.7
·
1 row entry
·
2 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airIRG2RDT2RunHoursEvapFanTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airIRG2RDT2RunHoursEvapFanTable'
Allows for getting information from each evaporator fan run hour in the system.
Allows for getting information from each evaporator fan run
hour in the system.
hour in the system.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
airIRG2RDT2RunHoursEvapFanIndexmandatory
Index of run hours evaporator fan table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.4.5.2.2.7.1.1 |
|
airIRG2RDT2RunHoursEvapFanHoursmandatory
Evaporator fan run time in hours.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.4.5.2.2.7.1.2 |
.1.3.6.1.4.1.318.1.1.13.5.2.2
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airIRmAlarmsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airIRmAlarmsTable'
Table of active alarms for the device.
Alarms specification
Indexes
| Column | Syntax | OID |
|---|---|---|
|
airIRmAlarmsIndexmandatory
Alarm index.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.5.2.2.1.1 |
|
airIRmAlarmsEventCodemandatory
Code for the alarm.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.5.2.2.1.2 |
|
airIRmAlarmsDescriptionmandatory
Description of the alarm.
|
OctetString Constraints: range: 0-64 |
.1.3.6.1.4.1.318.1.1.13.5.2.2.1.3 |
.1.3.6.1.4.1.318.1.1.13.6.1.2
·
1 row entry
·
11 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airIRG3IdentTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airIRG3IdentTable'
Allows to get ident information of current RDU and its assigned CM's.
The ident table entry.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
airIRG3IdentIndexmandatory
Index of ident table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.1.2.1.1 |
|
airIRG3IdentNamemandatory
A character string identifying the unit name.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.13.6.1.2.1.2 |
|
airIRG3IdentLocationmandatory
A character string identifying the unit location.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.13.6.1.2.1.3 |
|
airIRG3IdentModelNumbermandatory
A character string identifying the unit model number.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.13.6.1.2.1.4 |
|
airIRG3IdentSerialNumbermandatory
A character string identifying the unit serial number.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.13.6.1.2.1.5 |
|
airIRG3IdentFirmwareRevisionmandatory
A character string identifying the unit firmware version.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.13.6.1.2.1.6 |
|
airIRG3IdentHardwareRevisionmandatory
A character string identifying the unit controller hardware revision.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.13.6.1.2.1.7 |
|
airIRG3IdentManufactureDatemandatory
A character string identifying the unit manufacture date.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.13.6.1.2.1.8 |
|
airIRG3IdentRDUSysOIDmandatory
This OID contains an OID path to the RDU data.
|
ObjectIdentifier | .1.3.6.1.4.1.318.1.1.13.6.1.2.1.9 |
|
airIRG3IdentCMSysOIDmandatory
This OID contains an OID path to the cooling module data.
|
ObjectIdentifier | .1.3.6.1.4.1.318.1.1.13.6.1.2.1.10 |
|
airIRG3IdentGroupSysOIDmandatory
This OID contains an OID path to the group data.
|
ObjectIdentifier | .1.3.6.1.4.1.318.1.1.13.6.1.2.1.11 |
.1.3.6.1.4.1.318.1.1.13.6.2.2
·
1 row entry
·
22 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airIRG3GroupStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airIRG3GroupStatusTable'
Allows to get group status information.
The group staus table entry.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
airIRG3GroupStatusIndexmandatory
Index of group status table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.2.2.1.1 |
|
airIRG3GroupStatusCoolOutputmandatory
The group cooling output in tenths of kilowatts (kW).
Returns (-1) if not supported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.2.2.1.2 |
|
airIRG3GroupStatusCoolDemandmandatory
The group cooling demand in tenths of kilowatts (kW).
Returns (-1) if not supported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.2.2.1.3 |
|
airIRG3GroupStatusAirFlowUSmandatory
The group air flow in cubic feet per minute (CFM).
Returns (-1) if not supported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.2.2.1.4 |
|
airIRG3GroupStatusAirFlowMetricmandatory
The group air flow in liters per second (L/s).
Returns (-1) if not supported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.2.2.1.5 |
|
airIRG3GroupStatusMaxRackInletTempUSmandatory
The group maximum rack inlet temperature in tenths of
degrees Fahrenheit. Returns (-1) if not supported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.2.2.1.6 |
|
The group maximum rack inlet temperature in tenths of
degrees Celsius. Returns (-1) if not supported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.2.2.1.7 |
|
airIRG3GroupStatusMinRackInletTempUSmandatory
The group minimum rack inlet temperature in tenths of
degrees Fahrenheit. Returns (-1) if not supported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.2.2.1.8 |
|
The group minimum rack inlet temperature in tenths of
degrees Celsius. Returns (-1) if not supported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.2.2.1.9 |
|
airIRG3GroupStatusMaxReturnAirTempUSmandatory
The group maximum return air temperature in tenths of
degrees Fahrenheit. Returns (-1) if not supported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.2.2.1.10 |
|
The group maximum return air temperature in tenths of
degrees Celsius. Returns (-1) if not supported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.2.2.1.11 |
|
airIRG3GroupStatusMinReturnAirTempUSmandatory
The group minimum return air temperature in tenths of
degrees Fahrenheit. Returns (-1) if not supported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.2.2.1.12 |
|
The group minimum return air temperature in tenths of
degrees Celsius. Returns (-1) if not supported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.2.2.1.13 |
|
airIRG3GroupStatusAvgSupplyTempUSmandatory
The group average supply air temperature in tenths of
degrees Fahrenheit. Returns (-1) if not supported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.2.2.1.14 |
|
The group average supply air temperature in tenths of
degrees Celsius. Returns (-1) if not supported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.2.2.1.15 |
|
airIRG3GroupStatusAvgReturnTempUSmandatory
The group average return air temperature in tenths of
degrees Fahrenheit. Returns (-1) if not supported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.2.2.1.16 |
|
The group average return air temperature in tenths of
degrees Celsius. Returns (-1) if not supported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.2.2.1.17 |
|
airIRG3GroupStatusAvgFanSpeedmandatory
The group average fan speed in revolutions per minute (RPM).
Returns (-1) if not supported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.2.2.1.18 |
|
airIRG3GroupStatusAvgAirFlowUSmandatory
The group average air flow in cubic feet per minute (CFM).
Returns (-1) if not supported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.2.2.1.19 |
|
airIRG3GroupStatusAvgAirFlowMetricmandatory
The group average air flow in liters per second (L/s).
Returns (-1) if not supported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.2.2.1.20 |
|
airIRG3GroupStatusTotalAirFlowUSmandatory
The group total air flow in cubic feet per minute (CFM).
Returns (-1) if not supported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.2.2.1.21 |
|
airIRG3GroupStatusTotalAirFlowMetricmandatory
The group total air flow in liters per second (L/s).
Returns (-1) if not supported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.2.2.1.22 |
.1.3.6.1.4.1.318.1.1.13.6.2.3
·
1 row entry
·
10 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airIRG3GroupSetpointsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airIRG3GroupSetpointsTable'
Allows to access the group setpoints.
The group setpoints table entry.
Indexes
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
airIRG3GroupSetpointsIndexmandatory
Index of group setpoints table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.2.3.1.1 |
||||||||||
|
airIRG3GroupSetpointsCoolSetpointUSmandatory
Group cooling setpoint in tenths of
degrees Fahrenheit. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.2.3.1.2 |
||||||||||
|
Group cooling setpoint in tenths of
degrees Celsius. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.2.3.1.3 |
||||||||||
|
airIRG3GroupSetpointsCoolDeadbandUSmandatory
Group cooling deadband in tenths of
degrees Fahrenheit. Returns (-1) if not supported. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.2.3.1.4 |
||||||||||
|
Group cooling deadband in tenths of
degrees Celsius. Returns (-1) if not supported. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.2.3.1.5 |
||||||||||
|
The group preferred fan speed setting.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.6.2.3.1.6 |
||||||||||
|
Group supply air setpoint in tenths of
degrees Fahrenheit. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.2.3.1.7 |
||||||||||
|
Group supply air setpoint in tenths of
degrees Celsius. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.2.3.1.8 |
||||||||||
|
airIRG3GroupSetpointsAirFlowControlmandatory
The group air flow control.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.6.2.3.1.9 |
||||||||||
|
airIRG3GroupSetpointsLightingOnTimemandatory
The group lighting on time in minutes.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.2.3.1.10 |
.1.3.6.1.4.1.318.1.1.13.6.2.4
·
1 row entry
·
12 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airIRG3GroupConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airIRG3GroupConfigTable'
Allows to access group configuration table.
The group config table entry.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
airIRG3GroupConfigIndexmandatory
Index of group config table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.2.4.1.1 |
||||||||
|
The number of cooling units.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.2.4.1.2 |
||||||||
|
airIRG3GroupConfigConfigurationTypemandatory
The group configuration type.
The spot configuration type is not supported. Returns (-1) if not supported. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.6.2.4.1.3 |
||||||||
|
The group capacity control. Returns (-1) if not supported.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.6.2.4.1.4 |
||||||||
|
airIRG3GroupConfigFanSpeedControlmandatory
The group fan speed control.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.6.2.4.1.5 |
||||||||
|
airIRG3GroupConfigCoolGainPmandatory
The gain component of the PID in hundredths.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.2.4.1.6 |
||||||||
|
airIRG3GroupConfigCoolResetRateImandatory
The integral component of the PID in hundredths.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.2.4.1.7 |
||||||||
|
airIRG3GroupConfigCoolDerivativeDmandatory
The derivative component of the PID in hundredths.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.2.4.1.8 |
||||||||
|
airIRG3GroupConfigCoolPIDResetmandatory
Will reset the PID coefficients back to the factory defaults.
Readback is not supported, returns -1. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.6.2.4.1.9 |
||||||||
|
The number of backup units.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.2.4.1.10 |
||||||||
|
Enable or disable runtime balancing feature.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.6.2.4.1.11 |
||||||||
|
airIRG3GroupConfigLoadAssistEnablemandatory
Enable or disable load assist feature.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.6.2.4.1.12 |
.1.3.6.1.4.1.318.1.1.13.6.3.2
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airIRG3AlarmsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airIRG3AlarmsTable'
Table of active alarms for the device.
Alarms specification
Indexes
| Column | Syntax | OID |
|---|---|---|
|
airIRG3AlarmsIndexmandatory
Alarm index.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.3.2.1.1 |
|
airIRG3AlarmsEventCodemandatory
Event Code for the alarm. Returns (-1) if not supported.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.3.2.1.2 |
|
airIRG3AlarmsDescriptionmandatory
Description of the alarm. Returns (-1) if not supported.
|
OctetString Constraints: range: 0-64 |
.1.3.6.1.4.1.318.1.1.13.6.3.2.1.3 |
.1.3.6.1.4.1.318.1.1.13.6.4.2
·
1 row entry
·
43 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airIRG3RDUStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airIRG3RDUStatusTable'
Allows to access RDU status table.
The RDU status table entry.
Indexes
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
airIRG3RDUStatusDeviceIndexmandatory
Index of RDU status table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.1 |
||||||||||
|
airIRG3RDUIDmandatory
The current RDU ID (1 to F).
Configured RDU only shall display ID, else return -1. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.2 |
||||||||||
|
airIRG3RDUStatusOnReadyStandbymandatory
The RDU current status.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.3 |
||||||||||
|
airIRG3RDUStatusOperatingModemandatory
The RDU actual operating mode.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.4 |
||||||||||
|
airIRG3RDUStatusLeadPumpmandatory
The RDU lead pump.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.5 |
||||||||||
|
airIRG3RDUStatusStartupDelaymandatory
The RDU start up delay in seconds.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.6 |
||||||||||
|
The RDU pump change over interval in days.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.7 |
||||||||||
|
airIRG3RDUStatusStopOnLeakDetectmandatory
The RDU status of stop on leak detect.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.8 |
||||||||||
|
airIRG3RDUStatusPowerSourcemandatory
The RDU power source status.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.9 |
||||||||||
|
airIRG3RDUStatusTotalRDUOutputPowermandatory
The RDU output power in tenths of kilowatts (kW).
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.10 |
||||||||||
|
airIRG3RDUStatusInletWaterTempUSmandatory
The RDU inlet water temperature in tenths of
degrees Fahrenheit. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.11 |
||||||||||
|
airIRG3RDUStatusInletWaterTempMetricmandatory
The RDU inlet water temperature in tenths of
degrees Celsius. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.12 |
||||||||||
|
airIRG3RDUStatusOutletWaterTempUSmandatory
The RDU outlet water temperature in tenths of
degrees Fahrenheit. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.13 |
||||||||||
|
The RDU outlet water temperature in tenths of
degrees Celsius. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.14 |
||||||||||
|
The RDU condenser saturation temperature in tenths of
degrees Fahrenheit. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.15 |
||||||||||
|
The RDU condenser saturation temperature in tenths of
degrees Celsius. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.16 |
||||||||||
|
airIRG3RDUStatusDewPointTempUSmandatory
The RDU dew point temperature in tenths of
degrees Fahrenheit. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.17 |
||||||||||
|
airIRG3RDUStatusDewPointTempMetricmandatory
The RDU dew point temperature in tenths of
degrees Celsius. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.18 |
||||||||||
|
airIRG3RDUStatusPumpOutletTempUSmandatory
The RDU pump outlet temperature in tenths of
degrees Fahrenheit. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.19 |
||||||||||
|
airIRG3RDUStatusPumpOutletTempMetricmandatory
The RDU pump outlet temperature in tenths of
degrees Celsius. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.20 |
||||||||||
|
The RDU sub cooler outlet temperature in tenths of
degrees Fahrenheit. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.21 |
||||||||||
|
The RDU sub cooler outlet temperature in tenths of
degrees Celsius. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.22 |
||||||||||
|
The RDU condenser outlet temperature in tenths of
degrees Fahrenheit. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.23 |
||||||||||
|
The RDU condenser outlet temperature in tenths of
degrees Celsius. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.24 |
||||||||||
|
airIRG3RDUStatusCondenserInletTempUSmandatory
The RDU condenser inlet temperature in tenths of
degrees Fahrenheit. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.25 |
||||||||||
|
The RDU condenser inlet temperature in tenths of
degrees Celsius. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.26 |
||||||||||
|
The RDU condenser outlet pressure in
pounds per square inch (PSI). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.27 |
||||||||||
|
The RDU condenser outlet pressure in kiloPascals (KPa).
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.28 |
||||||||||
|
airIRG3RDUStatusPump1HeadPressureUSmandatory
The RDU Pump 1 head pressure in pounds per square inch (PSI).
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.29 |
||||||||||
|
The RDU Pump 1 head pressure in kiloPascals (KPa).
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.30 |
||||||||||
|
airIRG3RDUStatusPump2HeadPressureUSmandatory
The RDU Pump 2 head pressure in pounds per square inch (PSI).
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.31 |
||||||||||
|
The RDU Pump 2 head pressure in kiloPascals (KPa).
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.32 |
||||||||||
|
airIRG3RDUStatusPump1Speedmandatory
The RDU Pump 1 speed in revolutions per minute (RPM).
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.33 |
||||||||||
|
airIRG3RDUStatusPump2Speedmandatory
The RDU Pump 2 speed in revolutions per minute (RPM).
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.34 |
||||||||||
|
airIRG3RDUStatusCWValvePositionmandatory
The RDU CW Valve position in % open
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.35 |
||||||||||
|
airIRG3RDUStatusReceiverLiquidLevelmandatory
The RDU receiver liquid level in % Full
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.36 |
||||||||||
|
The RDU DC Power Supply 1 Current in Amps
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.37 |
||||||||||
|
The RDU DC Power Supply 2 Current in Amps
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.38 |
||||||||||
|
The RDU Total DC Power Supply Current in Amps
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.39 |
||||||||||
|
airIRG3RDUStatusInputStatemandatory
The RDU Input state.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.40 |
||||||||||
|
airIRG3RDUStatusOutputStatemandatory
The RDU Output state
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.41 |
||||||||||
|
airIRG3RDUStatusByPassValvePositionmandatory
The RDU By Pass Valve position in % open
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.42 |
||||||||||
|
The RDU refrigerant leak detector status.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.43 |
.1.3.6.1.4.1.318.1.1.13.6.4.3
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airIRG3RDURunHoursTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airIRG3RDURunHoursTable'
Allows to access RDU run hours table.
The RDU run hours table entry.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
airIRG3RDURunHoursDeviceIndexmandatory
Index of RDU run hours table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.3.1.1 |
|
airIRG3RDURunHoursRDUIDmandatory
The current RDU ID (1 to F).
Configured RDU only shall display ID, else return -1. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.13.6.4.3.1.2 |
|
airIRG3RDURunHoursPump1mandatory
The RDU run hours of Pump 1.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.3.1.3 |
|
airIRG3RDURunHoursPump2mandatory
The RDU run hours of Pump 2.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.3.1.4 |
|
airIRG3RDURunHoursPowerSupply1mandatory
The RDU run hours of power supply 1.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.3.1.5 |
|
airIRG3RDURunHoursPowerSupply2mandatory
The RDU run hours of power supply 2.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.3.1.6 |
.1.3.6.1.4.1.318.1.1.13.6.4.4
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airIRG3RDUServiceIntervalsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airIRG3RDUServiceIntervalsTable'
Allows to access RDU service intervals table.
The service interval table entry.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
Index of service interval table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.4.1.1 |
||||
|
airIRG3RDUServiceIntervalsRDUIDmandatory
The current RDU ID (1 to F).
Configured RDU only shall display ID, else return -1. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.13.6.4.4.1.2 |
||||
|
The RDU service interval for air filter in hours.
Returns -1 if not supported. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.4.1.3 |
||||
|
The RDU service interval air filter alarm status.
Returns -1 if not supported. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.6.4.4.1.4 |
.1.3.6.1.4.1.318.1.1.13.6.4.5
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airIRG3RDUThresholdsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airIRG3RDUThresholdsTable'
Allows to access RDU thresholds table.
The RDU thresholds table entry.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
airIRG3RDUThresholdsDeviceIndexmandatory
Index of RDU thresholds table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.5.1.1 |
|
airIRG3RDUThresholdsRDUIDmandatory
The current RDU ID (1 to F).
Configured RDU only shall display ID, else return -1. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.13.6.4.5.1.2 |
|
The RDU threshold for entering fluid temperature in tenths of
degrees Fahrenheit. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.5.1.3 |
|
The RDU threshold for entering fluid temperature in tenths of
degrees Celsius. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.5.1.4 |
.1.3.6.1.4.1.318.1.1.13.6.4.6
·
1 row entry
·
1 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airIRG3RDUSetpointsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airIRG3RDUSetpointsTable'
Allows to access RDU set points table.
The RDU set points table entry.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
airIRG3RDUSetpointsDeviceIndexmandatory
Index of RDU set points table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.6.1.1 |
.1.3.6.1.4.1.318.1.1.13.6.4.7
·
1 row entry
·
13 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airIRG3RDUConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airIRG3RDUConfigTable'
Allows to access RDU configuration table.
The RDU configuration table entry.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
airIRG3RDUConfigDeviceIndexmandatory
Index of RDU configuration table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.7.1.1 |
||||||
|
airIRG3RDUConfigRDUIDmandatory
The current RDU ID (1 to F).
Configured RDU only shall display ID, else return -1. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.13.6.4.7.1.2 |
||||||
|
airIRG3RDUConfigStopOnLeakDetectmandatory
The RDU stop on leak detect set.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.6.4.7.1.3 |
||||||
|
airIRG3RDUConfigStartupDelaymandatory
The RDU start up delay in seconds.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.7.1.4 |
||||||
|
The RDU pump change over interval in days.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.4.7.1.5 |
||||||
|
airIRG3RDUConfigPowerSourcemandatory
The RDU power source.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.6.4.7.1.6 |
||||||
|
airIRG3RDUConfigOutputSourcemandatory
The RDU output source.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.6.4.7.1.7 |
||||||
|
airIRG3RDUConfigInputNormalStatemandatory
The RDU Input Normal State.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.6.4.7.1.8 |
||||||
|
airIRG3RDUConfigOutputNormalStatemandatory
The RDU Output Normal State.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.6.4.7.1.9 |
||||||
|
airIRG3RDUConfigByPassValveEnabledmandatory
The RDU By Pass Valve Enabled State.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.6.4.7.1.10 |
||||||
|
The RDU Refrigerant Leak Detector Enabled State.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.6.4.7.1.11 |
||||||
|
This parameter allows to calibrate the RDU Refrigerant Leak Detector and is write only.
The read returns -1. Only 'yes' is supported. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.6.4.7.1.12 |
||||||
|
airIRG3RDUConfigOnReadyStandbymandatory
This parameter allows to configure RDU on/standby parameter.
Ready is currently not supported. If unsupported returns -1. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.6.4.7.1.13 |
.1.3.6.1.4.1.318.1.1.13.6.5.2
·
1 row entry
·
22 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airIRG3CMStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airIRG3CMStatusTable'
Allows to access CM status table.
The CM status table entry.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
airIRG3CMStatusDeviceIndexmandatory
Index of CM status table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.5.2.1.1 |
||||||
|
airIRG3CMStatusCMIDmandatory
The CM ID (RDU Number - Group Number - CM Unit Number).
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.13.6.5.2.1.2 |
||||||
|
airIRG3CMStatusOperatingModemandatory
The current operating mode of the CM.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.6.5.2.1.3 |
||||||
|
airIRG3CMStatusUnitTypemandatory
The current CM unit type.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.6.5.2.1.4 |
||||||
|
airIRG3CMStatusRackInletTempUSmandatory
The CM rack inlet temperature in tenths of
degrees Fahrenheit. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.5.2.1.5 |
||||||
|
airIRG3CMStatusRackInletTempMetricmandatory
The CM rack inlet temperature in tenths of
degrees Celsius. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.5.2.1.6 |
||||||
|
airIRG3CMStatusReturnAirTempUSmandatory
The CM return air temperature in tenths of
degrees Fahrenheit. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.5.2.1.7 |
||||||
|
airIRG3CMStatusReturnAirTempMetricmandatory
The CM return air temperature in tenths of
degrees Celsius. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.5.2.1.8 |
||||||
|
airIRG3CMStatusLiquidTempUSmandatory
The CM liquid temperature in tenths of
degrees Fahrenheit. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.5.2.1.9 |
||||||
|
airIRG3CMStatusLiquidTempMetricmandatory
The CM liquid temperature in tenths of
degrees Celsius. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.5.2.1.10 |
||||||
|
airIRG3CMStatusVaporTempUSmandatory
The CM vapor temperature in tenths of
degrees Fahrenheit. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.5.2.1.11 |
||||||
|
airIRG3CMStatusVaporTempMetricmandatory
The CM vapor temperature in tenths of
degrees Celsius. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.5.2.1.12 |
||||||
|
airIRG3CMStatusEvaporatorTempUSmandatory
The CM saturation temperature in tenths of
degrees Fahrenheit. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.5.2.1.13 |
||||||
|
airIRG3CMStatusEvaporatorTempMetricmandatory
The CM saturation temperature in tenths of
degrees Celsius. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.5.2.1.14 |
||||||
|
airIRG3CMStatusLiquidInletPressureUSmandatory
The CM Liquid Inlet pressure in pounds per square inch (PSI).
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.5.2.1.15 |
||||||
|
The CM Liquid Inlet pressure in kiloPascals (kPa).
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.5.2.1.16 |
||||||
|
airIRG3CMStatusVaporOutletPressureUSmandatory
The CM Vapor Outlet pressure in pounds per square inch (PSI).
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.5.2.1.17 |
||||||
|
The CM Vapor Outlet pressure in kiloPascals (kPa).
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.5.2.1.18 |
||||||
|
The CM expansion valve position in % open
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.5.2.1.19 |
||||||
|
airIRG3CMStatusEPRValvePositionmandatory
The CM Evaporator Pressure Regulator Valve Position
in tenths of percent open |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.5.2.1.20 |
||||||
|
The status of the on/off control on the CM local display.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.6.5.2.1.21 |
||||||
|
airIRG3CMStatusAverageFanSpeedmandatory
The CM Average Fan Speed.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.5.2.1.22 |
.1.3.6.1.4.1.318.1.1.13.6.5.3
·
1 row entry
·
8 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airIRG3CMRunHoursTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airIRG3CMRunHoursTable'
Allows to access CM run hours table.
The CM run hours table entry.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
airIRG3CMRunHoursDeviceIndexmandatory
Index of CM run hours table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.5.3.1.1 |
|
airIRG3CMRunHoursCMIDmandatory
The CM ID (RDU Number - Group Number - CM Unit Number).
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.13.6.5.3.1.2 |
|
airIRG3CMRunHoursFan1mandatory
The CM run hours for Fan1.
Returns (-1) if not appilcable. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.5.3.1.3 |
|
airIRG3CMRunHoursFan2mandatory
The CM run hours for Fan2.
Returns (-1) if not appilcable. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.5.3.1.4 |
|
airIRG3CMRunHoursFan3mandatory
The CM run hours for Fan3.
Returns (-1) if not appilcable. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.5.3.1.5 |
|
airIRG3CMRunHoursFan4mandatory
The CM run hours for Fan4.
Returns (-1) if not appilcable. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.5.3.1.6 |
|
airIRG3CMRunHoursFan5mandatory
The CM run hours for Fan5.
Returns (-1) if not appilcable. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.5.3.1.7 |
|
airIRG3CMRunHoursAirFiltermandatory
The CM run hours for air filter.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.5.3.1.8 |
.1.3.6.1.4.1.318.1.1.13.6.5.4
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airIRG3CMServiceIntervalsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airIRG3CMServiceIntervalsTable'
Allows to access CM service intervals table.
The CM service interval table entry.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
airIRG3CMServiceIntervalsDeviceIndexmandatory
Index of CM service intervals table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.5.4.1.1 |
||||
|
airIRG3CMServiceIntervalsCMIDmandatory
The CM ID (RDU Number - Group Number - CM Unit Number).
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.13.6.5.4.1.2 |
||||
|
The CM service interval for air filter in weeks.
Supported only for RA. Returns -1 if not supported. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.5.4.1.3 |
||||
|
The CM service interval air filter alarm status.
Supported only for RA. Returns -1 if not supported. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.6.5.4.1.4 |
.1.3.6.1.4.1.318.1.1.13.6.5.5
·
1 row entry
·
8 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airIRG3CMThresholdsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airIRG3CMThresholdsTable'
Allows to access CM thresholds table.
The CM thresholds table entry.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
airIRG3CMThresholdsDeviceIndexmandatory
Index for CM thresholds table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.5.5.1.1 |
|
airIRG3CMThresholdsCMIDmandatory
The CM ID (RDU Number - Group Number - CM Unit Number).
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.13.6.5.5.1.2 |
|
The CM high threshold for rack inlet temperature in tenths of
degrees Fahrenheit. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.5.5.1.3 |
|
The CM high threshold for rack inlet temperature in tenths of
degrees Celsius. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.5.5.1.4 |
|
The CM high threshold for supply air temperature in tenths of
degrees Fahrenheit. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.5.5.1.5 |
|
The CM high threshold for supply air temperature in tenths of
degrees Celsius. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.5.5.1.6 |
|
The CM high threshold for return air temperature in tenths of
degrees Fahrenheit. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.5.5.1.7 |
|
The CM high threshold for return air temperature in tenths of
degrees Celsius. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.5.5.1.8 |
.1.3.6.1.4.1.318.1.1.13.6.5.6
·
1 row entry
·
1 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airIRG3CMSetpointsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airIRG3CMSetpointsTable'
Allows to access CM set points table.
The CM set points table entry.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
airIRG3CMSetpointsDeviceIndexmandatory
Index of CM set points table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.5.6.1.1 |
.1.3.6.1.4.1.318.1.1.13.6.5.7
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk airIRG3CMConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::airIRG3CMConfigTable'
Allows to access CM configuration table.
The CM configuration table entry.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
airIRG3CMConfigDeviceIndexmandatory
Index of CM configuration table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.5.7.1.1 |
||||
|
airIRG3CMConfigCMIDmandatory
The CM ID (RDU Number - Group Number - CM Unit Number).
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.13.6.5.7.1.2 |
||||
|
airIRG3CMConfigStopOnCoolFailmandatory
Enable/Disable Stop On cool fail. When enabled, stops the unit
if it detects that it is blowing warm air into the cold aisle. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.6.5.7.1.3 |
||||
|
airIRG3CMConfigStartupDelaymandatory
The CM start up delay in seconds.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.13.6.5.7.1.4 |
||||
|
airIRG3CMConfigRemoteOnStandbymandatory
The CM configuration for operating mode.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.6.5.7.1.5 |
||||
|
airIRG3CMConfigPowerSourcemandatory
The CM power source.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.13.6.5.7.1.6 |
.1.3.6.1.4.1.318.1.1.14.1.1
·
1 row entry
·
2 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rARUIdentTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rARUIdentTable'
Allows for query of the individual devices. The number of entries is contained in the rARUStatusAruDeviceCount OID.
The device to query.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
rARUIdentAruIndexmandatory
The index to the ARU entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.14.1.1.1.1 |
|
rARUIdentNamemandatory
A character string identifying the device.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.14.1.1.1.2 |
.1.3.6.1.4.1.318.1.1.14.2.1
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rARUConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rARUConfigTable'
Allows for configuration of the individual ARU devices accessible from this IP address. The number of entries is contained in the rARUStatusAruDeviceCount OID.
The ARUs to configure.
Indexes
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
rARUConfigAruIndexmandatory
The index to the ARU entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.14.2.1.1.1 |
||||||||||||||||||||||||||||||||||||
|
rARUConfigAruNamemandatory
The name of the ARU.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.14.2.1.1.2 |
||||||||||||||||||||||||||||||||||||
|
rARUConfigAruRemoteSetpointmandatory
This OID defines the desired base airflow of the ARU, and sets the
speed of the ARU fans when the temperature override is inactive. Values specified in cfm (cubic feet per minute) can be converted to metr… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.14.2.1.1.3 |
||||||||||||||||||||||||||||||||||||
|
rARUConfigAruTempOvrdEnableDisablemandatory
This OID is used to enable/disable the remote temperature override setting of the ARU.
If this OID is set to 1, the remote setting for temperature override is disabled. If this OID is set to 2, the remote… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.14.2.1.1.4 |
||||||||||||||||||||||||||||||||||||
|
rARUConfigAruTempOvrdSetpointmandatory
This OID is the Temperature Override setpoint of the ARU.
NOTE: -1 will be returned if the ARU is not communicating. Values are represented in whole number degrees using the units specified… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.14.2.1.1.5 |
||||||||||||||||||||||||||||||||||||
|
rARUConfigAruMasterControlmandatory
This is the master on/off control for the ARU.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.14.2.1.1.6 |
.1.3.6.1.4.1.318.1.1.14.3.3
·
1 row entry
·
14 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rARUStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rARUStatusTable'
Allows for query of the individual ARUs accessible from this IP address. The number of entries is contained in the rARUStatusAruDeviceCount OID.
The ARUs to access.
Indexes
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
rARUStatusAruIndexmandatory
The index to the ARU entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.14.3.3.1.1 |
||||||||||||||||||||||||||||||||||||
|
rARUStatusAruNamemandatory
The name of the ARU.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.14.3.3.1.2 |
||||||||||||||||||||||||||||||||||||
|
rARUStatusAruRemoteSetpointmandatory
This OID defines the desired base airflow of the ARU, or the
speed of the ARU fans when the temperature override is inactive. See also the rARUConfigAruRemoteSetpoint OID. NOTE: -1 will be … |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.14.3.3.1.3 |
||||||||||||||||||||||||||||||||||||
|
rARUStatusAruManualSetpointmandatory
Manual operating setpoint of the ARU, which is set on the
panel of the ARU. If the ARU doesn't have a manual , the OID will always return a value of aruRem (10). NOTE: -1 will be returned if the ARU is no… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.14.3.3.1.4 |
||||||||||||||||||||||||||||||||||||
|
rARUStatusAruTemp1mandatory
ARU temperature probe #1 reading.
The summary exhaust temperature on 2nd generation ARUs. NOTE: -1 will be returned if the ARU is not communicating. Values are represented in whole number d… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.14.3.3.1.5 |
||||||||||||||||||||||||||||||||||||
|
rARUStatusAruTemp2mandatory
ARU temperature probe #2 reading.
The exhaust temperature in the upper plenum on 2nd generation ARUs. NOTE: -1 will be returned if the ARU is not communicating. Values are represented in wh… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.14.3.3.1.6 |
||||||||||||||||||||||||||||||||||||
|
rARUStatusAruTemp3mandatory
ARU temperature probe #3 reading.
The exhaust temperature in the lower plenum on 2nd generation ARUs. NOTE: -1 will be returned if the ARU is not communicating. Values are represented in wh… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.14.3.3.1.7 |
||||||||||||||||||||||||||||||||||||
|
rARUStatusAruTempOvrdEnableDisablemandatory
This OID indicates whether the ARU remote temperature override is enabled or disabled.
If this OID is a 1, the remote setting for temperature override is disabled. If this OID is a 2, the remote setting for temperature … |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.14.3.3.1.8 |
||||||||||||||||||||||||||||||||||||
|
rARUStatusAruTempOvrdSetpointmandatory
ARU remote temperature override setpoint setting.
NOTE: -1 will be returned if the ARU is not communicating. Values are represented in whole number degrees. Units are displayed in the scale… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.14.3.3.1.9 |
||||||||||||||||||||||||||||||||||||
|
rARUStatusAruAlarmStatemandatory
An ASCII string containing the 8 flags representing
the current alarm state of the ARU. If the state of the ARU is unknown, this variable is set to 'UNKNOWN'. The flags are numbered 1 to 8, read from left… |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.14.3.3.1.10 |
||||||||||||||||||||||||||||||||||||
|
rARUStatusAruCommStatusmandatory
The state of communications to the device.
commNeverDiscovered(1) indicates there has never been communications with this device. commsEstablished(2) indicates communication is normal and active with this device. commsL… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.14.3.3.1.11 |
||||||||||||||||||||||||||||||||||||
|
rARUStatusAruTempOvrdStatusmandatory
Specifies whether the ARU is increasing airflow because
exhaust air temperature has exceeded the setting specified in the rARUConfigAruTempOvrdSetpoint OID. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.14.3.3.1.12 |
||||||||||||||||||||||||||||||||||||
|
rARUStatusAruMasterControlmandatory
This is the master on/off control for the ARU.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.14.3.3.1.13 |
||||||||||||||||||||||||||||||||||||
|
rARUStatusAruTotalAirflowmandatory
The total airflow provided by the aru. Specified in cfm (cubic feet per minute).
Can be converted to metric values using the conversion factor: 1 cfm = 1.70 m^3/hr (cubic meters per hour). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.14.3.3.1.14 |
.1.3.6.1.4.1.318.1.1.14.4.1
·
1 row entry
·
11 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rARUFanStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rARUFanStatusTable'
Allows for query of the individual devices. The number of entries is contained in the rARUStatusAruDeviceCount OID.
The device to query.
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
rARUFanStatusAruIndexmandatory
The index to the ARU entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.14.4.1.1.1 |
||||||||||||||
|
rARUFanStatusNominalFanSpeedmandatory
The nominal rotational speed (RPM) of the fans when they are
operating at the 100% level. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.14.4.1.1.2 |
||||||||||||||
|
rARUFanStatusSelectedFanLevelmandatory
The currently selected ARU speed level,
specified in percent of full capacity. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.14.4.1.1.3 |
||||||||||||||
|
rARUFanStatusReplacementThresholdmandatory
Threshold above which a run hour alarm will exist, indicating
that it might be time to proactively replace a fan. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.14.4.1.1.4 |
||||||||||||||
|
rARUFanStatusFanIndexmandatory
The index to an individual fan table entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.14.4.1.1.5 |
||||||||||||||
|
rARUFanStatusFanOperatingStatusmandatory
The current operating state of the fan.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.14.4.1.1.6 |
||||||||||||||
|
rARUFanStatusFanRpmSpeedmandatory
The current rotational speed of the fan,
specified in rotations per minute (RPM). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.14.4.1.1.7 |
||||||||||||||
|
rARUFanStatusFanFlowRatemandatory
The flow rate provided by the fan, based on its measured rotational speed.
Specified in cfm (cubic feet per minute). Can be converted to metric values using the conversion factor: 1 cfm = 1.70 m^3/hr (cubic meters per h… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.14.4.1.1.8 |
||||||||||||||
|
rARUFanStatusFanInServiceDatemandatory
The installation/replacement date of the fan.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.14.4.1.1.9 |
||||||||||||||
|
rARUFanStatusFanRunhourCountermandatory
The total time for which the fan has been running.
Specified in 10ths of hours. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.14.4.1.1.10 |
||||||||||||||
|
rARUFanStatusFanRunhourResetmandatory
Writing yes to this This OID will reset a fan's total run hour counter,
which is shown in the rARUFanStatusFanRunhourCounter OID. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.14.4.1.1.11 |
.1.3.6.1.4.1.318.1.1.14.5.1
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rARUPowerStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rARUPowerStatusTable'
Allows for query of the individual ARUs accessible from this IP address. The number of entries is contained in the rARUStatusAruDeviceCount OID.
The device to query.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
rARUPowerStatusAruIndexmandatory
The index to the ARU entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.14.5.1.1.1 |
||||
|
rARUPowerStatusPrimaryAcPresentmandatory
Indicates whether or not line voltage is present on AC input 1.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.14.5.1.1.2 |
||||
|
rARUPowerStatusAuxiliaryAcPresentmandatory
Indicates whether or not line voltage is present on AC input 2.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.14.5.1.1.3 |
||||
|
rARUPowerStatusRedundantAcConfigmandatory
Indicates whether or not a dual cord is in use.
When this setting is set to dualCord (2), aruRedundantPowerLostAlarm traps will be generated when either primary or auxiliary input voltage is not present. When this setti… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.14.5.1.1.4 |
.1.3.6.1.4.1.318.1.1.14.6.2
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rARUSensorsStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rARUSensorsStatusTable'
Allows for getting environmental sensor status information.
The unit to get data from.
| Column | Syntax | OID |
|---|---|---|
|
rARUSensorsStatusAruIndexmandatory
The index to the ARU entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.14.6.2.1.1 |
|
rARUSensorsStatusSensorNumbermandatory
The number of the sensor on the device.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.14.6.2.1.2 |
|
rARUSensorsTemperaturemandatory
The sensor's current temperature reading. The temperature scale
is based on the system preferences configuration. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.14.6.2.1.3 |
.1.3.6.1.4.1.318.1.1.14.6.4
·
1 row entry
·
17 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rARUSensorsConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rARUSensorsConfigTable'
Allows for getting configuration information from environmental sensors attached to the device.
The unit to get data from.
| Column | Syntax | OID |
|---|---|---|
|
rARUSensorsConfigAruIndexmandatory
The index to the ARU entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.14.6.4.1.1 |
|
rARUSensorsConfigSensorNumbermandatory
The number of the sensor on the device.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.14.6.4.1.2 |
|
rARUSensorsNamemandatory
A descriptive name for the sensor.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.14.6.4.1.3 |
|
rARUSensorsLocationmandatory
The location of the sensor.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.14.6.4.1.4 |
|
rARUSensorsTempMaxThreshmandatory
The temperature at which a maximum temperature threshold
violation alarm will be generated for this sensor. The temperature scale is based on the system preferences configuration. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.14.6.4.1.5 |
|
rARUSensorsTempHighThreshmandatory
The temperature at which a high temperature threshold
violation alarm will be generated for this sensor. The temperature scale is based on the system preferences configuration. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.14.6.4.1.6 |
|
rARUSensorsTempLowThreshmandatory
The temperature at which a low temperature threshold
violation alarm will be generated for this sensor. The temperature scale is based on the system preferences configuration. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.14.6.4.1.7 |
|
rARUSensorsTempMinThreshmandatory
The temperature at which a min temperature threshold
violation alarm will be generated for this sensor. The temperature scale is based on the system preferences configuration. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.14.6.4.1.8 |
|
rARUSensorsTempThreshHysteresismandatory
The change in temperature required to cause a
temperature alarm to change from an active to an inactive state. The temperature scale is based on the system preferences configuration. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.14.6.4.1.9 |
|
The value of the temperature short-term decreasing rate
time that will cause an alarm to be generated. The temperature scale is based on the system preferences configuration. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.14.6.4.1.10 |
|
The time over which the temperature may not decrease
beyond the value specified by the temperature short-term decreasing rate threshold value. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.14.6.4.1.11 |
|
The value of the temperature short-term increasing rate
time that will cause an alarm to be generated. The temperature scale is based on the system preferences configuration. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.14.6.4.1.12 |
|
The time over which the temperature may not increase
beyond the value specified by the temperature short-term increasing rate threshold value. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.14.6.4.1.13 |
|
The value of the temperature long-term decreasing rate
time that will cause an alarm to be generated. The temperature scale is based on the system preferences configuration. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.14.6.4.1.14 |
|
rARUSensorsTempLongDecRateThreshTimemandatory
The time over which the temperature may not decrease
beyond the value specified by the temperature long-term decreasing rate threshold value. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.14.6.4.1.15 |
|
The value of the temperature long-term increasing rate
time that will cause an alarm to be generated. The temperature scale is based on the system preferences configuration. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.14.6.4.1.16 |
|
rARUSensorsTempLongIncRateThreshTimemandatory
The time over which the temperature may not increase
beyond the value specified by the temperature long-term increasing rate threshold value. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.14.6.4.1.17 |
.1.3.6.1.4.1.318.1.1.15.3.1.4
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk xPDUMainInputVoltagePhaseTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::xPDUMainInputVoltagePhaseTable'
A list of input voltage table entries. The number of entries are the phase entries. The number of entries is contained in the xPDUMainInputVoltageTableSize OID.
An entry containing information applicable to a
particular main input voltage phase.
particular main input voltage phase.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
xPDUMainInputVoltagePhaseIndexmandatory
Description of each input phase entry in the table.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.15.3.1.4.1.1 |
||||||
|
xPDUMainInputVoltageLtoLmandatory
Line-to-line PDU input voltage when an isolation transformer is present,
or -1 if no transformer present in this PDU. Measured in tenths of Volts. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.15.3.1.4.1.2 |
||||||
|
xPDUMainInputVoltageLtoNmandatory
Line-to-neutral PDU input voltage when an isolation transformer is not present,
or -1 if a transformer is present in this PDU. Measured in tenths of Volts. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.15.3.1.4.1.3 |
.1.3.6.1.4.1.318.1.1.15.3.2.4
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk xPDUBypassInputVoltagePhaseTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::xPDUBypassInputVoltagePhaseTable'
A list of output table entries. The number of entries are the phase entries. The number of entries is contained in the xPDUBypassInputVoltagePhaseTableSize OID.
An entry containing information applicable to a
particular bypass input voltage phase.
particular bypass input voltage phase.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
xPDUBypassInputVoltagePhaseIndexmandatory
Index of each bypass input phase entry in the table.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.15.3.2.4.1.1 |
||||||
|
xPDUBypassInputVoltageLtoLmandatory
Line-to-line bypass input voltage, or -1 if no bypass
feed is present in this PDU. Measured in tenths of Volts. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.15.3.2.4.1.2 |
||||||
|
xPDUBypassInputVoltageLtoNmandatory
Line-to-neutral bypass input voltage, or -1 if no bypass
feed is present in this PDU. Measured in tenths of Volts. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.15.3.2.4.1.3 |
.1.3.6.1.4.1.318.1.1.15.3.3.2
·
1 row entry
·
2 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk xPDUUPSInputVoltagePhaseTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::xPDUUPSInputVoltagePhaseTable'
A list of UPS input table entries. The number of entries are the phase entries. The number of entries is contained in the xPDUUPSInputVoltagePhaseTableSize OID.
An entry containing information applicable to a
particular UPS input voltage phase.
particular UPS input voltage phase.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
xPDUUPSInputVoltagePhaseIndexmandatory
Description of each UPS input phase entry in the table.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.15.3.3.2.1.1 |
||||||
|
xPDUUPSInputVoltageLtoNPresentmandatory
Indicates whether or not voltage is present at the UPS feed.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.15.3.3.2.1.2 |
.1.3.6.1.4.1.318.1.1.15.3.4.14
·
1 row entry
·
7 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk xPDUSystemOutputPhaseTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::xPDUSystemOutputPhaseTable'
A list of system output table entries. The number of entries is contained in the xPDUSystemOutputTableSize OID.
An entry containing information applicable to a
particular system output phase.
particular system output phase.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
xPDUSystemOutputPhaseIndexmandatory
Description of each output phase entry in the table.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.15.3.4.14.1.1 |
||||||
|
xPDUSystemOutputVoltageLtoLmandatory
Line-to-line system output voltage available at the circuit panel.
Measured in tenths of Volts. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.15.3.4.14.1.2 |
||||||
|
xPDUSystemOutputVoltageLtoNmandatory
Line-to-neutral system output voltage available at the circuit panel.
Measured in tenths of Volts. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.15.3.4.14.1.3 |
||||||
|
xPDUSystemOutputPhaseCurrentmandatory
System load current per phase. Measured in tenths of Amps.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.15.3.4.14.1.4 |
||||||
|
xPDUSystemOutputPowermandatory
System output power per phase. Measured in tenths of kW.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.15.3.4.14.1.5 |
||||||
|
xPDUSystemOutputApparentPowermandatory
System output power per phase. Measured in tenths of kVA.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.15.3.4.14.1.6 |
||||||
|
xPDUSystemOutputPowerFactormandatory
Indicates the Power Factor of the system output per phase.
A value of 100 representing a unity Power Factor (1.00). Measured in hundredths. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.15.3.4.14.1.7 |
.1.3.6.1.4.1.318.1.1.15.4.1.2
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk xPDUSystemBreakerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::xPDUSystemBreakerTable'
A list of system breaker entries. The number of entries is contained in the xPDUSystemBreakerTableSize OID.
An entry containing information applicable to a
particular system breaker.
particular system breaker.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
xPDUSystemBreakerTableIndexmandatory
Index of system breaker entries in the table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.15.4.1.2.1.1 |
||||||
|
xPDUSystemBreakerDescriptionmandatory
A brief description of the system breakers.
|
OctetString Constraints: range: 0-79 |
.1.3.6.1.4.1.318.1.1.15.4.1.2.1.2 |
||||||
|
xPDUSystemBreakerPositionmandatory
Indicates whether this breaker is open(1) or closed(2).
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.15.4.1.2.1.3 |
.1.3.6.1.4.1.318.1.1.15.4.2.3
·
1 row entry
·
11 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk xPDUBranchBreakerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::xPDUBranchBreakerTable'
A list of branch breaker table entries. The number of entries is given by the value of xPDUBranchBreakerTableSize The number of entries is contained in the xPDUBranchBreakerTableSize OID.
An entry containing information applicable to a
particular branch breaker (panel position).
particular branch breaker (panel position).
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
xPDUBranchBreakerTableIndexmandatory
Index of branch breaker entries in the table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.15.4.2.3.1.1 |
||||
|
xPDUBranchBreakerRatingmandatory
Indicates current rating of this breaker.
0=Breaker is not present. 1=Earth leakage connection. 2=Neutral connection. A value greater than 2 indicates breaker current rating in Amps. A value above 60 Amp will signify a … |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.15.4.2.3.1.2 |
||||
|
xPDUBranchBreakerRDPFeedmandatory
Indicates that a breaker position is feeding a remote
distribution panel. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.15.4.2.3.1.3 |
||||
|
xPDUBranchBreakerTieIndicatormandatory
Indicates whether or not the breaker in this position
is logically associated with the breaker immediately below it. This setting is used grouping the breakers feeding a multi-pole branch circuit. Note: When setting an … |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.15.4.2.3.1.4 |
||||
|
xPDUBranchBreakerCurrentmandatory
Indicates the branch current in tenths of Amps or -1 when not available.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.15.4.2.3.1.5 |
||||
|
Threshold above which a branch circuit high current
condition will be generated. Specified as a percent of the branch breaker rating. A value of zero indicates that the threshold is disabled. Note: When setting branch c… |
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.318.1.1.15.4.2.3.1.6 |
||||
|
Threshold below which a branch circuit low current
condition will be generated. Specified as a percent of the branch breaker rating. A value of zero indicates that the threshold is disabled. Note: When setting branch ci… |
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.318.1.1.15.4.2.3.1.7 |
||||
|
xPDUBranchBreakerMaxCurrentThresholdmandatory
Threshold above which a branch circuit maximum current
condition will be generated. Specified as a percent of the branch breaker rating. A value of zero indicates that the threshold is disabled. Note: When setting branc… |
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.318.1.1.15.4.2.3.1.8 |
||||
|
xPDUBranchBreakerMinCurrentThresholdmandatory
Threshold below which a branch circuit minimum current
condition will be generated. Specified as a percent of the branch breaker rating. A value of zero indicates that the threshold is disabled. Note: When setting branc… |
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.318.1.1.15.4.2.3.1.9 |
||||
|
xPDUBranchBreakerNamemandatory
The description of the purpose/use of the breaker.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.15.4.2.3.1.10 |
||||
|
xPDUBranchBreakerLocationmandatory
The description of the location of the breaker.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.15.4.2.3.1.11 |
.1.3.6.1.4.1.318.1.1.15.5.3
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk xPDUInputContactTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::xPDUInputContactTable'
A list of contacts supported by the PDU. The number of entries is contained in the xPDUInputContactTableSize OID.
A contact entry containing information for a given contact.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
xPDUInputContactNumbermandatory
An index identifying the contact on the PDU.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.15.5.3.1.1 |
||||||
|
xPDUInputContactNamemandatory
The description of the purpose/use of the contact.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.15.5.3.1.2 |
||||||
|
xPDUInputContactNormalStatemandatory
The normal operating position of the contact.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.15.5.3.1.3 |
||||||
|
xPDUInputContactCurrentStatemandatory
This value indicates the current state of the contact.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.15.5.3.1.4 |
.1.3.6.1.4.1.318.1.1.15.6.3
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk xPDUOutputRelayTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::xPDUOutputRelayTable'
A list of output relays supported by the PDU. The number of entries is contained in the xPDUOutputRelayTableSize OID.
A output relay entry containing information for a given contact.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
xPDUOutputRelayNumbermandatory
An index identifying the output relay on the PDU.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.15.6.3.1.1 |
||||||
|
xPDUOutputRelayNamemandatory
The description of the purpose/use of the output relay.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.15.6.3.1.2 |
||||||
|
xPDUOutputRelayNormalStatemandatory
The normal operating position of the output relay.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.15.6.3.1.3 |
||||||
|
xPDUOutputRelayCurrentStatemandatory
This value indicates the current state of the output relay.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.15.6.3.1.4 |
.1.3.6.1.4.1.318.1.1.16.3.2
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk battManUnitCalibTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::battManUnitCalibTable'
Allows for getting calibration information from each unit in the system.
The unit to get data from.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
battManUnitCalibIndexmandatory
Index of unit calibration entries in the table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.16.3.2.1.1 |
|
battManUnitSerialNumbermandatory
The serial number of the unit.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.16.3.2.1.2 |
|
battManBatteryVoltageZeroCalibmandatory
The unit battery voltage zero calibration in millivolts.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.16.3.2.1.3 |
|
battManBatteryVoltageSpanCalibmandatory
The unit battery voltage span calibration in hundredths of percent.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.16.3.2.1.4 |
.1.3.6.1.4.1.318.1.1.16.4.2
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk battManStringCalibTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::battManStringCalibTable'
Allows for getting calibration information from each string in the system.
The string to get data from.
Indexes
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
battManStringCalibIndexmandatory
Index of string calibration entries in the table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.16.4.2.1.1 |
||||||||||
|
battManDCCurrentZeroCalibmandatory
The string DC current zero calibration in tenths of amps.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.16.4.2.1.2 |
||||||||||
|
battManACCurrentZeroCalibmandatory
The string AC current zero calibration in tenths of amps.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.16.4.2.1.3 |
||||||||||
|
battManProbeRangemandatory
The string probe range in amps.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.16.4.2.1.4 |
.1.3.6.1.4.1.318.1.1.16.5.2
·
1 row entry
·
2 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk battManString1BatteryCalibTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::battManString1BatteryCalibTable'
Allows for getting calibration information from each battery in String 1.
The string to get data from.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
battManString1BatteryCalibIndexmandatory
Index of battery calibration entries in the table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.16.5.2.1.1 |
|
The battery inter-tier ohmic value in ohms. This corresponds to the ohmic
value for the positive terminal of the battery. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.16.5.2.1.2 |
.1.3.6.1.4.1.318.1.1.16.5.4
·
1 row entry
·
2 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk battManString2BatteryCalibTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::battManString2BatteryCalibTable'
Allows for getting calibration information from each battery in String 2.
The string to get data from.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
battManString2BatteryCalibIndexmandatory
Index of battery calibration entries in the table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.16.5.4.1.1 |
|
The battery inter-tier ohmic value in ohms.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.16.5.4.1.2 |
.1.3.6.1.4.1.318.1.1.16.9.2
·
1 row entry
·
13 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk battManStringTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::battManStringTable'
Allows for getting information from each string in the system.
The string to get data from.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
battManStringIndexmandatory
Index of string entries in the table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.16.9.2.1.1 |
||||
|
battManStringCurrentmandatory
The string current in tenths of amps.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.16.9.2.1.2 |
||||
|
battManStringRippleCurrentmandatory
The string ripple current in tenths of amps.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.16.9.2.1.3 |
||||
|
battManStringChargerHighVoltageAlarmmandatory
When set to alarm(2), indicates that the string charger has a high voltage alarm.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.16.9.2.1.4 |
||||
|
battManStringChargerLowVoltageAlarmmandatory
When set to alarm(2), indicates that the string charger has a low voltage alarm.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.16.9.2.1.5 |
||||
|
When set to alarm(2), indicates that the string charger probe is disconnected.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.16.9.2.1.6 |
||||
|
battManStringOnBatterymandatory
When set to alarm(2), indicates that the string is in the on-battery state.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.16.9.2.1.7 |
||||
|
battManStringHighRippleCurrentmandatory
When set to alarm(2), indicates that the string has a high ripple current.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.16.9.2.1.8 |
||||
|
battManStringVoltagemandatory
The sum of the voltages for all of the batteries on a
string in millivolts DC. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.16.9.2.1.9 |
||||
|
battManStringDischargeLess5Secondsmandatory
The number of recorded discharges lasting less than
5 seconds. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.16.9.2.1.10 |
||||
|
battManStringDischarge5to10Secondsmandatory
The number of recorded discharges lasting between 5
and 10 seconds. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.16.9.2.1.11 |
||||
|
battManStringDischarge10to60Secondsmandatory
The number of recorded discharges lasting between 10
and 60 seconds. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.16.9.2.1.12 |
||||
|
battManStringDischargeMore60Secondsmandatory
The number of recorded discharges lasting more than
60 seconds (1 minute). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.16.9.2.1.13 |
.1.3.6.1.4.1.318.1.1.16.10.2
·
1 row entry
·
14 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk battManString1BatteryTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::battManString1BatteryTable'
Allows for getting information from each string in the system.
The string to get data from.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
battManString1BatteryIndexmandatory
Index of string entries in the table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.16.10.2.1.1 |
||||
|
battManString1BatteryVoltagemandatory
The battery voltage in millivolts DC.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.16.10.2.1.2 |
||||
|
battManString1BatteryLowestVoltagemandatory
The lowest battery discharge voltage during the last power event in millivolts DC.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.16.10.2.1.3 |
||||
|
battManString1BatteryCellShortedmandatory
When set to alarm(2), indicates that a battery cell is shorted.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.16.10.2.1.4 |
||||
|
When set to alarm(2), indicates that a fuse or connection is open.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.16.10.2.1.5 |
||||
|
battManString1BatteryLowCapacitymandatory
When set to alarm(2), indicates a battery has low capacity.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.16.10.2.1.6 |
||||
|
battManString1BatteryHighOhmicValuemandatory
When set to alarm(2), indicates a battery has a high ohmic value.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.16.10.2.1.7 |
||||
|
battManString1BatteryThermalRunawaymandatory
When set to alarm(2), indicates a battery has a thermal runaway condition.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.16.10.2.1.8 |
||||
|
battManString1BatteryDryoutmandatory
When set to alarm(2), indicates a battery has a dryout condition.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.16.10.2.1.9 |
||||
|
When set to alarm(2), indicates a battery has violated
the user level high voltage limit. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.16.10.2.1.10 |
||||
|
When set to alarm(2), indicates a battery has violated
the user level low voltage limit. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.16.10.2.1.11 |
||||
|
When set to alarm(2), indicates a battery has violated
the chemistry level high voltage limit. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.16.10.2.1.12 |
||||
|
When set to alarm(2), indicates a battery has violated
the chemistry level low voltage limit. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.16.10.2.1.13 |
||||
|
battManString1BatteryOpenCellmandatory
When set to alarm(2), indicates the battery has an open
cell or an inter-connection is abnormal. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.16.10.2.1.14 |
.1.3.6.1.4.1.318.1.1.16.10.4
·
1 row entry
·
14 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk battManString2BatteryTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::battManString2BatteryTable'
Allows for getting information from each string in the system.
The string to get data from.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
battManString2BatteryIndexmandatory
Index of string entries in the table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.16.10.4.1.1 |
||||
|
battManString2BatteryVoltagemandatory
The battery voltage in millivolts DC.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.16.10.4.1.2 |
||||
|
battManString2BatteryLowestVoltagemandatory
The lowest battery discharge voltage during the last power event in millivolts DC.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.16.10.4.1.3 |
||||
|
battManString2BatteryCellShortedmandatory
When set to alarm(2), indicates that a battery cell is shorted.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.16.10.4.1.4 |
||||
|
When set to alarm(2), indicates that a fuse or connection is open.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.16.10.4.1.5 |
||||
|
battManString2BatteryLowCapacitymandatory
When set to alarm(2), indicates a battery has low capacity.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.16.10.4.1.6 |
||||
|
battManString2BatteryHighOhmicValuemandatory
When set to alarm(2), indicates a battery has a high ohmic value.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.16.10.4.1.7 |
||||
|
battManString2BatteryThermalRunawaymandatory
When set to alarm(2), indicates a battery has a thermal runaway condition.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.16.10.4.1.8 |
||||
|
battManString2BatteryDryoutmandatory
When set to alarm(2), indicates a battery has a dryout condition.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.16.10.4.1.9 |
||||
|
When set to alarm(2), indicates a battery has violated
the user level high voltage limit. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.16.10.4.1.10 |
||||
|
When set to alarm(2), indicates a battery has violated
the user level low voltage limit. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.16.10.4.1.11 |
||||
|
When set to alarm(2), indicates a battery has violated
the chemistry level high voltage limit. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.16.10.4.1.12 |
||||
|
When set to alarm(2), indicates a battery has violated
the chemistry level low voltage limit. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.16.10.4.1.13 |
||||
|
battManString2BatteryOpenCellmandatory
When set to alarm(2), indicates the battery has an open
cell or an inter-connection is abnormal. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.16.10.4.1.14 |
.1.3.6.1.4.1.318.1.1.16.11.2
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk battManInputContactTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::battManInputContactTable'
Allows for getting information from each contact in the system.
The contact to get data from.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
battManInputContactIndexmandatory
Index of contact entries in the table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.16.11.2.1.1 |
||||
|
battManInputContactNamemandatory
The name of the input contact.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.16.11.2.1.2 |
||||
|
battManInputContactAlarmStatemandatory
When set to alarm(2), indicates that the alarm condition is active for this contact.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.16.11.2.1.3 |
||||
|
battManInputContactStatemandatory
When set to open(1), the input contact is in the open state.
When set to closed(2), the input contact is in the closed state. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.16.11.2.1.4 |
||||
|
battManInputContactNormalStatemandatory
When set to open(1), the input contact is normally open.
When set to closed(2), the input contact is normally closed. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.16.11.2.1.5 |
||||
|
battManInputContactAlarmDelaymandatory
The input contact alarm delay time in seconds.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.16.11.2.1.6 |
.1.3.6.1.4.1.318.1.1.16.13.3
·
1 row entry
·
2 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk battManString1OhmicValueTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::battManString1OhmicValueTable'
Allows for getting ohmic value information from each battery in String 1.
The string to get data from.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
battManString1OhmicValueIndexmandatory
The battery number.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.16.13.3.1.1 |
|
battManString1OhmicValueDatamandatory
The battery inter-tier ohmic value in tenths of milli-Ohms.
Note: Zero or negative values are invalid and may indicate faulty calibration of ohmic value correction factors. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.16.13.3.1.2 |
.1.3.6.1.4.1.318.1.1.16.13.5
·
1 row entry
·
2 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk battManString1ResponseTestChangeTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::battManString1ResponseTestChangeTable'
Allows for getting response test change information from each battery in String 1.
The string to get data from.
| Column | Syntax | OID |
|---|---|---|
|
Index of the entries in the table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.16.13.5.1.1 |
|
battManString1ResponseTestChangeDatamandatory
The battery response test change in percent.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.16.13.5.1.2 |
.1.3.6.1.4.1.318.1.1.16.13.8
·
1 row entry
·
2 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk battManString2OhmicValueTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::battManString2OhmicValueTable'
Allows for getting ohmic value information from each battery in String 2.
The string to get data from.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
battManString2OhmicValueIndexmandatory
Index of battery calibration entries in the table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.16.13.8.1.1 |
|
battManString2OhmicValueDatamandatory
The battery inter-tier ohmic value in ohms.
Note: Zero or negative values are invalid and may indicate faulty calibration of ohmic value correction factors. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.16.13.8.1.2 |
.1.3.6.1.4.1.318.1.1.16.13.10
·
1 row entry
·
2 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk battManString2ResponseTestChangeTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::battManString2ResponseTestChangeTable'
Allows for getting response test change information from each battery in String 2.
The string to get data from.
| Column | Syntax | OID |
|---|---|---|
|
Index of the entries in the table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.16.13.10.1.1 |
|
battManString2ResponseTestChangeDatamandatory
The battery response test change in percent.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.16.13.10.1.2 |
.1.3.6.1.4.1.318.1.1.16.13.12
·
1 row entry
·
2 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk battManString1ResponseTestCurrentTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::battManString1ResponseTestCurrentTable'
Allows for getting response test current information from each battery in String 1.
The string to get data from.
.1.3.6.1.4.1.318.1.1.16.13.14
·
1 row entry
·
2 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk battManString2ResponseTestCurrentTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::battManString2ResponseTestCurrentTable'
Allows for getting response test current information from each battery in String 2.
The string to get data from.
.1.3.6.1.4.1.318.1.1.16.13.16
·
1 row entry
·
2 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk battManString1ResponseTestCurrentBenchmarkTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::battManString1ResponseTestCurrentBenchmarkTable'
Allows for getting response test current benchmark information from each battery in String 1.
The string to get data from.
.1.3.6.1.4.1.318.1.1.16.13.18
·
1 row entry
·
2 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk battManString2ResponseTestCurrentBenchmarkTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::battManString2ResponseTestCurrentBenchmarkTable'
Allows for getting response test current benchmark information from each battery in String 2.
The string to get data from.
.1.3.6.1.4.1.318.1.1.16.14.2
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk battManUnitStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::battManUnitStatusTable'
Allows for getting status information from each unit in the system.
The unit to get data from.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
battManUnitStatusIndexmandatory
Index of unit status entries in the table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.16.14.2.1.1 |
||||
|
battManUnitStatusSerialNumbermandatory
The battery manager unit serial number character string.
This value is set at the factory. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.16.14.2.1.2 |
||||
|
battManUnitHardwareRevmandatory
The battery manager unit hardware revision.
This value is set at the factory. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.16.14.2.1.3 |
||||
|
battManUnitFirmwareRevmandatory
The battery manager unit firmware revision.
This value is set at the factory and can change with firmware update. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.16.14.2.1.4 |
||||
|
battManUnitCommLossmandatory
When set to alarm(2), indicates the system has lost
communication with the unit. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.16.14.2.1.5 |
||||
|
battManUnitRelayStuckmandatory
When set to alarm(2), indicates the unit monitor relay
is stuck. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.16.14.2.1.6 |
.1.3.6.1.4.1.318.1.1.17.3.3.2
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk xATSSwitchTimersTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::xATSSwitchTimersTable'
A list of timers supported by ATS. The number of entries is contained in the xATSSwitchTimersTableSize OID.
An entry containing information about an individual ATS timer.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
xATSSwitchTimersIndexmandatory
Index of timer entries in the table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.17.3.3.2.1.1 |
||||
|
xATSSwitchTimersNamemandatory
Name of the individual timer.Refer to ATS operation manual,
or on-line help, for detailed descriptions of ATS timers. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.17.3.3.2.1.2 |
||||
|
xATSSwitchTimersAbortmandatory
This aborts the individual timer.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.17.3.3.2.1.3 |
||||
|
xATSSwitchTimersStatusmandatory
The status of the individual timer. Designates whether this timer
entry is currently running or inactive. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.17.3.3.2.1.4 |
||||
|
xATSSwitchTimersRemainingTimemandatory
The time remaining for this timer entry.
Specified in seconds. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.17.3.3.2.1.5 |
||||
|
xATSSwitchTimersDelaySettingmandatory
The delay settings associated with this timer entry.
When this timer entry is active, the timer value must exceed this setting before the ATS behavior associated with this timer is executed. Refer to ATS operation manua… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.17.3.3.2.1.6 |
.1.3.6.1.4.1.318.1.1.17.3.4.2
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk xATSSwitchBlockMapTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::xATSSwitchBlockMapTable'
A list of blocking maps supported by the ATS. The number of entries is contained in the xATSSwitchBlockMapTableSize OID.
An entry containing information about a specific ATS blocking map.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
xATSSwitchBlockMapIndexmandatory
Index of blocking map entries in the table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.17.3.4.2.1.1 |
|
xATSSwitchBlockMapNamemandatory
A string describing the ATS action to be blocked.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.17.3.4.2.1.2 |
|
xATSSwitchBlockMapStatusmandatory
Represents the status of this blocking map entry, in bit-mapped format.
A non-zero value indicates that this entry's ATS action is currently being blocked. The bit(s) set indicate which input(s) are causing the blocking… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.17.3.4.2.1.3 |
|
xATSSwitchBlockMapSettingmandatory
This setting designates the inputs that block the ATS action
The mapping is specified as a bit-field, where each bit set indicates the input that blocks the ATS action associated with the entry. bit 0 - C… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.17.3.4.2.1.4 |
.1.3.6.1.4.1.318.1.1.17.3.5.2
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk xATSSwitchStatisticsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::xATSSwitchStatisticsTable'
A list of statistics supported by ATS. The number of entries is contained in the xATSSwitchStatisticsTableSize OID.
An entry containing information about an individual ATS statistic.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
xATSSwitchStatisticsIndexmandatory
Index of ATS statistics entries in the table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.17.3.5.2.1.1 |
||||
|
xATSSwitchStatisticsNamemandatory
This is the name of the ATS statistic associated with this entry.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.17.3.5.2.1.2 |
||||
|
xATSSwitchStatisticsValuemandatory
This is the value of the ATS statistic associated with this entry.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.17.3.5.2.1.3 |
||||
|
xATSSwitchStatisticsResetmandatory
This will reset the individual ATS statistic associated with this entry.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.17.3.5.2.1.4 |
.1.3.6.1.4.1.318.1.1.17.4.1.7
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk xATSSource1PhaseTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::xATSSource1PhaseTable'
A list of voltage table entries for source 1. The number of entries are the phase entries. The number of entries is contained in the xATSSource1TableSize OID.
An entry containing information applicable to a
particular input voltage phase at the source 1 input of the ATS.
particular input voltage phase at the source 1 input of the ATS.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
xATSSource1Indexmandatory
Description of each phase utilized at source 1.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.17.4.1.7.1.1 |
||||||
|
xATSSource1VoltageLtoLmandatory
Source 1 line-to-line input voltage.
Measured in tenths of Volts. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.17.4.1.7.1.2 |
||||||
|
xATSSource1VoltageLtoNmandatory
Source 1 line-to-neutral input voltage.
Measured in tenths of Volts. -1 for a 3-wire service type. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.17.4.1.7.1.3 |
.1.3.6.1.4.1.318.1.1.17.4.2.7
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk xATSSource2PhaseTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::xATSSource2PhaseTable'
A list of voltage table entries for the source 2. The number of entries are the phase entries. The number of entries is contained in the xATSSource2TableSize OID.
An entry containing information applicable to a
particular input voltage phase at the source 2 input of the ATS.
particular input voltage phase at the source 2 input of the ATS.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
xATSSource2Indexmandatory
Description of each phase utilized at the source 2.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.17.4.2.7.1.1 |
||||||
|
xATSSource2VoltageLtoLmandatory
Source 2 line-to-line input voltage.
Measured in tenths of Volts. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.17.4.2.7.1.2 |
||||||
|
xATSSource2VoltageLtoNmandatory
Source 2 line-to-neutral input voltage.
Measured in tenths of Volts. -1 for a 3-wire service type. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.17.4.2.7.1.3 |
.1.3.6.1.4.1.318.1.1.17.4.3.12
·
1 row entry
·
7 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk xATSSystemOutputPhaseTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::xATSSystemOutputPhaseTable'
A list of system output table entries. The number of entries is contained in the xATSSystemOutputTableSize OID.
An entry containing information applicable to a
particular system output phase.
particular system output phase.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
xATSSystemOutputPhaseIndexmandatory
Description of each system output phase utilized in this device.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.17.4.3.12.1.1 |
||||||
|
xATSSystemOutputVoltageLtoLmandatory
Line-to-line system output voltage available at the circuit panel.
Measured in tenths of Volts. -1 if not available. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.17.4.3.12.1.2 |
||||||
|
xATSSystemOutputVoltageLtoNmandatory
Line-to-neutral system output voltage available at the circuit panel.
Measured in tenths of Volts. -1 for a 3-wire service type or if not available. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.17.4.3.12.1.3 |
||||||
|
xATSSystemOutputPhaseCurrentmandatory
System load current per phase. Measured in Amps.
-1 if not available. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.17.4.3.12.1.4 |
||||||
|
xATSSystemOutputPowermandatory
System output power per phase. Measured in tenths of kW.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.17.4.3.12.1.5 |
||||||
|
xATSSystemOutputApparentPowermandatory
system output power per phase. Measured in tenths of kVA.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.17.4.3.12.1.6 |
||||||
|
xATSSystemOutputPowerFactormandatory
indicates the power factor of the system output per phase.
A value of 100 representing a unity power factor (1.00). Measured in hundredths. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.17.4.3.12.1.7 |
.1.3.6.1.4.1.318.1.1.17.6.3
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk xATSInputContactTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::xATSInputContactTable'
A list of contacts supported by the ATS. The number of entries is contained in the xATSInputContactTableSize OID.
A contact entry containing information for a given contact.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
xATSInputContactNumbermandatory
An index identifying the contact on the ATS.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.17.6.3.1.1 |
||||
|
xATSInputContactNamemandatory
The description of the purpose/use of the contact.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.17.6.3.1.2 |
||||
|
xATSInputContactNormalStatemandatory
The normal operating position of the contact.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.17.6.3.1.3 |
||||
|
xATSInputContactCurrentStatemandatory
This value indicates the current state of the contact.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.17.6.3.1.4 |
.1.3.6.1.4.1.318.1.1.17.7.3
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk xATSOutputRelayTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::xATSOutputRelayTable'
A list of output relays supported by the ATS. The number of entries is contained in the xATSOutputRelayTableSize OID.
A output relay entry containing information for a given contact.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
xATSOutputRelayNumbermandatory
An index identifying the output relay on the ATS.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.17.7.3.1.1 |
||||
|
xATSOutputRelayNamemandatory
The description of the purpose/use of the output relay.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.17.7.3.1.2 |
||||
|
xATSOutputRelayNormalStatemandatory
The normal operating position of the output relay.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.17.7.3.1.3 |
||||
|
xATSOutputRelayCurrentStatemandatory
This value indicates the current state of the output relay.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.17.7.3.1.4 |
.1.3.6.1.4.1.318.1.1.18.1.4.6
·
1 row entry
·
7 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk xATSGeneratorOutputPhaseTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::xATSGeneratorOutputPhaseTable'
A list of generator output table entries. The number of entries is contained in the xATSGeneratorOutputTableSize OID.
An entry containing information applicable to a
particular generator output phase.
particular generator output phase.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
xATSGeneratorOutputPhaseIndexmandatory
Description of each generator output phase utilized in this device.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.18.1.4.6.1.1 |
||||||
|
xATSGeneratorOutputVoltageLtoLmandatory
Line-to-line generator output voltage.
Measured in Volts, or -1 if not available. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.18.1.4.6.1.2 |
||||||
|
xATSGeneratorOutputVoltageLtoNmandatory
Line-to-neutral generator output voltage.
Measured in volts, or -1 if not available. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.18.1.4.6.1.3 |
||||||
|
xATSGeneratorOutputPhaseCurrentmandatory
Generator load current per phase.
Measured in Amps, or -1 if not available. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.18.1.4.6.1.4 |
||||||
|
xATSGeneratorOutputPowermandatory
Generator output power per phase.
Measured in tenths of kW, or -1 if not available. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.18.1.4.6.1.5 |
||||||
|
xATSGeneratorOutputApparentPowermandatory
Generator output power per phase.
Measured in tenths of kVA, or -1 if not available. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.18.1.4.6.1.6 |
||||||
|
xATSGeneratorOutputPowerFactormandatory
Indicates the load power factor of the generator output per phase.
A value of 100 representing a unity power factor (1.00), or -1 if not available. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.18.1.4.6.1.7 |
.1.3.6.1.4.1.318.1.1.19.1.1.4.2
·
1 row entry
·
5 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk cpsCardIdentTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::cpsCardIdentTable'
A table of PCMCIA card identifications.
Identification information for a PCMCIA card.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
cpsCardIdentIndexmandatory
Number to identify the socket Card.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.1.4.2.1.1 |
|
cpsCardIdentProdmandatory
Product identification string.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.19.1.1.4.2.1.2 |
|
cpsCardIdentManmandatory
Manufacturer ID code.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.19.1.1.4.2.1.3 |
|
cpsCardIdentFuncmandatory
Function ID code.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.19.1.1.4.2.1.4 |
|
cpsCardIdentPCImandatory
PCI ID
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.19.1.1.4.2.1.5 |
.1.3.6.1.4.1.318.1.1.19.1.1.4.3
·
1 row entry
·
8 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk cpsCardConfTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::cpsCardConfTable'
A table of socket configuration information.
Configuration information for a socket.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
cpsCardConfIndexmandatory
Number to identify the socket PCMCIA.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.1 |
|
cpsCardConfPowermandatory
Power Settings.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.2 |
|
cpsCardConfTypemandatory
Interface Type.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.3 |
|
cpsCardConfIntermandatory
Interrupt number.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.4 |
|
cpsCardConfFuncmandatory
Function.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.5 |
|
cpsCardConfCardvmandatory
Card values.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.6 |
|
cpsCardConfPort1mandatory
I/O Port 1.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.7 |
|
cpsCardConfPort2mandatory
I/O Port 2.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.19.1.1.4.3.1.8 |
.1.3.6.1.4.1.318.1.1.19.1.1.4.4
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk cpsCardStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::cpsCardStatusTable'
A table of current socket status information.
Current status information for a socket.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
cpsCardStatusIndexmandatory
Number to identify the socket PCMCIA.
|
Integer32 Constraints: range: 0-2 |
.1.3.6.1.4.1.318.1.1.19.1.1.4.4.1.1 |
|
cpsCardStatusCardmandatory
Current Card State.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.19.1.1.4.4.1.2 |
|
cpsCardStatusFuncmandatory
Current Function.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.19.1.1.4.4.1.3 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.1.11
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk cpsSerialGroupTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::cpsSerialGroupTable'
Indexes
| Column | Syntax | OID |
|---|---|---|
|
cpsSerialGroupIndexmandatory
Number to identify the group.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.1.11.1.1 |
|
cpsSerialGroupNamemandatory
The group name.
|
OctetStringr/w Constraints: range: 0-20 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.1.11.1.2 |
|
cpsSerialGroupUsersmandatory
The user's names.
|
OctetStringr/w Constraints: range: 0-80 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.1.11.1.3 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1
·
1 row entry
·
58 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk cpsSerialPortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::cpsSerialPortTable'
This is the specific configuration per serial port.
One particular serial port configuration.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
cpsSerialPortNumbermandatory
Number to identify the serial port. Value 0 is ALL.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.1 |
|
cpsSerialPortTtymandatory
The device name for the serial port.
|
OctetStringr/w Constraints: range: 0-25 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.2 |
|
cpsSerialPortNamemandatory
Alias name given to the server connected to the serial port.
|
OctetStringr/w Constraints: range: 0-40 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.3 |
|
cpsSerialPortSpeedmandatory
The speed of the serial port.
Supported values are: 50, 75, 110, 134, 150, 200, 300, 600, 1200, 1800, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 115200, 230400, and 460800 |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.4 |
|
cpsSerialPortDataSizemandatory
The data size for the serial port.
|
Integer32r/w Constraints: range: 4-8 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.5 |
|
cpsSerialPortStopBitsmandatory
The number of stop bits for the serial port.
|
Integer32r/w Constraints: range: 0-2 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.6 |
|
cpsSerialPortParitymandatory
The parity for the serial port.
|
OctetStringr/w Constraints: range: 0-5 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.7 |
|
cpsSerialPortFlowCtrlmandatory
The flow control for the serial port.
|
OctetStringr/w Constraints: range: 0-5 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.8 |
|
cpsSerialPortDTRdelaymandatory
This specifies how long (in milliseconds) a DTR signal
will be turned off before it is turned on again. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.9 |
|
cpsSerialPortDCDCtrlmandatory
DCD signal controls the connection request.
0 will indicate nocontrol, 1 will indicate control. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.10 |
|
cpsSerialPortLogUtmpmandatory
Update the login records in /var/run/utmp file.
0 will indicate inactive, 1 will indicate active. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.11 |
|
cpsSerialPortLogWtmpmandatory
Update the login records in /var/run/wtmp file.
0 will indicate inactive, 1 will indicate active. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.12 |
|
cpsSerialPortLogformmandatory
This is the format to write the login record.
|
OctetStringr/w Constraints: range: 0-40 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.13 |
|
cpsSerialPortAuthtypemandatory
Authentication type.
|
OctetStringr/w Constraints: range: 0-25 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.14 |
|
cpsSerialPortAuthSrv1mandatory
IP address of the primary authentication server.
|
RFC1155-SMIIpAddressr/w Type Constraints: range: 4 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.15 |
|
cpsSerialPortAccSrv1mandatory
IP address of the primary accounting server.
|
RFC1155-SMIIpAddressr/w Type Constraints: range: 4 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.16 |
|
cpsSerialPortAuthTmomandatory
This is the timeout (in seconds) for the authentication
query to be answered. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.17 |
|
cpsSerialPortAuthRetrmandatory
This defines the number of times each server is tried
before another is contacted. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.18 |
|
cpsSerialPortAuthSrv2mandatory
IP address of the secondary authentication server.
|
RFC1155-SMIIpAddressr/w Type Constraints: range: 4 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.19 |
|
cpsSerialPortAccSrv2mandatory
IP address of the secondary accounting server.
|
RFC1155-SMIIpAddressr/w Type Constraints: range: 4 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.20 |
|
cpsSerialPortAuthSecretmandatory
This is the shared secret with authentication servers.
|
OctetStringr/w Constraints: range: 0-40 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.21 |
|
cpsSerialPortAuthRadPmandatory
Radius state.
0 will indicate inactive, 1 will indicate active. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.22 |
|
cpsSerialPortAuthAccmandatory
Access restriction.
|
OctetStringr/w Constraints: range: 0-40 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.23 |
|
cpsSerialPortProtocolmandatory
Defines the serial port's protocol.
|
OctetStringr/w Constraints: range: 0-40 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.24 |
|
cpsSerialPortRemoteIPmandatory
This is the default IP address of the serial port.
|
OctetStringr/w Constraints: range: 0-20 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.25 |
|
cpsSerialPortSocketPortmandatory
This defines an alternative labeling system for the serial port.
|
OctetStringr/w Constraints: range: 0-10 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.26 |
|
cpsSerialPortRemHostmandatory
The IP address of the host to which the serial port will connect.
|
RFC1155-SMIIpAddressr/w Type Constraints: range: 4 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.27 |
|
cpsSerialPortBannermandatory
This defines the banner.
|
OctetStringr/w Constraints: range: 0-250 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.28 |
|
cpsSerialPortPromptmandatory
This defines the login prompt to the serial port.
|
OctetStringr/w Constraints: range: 0-250 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.29 |
|
cpsSerialPortTermTypemandatory
This defines the terminal type.
|
OctetStringr/w Constraints: range: 0-20 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.30 |
|
cpsSerialPortAutomUsrmandatory
This defines the automatic user.
|
OctetStringr/w Constraints: range: 0-40 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.31 |
|
cpsSerialPortNetMaskmandatory
The network mask used in dial in connection.
|
RFC1155-SMIIpAddressr/w Type Constraints: range: 4 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.32 |
|
cpsSerialPortPppMtumandatory
The PPP MTU - dial in connection.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.33 |
|
cpsSerialPortPppMrumandatory
The PPP MRU - dial in connection.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.34 |
|
cpsSerialPortPppOptionsmandatory
The PPP options when the PPP session is autodetected.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.35 |
|
cpsSerialPortPppFoptionmandatory
The PPP forced options when the user has already been authenticated.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.36 |
|
cpsSerialPortModemChatmandatory
The initchat send to modem connected.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.37 |
|
cpsSerialPortSttyCmdmandatory
The tty settings after socket connection is established.
|
OctetStringr/w Constraints: range: 0-180 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.38 |
|
cpsSerialPortSockTxmandatory
Defines the delay (in milliseconds) before transmission to
the Ethernet of data received through a serial port. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.39 |
|
cpsSerialPortSockPollmandatory
Keep-alive timer (milliseconds) for the TCP connection.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.40 |
|
cpsSerialPortSockIdlemandatory
The idle timeout in seconds.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.41 |
|
cpsSerialPortDBsizemandatory
Maximum size of the data buffering file.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.42 |
|
cpsSerialPortDBtimemandatory
Timestamp in data buffering.
0 will indicate inactive, 1 will indicate active. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.43 |
|
cpsSerialPortDBmodemandatory
Data buffering mode : circ or line.
|
OctetStringr/w Constraints: range: 0-5 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.44 |
|
cpsSerialPortDBsyslogmandatory
Size of the data buffer sent to syslog.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.45 |
|
cpsSerialPortDBmenumandatory
Menu type for data buffering.
0 will indicate display Menu, 1 will indicate inactive, 2 will indicate DB, 3 will indicate Parc. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.46 |
|
cpsSerialPortDBalarmmandatory
Alarm generation status.
0 will indicate inactive, 1 will indicate active. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.47 |
|
cpsSerialPortSSHbreakmandatory
Break sequence - ssh session.
|
OctetStringr/w Constraints: range: 0-16 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.48 |
|
cpsSerialPortSniffSessmandatory
Sniff session type.
|
OctetStringr/w Constraints: range: 0-5 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.49 |
|
cpsSerialPortSniffAdmmandatory
List of admin users allowed to sniff session.
|
OctetStringr/w Constraints: range: 0-40 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.50 |
|
cpsSerialPortSniffEscmandatory
Escape sequence used in sniff session.
|
OctetStringr/w Constraints: range: 0-6 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.51 |
|
cpsSerialPortSniffMsessmandatory |
OctetStringr/w Constraints: range: 0-20 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.52 |
|
cpsSerialPortTelnetModemandatory
Mode negotiated by client telnet with the server.
0 will indicate text, 1 will indicate binary. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.53 |
|
cpsSerialPortSysBufSessmandatory
Syslog Buffering at all times.
0 will indicate yes, 1 will indicate no. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.54 |
|
cpsSerialPortLFSuppressmandatory
LF suppression in socket_server session.
0 will indicate inactive, 1 will indicate active. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.55 |
|
cpsSerialPortAutoInputmandatory
Input string used for auto answer.
|
OctetStringr/w Constraints: range: 0-40 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.56 |
|
cpsSerialPortAutoOutputmandatory
Output string used for auto answer.
|
OctetStringr/w Constraints: range: 0-40 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.57 |
|
cpsSerialPortBreakIntervalmandatory
The break interval in milliseconds.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.2.6.2.1.1.58 |
.1.3.6.1.4.1.318.1.1.19.1.3.1
·
1 row entry
·
16 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk cpsInfoSerialPortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::cpsInfoSerialPortTable'
This is the information of the specific serial port.
One particular serial port.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
cpsInfoSerialPortNumbermandatory
Number to identify the serial port.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.3.1.1.1 |
|
cpsInfoSerialPortTtymandatory
The device name for the serial port.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.19.1.3.1.1.2 |
|
cpsInfoSerialPortNamemandatory
Alias name given to the server connected to the serial port.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.19.1.3.1.1.3 |
|
cpsInfoSerialPortSpeedmandatory
The speed for serial port.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.3.1.1.4 |
|
cpsInfoSerialPortTxBytesmandatory
The number of transmitted bytes by the serial port.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.3.1.1.5 |
|
cpsInfoSerialPortRXBytesmandatory
The number of received bytes by the serial port.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.3.1.1.6 |
|
cpsInfoSerialPortErrFramemandatory
The number of frame errors.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.3.1.1.7 |
|
cpsInfoSerialPortErrParitymandatory
The number of parity errors.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.3.1.1.8 |
|
cpsInfoSerialPortErrBreaksmandatory
The number of breaks errors.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.3.1.1.9 |
|
cpsInfoSerialPortErrOverrunmandatory
The number of overrun errors.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.3.1.1.10 |
|
cpsInfoSerialPortSigDTRmandatory
The state of the DTR signal.
0 will indicate down, 1 will indicate up. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.3.1.1.11 |
|
cpsInfoSerialPortSigCDmandatory
The state of the DCD signal.
0 will indicate down, 1 will indicate up. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.3.1.1.12 |
|
cpsInfoSerialPortSigDSRmandatory
The state of the DSR signal.
0 will indicate down, 1 will indicate up. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.3.1.1.13 |
|
cpsInfoSerialPortSigRTSmandatory
The state of the RTS signal.
0 will indicate down, 1 will indicate up. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.3.1.1.14 |
|
cpsInfoSerialPortSigCTSmandatory
The state of the CTS signal.
0 will indicate down, 1 will indicate up. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.3.1.1.15 |
|
cpsInfoSerialPortSigRImandatory
The state of the RI signal.
0 will indicate down, 1 will indicate up. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.19.1.3.1.1.16 |
.1.3.6.1.4.1.318.1.1.22.1.2
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk isxModularDistInfoTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::isxModularDistInfoTable'
Allows for getting information about the modular distribution metering equipment.
An entry containing information about an individual metering segment.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
isxModularDistInfoSegmentIndexmandatory
The index of the metering segment.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.1.2.1.1 |
|
isxModularDistInfoMeterModelNumbermandatory
The model number of the metering board for this segment.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.22.1.2.1.2 |
|
isxModularDistInfoMeterSerialNumbermandatory
The serial number of the metering board for this segment.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.22.1.2.1.3 |
|
The date of manufacture for the metering board for this segment,
in the format mm/dd/yyyy. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.22.1.2.1.4 |
|
isxModularDistInfoMeterFirmwareRevmandatory
The firmware revision number of the metering board for this segment.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.22.1.2.1.5 |
|
isxModularDistInfoMeterHardwareRevmandatory
The hardware revision number of the metering board for this segment.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.22.1.2.1.6 |
.1.3.6.1.4.1.318.1.1.22.2.2
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk isxModularDistModuleInfoTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::isxModularDistModuleInfoTable'
Allows for getting basic information about the distribution modules installed in the system.
An entry containing information about a specific distribution module.
Indexes
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
isxModularDistModuleInfoModIndexmandatory
The number of the distribution module.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.2.2.1.1 |
||||||||||
|
isxModularDistModuleInfoAlarmStatusmandatory
The status of this module. This reflects the indicator lamp(s) on the front of the module.
A value of notPresent indicates that the module is not installed. A value of unknown indicates that there is no communication wi… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.22.2.2.1.2 |
||||||||||
|
isxModularDistModuleInfoModelNumbermandatory
The model number of the distribution module.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.22.2.2.1.3 |
||||||||||
|
isxModularDistModuleInfoSerialNumbermandatory
The serial number of the distribution module.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.22.2.2.1.4 |
||||||||||
|
The date that the distribution module was manufactured.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.22.2.2.1.5 |
||||||||||
|
isxModularDistModuleInfoNumCablesmandatory
The number of cables provided by this distribution module.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.2.2.1.6 |
.1.3.6.1.4.1.318.1.1.22.2.4
·
1 row entry
·
11 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk isxModularDistModuleBreakerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::isxModularDistModuleBreakerTable'
Allows for getting operational information about the distribution modules.
An entry containing information about a specific distribution modules and circuit breakers.
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
isxModularDistModuleBreakerModIndexmandatory
The distribution module number.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.2.4.1.1 |
||||||
|
The index to an individual breaker in the distribution module. The index also corresponds
to the system phase to which the breaker is attached. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.22.2.4.1.2 |
||||||
|
This is a bit map representing the active alarms for this breaker:
b0 - Minimum current threshold exceeded (critical) b1 - Low current threshold exceeded (warning) b2 - High current threshold exceeded (wa… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.2.4.1.3 |
||||||
|
isxModularDistModuleBreakerRatingmandatory
The current rating of the breaker.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.2.4.1.4 |
||||||
|
Numeric value used to indicate that a breaker is a part of a multi-pole breaker.
Breakers within a distribution module, with equivalent physical group numbers, may have their handles physically tied together. A value of… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.2.4.1.5 |
||||||
|
isxModularDistModuleBreakerCableNummandatory
Numeric value used to indicate the distribution cable to which
this breaker is connected. These distribution cables are described in the table isxModularDistModuleOutputTable, and indexed by the OID isxModularDistModule… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.2.4.1.6 |
||||||
|
isxModularDistModuleBreakerPositionmandatory
The physical status of this breaker pole, either closed or open (including tripped).
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.22.2.4.1.7 |
||||||
|
Enable or disable breaker position alarms for this circuit breaker.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.22.2.4.1.8 |
||||||
|
isxModularDistModuleBreakerCurrentmandatory
The current flowing though this breaker. Measured in tenths of amps.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.2.4.1.9 |
||||||
|
isxModularDistModuleBreakerPercentmandatory
The loading on this breaker as a percentage of the breaker's current rating.
Expressed in tenths of percent. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.2.4.1.10 |
||||||
|
isxModularDistModuleBreakerPowermandatory
The power being supplied through this breaker. Measured in tenths of kW.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.2.4.1.11 |
.1.3.6.1.4.1.318.1.1.22.2.6
·
1 row entry
·
23 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk isxModularDistModuleOutputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::isxModularDistModuleOutputTable'
Allows for getting and setting information related to the load equipment being fed by the distribution modules in the ISX Modular Distribution System.
An entry containing information about a specific distribution module
and its output distribution cables.
and its output distribution cables.
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
isxModularDistModuleOutputModIndexmandatory
The number of the distribution module supplying power to the load equipment.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.2.6.1.1 |
||||||||||
|
isxModularDistModuleOutputNumCablesmandatory
The number of distribution cables provided by this module.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.2.6.1.2 |
||||||||||
|
isxModularDistModuleOutputCordIndexmandatory
The index of an individual distribution cable supplied by this module.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.2.6.1.3 |
||||||||||
|
isxModularDistModuleOutputNamemandatory
A string describing the load equipment being supplied by this distribution cable.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.22.2.6.1.4 |
||||||||||
|
isxModularDistModuleOutputLocationmandatory
A string describing the location of equipment being supplied by distribution cable.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.22.2.6.1.5 |
||||||||||
|
isxModularDistModuleOutputStatusmandatory
This reflects the worse case severity for alarms associated with this distribution cable.
A value of notPresent indicates that the cable does not exist for this module. A value of unknown indicates that the there is no … |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.22.2.6.1.6 |
||||||||||
|
Enable or disable all alarm generation related to this distribution cable.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.22.2.6.1.7 |
||||||||||
|
isxModularDistModuleOutputBreakerMapmandatory
This is a bit map representing the breaker poles within the
module that are associated with this distribution cable. The following 3 bits are used to indicate the indices of the breakers feeding the cable: … |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.2.6.1.8 |
||||||||||
|
When the current drops below this value a critical alarm will exist.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.2.6.1.9 |
||||||||||
|
When the current drops below this value a warning alarm will exist.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.2.6.1.10 |
||||||||||
|
When the current exceeds this value a warning alarm will exist.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.2.6.1.11 |
||||||||||
|
When the current exceeds this value a critical alarm will exist.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.2.6.1.12 |
||||||||||
|
Enable or disable minimum current alarm generation for this distribution cable.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.22.2.6.1.13 |
||||||||||
|
Enable or disable low current alarm generation for this distribution cable.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.22.2.6.1.14 |
||||||||||
|
Enable or disable high current alarm generation for this distribution cable.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.22.2.6.1.15 |
||||||||||
|
Enable or disable maximum current alarm generation for this distribution cable.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.22.2.6.1.16 |
||||||||||
|
The length of this distribution cable. Specified in tenths of meters.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.2.6.1.17 |
||||||||||
|
A string describing the connector on the end of this distribution cable.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.22.2.6.1.18 |
||||||||||
|
This is a bit map representing the voltages that are available at the connector.
6 bits are used to indicate the following: b0 - L1 b1 - L2 b2 - L3 b3 - L1-2 b4 - L2-3 b5 - L3-1 |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.2.6.1.19 |
||||||||||
|
isxModularDistModuleOutputTotalPowermandatory
The total power being consumed by the load equipment supplied by this distribution cable.
Measured in tenths of kW. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.2.6.1.20 |
||||||||||
|
isxModularDistModuleOutputKwhUsagemandatory
The total energy consumed by the load equipment fed by this distribution cable.
This is the total since the date specified in the isxModularDistModuleOutputKwhResetDate OID, and may be cleared using the isxModularDistMo… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.2.6.1.21 |
||||||||||
|
isxModularDistModuleOutputKwhResetmandatory
Writing yes to this OID will reset the total kWh usage shown
in the isxModularDistModuleOutputKwhUsage OID. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.22.2.6.1.22 |
||||||||||
|
The date that the kWh usage was reset, in the format mm/dd/yyyy. Example: 01/01/2000.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.22.2.6.1.23 |
.1.3.6.1.4.1.318.1.1.22.3.2
·
1 row entry
·
20 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk isxModularDistSubFeedInfoTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::isxModularDistSubFeedInfoTable'
Allows for getting information about distribution subfeed breakers.
An entry containing information about a specific distribution subfeed.
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
isxModularDistSubFeedInfoSubIndexmandatory
The index of an individual subfeed.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.3.2.1.1 |
||||||
|
isxModularDistSubFeedInfoNamemandatory
A string describing the load equipment being supplied by this subfeed.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.22.3.2.1.2 |
||||||
|
isxModularDistSubFeedInfoLocationmandatory
A string describing the location of the equipment being supplied by this subfeed.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.22.3.2.1.3 |
||||||
|
The current rating of this subfeed breaker.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.3.2.1.4 |
||||||
|
The operational status of this breaker, either closed or open (including tripped).
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.22.3.2.1.5 |
||||||
|
isxModularDistSubFeedInfoAlarmStatusmandatory
The worst case alarm status for this subfeed.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.22.3.2.1.6 |
||||||
|
Enable or disable all alarm generation related to this subfeed.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.22.3.2.1.7 |
||||||
|
When the current drops below this value a critical alarm will exist.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.3.2.1.8 |
||||||
|
When the current drops below this value a warning alarm will exist.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.3.2.1.9 |
||||||
|
When the current exceeds this value a warning alarm will exist.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.3.2.1.10 |
||||||
|
When the current exceeds this value a critical alarm will exist.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.3.2.1.11 |
||||||
|
Enable or disable minimum current alarm generation for this subfeed.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.22.3.2.1.12 |
||||||
|
Enable or disable low current alarm generation for this subfeed.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.22.3.2.1.13 |
||||||
|
Enable or disable high current alarm generation for this subfeed.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.22.3.2.1.14 |
||||||
|
Enable or disable maximum current alarm generation for this subfeed.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.22.3.2.1.15 |
||||||
|
Enable or disable breaker position alarms for this subfeed.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.22.3.2.1.16 |
||||||
|
isxModularDistSubFeedInfoTotalPowermandatory
The total power being supplied by this subfeed. Measured in tenths of kW.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.3.2.1.17 |
||||||
|
isxModularDistSubFeedInfoKwhUsagemandatory
The total energy consumed by the load equipment fed by this subfeed.
This is the total since the date specified in the isxModularDistSubFeedInfoKwhResetDate OID, and may be cleared using the isxModularDistSubFeedInfoKwh… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.3.2.1.18 |
||||||
|
isxModularDistSubFeedInfoKwhResetmandatory
Writing yes to this OID will reset the total kWh usage shown
in the isxModularDistSubFeedInfoKwhUsage OID. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.22.3.2.1.19 |
||||||
|
The date that the kWh usage was reset, in the format mm/dd/yyyy. Example: 01/01/2000.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.22.3.2.1.20 |
.1.3.6.1.4.1.318.1.1.22.3.4
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk isxModularDistSubFeedLoadingTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::isxModularDistSubFeedLoadingTable'
Allows for getting subfeed phase loading information.
An entry containing data for an individual subfeed.
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
isxModularDistSubFeedLoadingSubIndexmandatory
The index of an individual subfeed.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.3.4.1.1 |
||||||
|
Description of each input phase entry in the table.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.22.3.4.1.2 |
||||||
|
This is a bit map representing the active alarms for this subfeed:
b0 - Minimum current threshold exceeded (critical) b1 - Low current threshold exceeded (warning) b2 - High current threshold exceeded (wa… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.3.4.1.3 |
||||||
|
isxModularDistSubFeedLoadingCurrentmandatory
The current flowing though this subfeed phase. Measured in tenths of amps.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.3.4.1.4 |
||||||
|
isxModularDistSubFeedLoadingPercentmandatory
The loading on this subfeed phase as a percentage of the subfeed's current rating.
Expressed in tenths of percent. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.3.4.1.5 |
||||||
|
isxModularDistSubFeedLoadingPowermandatory
The power being supplied by this subfeed phase. Measured in tenths of kW.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.3.4.1.6 |
.1.3.6.1.4.1.318.1.1.22.4.1.15
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk isxModularDistSysVoltageTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::isxModularDistSysVoltageTable'
Allows for getting the system output voltage information.
An entry containing data for an individual system output phase.
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
isxModularDistSysVoltagePhaseIndexmandatory
Description of each phase entry in the table.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.22.4.1.15.1.1 |
||||||
|
isxModularDistSysVoltageAlarmStatusmandatory
This is a bit map representing the active alarms for this output phase:
b0 - Minimum voltage threshold exceeded (critical) b1 - Low voltage threshold exceeded (warning) b2 - High voltage threshold exceede… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.4.1.15.1.2 |
||||||
|
isxModularDistSysVoltageLtoNmandatory
Line-to-neutral system output voltage available at the distribution panel.
Measured in tenths of Volts. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.4.1.15.1.3 |
||||||
|
isxModularDistSysVoltageLtoLmandatory
Line-to-line system output voltage available at the distribution panel.
Measured in tenths of Volts. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.4.1.15.1.4 |
.1.3.6.1.4.1.318.1.1.22.4.2.11
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk isxModularDistSysCurrentTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::isxModularDistSysCurrentTable'
Allows for getting the total system phase current information.
An entry containing data for an individual system output phase.
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
isxModularDistSysCurrentPhaseIndexmandatory
Description of each phase entry in the table.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.22.4.2.11.1.1 |
||||||
|
isxModularDistSysCurrentAlarmStatusmandatory
This is a bit map representing the active alarms for this output phase:
b0 - Minimum current threshold exceeded (critical) b1 - Low current threshold exceeded (warning) b2 - High current threshold exceede… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.4.2.11.1.2 |
||||||
|
isxModularDistSysCurrentAmpsmandatory
The current flowing though this system output phase. Measured in tenths of amps.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.4.2.11.1.3 |
||||||
|
isxModularDistSysCurrentPercentmandatory
The loading on this system output phase as a percentage of the panel current rating.
Expressed in tenths of percent. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.4.2.11.1.4 |
.1.3.6.1.4.1.318.1.1.22.4.3.5
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk isxModularDistSysPowerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::isxModularDistSysPowerTable'
Allows for getting the total system phase power loading information.
An entry containing data for an individual system output phase.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
isxModularDistSysPowerPhaseIndexmandatory
Description of each phase entry in the table.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.22.4.3.5.1.1 |
||||||
|
isxModularDistSysPowerKwmandatory
The power being supplied by this system output phase. Measured in tenths of kW.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.4.3.5.1.2 |
||||||
|
isxModularDistSysPowerKwhPhaseUsagemandatory
The energy consumed by the load equipment on this system output phase.
This is the total since the date specified in the isxModularDistSysPowerKwhResetDate OID, and may be cleared using the isxModularDistSysPowerKwhRese… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.22.4.3.5.1.3 |
.1.3.6.1.4.1.318.1.1.25.1.2
·
1 row entry
·
10 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk uioSensorStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::uioSensorStatusTable'
Allows for getting sensor status information.
The unit from which to get data.
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
uioSensorStatusPortIDmandatory
The ID of the port to which the sensor is attached.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.25.1.2.1.1 |
||||||||
|
uioSensorStatusSensorIDmandatory
The ID of the sensor.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.25.1.2.1.2 |
||||||||
|
uioSensorStatusSensorNamemandatory
The sensor name.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.25.1.2.1.3 |
||||||||
|
uioSensorStatusSensorLocationmandatory
The location of the sensor.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.25.1.2.1.4 |
||||||||
|
uioSensorStatusTemperatureDegFmandatory
The sensor's current temperature reading in degrees Fahrenheit.
-1 indicates an invalid reading due to lost communications. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.25.1.2.1.5 |
||||||||
|
uioSensorStatusTemperatureDegCmandatory
The sensor's current temperature reading in degrees Celsius.
-1 indicates an invalid reading due to lost communications. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.25.1.2.1.6 |
||||||||
|
uioSensorStatusHumiditymandatory
The sensor's current humidity reading in percent relative
humidity. -1 indicates an invalid reading due to either a sensor that doesn't read humidity or lost communications. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.25.1.2.1.7 |
||||||||
|
uioSensorStatusViolationStatusmandatory
The violation status of the sensor. This integer should be interpreted
as a bit map, with each bit representing the presence or absence of the specific alarm conditions listed below. The bit will be '1' if the conditi… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.25.1.2.1.8 |
||||||||
|
uioSensorStatusAlarmStatusmandatory
The alarm status of the sensor.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.25.1.2.1.9 |
||||||||
|
uioSensorStatusCommStatusmandatory
The communications status of the sensor.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.25.1.2.1.10 |
.1.3.6.1.4.1.318.1.1.25.1.4
·
1 row entry
·
22 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk uioSensorConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::uioSensorConfigTable'
Allows for configuring the sensor.
The sensor from which to get configuration.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
uioSensorConfigPortIDmandatory
The ID of the port to which the sensor is attached.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.25.1.4.1.1 |
||||
|
uioSensorConfigSensorIDmandatory
The ID of the sensor.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.25.1.4.1.2 |
||||
|
uioSensorConfigSensorNamemandatory
The sensor name.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.25.1.4.1.3 |
||||
|
uioSensorConfigSensorLocationmandatory
The location of the sensor.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.25.1.4.1.4 |
||||
|
The minimum (critical) temperature alarm threshold for the
probe in degrees C. Must be lower than the low threshold to ensure proper sensor alarm behavior. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.25.1.4.1.5 |
||||
|
The low (warning) temperature alarm threshold for the probe
in degrees C. Must be higher than the minimum threshold and lower than the high threshold to ensure proper sensor alarm behavior. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.25.1.4.1.6 |
||||
|
The high (warning) temperature alarm threshold for the probe
in degrees C. Must be lower than the maximum threshold and higher than the low threshold to ensure proper sensor alarm behavior. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.25.1.4.1.7 |
||||
|
The maximum (critical) temperature alarm threshold for the
probe in degrees C. Must be higher than the high threshold to ensure proper sensor alarm behavior. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.25.1.4.1.8 |
||||
|
uioSensorConfigTemperatureHysteresismandatory
The number of degrees C beyond the temperature thresholds at
which an active temperature alarm will be cleared. This value applies to all temperature thresholds. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.25.1.4.1.9 |
||||
|
uioSensorConfigMinTemperatureEnablemandatory
The minimum temperature alarm enable/disable for the sensor.
1 - disabled 2 - enabled |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.25.1.4.1.10 |
||||
|
uioSensorConfigLowTemperatureEnablemandatory
The low temperature alarm enable/disable for the sensor.
1 - disabled 2 - enabled |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.25.1.4.1.11 |
||||
|
uioSensorConfigHighTemperatureEnablemandatory
The high temperature alarm enable/disable for the sensor.
1 - disabled 2 - enabled |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.25.1.4.1.12 |
||||
|
uioSensorConfigMaxTemperatureEnablemandatory
The maximum temperature alarm enable/disable for the sensor.
1 - disabled 2 - enabled |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.25.1.4.1.13 |
||||
|
uioSensorConfigMinHumidityThresholdmandatory
The minimum (critical) humidity alarm threshold for the
probe in percent relative humidity. Must be lower than the low threshold to ensure proper sensor alarm behavior. -1 if the sensor doesn't read humidity. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.25.1.4.1.14 |
||||
|
uioSensorConfigLowHumidityThresholdmandatory
The low (warning) humidity alarm threshold for the probe in
percent relative humidity. Must be higher than the minimum threshold and lower than the high threshold to ensure proper sensor alarm behavior. -1 if the sensor… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.25.1.4.1.15 |
||||
|
uioSensorConfigHighHumidityThresholdmandatory
The high (warning) humidity alarm threshold for the probe in
percent relative humidity. Must be lower than the maximum threshold and higher than the low threshold to ensure proper sensor alarm behavior. -1 if the sensor… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.25.1.4.1.16 |
||||
|
uioSensorConfigMaxHumidityThresholdmandatory
The maximum (critical) humidity alarm threshold for the
probe in percent relative humidity. Must be higher than the high threshold to ensure proper sensor alarm behavior. -1 if the sensor doesn't read humidity. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.25.1.4.1.17 |
||||
|
uioSensorConfigHumidityHysteresismandatory
The number of percent relative humidity beyond the humidity
thresholds at which an active humidity alarm will be cleared. This value applies to all humidity thresholds. -1 if the sensor doesn't read humidity. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.25.1.4.1.18 |
||||
|
uioSensorConfigMinHumidityEnablemandatory
The minimum humidity alarm enable/disable for the sensor.
1 - disabled (always set if the sensor doesn't read humidity) 2 - enabled |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.25.1.4.1.19 |
||||
|
uioSensorConfigLowHumidityEnablemandatory
The low humidity alarm enable/disable for the sensor.
1 - disabled (always set if the sensor doesn't read humidity) 2 - enabled |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.25.1.4.1.20 |
||||
|
uioSensorConfigHighHumidityEnablemandatory
The high humidity alarm enable/disable for the sensor.
1 - disabled (always set if the sensor doesn't read humidity) 2 - enabled |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.25.1.4.1.21 |
||||
|
uioSensorConfigMaxHumidityEnablemandatory
The maximum humidity alarm enable/disable for the sensor.
1 - disabled (always set if the sensor doesn't read humidity) 2 - enabled |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.25.1.4.1.22 |
.1.3.6.1.4.1.318.1.1.25.2.2
·
1 row entry
·
7 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk uioInputContactStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::uioInputContactStatusTable'
Allows for getting input contact status information.
The input contact from which to get data.
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
uioInputContactStatusPortIDmandatory
The ID of the port to which the input contact is attached.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.25.2.2.1.1 |
||||||||
|
uioInputContactStatusContactIDmandatory
The ID of the input contact on the module.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.25.2.2.1.2 |
||||||||
|
uioInputContactStatusContactNamemandatory
The input contact name.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.25.2.2.1.3 |
||||||||
|
uioInputContactStatusContactLocationmandatory
The location of the input contact.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.25.2.2.1.4 |
||||||||
|
uioInputContactStatusCurrentStatemandatory
The current state of the input contact.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.25.2.2.1.5 |
||||||||
|
uioInputContactStatusAlarmStatusmandatory
The alarm status of the input contact.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.25.2.2.1.6 |
||||||||
|
uioInputContactStatusCommStatusmandatory
The communications status of the input contact.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.25.2.2.1.7 |
.1.3.6.1.4.1.318.1.1.25.2.4
·
1 row entry
·
7 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk uioInputContactConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::uioInputContactConfigTable'
Allows for configuring the input contacts.
The input contact from which to get configuration.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
uioInputContactConfigPortIDmandatory
The ID of the port to which the input contact is attached.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.25.2.4.1.1 |
||||
|
uioInputContactConfigContactIDmandatory
The ID of the input contact on the module.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.25.2.4.1.2 |
||||
|
uioInputContactConfigContactNamemandatory
The input contact name.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.25.2.4.1.3 |
||||
|
uioInputContactConfigContactLocationmandatory
The location of the input contact.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.25.2.4.1.4 |
||||
|
uioInputContactConfigEnablemandatory
Enable or disable this input contact.
1 - disabled 2 - enabled |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.25.2.4.1.5 |
||||
|
uioInputContactConfigNormalStatemandatory
The normal (non-alarm) state of the input contact.
1 - normally open 2 - normally closed |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.25.2.4.1.6 |
||||
|
uioInputContactConfigSeveritymandatory
The severity of the alarm that this input contact will
generate in the abnormal state. 1 - critical severity 2 - warning severity |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.25.2.4.1.7 |
.1.3.6.1.4.1.318.1.1.25.3.2
·
1 row entry
·
7 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk uioOutputRelayStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::uioOutputRelayStatusTable'
Allows for getting output relay status information.
The unit from which to get data.
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
uioOutputRelayStatusPortIDmandatory
The ID of the port to which the output relay is attached.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.25.3.2.1.1 |
||||||||
|
uioOutputRelayStatusRelayIDmandatory
The ID of the output relay on the module.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.25.3.2.1.2 |
||||||||
|
uioOutputRelayStatusRelayNamemandatory
The output relay name.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.25.3.2.1.3 |
||||||||
|
uioOutputRelayStatusRelayLocationmandatory
The location of the output relay.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.25.3.2.1.4 |
||||||||
|
uioOutputRelayStatusCurrentStatemandatory
The current state of the output relay.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.25.3.2.1.5 |
||||||||
|
uioOutputRelayStatusAlarmStatusmandatory
The alarm status of the output relay.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.25.3.2.1.6 |
||||||||
|
uioOutputRelayStatusCommStatusmandatory
The communications status of the output relay.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.25.3.2.1.7 |
.1.3.6.1.4.1.318.1.1.25.3.4
·
1 row entry
·
8 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk uioOutputRelayConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::uioOutputRelayConfigTable'
Allows for configuring the output relay.
The unit from which to get configuration.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
uioOutputRelayConfigPortIDmandatory
The ID of the port to which the output relay is attached.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.25.3.4.1.1 |
||||
|
uioOutputRelayConfigRelayIDmandatory
The ID of the output relay on the module.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.25.3.4.1.2 |
||||
|
uioOutputRelayConfigRelayNamemandatory
The output relay name.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.25.3.4.1.3 |
||||
|
uioOutputRelayConfigRelayLocationmandatory
The location of the output relay.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.25.3.4.1.4 |
||||
|
uioOutputRelayConfigNormalStatemandatory
The normal state of the output relay.
1 - normally open 2 - normally closed |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.25.3.4.1.5 |
||||
|
uioOutputRelayConfigControlStatemandatory
Close or open the output relay for testing purposes. Always
returns 1 when read. 1 - close output relay 2 - open output relay |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.25.3.4.1.6 |
||||
|
uioOutputRelayConfigDelaymandatory
The time a selected alarm condition must exist before the
output relay is activated. Valid values are whole seconds from 0 to 65535. |
RFC1155-SMITimeTicksr/w Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.318.1.1.25.3.4.1.7 |
||||
|
uioOutputRelayConfigHoldmandatory
The minimum time the output relay remains activated after the
alarm occurs. Valid values are whole seconds from 0 to 65535. |
RFC1155-SMITimeTicksr/w Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.318.1.1.25.3.4.1.8 |
.1.3.6.1.4.1.318.1.1.25.4.2
·
1 row entry
·
7 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk uioSpotFluidSensorStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::uioSpotFluidSensorStatusTable'
Allows for getting fluid sensor status information.
The unit from which to get data.
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
uioSpotFluidSensorStatusPortIDmandatory
The ID of the port to which the fluid sensor is attached.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.25.4.2.1.1 |
||||||||
|
uioSpotFluidSensorStatusSensorIDmandatory
The ID of the fluid sensor on the module.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.25.4.2.1.2 |
||||||||
|
uioSpotFluidSensorStatusSensorNamemandatory
The fluid sensor name.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.25.4.2.1.3 |
||||||||
|
The location of the fluid sensor.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.25.4.2.1.4 |
||||||||
|
uioSpotFluidSensorStatusCurrentStatemandatory
The current state of the fluid sensor.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.25.4.2.1.5 |
||||||||
|
uioSpotFluidSensorStatusAlarmStatusmandatory
The alarm status of the fluid sensor.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.25.4.2.1.6 |
||||||||
|
uioSpotFluidSensorStatusCommStatusmandatory
The communications status of the fluid sensor.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.25.4.2.1.7 |
.1.3.6.1.4.1.318.1.1.25.4.4
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk uioSpotFluidSensorConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::uioSpotFluidSensorConfigTable'
Allows for configuring the fluid sensor.
The unit from which to get configuration.
| Column | Syntax | OID |
|---|---|---|
|
uioSpotFluidSensorConfigPortIDmandatory
The ID of the port to which the fluid sensor is attached.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.25.4.4.1.1 |
|
uioSpotFluidSensorConfigSensorIDmandatory
The ID of the fluid sensor on the module.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.25.4.4.1.2 |
|
uioSpotFluidSensorConfigSensorNamemandatory
The fluid sensor name.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.25.4.4.1.3 |
|
The location of the fluid sensor.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.25.4.4.1.4 |
.1.3.6.1.4.1.318.1.1.26.2
·
1 row entry
·
16 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDU2IdentTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDU2IdentTable'
A table of Rack PDU identification data
Identification data from Rack PDU being queried
Indexes
| Column | Syntax | OID |
|---|---|---|
|
rPDU2IdentIndexmandatory
The index to the Rack PDU identification table
entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.2.1.1 |
|
rPDU2IdentModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.2.1.2 |
|
rPDU2IdentNamemandatory
A user-defined string identifying the Rack PDU
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.2.1.3 |
|
rPDU2IdentLocationmandatory
A user-defined string identifying the location
of the Rack PDU |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.2.1.4 |
|
rPDU2IdentHardwareRevmandatory
The Rack PDU hardware version
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.2.1.5 |
|
rPDU2IdentFirmwareRevmandatory
The Rack PDU firmware version
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.2.1.6 |
|
rPDU2IdentDateOfManufacturemandatory
The date the Rack PDU was manufactured
in mm/dd/yyyy format |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.2.1.7 |
|
rPDU2IdentModelNumbermandatory
The Rack PDU model number
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.2.1.8 |
|
rPDU2IdentSerialNumbermandatory
The Rack PDU serial number
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.2.1.9 |
|
rPDU2IdentContactmandatory
A user-defined string identifying the
person to contact regarding the Rack PDU |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.2.1.10 |
|
rPDU2IdentBootMonitorRevmandatory
The Rack PDU Boot Monitor version
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.2.1.11 |
|
rPDU2IdentLongDescriptionmandatory
The Rack PDU Long Description name
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.2.1.12 |
|
rPDU2IdentNMCSerialNumbermandatory
The Rack PDU Network Management Card (NMC) serial number
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.2.1.13 |
|
rPDU2IndentAppBuildDatemandatory
The Rack PDU Application build date
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.2.1.14 |
|
rPDU2IndentAOSBuildDatemandatory
The Rack PDU AOS build date
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.2.1.15 |
|
rPDU2IndentBootMonBuildDatemandatory
The Rack PDU Boot Monitor build date
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.2.1.16 |
.1.3.6.1.4.1.318.1.1.26.4.1
·
1 row entry
·
14 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDU2DeviceConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDU2DeviceConfigTable'
A table of Rack PDU configuration data
Configuration data from Rack PDU being queried
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
rPDU2DeviceConfigIndexmandatory
The index to the Rack PDU table entry
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.4.1.1.1 |
||||||
|
rPDU2DeviceConfigModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.4.1.1.2 |
||||||
|
rPDU2DeviceConfigNamemandatory
A user-defined string identifying the Rack PDU
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.26.4.1.1.3 |
||||||
|
rPDU2DeviceConfigLocationmandatory
A user-defined string identifying the location
of the Rack PDU |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.26.4.1.1.4 |
||||||
|
rPDU2DeviceConfigDisplayOrientationmandatory
Indicates the intended physical orientation
of the display. displayNormal(1) indicates normal orientation displayReverse(2) indicates upside down orientation |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.4.1.1.5 |
||||||
|
rPDU2DeviceConfigColdstartDelaymandatory
The amount of delay, measured in seconds, between
when power is provided to the Rack PDU and when the Rack PDU provides basic master power to the outlets. Allowed values are: -1 - never apply power automatically. … |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.4.1.1.6 |
||||||
|
User-defined low power draw alarm threshold,
measured in tenths of kilowatts. Models that do not support this feature will respond to this OID with a value of -1. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.4.1.1.7 |
||||||
|
User-defined near power overload threshold,
measured in tenths of kilowatts. Models that do not support this feature will respond to this OID with a value of -1. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.4.1.1.8 |
||||||
|
User-defined power overload threshold,
measured in tenths of kilowatts. Models that do not support this feature will respond to this OID with a value of -1. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.4.1.1.9 |
||||||
|
Setting this OID to reset (2) will cause the existing peak power value
to be replaced by the current load power value. Getting this OID will do nothing and return the noOperation(1) value. Models that do … |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.4.1.1.10 |
||||||
|
rPDU2DeviceConfigDeviceEnergyResetmandatory
Setting this OID to reset (2) will cause the device energy meter value
to be reset to zero. Getting this OID in models that support this feature will do nothing and return the noOperation(1) value. … |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.4.1.1.11 |
||||||
|
rPDU2DeviceConfigOutletsEnergyResetmandatory
Setting this OID to reset (2) will cause the all outlet energy meter values
to be reset to zero. Getting this OID will do nothing and return the noOperation(1) value. Models that do not sup… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.4.1.1.12 |
||||||
|
Setting this OID to reset (2) will cause the all outlet peak load values
to be reset to zero. Getting this OID will do nothing and return the noOperation(1) value. Models that do not suppor… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.4.1.1.13 |
||||||
|
rPDU2DeviceConfigContactmandatory
A user-defined string identifying the
person to contact regarding the Rack PDU |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.26.4.1.1.14 |
.1.3.6.1.4.1.318.1.1.26.4.2
·
1 row entry
·
13 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDU2DevicePropertiesTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDU2DevicePropertiesTable'
A table of Rack PDU properties
Properties of the Rack PDU being queried
Indexes
| Column | Syntax | OID | ||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
rPDU2DevicePropertiesIndexmandatory
The index to the Rack PDU properties table entry
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.4.2.1.1 |
||||||||||||||||||||
|
rPDU2DevicePropertiesModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.4.2.1.2 |
||||||||||||||||||||
|
rPDU2DevicePropertiesNamemandatory
A user-defined string identifying the Rack PDU
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.4.2.1.3 |
||||||||||||||||||||
|
rPDU2DevicePropertiesNumOutletsmandatory
The number of outlets on the Rack PDU
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.4.2.1.4 |
||||||||||||||||||||
|
The number of switched outlets on the Rack PDU
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.4.2.1.5 |
||||||||||||||||||||
|
The number of metered outlets on the Rack PDU
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.4.2.1.6 |
||||||||||||||||||||
|
rPDU2DevicePropertiesNumPhasesmandatory
The number of phases present in the Rack PDU
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.4.2.1.7 |
||||||||||||||||||||
|
rPDU2DevicePropertiesNumMeteredBanksmandatory
The number of metered banks present in the Rack PDU
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.4.2.1.8 |
||||||||||||||||||||
|
The maximum current rating, measured in Amps, for
the Rack PDU |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.4.2.1.9 |
||||||||||||||||||||
|
rPDU2DevicePropertiesOrientationmandatory
Rack PDU orientation
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.4.2.1.10 |
||||||||||||||||||||
|
rPDU2DevicePropertiesOutletLayoutmandatory
Getting this OID will return outlet layout for the device.
seqPhaseToNeutral(1) indicates outlet layout as follows: 1:1-N,2:2-N,3:3-N,4:1-N,5:2-N,... or for single phase SKUs, all outlets 1-N … |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.4.2.1.11 |
||||||||||||||||||||
|
The maximum current rating, measured in Amps, for
the Rack PDU |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.4.2.1.12 |
||||||||||||||||||||
|
The maximum power rating, measured in tenths of kilowatts, for
the Rack PDU |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.4.2.1.13 |
.1.3.6.1.4.1.318.1.1.26.4.3
·
1 row entry
·
18 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDU2DeviceStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDU2DeviceStatusTable'
A table of Rack PDU status information
Status information from the Rack PDU being queried
Indexes
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
rPDU2DeviceStatusIndexmandatory
The index to the Rack PDU status table entry
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.4.3.1.1 |
||||||||||
|
rPDU2DeviceStatusModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.4.3.1.2 |
||||||||||
|
rPDU2DeviceStatusNamemandatory
A user-defined string identifying the Rack PDU
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.4.3.1.3 |
||||||||||
|
rPDU2DeviceStatusLoadStatemandatory
Indicates the present load status of the Rack PDU.
Models that do not support this feature will respond to this OID with a value of notsupported (5). |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.4.3.1.4 |
||||||||||
|
rPDU2DeviceStatusPowermandatory
The power consumption of the Rack PDU load in hundredths of kilowatts.
Models that do not support this feature will respond to this OID with a value of -1. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.4.3.1.5 |
||||||||||
|
rPDU2DeviceStatusPeakPowermandatory
The peak power consumption of the Rack PDU load in hundredths of kilowatts.
Models that do not support this feature will respond to this OID with a value of -1. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.4.3.1.6 |
||||||||||
|
rPDU2DeviceStatusPeakPowerTimestampmandatory
Indicates the date and time that peak power consumption occurred.
Models that do not support this feature will respond to this OID with string 'notsupported'. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.4.3.1.7 |
||||||||||
|
rPDU2DeviceStatusPeakPowerStartTimemandatory
Indicates the date and time of the last device peak power reset.
Models that do not support this feature will respond to this OID with string 'notsupported'. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.4.3.1.8 |
||||||||||
|
rPDU2DeviceStatusEnergymandatory
A user resettable energy meter measuring Rack PDU load
energy consumption in tenths of kilowatt-hours. Models that do not support this feature will respond to this OID with a value of -1. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.4.3.1.9 |
||||||||||
|
rPDU2DeviceStatusEnergyStartTimemandatory
Indicates the date and time of the last device energy
meter reset. Models that do not support this feature will respond to this OID with string 'notsupported'. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.4.3.1.10 |
||||||||||
|
rPDU2DeviceStatusCommandPendingmandatory
Indicates whether or not the device
is processing a pending command. If the commandPendingUnknown (3) value is returned, all devices powered by the Rack PDU should be shut down. The Rack PDU's power should then be cyc… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.4.3.1.11 |
||||||||||
|
rPDU2DeviceStatusPowerSupplyAlarmmandatory
Indicates a power supply alarm is active when value
equals alarm (2) |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.4.3.1.12 |
||||||||||
|
rPDU2DeviceStatusPowerSupply1Statusmandatory
Indicates whether or not an alarm is active in Power
Supply 1 |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.4.3.1.13 |
||||||||||
|
rPDU2DeviceStatusPowerSupply2Statusmandatory
Indicates whether or not an alarm is active in Power
Supply 2 |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.4.3.1.14 |
||||||||||
|
Indicates the date and time of the last outlets energy
meter reset. Models that do not support this feature will respond to this OID with string 'notsupported'. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.4.3.1.15 |
||||||||||
|
rPDU2DeviceStatusApparentPowermandatory
The apparent power consumption of the Rack PDU load in hundredths of kiloVoltAmps (kVA).
Models that do not support this feature will respond to this OID with a value of -1. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.4.3.1.16 |
||||||||||
|
rPDU2DeviceStatusPowerFactormandatory
The power factor of the Rack PDU load in hundredths. Models that do not support this feature
will respond to this OID with a value of -1. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.4.3.1.17 |
||||||||||
|
rPDU2DeviceStatusNPSTypemandatory
The device NPS status:
notNPS (1) indicates the Rack PDU is not in an NPS group. host (2) indicates the Rack PDU has been designated as a host in an NPS group. Only one Rack PDU in an NPS group is allowed to be the ho… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.4.3.1.18 |
.1.3.6.1.4.1.318.1.1.26.4.4
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDU2DeviceControlTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDU2DeviceControlTable'
A table of Rack PDU control data
Control data from Rack PDU being queried
Indexes
| Column | Syntax | OID | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
rPDU2DeviceControlIndexmandatory
The index to the Rack PDU control table entry
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.4.4.1.1 |
||||||||||||||||
|
rPDU2DeviceControlModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.4.4.1.2 |
||||||||||||||||
|
rPDU2DeviceControlNamemandatory
A user-defined string identifying the Rack PDU
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.4.4.1.3 |
||||||||||||||||
|
rPDU2DeviceControlCommandmandatory
Setting this OID to immediateAllOn (1) will turn all outlets
on immediately. Setting this OID to delayedAllOn (2) will turn all outlets on as defined by each outlet's rPDU2OutletSwitchedConfigPowerOnTime … |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.4.4.1.4 |
.1.3.6.1.4.1.318.1.1.26.6.1
·
1 row entry
·
8 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDU2PhaseConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDU2PhaseConfigTable'
A table of Rack PDU phase configuration data
Configuration data from currently queried Rack
PDU phase
PDU phase
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
rPDU2PhaseConfigIndexmandatory
The index to the Rack PDU phase configuration
table entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.6.1.1.1 |
||||||||
|
rPDU2PhaseConfigModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.6.1.1.2 |
||||||||
|
rPDU2PhaseConfigNumbermandatory
The numeric phase ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.6.1.1.3 |
||||||||
|
rPDU2PhaseConfigOverloadRestrictionmandatory
This OID controls the behavior of a Switched Rack PDU
phase when an overload condition is possible and additional outlets are requested to be turned on. Setting this OID to alwaysAllowTurnON (1) will alwa… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.6.1.1.4 |
||||||||
|
User-defined low load phase current
threshold in Amps |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.6.1.1.5 |
||||||||
|
User-defined near phase overload warning
threshold in Amps |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.6.1.1.6 |
||||||||
|
User-defined phase overload current
threshold in Amps |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.6.1.1.7 |
||||||||
|
Setting this OID to reset (2) will cause the existing peak current value
to be replaced by the present load current value. Getting this OID will do nothing and return the noOperation(1) value. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.6.1.1.8 |
.1.3.6.1.4.1.318.1.1.26.6.2
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDU2PhasePropertiesTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDU2PhasePropertiesTable'
A table of Rack PDU phase properties
Properties of the currently queried Rack
PDU phase
PDU phase
Indexes
| Column | Syntax | OID |
|---|---|---|
|
rPDU2PhasePropertiesIndexmandatory
The index to the Rack PDU phase properties
table entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.6.2.1.1 |
|
rPDU2PhasePropertiesModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.6.2.1.2 |
|
rPDU2PhasePropertiesNumbermandatory
The numeric phase ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.6.2.1.3 |
.1.3.6.1.4.1.318.1.1.26.6.3
·
1 row entry
·
12 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDU2PhaseStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDU2PhaseStatusTable'
A table of Rack PDU phase status data
Status data from currently queried Rack PDU
phase
phase
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
rPDU2PhaseStatusIndexmandatory
The index to the Rack PDU phase status table
entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.6.3.1.1 |
||||||||
|
rPDU2PhaseStatusModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.6.3.1.2 |
||||||||
|
rPDU2PhaseStatusNumbermandatory
The numeric phase ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.6.3.1.3 |
||||||||
|
rPDU2PhaseStatusLoadStatemandatory
Indicates the present load status of the Rack PDU
phase being queried |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.6.3.1.4 |
||||||||
|
rPDU2PhaseStatusCurrentmandatory
Indicates the current draw, in tenths of Amps, of the load
on the Rack PDU phase being queried |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.6.3.1.5 |
||||||||
|
rPDU2PhaseStatusVoltagemandatory
Indicates the Voltage, in Volts, of the Rack
PDU phase being queried. Models that do not support this feature will respond to this OID with a value of -1. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.6.3.1.6 |
||||||||
|
rPDU2PhaseStatusPowermandatory
Indicates the load power, in hundredths of kilowatts (kW),
consumed on the Rack PDU phase being queried. Models that do not support this feature will respond to this OID with a value of -1. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.6.3.1.7 |
||||||||
|
rPDU2PhaseStatusApparentPowermandatory
Indicates the load apparent power, in hundredths of kiloVoltAmps (kVA),
consumed on the Rack PDU phase being queried. Models that do not support this feature will respond to this OID with a value of -1. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.6.3.1.8 |
||||||||
|
rPDU2PhaseStatusPowerFactormandatory
Indicates the load power factor, in hundredths,
of the Rack PDU phase being queried. Models that do not support this feature will respond to this OID with a value of -1. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.6.3.1.9 |
||||||||
|
rPDU2PhaseStatusPeakCurrentmandatory
The peak current of the Rack PDU phase load in tenths of Amps
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.6.3.1.10 |
||||||||
|
rPDU2PhaseStatusPeakCurrentTimestampmandatory
Indicates the date and time that the peak current occurred
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.6.3.1.11 |
||||||||
|
rPDU2PhaseStatusPeakCurrentStartTimemandatory
Indicates the date and time of the last phase peak current reset
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.6.3.1.12 |
.1.3.6.1.4.1.318.1.1.26.8.1
·
1 row entry
·
8 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDU2BankConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDU2BankConfigTable'
A table of Rack PDU bank configuration data
Configuration data from currently queried
Rack PDU bank
Rack PDU bank
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
rPDU2BankConfigIndexmandatory
The index to the Rack PDU bank configuration
table entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.8.1.1.1 |
||||||||
|
rPDU2BankConfigModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.8.1.1.2 |
||||||||
|
rPDU2BankConfigNumbermandatory
The numeric bank ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.8.1.1.3 |
||||||||
|
rPDU2BankConfigOverloadRestrictionmandatory
This OID controls the behavior of a Switched Rack PDU
bank when an overload condition is possible and additional outlets are requested to be turned on. Setting this OID to alwaysAllowTurnON (1) will alway… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.8.1.1.4 |
||||||||
|
User-defined low load bank current
threshold in Amps |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.8.1.1.5 |
||||||||
|
User-defined near bank overload current warning
threshold in Amps |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.8.1.1.6 |
||||||||
|
User-defined bank overload current threshold
in Amps |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.8.1.1.7 |
||||||||
|
rPDU2BankConfigBankPeakCurrentResetmandatory
Setting this OID to reset (2) will cause the existing peak current value
to be replaced by the present load current value. Getting this OID will do nothing and return the noOperation(1) value. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.8.1.1.8 |
.1.3.6.1.4.1.318.1.1.26.8.2
·
1 row entry
·
5 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDU2BankPropertiesTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDU2BankPropertiesTable'
A table of Rack PDU bank properties
Properties of the currently queried
Rack PDU bank
Rack PDU bank
Indexes
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
rPDU2BankPropertiesIndexmandatory
The index to the Rack PDU bank properties
table entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.8.2.1.1 |
||||||||||||
|
rPDU2BankPropertiesModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.8.2.1.2 |
||||||||||||
|
rPDU2BankPropertiesNumbermandatory
The numeric bank ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.8.2.1.3 |
||||||||||||
|
rPDU2BankPropertiesPhaseLayoutmandatory
This OID describes the outlet phase connections on
the referenced bank as follows: seqPhase1ToNeutral(1) indicates that bank outlets are wired from Phase 1 to Neutral. seqPhase2ToNeutral(2)… |
Rpdu2OutletPhaseLayoutType Type Values:
|
.1.3.6.1.4.1.318.1.1.26.8.2.1.4 |
||||||||||||
|
rPDU2BankPropertiesBreakerRatingmandatory
If bank circuit breakers are present on the device, this OID will return
the rating of the breaker in Amps. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.8.2.1.5 |
.1.3.6.1.4.1.318.1.1.26.8.3
·
1 row entry
·
8 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDU2BankStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDU2BankStatusTable'
A table of Rack PDU bank status data
Status data from currently queried Rack PDU
bank
bank
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
rPDU2BankStatusIndexmandatory
The index to the Rack PDU bank status
table entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.8.3.1.1 |
||||||||
|
rPDU2BankStatusModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.8.3.1.2 |
||||||||
|
rPDU2BankStatusNumbermandatory
The numeric bank ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.8.3.1.3 |
||||||||
|
rPDU2BankStatusLoadStatemandatory
Indicates the present load status of the Rack PDU
bank being queried |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.8.3.1.4 |
||||||||
|
rPDU2BankStatusCurrentmandatory
Indicates the current draw, in tenths of Amps, of the load
on the Rack PDU bank being queried |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.8.3.1.5 |
||||||||
|
rPDU2BankStatusPeakCurrentmandatory
The peak current of the Rack PDU bank load in tenths of Amps
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.8.3.1.6 |
||||||||
|
rPDU2BankStatusPeakCurrentTimestampmandatory
Indicates the date and time the bank peak current occurred
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.8.3.1.7 |
||||||||
|
rPDU2BankStatusPeakCurrentStartTimemandatory
Indicates the date and time of the last bank peak current reset
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.8.3.1.8 |
.1.3.6.1.4.1.318.1.1.26.9.2.1
·
1 row entry
·
8 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDU2OutletSwitchedConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDU2OutletSwitchedConfigTable'
A table of Rack PDU switched outlet configuration data
Configuration data from currently queried
Rack PDU switched outlet
Rack PDU switched outlet
Indexes
| Column | Syntax | OID |
|---|---|---|
|
rPDU2OutletSwitchedConfigIndexmandatory
The index to the Rack PDU switched outlet
configuration table entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.9.2.1.1.1 |
|
rPDU2OutletSwitchedConfigModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.9.2.1.1.2 |
|
rPDU2OutletSwitchedConfigNamemandatory
The user-defined switched outlet ID string
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.26.9.2.1.1.3 |
|
rPDU2OutletSwitchedConfigNumbermandatory
The numeric switched outlet ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.9.2.1.1.4 |
|
rPDU2OutletSwitchedConfigPowerOnTimemandatory
The amount of delay, in seconds, between when
power is provided to the Rack PDU and when this switched outlet starts providing power. Range -1...7200 where -1 = Never power on, 0 = immediate power on, and 1-7200 = secon… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.9.2.1.1.5 |
|
The amount of time, in seconds, this outlet will
delay powering off. Range -1...7200 where -1 = Never power off, 0 = immediate power off, and 1-7200 = seconds to delay. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.9.2.1.1.6 |
|
After turning power off during a reboot sequence,
the amount of time to wait before turning power to this outlet back on. Range 5-60 seconds delay. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.9.2.1.1.7 |
|
User-defined external device web link.
Possible use cases could be the IP address of the external device plugged into the outlet or its manufacturer web page for convenient support such as user manuals, specifications… |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.26.9.2.1.1.8 |
.1.3.6.1.4.1.318.1.1.26.9.2.2
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDU2OutletSwitchedPropertiesTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDU2OutletSwitchedPropertiesTable'
A table of Rack PDU switched outlet properties
Properties of the currently queried Rack PDU
switched outlet
switched outlet
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
rPDU2OutletSwitchedPropertiesIndexmandatory
The index to the Rack PDU switched outlet
properties table entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.9.2.2.1.1 |
||||||||||||
|
rPDU2OutletSwitchedPropertiesModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.9.2.2.1.2 |
||||||||||||
|
rPDU2OutletSwitchedPropertiesNamemandatory
The user-defined switched outlet ID string
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.9.2.2.1.3 |
||||||||||||
|
rPDU2OutletSwitchedPropertiesNumbermandatory
The numeric switched outlet ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.9.2.2.1.4 |
||||||||||||
|
This OID describes the phase connections of
the referenced outlet as follows: seqPhase1ToNeutral(1) indicates that the outlet is wired from Phase 1 to Neutral. seqPhase2ToNeutral(2) indicat… |
Rpdu2OutletPhaseLayoutType Type Values:
|
.1.3.6.1.4.1.318.1.1.26.9.2.2.1.5 |
||||||||||||
|
rPDU2OutletSwitchedPropertiesBankmandatory
The numeric bank ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.9.2.2.1.6 |
.1.3.6.1.4.1.318.1.1.26.9.2.3
·
1 row entry
·
7 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDU2OutletSwitchedStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDU2OutletSwitchedStatusTable'
A table of Rack PDU switched outlet status information
Status information for currently queried
Rack PDU switched outlet
Rack PDU switched outlet
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
rPDU2OutletSwitchedStatusIndexmandatory
The index to the Rack PDU switched outlet
status information table entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.9.2.3.1.1 |
||||||
|
rPDU2OutletSwitchedStatusModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.9.2.3.1.2 |
||||||
|
rPDU2OutletSwitchedStatusNamemandatory
The user-defined switched outlet ID string
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.9.2.3.1.3 |
||||||
|
rPDU2OutletSwitchedStatusNumbermandatory
The numeric switched outlet ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.9.2.3.1.4 |
||||||
|
rPDU2OutletSwitchedStatusStatemandatory
Indicates the present switch state of the Rack
PDU switched outlet being queried |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.9.2.3.1.5 |
||||||
|
Indicates whether or not the device is
processing a command for this outlet. If the commandPendingUnknown (3) value is returned, all devices powered by the Rack PDU should be shut down. The Rack PDU's po… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.9.2.3.1.6 |
||||||
|
Each RPDU outlet can have its own external web URL link.
This can be configured in the rPDU2OutletSwitchedConfigExternalLink OID. When this link is clicked in the web interface, the linked URL will open in the web b… |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.9.2.3.1.7 |
.1.3.6.1.4.1.318.1.1.26.9.2.4
·
1 row entry
·
5 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDU2OutletSwitchedControlTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDU2OutletSwitchedControlTable'
A table of Rack PDU switched outlet control data
Control data for currently queried Rack
PDU switched outlet
PDU switched outlet
Indexes
| Column | Syntax | OID | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
rPDU2OutletSwitchedControlIndexmandatory
The index to the Rack PDU switched outlet
control data table entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.9.2.4.1.1 |
||||||||||||||||
|
rPDU2OutletSwitchedControlModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.9.2.4.1.2 |
||||||||||||||||
|
rPDU2OutletSwitchedControlNamemandatory
The user-defined switched outlet ID string
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.9.2.4.1.3 |
||||||||||||||||
|
rPDU2OutletSwitchedControlNumbermandatory
The numeric switched outlet ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.9.2.4.1.4 |
||||||||||||||||
|
rPDU2OutletSwitchedControlCommandmandatory
Getting this variable will return the outlet state. If
the outlet is on, the immediateOn (1) value will be returned. If the outlet is off, the immediateOff (2) value will be returned. If the state of the outlet cannot b… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.9.2.4.1.5 |
.1.3.6.1.4.1.318.1.1.26.9.4.1
·
1 row entry
·
8 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDU2OutletMeteredConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDU2OutletMeteredConfigTable'
A table of Rack PDU metered outlet configuration data
Configuration data from currently queried
Rack PDU metered outlet
Rack PDU metered outlet
Indexes
| Column | Syntax | OID |
|---|---|---|
|
rPDU2OutletMeteredConfigIndexmandatory
The index to the Rack PDU metered outlet
configuration table entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.9.4.1.1.1 |
|
rPDU2OutletMeteredConfigModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.9.4.1.1.2 |
|
rPDU2OutletMeteredConfigNamemandatory
The user-defined metered outlet ID string
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.26.9.4.1.1.3 |
|
rPDU2OutletMeteredConfigNumbermandatory
The numeric switched outlet ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.9.4.1.1.4 |
|
User-defined low load outlet current threshold in Watts
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.9.4.1.1.5 |
|
User-defined near outlet overload warning threshold
in Watts |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.9.4.1.1.6 |
|
User-defined outlet overload current threshold in Watts
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.9.4.1.1.7 |
|
rPDU2OutletMeteredConfigExternalLinkmandatory
User-defined external device web link.
Possible use cases could be the IP address of the external device plugged into the outlet or its manufacturer web page for convenient support such as user manuals, specifications… |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.26.9.4.1.1.8 |
.1.3.6.1.4.1.318.1.1.26.9.4.2
·
1 row entry
·
7 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDU2OutletMeteredPropertiesTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDU2OutletMeteredPropertiesTable'
A table of Rack PDU metered outlet properties
Properties of currently queried Rack PDU
metered outlet
metered outlet
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
rPDU2OutletMeteredPropertiesIndexmandatory
The index to the Rack PDU metered properties table
entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.9.4.2.1.1 |
||||||||||||
|
rPDU2OutletMeteredPropertiesModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.9.4.2.1.2 |
||||||||||||
|
rPDU2OutletMeteredPropertiesNamemandatory
The user-defined metered outlet ID string
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.9.4.2.1.3 |
||||||||||||
|
rPDU2OutletMeteredPropertiesNumbermandatory
The numeric metered outlet ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.9.4.2.1.4 |
||||||||||||
|
rPDU2OutletMeteredPropertiesLayoutmandatory
This OID describes the phase connections of
the referenced outlet as follows: seqPhase1ToNeutral(1) indicates that the outlet is wired from Phase 1 to Neutral. seqPhase2ToNeutral(2) indicat… |
Rpdu2OutletPhaseLayoutType Type Values:
|
.1.3.6.1.4.1.318.1.1.26.9.4.2.1.5 |
||||||||||||
|
Maximum power rating of Rack PDU metered outlet
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.9.4.2.1.6 |
||||||||||||
|
rPDU2OutletMeteredPropertiesBankmandatory
This outlet's numeric bank ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.9.4.2.1.7 |
.1.3.6.1.4.1.318.1.1.26.9.4.3
·
1 row entry
·
13 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDU2OutletMeteredStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDU2OutletMeteredStatusTable'
A table of Rack PDU metered outlet status data
Status data from currently queried Rack PDU
metered outlet
metered outlet
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
rPDU2OutletMeteredStatusIndexmandatory
The index to the Rack PDU metered status table
entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.9.4.3.1.1 |
||||||||
|
rPDU2OutletMeteredStatusModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.9.4.3.1.2 |
||||||||
|
rPDU2OutletMeteredStatusNamemandatory
The user-defined metered outlet ID string
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.9.4.3.1.3 |
||||||||
|
rPDU2OutletMeteredStatusNumbermandatory
The numeric metered outlet ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.9.4.3.1.4 |
||||||||
|
rPDU2OutletMeteredStatusStatemandatory
Indicates the present load status of the Rack
PDU metered outlet being queried |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.9.4.3.1.5 |
||||||||
|
rPDU2OutletMeteredStatusCurrentmandatory
Indicates the current draw, in tenths
of Amps, of the load on the Rack PDU outlet being queried |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.9.4.3.1.6 |
||||||||
|
rPDU2OutletMeteredStatusPowermandatory
Indicates the power draw of the load
on the Rack PDU outlet being queried |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.9.4.3.1.7 |
||||||||
|
rPDU2OutletMeteredStatusPeakPowermandatory
Indicates the peak power load draw
on the Rack PDU outlet being queried |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.9.4.3.1.8 |
||||||||
|
Indicates the date and time that this metered
outlet's peak power consumption occurred |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.9.4.3.1.9 |
||||||||
|
Indicates the start date and time that this metered
outlet began recording peak power observations |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.9.4.3.1.10 |
||||||||
|
rPDU2OutletMeteredStatusEnergymandatory
A user resettable energy meter measuring Rack PDU load
energy consumption in tenths of kilowatt-hours |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.9.4.3.1.11 |
||||||||
|
Indicates receptacle type for the outlet.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.9.4.3.1.12 |
||||||||
|
rPDU2OutletMeteredStatusExternalLinkmandatory
Each RPDU outlet can have its own external web URL link.
This can be configured in the rPDU2OutletMeteredConfigExternalLink OID. When this link is clicked in the web interface, the linked URL will open in the web br… |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.9.4.3.1.13 |
.1.3.6.1.4.1.318.1.1.26.10.2.1
·
1 row entry
·
16 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDU2SensorTempHumidityConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDU2SensorTempHumidityConfigTable'
A table of temperature-humidity sensor configuration data
Configuration data from temperature-humidity sensor
being queried
being queried
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
rPDU2SensorTempHumidityConfigIndexmandatory
The index to the temperature-humidity sensor
configuration data table entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.10.2.1.1.1 |
||||
|
rPDU2SensorTempHumidityConfigModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.10.2.1.1.2 |
||||
|
rPDU2SensorTempHumidityConfigNamemandatory
The user-defined temperature-humidity
sensor ID string |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.26.10.2.1.1.3 |
||||
|
rPDU2SensorTempHumidityConfigNumbermandatory
The temperature-humidity sensor numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.10.2.1.1.4 |
||||
|
Setting this OID enables or disables generation
of sensor temperature alarm. Getting this OID returns the current value of the temperature alarm enable. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.10.2.1.1.5 |
||||
|
Setting this OID enables or disables generation
of sensor humidity alarm. Getting this OID returns the current value of the humidity alarm enable. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.10.2.1.1.6 |
||||
|
Sensor maximum temperature alarm threshold in
Fahrenheit. Attempting to set this OID to a value less than or equal to that of rPDU2SensorTempHumidityConfigTempHighThreshF will result in an error. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.10.2.1.1.7 |
||||
|
Sensor high temperature warning alarm threshold
in Fahrenheit. Attempting to set this OID to a value greater than or equal to that of rPDU2SensorTempHumidityConfigTempMaxThreshF will result in an error. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.10.2.1.1.8 |
||||
|
Sensor temperature hysteresis setting in Fahrenheit
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.10.2.1.1.9 |
||||
|
Sensor maximum temperature alarm threshold
in Celsius. Attempting to set this OID to a value less than or equal to that of rPDU2SensorTempHumidityConfigTempHighThreshC will result in an error. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.10.2.1.1.10 |
||||
|
Sensor high temperature warning alarm threshold
in Celsius. Attempting to set this OID to a value greater than or equal to that of rPDU2SensorTempHumidityConfigTempMaxThreshC will result in an error. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.10.2.1.1.11 |
||||
|
Sensor temperature hysteresis setting in Celsius
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.10.2.1.1.12 |
||||
|
Sensor low humidity warning alarm threshold in
percent relative humidity. May be 10% to 90%, but must be greater than rPDU2SensorTempHumidityConfigHumidityMinThresh. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.10.2.1.1.13 |
||||
|
Sensor minimum humidity alarm threshold in
percent relative humidity. May be 10% to 90%, but must be less than rPDU2SensorTempHumidityConfigHumidityLowThresh. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.10.2.1.1.14 |
||||
|
Sensor humidity hysteresis setting in percent relative
humidity |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.10.2.1.1.15 |
||||
|
Setting this OID to reset (2) will cause the existing peak temperature
to be replaced by the present temperature reading. Getting this OID will do nothing and return the noOperation(1) value. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.10.2.1.1.16 |
.1.3.6.1.4.1.318.1.1.26.10.2.2
·
1 row entry
·
15 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDU2SensorTempHumidityStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDU2SensorTempHumidityStatusTable'
A table of temperature-humidity sensor status data
Status information from temperature-humidity sensor
being queried
being queried
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
rPDU2SensorTempHumidityStatusIndexmandatory
The index to the temperature-humidity
status data table entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.10.2.2.1.1 |
||||||||||||
|
rPDU2SensorTempHumidityStatusModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.10.2.2.1.2 |
||||||||||||
|
rPDU2SensorTempHumidityStatusNamemandatory
The user-defined temperature-humidity
sensor ID string |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.10.2.2.1.3 |
||||||||||||
|
rPDU2SensorTempHumidityStatusNumbermandatory
The temperature-humidity sensor numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.10.2.2.1.4 |
||||||||||||
|
rPDU2SensorTempHumidityStatusTypemandatory
The type of the sensor
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.10.2.2.1.5 |
||||||||||||
|
The communications status of the sensor
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.10.2.2.1.6 |
||||||||||||
|
rPDU2SensorTempHumidityStatusTempFmandatory
Sensor temperature reading in tenths of degrees Fahrenheit
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.10.2.2.1.7 |
||||||||||||
|
rPDU2SensorTempHumidityStatusTempCmandatory
Sensor temperature reading in tenths of degrees Celsius
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.10.2.2.1.8 |
||||||||||||
|
This OID reports the current state of the temperature probe.
A notPresent (1) response indicates that no probe is attached. A belowMin (2) response indicates that the probe is present and its measured tem… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.10.2.2.1.9 |
||||||||||||
|
Sensor humidity reading in percent relative humidity
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.10.2.2.1.10 |
||||||||||||
|
This OID reports the current state of the humidity probe.
A notPresent (1) response indicates that no probe is attached. A belowMin (2) response indicates that the probe is present and its measured humidi… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.10.2.2.1.11 |
||||||||||||
|
Sensor peak temperature in tenths of degrees Fahrenheit
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.10.2.2.1.12 |
||||||||||||
|
Sensor peak temperature in tenths of degrees Celsius
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.10.2.2.1.13 |
||||||||||||
|
Indicates the date and time that the peak temperature occurred
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.10.2.2.1.14 |
||||||||||||
|
Indicates the date and time of the last temperature peak reset
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.10.2.2.1.15 |
.1.3.6.1.4.1.318.1.1.26.10.4.1
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDU2SensorDiscreteConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDU2SensorDiscreteConfigTable'
A table of discrete sensor configuration data
Configuration data from discreste sensor
being queried
being queried
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
rPDU2SensorDiscreteConfigIndexmandatory
The index to the discrete sensor configuration
data table entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.10.4.1.1.1 |
||||||
|
rPDU2SensorDiscreteConfigModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.10.4.1.1.2 |
||||||
|
rPDU2SensorDiscreteConfigNamemandatory
The user-defined discrete sensor ID string
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.26.10.4.1.1.3 |
||||||
|
rPDU2SensorDiscreteConfigNumbermandatory
The discrete sensor numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.10.4.1.1.4 |
||||||
|
rPDU2SensorDiscreteConfigNormalStatemandatory
Indicates the normal state of the discrete input
contact |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.10.4.1.1.5 |
||||||
|
Indicates the severity of alarm triggered by
abnormal discrete input contact state |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.10.4.1.1.6 |
.1.3.6.1.4.1.318.1.1.26.10.4.2
·
1 row entry
·
8 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDU2SensorDiscreteStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDU2SensorDiscreteStatusTable'
A table of discrete sensor status data
Status information from discrete sensor
being queried
being queried
Indexes
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
rPDU2SensorDiscreteStatusIndexmandatory
The index to the discrete sensor status data
table entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.10.4.2.1.1 |
||||||||||||||
|
rPDU2SensorDiscreteStatusModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.10.4.2.1.2 |
||||||||||||||
|
rPDU2SensorDiscreteStatusNamemandatory
The user-defined discrete sensor ID string
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.10.4.2.1.3 |
||||||||||||||
|
rPDU2SensorDiscreteStatusNumbermandatory
The discrete sensor numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.10.4.2.1.4 |
||||||||||||||
|
rPDU2SensorDiscreteStatusTypemandatory
The type of discrete sensor currently being queried
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.10.4.2.1.5 |
||||||||||||||
|
rPDU2SensorDiscreteStatusCommStatusmandatory
The communications status of the sensor
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.10.4.2.1.6 |
||||||||||||||
|
The current open/close state of the discrete
sensor |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.10.4.2.1.7 |
||||||||||||||
|
rPDU2SensorDiscreteStatusAlarmStatemandatory
Indicates alarm status of discrete sensor input
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.10.4.2.1.8 |
.1.3.6.1.4.1.318.1.1.26.10.6.1
·
1 row entry
·
7 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDU2SensorAnalogVoltageStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDU2SensorAnalogVoltageStatusTable'
A table of voltage sensor status data. Not supported by rPDU series 9000 or older.
Status information from voltage sensor
being queried
being queried
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
rPDU2SensorAnalogVoltageStatusIndexmandatory
The index to the voltage sensor status data
table entry |
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.318.1.1.26.10.6.1.1.1 |
||||||||||||
|
rPDU2SensorAnalogVoltageStatusModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.10.6.1.1.2 |
||||||||||||
|
rPDU2SensorAnalogVoltageStatusNumbermandatory
The voltage sensor numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.10.6.1.1.3 |
||||||||||||
|
rPDU2SensorAnalogVoltageStatusNamemandatory
The user-defined voltage sensor ID string
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.26.10.6.1.1.4 |
||||||||||||
|
The communications status of the sensor
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.10.6.1.1.5 |
||||||||||||
|
Sensor voltage reading in hundredths of volts.
Returns -1 for indices without voltage probes. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.10.6.1.1.6 |
||||||||||||
|
This OID reports the current state of the voltage probe:
A notPresent (1) response indicates that no probe is attached, or that the attached probe isn't a voltage probe. A belowMin (2) response indicates … |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.10.6.1.1.7 |
.1.3.6.1.4.1.318.1.1.26.10.6.2
·
1 row entry
·
8 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDU2SensorAnalogVoltageConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDU2SensorAnalogVoltageConfigTable'
A table of analog voltage sensor configuration data. Not supported by rPDU series 9000 or older.
Configuration data from analog voltage sensor
being queried
being queried
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
rPDU2SensorAnalogVoltageConfigIndexmandatory
The index to the voltage sensor configuration
data table entry |
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.318.1.1.26.10.6.2.1.1 |
||||
|
rPDU2SensorAnalogVoltageConfigModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.10.6.2.1.2 |
||||
|
rPDU2SensorAnalogVoltageConfigNumbermandatory
The voltage sensor numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.10.6.2.1.3 |
||||
|
rPDU2SensorAnalogVoltageConfigNamemandatory
The user-defined voltage sensor ID string.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.26.10.6.2.1.4 |
||||
|
Sensor minimum voltage alarm threshold in hundredths of volts.
This value may be as low as zero and must be less than rPDU2SensorAnalogVoltageConfigThreshMax. Returns -1 for indices without voltage probes. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.10.6.2.1.5 |
||||
|
Sensor minimum voltage alarm threshold in hundredths of volts.
This value must be greater than rPDU2SensorAnalogVoltageConfigThreshMin and may be as high as 50. Returns -1 for indices without voltage probes. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.10.6.2.1.6 |
||||
|
Sensor voltage hysteresis in hundredths of volts. This value may be
0 to 20. If either of the alarm thresholds are crossed, the measured voltage must recover by this amount before the alarm will be cleared. Returns -1 f… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.10.6.2.1.7 |
||||
|
This OID may be used to enable or disable voltage alarm generation.
Disabling alarm generation while alarms are active clears the active alarms. Returns -1 for indices without voltage probes. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.10.6.2.1.8 |
.1.3.6.1.4.1.318.1.1.26.13.1
·
1 row entry
·
5 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDU2PhaseToPhaseStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDU2PhaseToPhaseStatusTable'
A table of Rack PDU phase to phase status data. This table is only applicable to SKUs that have phase to phase outputs.
Status data from currently queried Rack PDU
phase to phase outputs
phase to phase outputs
Indexes
| Column | Syntax | OID |
|---|---|---|
|
rPDU2PhaseToPhaseStatusIndexmandatory
The index to the Rack PDU phase to phase status table
entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.13.1.1.1 |
|
rPDU2PhaseToPhaseStatusModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.13.1.1.2 |
|
rPDU2PhaseToPhaseStatusVoltage1to2mandatory
Indicates the Voltage, in Volts, of the Rack
PDU phase 1 to phase 2 output being queried |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.13.1.1.3 |
|
rPDU2PhaseToPhaseStatusVoltage2to3mandatory
Indicates the Voltage, in Volts, of the Rack
PDU phase 2 to phase 3 output being queried |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.13.1.1.4 |
|
rPDU2PhaseToPhaseStatusVoltage3to1mandatory
Indicates the Voltage, in Volts, of the Rack
PDU phase 3 to phase 2 output being queried |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.13.1.1.5 |
.1.3.6.1.4.1.318.1.1.26.14.1
·
1 row entry
·
8 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDU2AdvBankConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDU2AdvBankConfigTable'
A table of Rack PDU bank configuration data
Configuration data from currently queried
Rack PDU bank
Rack PDU bank
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
rPDU2AdvBankConfigIndexmandatory
The index to the Rack PDU bank configuration
table entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.14.1.1.1 |
||||||||
|
rPDU2AdvBankConfigModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.14.1.1.2 |
||||||||
|
rPDU2AdvBankConfigNumbermandatory
The numeric bank ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.14.1.1.3 |
||||||||
|
This OID controls the behavior of a Switched Rack PDU
bank when an overload condition is possible and additional outlets are requested to be turned on. Setting this OID to alwaysAllowTurnON (1) will alway… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.14.1.1.4 |
||||||||
|
User-defined low load bank current
threshold in tenths of Amps |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.14.1.1.5 |
||||||||
|
User-defined near bank overload current warning
threshold in tenths of Amps |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.14.1.1.6 |
||||||||
|
User-defined bank overload current threshold
in tenths of Amps |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.14.1.1.7 |
||||||||
|
Setting this OID to reset (2) will cause the existing peak current value
to be replaced by the present load current value. Getting this OID will do nothing and return the noOperation(1) value. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.14.1.1.8 |
.1.3.6.1.4.1.318.1.1.26.15.1
·
1 row entry
·
8 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk rPDU2AdvPhaseConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::rPDU2AdvPhaseConfigTable'
A table of Rack PDU phase configuration data
Configuration data from currently queried Rack
PDU phase
PDU phase
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
rPDU2AdvPhaseConfigIndexmandatory
The index to the Rack PDU phase configuration
table entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.15.1.1.1 |
||||||||
|
rPDU2AdvPhaseConfigModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.15.1.1.2 |
||||||||
|
rPDU2AdvPhaseConfigNumbermandatory
The numeric phase ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.15.1.1.3 |
||||||||
|
This OID controls the behavior of a Switched Rack PDU
phase when an overload condition is possible and additional outlets are requested to be turned on. Setting this OID to alwaysAllowTurnON (1) will alwa… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.15.1.1.4 |
||||||||
|
User-defined low load phase current
threshold measured in tenths of Amps |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.15.1.1.5 |
||||||||
|
User-defined near phase overload warning
threshold measured in tenths of Amps |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.15.1.1.6 |
||||||||
|
User-defined phase overload current
threshold measured in tenths of Amps |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.26.15.1.1.7 |
||||||||
|
Setting this OID to reset (2) will cause the existing peak current value
to be replaced by the present load current value. Getting this OID will do nothing and return the noOperation(1) value. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.26.15.1.1.8 |
.1.3.6.1.4.1.318.1.1.27.1.2
·
1 row entry
·
1 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk coolingUnitTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::coolingUnitTable'
A table of cooling unit level data.
An element of coolingUnitTable.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
coolingUnitTableIndexmandatory
The unit reference identifier for this table and all other table entries subordinate to coolingUnits.
|
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.318.1.1.27.1.2.1.1 |
.1.3.6.1.4.1.318.1.1.27.1.3.2
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk coolingUnitAboutTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::coolingUnitAboutTable'
A table of unit reference information.
An element of coolingUnitAboutTable.
| Column | Syntax | OID |
|---|---|---|
|
coolingUnitAboutTableIndexmandatory
The static reference identifier for each table entry.
|
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.318.1.1.27.1.3.2.1.1 |
|
coolingUnitAboutDescriptionmandatory
A text description of the information presented in coolingUnitAboutValue.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.27.1.3.2.1.2 |
|
coolingUnitAboutValuemandatory
The actual value of the current table entry.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.27.1.3.2.1.3 |
.1.3.6.1.4.1.318.1.1.27.1.4.1.2
·
1 row entry
·
5 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk coolingUnitStatusAnalogTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::coolingUnitStatusAnalogTable'
A table of analog unit status data.
An element of coolingUnitStatusAnalogTable.
| Column | Syntax | OID |
|---|---|---|
|
coolingUnitStatusAnalogTableIndexmandatory
The static reference identifier for each table entry.
|
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.318.1.1.27.1.4.1.2.1.1 |
|
coolingUnitStatusAnalogDescriptionmandatory
A text description of the information presented in coolingUnitStatusAnalogValue.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.27.1.4.1.2.1.2 |
|
coolingUnitStatusAnalogValuemandatory
The scaled value of the current table entry (multiplied by coolingUnitStatusAnalogScale for integer presentation).
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.27.1.4.1.2.1.3 |
|
coolingUnitStatusAnalogUnitsmandatory
The unit of measure by which coolingUnitStatusAnalogValue is expressed.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.27.1.4.1.2.1.4 |
|
coolingUnitStatusAnalogScalemandatory
The factor by which coolingUnitStatusAnalogValue is expressed.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.27.1.4.1.2.1.5 |
.1.3.6.1.4.1.318.1.1.27.1.4.2.2
·
1 row entry
·
5 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk coolingUnitStatusDiscreteTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::coolingUnitStatusDiscreteTable'
A table of discrete unit status data.
An element of coolingUnitStatusDiscreteTable.
| Column | Syntax | OID |
|---|---|---|
|
coolingUnitStatusDiscreteTableIndexmandatory
The static reference identifier for each table entry.
|
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.318.1.1.27.1.4.2.2.1.1 |
|
coolingUnitStatusDiscreteDescriptionmandatory
A text description of the information presented in this table's 'value' OIDs.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.27.1.4.2.2.1.2 |
|
The actual value of the current table entry expressed as a string.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.27.1.4.2.2.1.3 |
|
The actual value of the current table entry expressed as an integer value.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.27.1.4.2.2.1.4 |
|
A complete listing of all possible coolingUnitStatusDiscreteValueAsInteger values paired with their identifying strings.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.27.1.4.2.2.1.5 |
.1.3.6.1.4.1.318.1.1.27.1.5.1.2
·
1 row entry
·
8 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk coolingUnitConfigurationAnalogTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::coolingUnitConfigurationAnalogTable'
A table of analog unit configuration data.
An element of coolingUnitConfigurationAnalogTable.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
The static reference identifier for each table entry.
|
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.318.1.1.27.1.5.1.2.1.1 |
||||
|
A text description of the information presented in coolingUnitConfigurationAnalogValue.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.27.1.5.1.2.1.2 |
||||
|
coolingUnitConfigurationAnalogValuemandatory
The scaled value of the current table entry (multiplied by coolingUnitConfigurationAnalogScale for integer presentation).
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.27.1.5.1.2.1.3 |
||||
|
coolingUnitConfigurationAnalogUnitsmandatory
The unit of measure by which coolingUnitConfigurationAnalogValue is expressed.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.27.1.5.1.2.1.4 |
||||
|
coolingUnitConfigurationAnalogScalemandatory
The factor by which coolingUnitConfigurationAnalogValue is expressed.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.27.1.5.1.2.1.5 |
||||
|
coolingUnitConfigurationAnalogAccessmandatory
A description of available access to coolingUnitConfigurationAnalogValue via SNMP client.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.27.1.5.1.2.1.6 |
||||
|
The minimum possible value of coolingUnitConfigurationAnalogValue.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.27.1.5.1.2.1.7 |
||||
|
The maximum possible value of coolingUnitConfigurationAnalogValue.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.27.1.5.1.2.1.8 |
.1.3.6.1.4.1.318.1.1.27.1.5.2.2
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk coolingUnitConfigurationDiscreteTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::coolingUnitConfigurationDiscreteTable'
A table of discrete unit configuration data.
An element of coolingUnitConfigurationDiscreteTable.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
The static reference identifier for each table entry.
|
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.318.1.1.27.1.5.2.2.1.1 |
||||
|
A text description of the information presented in this table's 'value' OIDs.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.27.1.5.2.2.1.2 |
||||
|
The actual value of the current table entry expressed as a string.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.27.1.5.2.2.1.3 |
||||
|
The actual value of the current table entry expressed as an integer value.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.27.1.5.2.2.1.4 |
||||
|
A complete listing of all possible coolingUnitConfigurationDiscreteValueAsInteger values paired with their identifying strings.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.27.1.5.2.2.1.5 |
||||
|
A description of available access to coolingUnitConfigurationDiscreteValueAsInteger via SNMP client.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.27.1.5.2.2.1.6 |
.1.3.6.1.4.1.318.1.1.27.1.5.3.2
·
1 row entry
·
5 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk coolingUnitConfigurationStringTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::coolingUnitConfigurationStringTable'
A table of unit configuration strings.
An element of coolingUnitConfigurationStringTable.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
The static reference identifier for each table entry.
|
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.318.1.1.27.1.5.3.2.1.1 |
||||
|
A text description of the information presented in coolingUnitConfigurationStringValue.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.27.1.5.3.2.1.2 |
||||
|
coolingUnitConfigurationStringValuemandatory
The actual value of the current table entry.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.27.1.5.3.2.1.3 |
||||
|
The maximum string length supported by coolingUnitConfigurationStringValue.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.27.1.5.3.2.1.4 |
||||
|
coolingUnitConfigurationStringAccessmandatory
A description of available access to coolingUnitConfigurationStringValue via SNMP client.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.27.1.5.3.2.1.5 |
.1.3.6.1.4.1.318.1.1.27.1.6.1.2
·
1 row entry
·
5 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk coolingUnitExtendedAnalogTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::coolingUnitExtendedAnalogTable'
A table of secondary analog data for the cooling unit or one of its components.
An element of coolingUnitExtendedAnalogTable.
| Column | Syntax | OID |
|---|---|---|
|
coolingUnitExtendedAnalogTableIndexmandatory
The static reference identifier for each table entry. This identifier may reference different table entries in different unit models.
|
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.318.1.1.27.1.6.1.2.1.1 |
|
coolingUnitExtendedAnalogDescriptionmandatory
A text description of the information presented in coolingUnitExtendedAnalogValue.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.27.1.6.1.2.1.2 |
|
coolingUnitExtendedAnalogValuemandatory
The scaled value of the current table entry (multiplied by coolingUnitExtendedAnalogScale for integer presentation).
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.27.1.6.1.2.1.3 |
|
coolingUnitExtendedAnalogUnitsmandatory
The unit of measure by which coolingUnitExtendedAnalogValue is expressed.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.27.1.6.1.2.1.4 |
|
coolingUnitExtendedAnalogScalemandatory
The factor by which coolingUnitExtendedAnalogValue is expressed.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.27.1.6.1.2.1.5 |
.1.3.6.1.4.1.318.1.1.27.1.6.2.2
·
1 row entry
·
5 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk coolingUnitExtendedDiscreteTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::coolingUnitExtendedDiscreteTable'
A table of secondary discrete cooling unit data.
An element of coolingUnitExtendedDiscreteTable.
| Column | Syntax | OID |
|---|---|---|
|
The static reference identifier for each table entry. This identifier may reference different table entries in different unit models.
|
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.318.1.1.27.1.6.2.2.1.1 |
|
A text description of the information presented in this table's 'value' OIDs.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.27.1.6.2.2.1.2 |
|
The actual value of the current table entry expressed as a string.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.27.1.6.2.2.1.3 |
|
The actual value of the current table entry expressed as an integer value.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.27.1.6.2.2.1.4 |
|
A complete listing of all possible coolingUnitExtendedDiscreteValueAsInteger values paired with their identifying strings.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.27.1.6.2.2.1.5 |
.1.3.6.1.4.1.318.1.1.27.1.6.3.2
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk coolingUnitExtendedStringTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::coolingUnitExtendedStringTable'
A table of secondary unit reference data.
An element of coolingUnitExtendedStringTable.
| Column | Syntax | OID |
|---|---|---|
|
coolingUnitExtendedStringTableIndexmandatory
The static reference identifier for each table entry. This identifier may reference different table entries in different unit models.
|
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.318.1.1.27.1.6.3.2.1.1 |
|
coolingUnitExtendedStringDescriptionmandatory
A text description of the information presented in coolingUnitExtendedStringValue.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.27.1.6.3.2.1.2 |
|
coolingUnitExtendedStringValuemandatory
The actual value of the current table entry.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.27.1.6.3.2.1.3 |
.1.3.6.1.4.1.318.1.1.28.3.1.2
·
1 row entry
·
56 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk pmmInputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::pmmInputTable'
A list of input meter entries.
An entry containing information applicable to a
particular input meter.
particular input meter.
Indexes
| Column | Syntax | OID | ||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
pmmInputMeterIndexmandatory
The input meter identifier.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.1 |
||||||||||||||||||||
|
pmmInputFrequencymandatory
The input frequency in tenths of Hertz.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.2 |
||||||||||||||||||||
|
pmmInputTotalActivePowermandatory
Shows the total input active power in tenths of kW.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.3 |
||||||||||||||||||||
|
pmmInputTotalApparentPowermandatory
Shows the total input apparent power in tenths of kVA.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.4 |
||||||||||||||||||||
|
pmmInputTotalPowerFactormandatory
Indicates the total power factor. A value of 100 representing
a unity power factor (1.00). Specified in hundredths. Returns -255 if unsupported |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.5 |
||||||||||||||||||||
|
pmmInputActiveEnergyDeliveredmandatory
Shows the input active energy delivered in tenths of kWh.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.6 |
||||||||||||||||||||
|
pmmInputActiveEnergyReceivedmandatory
Shows the input active energy received in tenths of kWh.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.7 |
||||||||||||||||||||
|
pmmInputApparentEnergyDeliveredmandatory
Shows the input apparent energy delivered in tenths of kVAh.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.8 |
||||||||||||||||||||
|
pmmInputApparentEnergyReceivedmandatory
Shows the input apparent energy received in tenths of kVAh.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.9 |
||||||||||||||||||||
|
pmmInputFrequencyDeviationmandatory
Displays the input frequency deviation in Hertz.
Threshold write returns as unsuccessful if one of the breaker threshold groups does not meet conditions. In this case, read the thresholds to know which threshold group… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.10 |
||||||||||||||||||||
|
pmmInputPowerFactorDeviationmandatory
Displays the input power factor deviation. Specified in tenths.
A value of zero indicates that the threshold is disabled. Returns -1 if unsupported. Threshold write returns as unsuccessful if one of the breaker threshol… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.11 |
||||||||||||||||||||
|
pmmInputMinVoltThresholdmandatory
Threshold below which an input minimum voltage condition
will be generated. Specified as percent deviation from nominal voltage represented in the OID pmmDeviceNominalInputVoltage. A value of zero indicates that the thr… |
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.12 |
||||||||||||||||||||
|
pmmInputLowVoltThresholdmandatory
Threshold below which an input low voltage condition
will be generated. Specified as percent deviation from nominal voltage represented in the OID pmmDeviceNominalInputVoltage. A value of zero indicates that the thresho… |
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.13 |
||||||||||||||||||||
|
pmmInputHighVoltThresholdmandatory
Threshold above which an input high voltage condition
will be generated. Specified as percent deviation from nominal voltage represented in the OID pmmDeviceNominalInputVoltage. A value of zero indicates that the thresh… |
Integer32r/w Constraints: range: 0-120 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.14 |
||||||||||||||||||||
|
pmmInputMaxVoltThresholdmandatory
Threshold above which an input maximum voltage condition
will be generated. Specified as percent deviation from nominal voltage represented in the OID pmmDeviceNominalInputVoltage. A value of zero indicates that the thr… |
Integer32r/w Constraints: range: 0-120 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.15 |
||||||||||||||||||||
|
pmmInputMinCurrentThresholdmandatory
Threshold below which an input minimum current condition will be generated.
Specified as a percent of the panel breaker rating. A value of zero indicates that the threshold is disabled. Threshold write returns as unsucc… |
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.16 |
||||||||||||||||||||
|
pmmInputLowCurrentThresholdmandatory
Threshold below which an input low current condition will be generated.
Specified as a percent of the panel breaker rating. A value of zero indicates that the threshold is disabled. Threshold write returns as unsuccessf… |
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.17 |
||||||||||||||||||||
|
pmmInputHighCurrentThresholdmandatory
Threshold above which an input high current condition will be generated.
Specified as a percent of the panel breaker rating. A value of zero indicates that the threshold is disabled. Threshold write returns as unsuccess… |
Integer32r/w Constraints: range: 0-110 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.18 |
||||||||||||||||||||
|
pmmInputMaxCurrentThresholdmandatory
Threshold above which an input maximum current condition will be generated.
Specified as a percent of the panel breaker rating. A value of zero indicates that the threshold is disabled. Threshold write returns as unsucc… |
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.19 |
||||||||||||||||||||
|
pmmInputMinApparentPowerThresholdmandatory
Threshold below which an input minimum apparent power condition will be generated.
Specified as a percent deviation from nominal power rating. A value of zero indicates that the threshold is disabled. Threshold write re… |
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.20 |
||||||||||||||||||||
|
pmmInputMaxApparentPowerThresholdmandatory
Threshold above which an input maximum apparent power condition will be generated.
Specified as a percent deviation from nominal power rating. A value of zero indicates that the threshold is disabled. Threshold write re… |
Integer32r/w Constraints: range: 0-110 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.21 |
||||||||||||||||||||
|
pmmInputOverActivePowerThresholdmandatory
Threshold above which an input over active power condition will be generated.
Specified as a percent deviation from nominal power rating. A value of zero indicates that the threshold is disabled. Threshold write returns… |
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.22 |
||||||||||||||||||||
|
pmmInputBreakerStatemandatory
This value indicates the current state of input breaker.
1 will indicate open, 2 will indicate closed, 3 will indicate unknown. Returns -1 if unsupported or failed. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.23 |
||||||||||||||||||||
|
pmmInputBreakerOpenAlarmmandatory
Breaker open alarm status.
1 will indicate enabled, 2 will indicate disabled, 3 will indicate unknown. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.24 |
||||||||||||||||||||
|
pmmInputAverageCurrentmandatory
Input Average current. Measured in tenths of Amps.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.25 |
||||||||||||||||||||
|
pmmInputNeturalCurrentmandatory
Input Neutral current. Measured in tenths of Amps.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.26 |
||||||||||||||||||||
|
Input maximum instantaneous neutral current. Measured in tenths of Amps.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.27 |
||||||||||||||||||||
|
pmmInputAverageCurrentTHDmandatory
Input average harmonic distortions.
Returns -1 if unsupported or failed. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.28 |
||||||||||||||||||||
|
pmmInputAverageVoltageLtoLmandatory
Input Average Line to Line voltage. Measured in tenths of Volts.
Returns -1 if unsupported or failed. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.29 |
||||||||||||||||||||
|
pmmInputAverageVoltageLtoNmandatory
Input Average Line to Neutral voltage. Measured in tenths of Volts.
Returns -1 if unsupported or failed. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.30 |
||||||||||||||||||||
|
pmmInputLoadmandatory
Total load of input breaker in percentage. Measured in tenths of percent.
Returns -1 if unsupported or failed. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.31 |
||||||||||||||||||||
|
pmmInputMeterFirmwareVersionmandatory
Shows the input meter firmware version.
Returns -1 if unsupported or failed. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.32 |
||||||||||||||||||||
|
pmmInputMeterSerialNumbermandatory
Shows the input meter serial number.
Returns -1 if unsupported or failed. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.28.3.1.2.1.33 |
||||||||||||||||||||
|
pmmInputEnergyUsageAccumulatedTotalmandatory
Shows the total accumulated input energy usage in kWh.
Measured in tenths of kWh. Returns -1 if unsupported or failed. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.34 |
||||||||||||||||||||
|
pmmInputPhaseLossmandatory
Threshold below which an input phase loss condition will be generated.
Specified as a percent deviation from phase to neutral nominal voltage. A value of zero indicates that the threshold is disabled. Returns -1 if unsu… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.35 |
||||||||||||||||||||
|
pmmInputBreakerCTSizemandatory
Shows the input breaker CT size.
Returns -1 if unsupported or failed. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.36 |
||||||||||||||||||||
|
pmmInputBreakerRatingmandatory
Shows the input breaker rating in Amps(A).
Returns -1 if unsupported or failed. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.37 |
||||||||||||||||||||
|
pmmInputKWHResetDatemandatory
The date that the kWh usage was reset, in the format mm/dd/yyyy.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.28.3.1.2.1.38 |
||||||||||||||||||||
|
pmmInputAlarmGenerationmandatory
Alarm generation status.
1 - enabled 2 - disabled 3 - unknown |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.39 |
||||||||||||||||||||
|
pmmInputVoltageMaximumAlarmmandatory
Voltage maximum alarm generation status.
1 - enabled 2 - disabled 3 - unknown |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.40 |
||||||||||||||||||||
|
pmmInputVoltageHighAlarmmandatory
Voltage high alarm generation status.
1 - enabled 2 - disabled 3 - unknown |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.41 |
||||||||||||||||||||
|
pmmInputVoltageLowAlarmmandatory
Voltage low alarm generation status.
1 - enabled 2 - disabled 3 - unknown |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.42 |
||||||||||||||||||||
|
pmmInputVoltageMinimumAlarmmandatory
Voltage minimum alarm generation status.
1 - enabled 2 - disabled 3 - unknown |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.43 |
||||||||||||||||||||
|
pmmInputCurrentMaximumAlarmmandatory
Current maximum alarm generation status.
1 - enabled 2 - disabled 3 - unknown |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.44 |
||||||||||||||||||||
|
pmmInputCurrentHighAlarmmandatory
Current high alarm generation status.
1 - enabled 2 - disabled 3 - unknown |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.45 |
||||||||||||||||||||
|
pmmInputCurrentLowAlarmmandatory
Current low alarm generation status.
1 - enabled 2 - disabled 3 - unknown |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.46 |
||||||||||||||||||||
|
pmmInputCurrentMinimumAlarmmandatory
Current minimum alarm generation status.
1 - enabled 2 - disabled 3 - unknown |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.47 |
||||||||||||||||||||
|
pmmInputApparentPowerMaximumAlarmmandatory
Apparent Power maximum alarm generation status.
1 - enabled 2 - disabled 3 - unknown |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.48 |
||||||||||||||||||||
|
pmmInputApparentPowerMinimumAlarmmandatory
Apparent Power minimum alarm generation status.
1 - enabled 2 - disabled 3 - unknown |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.49 |
||||||||||||||||||||
|
pmmInputKWOverAlarmmandatory
Over active power alarm generation status.
1 - enabled 2 - disabled 3 - unknown |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.50 |
||||||||||||||||||||
|
pmmInputPhaseLossAlarmmandatory
Phase loss alarm generation status.
1 - enabled 2 - disabled 3 - unknown |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.51 |
||||||||||||||||||||
|
pmmInputPowerFactorTotalAlarmmandatory
Total power factor alarm generation status.
1 - enabled 2 - disabled 3 - unknown |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.52 |
||||||||||||||||||||
|
pmmInputFrequencyDeviationAlarmmandatory
Frequency deviation alarm generation status.
1 - enabled 2 - disabled 3 - unknown |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.53 |
||||||||||||||||||||
|
pmmInputNeutralOverCurrentAlarmmandatory
Neutral Overcurrent alarm generation status.
1 - enabled 2 - disabled 3 - unknown |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.54 |
||||||||||||||||||||
|
pmmInputNeutralOverCurrentThresholdmandatory
Threshold above which an input neutral overcurrent condition will be generated.
Specified as a percent deviation from nominal current. A value of zero indicates that the threshold is disabled. Returns -1 if unsupported … |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.55 |
||||||||||||||||||||
|
pmmInputAveragePowerFactormandatory
Indicates the average power factor. A value of 100 representing
a unity power factor (1.00). Specified in hundredths. Returns -255 if unsupported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.2.1.56 |
.1.3.6.1.4.1.318.1.1.28.3.1.3
·
1 row entry
·
13 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk pmmInputPhaseTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::pmmInputPhaseTable'
A list of input table entries. The number of entries is given by the value of pmmInputMeterTableSize OID.
An entry containing information applicable to a
particular input phase.
particular input phase.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
pmmInputMeterNummandatory
The input meter identifier.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.3.1.1 |
|
pmmInputPhasemandatory
Input phase index.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.3.1.2 |
|
pmmInputVoltageLtoLmandatory
Line-to-line input voltage available.
Measured in tenths of Volts. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.3.1.3 |
|
pmmInputVoltageLtoNmandatory
Line-to-neutral input voltage available.
Measured in tenths of Volts. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.3.1.4 |
|
pmmInputPhaseCurrentmandatory
Input current per phase. Measured in tenths of Amps.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.3.1.5 |
|
pmmInputActivePowermandatory
Input active power per phase. Measured in tenths of kW.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.3.1.6 |
|
pmmInputApparentPowermandatory
Input apparent power per phase. Measured in tenths of kVA.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.3.1.7 |
|
pmmInputPowerFactormandatory
Indicates the power factor of the input per phase.
A value of 100 representing a unity power factor (1.00). Specified in hundredths. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.3.1.8 |
|
pmmInputMaxInstantaneousCurrentmandatory
Input maximum phase instantaneous current. Measured in tenths of Amps.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.3.1.9 |
|
pmmInputPhaseAnglemandatory
Current phase Angle. Measured in tenths of decimal
Returns -255 if unsupported |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.3.1.10 |
|
pmmInputTHDLtoLmandatory
Input harmonic distortions line to line for the present input voltage.
Measured in tenths. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.3.1.11 |
|
pmmInputTHDLtoNmandatory
Input harmonic distortions line to neutral for the present input voltage.
Measured in tenths. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.3.1.12 |
|
pmmInputCurrentTHDmandatory
Input harmonic distortions for each phase, for the present input current.
Returns -1 if unsupported or failed. Specified in tenths. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.1.3.1.13 |
.1.3.6.1.4.1.318.1.1.28.3.2.2
·
1 row entry
·
25 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk pmmOutputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::pmmOutputTable'
A list of output meter entries.
An entry containing information applicable to a
particular output meter.
particular output meter.
Indexes
| Column | Syntax | OID | ||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
pmmOutputMeterIndexmandatory
The output meter identifier.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.2.2.1.1 |
||||||||||||||||||||
|
pmmOutputFrequencymandatory
The output frequency in tenths of Hertz.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.2.2.1.2 |
||||||||||||||||||||
|
pmmOutputTotalActivePowermandatory
Shows the total output active power in tenths of kW.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.2.2.1.3 |
||||||||||||||||||||
|
pmmOutputTotalApparentPowermandatory
Shows the total output apparent power in tenths of kVA.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.2.2.1.4 |
||||||||||||||||||||
|
pmmOutputTotalPowerFactormandatory
Indicates the total power factor. A value of 100 representing
a unity power factor (1.00). Specified in hundredths. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.2.2.1.5 |
||||||||||||||||||||
|
pmmOutputActiveEnergyDeliveredmandatory
Shows the output active energy delivered in tenths of kWh.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.2.2.1.6 |
||||||||||||||||||||
|
pmmOutputActiveEnergyReceivedmandatory
Shows the output active energy received in tenths of kWh.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.2.2.1.7 |
||||||||||||||||||||
|
pmmOutputApparentEnergyDeliveredmandatory
Shows the output apparent energy delivered in tenths of kVAh.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.2.2.1.8 |
||||||||||||||||||||
|
pmmOutputApparentEnergyReceivedmandatory
Shows the output apparent energy received in tenths of kVAh.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.2.2.1.9 |
||||||||||||||||||||
|
pmmOutputFrequencyDeviationmandatory
Shows the output frequency deviation in Hertz.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.28.3.2.2.1.10 |
||||||||||||||||||||
|
pmmOutputPowerFactorDeviationmandatory
Shows the output power factor deviation. Specified in tenths.
A value of zero indicates that the threshold is disabled. |
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.318.1.1.28.3.2.2.1.11 |
||||||||||||||||||||
|
pmmOutputMinVoltThresholdmandatory
Threshold below which an output minimum voltage condition
will be generated. Specified as percent deviation from nominal voltage represented in the OID pmmDeviceNominalOutputVoltage. A value of zero indicates that the t… |
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.318.1.1.28.3.2.2.1.12 |
||||||||||||||||||||
|
pmmOutputLowVoltThresholdmandatory
Threshold below which an output low voltage condition
will be generated. Specified as percent deviation from nominal voltage represented in the OID pmmDeviceNominalOutputVoltage. A value of zero indicates that the thres… |
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.318.1.1.28.3.2.2.1.13 |
||||||||||||||||||||
|
pmmOutputHighVoltThresholdmandatory
Threshold above which an output high voltage condition
will be generated. Specified as percent deviation from nominal voltage represented in the OID pmmDeviceNominalOutputVoltage. A value of zero indicates that the thre… |
Integer32r/w Constraints: range: 0-120 |
.1.3.6.1.4.1.318.1.1.28.3.2.2.1.14 |
||||||||||||||||||||
|
pmmOutputMaxVoltThresholdmandatory
Threshold above which an output maximum voltage condition
will be generated. Specified as percent deviation from nominal voltage represented in the OID pmmDeviceNominalOutputVoltage. A value of zero indicates that the t… |
Integer32r/w Constraints: range: 0-120 |
.1.3.6.1.4.1.318.1.1.28.3.2.2.1.15 |
||||||||||||||||||||
|
pmmOutputMinCurrentThresholdmandatory
Threshold below which an output minimum current condition will be generated.
Specified as a percent of the panel breaker rating. A value of zero indicates that the threshold is disabled. |
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.318.1.1.28.3.2.2.1.16 |
||||||||||||||||||||
|
pmmOutputLowCurrentThresholdmandatory
Threshold below which an output low current condition will be generated.
Specified as a percent of the panel breaker rating. A value of zero indicates that the threshold is disabled. |
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.318.1.1.28.3.2.2.1.17 |
||||||||||||||||||||
|
pmmOutputHighCurrentThresholdmandatory
Threshold above which an output high current condition will be generated.
Specified as a percent of the panel breaker rating. A value of zero indicates that the threshold is disabled. |
Integer32r/w Constraints: range: 0-110 |
.1.3.6.1.4.1.318.1.1.28.3.2.2.1.18 |
||||||||||||||||||||
|
pmmOutputMaxCurrentThresholdmandatory
Threshold above which an output maximum current condition will be generated.
Specified as a percent of the panel breaker rating. A value of zero indicates that the threshold is disabled. |
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.318.1.1.28.3.2.2.1.19 |
||||||||||||||||||||
|
pmmOutputMinApparentPowerThresholdmandatory
Threshold below which an output minimum apparent power condition will be generated.
Specified as a percent deviation from nominal power rating. A value of zero indicates that the threshold is disabled. |
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.318.1.1.28.3.2.2.1.20 |
||||||||||||||||||||
|
pmmOutputMaxApparentPowerThresholdmandatory
Threshold above which an output maximum apparent power condition will be generated.
Specified as a percent deviation from nominal power rating. A value of zero indicates that the threshold is disabled. |
Integer32r/w Constraints: range: 0-110 |
.1.3.6.1.4.1.318.1.1.28.3.2.2.1.21 |
||||||||||||||||||||
|
pmmOutputOverActivePowerThresholdmandatory
Threshold above which an output over active power condition will be generated.
Specified as a percent deviation from nominal power rating. A value of zero indicates that the threshold is disabled. |
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.318.1.1.28.3.2.2.1.22 |
||||||||||||||||||||
|
pmmOutputPhaseLossThresholdmandatory
Threshold below which an output phase loss condition will be generated.
Specified as a percent deviation from nominal voltage represented in the OID pmmDeviceNominalOutputVoltage. A value of zero indicates that the thre… |
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.318.1.1.28.3.2.2.1.23 |
||||||||||||||||||||
|
pmmOutputBreakerStatemandatory
This value indicates the current state of output breaker.
1 will indicate open, 2 will indicate closed, 3 will indicate unknown. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.28.3.2.2.1.24 |
||||||||||||||||||||
|
pmmOutputBreakerOpenAlarmmandatory
Breaker open alarm status.
1 will indicate enabled, 2 will indicate disabled, 3 will indicate unknown. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.28.3.2.2.1.25 |
.1.3.6.1.4.1.318.1.1.28.3.2.3
·
1 row entry
·
8 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk pmmOutputPhaseTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::pmmOutputPhaseTable'
A list of output table entries. The number of entries is given by the value of pmmOutputMeterTableSize OID.
An entry containing information applicable to a
particular output phase.
particular output phase.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
pmmOutputMeterNummandatory
The output meter identifier.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.2.3.1.1 |
|
pmmOutputPhasemandatory
Output phase index.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.2.3.1.2 |
|
pmmOutputVoltageLtoLmandatory
Line-to-line output voltage available.
Measured in tenths of Volts. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.2.3.1.3 |
|
pmmOutputVoltageLtoNmandatory
Line-to-neutral output voltage available.
Measured in tenths of Volts. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.2.3.1.4 |
|
pmmOutputPhaseCurrentmandatory
Load current per phase. Measured in tenths of Amps.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.2.3.1.5 |
|
pmmOutputActivePowermandatory
Output power per phase. Measured in tenths of kW.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.2.3.1.6 |
|
pmmOutputApparentPowermandatory
Output power per phase. Measured in tenths of kVA.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.2.3.1.7 |
|
pmmOutputPowerFactormandatory
Indicates the power factor of the output per phase.
A value of 100 representing a unity power factor (1.00). Specified in hundredths. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.2.3.1.8 |
.1.3.6.1.4.1.318.1.1.28.3.3.3
·
1 row entry
·
41 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk pmmBranchBreakerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::pmmBranchBreakerTable'
A list of branch breaker table entries. The number of entries is contained in the pmmBranchBreakerTableSize OID.
An entry containing information applicable to a
particular branch breaker (panel/circuit position).
particular branch breaker (panel/circuit position).
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
pmmBranchCircuitMeterIndexmandatory
Index of branch circuit meter in the table.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.3.3.1.1 |
||||||
|
pmmBranchCircuitIndexmandatory
The branch circuit index.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.3.3.1.2 |
||||||
|
pmmBranchCircuitNumberOfPolesmandatory
The number of poles.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.3.3.1.3 |
||||||
|
pmmBranchCircuitPhasemandatory
The phase associated with branch circuit.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.28.3.3.3.1.4 |
||||||
|
pmmBranchCircuitBreakerIdentifiermandatory
The branch circuit identifier.
Returns (-1) if not supported. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.28.3.3.3.1.5 |
||||||
|
pmmBranchCircuitLoadIdentifiermandatory
Identifies the name or location of the branch circuit load.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.28.3.3.3.1.6 |
||||||
|
pmmBranchCircuitCurrentmandatory
The branch circuit current Measured in tenths of Amps.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.3.3.1.7 |
||||||
|
pmmBranchCircuitBreakerRatingmandatory
The rating of the branch circuit breaker in Amps.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.3.3.1.8 |
||||||
|
pmmBranchCircuitTotalActivePowermandatory
Branch circuit total active power. Measured in tenths
of kW. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.3.3.1.9 |
||||||
|
pmmBranchCircuitTotalApparentPowermandatory
Branch circuit total apparent power. Measured in
tenths of kVA. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.3.3.1.10 |
||||||
|
pmmBranchCircuitEnergyUsagemandatory
Indicates the accumulated energy usage per phase in tenths of kWh.
Displayed as 0 when not available or no energy used. |
RFC1155-SMIGauge Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.318.1.1.28.3.3.3.1.11 |
||||||
|
pmmBranchCircuitEnergyUsageResetDatemandatory
The date that the kWh usage was reset, in the format mm/dd/yyyy.
The default energy usage reset date is Not Available. Displayed as NA when breaker is not installed or if not first pole of breaker. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.28.3.3.3.1.12 |
||||||
|
pmmBranchCircuitTotalPowerFactormandatory
Indicates the total power factor of the branch circuit.
A value of 100 representing a unity power factor (1.00) Specified in hundredths. Returns -1 if unsupported. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.3.3.1.13 |
||||||
|
pmmBranchCircuitBreakerStatemandatory
This value indicates the current state of branch
circuit breaker. 1 will indicate open, 2 will indicate closed, 3 will indicate unknown. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.28.3.3.3.1.14 |
||||||
|
pmmBranchCircuitMinCurrentThresholdmandatory
Threshold below which a branch circuit minimum current
condition will be generated. Specified as a percentage of the branch breaker rating represented in the OID pmmBranchCircuitBreakerRating A value of zero indicates t… |
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.318.1.1.28.3.3.3.1.15 |
||||||
|
pmmBranchCircuitLowCurrentThresholdmandatory
Threshold below which a branch circuit low current
condition will be generated. Specified as a percentage of the branch breaker rating represented in the OID pmmBranchCircuitBreakerRating A value of zero indicates that … |
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.318.1.1.28.3.3.3.1.16 |
||||||
|
pmmBranchCircuitHighCurrentThresholdmandatory
Threshold above which a branch circuit high current
condition will be generated. Specified as a percentage of the branch breaker rating represented in the OID pmmBranchCircuitBreakerRating A value of zero indicates that… |
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.318.1.1.28.3.3.3.1.17 |
||||||
|
pmmBranchCircuitMaxCurrentThresholdmandatory
Threshold above which a branch circuit maximum current
condition will be generated. Specified as a percentage of the branch breaker rating represented in the OID pmmBranchCircuitBreakerRating A value of zero indicates t… |
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.318.1.1.28.3.3.3.1.18 |
||||||
|
Threshold below which a branch circuit minimum apparent
power condition will be generated. Specified as a percent of the branch breaker apparent power rating. A value of zero indicates that the threshold is disabled. Th… |
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.318.1.1.28.3.3.3.1.19 |
||||||
|
Threshold above which a branch circuit maximum apparent
power condition will be generated. Specified as a percent of the branch breaker apparent power rating. A value of zero indicates that the threshold is disabled. Th… |
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.318.1.1.28.3.3.3.1.20 |
||||||
|
pmmBranchCircuitAlaramGenerationmandatory
Alarm generation status.
1 will indicate enabled, 2 will indicate disabled, 3 will indicate unknown. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.28.3.3.3.1.21 |
||||||
|
pmmBranchCircuitBreakerOpenAlarmmandatory
Breaker open alarm status.
1 will indicate enabled, 2 will indicate disabled, 3 will indicate unknown. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.28.3.3.3.1.22 |
||||||
|
Average branch breaker current. Measured in tenths of Amps.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.3.3.1.23 |
||||||
|
Branch circuit maximum instantaneous current. Measured in tenths of Amps.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.3.3.1.24 |
||||||
|
Average branch breaker maximum instantaneous current. Measured in tenths of Amps.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.3.3.1.25 |
||||||
|
pmmBranchCircuitAnglemandatory
Branch circuit phase angle. Measured in tenths of Decimal.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.3.3.1.26 |
||||||
|
pmmBranchCircuitActivePowermandatory
Branch circuit Active power. Measured in tenths of kW.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.3.3.1.27 |
||||||
|
pmmBranchCircuitApparentPowermandatory
Branch circuit apparent power. Measured in tenths of kVA.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.3.3.1.28 |
||||||
|
Indicates the circuit Breaker total accumulated energy usage in tenths of kWh.
Displayed as 0 when not available or no energy used. |
RFC1155-SMIGauge Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.318.1.1.28.3.3.3.1.29 |
||||||
|
pmmBranchCircuitPowerFactormandatory
Indicates the power factor of the branch circuit.
A value of 100 representing a unity power factor (1.00) Specified in hundredths. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.3.3.1.30 |
||||||
|
pmmBranchCircuitTHDmandatory
Branch circuit current harmonic distortion.
Specified in tenths of percent. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.3.3.1.31 |
||||||
|
pmmBranchCircuitBreakerTHDmandatory
Average branch breaker current harmonic distortion.
Specified in tenths of percent. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.3.3.1.32 |
||||||
|
pmmBranchCircuitBreakerLoadmandatory
Total load on the Breaker.
Measured in tenths of Amps. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.3.3.1.33 |
||||||
|
pmmBranchCircuitBranchNumbermandatory
The branch number.
Returns -1 if unsupported or failed. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.3.3.1.34 |
||||||
|
pmmBranchCircuitChannelCTSizemandatory
The branch CT Size.
Returns -1 if unsupported or failed. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.3.3.1.35 |
||||||
|
pmmBranchCircuitCurrentMaxAlarmmandatory
Current maximum alarm generation status.
1 - enabled 2 - disabled 3 - unknown |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.3.3.1.36 |
||||||
|
pmmBranchCircuitCurrentHighAlarmmandatory
Current high alarm generation status.
1 - enabled 2 - disabled 3 - unknown |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.3.3.1.37 |
||||||
|
pmmBranchCircuitCurrentLowAlarmmandatory
Current low alarm generation status.
1 - enabled 2 - disabled 3 - unknown |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.3.3.1.38 |
||||||
|
pmmBranchCircuitCurrentMinAlarmmandatory
Current minimum alarm generation status.
1 - enabled 2 - disabled 3 - unknown |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.3.3.1.39 |
||||||
|
Apparent power maximum alarm generation status.
1 - enabled 2 - disabled 3 - unknown |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.3.3.1.40 |
||||||
|
Apparent power minimum alarm generation status.
1 - enabled 2 - disabled 3 - unknown |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.3.3.1.41 |
.1.3.6.1.4.1.318.1.1.28.3.4.2
·
1 row entry
·
7 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk pmmSiteConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::pmmSiteConfigTable'
A list of PMM site configurable entries.
An entry containing information applicable to a
particular site configuration.
particular site configuration.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
pmmSiteConfigIndexmandatory
PMM site configuration identifier.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.4.2.1.1 |
||||
|
pmmSiteConfigNominalPtoPVoltagemandatory
The nominal input phase to phase voltage to the PMM. Measured in Volts,
line-to-line for a 3-wire (delta) service or line-to-neutral for a 4-wire (wye) service. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.4.2.1.2 |
||||
|
pmmSiteConfigNominalPtoNVoltagemandatory
The nominal input phase to neutral voltage to the PMM. Measured in Volts,
line-to-line for a 3-wire (delta) service or line-to-neutral for a 4-wire (wye) service. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.4.2.1.3 |
||||
|
pmmSiteConfigNominalCurrentmandatory
The nominal input current to the PMM. Measured in tenths of Amps.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.4.2.1.4 |
||||
|
pmmSiteConfigNominalFrequencymandatory
The nominal input frequency to the PMM. Measured in tenths of Hertz.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.4.2.1.5 |
||||
|
pmmSiteConfigNominalApparentPowermandatory
The nominal input apparent power to the PMM. Measured in tenths of kVA.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.28.3.4.2.1.6 |
||||
|
pmmSiteConfigServiceTypemandatory
The type of utility input to the PMM. Either 3 wires (delta), or 4 wires (wye).
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.28.3.4.2.1.7 |
.1.3.6.1.4.1.318.1.1.29.2.1
·
1 row entry
·
5 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk chargerInputPhaseTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::chargerInputPhaseTable'
A list of input table entries. The number of entries is given by the sum of the Charger input phases.
An entry containing information applicable to a
particular input phase.
particular input phase.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
chargerInputPhaseTableIndexmandatory
The input identifier.
If not supported, return 0. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.29.2.1.1.1 |
|
chargerInputPhaseVoltagemandatory
The input voltage in VAC, or -1 if it's unsupported
by this Charger. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.29.2.1.1.2 |
|
chargerInputPhaseMinVoltagemandatory
The lowest input voltage to the Charger during the previous minute of operation, or -1 if it's unsupported
by this Charger. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.29.2.1.1.3 |
|
chargerInputPhaseMaxVoltagemandatory
The highest input voltage to the Charger during the previous minute of operation, or -1 if it's unsupported
by this Charger. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.29.2.1.1.4 |
|
chargerInputPhaseCurrentmandatory
The input current in 0.1 amperes, or -1 if it's
unsupported by this Charger. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.29.2.1.1.5 |
.1.3.6.1.4.1.318.1.1.30.2.1
·
1 row entry
·
12 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk ePDUDeviceStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::ePDUDeviceStatusTable'
A table of Easy PDU status information
Status information from the Easy PDU being queried
Indexes
| Column | Syntax | OID |
|---|---|---|
|
ePDUDeviceStatusIndexmandatory
The index to the Easy PDU status table entry
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.2.1.1.1 |
|
ePDUDeviceStatusModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.2.1.1.2 |
|
ePDUDeviceStatusVersionmandatory
The Easy PDU firmware and hardware version
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.30.2.1.1.3 |
|
ePDUDeviceStatusModelNumbermandatory
The Easy PDU model number
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.30.2.1.1.4 |
|
ePDUDeviceStatusSerialNumbermandatory
The Easy PDU serial number
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.30.2.1.1.5 |
|
ePDUDeviceStatusNumPhasesmandatory
The number of phases present in the Easy PDU
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.2.1.1.6 |
|
ePDUDeviceStatusActivePowermandatory
Indicates the PDU Active Power. Units:1 Watt.
Models that do not support this feature, will respond to this OID with a value of notSupported (-1). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.2.1.1.7 |
|
ePDUDeviceStatusReactivePowermandatory
Indicates the PDU Reactive Power. Units:1 Var.
Models that do not support this feature, will respond to this OID with a value of notSupported (-1). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.2.1.1.8 |
|
ePDUDeviceStatusApparentPowermandatory
Indicates the PDU Apparent Power. Units:1 VA.
Models that do not support this feature, will respond to this OID with a value of notSupported (-1). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.2.1.1.9 |
|
ePDUDeviceStatusPowerFactormandatory
Indicates the PDU Power Factor. Units:0.1%.
Models that do not support this feature, will respond to this OID with a value of notSupported (-1). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.2.1.1.10 |
|
ePDUDeviceStatusEnergymandatory
Indicates the PDU Energy. Units:1 Wh.
Models that do not support this feature, will respond to this OID with a value of notSupported (-1). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.2.1.1.11 |
|
ePDUDeviceStatusFrequencymandatory
Indicates the PDU Frequency. Units:0.001 Hz.
Models that do not support this feature, will respond to this OID with a value of notSupported (-1). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.2.1.1.12 |
.1.3.6.1.4.1.318.1.1.30.2.2
·
1 row entry
·
5 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk ePDUDeviceControlTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::ePDUDeviceControlTable'
A table of Easy PDU control data
Control data from Easy PDU being queried
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
ePDUDeviceControlIndexmandatory
The index to the Easy PDU control table entry
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.2.2.1.1 |
||||
|
ePDUDeviceControlModulemandatory
The user-defined Easy PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.2.2.1.2 |
||||
|
ePDUDeviceControlRebootmandatory
Setting this OID to reboot (1) will cause the device reboot immediately.
Getting this OID in models that support this feature will do nothing and return the noOperation(0) value. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.30.2.2.1.3 |
||||
|
ePDUDeviceControlEnergyResetmandatory
Setting this OID to reset (1) will cause the device energy meter value
to be reset to zero. Getting this OID in models that support this feature will do nothing and return the noOperation(0) value. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.30.2.2.1.4 |
||||
|
ePDUDeviceControlBeepAlarmmandatory
User-defined Beep alarm, 1 for turn off Beep, 2 for turn on Beep.
Models that do not support this feature will respond to this OID with a value of -1. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.30.2.2.1.5 |
.1.3.6.1.4.1.318.1.1.30.4.1
·
1 row entry
·
7 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk ePDUPhaseConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::ePDUPhaseConfigTable'
A table of Easy PDU phase configuration data
Configuration data from currently queried Easy PDU phase
Indexes
| Column | Syntax | OID |
|---|---|---|
|
ePDUPhaseConfigIndexmandatory
The index to the Easy PDU phase configuration table entry
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.4.1.1.1 |
|
ePDUPhaseConfigModulemandatory
The user-defined Easy PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.4.1.1.2 |
|
ePDUPhaseConfigNumbermandatory
The numeric phase ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.4.1.1.3 |
|
ePDUPhaseConfigOverVoltageThresholdmandatory
User-defined Phase Over Voltage alarm threshold. Units:0.1 V.
Models that do not support this feature will respond to this OID with a value of -1. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.4.1.1.4 |
|
ePDUPhaseConfigLowVoltageThresholdmandatory
User-defined Phase Low Voltage alarm threshold. Units:0.1 V.
Models that do not support this feature will respond to this OID with a value of -1. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.4.1.1.5 |
|
ePDUPhaseConfigOverCurrentThresholdmandatory
User-defined Phase Over Current alarm threshold. Units:0.01 A.
Models that do not support this feature will respond to this OID with a value of -1. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.4.1.1.6 |
|
ePDUPhaseConfigLowCurrentThresholdmandatory
User-defined Phase Low Current alarm threshold. Units:0.01 A.
Models that do not support this feature will respond to this OID with a value of -1. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.4.1.1.7 |
.1.3.6.1.4.1.318.1.1.30.4.2
·
1 row entry
·
10 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk ePDUPhaseStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::ePDUPhaseStatusTable'
A table of Rack PDU phase status data
Status data from currently queried Easy PDU phase
Indexes
| Column | Syntax | OID |
|---|---|---|
|
ePDUPhaseStatusIndexmandatory
The index to the Easy PDU phase configuration table entry
|
Integer32 Constraints: range: 1-12 |
.1.3.6.1.4.1.318.1.1.30.4.2.1.1 |
|
ePDUPhaseStatusModulemandatory
The user-defined Easy PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.4.2.1.2 |
|
ePDUPhaseStatusNumbermandatory
The numeric phase ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.4.2.1.3 |
|
ePDUPhaseStatusVoltagemandatory
Indicates the Phase Voltage. Units:0.1 V
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.4.2.1.4 |
|
ePDUPhaseStatusCurrentmandatory
Indicates the Phase Current. Units:0.01 A
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.4.2.1.5 |
|
ePDUPhaseStatusActivePowermandatory
Indicates the Phase Active Power. Units:1 Watt
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.4.2.1.6 |
|
ePDUPhaseStatusReactivePowermandatory
Indicates the Phase Reactive Power. Units:1 Var.
Models that do not support this feature, will respond to this OID with a value of notSupported (-1). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.4.2.1.7 |
|
ePDUPhaseStatusApparentPowermandatory
Indicates the Phase Apparent Power. Units:1 VA.
Models that do not support this feature, will respond to this OID with a value of notSupported (-1). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.4.2.1.8 |
|
ePDUPhaseStatusPowerFactormandatory
Indicates the Phase Power Factor. Units:0.1%
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.4.2.1.9 |
|
ePDUPhaseStatusEnergymandatory
Indicates the Phase Energy. Units:1 Wh
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.4.2.1.10 |
.1.3.6.1.4.1.318.1.1.30.6.1
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk ePDUOutletStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::ePDUOutletStatusTable'
The number of switched outlets on connected Rack PDUs
Switched Outlet status from currently queried
Easy PDU switched outlet
Easy PDU switched outlet
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
ePDUOutletStatusIndexmandatory
The index to the Easy PDU switched outlet status information table entry.
Models that do not support this feature, will respond to this OID with a value of notSupported (-1). |
Integer32 Constraints: range: 1-128 |
.1.3.6.1.4.1.318.1.1.30.6.1.1.1 |
||||
|
ePDUOutletStatusModulemandatory
The user-defined Easy PDU numeric ID.
Models that do not support this feature, will respond to this OID with a value of notSupported (-1). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.6.1.1.2 |
||||
|
ePDUOutletStatusNumbermandatory
The numeric switched outlet ID.
Models that do not support this feature, will respond to this OID with a value of notSupported (-1). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.6.1.1.3 |
||||
|
ePDUOutletStatusStatemandatory
Indicates the present switch state of the Easy PDU switched outlet being queried.
Models that do not support this feature, will respond to this OID with a value of notSupported (-1). |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.30.6.1.1.4 |
.1.3.6.1.4.1.318.1.1.30.6.2
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk ePDUOutletControlTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::ePDUOutletControlTable'
A table of Easy PDU switched outlet control data
Control data for currently queried Easy PDU switched outlet
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
ePDUOutletControlIndexmandatory
The index to the Easy PDU switched outlet configuration table entry.
Models that do not support this feature, will respond to this OID with a value of notSupported (-1). |
Integer32 Constraints: range: 1-128 |
.1.3.6.1.4.1.318.1.1.30.6.2.1.1 |
||||||
|
ePDUOutletControlModulemandatory
The user-defined Easy PDU numeric ID.
Models that do not support this feature, will respond to this OID with a value of notSupported (-1). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.6.2.1.2 |
||||||
|
ePDUOutletControlNumbermandatory
The numeric switched outlet ID.
Models that do not support this feature, will respond to this OID with a value of notSupported (-1). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.6.2.1.3 |
||||||
|
ePDUOutletControlCommandmandatory
Getting this variable will return the outlet state. If
the outlet is on, the immediateOn (1) value will be returned. If the outlet is off, the immediateOff (2) value will be returned. If the state of the outlet cannot b… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.30.6.2.1.4 |
.1.3.6.1.4.1.318.1.1.30.8.1
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk ePDUSensorConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::ePDUSensorConfigTable'
A table of temperature-humidity sensor configuration data
Configuration data from temperature-humidity sensor being queried
Indexes
| Column | Syntax | OID |
|---|---|---|
|
ePDUSensorConfigIndexmandatory
The index to the temperature-humidity sensor configuration data table entry
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.8.1.1.1 |
|
ePDUSensorConfigModulemandatory
The user-defined Easy PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.8.1.1.2 |
|
ePDUSensorConfigTempMaxThresholdmandatory
User-defined Max Temperature alarm threshold. Units: 0.1 degrees Celsius.
Models that do not support this feature will respond to this OID with a value of -1. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.8.1.1.3 |
|
ePDUSensorConfigTempMinThresholdmandatory
User-defined Min Temperature alarm threshold. Units: 0.1 degrees Celsius.
Models that do not support this feature will respond to this OID with a value of -1. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.8.1.1.4 |
|
ePDUSensorConfigHumidityMaxThresholdmandatory
User-defined Max Humidity alarm threshold. Units: 0.1% relative humidity.
Models that do not support this feature will respond to this OID with a value of -1. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.8.1.1.5 |
|
ePDUSensorConfigHumidityMinThresholdmandatory
User-defined Min Humidity alarm threshold. Units: 0.1% relative humidity.
Models that do not support this feature will respond to this OID with a value of -1. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.8.1.1.6 |
.1.3.6.1.4.1.318.1.1.30.8.2
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk ePDUSensorStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::ePDUSensorStatusTable'
A table of temperature-humidity sensor status data
Status information from temperature-humidity sensor being queried
Indexes
| Column | Syntax | OID |
|---|---|---|
|
ePDUSensorStatusIndexmandatory
The index to the temperature-humidity status data table entry
|
Integer32 Constraints: range: 1-4 |
.1.3.6.1.4.1.318.1.1.30.8.2.1.1 |
|
ePDUSensorStatusModulemandatory
The user-defined Easy PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.8.2.1.2 |
|
ePDUSensorStatusTemperaturemandatory
Sensor temperature reading in tenths of degrees Celsius.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.8.2.1.3 |
|
ePDUSensorStatusHumiditymandatory
Sensor humidity reading in 0.1 percent relative humidity.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.30.8.2.1.4 |
.1.3.6.1.4.1.318.1.1.31.2.2.1
·
1 row entry
·
2 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk mdcUpsInputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::mdcUpsInputTable'
A list of UPS input table entries. The number of entries is given by the value of mdcUpsNumUnits.
An entry containing information applicable to a
particular input of UPS.
particular input of UPS.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
mdcUpsInputTableIndexmandatory
The UPS identifier.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.31.2.2.1.1.1 |
|
mdcUpsInputVoltagemandatory
The current utility line voltage in VAC.
|
RFC1155-SMIGauge Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.318.1.1.31.2.2.1.1.2 |
.1.3.6.1.4.1.318.1.1.31.2.3.1
·
1 row entry
·
5 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk mdcUpsOutputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::mdcUpsOutputTable'
A list of UPS output table entries. The number of entries is given by the value of mdcUpsNumUnits.
An entry containing information applicable to a
output of particular UPS.
output of particular UPS.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
mdcUpsOutputTableIndexmandatory
The UPS identifier.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.31.2.3.1.1.1 |
|
mdcUpsOutputVoltagemandatory
The output voltage of the UPS system in VAC.
|
RFC1155-SMIGauge Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.318.1.1.31.2.3.1.1.2 |
|
mdcUpsOutputCurrentmandatory
The current in amperes drawn by the load on the UPS.
|
RFC1155-SMIGauge Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.318.1.1.31.2.3.1.1.3 |
|
mdcUpsOutputActivePowermandatory
The total output active power of the UPS system in W.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.31.2.3.1.1.4 |
|
mdcUpsOutputFrequencymandatory
The current output frequency of the UPS system in Hz.
|
RFC1155-SMIGauge Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.318.1.1.31.2.3.1.1.5 |
.1.3.6.1.4.1.318.1.1.31.2.4.1
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk mdcUpsBatteryTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::mdcUpsBatteryTable'
Table of Battery details. The number of entries is given by the value of mdcUpsNumUnits.
An entry containing information applicable to
battery of individual UPS.
battery of individual UPS.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
mdcUpsBatteryTableIndexmandatory
The UPS identifier.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.31.2.4.1.1.1 |
|
mdcUpsBatteryRunTimeRemainingmandatory
The UPS battery run time remaining before battery
exhaustion. |
RFC1155-SMITimeTicks Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.318.1.1.31.2.4.1.1.2 |
|
mdcUpsBatteryCapacitymandatory
The remaining battery capacity expressed in
percent of full capacity. |
RFC1155-SMIGauge Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.318.1.1.31.2.4.1.1.3 |
.1.3.6.1.4.1.318.1.1.31.3.2.1
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk mdcCoolingStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::mdcCoolingStatusTable'
A list of cooling status table entries. The number of entries is given by the value of mdcCoolingNumUnits.
An entry containing information applicable to a
particular status of cooling unit.
particular status of cooling unit.
Indexes
| Column | Syntax | OID | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
mdcCoolingStatusTableIndexmandatory
The cooling unit identifier.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.31.3.2.1.1.1 |
||||||||||||||||
|
mdcCoolingStatusSupplyAirTempmandatory
The unit supply air temperature in degree Celsius.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.31.3.2.1.1.2 |
||||||||||||||||
|
mdcCoolingStatusReturnAirTempmandatory
The unit return air temperature in degree Celsius.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.31.3.2.1.1.3 |
||||||||||||||||
|
mdcCoolingStatusOperateModemandatory
The cooling unit operating mode.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.31.3.2.1.1.4 |
.1.3.6.1.4.1.318.1.1.31.3.3.4
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk mdcCoolingConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::mdcCoolingConfigTable'
A list of cooling configuration table entries. The number of entries is given by the value of mdcCoolingNumUnits.
An entry containing information applicable to
configuration of particular cooling unit.
configuration of particular cooling unit.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
mdcCoolingConfigTableIndexmandatory
The cooling unit identifier.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.31.3.3.4.1.1 |
||||||
|
mdcCoolingConfigOutletAirTempmandatory
Outlet air temperature set point. This OID represents the value sent to
the particular cooling unit in degree Celsius. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.31.3.3.4.1.2 |
||||||
|
mdcCoolingConfigPTCHeatermandatory
The status of PTC heater of particular cooling unit.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.31.3.3.4.1.3 |
||||||
|
mdcCoolingConfigCondensationpumpmandatory
The status of condensation pump of particular cooling unit.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.31.3.3.4.1.4 |
.1.3.6.1.4.1.318.1.1.31.5.2.1
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk mdcMeterStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::mdcMeterStatusTable'
A list of meter status table entries. The number of entries is given by the value of mdcMeterNumUnits.
An entry containing information applicable to a
particular status of meter.
particular status of meter.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
mdcMeterStatusTableIndexmandatory
The meter identifier.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.31.5.2.1.1.1 |
|
mdcMeterFrequencymandatory
The frequency in Hertz.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.31.5.2.1.1.2 |
|
mdcMeterVoltagemandatory
The voltage in Volts as measured by the meter.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.31.5.2.1.1.3 |
|
mdcMeterCurrentmandatory
The current in Amps as measured by the meter.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.31.5.2.1.1.4 |
|
mdcMeterActivePowermandatory
Shows the active power measured by the meter in hundreths of kW.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.31.5.2.1.1.5 |
|
mdcMeterApparentPowermandatory
Shows the apparent power measured by the meter in hundreths of kVA.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.31.5.2.1.1.6 |
.1.3.6.1.4.1.318.1.1.31.5.3.1
·
1 row entry
·
9 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk mdcMeterConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::mdcMeterConfigTable'
A list of meter configuration table entries. The number of entries is given by the value of mdcMeterNumUnits.
An entry containing information applicable to
configuration of particular meter.
configuration of particular meter.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
mdcMeterConfigTableIndexmandatory
The meter identifier.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.31.5.3.1.1.1 |
|
mdcMeterMinVoltThresholdmandatory
Threshold below which an input minimum voltage condition
will be generated. Specified as percent deviation from nominal voltage. |
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.318.1.1.31.5.3.1.1.2 |
|
mdcMeterLowVoltThresholdmandatory
Threshold below which an input low voltage condition
will be generated. Specified as percent deviation from nominal voltage. |
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.318.1.1.31.5.3.1.1.3 |
|
mdcMeterHighVoltThresholdmandatory
Threshold above which an input high voltage condition
will be generated. Specified as percent deviation from nominal voltage. |
Integer32r/w Constraints: range: 0-120 |
.1.3.6.1.4.1.318.1.1.31.5.3.1.1.4 |
|
mdcMeterMaxVoltThresholdmandatory
Threshold above which an input maximum voltage condition
will be generated. Specified as percent deviation from nominal voltage. |
Integer32r/w Constraints: range: 0-120 |
.1.3.6.1.4.1.318.1.1.31.5.3.1.1.5 |
|
mdcMeterMinCurrentThresholdmandatory
Threshold below which an input minimum current condition will be generated.
|
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.318.1.1.31.5.3.1.1.6 |
|
mdcMeterLowCurrentThresholdmandatory
Threshold below which an input low current condition will be generated.
|
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.318.1.1.31.5.3.1.1.7 |
|
mdcMeterHighCurrentThresholdmandatory
Threshold above which an input high current condition will be generated.
|
Integer32r/w Constraints: range: 0-110 |
.1.3.6.1.4.1.318.1.1.31.5.3.1.1.8 |
|
mdcMeterMaxCurrentThresholdmandatory
Threshold above which an input maximum current condition will be generated.
|
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.318.1.1.31.5.3.1.1.9 |
.1.3.6.1.4.1.318.1.1.33.2
·
1 row entry
·
14 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk ats5gDeviceIdentTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::ats5gDeviceIdentTable'
This table organizes the identifying data of devices in the device group.
This entry organizes the identity data of a single device.
Indexes
| Column | Syntax | OID | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
ats5gIdentDeviceIndexmandatory
This value is the data entry's index in the identity table.
|
Integer32 Constraints: range: 1-65535 |
.1.3.6.1.4.1.318.1.1.33.2.1.1 |
||||||||||||||||
|
ats5gIdentConfigModuleIDmandatory
This value is ID number that can be configured for each device. It cannot be
greater than the maximum number of devices in the network port sharing (NPS) group (32). Changing this value causes the device to reboot, whic… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.33.2.1.2 |
||||||||||||||||
|
ats5gIdentModuleTypemandatory
This value describes the role the specified device holds in the device group:
notNPS(1) specifies that the device is not in a group host(2) specifies that a device will broadcast firmware updates to guests guest(3) spec… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.33.2.1.3 |
||||||||||||||||
|
ats5gIdentModuleStatusmandatory
This value tracks the communication status of a device within the group.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.33.2.1.4 |
||||||||||||||||
|
ats5gIdentSerialNumbermandatory
This is the serial number of the automatic transfer switch.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.33.2.1.5 |
||||||||||||||||
|
ats5gIdentModelNumbermandatory
This is the model number of the automatic transfer switch.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.33.2.1.6 |
||||||||||||||||
|
ats5gIdentHardwareRevmandatory
This is the hardware revision of the automatic transfer switch.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.33.2.1.7 |
||||||||||||||||
|
ats5gIdentManufactureDatemandatory
This is the manufacture date of the automatic transfer switch.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.33.2.1.8 |
||||||||||||||||
|
ats5gIdentBootmonRevmandatory
This is the boot monitor firmware revision of the network management card.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.33.2.1.9 |
||||||||||||||||
|
ats5gIdentAOSRevmandatory
This is the operating system firmware revision of the network management card.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.33.2.1.10 |
||||||||||||||||
|
ats5gIdentAppRevmandatory
This is the application firmware revision of the network management card.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.33.2.1.11 |
||||||||||||||||
|
ats5gIdentConfigNamemandatory
This is the configurable name of the device. It may be up to 255 characters long.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.33.2.1.12 |
||||||||||||||||
|
ats5gIdentConfigLocationmandatory
This is the configurable location of the device. It may be up to 255 characters long.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.33.2.1.13 |
||||||||||||||||
|
ats5gIdentConfigContactmandatory
This is the configurable contact information of the device. It may be up to 255 characters long.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.1.33.2.1.14 |
.1.3.6.1.4.1.318.1.1.33.3
·
1 row entry
·
41 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk ats5gDeviceSwitchTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::ats5gDeviceSwitchTable'
This table organizes the data specific to the automatic transfer switch.
This entry organizes the switch data of a single device.
Indexes
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
ats5gSwitchDeviceIndexmandatory
This value is the data entry's index in the switching table.
|
Integer32 Constraints: range: 1-65535 |
.1.3.6.1.4.1.318.1.1.33.3.1.1 |
||||||||||
|
ats5gSwitchModuleIDmandatory
This value is the ats5gIdentConfigModuleID of the device being queried.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.33.3.1.2 |
||||||||||
|
ats5gSwitchOrientationmandatory
This value describes the voltage orientation of the ATS.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.33.3.1.3 |
||||||||||
|
ats5gSwitchCumulativeAlarmStatusmandatory
This is the severity of the most severe alarm currently active.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.33.3.1.4 |
||||||||||
|
ats5gSwitchCommunicationStatusmandatory
This is the communication status between the network management card
and the automatic transfer switch. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.33.3.1.5 |
||||||||||
|
ats5gSwitchConfigFrontPanelLockoutmandatory
This is the configurable lockout status of the source preference toggle button
on the front panel. The button does nothing while the front panel is locked. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.33.3.1.6 |
||||||||||
|
ats5gSwitchConfigPreferredSourcemandatory
This is the configurable source preference. If the ATS is fully redundant the
preferred source will be the selected source. If the preferred source is none(3), the ATS will switch sources only in response to measured ch… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.33.3.1.7 |
||||||||||
|
ats5gSwitchSelectedSourcemandatory
This is the selected source that will be used to power downstream devices.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.33.3.1.8 |
||||||||||
|
ats5gSwitchRedundancyStatemandatory
This is the ATS redundancy status. While this value is atsFullyRedundant(2),
either input may be used to power downstream devices. While this value is atsRedundancyLost(1), one input has failed validation and downstream… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.33.3.1.9 |
||||||||||
|
ats5gSwitchSourceAStatusmandatory
This is the input status of source A. The ATS will use source B as the selected source
while this value is fail(1). |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.33.3.1.10 |
||||||||||
|
ats5gSwitchSourceBStatusmandatory
This is the input status of source B. The ATS will use source A as the selected source
while this value is fail(1). |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.33.3.1.11 |
||||||||||
|
ats5gSwitchRatedVoltagemandatory
This is the default nominal line VRMS in volts (V) for this unit.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.33.3.1.12 |
||||||||||
|
ats5gSwitchConfigNominalVoltagemandatory
This is the configurable line VRMS in volts (V) that will be used to select sources.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.33.3.1.13 |
||||||||||
|
This value specifies which voltage transfer range should be used to disqualify
sources and raise alarms. The narrow transfer voltage must be less than the medium transfer voltage, which must be less than the wide transf… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.33.3.1.14 |
||||||||||
|
ats5gSwitchConfigTransferVoltageWidemandatory
This is the configurable transfer range in volts (V) used to disqualify sources when
ats5gSwitchConfigTransferVoltageRange is wide(1). |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.33.3.1.15 |
||||||||||
|
This is the configurable transfer range in volts (V) used to disqualify sources when
ats5gSwitchConfigTransferVoltageRange is medium(2). |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.33.3.1.16 |
||||||||||
|
This is the configurable transfer range in volts (V) used to disqualify sources when
ats5gSwitchConfigTransferVoltageRange is narrow(3). |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.33.3.1.17 |
||||||||||
|
ats5gSwitchConfigVoltageSensitivitymandatory
This is the configured sensitivity threshold for rapid changes to input voltage.
It is recommended to use high(1) unless frequent small changes are expected. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.33.3.1.18 |
||||||||||
|
ats5gSwitchSourceAVoltagemandatory
This is the measured line VRMS of source A reported in volts (V).
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.33.3.1.19 |
||||||||||
|
ats5gSwitchSourceBVoltagemandatory
This is the measured line VRMS of source B reported in volts (V).
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.33.3.1.20 |
||||||||||
|
ats5gSwitchRatedFrequencymandatory
This is the default nominal line frequency for this unit reported in Hertz (Hz).
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.33.3.1.21 |
||||||||||
|
ats5gSwitchConfigNominalFrequencymandatory
This is the configurable line frequency in Hertz (Hz) that will be used to select
sources. If the difference between ats5gSwitchConfigNominalFrequency and a source's measured frequency is greater than ats5gSwitchConfigF… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.33.3.1.22 |
||||||||||
|
ats5gSwitchConfigFrequencyDeviationmandatory
This is the configurable frequency deviation in Hertz (Hz) that will be used to select
sources. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.33.3.1.23 |
||||||||||
|
ats5gSwitchSourceAFrequencymandatory
This is the measured line frequency of source A reported in Hertz (Hz).
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.33.3.1.24 |
||||||||||
|
ats5gSwitchSourceBFrequencymandatory
This is the measured line frequency of source B reported in Hertz (Hz).
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.33.3.1.25 |
||||||||||
|
ats5gSwitchEventCountStartTimemandatory
This value is the time and date of the last event count reset action.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.33.3.1.26 |
||||||||||
|
ats5gSwitchEventCountRedundancyLossmandatory
This value tracks the number of redundancy loss events. It increments each time
a source becomes invalid. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.33.3.1.27 |
||||||||||
|
ats5gSwitchEventCountSourceSwitchmandatory
This value tracks the number of source switch events. It increments each time the
selected source changes. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.33.3.1.28 |
||||||||||
|
This value tracks the number of preferred source configuration change events.
It increments each time the user updates their source preference. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.33.3.1.29 |
||||||||||
|
ats5gSwitchEventCountSpikeOrDropmandatory
This value tracks voltage spike and drop events. It increments each time a
source's measured instantaneous voltage increases or decreases rapidly. This depends on configured voltage sensitivity. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.33.3.1.30 |
||||||||||
|
ats5gSwitchEventCountSurgeOrDroopmandatory
This value tracks voltage surge or droop events. It increments each time a
source's calculated VRMS increases or decreases rapidly. This does not depend on any user configurations. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.33.3.1.31 |
||||||||||
|
ats5gSwitchEventCountFreqOutOfRangemandatory
This value tracks frequency threshold violations. It increments each time a source
is disqualified because the difference between its measured frequency and the configured nominal frequency is greater than the configure… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.33.3.1.32 |
||||||||||
|
ats5gSwitchControlEventCountResetmandatory
This control resets the event counts when the value is set to reset(2).
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.33.3.1.33 |
||||||||||
|
ats5gSwitchVoltageOutStatusmandatory
This value is on(2) while the output outlets are powered.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.33.3.1.34 |
||||||||||
|
ats5gSwitchOverCurrentStatemandatory
This value is atsOverCurrent(1) when the ATS has exceeded the output
current threshold and will not allow a switch over to the alternate power source if the current source fails. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.33.3.1.35 |
||||||||||
|
ats5gSwitchPhaseSyncStatusmandatory
This value tracks the phase sync status.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.33.3.1.36 |
||||||||||
|
ats5gSwitchSourceA24VSupplyStatusmandatory
This value tracks the internal source A 24VDC power supply status.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.33.3.1.37 |
||||||||||
|
ats5gSwitchSourceB24VSupplyStatusmandatory
This value tracks the internal source B 24VDC power supply status.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.33.3.1.38 |
||||||||||
|
ats5gSwitchSourceA48VSupplyStatusmandatory
This value tracks the internal source A 48VDC power supply status.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.33.3.1.39 |
||||||||||
|
ats5gSwitchSourceB48VSupplyStatusmandatory
This value tracks the internal source B 48VDC power supply status.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.33.3.1.40 |
||||||||||
|
ats5gSwitch3p3VSupplyStatusmandatory
This value tracks the internal 3.3VDC power supply status.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.33.3.1.41 |
.1.3.6.1.4.1.318.1.1.33.4
·
1 row entry
·
18 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk ats5gDeviceEnvironmentTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::ats5gDeviceEnvironmentTable'
This table organizes the data specific to the environment monitoring accessories.
This entry organizes the switch data of a single device.
Indexes
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
ats5gEnvDeviceIndexmandatory
This value is the data entry's index in the environment table.
|
Integer32 Constraints: range: 1-65535 |
.1.3.6.1.4.1.318.1.1.33.4.1.1 |
||||||||||
|
ats5gEnvModuleIDmandatory
This value is the ats5gIdentConfigModuleID of the device being queried.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.33.4.1.2 |
||||||||||
|
ats5gEnvSensorTypemandatory
This value is the type of the currently attached sensor accessory.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.33.4.1.3 |
||||||||||
|
ats5gEnvAlarmStatusmandatory
This is the severity of the most severe environment-specific alarm currently active.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.33.4.1.4 |
||||||||||
|
ats5gEnvTemperaturemandatory
This is the measured temperature of the attached sensor reported in tenth-degrees
Fahrenheit. The value reports as -1 if the attached sensor does not support temperature measurements. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.33.4.1.5 |
||||||||||
|
ats5gEnvConfigTempMaxThresholdmandatory
This is the configured maximum temperature threshold reported in degrees Fahrenheit.
The value reports as -1 if the attached sensor does not support temperature measurements. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.33.4.1.6 |
||||||||||
|
ats5gEnvConfigTempHighThresholdmandatory
This is the configured high temperature threshold reported in degrees Fahrenheit.
The value reports as -1 if the attached sensor does not support temperature measurements. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.33.4.1.7 |
||||||||||
|
ats5gEnvConfigTempHysteresismandatory
This is the configured temperature threshold hysteresis reported in degrees Fahrenheit.
The value reports as -1 if the attached sensor does not support temperature measurements. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.33.4.1.8 |
||||||||||
|
ats5gEnvConfigTempAlarmsEnabledmandatory
This is the configured temperature monitoring status. While this value is disabled(1),
no temperature-related alarms will be active. The value reports as -1 if the attached sensor does not support temperature measuremen… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.33.4.1.9 |
||||||||||
|
ats5gEnvHumiditymandatory
This is the measured humidity around the attached sensor reported in percent relative
humidity. The value reports as -1 if the attached sensor does not support humidity measurements. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.33.4.1.10 |
||||||||||
|
ats5gEnvConfigHumLowThresholdmandatory
This is the configured low humidity threshold reported in %RH. The value reports as -1
if the attached sensor does not support humidity measurements. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.33.4.1.11 |
||||||||||
|
ats5gEnvConfigHumMinThresholdmandatory
This is the configured minimum humidity threshold reported in %RH. The value reports
as -1 if the attached sensor does not support humidity measurements. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.33.4.1.12 |
||||||||||
|
ats5gEnvConfigHumHysteresismandatory
This is the configured humidity threshold hysteresis reported in %RH. The value reports
as -1 if the attached sensor does not support humidity measurements. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.33.4.1.13 |
||||||||||
|
ats5gEnvConfigHumAlarmsEnabledmandatory
This is the configured humidity monitoring status. While this value is disabled(1),
no humidity-related alarms will be active. The value reports as -1 if the attached sensor does not support humidity measurements. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.33.4.1.14 |
||||||||||
|
ats5gEnvPeakTemperaturemandatory
This is the highest temperature recorded since the last peak temperature reset,
reported in degrees Fahrenheit. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.33.4.1.15 |
||||||||||
|
ats5gEnvPeakTempTimemandatory
This is the date and time that the peak temperature was recorded.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.33.4.1.16 |
||||||||||
|
ats5gEnvPeakTempResetTimemandatory
This is the date and time that the peak temperature was last reset.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.33.4.1.17 |
||||||||||
|
ats5gEnvControlPeakTempResetmandatory
This control resets the peak temperature when the value is set to reset(2).
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.33.4.1.18 |
.1.3.6.1.4.1.318.1.1.33.6
·
1 row entry
·
10 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk ats5gBankTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::ats5gBankTable'
This table organizes the bank data of devices in the device group.
This entry organizes the bank data of a single device.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
ats5gBankIndexmandatory
This value is the data entry's index in the bank table.
|
Integer32 Constraints: range: 1-65535 |
.1.3.6.1.4.1.318.1.1.33.6.1.1 |
||||||||
|
ats5gBankModuleIDmandatory
This value is the ats5gIdentConfigModuleID of the device being queried.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.33.6.1.2 |
||||||||
|
ats5gBankTypemandatory
This value describes the type of bank associated with this bank index. If a device
has multiple banks, then its total(1) output will include the bank1(2) and bank2(3) outputs. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.33.6.1.3 |
||||||||
|
ats5gBankRatedAmpsmandatory
This value is the rated output of the specified bank reported in amps (A).
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.33.6.1.4 |
||||||||
|
ats5gBankOutputTenthAmpsmandatory
This value is the measured output of the specified bank reported in tenths of amps (A).
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.33.6.1.5 |
||||||||
|
ats5gBankConfigLowLoadThresholdmandatory
This value is the configured low load threshold of the specified bank reported
in amps (A). |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.33.6.1.6 |
||||||||
|
ats5gBankConfigNearOverLoadThresholdmandatory
This value is the configured near overload threshold of the specified bank reported
in amps (A). |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.33.6.1.7 |
||||||||
|
ats5gBankConfigOverloadThresholdmandatory
This value is the configured overload threshold of the specified bank reported
in amps (A). |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.33.6.1.8 |
||||||||
|
ats5gBankApparentPowermandatory
This value is the calculated apparent power of the specified bank reported
in kilovolt-amps (kVA). |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.1.33.6.1.9 |
||||||||
|
ats5gBankOutputCurrentStatusmandatory
This value tracks the load status of the specified bank.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.1.1.33.6.1.10 |
.1.3.6.1.4.1.318.1.2.1.2.2
·
1 row entry
·
4 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk powerNetSoftwareTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::powerNetSoftwareTable'
A list of the software monitoring the UPS.
An entry containing information on a software module.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
moduleNumbermandatory
The index into the Software Entry Table
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.2.1.2.2.1.1 |
|
moduleNamemandatory
The name of the software module.
|
OctetString Constraints: range: 0-79 |
.1.3.6.1.4.1.318.1.2.1.2.2.1.2 |
|
moduleVersionmandatory
The version of the software module.
|
OctetString Constraints: range: 0-8 |
.1.3.6.1.4.1.318.1.2.1.2.2.1.3 |
|
moduleDatemandatory
The date of the software module represented as mm-dd-yy.
|
OctetString Constraints: range: 0-9 |
.1.3.6.1.4.1.318.1.2.1.2.2.1.4 |
.1.3.6.1.4.1.318.1.2.3.3.4
·
1 row entry
·
3 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk pcnsNmcTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::pcnsNmcTable'
The Network Management Cards in the UPS devices, which PCNS is monitoring to provide safe shutdown.
Details of the NMC.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
pcnsNmcIndexmandatory
Index of the NMC within PCNS setup.
|
RFC1155-SMIGauge Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.318.1.2.3.3.4.1.1 |
|
pcnsNmcAddrmandatory
The IP address of the NMC.
|
RFC1155-SMIIpAddress Type Constraints: range: 4 |
.1.3.6.1.4.1.318.1.2.3.3.4.1.2 |
|
pcnsNmcOutletmandatory
The Outlet Group which PCNS is enrolled with on the NMC.
|
RFC1155-SMIGauge Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.318.1.2.3.3.4.1.3 |
.1.3.6.1.4.1.318.1.2.3.5.9
·
1 row entry
·
11 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk pcnsAdvancedShutdownTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::pcnsAdvancedShutdownTable'
The Network Management Cards in the UPS devices, which PCNS is monitoring to provide safe shutdown.
Details of the NMC.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
pcnsAdvancedGroupNomandatory
Index of the Advanced Shutdown Group.
|
RFC1155-SMIGauge Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.318.1.2.3.5.9.1.1 |
||||
|
pcnsAdvancedGroupNamemandatory
Name of the Advanced Shutdown Group.
|
OctetStringr/w Constraints: range: 0-32 |
.1.3.6.1.4.1.318.1.2.3.5.9.1.2 |
||||
|
pcnsAdvancedGroupNMCmandatory
List of NMCs in the Advanced Shutdown Group.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.2.3.5.9.1.3 |
||||
|
Number of UPS devices required to power load.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.2.3.5.9.1.4 |
||||
|
Run a shutdown command file before performing graceful shutdown.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.2.3.5.9.1.5 |
||||
|
pcnsAdvancedShutdownCommandFilemandatory
Full name of the shutdown command file to run before graceful shutdown.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.1.2.3.5.9.1.6 |
||||
|
How long in seconds shutdown command file takes to run.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.1.2.3.5.9.1.7 |
||||
|
pcnsAdvancedShutdownPowerchuteServermandatory
Shut down PowerChute Server.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.2.3.5.9.1.8 |
||||
|
pcnsAdvancedShutdownOnLostRedundancymandatory
Shut down if Redundancy lost.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.2.3.5.9.1.9 |
||||
|
pcnsAdvancedTurnOffUpsmandatory
Turn off the UPS when performing a graceful shutdown.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.2.3.5.9.1.10 |
||||
|
pcnsAdvancedTurnOffSOGmandatory
Turn off the Outlet Group on the UPS when performing a graceful shutdown.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.1.2.3.5.9.1.11 |
.1.3.6.1.4.1.318.2.1.2
·
1 row entry
·
6 columns
Uses the apc variant from
Command help
/opt/observium/mibs/apc.
Walk mconfigTrapReceiverTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-MIB' -M '/opt/observium/mibs/apc:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-MIB::mconfigTrapReceiverTable'
A list of managers to send traps to. The number of entries is given by the value of mconfigNumTrapReceivers.
The managers to send traps to.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
trapIndexmandatory
The index to a trap receiver entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.318.2.1.2.1.1 |
||||||
|
receiverAddrmandatory
The IP address of the manager to send a trap to.
|
RFC1155-SMIIpAddressr/w Type Constraints: range: 4 |
.1.3.6.1.4.1.318.2.1.2.1.2 |
||||||
|
communityStringmandatory
The community name to use in the trap when
sent to the manager. |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.318.2.1.2.1.3 |
||||||
|
severityobsolete
The severity threshold of traps to send to the manager.
traps are labeled in severity as informational(1), warning(2), severe(3). Only traps of equal or greater severity than this value are sent to the manager. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.2.1.2.1.4 |
||||||
|
acceptThisReceivermandatory
The value of yes(1) indicates that trap generation for this manager is enabled.
The value of no(2) indicates that trap generation for this manager is disabled |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.318.2.1.2.1.5 |
||||||
|
receiveTrapTypeobsolete
Type of trap.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.318.2.1.2.1.6 |