PoE-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
4
Rows
4
Columns
26
.1.3.6.1.4.1.171.12.24.1.11 · 1 row entry · 6 columns
Uses the d-link variant from /opt/observium/mibs/d-link.
Command help
Walk swPoESystemStackingCtrlTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PoE-MIB' -M '/opt/observium/mibs/d-link:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PoE-MIB::swPoESystemStackingCtrlTable'
A table that is used to configure PoE system information based on Unit ID.
The Unit ID is used for stacking.
swPoESystemStackingCtrlEntry row .1.3.6.1.4.1.171.12.24.1.11.1
A list of PoE system information based on Unit ID.
Column Syntax OID
This object indicates the device's Unit ID.
A unit ID of zero denotes a stand-alone device.
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.171.12.24.1.11.1.1
The power budget (in watts) of the PoE sytem.
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.171.12.24.1.11.1.2
The power management disconnection method. When the total consumed power
exceeds the power budget, the PoE controller initiates port disconnection
to prevent overloading the power supply. The controller uses one of the
Enumerationr/w
Enumerated Values:
1denyNextPort
2denyLowPriorityPort
.1.3.6.1.4.1.171.12.24.1.11.1.3
This mode can be either power_limit mode or auto mode.
power_limit: If power supplied to the port exceeds the power limit
specified for it, this port will be shut down.
auto: The system will automatically determine the …
Enumerationr/w
Enumerated Values:
1power-limit
2auto
.1.3.6.1.4.1.171.12.24.1.11.1.4
Specifies the system mode to be POE or NORMAL.
Enumerationr/w
Enumerated Values:
1normal
2poe
.1.3.6.1.4.1.171.12.24.1.11.1.5
The legacy PD detection state. Enables or disables legacy PD detection on PoE unit.
Enumerationr/w
Enumerated Values:
1enabled
2disabled
.1.3.6.1.4.1.171.12.24.1.11.1.6
.1.3.6.1.4.1.171.12.24.2.1 · 1 row entry · 7 columns
Uses the d-link variant from /opt/observium/mibs/d-link.
Command help
Walk swPoESystemInfoTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PoE-MIB' -M '/opt/observium/mibs/d-link:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PoE-MIB::swPoESystemInfoTable'
A table that contains PoE system information based on Unit ID.
The Unit ID is used for stacking.
swPoESystemInfoEntry row .1.3.6.1.4.1.171.12.24.2.1.1
A list of PoE system information based on Unit ID.
Column Syntax OID
This object indicates the device's Unit ID.
A unit ID of zero denotes a stand-alone device.
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.171.12.24.2.1.1.1
The actual momentary power consumption (in watts) in the PoE system.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.171.12.24.2.1.1.2
The actual momentary remaining power (in watts) in the PoE system.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.171.12.24.2.1.1.3
The power budget (in watts) of the PoE sytem.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.171.12.24.2.1.1.4
The power management disconnection method. When the total consumed power
exceeds the power budget, the PoE controller initiates port disconnection
to prevent overloading the power supply. The controller uses one of the
Enumeration
Enumerated Values:
1denyNextPort
2denyLowPriorityPort
.1.3.6.1.4.1.171.12.24.2.1.1.5
This mode can be either power_limit mode or auto mode.
power_limit: If power supplied to the port exceeds the power limit
specified for it, this port will be shut down.
auto: The system will automatically determine the…
Enumeration
Enumerated Values:
1power-limit
2auto
.1.3.6.1.4.1.171.12.24.2.1.1.6
The current status of legacy PD detection.
Enumeration
Enumerated Values:
1enabled
2disabled
.1.3.6.1.4.1.171.12.24.2.1.1.7
.1.3.6.1.4.1.171.12.24.3.1 · 1 row entry · 6 columns
Uses the d-link variant from /opt/observium/mibs/d-link.
Command help
Walk swPoEPortCtrlTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PoE-MIB' -M '/opt/observium/mibs/d-link:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PoE-MIB::swPoEPortCtrlTable'
A table that contains PoE configuration about every port in this stack.
If a device has N ports, then the 1 -- N ports describe the port number of BoxId 1 device;
N+1 -- 2N describe the port number of BoxId 2 device;
2N+1 -- 3N describe the port number of BoxId 2 device;
......
swPoEPortCtrlEntry row .1.3.6.1.4.1.171.12.24.3.1.1
A list of PoE configurations for each port of the device in this stack.
Column Syntax OID
This object indicates the devices' port number in this stack.
If a device has N ports, then the 1 -- N ports describe the port number of BoxId 1 device;
N+1 -- 2N describe the port number of BoxId 2 device;
2N+1 -- 3N d…
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.171.12.24.3.1.1.1
The PoE port state. Enables or disables the PoE function on the specific port.
The default setting is enable.
Enumerationr/w
Enumerated Values:
1other
2enable
3disable
.1.3.6.1.4.1.171.12.24.3.1.1.2
The PoE port priority. Port priority affects power-up order (after a
rest, the ports are powered up according to their priority) and shutdown
order (when exceeding the power budget, the ports are shut down according
to …
Enumerationr/w
Enumerated Values:
1critical
2high
3low
.1.3.6.1.4.1.171.12.24.3.1.1.3
There are 4 pre-defined values for users' convenience to set the upper
power limit for class 0, class 1, class 2, and class 3.
class_0: 15400mW (The maximum power provided by PSE (switch) is 12.95 W + power loss on cabl…
Enumerationr/w
Enumerated Values:
1class0
2class1
3class2
4class3
5user-defined
.1.3.6.1.4.1.171.12.24.3.1.1.4
User defined per-port power limit (in milliwatts). If a port exceeds 10% of its power
limit, the PoE system will shut down that port. The default setting is 15400 mW.
Note: This object is valid only while the swPoEPortC…
Integer32r/w
Constraints:
range: 1000-35000
.1.3.6.1.4.1.171.12.24.3.1.1.5
Specifies the time_range that applies to the port of the POE.If time range is configured,
power can only be supplied during the period specified by the time range.
OctetStringr/w
Constraints:
range: 0-32
.1.3.6.1.4.1.171.12.24.3.1.1.6
.1.3.6.1.4.1.171.12.24.4.1 · 1 row entry · 7 columns
Uses the d-link variant from /opt/observium/mibs/d-link.
Command help
Walk swPoEPortInfoTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PoE-MIB' -M '/opt/observium/mibs/d-link:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PoE-MIB::swPoEPortInfoTable'
A table that contains PoE information about every port in this stack.
If a device has N ports, then the 1 -- N ports describe the port number of BoxID 1 device;
N+1 -- 2N describe the port number of BoxID 2 device;
2N+1 -- 3N describe the port number of BoxID 2 device;
......
swPoEPortInfoEntry row .1.3.6.1.4.1.171.12.24.4.1.1
A list of PoE information for each port of the device in this stack.
Column Syntax OID
This object indicates the devices' port number in this stack.
If a device has N ports, then the 1 -- N ports describe the port number of BoxId 1 device;
N+1 -- 2N describe the port number of BoxID 2 device;
2N+1 -- 3N d…
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.171.12.24.4.1.1.1
The power class of the PD according to 802.3af definitions:
class 0: PD power consumption is within 0.44-12.95 watts,
class 1: PD power consumption is within 0.44-3.84 watts,
class 2: PD power consumption is within 3.84…
Integer32
Constraints:
range: 0-4
.1.3.6.1.4.1.171.12.24.4.1.1.2
The port power consumption (in milliwatts).
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.171.12.24.4.1.1.3
The port input line voltage (in decivolts).
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.171.12.24.4.1.1.4
The port current (calculated in milliamps).
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.171.12.24.4.1.1.5
The string describes the PoE port current status.
OctetString
Constraints:
range: 0-76
.1.3.6.1.4.1.171.12.24.4.1.1.6
The LED display for PoE port status.
on (1): power is provided to the port on which a 802.3af-compliant
or legacy PD is connected,
off(2): no power is provided to the port where there aren't any errors,
error(…
Enumeration
Enumerated Values:
1on
2off
3error
.1.3.6.1.4.1.171.12.24.4.1.1.7