OPTIX-SDH-EOW-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
7
Rows
7
Columns
24
.1.3.6.1.4.1.2011.2.25.4.10.50.1.1 · 1 row entry · 6 columns
Uses the huawei variant from /opt/observium/mibs/huawei.
Command help
Walk optixEowTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'OPTIX-SDH-EOW-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'OPTIX-SDH-EOW-MIB::optixEowTable'
This table describes the basicorderwire configurations.
optixEowEntry row .1.3.6.1.4.1.2011.2.25.4.10.50.1.1.1
Thisentry describes the basic orderwire configurations.
Column Syntax OID
optixEowTelLenThis object indicates the length (range 3 to 8) of the orderwire call numberSNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2011.2.25.4.10.50.1.1.1.1
optixEowReqTimeThis object indicates the call waiting time. Value range: 1 to 9.SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2011.2.25.4.10.50.1.1.1.2
optixEowE1orE2ByteThis parameter indicates the E1/E2 bytes selective receiving of orderwires. 0: E1 1: E2Enumerationr/w
Enumerated Values:
0e1
1e2
.1.3.6.1.4.1.2011.2.25.4.10.50.1.1.1.3
optixEowMeetNumThis object indicates the meet number (range 100 to 99999999) of which the value depends on tellenSNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2011.2.25.4.10.50.1.1.1.4
optixEowGroupTelNumThis object indicates the group telphone number. This parameter takes a fixed value of 888.SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2011.2.25.4.10.50.1.1.1.5
optixEowSubnetLenThis object indicates the subnet ID length. Value range: 1 or 2.SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2011.2.25.4.10.50.1.1.1.6
.1.3.6.1.4.1.2011.2.25.4.10.50.1.2 · 1 row entry · 2 columns
Uses the huawei variant from /opt/observium/mibs/huawei.
Command help
Walk optixEowTelTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'OPTIX-SDH-EOW-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'OPTIX-SDH-EOW-MIB::optixEowTelTable'
This table describes the basiccall configurations.
optixEowTelEntry row .1.3.6.1.4.1.2011.2.25.4.10.50.1.2.1
Thisentry describes the basic call configurations.
Column Syntax OID
optixEowTelNumThis object indicates the numbersequence. Value range: 1 to N. RTN equipment supports only 1.SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2011.2.25.4.10.50.1.2.1.1
optixEowTelNumberThis object indicates the phone number. Value range: 100 to 9999999.SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2011.2.25.4.10.50.1.2.1.2
.1.3.6.1.4.1.2011.2.25.4.10.50.1.3 · 1 row entry · 1 columns
Uses the huawei variant from /opt/observium/mibs/huawei.
Command help
Walk optixEowSubnetTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'OPTIX-SDH-EOW-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'OPTIX-SDH-EOW-MIB::optixEowSubnetTable'
This table describes the basicsubnet configurations.
optixEowSubnetEntry row .1.3.6.1.4.1.2011.2.25.4.10.50.1.3.1
Thisentry describes the basic subnet configurations.
Column Syntax OID
optixEowSubnetIdThis object indicates the subnet ID, which must be a hexademical number that ranges from 0x01 to 0x99, and consists of only digits 0 to 9 but no characters A to FSNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2011.2.25.4.10.50.1.3.1.1
.1.3.6.1.4.1.2011.2.25.4.10.50.1.4 · 1 row entry · 3 columns
Uses the huawei variant from /opt/observium/mibs/huawei.
Command help
Walk optixEowPortUsedTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'OPTIX-SDH-EOW-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'OPTIX-SDH-EOW-MIB::optixEowPortUsedTable'
This table describes the basic configurations ofport usage.
optixEowPortUsedEntry row .1.3.6.1.4.1.2011.2.25.4.10.50.1.4.1
Thisentry describes the basic configurations of port usage.
Column Syntax OID
optixEowIuBidThis object indicates the slot ID and board ID of the common service management line boardSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2011.2.25.4.10.50.1.4.1.1
optixEowLineUsedThis object indicates the optical port usage information. 0: unused, 1: usedEnumerationr/w
Enumerated Values:
0unused
1used
.1.3.6.1.4.1.2011.2.25.4.10.50.1.4.1.2
optixEowMeetLineUsedThis object indicates the meet optical port usage information. 0: unused, 1: usedEnumerationr/w
Enumerated Values:
0unused
1used
.1.3.6.1.4.1.2011.2.25.4.10.50.1.4.1.3
.1.3.6.1.4.1.2011.2.25.4.10.50.1.5 · 1 row entry · 4 columns
Uses the huawei variant from /opt/observium/mibs/huawei.
Command help
Walk optixDataPortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'OPTIX-SDH-EOW-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'OPTIX-SDH-EOW-MIB::optixDataPortTable'
Thistable describes the basicbroadcast data port configurations.
optixDataPortEntry row .1.3.6.1.4.1.2011.2.25.4.10.50.1.5.1
Thisentry describes the basic broadcast data port configurations.
Column Syntax OID
optixDataPortOhSlotThis object indicates the overhead byte. Serial1 to Serial4. Value range: 1 to 4.SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2011.2.25.4.10.50.1.5.1.1
optixDataPortSlavePortIdThis object indicates the slave port number of broadcast data. The value is determined by the slot ID and port ID of the line board.SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2011.2.25.4.10.50.1.5.1.2
optixDataPortMainPortIdThis object indicates themaster port number of broadcast data. The value is determined by the slot ID and port ID of the line board.SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2011.2.25.4.10.50.1.5.1.3
optixDataPortSlavePortNumThis object indicates the number of slave ports of broadcast data.SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2011.2.25.4.10.50.1.5.1.4
.1.3.6.1.4.1.2011.2.25.4.10.50.1.6 · 1 row entry · 3 columns
Uses the huawei variant from /opt/observium/mibs/huawei.
Command help
Walk optixF1PortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'OPTIX-SDH-EOW-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'OPTIX-SDH-EOW-MIB::optixF1PortTable'
This table describes the basicF1 portconfigurations.
optixF1PortEntry row .1.3.6.1.4.1.2011.2.25.4.10.50.1.6.1
This entry describes the basic F1 port configurations.
Column Syntax OID
optixF1PortIdThis object indicates the F1 port number that ranges 1 to 7SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2011.2.25.4.10.50.1.6.1.1
optixF1PortInputPortThis object indicates the upstream port of the F1 port. The value is determined by the slot ID and port ID of the line board. This parameter can also take the value of 0xff00.SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2011.2.25.4.10.50.1.6.1.2
optixF1PortOutputPortThis object indicates the downstream port of the F1 port. The value is determined by the slot ID and port ID of the line board.SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2011.2.25.4.10.50.1.6.1.3
.1.3.6.1.4.1.2011.2.25.4.10.50.1.7 · 1 row entry · 5 columns
Uses the huawei variant from /opt/observium/mibs/huawei.
Command help
Walk optixDataPortEXTTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'OPTIX-SDH-EOW-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'OPTIX-SDH-EOW-MIB::optixDataPortEXTTable'
Thistable describes the basicbroadcast data port configurations.
optixDataPortEXTEntry row .1.3.6.1.4.1.2011.2.25.4.10.50.1.7.1
Thisentry describes the basic broadcast data port configurations.
Column Syntax OID
optixEXTDataPortOhSlotThis object indicates the overhead byte. Serial1 to Serial4. Value range: 1 to 4.SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2011.2.25.4.10.50.1.7.1.1
optixEXTDataPortMainPortIdThis object indicates themaster port number of broadcast data. The value is determined by the slot ID and port ID of the line board.SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2011.2.25.4.10.50.1.7.1.2
optixEXTDataPortSlavePortNumThis object indicates the number of slave ports of broadcast data. Value range: 1 to N. RTN equipment supports only 1.SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.2011.2.25.4.10.50.1.7.1.3
optixEXTDataPortSlavePortIdThis object indicates the slave port number of broadcast data. The value is determined by the slot ID and port ID of the line board.OctetStringr/w
Constraints:
range: 0-128
.1.3.6.1.4.1.2011.2.25.4.10.50.1.7.1.4
optixEXTDataPortRowStatusThis object indicates the RowStatus of broadcast data.SNMPv2-TCRowStatusr/w
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.2011.2.25.4.10.50.1.7.1.255