PowerNet-Inova Table View
Table-centric layout grouping table, row, and column objects.
Tables
28
Rows
28
Columns
252
.1.3.6.1.4.1.63131.1.1.26.2
·
1 row entry
·
13 columns
Uses the inova variant from
Command help
/opt/observium/mibs/inova.
Walk rPDU2IdentTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-Inova' -M '/opt/observium/mibs/inova:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-Inova::rPDU2IdentTable'
A table of Rack PDU identification data
Identification data from Rack PDU being queried
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2IdentIndexmandatory
The index to the Rack PDU identification table
entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.2.1.1 |
|
rPDU2IdentModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.2.1.2 |
|
rPDU2IdentNamemandatory
A user-defined string identifying the Rack PDU
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.63131.1.1.26.2.1.3 |
|
rPDU2IdentLocationmandatory
A user-defined string identifying the location
of the Rack PDU |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.63131.1.1.26.2.1.4 |
|
rPDU2IdentHardwareRevmandatory
The Rack PDU hardware version
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.63131.1.1.26.2.1.5 |
|
rPDU2IdentFirmwareRevmandatory
The Rack PDU firmware version
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.63131.1.1.26.2.1.6 |
|
rPDU2IdentDateOfManufacturemandatory
The date the Rack PDU was manufactured
in mm/dd/yyyy format |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.63131.1.1.26.2.1.7 |
|
rPDU2IdentModelNumbermandatory
The Rack PDU model number
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.63131.1.1.26.2.1.8 |
|
rPDU2IdentSerialNumbermandatory
The Rack PDU serial number
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.63131.1.1.26.2.1.9 |
|
rPDU2IdentContactmandatory
A user-defined string identifying the
person to contact regarding the Rack PDU |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.63131.1.1.26.2.1.10 |
|
rPDU2IdentBootMonitorRevmandatory
The Rack PDU Boot Monitor version
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.63131.1.1.26.2.1.11 |
|
rPDU2IdentLongDescriptionmandatory
The Rack PDU Long Description name
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.63131.1.1.26.2.1.12 |
|
rPDU2IdentNMCSerialNumbermandatory
The Rack PDU Network Management Card (NMC) serial number
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.63131.1.1.26.2.1.13 |
.1.3.6.1.4.1.63131.1.1.26.4.1
·
1 row entry
·
14 columns
Uses the inova variant from
Command help
/opt/observium/mibs/inova.
Walk rPDU2DeviceConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-Inova' -M '/opt/observium/mibs/inova:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-Inova::rPDU2DeviceConfigTable'
A table of Rack PDU configuration data
Configuration data from Rack PDU being queried
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2DeviceConfigIndexmandatory
The index to the Rack PDU table entry
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.1.1.1 |
|
rPDU2DeviceConfigModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.1.1.2 |
|
rPDU2DeviceConfigNamemandatory
A user-defined string identifying the Rack PDU
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.63131.1.1.26.4.1.1.3 |
|
rPDU2DeviceConfigLocationmandatory
A user-defined string identifying the location
of the Rack PDU |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.63131.1.1.26.4.1.1.4 |
|
rPDU2DeviceConfigDisplayOrientationmandatory
Indicates the intended physical orientation
of the display. displayNormal(1) indicates normal orientation displayReverse(2) indicates upside down orientation |
Enumerationr/w | .1.3.6.1.4.1.63131.1.1.26.4.1.1.5 |
|
rPDU2DeviceConfigColdstartDelaymandatory
The amount of delay, measured in seconds, between
when power is provided to the Rack PDU and when the Rack PDU provides basic master power to the outlets. Allowed values are: -1 - never apply power automatically. … |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.1.1.6 |
|
User-defined low power draw alarm threshold,
measured in tenths of kilowatts. Models that do not support this feature will respond to this OID with a value of -1. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.1.1.7 |
|
User-defined near power overload threshold,
measured in tenths of kilowatts. Models that do not support this feature will respond to this OID with a value of -1. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.1.1.8 |
|
User-defined power overload threshold,
measured in tenths of kilowatts. Models that do not support this feature will respond to this OID with a value of -1. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.1.1.9 |
|
Setting this OID to reset (2) will cause the existing peak power value
to be replaced by the current load power value. Getting this OID will do nothing and return the noOperation(1) value. Models that do … |
Enumerationr/w | .1.3.6.1.4.1.63131.1.1.26.4.1.1.10 |
|
rPDU2DeviceConfigDeviceEnergyResetmandatory
Setting this OID to reset (2) will cause the device energy meter value
to be reset to zero. Getting this OID in models that support this feature will do nothing and return the noOperation(1) value. … |
Enumerationr/w | .1.3.6.1.4.1.63131.1.1.26.4.1.1.11 |
|
rPDU2DeviceConfigOutletsEnergyResetmandatory
Setting this OID to reset (2) will cause the all outlet energy meter values
to be reset to zero. Getting this OID will do nothing and return the noOperation(1) value. Models that do not sup… |
Enumerationr/w | .1.3.6.1.4.1.63131.1.1.26.4.1.1.12 |
|
Setting this OID to reset (2) will cause the all outlet peak load values
to be reset to zero. Getting this OID will do nothing and return the noOperation(1) value. Models that do not suppor… |
Enumerationr/w | .1.3.6.1.4.1.63131.1.1.26.4.1.1.13 |
|
rPDU2DeviceConfigContactmandatory
A user-defined string identifying the
person to contact regarding the Rack PDU |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.63131.1.1.26.4.1.1.14 |
.1.3.6.1.4.1.63131.1.1.26.4.2
·
1 row entry
·
13 columns
Uses the inova variant from
Command help
/opt/observium/mibs/inova.
Walk rPDU2DevicePropertiesTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-Inova' -M '/opt/observium/mibs/inova:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-Inova::rPDU2DevicePropertiesTable'
A table of Rack PDU properties
Properties of the Rack PDU being queried
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2DevicePropertiesIndexmandatory
The index to the Rack PDU properties table entry
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.2.1.1 |
|
rPDU2DevicePropertiesModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.2.1.2 |
|
rPDU2DevicePropertiesNamemandatory
A user-defined string identifying the Rack PDU
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.63131.1.1.26.4.2.1.3 |
|
rPDU2DevicePropertiesNumOutletsmandatory
The number of outlets on the Rack PDU
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.2.1.4 |
|
The number of switched outlets on the Rack PDU
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.2.1.5 |
|
The number of metered outlets on the Rack PDU
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.2.1.6 |
|
rPDU2DevicePropertiesNumPhasesmandatory
The number of phases present in the Rack PDU
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.2.1.7 |
|
rPDU2DevicePropertiesNumMeteredBanksmandatory
The number of metered banks present in the Rack PDU
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.2.1.8 |
|
The maximum current rating, measured in Amps, for
the Rack PDU |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.2.1.9 |
|
rPDU2DevicePropertiesOrientationmandatory
Rack PDU orientation
|
Enumeration | .1.3.6.1.4.1.63131.1.1.26.4.2.1.10 |
|
rPDU2DevicePropertiesOutletLayoutmandatory
Getting this OID will return outlet layout for the device.
seqPhaseToNeutral(1) indicates outlet layout as follows: 1:1-N,2:2-N,3:3-N,4:1-N,5:2-N,... or for single phase SKUs, all outlets 1-N … |
Enumeration | .1.3.6.1.4.1.63131.1.1.26.4.2.1.11 |
|
The maximum current rating, measured in Amps, for
the Rack PDU |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.2.1.12 |
|
The maximum power rating, measured in tenths of kilowatts, for
the Rack PDU |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.2.1.13 |
.1.3.6.1.4.1.63131.1.1.26.4.3
·
1 row entry
·
20 columns
Uses the inova variant from
Command help
/opt/observium/mibs/inova.
Walk rPDU2DeviceStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-Inova' -M '/opt/observium/mibs/inova:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-Inova::rPDU2DeviceStatusTable'
A table of Rack PDU status information
Status information from the Rack PDU being queried
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2DeviceStatusIndexmandatory
The index to the Rack PDU status table entry
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.3.1.1 |
|
rPDU2DeviceStatusModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.3.1.2 |
|
rPDU2DeviceStatusNamemandatory
A user-defined string identifying the Rack PDU
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.63131.1.1.26.4.3.1.3 |
|
rPDU2DeviceStatusLoadStatemandatory
Indicates the present load status of the Rack PDU.
Models that do not support this feature will respond to this OID with a value of notsupported (5). |
Enumeration | .1.3.6.1.4.1.63131.1.1.26.4.3.1.4 |
|
rPDU2DeviceStatusPowermandatory
The power consumption of the Rack PDU load in hundredths of kilowatts.
Models that do not support this feature will respond to this OID with a value of -1. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.3.1.5 |
|
rPDU2DeviceStatusPeakPowermandatory
The peak power consumption of the Rack PDU load in hundredths of kilowatts.
Models that do not support this feature will respond to this OID with a value of -1. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.3.1.6 |
|
rPDU2DeviceStatusPeakPowerTimestampmandatory
Indicates the date and time that peak power consumption occurred.
Models that do not support this feature will respond to this OID with string 'notsupported'. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.63131.1.1.26.4.3.1.7 |
|
rPDU2DeviceStatusPeakPowerStartTimemandatory
Indicates the date and time of the last device peak power reset.
Models that do not support this feature will respond to this OID with string 'notsupported'. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.63131.1.1.26.4.3.1.8 |
|
rPDU2DeviceStatusEnergymandatory
A user resettable energy meter measuring Rack PDU load
energy consumption in tenths of kilowatt-hours. Models that do not support this feature will respond to this OID with a value of -1. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.3.1.9 |
|
rPDU2DeviceStatusEnergyStartTimemandatory
Indicates the date and time of the last device energy
meter reset. Models that do not support this feature will respond to this OID with string 'notsupported'. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.63131.1.1.26.4.3.1.10 |
|
rPDU2DeviceStatusCommandPendingmandatory
Indicates whether or not the device
is processing a pending command. If the commandPendingUnknown (3) value is returned, all devices powered by the Rack PDU should be shut down. The Rack PDU's power should then be cyc… |
Enumeration | .1.3.6.1.4.1.63131.1.1.26.4.3.1.11 |
|
rPDU2DeviceStatusPowerSupplyAlarmmandatory
Indicates a power supply alarm is active when value
equals alarm (2) |
Enumeration | .1.3.6.1.4.1.63131.1.1.26.4.3.1.12 |
|
rPDU2DeviceStatusPowerSupply1Statusmandatory
Indicates whether or not an alarm is active in Power
Supply 1 |
Enumeration | .1.3.6.1.4.1.63131.1.1.26.4.3.1.13 |
|
rPDU2DeviceStatusPowerSupply2Statusmandatory
Indicates whether or not an alarm is active in Power
Supply 2 |
Enumeration | .1.3.6.1.4.1.63131.1.1.26.4.3.1.14 |
|
Indicates the date and time of the last outlets energy
meter reset. Models that do not support this feature will respond to this OID with string 'notsupported'. |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.63131.1.1.26.4.3.1.15 |
|
rPDU2DeviceStatusApparentPowermandatory
The apparent power consumption of the Rack PDU load in hundredths of kiloVoltAmps (kVA).
Models that do not support this feature will respond to this OID with a value of -1. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.3.1.16 |
|
rPDU2DeviceStatusPowerFactormandatory
The power factor of the Rack PDU load in hundredths. Models that do not support this feature
will respond to this OID with a value of -1. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.3.1.17 |
|
rPDU2DeviceStatusNPSTypemandatory
The device NPS status:
notNPS (1) indicates the Rack PDU is not in an NPS group. host (2) indicates the Rack PDU has been designated as a host in an NPS group. Only one Rack PDU in an NPS group is allowed to be the ho… |
Enumeration | .1.3.6.1.4.1.63131.1.1.26.4.3.1.18 |
|
rPDU2DeviceStatusResidualPowermandatory
The measured device residual power from the PDU meters in hundredths of kiloVoltAmps.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.3.1.19 |
|
rPDU2DeviceStatusFrequencymandatory
The measured device frequency from the PDU meters in tenths of Hz.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.3.1.20 |
.1.3.6.1.4.1.63131.1.1.26.4.4
·
1 row entry
·
4 columns
Uses the inova variant from
Command help
/opt/observium/mibs/inova.
Walk rPDU2DeviceControlTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-Inova' -M '/opt/observium/mibs/inova:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-Inova::rPDU2DeviceControlTable'
A table of Rack PDU control data
Control data from Rack PDU being queried
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2DeviceControlIndexmandatory
The index to the Rack PDU control table entry
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.4.1.1 |
|
rPDU2DeviceControlModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.4.4.1.2 |
|
rPDU2DeviceControlNamemandatory
A user-defined string identifying the Rack PDU
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.63131.1.1.26.4.4.1.3 |
|
rPDU2DeviceControlCommandmandatory
Setting this OID to immediateAllOn (1) will turn all outlets
on immediately. Setting this OID to delayedAllOn (2) will turn all outlets on as defined by each outlet's rPDU2OutletSwitchedConfigPowerOnTime … |
Enumerationr/w | .1.3.6.1.4.1.63131.1.1.26.4.4.1.4 |
.1.3.6.1.4.1.63131.1.1.26.6.1
·
1 row entry
·
8 columns
Uses the inova variant from
Command help
/opt/observium/mibs/inova.
Walk rPDU2PhaseConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-Inova' -M '/opt/observium/mibs/inova:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-Inova::rPDU2PhaseConfigTable'
A table of Rack PDU phase configuration data
Configuration data from currently queried Rack
PDU phase
PDU phase
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2PhaseConfigIndexmandatory
The index to the Rack PDU phase configuration
table entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.1.1.1 |
|
rPDU2PhaseConfigModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.1.1.2 |
|
rPDU2PhaseConfigNumbermandatory
The numeric phase ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.1.1.3 |
|
rPDU2PhaseConfigOverloadRestrictionmandatory
This OID controls the behavior of a Switched Rack PDU
phase when an overload condition is possible and additional outlets are requested to be turned on. Setting this OID to alwaysAllowTurnON (1) will alwa… |
Enumerationr/w | .1.3.6.1.4.1.63131.1.1.26.6.1.1.4 |
|
User-defined low load phase current
threshold in Amps |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.1.1.5 |
|
User-defined near phase overload warning
threshold in Amps |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.1.1.6 |
|
User-defined phase overload current
threshold in Amps |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.1.1.7 |
|
Setting this OID to reset (2) will cause the existing peak current value
to be replaced by the present load current value. Getting this OID will do nothing and return the noOperation(1) value. |
Enumerationr/w | .1.3.6.1.4.1.63131.1.1.26.6.1.1.8 |
.1.3.6.1.4.1.63131.1.1.26.6.2
·
1 row entry
·
3 columns
Uses the inova variant from
Command help
/opt/observium/mibs/inova.
Walk rPDU2PhasePropertiesTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-Inova' -M '/opt/observium/mibs/inova:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-Inova::rPDU2PhasePropertiesTable'
A table of Rack PDU phase properties
Properties of the currently queried Rack
PDU phase
PDU phase
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2PhasePropertiesIndexmandatory
The index to the Rack PDU phase properties
table entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.2.1.1 |
|
rPDU2PhasePropertiesModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.2.1.2 |
|
rPDU2PhasePropertiesNumbermandatory
The numeric phase ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.2.1.3 |
.1.3.6.1.4.1.63131.1.1.26.6.3
·
1 row entry
·
14 columns
Uses the inova variant from
Command help
/opt/observium/mibs/inova.
Walk rPDU2PhaseStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-Inova' -M '/opt/observium/mibs/inova:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-Inova::rPDU2PhaseStatusTable'
A table of Rack PDU phase status data
Status data from currently queried Rack PDU
phase
phase
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2PhaseStatusIndexmandatory
The index to the Rack PDU phase status table
entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.3.1.1 |
|
rPDU2PhaseStatusModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.3.1.2 |
|
rPDU2PhaseStatusNumbermandatory
The numeric phase ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.3.1.3 |
|
rPDU2PhaseStatusLoadStatemandatory
Indicates the present load status of the Rack PDU
phase being queried |
Enumeration | .1.3.6.1.4.1.63131.1.1.26.6.3.1.4 |
|
rPDU2PhaseStatusCurrentmandatory
Indicates the current draw, in tenths of Amps, of the load
on the Rack PDU phase being queried |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.3.1.5 |
|
rPDU2PhaseStatusVoltagemandatory
Indicates the Voltage, in Volts, of the Rack
PDU phase being queried. Models that do not support this feature will respond to this OID with a value of -1. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.3.1.6 |
|
rPDU2PhaseStatusPowermandatory
Indicates the load power, in hundredths of kilowatts (kW),
consumed on the Rack PDU phase being queried. Models that do not support this feature will respond to this OID with a value of -1. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.3.1.7 |
|
rPDU2PhaseStatusApparentPowermandatory
Indicates the load apparent power, in hundredths of kiloVoltAmps (kVA),
consumed on the Rack PDU phase being queried. Models that do not support this feature will respond to this OID with a value of -1. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.3.1.8 |
|
rPDU2PhaseStatusPowerFactormandatory
Indicates the load power factor, in hundredths,
of the Rack PDU phase being queried. Models that do not support this feature will respond to this OID with a value of -1. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.3.1.9 |
|
rPDU2PhaseStatusPeakCurrentmandatory
The peak current of the Rack PDU phase load in tenths of Amps
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.3.1.10 |
|
rPDU2PhaseStatusPeakCurrentTimestampmandatory
Indicates the date and time that the peak current occurred
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.63131.1.1.26.6.3.1.11 |
|
rPDU2PhaseStatusPeakCurrentStartTimemandatory
Indicates the date and time of the last phase peak current reset
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.63131.1.1.26.6.3.1.12 |
|
rPDU2PhaseStatusEnergymandatory
A user resettable energy meter measuring Rack PDU phase load
energy consumption in tenths of kilowatt-hours. Models that do not support this feature will respond to this OID with a value of -1. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.6.3.1.13 |
|
rPDU2PhaseStatusBreakermandatory
Phase breaker status.
|
Enumeration | .1.3.6.1.4.1.63131.1.1.26.6.3.1.14 |
.1.3.6.1.4.1.63131.1.1.26.8.1
·
1 row entry
·
8 columns
Uses the inova variant from
Command help
/opt/observium/mibs/inova.
Walk rPDU2BankConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-Inova' -M '/opt/observium/mibs/inova:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-Inova::rPDU2BankConfigTable'
A table of Rack PDU bank configuration data
Configuration data from currently queried
Rack PDU bank
Rack PDU bank
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2BankConfigIndexmandatory
The index to the Rack PDU bank configuration
table entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.8.1.1.1 |
|
rPDU2BankConfigModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.8.1.1.2 |
|
rPDU2BankConfigNumbermandatory
The numeric bank ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.8.1.1.3 |
|
rPDU2BankConfigOverloadRestrictionmandatory
This OID controls the behavior of a Switched Rack PDU
bank when an overload condition is possible and additional outlets are requested to be turned on. Setting this OID to alwaysAllowTurnON (1) will alway… |
Enumerationr/w | .1.3.6.1.4.1.63131.1.1.26.8.1.1.4 |
|
User-defined low load bank current
threshold in Amps |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.8.1.1.5 |
|
User-defined near bank overload current warning
threshold in Amps |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.8.1.1.6 |
|
User-defined bank overload current threshold
in Amps |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.8.1.1.7 |
|
rPDU2BankConfigBankPeakCurrentResetmandatory
Setting this OID to reset (2) will cause the existing peak current value
to be replaced by the present load current value. Getting this OID will do nothing and return the noOperation(1) value. |
Enumerationr/w | .1.3.6.1.4.1.63131.1.1.26.8.1.1.8 |
.1.3.6.1.4.1.63131.1.1.26.8.2
·
1 row entry
·
5 columns
Uses the inova variant from
Command help
/opt/observium/mibs/inova.
Walk rPDU2BankPropertiesTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-Inova' -M '/opt/observium/mibs/inova:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-Inova::rPDU2BankPropertiesTable'
A table of Rack PDU bank properties
Properties of the currently queried
Rack PDU bank
Rack PDU bank
Indexes
No indexes recorded
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
rPDU2BankPropertiesIndexmandatory
The index to the Rack PDU bank properties
table entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.8.2.1.1 |
||||||||||||
|
rPDU2BankPropertiesModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.8.2.1.2 |
||||||||||||
|
rPDU2BankPropertiesNumbermandatory
The numeric bank ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.8.2.1.3 |
||||||||||||
|
rPDU2BankPropertiesPhaseLayoutmandatory
This OID describes the outlet phase connections on
the referenced bank as follows: seqPhase1ToNeutral(1) indicates that bank outlets are wired from Phase 1 to Neutral. seqPhase2ToNeutral(2)… |
Rpdu2OutletPhaseLayoutType Type Values:
|
.1.3.6.1.4.1.63131.1.1.26.8.2.1.4 |
||||||||||||
|
rPDU2BankPropertiesBreakerRatingmandatory
If bank circuit breakers are present on the device, this OID will return
the rating of the breaker in Amps. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.8.2.1.5 |
.1.3.6.1.4.1.63131.1.1.26.8.3
·
1 row entry
·
11 columns
Uses the inova variant from
Command help
/opt/observium/mibs/inova.
Walk rPDU2BankStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-Inova' -M '/opt/observium/mibs/inova:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-Inova::rPDU2BankStatusTable'
A table of Rack PDU bank status data
Status data from currently queried Rack PDU
bank
bank
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2BankStatusIndexmandatory
The index to the Rack PDU bank status
table entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.8.3.1.1 |
|
rPDU2BankStatusModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.8.3.1.2 |
|
rPDU2BankStatusNumbermandatory
The numeric bank ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.8.3.1.3 |
|
rPDU2BankStatusLoadStatemandatory
Indicates the present load status of the Rack PDU
bank being queried |
Enumeration | .1.3.6.1.4.1.63131.1.1.26.8.3.1.4 |
|
rPDU2BankStatusCurrentmandatory
Indicates the current draw, in tenths of Amps, of the load
on the Rack PDU bank being queried |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.8.3.1.5 |
|
rPDU2BankStatusPeakCurrentmandatory
The peak current of the Rack PDU bank load in tenths of Amps
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.8.3.1.6 |
|
rPDU2BankStatusPeakCurrentTimestampmandatory
Indicates the date and time the bank peak current occurred
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.63131.1.1.26.8.3.1.7 |
|
rPDU2BankStatusPeakCurrentStartTimemandatory
Indicates the date and time of the last bank peak current reset
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.63131.1.1.26.8.3.1.8 |
|
rPDU2BankStatusVoltagemandatory
Indicates the Voltage, in Volts, of the Rack PDU bank being queried.
Models that do not support this feature will respond to this OID with a value of -1. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.8.3.1.9 |
|
rPDU2BankStatusPowermandatory
Indicates the load power, in hundredths of kilowatts (kW),
consumed on the RackPDU phase being queried. Models that do not support this feature will respond to this OID with a value of -1. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.8.3.1.10 |
|
rPDU2BankStatusEnergymandatory
A user resettable energy meter measuring Rack PDU phase load
energy consumption in tenths of kilowatt-hours. Models that do not support this feature will respond to this OID with a value of -1. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.8.3.1.11 |
.1.3.6.1.4.1.63131.1.1.26.9.2.1
·
1 row entry
·
8 columns
Uses the inova variant from
Command help
/opt/observium/mibs/inova.
Walk rPDU2OutletSwitchedConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-Inova' -M '/opt/observium/mibs/inova:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-Inova::rPDU2OutletSwitchedConfigTable'
A table of Rack PDU switched outlet configuration data
Configuration data from currently queried
Rack PDU switched outlet
Rack PDU switched outlet
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2OutletSwitchedConfigIndexmandatory
The index to the Rack PDU switched outlet
configuration table entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.2.1.1.1 |
|
rPDU2OutletSwitchedConfigModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.2.1.1.2 |
|
rPDU2OutletSwitchedConfigNamemandatory
The user-defined switched outlet ID string
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.63131.1.1.26.9.2.1.1.3 |
|
rPDU2OutletSwitchedConfigNumbermandatory
The numeric switched outlet ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.2.1.1.4 |
|
rPDU2OutletSwitchedConfigPowerOnTimemandatory
The amount of delay, in seconds, between when
power is provided to the Rack PDU and when this switched outlet starts providing power. Range -1...7200 where -1 = Never power on, 0 = immediate power on, and 1-7200 = secon… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.2.1.1.5 |
|
The amount of time, in seconds, this outlet will
delay powering off. Range -1...7200 where -1 = Never power off, 0 = immediate power off, and 1-7200 = seconds to delay. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.2.1.1.6 |
|
After turning power off during a reboot sequence,
the amount of time to wait before turning power to this outlet back on. Range 5-60 seconds delay. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.2.1.1.7 |
|
User-defined external device web link.
Possible use cases could be the IP address of the external device plugged into the outlet or its manufacturer web page for convenient support such as user manuals, specifications… |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.63131.1.1.26.9.2.1.1.8 |
.1.3.6.1.4.1.63131.1.1.26.9.2.2
·
1 row entry
·
6 columns
Uses the inova variant from
Command help
/opt/observium/mibs/inova.
Walk rPDU2OutletSwitchedPropertiesTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-Inova' -M '/opt/observium/mibs/inova:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-Inova::rPDU2OutletSwitchedPropertiesTable'
A table of Rack PDU switched outlet properties
Properties of the currently queried Rack PDU
switched outlet
switched outlet
Indexes
No indexes recorded
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
rPDU2OutletSwitchedPropertiesIndexmandatory
The index to the Rack PDU switched outlet
properties table entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.2.2.1.1 |
||||||||||||
|
rPDU2OutletSwitchedPropertiesModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.2.2.1.2 |
||||||||||||
|
rPDU2OutletSwitchedPropertiesNamemandatory
The user-defined switched outlet ID string
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.63131.1.1.26.9.2.2.1.3 |
||||||||||||
|
rPDU2OutletSwitchedPropertiesNumbermandatory
The numeric switched outlet ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.2.2.1.4 |
||||||||||||
|
This OID describes the phase connections of
the referenced outlet as follows: seqPhase1ToNeutral(1) indicates that the outlet is wired from Phase 1 to Neutral. seqPhase2ToNeutral(2) indicat… |
Rpdu2OutletPhaseLayoutType Type Values:
|
.1.3.6.1.4.1.63131.1.1.26.9.2.2.1.5 |
||||||||||||
|
rPDU2OutletSwitchedPropertiesBankmandatory
The numeric bank ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.2.2.1.6 |
.1.3.6.1.4.1.63131.1.1.26.9.2.3
·
1 row entry
·
7 columns
Uses the inova variant from
Command help
/opt/observium/mibs/inova.
Walk rPDU2OutletSwitchedStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-Inova' -M '/opt/observium/mibs/inova:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-Inova::rPDU2OutletSwitchedStatusTable'
A table of Rack PDU switched outlet status information
Status information for currently queried
Rack PDU switched outlet
Rack PDU switched outlet
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2OutletSwitchedStatusIndexmandatory
The index to the Rack PDU switched outlet
status information table entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.2.3.1.1 |
|
rPDU2OutletSwitchedStatusModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.2.3.1.2 |
|
rPDU2OutletSwitchedStatusNamemandatory
The user-defined switched outlet ID string
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.63131.1.1.26.9.2.3.1.3 |
|
rPDU2OutletSwitchedStatusNumbermandatory
The numeric switched outlet ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.2.3.1.4 |
|
rPDU2OutletSwitchedStatusStatemandatory
Indicates the present switch state of the Rack
PDU switched outlet being queried |
Enumeration | .1.3.6.1.4.1.63131.1.1.26.9.2.3.1.5 |
|
Indicates whether or not the device is
processing a command for this outlet. If the commandPendingUnknown (3) value is returned, all devices powered by the Rack PDU should be shut down. The Rack PDU's po… |
Enumeration | .1.3.6.1.4.1.63131.1.1.26.9.2.3.1.6 |
|
Each RPDU outlet can have its own external web URL link.
This can be configured in the rPDU2OutletSwitchedConfigExternalLink OID. When this link is clicked in the web interface, the linked URL will open in the web b… |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.63131.1.1.26.9.2.3.1.7 |
.1.3.6.1.4.1.63131.1.1.26.9.2.4
·
1 row entry
·
5 columns
Uses the inova variant from
Command help
/opt/observium/mibs/inova.
Walk rPDU2OutletSwitchedControlTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-Inova' -M '/opt/observium/mibs/inova:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-Inova::rPDU2OutletSwitchedControlTable'
A table of Rack PDU switched outlet control data
Control data for currently queried Rack
PDU switched outlet
PDU switched outlet
Indexes
| Column | Syntax | OID |
|---|---|---|
|
rPDU2OutletSwitchedControlIndexmandatory
The index to the Rack PDU switched outlet
control data table entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.2.4.1.1 |
|
rPDU2OutletSwitchedControlModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.2.4.1.2 |
|
rPDU2OutletSwitchedControlNamemandatory
The user-defined switched outlet ID string
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.63131.1.1.26.9.2.4.1.3 |
|
rPDU2OutletSwitchedControlNumbermandatory
The numeric switched outlet ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.2.4.1.4 |
|
rPDU2OutletSwitchedControlCommandmandatory
Getting this variable will return the outlet state. If
the outlet is on, the immediateOn (1) value will be returned. If the outlet is off, the immediateOff (2) value will be returned. If the state of the outlet cannot b… |
Enumerationr/w | .1.3.6.1.4.1.63131.1.1.26.9.2.4.1.5 |
.1.3.6.1.4.1.63131.1.1.26.9.4.1
·
1 row entry
·
8 columns
Uses the inova variant from
Command help
/opt/observium/mibs/inova.
Walk rPDU2OutletMeteredConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-Inova' -M '/opt/observium/mibs/inova:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-Inova::rPDU2OutletMeteredConfigTable'
A table of Rack PDU metered outlet configuration data
Configuration data from currently queried
Rack PDU metered outlet
Rack PDU metered outlet
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2OutletMeteredConfigIndexmandatory
The index to the Rack PDU metered outlet
configuration table entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.1.1.1 |
|
rPDU2OutletMeteredConfigModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.1.1.2 |
|
rPDU2OutletMeteredConfigNamemandatory
The user-defined metered outlet ID string
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.63131.1.1.26.9.4.1.1.3 |
|
rPDU2OutletMeteredConfigNumbermandatory
The numeric switched outlet ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.1.1.4 |
|
User-defined low load outlet current threshold in in tenths of Amps
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.1.1.5 |
|
User-defined near outlet overload warning threshold
in in tenths of Amps |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.1.1.6 |
|
User-defined outlet overload current threshold in in tenths of Amps
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.1.1.7 |
|
rPDU2OutletMeteredConfigExternalLinkmandatory
User-defined external device web link.
Possible use cases could be the IP address of the external device plugged into the outlet or its manufacturer web page for convenient support such as user manuals, specifications… |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.63131.1.1.26.9.4.1.1.8 |
.1.3.6.1.4.1.63131.1.1.26.9.4.2
·
1 row entry
·
7 columns
Uses the inova variant from
Command help
/opt/observium/mibs/inova.
Walk rPDU2OutletMeteredPropertiesTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-Inova' -M '/opt/observium/mibs/inova:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-Inova::rPDU2OutletMeteredPropertiesTable'
A table of Rack PDU metered outlet properties
Properties of currently queried Rack PDU
metered outlet
metered outlet
Indexes
No indexes recorded
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
rPDU2OutletMeteredPropertiesIndexmandatory
The index to the Rack PDU metered properties table
entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.2.1.1 |
||||||||||||
|
rPDU2OutletMeteredPropertiesModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.2.1.2 |
||||||||||||
|
rPDU2OutletMeteredPropertiesNamemandatory
The user-defined metered outlet ID string
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.63131.1.1.26.9.4.2.1.3 |
||||||||||||
|
rPDU2OutletMeteredPropertiesNumbermandatory
The numeric metered outlet ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.2.1.4 |
||||||||||||
|
rPDU2OutletMeteredPropertiesLayoutmandatory
This OID describes the phase connections of
the referenced outlet as follows: seqPhase1ToNeutral(1) indicates that the outlet is wired from Phase 1 to Neutral. seqPhase2ToNeutral(2) indicat… |
Rpdu2OutletPhaseLayoutType Type Values:
|
.1.3.6.1.4.1.63131.1.1.26.9.4.2.1.5 |
||||||||||||
|
Maximum power rating of Rack PDU metered outlet
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.2.1.6 |
||||||||||||
|
rPDU2OutletMeteredPropertiesBankmandatory
This outlet's numeric bank ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.2.1.7 |
.1.3.6.1.4.1.63131.1.1.26.9.4.3
·
1 row entry
·
16 columns
Uses the inova variant from
Command help
/opt/observium/mibs/inova.
Walk rPDU2OutletMeteredStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-Inova' -M '/opt/observium/mibs/inova:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-Inova::rPDU2OutletMeteredStatusTable'
A table of Rack PDU metered outlet status data
Status data from currently queried Rack PDU
metered outlet
metered outlet
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2OutletMeteredStatusIndexmandatory
The index to the Rack PDU metered status table
entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.1 |
|
rPDU2OutletMeteredStatusModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.2 |
|
rPDU2OutletMeteredStatusNamemandatory
The user-defined metered outlet ID string
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.63131.1.1.26.9.4.3.1.3 |
|
rPDU2OutletMeteredStatusNumbermandatory
The numeric metered outlet ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.4 |
|
rPDU2OutletMeteredStatusStatemandatory
Indicates the present load status of the Rack
PDU metered outlet being queried |
Enumeration | .1.3.6.1.4.1.63131.1.1.26.9.4.3.1.5 |
|
rPDU2OutletMeteredStatusCurrentmandatory
Indicates the current draw, in tenths
of Amps, of the load on the Rack PDU outlet being queried |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.6 |
|
rPDU2OutletMeteredStatusPowermandatory
Indicates the power draw of the load
on the Rack PDU outlet being queried |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.7 |
|
rPDU2OutletMeteredStatusPeakPowermandatory
Indicates the peak power load draw
on the Rack PDU outlet being queried |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.8 |
|
Indicates the date and time that this metered
outlet's peak power consumption occurred |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.63131.1.1.26.9.4.3.1.9 |
|
Indicates the start date and time that this metered
outlet began recording peak power observations |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.63131.1.1.26.9.4.3.1.10 |
|
rPDU2OutletMeteredStatusEnergymandatory
A user resettable energy meter measuring Rack PDU load
energy consumption in tenths of kilowatt-hours |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.11 |
|
Indicates receptacle type for the outlet.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.63131.1.1.26.9.4.3.1.12 |
|
rPDU2OutletMeteredStatusExternalLinkmandatory
Each RPDU outlet can have its own external web URL link.
This can be configured in the rPDU2OutletMeteredConfigExternalLink OID. When this link is clicked in the web interface, the linked URL will open in the web br… |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.63131.1.1.26.9.4.3.1.13 |
|
rPDU2OutletMeteredStatusPowerFactormandatory
The power factor of the Rack PDU outlet in hundredths. Models that do not support this feature
will respond to this OID with a value of -1. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.14 |
|
The apparent power consumption of the Rack PDU outlet load in hundredths of kiloVoltAmps (kVA).
Models that do not support this feature will respond to this OID with a value of -1. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.15 |
|
rPDU2OutletMeteredStatusVoltagemandatory
Indicates the Voltage, in Volts, of the Rack PDU outlet being queried.
Models that do not support this feature will respond to this OID with a value of -1. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.9.4.3.1.16 |
.1.3.6.1.4.1.63131.1.1.26.10.2.1
·
1 row entry
·
16 columns
Uses the inova variant from
Command help
/opt/observium/mibs/inova.
Walk rPDU2SensorTempHumidityConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-Inova' -M '/opt/observium/mibs/inova:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-Inova::rPDU2SensorTempHumidityConfigTable'
A table of temperature-humidity sensor configuration data
Configuration data from temperature-humidity sensor
being queried
being queried
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2SensorTempHumidityConfigIndexmandatory
The index to the temperature-humidity sensor
configuration data table entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.1 |
|
rPDU2SensorTempHumidityConfigModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.2 |
|
rPDU2SensorTempHumidityConfigNamemandatory
The user-defined temperature-humidity
sensor ID string |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.63131.1.1.26.10.2.1.1.3 |
|
rPDU2SensorTempHumidityConfigNumbermandatory
The temperature-humidity sensor numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.4 |
|
Setting this OID enables or disables generation
of sensor temperature alarm. Getting this OID returns the current value of the temperature alarm enable. |
Enumerationr/w | .1.3.6.1.4.1.63131.1.1.26.10.2.1.1.5 |
|
Setting this OID enables or disables generation
of sensor humidity alarm. Getting this OID returns the current value of the humidity alarm enable. |
Enumerationr/w | .1.3.6.1.4.1.63131.1.1.26.10.2.1.1.6 |
|
Sensor maximum temperature alarm threshold in
Fahrenheit. Attempting to set this OID to a value less than or equal to that of rPDU2SensorTempHumidityConfigTempHighThreshF will result in an error. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.7 |
|
Sensor high temperature warning alarm threshold
in Fahrenheit. Attempting to set this OID to a value greater than or equal to that of rPDU2SensorTempHumidityConfigTempMaxThreshF will result in an error. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.8 |
|
Sensor temperature hysteresis setting in Fahrenheit
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.9 |
|
Sensor maximum temperature alarm threshold
in Celsius. Attempting to set this OID to a value less than or equal to that of rPDU2SensorTempHumidityConfigTempHighThreshC will result in an error. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.10 |
|
Sensor high temperature warning alarm threshold
in Celsius. Attempting to set this OID to a value greater than or equal to that of rPDU2SensorTempHumidityConfigTempMaxThreshC will result in an error. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.11 |
|
Sensor temperature hysteresis setting in Celsius
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.12 |
|
Sensor low humidity warning alarm threshold in percent
relative humidity. Attempting to set this OID to a value less than or equal to that of rPDU2SensorTempHumidityConfigHumidityMinThresh will result in an error. Must … |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.13 |
|
Sensor minimum humidity alarm threshold in percent
relative humidity. Attempting to set this OID to a value greater than or equal to that of rPDU2SensorTempHumidityConfigHumidityLowThresh will result in an error. Must b… |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.14 |
|
Sensor humidity hysteresis setting in percent relative
humidity |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.1.1.15 |
|
Setting this OID to reset (2) will cause the existing peak temperature
to be replaced by the present temperature reading. Getting this OID will do nothing and return the noOperation(1) value. |
Enumerationr/w | .1.3.6.1.4.1.63131.1.1.26.10.2.1.1.16 |
.1.3.6.1.4.1.63131.1.1.26.10.2.2
·
1 row entry
·
15 columns
Uses the inova variant from
Command help
/opt/observium/mibs/inova.
Walk rPDU2SensorTempHumidityStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-Inova' -M '/opt/observium/mibs/inova:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-Inova::rPDU2SensorTempHumidityStatusTable'
A table of temperature-humidity sensor status data
Status information from temperature-humidity sensor
being queried
being queried
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2SensorTempHumidityStatusIndexmandatory
The index to the temperature-humidity
status data table entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.2.1.1 |
|
rPDU2SensorTempHumidityStatusModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.2.1.2 |
|
rPDU2SensorTempHumidityStatusNamemandatory
The user-defined temperature-humidity
sensor ID string |
RFC1213-MIBDisplayString | .1.3.6.1.4.1.63131.1.1.26.10.2.2.1.3 |
|
rPDU2SensorTempHumidityStatusNumbermandatory
The temperature-humidity sensor numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.2.1.4 |
|
rPDU2SensorTempHumidityStatusTypemandatory
The type of the sensor
|
Enumeration | .1.3.6.1.4.1.63131.1.1.26.10.2.2.1.5 |
|
The communications status of the sensor
|
Enumeration | .1.3.6.1.4.1.63131.1.1.26.10.2.2.1.6 |
|
rPDU2SensorTempHumidityStatusTempFmandatory
Sensor temperature reading in tenths of degrees Fahrenheit
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.2.1.7 |
|
rPDU2SensorTempHumidityStatusTempCmandatory
Sensor temperature reading in tenths of degrees Celsius
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.2.1.8 |
|
This OID reports the current state of the temperature probe.
A notPresent (1) response indicates that no probe is attached. A belowMin (2) response indicates that the probe is present and its measured tem… |
Enumeration | .1.3.6.1.4.1.63131.1.1.26.10.2.2.1.9 |
|
Sensor humidity reading in percent relative humidity
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.2.1.10 |
|
This OID reports the current state of the humidity probe.
A notPresent (1) response indicates that no probe is attached. A belowMin (2) response indicates that the probe is present and its measured humidi… |
Enumeration | .1.3.6.1.4.1.63131.1.1.26.10.2.2.1.11 |
|
Sensor peak temperature in tenths of degrees Fahrenheit
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.2.1.12 |
|
Sensor peak temperature in tenths of degrees Celsius
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.2.2.1.13 |
|
Indicates the date and time that the peak temperature occurred
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.63131.1.1.26.10.2.2.1.14 |
|
Indicates the date and time of the last temperature peak reset
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.63131.1.1.26.10.2.2.1.15 |
.1.3.6.1.4.1.63131.1.1.26.10.4.1
·
1 row entry
·
6 columns
Uses the inova variant from
Command help
/opt/observium/mibs/inova.
Walk rPDU2SensorDiscreteConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-Inova' -M '/opt/observium/mibs/inova:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-Inova::rPDU2SensorDiscreteConfigTable'
A table of discrete sensor configuration data
Configuration data from discreste sensor
being queried
being queried
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2SensorDiscreteConfigIndexmandatory
The index to the discrete sensor configuration
data table entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.4.1.1.1 |
|
rPDU2SensorDiscreteConfigModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.4.1.1.2 |
|
rPDU2SensorDiscreteConfigNamemandatory
The user-defined discrete sensor ID string
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.63131.1.1.26.10.4.1.1.3 |
|
rPDU2SensorDiscreteConfigNumbermandatory
The discrete sensor numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.4.1.1.4 |
|
rPDU2SensorDiscreteConfigNormalStatemandatory
Indicates the normal state of the discrete input
contact |
Enumerationr/w | .1.3.6.1.4.1.63131.1.1.26.10.4.1.1.5 |
|
Indicates the severity of alarm triggered by
abnormal discrete input contact state |
Enumerationr/w | .1.3.6.1.4.1.63131.1.1.26.10.4.1.1.6 |
.1.3.6.1.4.1.63131.1.1.26.10.4.2
·
1 row entry
·
8 columns
Uses the inova variant from
Command help
/opt/observium/mibs/inova.
Walk rPDU2SensorDiscreteStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-Inova' -M '/opt/observium/mibs/inova:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-Inova::rPDU2SensorDiscreteStatusTable'
A table of discrete sensor status data
Status information from discrete sensor
being queried
being queried
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2SensorDiscreteStatusIndexmandatory
The index to the discrete sensor status data
table entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.4.2.1.1 |
|
rPDU2SensorDiscreteStatusModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.4.2.1.2 |
|
rPDU2SensorDiscreteStatusNamemandatory
The user-defined discrete sensor ID string
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.63131.1.1.26.10.4.2.1.3 |
|
rPDU2SensorDiscreteStatusNumbermandatory
The discrete sensor numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.10.4.2.1.4 |
|
rPDU2SensorDiscreteStatusTypemandatory
The type of discrete sensor currently being queried
|
Enumeration | .1.3.6.1.4.1.63131.1.1.26.10.4.2.1.5 |
|
rPDU2SensorDiscreteStatusCommStatusmandatory
The communications status of the sensor
|
Enumeration | .1.3.6.1.4.1.63131.1.1.26.10.4.2.1.6 |
|
The current open/close state of the discrete
sensor |
Enumeration | .1.3.6.1.4.1.63131.1.1.26.10.4.2.1.7 |
|
rPDU2SensorDiscreteStatusAlarmStatemandatory
Indicates alarm status of discrete sensor input
|
Enumeration | .1.3.6.1.4.1.63131.1.1.26.10.4.2.1.8 |
.1.3.6.1.4.1.63131.1.1.26.13.1
·
1 row entry
·
5 columns
Uses the inova variant from
Command help
/opt/observium/mibs/inova.
Walk rPDU2PhaseToPhaseStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-Inova' -M '/opt/observium/mibs/inova:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-Inova::rPDU2PhaseToPhaseStatusTable'
A table of Rack PDU phase to phase status data. This table is only applicable to SKUs that have phase to phase outputs.
Status data from currently queried Rack PDU
phase to phase outputs
phase to phase outputs
| Column | Syntax | OID |
|---|---|---|
|
rPDU2PhaseToPhaseStatusIndexmandatory
The index to the Rack PDU phase to phase status table
entry |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.13.1.1.1 |
|
rPDU2PhaseToPhaseStatusModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.13.1.1.2 |
|
rPDU2PhaseToPhaseStatusVoltage1to2mandatory
Indicates the Voltage, in Volts, of the Rack
PDU phase 1 to phase 2 output being queried |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.13.1.1.3 |
|
rPDU2PhaseToPhaseStatusVoltage2to3mandatory
Indicates the Voltage, in Volts, of the Rack
PDU phase 2 to phase 3 output being queried |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.13.1.1.4 |
|
rPDU2PhaseToPhaseStatusVoltage3to1mandatory
Indicates the Voltage, in Volts, of the Rack
PDU phase 3 to phase 2 output being queried |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.13.1.1.5 |
.1.3.6.1.4.1.63131.1.1.26.15.1
·
1 row entry
·
8 columns
Uses the inova variant from
Command help
/opt/observium/mibs/inova.
Walk rPDU2RCMTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-Inova' -M '/opt/observium/mibs/inova:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-Inova::rPDU2RCMTable'
A table of Rack PDU RCM.
RCM data from currently queried Rack PDU
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
rPDU2RCMIndexmandatory
The index to the Rack PDU RCM table entry
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.15.1.1.1 |
|
rPDU2RCMModulemandatory
The user-defined Rack PDU numeric ID
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.15.1.1.2 |
|
rPDU2RCMCurrentmandatory
RCM RMS current. (mA)
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.15.1.1.3 |
|
rPDU2RCMAlarmStatusmandatory
RCM alarm status.
Setting the selected variable to 1, will clear the over alarm. |
Enumerationr/w | .1.3.6.1.4.1.63131.1.1.26.15.1.1.4 |
|
rPDU2RCMSelfCheckCommandmandatory
Getting this variable will return the RCM self checking status,
1: featureNotAvailable(-1) 2: success(1) 3: failed(2) 4: pending(3). Setting any of the selected pdu's rcm's variable to 1, will immediately start RCM Sel… |
Enumerationr/w | .1.3.6.1.4.1.63131.1.1.26.15.1.1.5 |
|
rPDU2RCMWarningThresholdmandatory
Over Warning threshold of RCM current. (mA),
threshold can be set in the range of 15-300mA, and must be lower or equal than Alarm threshold. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.15.1.1.6 |
|
rPDU2RCMAlarmThresholdmandatory
Over Alarm threshold of RCM current. (mA),
threshold can be set in the range of 15~300 mA, and must be higher or equal than Warning threshold. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.15.1.1.7 |
|
rPDU2RCMSelfCheckPeriodmandatory
RCM Self-Checking Period. (day)
period can be set in the range of 1~365 days, the rcm period on a single pdu is the same, setting one of the selected pdu's rcm's period, will change all rcm's period of this pdu. |
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.1.26.15.1.1.8 |
.1.3.6.1.4.1.63131.1.2.1.2.2
·
1 row entry
·
4 columns
Uses the inova variant from
Command help
/opt/observium/mibs/inova.
Walk powerNetSoftwareTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-Inova' -M '/opt/observium/mibs/inova:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-Inova::powerNetSoftwareTable'
A list of the software monitoring the UPS.
An entry containing information on a software module.
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
moduleNumbermandatory
The index into the Software Entry Table
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.2.1.2.2.1.1 |
|
moduleNamemandatory
The name of the software module.
|
OctetString | .1.3.6.1.4.1.63131.1.2.1.2.2.1.2 |
|
moduleVersionmandatory
The version of the software module.
|
OctetString | .1.3.6.1.4.1.63131.1.2.1.2.2.1.3 |
|
moduleDatemandatory
The date of the software module represented as mm-dd-yy.
|
OctetString | .1.3.6.1.4.1.63131.1.2.1.2.2.1.4 |
.1.3.6.1.4.1.63131.1.2.3.3.4
·
1 row entry
·
3 columns
Uses the inova variant from
Command help
/opt/observium/mibs/inova.
Walk pcnsNmcTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-Inova' -M '/opt/observium/mibs/inova:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-Inova::pcnsNmcTable'
The Network Management Cards in the UPS's which PCNS is monitoring to provide safe shutdown.
Details of the NMC.
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
pcnsNmcIndexmandatory
Index of the NMC within PCNS setup.
|
RFC1155-SMIGauge Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.63131.1.2.3.3.4.1.1 |
|
pcnsNmcAddrmandatory
The IP address of the NMC.
|
RFC1155-SMIIpAddress Type Constraints: range: 4 |
.1.3.6.1.4.1.63131.1.2.3.3.4.1.2 |
|
pcnsNmcOutletmandatory
The Outlet Group which PCNS is enrolled with on the NMC.
|
RFC1155-SMIGauge Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.63131.1.2.3.3.4.1.3 |
.1.3.6.1.4.1.63131.1.2.3.5.9
·
1 row entry
·
11 columns
Uses the inova variant from
Command help
/opt/observium/mibs/inova.
Walk pcnsAdvancedShutdownTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-Inova' -M '/opt/observium/mibs/inova:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-Inova::pcnsAdvancedShutdownTable'
The Network Management Cards in the UPS's which PCNS is monitoring to provide safe shutdown.
Details of the NMC.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
pcnsAdvancedGroupNomandatory
Index of the Advanced Shutdown Group.
|
RFC1155-SMIGauge Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.63131.1.2.3.5.9.1.1 |
|
pcnsAdvancedGroupNamemandatory
Name of the Advanced Shutdown Group.
|
OctetStringr/w | .1.3.6.1.4.1.63131.1.2.3.5.9.1.2 |
|
pcnsAdvancedGroupNMCmandatory
List of NMCs in the Advanced Shutdown Group.
|
RFC1213-MIBDisplayString | .1.3.6.1.4.1.63131.1.2.3.5.9.1.3 |
|
Number of UPS's required to power load.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.2.3.5.9.1.4 |
|
Run a shutdown command file before performing graceful shutdown.
|
Enumerationr/w | .1.3.6.1.4.1.63131.1.2.3.5.9.1.5 |
|
pcnsAdvancedShutdownCommandFilemandatory
Full name of the shutdown command file to run before graceful shutdown.
|
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.63131.1.2.3.5.9.1.6 |
|
How long in seconds shutdown command file takes to run.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.1.2.3.5.9.1.7 |
|
pcnsAdvancedShutdownPowerchuteServermandatory
Shut down PowerChute Server.
|
Enumerationr/w | .1.3.6.1.4.1.63131.1.2.3.5.9.1.8 |
|
pcnsAdvancedShutdownOnLostRedundancymandatory
Shut down if Redundancy lost.
|
Enumerationr/w | .1.3.6.1.4.1.63131.1.2.3.5.9.1.9 |
|
pcnsAdvancedTurnOffUpsmandatory
Turn off the UPS when performing a graceful shutdown.
|
Enumerationr/w | .1.3.6.1.4.1.63131.1.2.3.5.9.1.10 |
|
pcnsAdvancedTurnOffSOGmandatory
Turn off the Outlet Group on the UPS when performing a graceful shutdown.
|
Enumerationr/w | .1.3.6.1.4.1.63131.1.2.3.5.9.1.11 |
.1.3.6.1.4.1.63131.2.1.2
·
1 row entry
·
6 columns
Uses the inova variant from
Command help
/opt/observium/mibs/inova.
Walk mconfigTrapReceiverTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PowerNet-Inova' -M '/opt/observium/mibs/inova:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PowerNet-Inova::mconfigTrapReceiverTable'
A list of managers to send traps to. The number of entries is given by the value of mconfigNumTrapReceivers.
The managers to send traps to.
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
|
trapIndexmandatory
The index to a trap receiver entry.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.63131.2.1.2.1.1 |
|
receiverAddrmandatory
The IP address of the manager to send a trap to.
|
RFC1155-SMIIpAddressr/w Type Constraints: range: 4 |
.1.3.6.1.4.1.63131.2.1.2.1.2 |
|
communityStringmandatory
The community name to use in the trap when
sent to the manager. |
RFC1213-MIBDisplayStringr/w | .1.3.6.1.4.1.63131.2.1.2.1.3 |
|
severityobsolete
The severity threshold of traps to send to the manager.
traps are labeled in severity as informational(1), warning(2), severe(3). Only traps of equal or greater severity than this value are sent to the manager. |
Enumeration | .1.3.6.1.4.1.63131.2.1.2.1.4 |
|
acceptThisReceivermandatory
The value of yes(1) indicates that trap generation for this manager is enabled.
The value of no(2) indicates that trap generation for this manager is disabled |
Enumerationr/w | .1.3.6.1.4.1.63131.2.1.2.1.5 |
|
receiveTrapTypeobsolete
Type of trap.
|
Enumeration | .1.3.6.1.4.1.63131.2.1.2.1.6 |