almLos
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.1 | Trap of Alarm: Loss of signal |
almRsCrosstr
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.10 | Regenerator section performance over threshold |
almLti
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.100 | The LTI is an alarm indicating the loss of synchronization source |
almSynBad
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.101 | The SYN_BAD is a synchronization source degrade alarm |
almSyncCLos
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.111 | This alarm occurs when the clock source of a service board is lost in the priority table |
almFanFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.115 | Trap of Alarm: Fan failure |
almBdStatus
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.119 | Trap of Alarm: board offline except main control board |
almB1Exc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12 | The B1_EXC is an alarm indicating that the number of regenerator section B1 bit errors in the signals received over the line crosses the threshold |
almWrgBdType
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.121 | Trap of Alarm: Wrong board type |
almDlagProtectFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12288 | Trap of Alarm: DLAG protection failed. |
almShelfIdConflict
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12302 | Trap of Alarm: Subrack ID conflict |
almSubrackIdMismatch
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12303 | The hardware subrack ID mismatches that saved in the NE software |
almShelfLoop
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12304 | Trap of Alarm: Subrack forming a loop |
almRelayAlarmCritical
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12305 | The RELAY_ALARM_CRITICAL is an alarm of critical alarm inputs |
almRelayAlarmMajor
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12306 | The RELAY_ALARM_MAJOR is an alarm of major alarm inputs |
almRelayAlarmMinor
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12307 | The RELAY_ALARM_MINOR is an alarm of minor alarm inputs |
almRelayAlarmIgnore
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12308 | The RELAY_ALARM_IGNORE is an alarm of warning alarm inputs |
almSingleFanFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12309 | Trap of Alarm: Fan fault |
almOtu1Lof
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12311 | Loss of OTUk frame |
almOtu1Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12312 | OTUk alarm indication signal |
almOtu1Lom
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12313 | Loss of OTUk multiframe |
almOtu1Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12314 | OTUk TTI mismatch |
almOtu1Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12315 | OTUk signal degraded alarm |
almOtu1Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12316 | OTUk backward defect indication |
almOtu2Lof
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12323 | Loss of OTUk frame |
almOtu2Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12324 | OTUk alarm indication signal |
almOtu2Lom
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12325 | Loss of OTUk multiframe |
almOtu2Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12326 | OTUk TTI mismatch |
almOtu2Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12327 | OTUk signal degraded alarm |
almOtu2Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12328 | OTUk backward defect indication |
almOtu3Lof
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12329 | Loss of OTUk frame |
almOtu3Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12330 | 12330 |
almOtu3Lom
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12331 | 12331 |
almOtu3Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12332 | 12332 |
almOtu3Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12333 | 12333 |
almOtu3Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12334 | 12334 |
almOdu1PmTim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12335 | ODU1 PM section TTI mismatch |
almOdu1PmDeg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12336 | ODUk PM signal degraded |
almOdu1PmBdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12337 | ODUk PM backward defect indication |
almOdu1PmLck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12338 | ODU1 PM signal locked |
almOdu1PmOci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12339 | ODUk PM open connection indication |
almOdu1PmAis
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12340 | ODUk PM alarm indication signal |
almOdu1Loflom
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12341 | Loss of ODUk frame and multiframe |
almOdu2PMTim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12349 | Trap of Alarm: ODU2 PM trace identifier mismatch |
almOdu2PMDeg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12350 | Trap of Alarm: ODU2 PM signal degrade alarm |
almOdu2PMBdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12351 | Trap of Alarm: ODU2 PM backward defect indication |
almOdu2PMLck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12352 | Trap of Alarm: ODU2 PM locked defect |
almOdu2PMOci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12353 | Trap of Alarm: ODU2 PM open connection indication |
almOdu2PMAis
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12354 | Trap of Alarm: ODU2 PM alarm indication signal |
almOdu2Loflom
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12355 | Trap of Alarm: ODU2 PM loss of frame and multi-frame |
almOdu3PMTim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12356 | Trap of Alarm: ODU3 PM trace identifier mismatch |
almOdu3PMDeg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12357 | Trap of Alarm: ODU3 PM signal degrade alarm |
almOdu3PMBdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12358 | Trap of Alarm: ODU3 PM backward defect indication |
almOdu3PMLck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12359 | Trap of Alarm: ODU3 PM locked defect |
almOdu3PMOci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12360 | Trap of Alarm: ODU3 PM open connection indication |
almOdu3PMAis
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12361 | Trap of Alarm: ODU3 PM alarm indication signal |
almOdu3Loflom
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12362 | Trap of Alarm: ODU3 PM loss of frame and multi-frame |
almOdu1Tcm1Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12363 | ODUk TCMn TTI mismatch |
almOdu1Tcm2Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12364 | ODUk TCMn TTI mismatch |
almOdu1Tcm3Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12365 | ODUk TCMn TTI mismatch |
almOdu1Tcm4Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12366 | ODUk TCMn TTI mismatch |
almOdu1Tcm5Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12367 | ODUk TCMn TTI mismatch |
almOdu1Tcm6Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12368 | ODUk TCMn TTI mismatch |
almOdu1Tcm1Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12369 | ODUk TCMn signal degraded |
almOdu1Tcm2Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12370 | ODUk TCMn signal degraded |
almOdu1Tcm3Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12371 | ODUk TCMn signal degraded |
almOdu1Tcm4Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12372 | ODUk TCMn signal degraded |
almOdu1Tcm5Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12373 | ODUk TCMn signal degraded |
almOdu1Tcm6Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12374 | ODUk TCMn signal degraded |
almOdu1Tcm1Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12375 | ODUk TCMn backward defect indication |
almOdu1Tcm2Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12376 | ODUk TCMn backward defect indication |
almOdu1Tcm3Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12377 | ODUk TCMn backward defect indication |
almOdu1Tcm4Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12378 | ODUk TCMn backward defect indication |
almOdu1Tcm5Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12379 | ODUk TCMn backward defect indication |
almOdu1Tcm6Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12380 | ODUk TCMn backward defect indication |
almOdu1Tcm1Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12381 | ODUk TCMn alarm indication signal |
almOdu1Tcm2Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12382 | ODUk TCMn alarm indication signal |
almOdu1Tcm3Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12383 | ODUk TCMn alarm indication signal |
almOdu1Tcm4Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12384 | ODUk TCMn alarm indication signal |
almOdu1Tcm5Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12385 | ODUk TCMn alarm indication signal |
almOdu1Tcm6Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12386 | ODUk TCMn alarm indication signal |
almOdu1Tcm1Oci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12387 | ODUk TCMn open connection indication |
almOdu1Tcm2Oci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12388 | ODUk TCMn open connection indication |
almOdu1Tcm3Oci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12389 | ODUk TCMn open connection indication |
almOdu1Tcm4Oci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12390 | ODUk TCMn open connection indication |
almOdu1Tcm5Oci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12391 | ODUk TCMn open connection indication |
almOdu1Tcm6Oci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12392 | ODUk TCMn open connection indication |
almOdu1Tcm1Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12393 | ODUk TCMn signal locked |
almOdu1Tcm2Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12394 | ODUk TCMn signal locked |
almOdu1Tcm3Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12395 | ODUk TCMn signal locked |
almOdu1Tcm4Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12396 | ODUk TCMn signal locked |
almOdu1Tcm5Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12397 | ODUk TCMn signal locked |
almOdu1Tcm6Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12398 | ODUk TCMn signal locked |
almOdu1Tcm1Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12399 | Loss of ODUk TCMn serial connection |
almOdu1Tcm2Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12400 | Loss of ODUk TCMn serial connection |
almOdu1Tcm3Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12401 | Loss of ODUk TCMn serial connection |
almOdu1Tcm4Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12402 | Loss of ODUk TCMn serial connection |
almOdu1Tcm5Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12403 | Loss of ODUk TCMn serial connection |
almOdu1Tcm6Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12404 | Loss of ODUk TCMn serial connection |
almOdu2Tcm1Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12447 | ODUk TCMn TTI mismatch |
almOdu2Tcm2Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12448 | ODUk TCMn TTI mismatch |
almOdu2Tcm3Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12449 | ODUk TCMn TTI mismatch |
almOdu2Tcm4Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12450 | ODUk TCMn TTI mismatch |
almOdu2Tcm5Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12451 | ODUk TCMn TTI mismatch |
almOdu2Tcm6Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12452 | ODUk TCMn TTI mismatch |
almOdu2Tcm1Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12453 | ODUk TCMn signal degraded |
almOdu2Tcm2Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12454 | ODUk TCMn signal degraded |
almOdu2Tcm3Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12455 | ODUk TCMn signal degraded |
almOdu2Tcm4Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12456 | ODUk TCMn signal degraded |
almOdu2Tcm5Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12457 | ODUk TCMn signal degraded |
almOdu2Tcm6Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12458 | ODUk TCMn signal degraded |
almOdu2Tcm1Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12459 | ODUk TCMn backward defect indication |
almOdu2Tcm2Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12460 | ODUk TCMn backward defect indication |
almOdu2Tcm3Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12461 | ODUk TCMn backward defect indication |
almOdu2Tcm4Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12462 | ODUk TCMn backward defect indication |
almOdu2Tcm5Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12463 | ODUk TCMn backward defect indication |
almOdu2Tcm6Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12464 | ODUk TCMn backward defect indication |
almOdu2Tcm1Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12465 | ODUk TCMn alarm indication signal |
almOdu2Tcm2Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12466 | ODUk TCMn alarm indication signal |
almOdu2Tcm3Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12467 | ODUk TCMn alarm indication signal |
almOdu2Tcm4Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12468 | ODUk TCMn alarm indication signal |
almOdu2Tcm5Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12469 | ODUk TCMn alarm indication signal |
almOdu2Tcm6Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12470 | ODUk TCMn alarm indication signal |
almOdu2Tcm1Oci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12471 | ODUk TCMn open connection indication |
almOdu2Tcm2Oci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12472 | ODUk TCMn open connection indication |
almOdu2Tcm3Oci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12473 | ODUk TCMn open connection indication |
almOdu2Tcm4Oci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12474 | ODUk TCMn open connection indication |
almOdu2Tcm5Oci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12475 | ODUk TCMn open connection indication |
almOdu2Tcm6Oci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12476 | ODUk TCMn open connection indication |
almOdu2Tcm1Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12477 | ODUk TCMn signal locked |
almOdu2Tcm2Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12478 | ODUk TCMn signal locked |
almOdu2Tcm3Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12479 | ODUk TCMn signal locked |
almOdu2Tcm4Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12480 | ODUk TCMn signal locked |
almOdu2Tcm5Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12481 | ODUk TCMn signal locked |
almOdu2Tcm6Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12482 | ODUk TCMn signal locked |
almOdu2Tcm1Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12483 | Loss of ODUk TCMn serial connection |
almOdu2Tcm2Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12484 | Loss of ODUk TCMn serial connection |
almOdu2Tcm3Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12485 | Loss of ODUk TCMn serial connection |
almOdu2Tcm4Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12486 | Loss of ODUk TCMn serial connection |
almOdu2Tcm5Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12487 | Loss of ODUk TCMn serial connection |
almOdu2Tcm6Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12488 | Loss of ODUk TCMn serial connection |
almOdu3Tcm1Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12489 | ODU3_TCM1_TIM |
almOdu3Tcm2Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12490 | ODU3_TCM2_TIM |
almOdu3Tcm3Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12491 | ODU3_TCM3_TIM |
almOdu3Tcm4Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12492 | ODU3_TCM4_TIM |
almOdu3Tcm5Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12493 | ODU3_TCM5_TIM |
almOdu3Tcm6Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12494 | ODU3_TCM6_TIM |
almOdu3Tcm1Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12495 | ODU3_TCM1_DEG |
almOdu3Tcm2Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12496 | ODU3_TCM2_DEG |
almOdu3Tcm3Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12497 | ODU3_TCM3_DEG |
almOdu3Tcm4Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12498 | ODU3_TCM4_DEG |
almOdu3Tcm5Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12499 | ODU3_TCM5_DEG |
almPwrFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.125 | Trap of Alarm: Power failure |
almOdu3Tcm6Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12500 | ODU3_TCM6_DEG |
almOdu3Tcm1Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12501 | ODU3_TCM1_BDI |
almOdu3Tcm2Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12502 | ODU3_TCM2_BDI |
almOdu3Tcm3Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12503 | ODU3_TCM3_BDI |
almOdu3Tcm4Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12504 | ODU3_TCM4_BDI |
almOdu3Tcm5Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12505 | ODU3_TCM5_BDI |
almOdu3Tcm6Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12506 | ODU3_TCM6_BDI |
almOdu3Tcm1Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12507 | ODU3_TCM1_AIS |
almOdu3Tcm2Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12508 | ODU3_TCM2_AIS |
almOdu3Tcm3Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12509 | ODU3_TCM3_AIS |
almOdu3Tcm4Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12510 | ODU3_TCM4_AIS |
almOdu3Tcm5Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12511 | ODU3_TCM5_AIS |
almOdu3Tcm6Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12512 | ODU3_TCM6_AIS |
almOdu3Tcm1Oci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12513 | ODU3_TCM1_OCI |
almOdu3Tcm2Oci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12514 | ODU3_TCM2_OCI |
almOdu3Tcm3Oci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12515 | ODU3_TCM3_OCI |
almOdu3Tcm4Oci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12516 | ODU3_TCM4_OCI |
almOdu3Tcm5Oci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12517 | ODU3_TCM5_OCI |
almOdu3Tcm6Oci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12518 | ODU3_TCM6_OCI |
almOdu3Tcm1Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12519 | ODU3_TCM1_LCK |
almOdu3Tcm2Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12520 | ODU3_TCM2_LCK |
almOdu3Tcm3Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12521 | ODU3_TCM3_LCK |
almOdu3Tcm4Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12522 | ODU3_TCM4_LCK |
almOdu3Tcm5Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12523 | ODU3_TCM5_LCK |
almOdu3Tcm6Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12524 | ODU3_TCM6_LCK |
almOdu3Tcm1Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12525 | ODU3_TCM1_LTC |
almOdu3Tcm2Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12526 | ODU3_TCM2_LTC |
almOdu3Tcm3Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12527 | ODU3_TCM3_LTC |
almOdu3Tcm4Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12528 | ODU3_TCM4_LTC |
almOdu3Tcm5Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12529 | ODU3_TCM5_LTC |
almOdu3Tcm6Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12530 | ODU3_TCM6_LTC |
almOpu1Plm
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12531 | OPUk payload mismatch |
almOpu2Plm
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12533 | Trap of Alarm: OPU2 payload label mismatch |
almOpu2Msim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12534 | Trap of Alarm: OPU2 multiplex structure identifier mismatch |
almOpu3Plm
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12535 | Trap of Alarm: OPU3 payload label mismatch |
almOpu3Msim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12536 | Trap of Alarm: OPU3 multiplex structure identifier mismatch |
almOlpPs
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12537 | Optical line protection switching |
almIntraOtuPs
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12539 | Intra-OTU 1+1 protection switching |
almClientPortPs
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12540 | Trap of Alarm: Client-side 1+1 optical channel protection switching |
almOduSncpPs
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12541 | ODU SNCP protection switching |
almRemoteFault
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12544 | Trap of Alarm: Remote fault |
almLocalFault
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12545 | Trap of Alarm: Local fault |
almHardErr
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12580 | Trap of Alarm: Hardware error |
almElabelLost
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12581 | Trap of Alarm: No e-label. |
almLptActive
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12582 | Trap of Alarm: LPT switching occurred. |
almInsertionLossHigh
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12584 | Trap of Alarm: Excessive insertion loss between the TDC and RDC optical ports.The insertion loss between TDC and RDC does not match the gain. |
almModuleAdjustFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12585 | Trap of Alarm: The optical module adjusting failed. |
almsyslogcommfail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12586 | Trap of Alarm: Communication failure between NE and syslog server |
almClientPortNotStart
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12595 | Trap of Alarm: The alarm raises when the client-side 1+1 optical channel protection cannot start |
almOpaFailIndi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12596 | Automatic adjustment of power during optical cross-connection failed |
almModulefileUpdateFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12606 | Trap of Alarm: The optical module program upgrade failed. |
almOtsTim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12615 | Trap of Alarm: OTS trace identifier mismatch. |
almOtsLos
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12616 | Trap of Alarm: OTS loss of signal. |
almOtsLosP
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12617 | Trap of Alarm: OTS loss of signal - Payload. |
almOtsLosO
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12618 | Trap of Alarm: OTS loss of signal - Overhead. |
almOtsBdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12619 | Trap of Alarm: OTS backward defect indication. |
almOtsBdiP
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12620 | Trap of Alarm: OTS backward defect indication - Payload. |
almOtsBdiO
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12621 | Trap of Alarm: OTS backward defect indication - Overhead. |
almOosLost
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12622 | Trap of Alarm: Loss of OTM overhead signal. |
almOmsLosP
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12623 | Trap of Alarm: OMS loss of signal - Payload. |
almOmsSsf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12624 | Trap of Alarm: Server signal fail at OMS layer. |
almOmsSsfP
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12625 | Trap of Alarm: Server signal fail (payload) at OMS layer. |
almOmsSsfO
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12626 | Trap of Alarm: Server signal fail (overhead) at OMS layer. |
almOmsFdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12627 | Trap of Alarm: OMS forward defect indication. |
almOmsFdiP
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12628 | Trap of Alarm: OMS forward defect indication - Payload. |
almOmsFdiO
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12629 | Trap of Alarm: OMS forward defect indication - Overhead. |
almOmsBdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12630 | Trap of Alarm: OMS backward defect indication. |
almOmsBdiP
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12631 | Trap of Alarm: OMS backward defect indication - Payload. |
almOmsBdiO
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12632 | Trap of Alarm: OMS backward defect indication - Overhead. |
almOchLosP
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12633 | 12633 |
almOchOci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12634 | This alarm is generated when the downstream interrupt site receives the OCI signals inserted after proactive signal interrupt occurs in optical cross-connections |
almOchSsf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12635 | This alarm is generated when both OCH_SSF-P and OCH_SSF-O are generated |
almOchSsfP
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12636 | This alarm is generated when the load signals at the OMS layer are lost or the OMS layer receives FDI-P signals from the OCh layer in the upstream |
almOchSsfO
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12637 | This alarm is generated when the overhead signals at the OMS layer are lost or the OMS layer receives FDI-O signals from the OCh layer in the upstream |
almOchFdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12638 | This alarm is generated when both OCH_FDI-P and OCH_FDI-O are generated |
almOchFdiP
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12639 | This alarm is generated when the downstream receives the OCH_FDI-P overhead signals inserted by the OMS layer after the OMS layer detects load LOS |
almOchFdiO
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12640 | This alarm is generated when the downstream receives the OCH_FDI-O overhead signals inserted by the OMS layer after the OMS layer detects overhead LOS |
almOdukspPs
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12641 | 12641 |
almPrbsLss
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12643 | Trap of Alarm: Loss of PRBS(Pseudo-Random Binary Sequence) signal |
almDbRestoreFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12644 | Trap of Alarm: Database restoration failed. |
almOtu1Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12711 | OTU1 Server Signal Fail |
almOdu1PmSsf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12712 | ODU1 PM Server Signal Fail |
almOdu1Tcm1Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12713 | ODU1 TCM1 Server Signal Fail |
almOdu1Tcm2Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12714 | ODU1 TCM2 Server Signal Fail |
almOdu1Tcm3Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12715 | ODU1 TCM3 Server Signal Fail |
almOdu1Tcm4Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12716 | ODU1 TCM4 Server Signal Fail |
almOdu1Tcm5Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12717 | ODU1 TCM5 Server Signal Fail |
almOdu1Tcm6Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12718 | ODU1 TCM6 Server Signal Fail |
almOtu2Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12727 | OTU2 Server Signal Fail |
almOdu2PMSsf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12728 | Trap of Alarm: ODU2 PM Server Signal Fail |
almOdu2Tcm1Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12729 | ODU2 TCM1 Server Signal Fail |
almOdu2Tcm2Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12730 | ODU2 TCM2 Server Signal Fail |
almOdu2Tcm3Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12731 | ODU2 TCM3 Server Signal Fail |
almOdu2Tcm4Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12732 | ODU2 TCM4 Server Signal Fail |
almOdu2Tcm5Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12733 | ODU2 TCM5 Server Signal Fail |
almOdu2Tcm6Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12734 | ODU2 TCM6 Server Signal Fail |
almOtu3Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12735 | OTU3 Server Signal Fail |
almOdu3PMSsf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12736 | Trap of Alarm: ODU3 PM Server Signal Fail |
almOdu3Tcm1Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12737 | ODU3 TCM1 Server Signal Fail |
almOdu3Tcm2Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12738 | ODU3 TCM2 Server Signal Fail |
almOdu3Tcm3Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12739 | ODU3 TCM3 Server Signal Fail |
almOdu3Tcm4Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12740 | ODU3 TCM4 Server Signal Fail |
almOdu3Tcm5Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12741 | ODU3 TCM5 Server Signal Fail |
almOdu3Tcm6Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12742 | ODU3 TCM6 Server Signal Fail |
almDcmInsuff
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12745 | DCM_INSUFF |
almWavelenOver
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12771 | Trap of Alarm: The wavelength drift over the threshold. |
almQValueExc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12778 | The alarm is generated when the Q value is greater than the threshold |
almOnePumpWork
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12779 | Trap of Alarm: Only one pump card is working. |
almPumpLinkUllageHigh
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12780 | Trap of Alarm: Pump laser connection loss. |
almPumpOffline
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12784 | Trap of Alarm: The pump card is offline. |
almPatchPkgErr
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12790 | Trap of Alarm: Patch package file error |
almSyncDisable
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12792 | SYNC_DISABLE |
almMacFcsExc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12794 | Trap of Alarm: Bit error threshold-crossing detected at MAC layer. |
almMacFcsSd
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12795 | Trap of Alarm: Degrade threshold-crossing detected at MAC layer. |
almPumpMisMatch
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12840 | Trap of Alarm: The type of pump card does not match that of the board. |
almMutTlos
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12842 | Trap of Alarm: Loss of transmitted optical power. |
almOscLos
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12843 | OSC_LOS |
almTsCfgMismatch
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12856 | Trap of Alarm: Timeslot configuration mismatch. |
almPatchChgSccNotMatch
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12872 | Trap of Alarm: Patch inconsistency after the SCC board is replaced |
almApdTemHigh
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12878 | Trap of Alarm: APD temperature over upper threshold. |
almApdTemLow
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12879 | Trap of Alarm: APD temperature below lower threshold. |
almApdCoolAlm
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12880 | Trap of Alarm: APD cooling current over threshold. |
almStormCurQuenumOver
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12884 | Trap of Alarm: Alarm Storm |
almSsmQlFailed
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12914 | It must be able to configure a minimum SSM-QL related to the special port with SyncE timing input |
almSsmLos
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12917 | If no valid SSM is received during 5 seconds, a Loss_Of_SSM defect is detected |
almLanloc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12926 | Trap of Alarm: Ethernet communication failure. The alarm occurs when the external Ethernet communication and the network port fail |
almNullSend
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12929 | Trap of Alarm: NULL sending enable |
almLSync
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12956 | Loss of codeword synchronization at coding layer in incoming signal so as to stop receiving data |
almTimeNoTraceMode
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12963 | Precision clock is now working in freerun mode |
almTimeLos
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12964 | The timing source severity level is lost |
almLaserHazardWarning
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12969 | Trap of Alarm: Warning indication of the laser hazard
level. |
almExtTimeLoc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12972 | The EXT_TIME_LOC is an alarm indicating that the board detects no clock signal from the external clock source but the external clock port is enabled |
almShelfTypeMismatch
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12973 | Trap of Alarm: Subrack type mismatch |
almOaHighGain
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.12995 | Trap of Alarm: OA gain is higher than standard level. |
almArpMacMismatch
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13008 | Trap of Alarm: The mac of static arp is mismatched. |
almCpcNodeIdErr
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13044 | During the startup, when the node ID in the system parameter area is null or is different from the node ID saved in the database (if such a node ID exists in the database), the ASON software cannot be normally enabled and the alarm is reported |
almPasswordneedchange
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13047 | Trap of Alarm: The default user's default password must be changed to reduce risks |
almComexteccfull
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13049 | Trap of Alarm: Number of TCP connections between NEs running the automatically extended ECC protocol exceeding the system limit |
almWavedataMis
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13051 | Trap of Alarm: WAVEDATA_MIS |
almLockpowMis
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13052 | Trap of Alarm: Mismatch of lock-power attribute. |
almVoadataMis
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13053 | Trap of Alarm: Mismatch of attenuation attribute. |
almGaindataMis
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13054 | Trap of Alarm: Mismatch of gain attribute. |
almOdu0PmTim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13055 | ODU0 PM section TTI mismatch |
almOdu0PmDeg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13056 | odu0 PM signal degraded |
almOdu0PmBdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13057 | odu0 PM backward defect indication |
almOdu0PmLck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13058 | ODU0 PM signal locked |
almOdu0PmOci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13059 | ODUk PM open connection indication |
almOdu0PmAis
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13060 | ODUk PM alarm indication signal |
almOdu0Loflom
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13061 | Loss of ODUk frame and multiframe |
almOdu0PmSsf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13062 | The ODU0 PM layer signal failure alarm |
almOpu1Msim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13063 | OPU1 multiplex structure indicator mismatch |
almOpu0Plm
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13066 | OPU0 payload mismatch |
almServiceTypeExceedLicense
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13070 | The alarm indicates that the type of configured services exceeds the license limit |
almServiceCapacityExceedLicense
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13071 | The alarm indicates that the capacity of configured services exceeds the license limit |
almShelfAreaPowerOver
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13079 | This alarm is generated when the total power consumption of the boards of each partition of the subrack is higher or equal to the power consumption threshold for each partition |
almOpu0Csf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13082 | Client-side signals fail |
almOpu1Csf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13083 | Client-side signals fail |
almCpuBusy
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13090 | Trap of Alarm: CPU BUSY. |
almDcnsizeOver
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13110 | Trap of Alarm: number of NE in a DCN subnet exceeds the setting threshold |
almDcnLinkOver
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13111 | Trap of Alarm: DCNLINK_OVER. |
almMemOver
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13112 | This alarm indicates that the value of memory usage is too high,and it will report when the value of memory usage exceed the thresholds. |
almntpsyncfail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13125 | Trap of Alarm: NTP synchronization failure |
almSpanLossHigh
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13132 | Trap of Alarm: Span loss too high. |
almAlcWaitAdjust
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13133 | Trap of Alarm: ALC adjustment is pending for operation. |
almAlcAdjustFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13134 | Trap of Alarm: ALC adjustment fails. |
almOdukspStaIndi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13136 | Indicates the state of the ODUk SPRing protection group |
almOlpStaIndi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13137 | Indicates the state of the optical line protection group |
almClientPortStaIndi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13139 | Trap of Alarm: Client-side 1+1 optical channel protection status indication |
almIntraOtuStaIndi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13140 | Indicates the state of the intra-OTU 1+1 optical channel protection group |
almOduSncpStaIndi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13142 | Indicates the state of the ODU SNCP protection group |
almLcsFileNotExist
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13144 | The system is under license control but a license file is not loaded onto the system |
almLcsExpired
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13145 | The license has expired and the keepalive period of 60 days has also elapsed |
almLcsDaysOfGrace
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13146 | The license has expired and is within the keepalive period of 60 days |
almOdcDoorOpen
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13154 | The cabinet door is open |
almSecradiusfail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13169 | Trap of Alarm: Illegal RADIUS login |
almFeatureWithoutLicense
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13170 | A license-controlled feature is used but a license for the feature is not installed |
almOscDeg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13185 | Signal degraded alarm |
almOscBdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13186 | Backward defect indication |
almPtpTimestampAbn
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13188 | When the PTP (IEEE 1588v2) time stamp freezes, this alarm is reported |
almSwdlbdexclude
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13190 | Trap of Alarm:Boards excluded from the software package upgrade |
almPtpSourceSwitch
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13194 | When the ID of the Grandmaster source traced by the NE or the tracing port changes, this alarm is reported to remind the user of switchover of the IEEE 1588v2 tracing source |
almClkLockFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13195 | When the frequency of an NE is synchronized from the upstream,the frequency lock status is locking |
almTimeLockFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13196 | When the time of an NE is synchronized from the upstream,the time lock status is locking |
almWaveAddAbn
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13197 | Trap of Alarm: The actually accessed wavelengths on each optical interface can be obtained through the spectrum analysis module of the detect board.The wavelengths are then compared with the scanned wavelengths obtained during the defining.If there is a
wavelength that is not accessed,a wavelength drop alm is reported. |
almWaveDropAbn
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13198 | Trap of Alarm: The actually accessed wavelengths on each optical interface can be obtained through the spectrum analysis module of the detect board.The wavelengths are then compared with the scanned wavelengths obtained during the defining. If a new wavelength is detected,a wavelength add alm is reported. |
almApeAdjustPend
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13199 | Trap of Alarm: APE adjustment is pending for operation. |
almApeAdjustFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13200 | Trap of Alarm: APE adjustment fails. |
almotu4ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13201 | Trap of Alarm: OTU4 Server Signal Fail |
almotu4ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13202 | Trap of Alarm: OTU4 alarm indication signal |
almotu4lof
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13203 | Trap of Alarm: Loss of OTU4 frame |
almotu4lom
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13204 | Trap of Alarm: Loss of OTU4 multiframe |
almotu4Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13205 | Trap of Alarm: OTU4 trace identifier mismatch |
almotu4Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13206 | Trap of Alarm: OTU4 signal degrade |
almotu4Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13207 | Trap of Alarm: OTU4 backward alarm indication |
almOdu4PMSsf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13208 | Trap of Alarm: ODU4 PM Server Signal Fail |
almOdu4Tcm1Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13209 | ODU4 TCM1 Server Signal Fail |
almOdu4Tcm2Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13210 | ODU4 TCM2 Server Signal Fail |
almOdu4Tcm3Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13211 | ODU4 TCM3 Server Signal Fail |
almOdu4Tcm4Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13212 | ODU4 TCM4 Server Signal Fail |
almOdu4Tcm5Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13213 | ODU4 TCM5 Server Signal Fail |
almOdu4Tcm6Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13214 | ODU4 TCM6 Server Signal Fail |
almOdu4PMAis
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13215 | Trap of Alarm: ODU4 PM alarm indication signal |
almOdu4Tcm1Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13216 | ODUk TCMn alarm indication signal |
almOdu4Tcm2Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13217 | ODUk TCMn alarm indication signal |
almOdu4Tcm3Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13218 | ODUk TCMn alarm indication signal |
almOdu4Tcm4Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13219 | ODUk TCMn alarm indication signal |
almOdu4Tcm5Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13220 | ODUk TCMn alarm indication signal |
almOdu4Tcm6Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13221 | ODUk TCMn alarm indication signal |
almOdu4PMOci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13222 | Trap of Alarm: ODU4 PM open connection indication |
almOdu4Tcm1Oci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13223 | ODUk TCMn open connection indication |
almOdu4Tcm2Oci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13224 | ODUk TCMn open connection indication |
almOdu4Tcm3Oci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13225 | ODUk TCMn open connection indication |
almOdu4Tcm4Oci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13226 | ODUk TCMn open connection indication |
almOdu4Tcm5Oci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13227 | ODUk TCMn open connection indication |
almOdu4Tcm6Oci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13228 | ODUk TCMn open connection indication |
almOdu4PMLck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13229 | Trap of Alarm: ODU4 PM locked defect |
almOdu4Tcm1Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13230 | ODUk TCMn signal locked |
almOdu4Tcm2Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13231 | ODUk TCMn signal locked |
almOdu4Tcm3Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13232 | ODUk TCMn signal locked |
almOdu4Tcm4Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13233 | ODUk TCMn signal locked |
almOdu4Tcm5Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13234 | ODUk TCMn signal locked |
almOdu4Tcm6Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13235 | ODUk TCMn signal locked |
almOdu4Tcm1Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13236 | Loss of ODUk TCMn serial connection |
almOdu4Tcm2Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13237 | Loss of ODUk TCMn serial connection |
almOdu4Tcm3Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13238 | Loss of ODUk TCMn serial connection |
almOdu4Tcm4Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13239 | Loss of ODUk TCMn serial connection |
almOdu4Tcm5Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13240 | Loss of ODUk TCMn serial connection |
almOdu4Tcm6Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13241 | Loss of ODUk TCMn serial connection |
almOdu4PMTim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13242 | Trap of Alarm: ODU4 PM trace identifier mismatch |
almOdu4Tcm1Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13243 | ODUk TCMn TTI mismatch |
almOdu4Tcm2Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13244 | ODUk TCMn TTI mismatch |
almOdu4Tcm3Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13245 | ODUk TCMn TTI mismatch |
almOdu4Tcm4Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13246 | ODUk TCMn TTI mismatch |
almOdu4Tcm5Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13247 | ODUk TCMn TTI mismatch |
almOdu4Tcm6Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13248 | ODUk TCMn TTI mismatch |
almOdu4PMDeg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13249 | Trap of Alarm: ODU4 PM signal degrade alarm |
almOdu4Tcm1Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13250 | ODUk TCMn signal degraded |
almOdu4Tcm2Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13251 | ODUk TCMn signal degraded |
almOdu4Tcm3Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13252 | ODUk TCMn signal degraded |
almOdu4Tcm4Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13253 | ODUk TCMn signal degraded |
almOdu4Tcm5Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13254 | ODUk TCMn signal degraded |
almOdu4Tcm6Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13255 | ODUk TCMn signal degraded |
almOdu4PMBdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13263 | Trap of Alarm: ODU4 PM backward defect indication |
almOdu4Tcm1Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13264 | ODUk TCMn backward defect indication |
almOdu4Tcm2Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13265 | ODUk TCMn backward defect indication |
almOdu4Tcm3Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13266 | ODUk TCMn backward defect indication |
almOdu4Tcm4Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13267 | ODUk TCMn backward defect indication |
almOdu4Tcm5Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13268 | ODUk TCMn backward defect indication |
almOdu4Tcm6Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13269 | ODUk TCMn backward defect indication |
almOpu4Plm
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13270 | Trap of Alarm: OPU4 payload label mismatch |
almOpu4Msim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13271 | Trap of Alarm: OPU4 multiplex structure identifier mismatch |
almEthMisconnect
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13272 | Trap of Alarm: LAN cable for the link between shelves misconnects. |
almSubrackCommPS
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13273 | Trap of Alarm: Alarm of protection switching of inter-subrack communication. Subrack link auto switch |
almodu4loflom
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13275 | Trap of Alarm: ODU4 frame and multiframes loss |
almSpanLossLow
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13280 | Trap of Alarm: Span loss too low. |
almOpu2Csf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13309 | Trap of Alarm: Client-side signals fail |
almOpuflexPlm
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13310 | OPUk payload mismatch |
almOduflexPmSsf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13311 | The ODUFlex PM layer signals fail |
almOduflexPmTim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13312 | ODUFlex PM section TTI mismatch |
almOduflexPmDeg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13313 | ODUFlex PM signal degraded |
almOduflexPmBdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13314 | ODUFlex PM backward defect indication |
almOduflexPmLck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13315 | ODUFlex PM signal locked |
almOduflexPmOci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13316 | ODUFlex PM open connection indication |
almOduflexPmAis
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13317 | ODUFlex PM alarm indication signal |
almOduflexLoflom
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13318 | Loss of ODUFlex frame and multiframe |
almOduflexPmExc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13319 | The number of BIP8 bit errors in the ODUFlex PM section exceeds the threshold |
almOdu0Tcm1Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13320 | Identifiers (API) in the input signals and the expected API |
almOdu0Tcm1Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13321 | ODU0 TCMk backward defect indication |
almOdu0Tcm1Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13322 | ODU0 TCMk alarm indication signal |
almOdu0Tcm1Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13323 | ODU0 TCMk signal locked |
almOdu0Tcm1Oci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13324 | ODU0 TCMk open connection indication |
almOdu0Tcm1Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13325 | Loss of ODUk TCMn serial connection |
almOdu0Tcm1Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13326 | ODU0 TCMk signal degraded |
almOdu0Tcm1Exc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13327 | The number of BIP8 bit errors in the ODU0 TCMk section exceeds the threshold |
almOdu0Tcm1Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13328 | The ODU0 TCMk layer signal failure alarm |
almOdu0Tcm2Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13329 | Identifiers (API) in the input signals and the expected API |
almOdu0Tcm2Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13330 | ODU0 TCM1 backward defect indication |
almOdu0Tcm2Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13331 | ODU0 TCM2 alarm indication signal |
almOdu0Tcm2Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13332 | ODU0 TCMk signal locked |
almOdu0Tcm2Oci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13333 | ODU0 TCMk open connection indication |
almOdu0Tcm2Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13334 | Loss of ODUk TCMn serial connection |
almOdu0Tcm2Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13335 | ODU0 TCMk signal degraded |
almOdu0Tcm2Exc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13336 | The number of BIP8 bit errors in the ODU0 TCMk section exceeds the threshold |
almOdu0Tcm2Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13337 | The ODU0 TCMk layer signal failure alarm |
almOdu0Tcm3Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13338 | Identifiers (API) in the input signals and the expected API |
almOdu0Tcm3Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13339 | ODU0 TCMk backward defect indication |
almOdu0Tcm3Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13340 | ODU0 TCMk alarm indication signal |
almOdu0Tcm3Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13341 | ODU0 TCMk signal locked |
almOdu0Tcm3Oci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13342 | ODU0 TCMk open connection indication |
almOdu0Tcm3Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13343 | Loss of ODUk TCMn serial connection |
almOdu0Tcm3Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13344 | ODU0 TCMk signal degraded |
almOdu0Tcm3Exc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13345 | The number of BIP8 bit errors in the ODU0 TCMk section exceeds the threshold |
almOdu0Tcm3Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13346 | The ODU0 TCMk layer signal failure alarm |
almOdu0Tcm4Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13347 | Identifiers (API) in the input signals and the expected API |
almOdu0Tcm4Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13348 | ODU0 TCMk backward defect indication |
almOdu0Tcm4Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13349 | ODU0 TCMk alarm indication signal |
almOdu0Tcm4Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13350 | ODU0 TCMk signal locked |
almOdu0Tcm4Oci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13351 | ODU0 TCMk open connection indication |
almOdu0Tcm4Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13352 | Loss of ODUk TCMn serial connection |
almOdu0Tcm4Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13353 | ODU0 TCMk signal degraded |
almOdu0Tcm4Exc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13354 | The number of BIP8 bit errors in the ODU0 TCMk section exceeds the threshold |
almOdu0Tcm4Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13355 | The ODU0 TCMk layer signal failure alarm |
almOdu0Tcm5Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13356 | Identifiers (API) in the input signals and the expected API |
almOdu0Tcm5Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13357 | ODU0 TCMk backward defect indication |
almOdu0Tcm5Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13358 | ODU0 TCMk alarm indication signal |
almOdu0Tcm5Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13359 | ODU0 TCMk signal locked |
almOdu0Tcm5Oci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13360 | ODU0 TCMk open connection indication |
almOdu0Tcm5Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13361 | Loss of ODUk TCMn serial connection |
almOdu0Tcm5Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13362 | ODU0 TCMk signal degraded |
almOdu0Tcm5Exc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13363 | The number of BIP8 bit errors in the ODU0 TCMk section exceeds the threshold |
almOdu0Tcm5Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13364 | The ODU0 TCMk layer signal failure alarm |
almOdu0Tcm6Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13365 | Identifiers (API) in the input signals and the expected API |
almOdu0Tcm6Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13366 | ODU0 TCMk backward defect indication |
almOdu0Tcm6Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13367 | ODU0 TCMk alarm indication signal |
almOdu0Tcm6Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13368 | ODU0 TCMk signal locked |
almOdu0Tcm6Oci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13369 | ODU0 TCMk open connection indication |
almOdu0Tcm6Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13370 | Loss of ODUk TCMn serial connection |
almOdu0Tcm6Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13371 | ODU0 TCMk signal degraded |
almOdu0Tcm6Exc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13372 | The number of BIP8 bit errors in the ODU0 TCMk section exceeds the threshold |
almOdu0Tcm6Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13373 | The ODU0 TCMk layer signal failure alarm |
almAlsActive
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13412 | Trap of Alarm: AlsActive |
almRlCriticalHi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13414 | Trap of Alarm: High return loss alarm - critical. |
almRlCriticalLow
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13415 | Trap of Alarm: Low return loss alarm - critical. |
almBdLedTest
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13419 | Trap of Alarm: Board LED Flash Test |
almRxPowerAbnormal
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13423 | The optical module demultiplexes one signal into multiple channels of optical signals and transmits them at the same time |
almOpuflexCsf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13434 | Client-side signals fail |
almOpu3Csf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13435 | Trap of Alarm: Client-side signals fail |
almOpu4Csf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13436 | Trap of Alarm: Client-side signals fail |
almEfiTypeMismatch
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13437 | Trap of Alarm: Mismatch between the EFI board type and subrack type. |
almModuleRateMismatch
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13443 | The module does not support the speed-up mode |
almFibertypeMis
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13483 | Trap of Alarm: Fiber type mismatch. |
almFopNr
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13487 | After transmitting an APS command request, the local end does not receive any RRs or APS command quests from the peer end within 1s |
almFopPr
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13488 | Information in the received APS frame and the type of APS protection configured at the local end are inconsistent |
almRmtDevPowerOff
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13489 | Trap of Alarm: Remote device power-off alarm. |
almDbmsDelete
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13502 | Trap of Alarm: NE database deletion |
almAlsTriggered
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13504 | Trap of Alarm: Automatic laser shutdown. |
almLaserCheckErr
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13506 | This alarm indicates that the current optical module has a write/read error |
almNeipConfusion
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13513 | Trap of Alarm: NE IP address conflict. |
almSslcertnoenc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13514 | Trap of Alarm: Certificate file of SSL is not encrypted |
almAseNotCalibrate
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13534 | Trap of Alarm: The alarm is generated when the amplified spontaneous emission (ASE) on the RAMAN board is not demarcated. |
almDerivedPwrError
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13541 | Trap of Alarm: Optical power exception alarm. |
almNoBdPower
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13542 | This alarm indicates that the board is not powered on |
almInnerCommunMiscon
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13543 | Trap of Alarm: Inner Communication Misconnect |
almSubnetRTConflict
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13545 | Trap of Alarm: When network route to NMS port conflict with other direct DCN OSPF network route, and the latter‘s mask is longer than the former‘s, it may cause PC communication problem. When there are more than one conflict routes, report the one has the longest mask. |
almPatchBdExclude
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13557 | Trap of Alarm: Exclusion of a patch package board |
almPatchBdMatchFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13558 | Trap of Alarm: Patch package matching failure |
almOduflexTcm4Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13565 | The ODUFLEX TCMk layer signal failure alarm |
almOduflexTcm4Exc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13566 | The number of BIP8 bit errors in the ODUFLEX TCMk section exceeds the threshold |
almOduflexTcm4Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13567 | Loss of ODUk TCMn serial connection |
almOduflexTcm4Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13568 | ODUFLEX TCMk signal degraded |
almOduflexTcm4Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13569 | ODUFLEX TCMk signal locked |
almOduflexTcm4Oci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13570 | ODUFLEX TCMk open connection indication |
almOduflexTcm4Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13571 | ODUFLEX TCMk backward defect indication |
almOduflexTcm4Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13572 | ODUFLEX TCMk alarm indication signal |
almOduflexTcm4Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13573 | Identifiers (API) in the input signals and the expected API |
almOduflexTcm5Exc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13574 | The number of BIP8 bit errors in the ODUFLEX TCMk section exceeds the threshold |
almOduflexTcm5Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13575 | The ODUFLEX TCMk layer signal failure alarm |
almOduflexTcm5Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13576 | ODUFLEX TCMk signal locked |
almOduflexTcm5Oci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13577 | ODUFLEX TCMk open connection indication |
almOduflexTcm5Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13578 | Loss of ODUk TCMn serial connection |
almOduflexTcm5Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13579 | ODUFLEX TCMk signal degraded |
almOduflexTcm5Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13580 | Identifiers (API) in the input signals and the expected API |
almOduflexTcm5Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13581 | ODUFLEX TCMk backward defect indication |
almOduflexTcm5Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13582 | ODUFLEX TCMk alarm indication signal |
almOduflexTcm6Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13583 | Identifiers (API) in the input signals and the expected API |
almOduflexTcm6Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13584 | ODUFLEX TCMk signal locked |
almOduflexTcm6Oci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13585 | ODUFLEX TCMk open connection indication |
almOduflexTcm6Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13586 | ODUFLEX TCMk backward defect indication |
almOduflexTcm6Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13587 | ODUFLEX TCMk alarm indication signal |
almOduflexTcm6Exc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13588 | The number of BIP8 bit errors in the ODUFLEX TCMk section exceeds the threshold |
almOduflexTcm6Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13589 | The ODUFLEX TCMk layer signal failure alarm |
almOduflexTcm6Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13590 | Loss of ODUk TCMn serial connection |
almOduflexTcm6Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13591 | ODUFLEX TCMk signal degraded |
almOduflexTcm3Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13592 | Identifiers (API) in the input signals and the expected API |
almOduflexTcm3Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13593 | ODUFLEX TCMk backward defect indication |
almOduflexTcm3Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13594 | ODUFLEX TCMk alarm indication signal |
almOduflexTcm3Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13595 | ODUFLEX TCMk signal degraded |
almOduflexTcm3Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13596 | Loss of ODUk TCMn serial connection |
almOduflexTcm3Oci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13597 | ODUFLEX TCMk open connection indication |
almOduflexTcm3Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13598 | ODUFLEX TCMk signal locked |
almOduflexTcm3Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13599 | The ODUFLEX TCMk layer signal failure alarm |
almOduflexTcm3Exc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13600 | The number of BIP8 bit errors in the ODUFLEX TCMk section exceeds the threshold |
almOduflexTcm2Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13601 | Identifiers (API) in the input signals and the expected API |
almOduflexTcm2Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13602 | ODUFLEX TCMk backward defect indication |
almOduflexTcm2Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13603 | ODUFLEX TCMk alarm indication signal |
almOduflexTcm2Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13604 | ODUFLEX TCMk signal locked |
almOduflexTcm2Oci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13605 | ODUFLEX TCMk backward defect indication |
almOduflexTcm2Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13606 | Loss of ODUk TCMn serial connection |
almOduflexTcm2Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13607 | ODUFLEX TCMk signal degraded |
almOduflexTcm2Exc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13608 | The number of BIP8 bit errors in the ODUFLEX TCMk section exceeds the threshold |
almOduflexTcm2Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13609 | The ODUFLEX TCMk layer signal failure alarm |
almOduflexTcm1Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13610 | Identifiers (API) in the input signals and the expected API |
almOduflexTcm1Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13611 | ODUFLEX TCMk backward defect indication |
almOduflexTcm1Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13612 | ODUFLEX TCMk alarm indication signal |
almOduflexTcm1Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13613 | ODUFLEX TCMk signal locked |
almOduflexTcm1Oci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13614 | ODUFLEX TCMk backward defect indication |
almOduflexTcm1Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13615 | Loss of ODUk TCMn serial connection |
almOduflexTcm1Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13616 | ODUFLEX TCMk signal degraded |
almOduflexTcm1Exc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13617 | The number of BIP8 bit errors in the ODUFLEX TCMk section exceeds the threshold |
almOduflexTcm1Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13618 | The ODUFLEX TCMk layer signal failure alarm |
almFopPm
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13621 | The B bit values in the transmitted and received APS bytes are different |
almEthHiBer
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13622 | Trap of Alarm: 40GE/100GE BIP8 error threshold crossing. |
almEthBip8Sd
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13623 | Trap of Alarm: 40GE/100GE signal degrade. |
almSpanLossExceedEol
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13629 | Trap of Alarm: Span fiber loss exceeding EOL. |
almOmsPwrAdjFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13630 | Trap of Alarm: OMS loss compensation adjustment failure. |
almOmsLossAccumAbn
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13631 | Trap of Alarm: Abnormal accumulated span loss. |
almOaOutPwrAbn
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13632 | Trap of Alarm: Abnormal optical power of the transmit-end OA. |
almPwrUnbalanced
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13633 | Trap of Alarm: Unbalanced optical power flatness. |
almOsnrLossUnbalanced
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13634 | Trap of Alarm: Unbalanced OSNR loss flatness. |
almIpaFault
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13635 | Trap of Alarm: IPA fault. |
almOmsLossMonFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13636 | Trap of Alarm: OMS loss monitoring failure. |
almRLol
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13640 | Loss of lane alignment on receiving line |
almSpanLossUpperGain
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13649 | Trap of Alarm: Span loss upper than the gain compensation value. |
almSpanLossLowerGain
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13650 | Trap of Alarm: Span loss lower than the gain compensation value. |
almBdBpxcMismatch
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13657 | The board access capability mismatches the cross-connect capacity of the backplane in the subrack |
almLcsShortageShelf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13664 | Trap of Alarm: Lack of sufficient licenses or the number of license functions used exceeding the authorized number. |
almAmbientTempOver
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13670 | This alarm is generated when the ambient temperature of the subrack is too high or too low |
almOpu0Msim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13671 | OPU0 multiplex structure identifier mismatch |
almOpuflexMsim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13672 | OPUFLEX multiplex structure identifier mismatch |
almSwdlBdMatchFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13673 | Trap of Alarm: The SWDL_BD_MATCH_FAIL is an alarm indicating that a board fails to match the board software. |
almOtucnBdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13674 | Trap of Alarm: OTUCn backward alarm indication |
almOtucnDeg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13675 | Trap of Alarm: OTUCn signal degrade |
almOtucnTim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13676 | Trap of Alarm: OTUCn trace identifier mismatch |
almOtucnLom
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13677 | Trap of Alarm: Loss of OTUCn multiframe |
almOtucnLof
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13678 | Trap of Alarm: Loss of OTUCn frame |
almOtucnSsf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13679 | Trap of Alarm: OTUCn Server Signal Fail |
almOducnPmAis
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13680 | ODUCn PM alarm indication signal |
almOducnPmSsf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13681 | ODUCn PM Server Signal Fail |
almOducnPmBdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13682 | ODUCn PM backward defect indication |
almOducnPmDeg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13683 | ODUCn PM section excessive BIP8 errors |
almOducnPmTim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13684 | ODUCn PM trace identifier mismatch |
almOducnPlm
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13685 | OPUCn payload label mismatch |
almOpucnMsim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13686 | OPUCn multiplex structure indicator mismatch |
almEncAuthFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13687 | Device authentication at the source and sink fails |
almCfpLos
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13690 | This alarm is generated when no sigal is input to the receive end of the channel on the CFP module |
almPtpAnnounceLos
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13693 | This alarm is reported when the Slave port does not receive any Announce packet within the specified period |
almPtpSyncLos
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13694 | This alarm is reported when the Slave port does not receive any SYNC packet within the specified period |
almPtpDelayRespLos
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13695 | This alarm is reported when the port in P2P mode does not receive any Delay_RESP packet within the specified period |
almPtpPdelayRespLos
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13696 | This alarm is reported when the port in P2P mode does not receive any PDelay_RESP packet within the specified period |
almPtpClkclassFailed
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13697 | This alarm is reported when the CLOCKCLASS value received by a port exceeds the specified threshold |
almOchmLosP
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13706 | The OCHM_LOS_P alarm is reported when an OTU board detects a LOS but no LOS or FDI, OCI alarm is preset at the upper layer |
almOchmOci
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13707 | The OCHM_OCI alarm is actively inserted downstream during optical cross-connection configuration |
almOchmSsf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13708 | The OCHM_SSF alarm is reported when the OCHM_SSF-P and OCHM_SSF-O alarms are present at the same time and suppresses the latter two alarms |
almOchmSsfP
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13709 | The OCHM_SSF_P alarm is reported when the signal payload at the OMS layer is lost or an OChM-layer FDI-P signal is transmitted from the upstream board/site |
almOchmSsfO
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13710 | The OCHM_SSF_O alarm is reported when the signal overhead at the OMS layer is lost or an OChM-layer FDI-O signal is transmitted from the upstream board/site |
almOchmFdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13711 | The OCHM_FDI alarm is reported when the OCHM_FDI-P and OCHM_FDI-O alarms are present at the same time and suppresses the latter two alarms |
almOchmFdiP
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13712 | When a payload LOS is detected at the OMS layer, an OCHM_FDI-P signal is inserted downstream |
almOchmFdiO
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13713 | When an overhead LOS is detected at the OMS layer, an OCHM_FDI-O signal is inserted downstream |
almSwdlBdWeakmatch
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13714 | This alarm is reported when the software of boards on an NE weakly matches the NE software |
almLaserOpenFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13715 | Trap of Alarm: This alarm is reported when the laser fails to be turned on because the OTDR test results do not satisfy the requirements. |
almOPU4LOOMFI
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13716 | Trap of Alarm: Loss of OPU4 multiframe. The alarm is generated when the information about the upstream OPU4 multiframe head does not match the information about the downstream OPU4 multiframe. |
almOtsPmi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13720 | Trap of Alarm: When a local OTS-layer board detects that it has no transmit light or is faulty, it inserts an OTS_PMI signal downstream. |
almOmsPmi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13721 | Trap of Alarm: When a local OMS-layer MUX board detects a fault, it inserts an OMS_PMI signal downstream. |
almStdPtpOffsetOver
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13724 | Trap of Alarm: standard ptptime offset over. |
almCfgDatasaveFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13726 | This alarm is reported when the configuration is saved to the database |
almCfgDatacheckFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13727 | The database will be checked during the NE running |
almSwdlBDNotMatch
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13735 | Trap of Alarm: Board software mismatched. |
almPwdEncriptRisk
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13744 | Trap of Alarm: User password encryption mode risk |
almProPktFlooding
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13746 | Trap of Alarm: Protocol packet flooding attacks detected. |
almSslCertDamaged
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13759 | Trap of Alarm: User-defined SSL certificate file damaged. |
almArpSpoof
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13762 | Trap of Alarm: ARP Spoof. |
almShelfPowerUnconfig
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13763 | Trap of Alarm: This alarm is reported if the power consumption threshold of a subrack is not configured. |
almSslCertToExpire
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13779 | Trap of Alarm: SSL certificate file is to expire. |
almSubrackPortCfgErr
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13880 | Trap of Alarm: Configuration error of cascade ports on subrack |
almInsertLossHigh
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13882 | Trap of Alarm: Fiber fault due to excessive insertion losses. |
almInsertLossMid
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13883 | Trap of Alarm: Fiber fault due to high insertion losses. |
almRxcfgWavedataMis
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13892 | RXCFG_WAVEDATA_MIS |
almOducnPmLck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13923 | Trap of Alarm:ODUCN PM locked defect |
almBdRateMismatch
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13925 | Rate mismatching of a service board and cross-connect board |
almTpmSelfTestFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13926 | The TPM fails to test its hardware |
almTpmStmMismatch
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13927 | TPM_STM_MISMATCH is reported when the measurement result is different from the benchmark |
almChanPwrHigh
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13931 | Trap of Alarm: Excessively High Channel Power. |
almSubrackExceed
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13947 | Trap of Alarm: Number of slave subracks exceeding threshold. |
almLaserTypeMismatch
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13951 | The LASER_TYPE_MISMATCH alarm is an alarm indicating mismatch of optical module types |
almRackConflictScreen
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13952 | Trap of Alarm: Subrack ID conflict isolation. |
almOduSncpWeak
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13953 | This alarm is reported when the working and protection channels of a protection group are configured on the same OTU board, but it is not reported when ASON services are configured |
almKmcKeySyncFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13960 | Trap of Alarm: KMC_KEY_SYNC_FAIL. |
almMpnApsIndi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13961 | This alarm indicates the status of an MPN protection group |
almMpnOppositeCfgErr
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13962 | The?MPN configuration of the peer NE is incorrect |
almMpnApsStop
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13963 | The?automatic switching protocol of MPN protection is stopped |
almXcpDegrade
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13964 | This alarm is reported when the external switching command that affects the automatic switching of cross-connect boards is delivered or the active or standby cross-connect board is faulty |
almLsrKeyUnlock
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13965 | Trap of Alarm: Front panel key unlocked. |
almMcsSwitchBlocked
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13966 | Trap of Alarm: MCS switch blocked. |
almFcAis
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13967 | Fiber channel alarm indication signal, which indicates that an alarm is detected |
almLaserParaErr
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13978 | The LSR_PARA_ERR alarm is an alarm indicating that the parameter stored in the optical module is missing or incorrect |
almEncEMKInit
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13981 | Trap of Alarm: This alarm is generated when services are interrupted due to EMK initialization of encrypted services. |
almBdSessionFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13982 | Trap of Alarm: Session broken between NE and remote board. |
almInsuffcntMemSpac
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13983 | Trap of Alarm: Insufficient memory space. |
almInsuffcntFlshSpace
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13984 | Trap of Alarm: Insufficient flash space. |
almStorageFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13985 | Trap of Alarm: Storage error. |
almOscClkMismatch
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13986 | Trap of Alarm: OSC clock mismatch. |
almAmbientTempFluct
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13987 | This alarm is generated when the ambient temperature of the subrack is fluctuation over 15° |
almlaneoutpwrhigh
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13993 | Trap of Alarm: Excessively high output optical power on the sub-channel. |
almlaneoutpwrlow
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13994 | Trap of Alarm: Excessively low output optical power on the sub-channel. |
almlaneinpwrhigh
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13995 | Trap of Alarm: Excessively high input optical power on the sub-channel. |
almlaneinpwrlow
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13996 | Trap of Alarm: Excessively low input optical power on the sub-channel. |
almlanelos
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.13997 | Trap of Alarm: Loss of signal on the sub-channel of module. |
almOrpCriticalHi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14001 | Trap of Alarm: Excessively high reflection power. |
almFiberBreakPos
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14009 | Trap of Alarm: Fiber broken position indication. |
almFiberAbnPos
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14010 | Trap of Alarm: Fiber abnormal position indication. |
almFiberLossChg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14011 | Trap of Alarm: Fiber loss changing indication. |
almWavelenRepeated
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14025 | Trap of Alarm: Repeated wavelengths found during wavelength locking configuration. |
almPortWllcfgRepeated
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14028 | Trap of Alarm: Repeated wavelength locking configurations on OTU board optical ports. |
almBdFileNotActive
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14029 | Trap of Alarm: Board file not activated. |
almSpectraAnalyseFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14036 | Trap of Alarm: This alarm is reported when the board with the spectrum analysis capability fails to analyze spectrum. |
almSubcardComFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14037 | Trap of Alarm: This alarm is reported when the communication between the CPU module of the board and the subcard fails. |
almSubcardMismatch
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14038 | Trap of Alarm: This alarm is reported when the subcard that is not supported is inserted to the board. |
almSubcardOffline
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14039 | Trap of Alarm: This alarm is reported when the subcard of the board is offline or the subcard hardware is faulty. |
almSubcardUpgradeFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14040 | Trap of Alarm: This alarm is reported when the subcard file of the board fails to be upgraded. |
almPatchOPTimeout
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14041 | Trap of Alarm: The PATCH_OP_TIMEOUT is an alarm indicating that the duration for the patch package to be in the downloading or activation completion state exceeds the upper limit and the patch package needs to be manually processed. |
almPatchInitFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14042 | Trap of Alarm: This alarm is generated when the patch initialization fails. |
almSubcardTempOver
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14050 | Trap of Alarm: Sub-card working temperature threshold-crossing. |
almSplitInstFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14081 | This alarm is reported when a logical 5 |
almWorkparaMis
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14087 | Trap of Alarm: This alarm is reported when the actual and configured working parameters of the board mismatch. |
almPatchMatchNoStart
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14088 | This alarm is reported when the system control board does not launch a board patch match for specific reasons |
almCpldNeedUpdate
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14089 | The board CPLD needs to be upgraded |
almCpldUpdating
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14090 | The board CPLD is being upgraded |
almSdiCrcExc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14092 | This alarm is reported when the software detects that the number of bytes in SDI CRC error frames has exceeded the threshold |
almOduSncpNotHitless
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14093 | The alarm is reported when the ODU SNCP protection group loses hitless protection |
almClntSrvExceedLcs
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14096 | Trap of Alarm: The number of client-side services of a type exceeds the license limit. |
almMacFcsNumSd
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14097 | Trap of Alarm: This alarm indicates signal degrade detected at the MAC layer based on the number of FCS packets. |
almMacFcsNumExc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14098 | Trap of Alarm: This alarm indicates bit error threshold-crossing detected at the MAC layer based on the number of FCS packets. |
almDcnChannelBiterror
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14102 | The DCN_CHANNEL_BITERROR alarm indicates bit errors on the DCN channel, which may cause DCN communication interruption |
almPwrCurrentNoEqual
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14142 | Power output current unbalance |
almBdInMaintenance
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14143 | The board in the maintenance state will be isolated, and the maintenance personnel can perform maintenance operations |
almFiberMisconnect
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14144 | Fiber connections are incorrect |
almInterBdwidthMism
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14145 | Trap of Alarm: The inter-subrack bandwidth of the cluster is not matched.. |
almInterBdwidthInsuf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14146 | Trap of Alarm: The inter-subrack bandwidth of the cluster is insufficient.. |
almDcncfgNotCommit
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14147 | The configured DCN subnet ID has not been committed. |
almIpaAbnormal
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14152 | Trap of Alarm: This alarm occurs when the IPA function is abnormal. |
almApsStatusIndi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14174 | Trap of Alarm: APS status indication. |
almLsrSubmodOffline
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14178 | Trap of Alarm: The alarm is reported when a board detects that the submodule (optical module) is offline. |
almLsrModFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14179 | Trap of Alarm: The LSR_MOD_FAIL alarm indicates that the status of the module on a board is abnormal. |
almSrvTypeMismatch
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14180 | Trap of Alarm: SRV_TYPE_MISMATCH. |
almSoftError
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14181 | Trap of Alarm: A soft error of failure occurs. |
almXcSrvErr
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14183 | Trap of Alarm: XC_SRV_ERR. |
almSwdlIncpkgFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14188 | Trap of Alarm: Failure to load a dynamic incremental package. |
almFpOffline
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14190 | Trap of Alarm: Filler Panel Offline. |
almWaveBlocked
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14191 | Trap of Alarm: Wavelength blocked. |
almTsSyncFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14198 | Trap of Alarm: TS_SYNC_FAIL. |
almOtuWaveMismatch
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14203 | Trap of Alarm: Wavelength configuration mismatch. |
almWclaAbnormal
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14204 | Trap of Alarm: Abnormal optical power detected by WCLA. |
almWclaAdjustFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14205 | Trap of Alarm: WCLA adjustment failure. |
almClusterFiberlenDif
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14206 | Trap of Alarm: Cluster fiber length difference. |
almDpsStaIndi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14209 | Trap of Alarm: Device protection status indication. |
almFibertypeNotConfig
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14210 | Trap of Alarm: The fiber type is not configured. |
almOducnTcm1Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14212 | Trap of Alarm: ODUCN TCM1 Server Signal Fail. |
almOducnTcm2Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14213 | Trap of Alarm: ODUCN TCM2 Server Signal Fail. |
almOducnTcm3Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14214 | Trap of Alarm: ODUCN TCM3 Server Signal Fail. |
almOducnTcm4Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14215 | Trap of Alarm: ODUCN TCM4 Server Signal Fail. |
almOducnTcm5Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14216 | Trap of Alarm: ODUCN TCM5 Server Signal Fail. |
almOducnTcm6Ssf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14217 | Trap of Alarm: ODUCN TCM6 Server Signal Fail. |
almOducnTcm1Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14218 | Trap of Alarm: ODUCN TCM1 alarm indication signal. |
almOducnTcm2Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14219 | Trap of Alarm: ODUCN TCM2 alarm indication signal. |
almOducnTcm3Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14220 | Trap of Alarm: ODUCN TCM3 alarm indication signal. |
almOducnTcm4Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14221 | Trap of Alarm: ODUCN TCM4 alarm indication signal. |
almOducnTcm5Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14222 | Trap of Alarm: ODUCN TCM5 alarm indication signal. |
almOducnTcm6Ais
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14223 | Trap of Alarm: ODUCN TCM6 alarm indication signal. |
almOducnTcm1Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14224 | Trap of Alarm: ODUCN TCM1 locked defect. |
almOducnTcm2Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14225 | Trap of Alarm: ODUCN TCM2 locked defect. |
almOducnTcm3Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14226 | Trap of Alarm: ODUCN TCM3 locked defect. |
almOducnTcm4Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14227 | Trap of Alarm: ODUCN TCM4 locked defect. |
almOducnTcm5Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14228 | Trap of Alarm: ODUCN TCM5 locked defect. |
almOducnTcm6Lck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14229 | Trap of Alarm: ODUCN TCM6 locked defect. |
almOducnTcm1Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14230 | Trap of Alarm: ODUCN TCM1 loss of tandem connection. |
almOducnTcm2Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14231 | Trap of Alarm: ODUCN TCM2 loss of tandem connection. |
almOducnTcm3Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14232 | Trap of Alarm: ODUCN TCM3 loss of tandem connection. |
almOducnTcm4Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14233 | Trap of Alarm: ODUCN TCM4 loss of tandem connection. |
almOducnTcm5Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14234 | Trap of Alarm: ODUCN TCM5 loss of tandem connection. |
almOducnTcm6Ltc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14235 | Trap of Alarm: ODUCN TCM6 loss of tandem connection. |
almOducnTcm1Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14236 | Trap of Alarm: ODUCN TCM1 trace identifier mismatch. |
almOducnTcm2Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14237 | Trap of Alarm: ODUCN TCM2 trace identifier mismatch. |
almOducnTcm3Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14238 | Trap of Alarm: ODUCN TCM3 trace identifier mismatch. |
almOducnTcm4Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14239 | Trap of Alarm: ODUCN TCM4 trace identifier mismatch. |
almOducnTcm5Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14240 | Trap of Alarm: ODUCN TCM5 trace identifier mismatch. |
almOducnTcm6Tim
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14241 | Trap of Alarm: ODUCN TCM6 trace identifier mismatch. |
almOducnTcm1Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14242 | Trap of Alarm: ODUCN TCM1 signal degrade. |
almOducnTcm2Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14243 | Trap of Alarm: ODUCN TCM2 signal degrade. |
almOducnTcm3Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14244 | Trap of Alarm: ODUCN TCM3 signal degrade. |
almOducnTcm4Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14245 | Trap of Alarm: ODUCN TCM4 signal degrade. |
almOducnTcm5Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14246 | Trap of Alarm: ODUCN TCM5 signal degrade. |
almOducnTcm6Deg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14247 | Trap of Alarm: ODUCN TCM6 signal degrade. |
almOducnTcm1Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14248 | Trap of Alarm: ODUCN TCM1 backward defect indication. |
almOducnTcm2Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14249 | Trap of Alarm: ODUCN TCM2 backward defect indication. |
almOducnTcm3Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14250 | Trap of Alarm: ODUCN TCM3 backward defect indication. |
almOducnTcm4Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14251 | Trap of Alarm: ODUCN TCM4 backward defect indication. |
almOducnTcm5Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14252 | Trap of Alarm: ODUCN TCM5 backward defect indication. |
almOducnTcm6Bdi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14253 | Trap of Alarm: ODUCN TCM6 backward defect indication. |
almDbUnsave
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14255 | Trap of Alarm: Configuration persistency prohibited. |
almIntraOtuWeak
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14270 | Trap of Alarm: Poor intra-board 1+1 protection capability. |
almBpOduLoflom
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14271 | Trap of Alarm: Loss of ODU frames and multiframes from the backplane. |
almBdDcnLack
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14288 | Trap of Alarm: Insufficient DCN bandwidth resources of the board. |
almGneConnectFull
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14303 | Trap of Alarm: Excessive gateway connections. |
almSysbusErr
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14306 | Trap of Alarm: SYSTEM BUS Error Alarm. |
almChanPowerDiffOver
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14320 | Trap of Alarm: The difference between the single-wavelength optical power on the working and protection channels exceeds the threshold. |
almSerialLogin
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14322 | Trap of Alarm: Serial login alarm. |
almSecuLogfailed
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14323 | Trap of Alarm: User login failed alarm. |
almOpaVoaMismatch
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14326 | Trap of Alarm: VOA合波衰减和OPA保存的计算值不一样并且超过一定门限则上报此告警. |
almXcsUpgradeInproc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14327 | Trap of Alarm: Cross-upgrade in progress. |
almXcsUpgradeFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14328 | Trap of Alarm: Cross-upgrade failure. |
almXcsUpgradeUncommit
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14329 | Trap of Alarm: Cross-upgrade not committed. |
almXcsDngradeInproc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14330 | Trap of Alarm: Cross-downgrade in progress. |
almXcsDngradeFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14331 | Trap of Alarm: Cross-downgrade failure. |
almXcsRollbackInproc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14332 | Trap of Alarm: Cross-rollback in progress. |
almXcsRollbackFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14333 | Trap of Alarm: Cross-rollback failure. |
almBdTempFluct
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14334 | Trap of Alarm: Fluctuation of working temperature over threshold. |
almFanSpeedFluct
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14335 | Trap of Alarm: Fluctuation of fan speed over threshold. |
almOsnrDeg
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14339 | Trap of Alarm: OSNR degrade. |
almOmsRouteStatusAbn
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14340 | Trap of Alarm: Abnormal OMS route status. |
almDcnSubnetMixedUp
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14373 | Trap of Alarm: DCN_SUBNET_MIXED_UP. |
almOduflexLoa
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14379 | Trap of Alarm: ODUFLEX_LOA. |
almVersionFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14384 | Trap of Alarm: REVERSION_FAIL. |
almNebdOxcDif
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14385 | Trap of Alarm: Optical cross-connect data inconsistency between the NE and boards. |
almTelemetryCommFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14388 | Trap of Alarm: Communication failure between NE and telemetry server. |
almAlienWavelengthAccess
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14392 | Trap of Alarm: Alien wavelength access. |
almClusterShelfIsolate
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14395 | Trap of Alarm: Cluster Subrack Isolation. |
almSubrackRingConnectWeak
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14401 | Trap of Alarm: SUBRACK_RING_CONNECT_WEAK. |
almTbFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14412 | Trap of Alarm: Trustworthiness module abnormality. |
almOxcLicenseOwe
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14429 | Trap of Alarm: Optical-layer license overconsumption alarm. |
almOscPlm
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14430 | Trap of Alarm: OSC payload mismatch. |
almServiceAutocrtFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14435 | Trap of Alarm: Failure of automatic service creation. |
almFlexeRpf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14445 | Trap of Alarm: Remote PHY failure. |
almFlexeLof
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14446 | Trap of Alarm: FlexE FAS loss. |
almFlexeLom
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14447 | Trap of Alarm: FlexE MFAS loss. |
almFlexeGidm
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14448 | Trap of Alarm: FlexE Group ID mismatch. |
almFlexeFmm
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14449 | Trap of Alarm: FlexE Group PHY ID mismatch. |
almFlexeLol
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14450 | Trap of Alarm: Deskew misalignment of multiple FlexE instances. |
almModuleNotAuthenticated
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14451 | Trap of Alarm: Module is not authenticated. |
almEnhanceSwitchFar
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14457 | Trap of Alarm: OMS 1+1 protection switching alarm. |
almIpaAuxiliaryMis
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.14464 | Trap of Alarm: Missing of the IPA auxiliary detection board. |
almTempAlarm
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.166 | The temperature threshold crossing alarm |
almB1Sd
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.175 | The B1_SD is an alarm indicating that regenerator section B1 signals received over the line are degraded |
almK1K2M
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.180 | The K1_K2_M is an alarm indicating the mismatch between the K1 and K2 bytes |
almK2M
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.181 | The K2_M is an alarm of K2 byte mismatch |
almExtSyncLos
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.184 | The EXT_SYNC_LOS is an alarm indicating the loss of external clock source |
almDBErr
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.185 | Trap of Alarm: Data base error |
almMutLos
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.186 | The MUT_LOS is an alarm indicating that the coupled signals are lost |
almChanLos
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.187 | Trap of Alarm: Loss of single-wavelength signal. |
almChanAdd
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.188 | Trap of Alarm: (CHAN_ADD)Addition of single-wavelength signal. |
almTd
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.189 | Trap of Alarm: Laser transmitter degrade |
almNoBdPara
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.190 | The NO_BD_PARA is an alarm indicating that the board parameters are not set |
almPumpCoolExc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.192 | Cool current of pump laser over threshold |
almS1SynChange
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.193 | The S1_SYN_CHANGE is an alarm indicating that, in the S1 byte mode, the clock source is switched |
almNestateInstall
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.197 | Trap of Alarm: NE in install state. |
almProtectMode
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.198 | Trap of Alarm: Databases in protection mode |
almCommFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.199 | Trap of Alarm: Inter-board communication failure |
almSecuAlm
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.200 | Trap of Alarm: Security alarm |
almPowerDiffOver
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.211 | Power difference between optical monitoring active and standby crossed the threshold |
almNesfLost
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.215 | Trap of Alarm: Loss of NE software. |
almCrcExc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.224 | Trap of Alarm: almCrcExc. |
almSncpFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.234 | Trap of Alarm: SNCP switching failure. |
almHardBad
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.236 | Trap of Alarm: This alarm occurs when a hardware exception is detected |
almLoopback
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.240 | Trap of Alarm: Loopback |
almInPwrAbn
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.25 | The IN_PWR_ABN is an alarm indicating that the input optical power is asbnormal |
almFanCommFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.256 | Trap of Alarm: The communication of fans fails |
almSWDLPkgNoBDSoft
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.2569 | Trap of Alarm: No board software in the software package |
almRollBackFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.2570 | Trap of Alarm: NE rollback failed |
almCommitFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.2571 | Trap of Alarm: Commit failure |
almSWDLInProcess
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.2572 | Trap of Alarm: Software downloading in process |
almSwdlPkgverMisMatch
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.2573 | Trap of Alarm: Inconsistency of software package versions |
almSwdlAutoMatchInh
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.2574 | Trap of Alarm: Automatic match inhibited |
almNebdXcDif
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.259 | Trap of Alarm: Inconsistency between NE and board cross-connect matrix data. |
almOutPwrAbn
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.26 | The OUT_PWR_ABN is an alarm indicating that the output optical power is abnormal |
almLinkErr
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.261 | This alarm occurs when the Ethernet connection is incorrect and the port negotiation fails |
almWOffline
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.262 | The W_OFFLINE is an alarm indicating that the front panel of a board is out of position |
almOol
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.263 | The OOL is an alarm indicating that the phase-locked loop is out of lock |
almAdCheckFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.269 | AD (analog to digital converter) self check failure alarm |
almModuleCoolcurOver
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.270 | Trap of Alarm: Alarm of module cooling current threshold crossing. |
almModuleTempOver
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.271 | Trap of Alarm: Module temperature exceeds the threshold. |
almTempOver
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.28 | Trap of Alarm: Board working temperature over threshold |
almTempHigh
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.29 | Trap of Alarm: Laser temperature is too high |
almPortswitchFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.295 | Trap of Alarm: Optical switch transfer failure. |
almAlmAls
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.296 | The ALM_ALS is an automatic laser shutdown (ALS) alarm |
almRmonAlmInbadoctsOver
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.299 | Rmon Alm Inbadocts Over |
almRLoc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.3 | Loss of clock on receiving line |
almTempLow
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.30 | Trap of Alarm: Laser temperature is too low |
almInPwrHigh
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.31 | Trap of Alarm: Input optical power is too high |
almInPwrLow
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.32 | Trap of Alarm: Input optical power is too low |
almSumInpwrHi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.323 | The SUM_INPWR_HI is an alarm indicating that the combined input optical power of the laser of the colored optical module is over high |
almSumInpwrLow
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.324 | Sum input optical power is too low |
almOaLowGain
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.327 | The OA_LOW_GAIN is an alarm indicating that the gain of the optical amplifier declines |
almMsAis
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.33 | The MS_AIS is an indication alarm in the multiplex section |
almClkNoTraceMode
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.333 | The CLK_NO_TRACE_MODE is an alarm indicating that the clock enters into a non-tracing running mode |
almBeffecExc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.335 | Trap of Alarm: Bit errors over threshold before FEC |
almApsManualStop
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.336 | The ALM_APS_MANU_STOP is an alarm indicating that the MSP protocol is manually stopped |
almSccLoc
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.342 | Trap of Alarm: Loss of SCC clock source. |
almLaserClosed
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.364 | The LASER_CLOSED is an alarm indicating that the laser on the line board is closed after the laser shutdown command is received |
almBusErr
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.377 | The BUS_ERR is a bus error alarm |
almSyncLockoff
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.390 | The SYNC_LOCKOFF is an alarm indicating that the clock source in the priority list is locked |
almSyncFMSwitch
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.391 | The SYNC_F_M_SWITCH is an alarm indicating the forced or manual switching state of a clock source |
almLaserModErr
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.393 | The LASER_MOD_ERR is an alarm indicating mismatch of optical modules |
almApsIndi
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.41 | The APS_INDI is an alarm indicating the APS state |
almShelfWrongConnect
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.41987 | The network cables between subracks are incorrectly connected (that is, the network cables are cross-connected) |
almApsFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.42 | The APS_FAIL is an indication alarm of APS protection switching failure |
almAlmHangup
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.420 | Trap of Alarm: the orderwire phone is in the off-hook state for a long time. |
almRmRlos
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.42184 | Trap of Alarm: Loss of input reverse pump light. |
almSccChange
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.422 | Trap of Alarm: SCC Change Alarm. |
almSlaveWorking
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.424 | The SLAVE_WORKING is an alarm indicating that the protection board is working |
almModComFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.432 | Trap of Alarm: Module Communicate Failure. |
almHscUnavail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.440 | Trap of Alarm: HOT SWITCH CONTROL UNAVAILABLE. |
almAlmDataRlos
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.441 | Trap of Alarm: Ethernet Port Receive No Data. |
almAlmDataTlos
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.442 | Trap of Alarm: Ethernet Port Transmit No Data. |
almBiosStatus
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.449 | The BIOS_STATUS is an alarm indicating that the board cannot reach a normal software running status |
almLsrWillDie
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.56 | Trap of Alarm: Laser will be out of work |
almLsrNoFited
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.57 | The LSR_NO_FITED is an alarm indicating that the laser is not installed |
almActiveTimeout
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.573 | Trap of Alarm: Activation time out |
almSwdlNepkgcheck
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.574 | Trap of Alarm: Loss of file |
almSwdlChgmngMismatch
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.575 | Trap of Alarm: NE software and the board software do not match |
almNodeidMm
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.578 | Trap of Alarm: Node Id Mismatch. |
almLsrBcmAlm
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.58 | The LSR_BCM_ALM is an alarm indicating that the bias current of the laser crosses the threshold |
almBootRomBad
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.584 | Trap of Alarm: BOOTROM_CheckSum_Alarm |
almSyncFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.591 | The SYNC_FAIL is an alarm indicating that the batch backup of the databases of the active and standby SCC boards fails |
almNoBdSoft
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.6 | Trap of Alarm: No board software |
almLsrCoolAlm
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.60 | The LSR_COOL_ALM is an alarm indicating that the cooling current of the laser crosses the threshold |
almMsApsIndiEx
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.600 | Trap of Alarm: MS Auto Protect Switch Indicator Expand. |
almLaserModuleMismatch
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.606 | Trap of Alarm: Laser module is mismatch |
almRtcFault
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.624 | Trap of Alarm: RTC time fail alarm |
almBDNotInstalled
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.625 | Trap of Alarm: Logic board not installed |
almOutPwrHigh
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.63 | Trap of Alarm: Output optical power too high |
almLaserShut
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.63509 | The LASER_SHUT is an alarm indicating that the laser of the board is shut down |
almHardNonsupport
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.63537 | This alarm is reported when the hardware does not support the configuration delivered by the SCC board or the total power of all boards is beyond the permitted range |
almRemSf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.63604 | Trap of Alarm: Remote Singal Unequip |
almRemSd
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.63605 | Trap of Alarm: Remote Singal Degrade Alarm Indication |
almNeidConflict
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.63625 | Trap of Alarm: NEID_CONFLICT. |
almPortOffline
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.63629 | Trap of Alarm: Port module offline |
almThunderAlm
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.63635 | Thunder protection circuit failure alarm |
almLaserModErrEx
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.63644 | Trap of Alarm: almLaserModErrEx |
almOtuPwrLow
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.64 | Trap of Alarm: Output optical power too low |
almPumTemAlm
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.68 | Working temperature of the pump laser exceeds the threshold |
almPumBcmAlm
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.69 | This alarm occurs when the pump laser bias current of the optical amplifier unit crosses the threshold |
almRLof
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.8 | Loss of frame on receiving line |
almJ0Mm
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.87 | Trap of Alarm: Section trace identifier mismatch. |
almTf
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.9 | Trap of Alarm: Laser transmission Failure |
almWRFail
| .1.3.6.1.4.1.2011.2.25.3.40.40.40.99 | Trap of Alarm: Reading or writing single chip register failed. |