PANASAS-HW-MIB-V1 Table View

Table-centric layout grouping table, row, and column objects.

Tables
18
Rows
18
Columns
109
.1.3.6.1.4.1.10159.1.2.1.1 · 1 row entry · 5 columns
Uses the panasas variant from /opt/observium/mibs/panasas.
Command help
Walk panHwShelfTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PANASAS-HW-MIB-V1' -M '/opt/observium/mibs/panasas:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PANASAS-HW-MIB-V1::panHwShelfTable'
The ShelfTable.
This table is extended by several tables that describe
shelf resources.
panHwShelfEntry row .1.3.6.1.4.1.10159.1.2.1.1.1
Shelf Hardware Information
Indexes
Column Syntax OID
panHwShelfSNFactory assigned unique Serial Number of a shelf and an
index into panHwShelfTable.
PANASAS-TC-MIBPanSerialNumber
Type Constraints:
range: 8..32
.1.3.6.1.4.1.10159.1.2.1.1.1.1
Model number of shelf.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.1.1.1.2
Shelf's model name.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.1.1.1.3
panHwShelfHwRevShelf's hardware revision.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.1.1.1.4
panHwShelfNameAdministrator assigned name for a shelf.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.1.1.1.5
.1.3.6.1.4.1.10159.1.2.1.2 · 1 row entry · 8 columns
Uses the panasas variant from /opt/observium/mibs/panasas.
Command help
Walk panHwShelfPSTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PANASAS-HW-MIB-V1' -M '/opt/observium/mibs/panasas:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PANASAS-HW-MIB-V1::panHwShelfPSTable'
Extends panHwShelfTable.
Lists the power supplies in a shelf.
NOTE: several attributes have been obsoleted.
panHwShelfPSEntry row .1.3.6.1.4.1.10159.1.2.1.2.1
An entry in panHwShelfPSTable.
Column Syntax OID
panHwShelfPSIndexIndex into panHwShelfPSTable.Integer32
Constraints:
range: 1-5
.1.3.6.1.4.1.10159.1.2.1.2.1.1
panHwShelfPSSerialPower supply serial number.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.1.2.1.2
Power supply model number.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.1.2.1.3
Power supply model name.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.1.2.1.4
Status of AC Voltage to power supply.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.1.2.1.5
Status of 12.0 Voltage from power supply.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.1.2.1.6
Status of 5.0 Voltage from power supply.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.1.2.1.7
Status of 3.3 Voltage from power supply.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.1.2.1.8
.1.3.6.1.4.1.10159.1.2.1.3 · 1 row entry · 6 columns
Uses the panasas variant from /opt/observium/mibs/panasas.
Command help
Walk panHwShelfBatteryTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PANASAS-HW-MIB-V1' -M '/opt/observium/mibs/panasas:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PANASAS-HW-MIB-V1::panHwShelfBatteryTable'
Extends panHwShelfTable.
Lists the batteries in a shelf.
panHwShelfBatteryEntry row .1.3.6.1.4.1.10159.1.2.1.3.1
An entry in panHwShelfBatteryTable.
Column Syntax OID
panHwShelfBatteryIndexAn index into panHwShelfBatteryTable.Integer32
Constraints:
range: 1-5
.1.3.6.1.4.1.10159.1.2.1.3.1.1
panHwShelfBatterySerialBattery serial number.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.1.3.1.2
Battery model number.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.1.3.1.3
panHwShelfBatteryModelNameBattery model name.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.1.3.1.4
Status of battery voltage.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.1.3.1.5
Current state of battery.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.1.3.1.6
.1.3.6.1.4.1.10159.1.2.1.4 · 1 row entry · 5 columns
Uses the panasas variant from /opt/observium/mibs/panasas.
Command help
Walk panHwShelfNetCardTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PANASAS-HW-MIB-V1' -M '/opt/observium/mibs/panasas:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PANASAS-HW-MIB-V1::panHwShelfNetCardTable'
Extends panHwShelfTable.
Lists the NETCARD (aka Network Switch cards) in a shelf.
panHwShelfNetCardEntry row .1.3.6.1.4.1.10159.1.2.1.4.1
Entry in panHwShelfNetCardTable.
Column Syntax OID
panHwShelfNetCardIndexAn index into panHwShelfNetCardTable.Integer32
Constraints:
range: 1-5
.1.3.6.1.4.1.10159.1.2.1.4.1.1
panHwShelfNetCardSerialNETCARD (aka Switch Card) serial number.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.1.4.1.2
NETCARD (aka Switch Card) model number.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.1.4.1.3
panHwShelfNetCardModelNameNETCARD (aka Switch Card) model name.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.1.4.1.4
Number of ports in NETCARD (aka Switch Card).Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10159.1.2.1.4.1.5

panHwShelfErrorTable

table obsolete
.1.3.6.1.4.1.10159.1.2.1.5 · 1 row entry · 2 columns
Uses the panasas variant from /opt/observium/mibs/panasas.
Command help
Walk panHwShelfErrorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PANASAS-HW-MIB-V1' -M '/opt/observium/mibs/panasas:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PANASAS-HW-MIB-V1::panHwShelfErrorTable'
Extends panHwShelfTable.
Lists the errors associated with a shelf.
NOTE: This table is obsoleted.
panHwShelfErrorEntry row .1.3.6.1.4.1.10159.1.2.1.5.1
An entry in panHwShelfErrorTable.
Column Syntax OID
An index into panHwShelfErrorTableSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.10159.1.2.1.5.1.1
Textual description of the error.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.1.5.1.2
.1.3.6.1.4.1.10159.1.2.1.6 · 1 row entry · 2 columns
Uses the panasas variant from /opt/observium/mibs/panasas.
Command help
Walk panHwShelfSlotTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PANASAS-HW-MIB-V1' -M '/opt/observium/mibs/panasas:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PANASAS-HW-MIB-V1::panHwShelfSlotTable'
Extends panHwShelfTable.
Table listing the blades in each slot of a shelf.
panHwShelfSlotEntry row .1.3.6.1.4.1.10159.1.2.1.6.1
An entry in panHwShelfSlotTable.
Column Syntax OID
panHwShelfSlotSlot number and an index into panHwShelfSlotTable.Integer32
Constraints:
range: 1-15
.1.3.6.1.4.1.10159.1.2.1.6.1.1
panHwShelfSlotBladeHwSNHardware serial number of blade in the slot.
It is also an index into panHwBladeTable.
RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.1.6.1.2
.1.3.6.1.4.1.10159.1.2.2.1 · 1 row entry · 26 columns
Uses the panasas variant from /opt/observium/mibs/panasas.
Command help
Walk panHwBladeTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PANASAS-HW-MIB-V1' -M '/opt/observium/mibs/panasas:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PANASAS-HW-MIB-V1::panHwBladeTable'
Table of blades in the system.
NOTE: The panHwBladeUpTime attribute 
is obsoleted.
panHwBladeEntry row .1.3.6.1.4.1.10159.1.2.2.1.1
An entry in panHwBladeTable.
Indexes
Column Syntax OID
panHwBladeHwSNIndex into panHwBladeTable.
Factory assigned unique Hardware Serial Number of blade.
NOTE: For blades of type (panHwBladeType) OSD
there is no hardware serial number since they are
Virtual OSDs. So, the value of panHwB…
PANASAS-TC-MIBPanSerialNumber
Type Constraints:
range: 8..32
.1.3.6.1.4.1.10159.1.2.2.1.1.1
panHwBladeTypeBlade type (DirectorBlade, StorageBlade,
StorageServer, OSD (virtual osd)).
RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.2.1.1.2
panHwBladeModelNumberBlade model number.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.2.1.1.3
panHwBladeModelNameBlade model name.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.2.1.1.4
panHwBladeBIOSRevBlade's BIOS RevisionRFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.2.1.1.5
panHwBladeBIOSDateBlade's BIOS DateRFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.2.1.1.6
panHwBladeHWRevBlade's Hardware RevisionRFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.2.1.1.7
panHwBladeProgramingModelBlade's Programming Model. This identifies to software
the format of CMOS etc.
RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.2.1.1.8
panHwBladeSWVersionBlade's Software Version executing on the blade.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.2.1.1.9
panHwBladeMemoryAmount of system memory (RAM) in MB.SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.10159.1.2.2.1.1.10
panHwBladeNumCpuNumber of physical CPU's.SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.10159.1.2.2.1.1.11
panHwBladeCpuTypeType of CPU.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.2.1.1.12
panHwBladeInfoSystem level status of the blade.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.2.1.1.13
panHwBladeDataSNUnique Data Serial Number of blade assigned after
initialization. This changes whenever the blade is
initialized.
NOTE: For blades of type (panHwBladeType) OSD
this is used to derive the value for panHwBladeHwSN.
PANASAS-TC-MIBPanSerialNumber
Type Constraints:
range: 8..32
.1.3.6.1.4.1.10159.1.2.2.1.1.14
panHwBladeBSetNameBladeset the blade is a member off. It is also
an index into panBSetTable.
RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.2.1.1.15
panHwBladeShelfSNShelf the blade is in. It is also an index
into panHwShelfTable.
PANASAS-TC-MIBPanSerialNumber
Type Constraints:
range: 8..32
.1.3.6.1.4.1.10159.1.2.2.1.1.16
panHwBladeSlotShelf slot the blade is in.SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.10159.1.2.2.1.1.17
How long the blade has been up.SNMPv2-SMITimeTicks
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.10159.1.2.2.1.1.18
panHwBladeRaidRAID type supported by this component.
Possible values:
Block RAID5, Block RAID6, Mixed, Object RAID or Unknown
RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.2.1.1.19
panHwBladeControllerSNSerial number of controller associated with this blade.
This is applicable for blades of types
StorageServer and OSD.
PANASAS-TC-MIBPanSerialNumber
Type Constraints:
range: 8..32
.1.3.6.1.4.1.10159.1.2.2.1.1.20
panHwBladeControllerNameName of controller associated with this blade.
This is applicable for blades of types
StorageServer and OSD.
RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.2.1.1.21
panHwBladeIpmiFwRevIPMI firmware revision number.
This is applicable for blades of type
StorageServer only.
RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.2.1.1.22
panHwBladeIpmiIpAddr1IPV4 address #1 of IPMI.
This is applicable for blades of type
StorageServer only.
SNMPv2-SMIIpAddress
Type Constraints:
range: 4
.1.3.6.1.4.1.10159.1.2.2.1.1.23
panHwBladeOsdStorageServerNameName of the Storage Server serving this blade.
This is applicable for blades of type OSD.
RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.2.1.1.24
panHwBladeOsdControllerLunNumThe lun number assigned to this OSD from the controller.
This is applicable for blades of type OSD.
RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.2.1.1.25
panHwBladeNameThe name assigned to this component.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.2.1.1.26
.1.3.6.1.4.1.10159.1.2.2.2 · 1 row entry · 9 columns
Uses the panasas variant from /opt/observium/mibs/panasas.
Command help
Walk panHwBladeIfTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PANASAS-HW-MIB-V1' -M '/opt/observium/mibs/panasas:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PANASAS-HW-MIB-V1::panHwBladeIfTable'
Extends the panHwBladeTable and lists all the
interfaces on a blade.
NOTE: This table is obsoleted.
panHwBladeIfEntry row .1.3.6.1.4.1.10159.1.2.2.2.1
An entry in panHwBladeIfTable.
Column Syntax OID
panHwBladeIfIndexAn index into panHwBladeIfTable.Integer32
Constraints:
range: 0-5
.1.3.6.1.4.1.10159.1.2.2.2.1.1
panHwBladeIfNameName of the interface.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.2.2.1.2
panHwBladeIfTypeValues match ifType in IF-MIB.Enumeration
Enumerated Values:
1other
6ethernet-csmacd
23ppp
24softwareLoopback
.1.3.6.1.4.1.10159.1.2.2.2.1.3
The interface's address at its protocol sub-layer.SNMPv2-TCPhysAddress
Description:
Represents media- or physical-level addresses.
.1.3.6.1.4.1.10159.1.2.2.2.1.4
Current operational speed of the interface.Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10159.1.2.2.2.1.5
Administrative state of the interface.
Values match ifAdminStatus in IF-MIB.
Enumeration
Enumerated Values:
1up
2down
3testing
.1.3.6.1.4.1.10159.1.2.2.2.1.6
Operational state of the interface.
Values match ifOperStatus in IF-MIB.
Enumeration
Enumerated Values:
1up
2down
3testing
.1.3.6.1.4.1.10159.1.2.2.2.1.7
panHwBladeIfStatusThe current status of this NIC.
One of active, standby, inactive, uplinkdown or unknown.
Defaults to unknown.
Enumeration
Enumerated Values:
1active
2standby
3inactive
4uplinkdown
5unknown
.1.3.6.1.4.1.10159.1.2.2.2.1.9
panHwBladeIfNetworkUse of this NIC to access network - either
primary, secondary or unknown.
Defaults to unknown.
Enumeration
Enumerated Values:
1primary
2secondary
3unknown
.1.3.6.1.4.1.10159.1.2.2.2.1.10
.1.3.6.1.4.1.10159.1.2.2.3 · 1 row entry · 2 columns
Uses the panasas variant from /opt/observium/mibs/panasas.
Command help
Walk panHwBladeIpAddrTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PANASAS-HW-MIB-V1' -M '/opt/observium/mibs/panasas:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PANASAS-HW-MIB-V1::panHwBladeIpAddrTable'
Extends the panHwBladeTable and lists all the
IP Address assigned to a blade.
panHwBladeIpAddrEntry row .1.3.6.1.4.1.10159.1.2.2.3.1
An entry in panHwBladeIpAddrTable.
Column Syntax OID
panHwBladeIpAddrIndex into panHwBladeIpAddrTable.SNMPv2-SMIIpAddress
Type Constraints:
range: 4
.1.3.6.1.4.1.10159.1.2.2.3.1.1
panHwBladeIpAddrIfIndexInterface identified by panHwBladeIfIndex.SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.10159.1.2.2.3.1.2
.1.3.6.1.4.1.10159.1.2.2.5 · 1 row entry · 8 columns
Uses the panasas variant from /opt/observium/mibs/panasas.
Command help
Walk panHwBladeDiskTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PANASAS-HW-MIB-V1' -M '/opt/observium/mibs/panasas:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PANASAS-HW-MIB-V1::panHwBladeDiskTable'
Extends the panHwBladeTable and lists all the
disk drives connected to a blade.
NOTE: The panHwBladeDiskSpeed attribute is obsoleted.
panHwBladeDiskEntry row .1.3.6.1.4.1.10159.1.2.2.5.1
An entry in panHwBladeDiskTable.
Column Syntax OID
panHwBladeDiskIndexAn index into panHwBladeDiskTable.
The value of this is the integer part of the device name.
Ex. if device name is ad2, the index will be 2
Integer32
Constraints:
range: 0-32
.1.3.6.1.4.1.10159.1.2.2.5.1.1
panHwBladeDiskCapacityCapacity of the disk in Giga Bytes (GB).Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10159.1.2.2.5.1.2
Speed of the disk in RPM.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.2.5.1.3
panHwBladeDiskVendorDisk vendor information.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.2.5.1.4
panHwBladeDiskModelDisk Model information.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.2.5.1.5
panHwBladeDiskFirmwareDisk firmware information.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.2.5.1.6
panHwBladeDiskSerialSerial number of the disk.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.2.5.1.7
panHwBladeDiskNameDevice name of the disk.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.2.5.1.8

panHwBladeErrorTable

table obsolete
.1.3.6.1.4.1.10159.1.2.2.6 · 1 row entry · 2 columns
Uses the panasas variant from /opt/observium/mibs/panasas.
Command help
Walk panHwBladeErrorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PANASAS-HW-MIB-V1' -M '/opt/observium/mibs/panasas:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PANASAS-HW-MIB-V1::panHwBladeErrorTable'
Extends the panHwBladeTable and lists errors for a blade.
NOTE: This table is obsolete.
panHwBladeErrorEntry row .1.3.6.1.4.1.10159.1.2.2.6.1
An entry in panHwBladeErrorTable.
Column Syntax OID
An index into panHwBladeErrorTable.SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.10159.1.2.2.6.1.1
Textual description of the error.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.2.6.1.2
.1.3.6.1.4.1.10159.1.2.2.8 · 1 row entry · 6 columns
Uses the panasas variant from /opt/observium/mibs/panasas.
Command help
Walk panHwBladeFcPortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PANASAS-HW-MIB-V1' -M '/opt/observium/mibs/panasas:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PANASAS-HW-MIB-V1::panHwBladeFcPortTable'
Extends the panHwBladeTable and lists all the
information about fiber channel ports in the blade.
panHwBladeFcPortEntry row .1.3.6.1.4.1.10159.1.2.2.8.1
An entry in panHwBladeFcPortTable.
Column Syntax OID
panHwBladeFcPortNumberThe FC Port number.
An index into panHwBladeFcPortTable.
Integer32
Constraints:
range: 0-32
.1.3.6.1.4.1.10159.1.2.2.8.1.1
panHwBladeFcPortWWPNThe World Wide Port Name of this FC Port.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.2.8.1.2
panHwBladeFcPortDeviceNameDevice name of the FC Port.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.2.8.1.3
panHwBladeFcPortDeviceModelThe model name of the HBA of this port.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.2.8.1.4
panHwBladeFcPortSpeedSpeed in Mb/second of the FC Port.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.2.8.1.5
panHwBladeFcPortStatusStatus of the FC Port.
One of active, inactive or unknown.
Defaults to unknown.
Enumeration
Enumerated Values:
1active
2inactive
3unknown
.1.3.6.1.4.1.10159.1.2.2.8.1.6

panHwTemperatureTable

table obsolete
.1.3.6.1.4.1.10159.1.2.3 · 1 row entry · 6 columns
Uses the panasas variant from /opt/observium/mibs/panasas.
Command help
Walk panHwTemperatureTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PANASAS-HW-MIB-V1' -M '/opt/observium/mibs/panasas:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PANASAS-HW-MIB-V1::panHwTemperatureTable'
The temperature table details the temparature at various
sensors on different hardware components.
NOTE: This table is obsolete.
panHwTemperatureEntry row .1.3.6.1.4.1.10159.1.2.3.1
Temperature sensor reading
Column Syntax OID
Secondary index into panHwTemperatureTable,ObjectIdentifier.1.3.6.1.4.1.10159.1.2.3.1.1
Primary index into panHwTemperatureTable,
It is the SNMP OID for an object in the panHw OID space,
and it is used to identify the HW component where the sensor
is located (e.g. shelf, power supply, blade etc.).
Integer32
Constraints:
range: 0-10
.1.3.6.1.4.1.10159.1.2.3.1.2
Description of the sensor's location on the HW component.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.3.1.3
Minimum temparature that this sensor can report.PANASAS-TC-MIBPanTemperature
Type Constraints:
range: -100..200
.1.3.6.1.4.1.10159.1.2.3.1.4
Maximum temparature that this sensor can report.PANASAS-TC-MIBPanTemperature
Type Constraints:
range: -100..200
.1.3.6.1.4.1.10159.1.2.3.1.5
Current temparature reported by this sensor.PANASAS-TC-MIBPanTemperature
Type Constraints:
range: -100..200
.1.3.6.1.4.1.10159.1.2.3.1.6

panHwIpAddrTable

table obsolete
.1.3.6.1.4.1.10159.1.2.4 · 1 row entry · 2 columns
Uses the panasas variant from /opt/observium/mibs/panasas.
Command help
Walk panHwIpAddrTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PANASAS-HW-MIB-V1' -M '/opt/observium/mibs/panasas:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PANASAS-HW-MIB-V1::panHwIpAddrTable'
Table to map IP Addresses to Blades.
NOTE: This is table is obsoleted.
panHwIpAddrEntry row .1.3.6.1.4.1.10159.1.2.4.1
An entry in panHwIpAddrTable.
Indexes
Column Syntax OID
panHwIpAddrobsolete
Index into panHwIpAddrTable.
SNMPv2-SMIIpAddress
Type Constraints:
range: 4
.1.3.6.1.4.1.10159.1.2.4.1.1
Blade HW Serial Number (an index into panHwBladeTable).PANASAS-TC-MIBPanSerialNumber
Type Constraints:
range: 8..32
.1.3.6.1.4.1.10159.1.2.4.1.2
.1.3.6.1.4.1.10159.1.2.5.1 · 1 row entry · 4 columns
Uses the panasas variant from /opt/observium/mibs/panasas.
Command help
Walk panHwControllerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PANASAS-HW-MIB-V1' -M '/opt/observium/mibs/panasas:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PANASAS-HW-MIB-V1::panHwControllerTable'
The main controller table.
This table is extended by other tables that describe
controller resources like drives.
panHwControllerEntry row .1.3.6.1.4.1.10159.1.2.5.1.1
Controller Hardware Information
Column Syntax OID
panHwControllerSNFactory assigned unique Serial Number of a controller and an
index into panHwControllerTable.
PANASAS-TC-MIBPanSerialNumber
Type Constraints:
range: 8..32
.1.3.6.1.4.1.10159.1.2.5.1.1.1
panHwControllerNameName assigned to the controller.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.5.1.1.2
panHwControllerFirmwareRevController's firmware revision.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.5.1.1.3
panHwControllerNvsramRevController's nvsram revision.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.5.1.1.4
.1.3.6.1.4.1.10159.1.2.5.2 · 1 row entry · 2 columns
Uses the panasas variant from /opt/observium/mibs/panasas.
Command help
Walk panHwControllerOsdTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PANASAS-HW-MIB-V1' -M '/opt/observium/mibs/panasas:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PANASAS-HW-MIB-V1::panHwControllerOsdTable'
Extends panHwControllerTable..
Table listing the OSDs controlled by the controller.
panHwControllerOsdEntry row .1.3.6.1.4.1.10159.1.2.5.2.1
An entry in panHwControllerOsdTable.
Column Syntax OID
panHwControllerOsdLunNumThe lun number managed by this OSD.
This is an index into this table.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.10159.1.2.5.2.1.1
panHwControllerOsdNameOSD's name.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.5.2.1.2
.1.3.6.1.4.1.10159.1.2.5.3 · 1 row entry · 2 columns
Uses the panasas variant from /opt/observium/mibs/panasas.
Command help
Walk panHwControllerStorageServerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PANASAS-HW-MIB-V1' -M '/opt/observium/mibs/panasas:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PANASAS-HW-MIB-V1::panHwControllerStorageServerTable'
Extends panHwControllerTable..
Table listing the Storage Servers associated with the controller.
panHwControllerStorageServerEntry row .1.3.6.1.4.1.10159.1.2.5.3.1
An entry in panHwControllerStorageServerTable.
Column Syntax OID
panHwControllerStorageServerSNThis is the StorageServer's hardware serial number,
which is the same as panHwBladeHwSN of the panHwBladeTable.
This is an index into this table.
PANASAS-TC-MIBPanSerialNumber
Type Constraints:
range: 8..32
.1.3.6.1.4.1.10159.1.2.5.3.1.1
panHwControllerStorageServerNameStorage server's name.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.5.3.1.2
.1.3.6.1.4.1.10159.1.2.5.4 · 1 row entry · 12 columns
Uses the panasas variant from /opt/observium/mibs/panasas.
Command help
Walk panHwControllerDriveTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PANASAS-HW-MIB-V1' -M '/opt/observium/mibs/panasas:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PANASAS-HW-MIB-V1::panHwControllerDriveTable'
Extends panHwControllerTable..
Table listing the drives controlled by the controller.
panHwControllerDriveEntry row .1.3.6.1.4.1.10159.1.2.5.4.1
An entry in panHwShelfSlotTable.
Column Syntax OID
panHwControllerDriveDrawerThe location of a drive is uniquely identified by its drawer number,
tray number and slot number.
This is the drawer number.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.10159.1.2.5.4.1.1
panHwControllerDriveTrayThe location of a drive is uniquely identified by its drawer number,
tray number and slot number.
This is the tray number.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.10159.1.2.5.4.1.2
panHwControllerDriveSlotThe location of a drive is uniquely identified by its drawer number,
tray number and slot number.
This is the slot number.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.10159.1.2.5.4.1.3
panHwControllerDriveSNSerial number of the drive.PANASAS-TC-MIBPanSerialNumber
Type Constraints:
range: 8..32
.1.3.6.1.4.1.10159.1.2.5.4.1.4
panHwControllerDriveVendorVendor name of the drive.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.5.4.1.5
panHwControllerDriveModelModel number of the drive.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.5.4.1.6
panHwControllerDriveFirmwareRevFirmware revision of the drive.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.5.4.1.7
panHwControllerDriveTypeType of drive. Possible values are
SSD, SATA, SAS, FC and Unknown.
RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.5.4.1.8
panHwControllerDriveTotalCapacityToal capacity in GB of drive.RFC1213-MIBDisplayString.1.3.6.1.4.1.10159.1.2.5.4.1.9
panHwControllerDriveFormattedIndicates if drives is formatted or not.
A value of panTrue indicates the drive is formatted.
.1.3.6.1.4.1.10159.1.2.5.4.1.10
panHwControllerDriveFailedIndicates if drive had failed.
A value of panTrue indicates failure.
.1.3.6.1.4.1.10159.1.2.5.4.1.11
panHwControllerDriveHotSpareIndicates if drive is a hot spare.
A value of panTrue means the drive is a hot spare .
.1.3.6.1.4.1.10159.1.2.5.4.1.12