PANASAS-HW-MIB-V1 Table View
Table-centric layout grouping table, row, and column objects.
Tables
18
Rows
18
Columns
109
panHwShelfTable
table.1.3.6.1.4.1.10159.1.2.1.1
·
1 row entry
·
5 columns
Uses the panasas variant from
Command help
/opt/observium/mibs/panasas.
Walk panHwShelfTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PANASAS-HW-MIB-V1' -M '/opt/observium/mibs/panasas:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PANASAS-HW-MIB-V1::panHwShelfTable'
The ShelfTable. This table is extended by several tables that describe shelf resources.
Shelf Hardware Information
Indexes
| Column | Syntax | OID |
|---|---|---|
| panHwShelfSNFactory assigned unique Serial Number of a shelf and an index into panHwShelfTable. | PANASAS-TC-MIBPanSerialNumber Type Constraints: range: 8..32 | .1.3.6.1.4.1.10159.1.2.1.1.1.1 |
panHwShelfModelNumberobsolete Model number of shelf. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.1.1.1.2 |
panHwShelfModelNameobsolete Shelf's model name. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.1.1.1.3 |
| panHwShelfHwRevShelf's hardware revision. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.1.1.1.4 |
| panHwShelfNameAdministrator assigned name for a shelf. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.1.1.1.5 |
panHwShelfPSTable
table.1.3.6.1.4.1.10159.1.2.1.2
·
1 row entry
·
8 columns
Uses the panasas variant from
Command help
/opt/observium/mibs/panasas.
Walk panHwShelfPSTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PANASAS-HW-MIB-V1' -M '/opt/observium/mibs/panasas:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PANASAS-HW-MIB-V1::panHwShelfPSTable'
Extends panHwShelfTable. Lists the power supplies in a shelf. NOTE: several attributes have been obsoleted.
An entry in panHwShelfPSTable.
Indexes
| Column | Syntax | OID |
|---|---|---|
| panHwShelfPSIndexIndex into panHwShelfPSTable. | Integer32 Constraints: range: 1-5 | .1.3.6.1.4.1.10159.1.2.1.2.1.1 |
| panHwShelfPSSerialPower supply serial number. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.1.2.1.2 |
panHwShelfPSModelNumberobsolete Power supply model number. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.1.2.1.3 |
panHwShelfPSModelNameobsolete Power supply model name. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.1.2.1.4 |
panHwShelfPSVoltageACobsolete Status of AC Voltage to power supply. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.1.2.1.5 |
panHwShelfPSVoltage12dot0obsolete Status of 12.0 Voltage from power supply. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.1.2.1.6 |
panHwShelfPSVoltage5dot0obsolete Status of 5.0 Voltage from power supply. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.1.2.1.7 |
panHwShelfPSVoltage3dot3obsolete Status of 3.3 Voltage from power supply. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.1.2.1.8 |
panHwShelfBatteryTable
table.1.3.6.1.4.1.10159.1.2.1.3
·
1 row entry
·
6 columns
Uses the panasas variant from
Command help
/opt/observium/mibs/panasas.
Walk panHwShelfBatteryTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PANASAS-HW-MIB-V1' -M '/opt/observium/mibs/panasas:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PANASAS-HW-MIB-V1::panHwShelfBatteryTable'
Extends panHwShelfTable. Lists the batteries in a shelf.
An entry in panHwShelfBatteryTable.
Indexes
| Column | Syntax | OID |
|---|---|---|
| panHwShelfBatteryIndexAn index into panHwShelfBatteryTable. | Integer32 Constraints: range: 1-5 | .1.3.6.1.4.1.10159.1.2.1.3.1.1 |
| panHwShelfBatterySerialBattery serial number. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.1.3.1.2 |
panHwShelfBatteryModelNumberobsolete Battery model number. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.1.3.1.3 |
| panHwShelfBatteryModelNameBattery model name. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.1.3.1.4 |
panHwShelfBatteryVoltageobsolete Status of battery voltage. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.1.3.1.5 |
panHwShelfBatteryStateobsolete Current state of battery. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.1.3.1.6 |
panHwShelfNetCardTable
table.1.3.6.1.4.1.10159.1.2.1.4
·
1 row entry
·
5 columns
Uses the panasas variant from
Command help
/opt/observium/mibs/panasas.
Walk panHwShelfNetCardTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PANASAS-HW-MIB-V1' -M '/opt/observium/mibs/panasas:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PANASAS-HW-MIB-V1::panHwShelfNetCardTable'
Extends panHwShelfTable. Lists the NETCARD (aka Network Switch cards) in a shelf.
Entry in panHwShelfNetCardTable.
Indexes
| Column | Syntax | OID |
|---|---|---|
| panHwShelfNetCardIndexAn index into panHwShelfNetCardTable. | Integer32 Constraints: range: 1-5 | .1.3.6.1.4.1.10159.1.2.1.4.1.1 |
| panHwShelfNetCardSerialNETCARD (aka Switch Card) serial number. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.1.4.1.2 |
panHwShelfNetCardModelNumberobsolete NETCARD (aka Switch Card) model number. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.1.4.1.3 |
| panHwShelfNetCardModelNameNETCARD (aka Switch Card) model name. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.1.4.1.4 |
panHwShelfNetCardNumPortsobsolete Number of ports in NETCARD (aka Switch Card). | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.10159.1.2.1.4.1.5 |
.1.3.6.1.4.1.10159.1.2.1.5
·
1 row entry
·
2 columns
Uses the panasas variant from
Command help
/opt/observium/mibs/panasas.
Walk panHwShelfErrorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PANASAS-HW-MIB-V1' -M '/opt/observium/mibs/panasas:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PANASAS-HW-MIB-V1::panHwShelfErrorTable'
Extends panHwShelfTable. Lists the errors associated with a shelf. NOTE: This table is obsoleted.
An entry in panHwShelfErrorTable.
Indexes
| Column | Syntax | OID |
|---|---|---|
panHwShelfErrorIndexobsolete An index into panHwShelfErrorTable | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.10159.1.2.1.5.1.1 |
panHwShelfErrorInfoobsolete Textual description of the error. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.1.5.1.2 |
panHwShelfSlotTable
table.1.3.6.1.4.1.10159.1.2.1.6
·
1 row entry
·
2 columns
Uses the panasas variant from
Command help
/opt/observium/mibs/panasas.
Walk panHwShelfSlotTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PANASAS-HW-MIB-V1' -M '/opt/observium/mibs/panasas:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PANASAS-HW-MIB-V1::panHwShelfSlotTable'
Extends panHwShelfTable. Table listing the blades in each slot of a shelf.
An entry in panHwShelfSlotTable.
Indexes
| Column | Syntax | OID |
|---|---|---|
| panHwShelfSlotSlot number and an index into panHwShelfSlotTable. | Integer32 Constraints: range: 1-15 | .1.3.6.1.4.1.10159.1.2.1.6.1.1 |
| panHwShelfSlotBladeHwSNHardware serial number of blade in the slot. It is also an index into panHwBladeTable. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.1.6.1.2 |
panHwBladeTable
table.1.3.6.1.4.1.10159.1.2.2.1
·
1 row entry
·
26 columns
Uses the panasas variant from
Command help
/opt/observium/mibs/panasas.
Walk panHwBladeTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PANASAS-HW-MIB-V1' -M '/opt/observium/mibs/panasas:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PANASAS-HW-MIB-V1::panHwBladeTable'
Table of blades in the system. NOTE: The panHwBladeUpTime attribute is obsoleted.
An entry in panHwBladeTable.
Indexes
| Column | Syntax | OID |
|---|---|---|
| panHwBladeHwSNIndex into panHwBladeTable. Factory assigned unique Hardware Serial Number of blade. NOTE: For blades of type (panHwBladeType) OSD there is no hardware serial number since they are Virtual OSDs. So, the value of panHwB… | PANASAS-TC-MIBPanSerialNumber Type Constraints: range: 8..32 | .1.3.6.1.4.1.10159.1.2.2.1.1.1 |
| panHwBladeTypeBlade type (DirectorBlade, StorageBlade, StorageServer, OSD (virtual osd)). | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.2.1.1.2 |
| panHwBladeModelNumberBlade model number. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.2.1.1.3 |
| panHwBladeModelNameBlade model name. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.2.1.1.4 |
| panHwBladeBIOSRevBlade's BIOS Revision | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.2.1.1.5 |
| panHwBladeBIOSDateBlade's BIOS Date | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.2.1.1.6 |
| panHwBladeHWRevBlade's Hardware Revision | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.2.1.1.7 |
| panHwBladeProgramingModelBlade's Programming Model. This identifies to software the format of CMOS etc. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.2.1.1.8 |
| panHwBladeSWVersionBlade's Software Version executing on the blade. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.2.1.1.9 |
| panHwBladeMemoryAmount of system memory (RAM) in MB. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.10159.1.2.2.1.1.10 |
| panHwBladeNumCpuNumber of physical CPU's. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.10159.1.2.2.1.1.11 |
| panHwBladeCpuTypeType of CPU. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.2.1.1.12 |
| panHwBladeInfoSystem level status of the blade. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.2.1.1.13 |
| panHwBladeDataSNUnique Data Serial Number of blade assigned after initialization. This changes whenever the blade is initialized. NOTE: For blades of type (panHwBladeType) OSD this is used to derive the value for panHwBladeHwSN. | PANASAS-TC-MIBPanSerialNumber Type Constraints: range: 8..32 | .1.3.6.1.4.1.10159.1.2.2.1.1.14 |
| panHwBladeBSetNameBladeset the blade is a member off. It is also an index into panBSetTable. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.2.1.1.15 |
| panHwBladeShelfSNShelf the blade is in. It is also an index into panHwShelfTable. | PANASAS-TC-MIBPanSerialNumber Type Constraints: range: 8..32 | .1.3.6.1.4.1.10159.1.2.2.1.1.16 |
| panHwBladeSlotShelf slot the blade is in. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.10159.1.2.2.1.1.17 |
panHwBladeUpTimeobsolete How long the blade has been up. | SNMPv2-SMITimeTicks Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.10159.1.2.2.1.1.18 |
| panHwBladeRaidRAID type supported by this component. Possible values: Block RAID5, Block RAID6, Mixed, Object RAID or Unknown | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.2.1.1.19 |
| panHwBladeControllerSNSerial number of controller associated with this blade. This is applicable for blades of types StorageServer and OSD. | PANASAS-TC-MIBPanSerialNumber Type Constraints: range: 8..32 | .1.3.6.1.4.1.10159.1.2.2.1.1.20 |
| panHwBladeControllerNameName of controller associated with this blade. This is applicable for blades of types StorageServer and OSD. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.2.1.1.21 |
| panHwBladeIpmiFwRevIPMI firmware revision number. This is applicable for blades of type StorageServer only. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.2.1.1.22 |
| panHwBladeIpmiIpAddr1IPV4 address #1 of IPMI. This is applicable for blades of type StorageServer only. | SNMPv2-SMIIpAddress Type Constraints: range: 4 | .1.3.6.1.4.1.10159.1.2.2.1.1.23 |
| panHwBladeOsdStorageServerNameName of the Storage Server serving this blade. This is applicable for blades of type OSD. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.2.1.1.24 |
| panHwBladeOsdControllerLunNumThe lun number assigned to this OSD from the controller. This is applicable for blades of type OSD. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.2.1.1.25 |
| panHwBladeNameThe name assigned to this component. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.2.1.1.26 |
panHwBladeIfTable
table.1.3.6.1.4.1.10159.1.2.2.2
·
1 row entry
·
9 columns
Uses the panasas variant from
Command help
/opt/observium/mibs/panasas.
Walk panHwBladeIfTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PANASAS-HW-MIB-V1' -M '/opt/observium/mibs/panasas:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PANASAS-HW-MIB-V1::panHwBladeIfTable'
Extends the panHwBladeTable and lists all the interfaces on a blade. NOTE: This table is obsoleted.
An entry in panHwBladeIfTable.
Indexes
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| panHwBladeIfIndexAn index into panHwBladeIfTable. | Integer32 Constraints: range: 0-5 | .1.3.6.1.4.1.10159.1.2.2.2.1.1 | ||||||||||
| panHwBladeIfNameName of the interface. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.2.2.1.2 | ||||||||||
| panHwBladeIfTypeValues match ifType in IF-MIB. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.10159.1.2.2.2.1.3 | ||||||||||
panHwBladeIfPhysAddressobsolete The interface's address at its protocol sub-layer. | SNMPv2-TCPhysAddress Description: Represents media- or physical-level addresses. | .1.3.6.1.4.1.10159.1.2.2.2.1.4 | ||||||||||
panHwBladeIfSpeedobsolete Current operational speed of the interface. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.10159.1.2.2.2.1.5 | ||||||||||
panHwBladeIfAdminStatusobsolete Administrative state of the interface.Values match ifAdminStatus in IF-MIB. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.10159.1.2.2.2.1.6 | ||||||||||
panHwBladeIfOperStatusobsolete Operational state of the interface.Values match ifOperStatus in IF-MIB. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.10159.1.2.2.2.1.7 | ||||||||||
| panHwBladeIfStatusThe current status of this NIC. One of active, standby, inactive, uplinkdown or unknown. Defaults to unknown. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.10159.1.2.2.2.1.9 | ||||||||||
| panHwBladeIfNetworkUse of this NIC to access network - either primary, secondary or unknown. Defaults to unknown. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.10159.1.2.2.2.1.10 |
panHwBladeIpAddrTable
table.1.3.6.1.4.1.10159.1.2.2.3
·
1 row entry
·
2 columns
Uses the panasas variant from
Command help
/opt/observium/mibs/panasas.
Walk panHwBladeIpAddrTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PANASAS-HW-MIB-V1' -M '/opt/observium/mibs/panasas:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PANASAS-HW-MIB-V1::panHwBladeIpAddrTable'
Extends the panHwBladeTable and lists all the IP Address assigned to a blade.
An entry in panHwBladeIpAddrTable.
Indexes
| Column | Syntax | OID |
|---|---|---|
| panHwBladeIpAddrIndex into panHwBladeIpAddrTable. | SNMPv2-SMIIpAddress Type Constraints: range: 4 | .1.3.6.1.4.1.10159.1.2.2.3.1.1 |
| panHwBladeIpAddrIfIndexInterface identified by panHwBladeIfIndex. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.10159.1.2.2.3.1.2 |
panHwBladeDiskTable
table.1.3.6.1.4.1.10159.1.2.2.5
·
1 row entry
·
8 columns
Uses the panasas variant from
Command help
/opt/observium/mibs/panasas.
Walk panHwBladeDiskTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PANASAS-HW-MIB-V1' -M '/opt/observium/mibs/panasas:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PANASAS-HW-MIB-V1::panHwBladeDiskTable'
Extends the panHwBladeTable and lists all the disk drives connected to a blade. NOTE: The panHwBladeDiskSpeed attribute is obsoleted.
An entry in panHwBladeDiskTable.
Indexes
| Column | Syntax | OID |
|---|---|---|
| panHwBladeDiskIndexAn index into panHwBladeDiskTable. The value of this is the integer part of the device name. Ex. if device name is ad2, the index will be 2 | Integer32 Constraints: range: 0-32 | .1.3.6.1.4.1.10159.1.2.2.5.1.1 |
| panHwBladeDiskCapacityCapacity of the disk in Giga Bytes (GB). | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.10159.1.2.2.5.1.2 |
panHwBladeDiskSpeedobsolete Speed of the disk in RPM. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.2.5.1.3 |
| panHwBladeDiskVendorDisk vendor information. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.2.5.1.4 |
| panHwBladeDiskModelDisk Model information. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.2.5.1.5 |
| panHwBladeDiskFirmwareDisk firmware information. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.2.5.1.6 |
| panHwBladeDiskSerialSerial number of the disk. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.2.5.1.7 |
| panHwBladeDiskNameDevice name of the disk. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.2.5.1.8 |
.1.3.6.1.4.1.10159.1.2.2.6
·
1 row entry
·
2 columns
Uses the panasas variant from
Command help
/opt/observium/mibs/panasas.
Walk panHwBladeErrorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PANASAS-HW-MIB-V1' -M '/opt/observium/mibs/panasas:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PANASAS-HW-MIB-V1::panHwBladeErrorTable'
Extends the panHwBladeTable and lists errors for a blade. NOTE: This table is obsolete.
An entry in panHwBladeErrorTable.
Indexes
| Column | Syntax | OID |
|---|---|---|
panHwBladeErrorIndexobsolete An index into panHwBladeErrorTable. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.10159.1.2.2.6.1.1 |
panHwBladeErrorInfoobsolete Textual description of the error. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.2.6.1.2 |
panHwBladeFcPortTable
table.1.3.6.1.4.1.10159.1.2.2.8
·
1 row entry
·
6 columns
Uses the panasas variant from
Command help
/opt/observium/mibs/panasas.
Walk panHwBladeFcPortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PANASAS-HW-MIB-V1' -M '/opt/observium/mibs/panasas:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PANASAS-HW-MIB-V1::panHwBladeFcPortTable'
Extends the panHwBladeTable and lists all the information about fiber channel ports in the blade.
An entry in panHwBladeFcPortTable.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
| panHwBladeFcPortNumberThe FC Port number. An index into panHwBladeFcPortTable. | Integer32 Constraints: range: 0-32 | .1.3.6.1.4.1.10159.1.2.2.8.1.1 | ||||||
| panHwBladeFcPortWWPNThe World Wide Port Name of this FC Port. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.2.8.1.2 | ||||||
| panHwBladeFcPortDeviceNameDevice name of the FC Port. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.2.8.1.3 | ||||||
| panHwBladeFcPortDeviceModelThe model name of the HBA of this port. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.2.8.1.4 | ||||||
| panHwBladeFcPortSpeedSpeed in Mb/second of the FC Port. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.2.8.1.5 | ||||||
| panHwBladeFcPortStatusStatus of the FC Port. One of active, inactive or unknown. Defaults to unknown. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.10159.1.2.2.8.1.6 |
.1.3.6.1.4.1.10159.1.2.3
·
1 row entry
·
6 columns
Uses the panasas variant from
Command help
/opt/observium/mibs/panasas.
Walk panHwTemperatureTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PANASAS-HW-MIB-V1' -M '/opt/observium/mibs/panasas:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PANASAS-HW-MIB-V1::panHwTemperatureTable'
The temperature table details the temparature at various sensors on different hardware components. NOTE: This table is obsolete.
Temperature sensor reading
| Column | Syntax | OID |
|---|---|---|
panHwTemperatureComponentobsolete Secondary index into panHwTemperatureTable, | ObjectIdentifier | .1.3.6.1.4.1.10159.1.2.3.1.1 |
panHwTemperatureIndexobsolete Primary index into panHwTemperatureTable,It is the SNMP OID for an object in the panHw OID space, and it is used to identify the HW component where the sensor is located (e.g. shelf, power supply, blade etc.). | Integer32 Constraints: range: 0-10 | .1.3.6.1.4.1.10159.1.2.3.1.2 |
panHwTemperatureLocationobsolete Description of the sensor's location on the HW component. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.3.1.3 |
panHwTemperatureOperMinobsolete Minimum temparature that this sensor can report. | PANASAS-TC-MIBPanTemperature Type Constraints: range: -100..200 | .1.3.6.1.4.1.10159.1.2.3.1.4 |
panHwTemperatureOperMaxobsolete Maximum temparature that this sensor can report. | PANASAS-TC-MIBPanTemperature Type Constraints: range: -100..200 | .1.3.6.1.4.1.10159.1.2.3.1.5 |
panHwTemperatureCurrentobsolete Current temparature reported by this sensor. | PANASAS-TC-MIBPanTemperature Type Constraints: range: -100..200 | .1.3.6.1.4.1.10159.1.2.3.1.6 |
.1.3.6.1.4.1.10159.1.2.4
·
1 row entry
·
2 columns
Uses the panasas variant from
Command help
/opt/observium/mibs/panasas.
Walk panHwIpAddrTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PANASAS-HW-MIB-V1' -M '/opt/observium/mibs/panasas:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PANASAS-HW-MIB-V1::panHwIpAddrTable'
Table to map IP Addresses to Blades. NOTE: This is table is obsoleted.
An entry in panHwIpAddrTable.
Indexes
| Column | Syntax | OID |
|---|---|---|
panHwIpAddrobsolete Index into panHwIpAddrTable. | SNMPv2-SMIIpAddress Type Constraints: range: 4 | .1.3.6.1.4.1.10159.1.2.4.1.1 |
panHwIpAddrBladeHwSNobsolete Blade HW Serial Number (an index into panHwBladeTable). | PANASAS-TC-MIBPanSerialNumber Type Constraints: range: 8..32 | .1.3.6.1.4.1.10159.1.2.4.1.2 |
panHwControllerTable
table.1.3.6.1.4.1.10159.1.2.5.1
·
1 row entry
·
4 columns
Uses the panasas variant from
Command help
/opt/observium/mibs/panasas.
Walk panHwControllerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PANASAS-HW-MIB-V1' -M '/opt/observium/mibs/panasas:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PANASAS-HW-MIB-V1::panHwControllerTable'
The main controller table. This table is extended by other tables that describe controller resources like drives.
Controller Hardware Information
Indexes
| Column | Syntax | OID |
|---|---|---|
| panHwControllerSNFactory assigned unique Serial Number of a controller and an index into panHwControllerTable. | PANASAS-TC-MIBPanSerialNumber Type Constraints: range: 8..32 | .1.3.6.1.4.1.10159.1.2.5.1.1.1 |
| panHwControllerNameName assigned to the controller. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.5.1.1.2 |
| panHwControllerFirmwareRevController's firmware revision. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.5.1.1.3 |
| panHwControllerNvsramRevController's nvsram revision. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.5.1.1.4 |
panHwControllerOsdTable
table.1.3.6.1.4.1.10159.1.2.5.2
·
1 row entry
·
2 columns
Uses the panasas variant from
Command help
/opt/observium/mibs/panasas.
Walk panHwControllerOsdTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PANASAS-HW-MIB-V1' -M '/opt/observium/mibs/panasas:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PANASAS-HW-MIB-V1::panHwControllerOsdTable'
Extends panHwControllerTable.. Table listing the OSDs controlled by the controller.
An entry in panHwControllerOsdTable.
| Column | Syntax | OID |
|---|---|---|
| panHwControllerOsdLunNumThe lun number managed by this OSD. This is an index into this table. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.10159.1.2.5.2.1.1 |
| panHwControllerOsdNameOSD's name. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.5.2.1.2 |
.1.3.6.1.4.1.10159.1.2.5.3
·
1 row entry
·
2 columns
Uses the panasas variant from
Command help
/opt/observium/mibs/panasas.
Walk panHwControllerStorageServerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PANASAS-HW-MIB-V1' -M '/opt/observium/mibs/panasas:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PANASAS-HW-MIB-V1::panHwControllerStorageServerTable'
Extends panHwControllerTable.. Table listing the Storage Servers associated with the controller.
An entry in panHwControllerStorageServerTable.
| Column | Syntax | OID |
|---|---|---|
| panHwControllerStorageServerSNThis is the StorageServer's hardware serial number, which is the same as panHwBladeHwSN of the panHwBladeTable. This is an index into this table. | PANASAS-TC-MIBPanSerialNumber Type Constraints: range: 8..32 | .1.3.6.1.4.1.10159.1.2.5.3.1.1 |
| panHwControllerStorageServerNameStorage server's name. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.5.3.1.2 |
.1.3.6.1.4.1.10159.1.2.5.4
·
1 row entry
·
12 columns
Uses the panasas variant from
Command help
/opt/observium/mibs/panasas.
Walk panHwControllerDriveTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PANASAS-HW-MIB-V1' -M '/opt/observium/mibs/panasas:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PANASAS-HW-MIB-V1::panHwControllerDriveTable'
Extends panHwControllerTable.. Table listing the drives controlled by the controller.
An entry in panHwShelfSlotTable.
| Column | Syntax | OID |
|---|---|---|
| panHwControllerDriveDrawerThe location of a drive is uniquely identified by its drawer number, tray number and slot number. This is the drawer number. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.10159.1.2.5.4.1.1 |
| panHwControllerDriveTrayThe location of a drive is uniquely identified by its drawer number, tray number and slot number. This is the tray number. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.10159.1.2.5.4.1.2 |
| panHwControllerDriveSlotThe location of a drive is uniquely identified by its drawer number, tray number and slot number. This is the slot number. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.10159.1.2.5.4.1.3 |
| panHwControllerDriveSNSerial number of the drive. | PANASAS-TC-MIBPanSerialNumber Type Constraints: range: 8..32 | .1.3.6.1.4.1.10159.1.2.5.4.1.4 |
| panHwControllerDriveVendorVendor name of the drive. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.5.4.1.5 |
| panHwControllerDriveModelModel number of the drive. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.5.4.1.6 |
| panHwControllerDriveFirmwareRevFirmware revision of the drive. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.5.4.1.7 |
| panHwControllerDriveTypeType of drive. Possible values are SSD, SATA, SAS, FC and Unknown. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.5.4.1.8 |
| panHwControllerDriveTotalCapacityToal capacity in GB of drive. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.10159.1.2.5.4.1.9 |
| panHwControllerDriveFormattedIndicates if drives is formatted or not. A value of panTrue indicates the drive is formatted. | .1.3.6.1.4.1.10159.1.2.5.4.1.10 | |
| panHwControllerDriveFailedIndicates if drive had failed. A value of panTrue indicates failure. | .1.3.6.1.4.1.10159.1.2.5.4.1.11 | |
| panHwControllerDriveHotSpareIndicates if drive is a hot spare. A value of panTrue means the drive is a hot spare . | .1.3.6.1.4.1.10159.1.2.5.4.1.12 |