OMNITRON-GPOE-NOTIFICATION-MIB
Omnitron GPoE Notification MIB for use with v2.0 GPoE and GHPoE and NetOutlook
Copyright 2018 Omnitron Systems Technology, Inc. All rights reserved
- Source file
OMNITRON-GPOE-NOTIFICATION-MIB- Last revised
- Identity
omnitronGpoeNotificationMib- Base OID
1.3.6.1.4.1.7342.100- Objects
- 7 scalars · 2 columns
- Tables
- 1 tables
Net-SNMP examples using the omnitron MIB directory
These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.
Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'OMNITRON-GPOE-NOTIFICATION-MIB' -M '/opt/observium/mibs/omnitron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'OMNITRON-GPOE-NOTIFICATION-MIB::omnitronGpoeNotificationMib'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'OMNITRON-GPOE-NOTIFICATION-MIB' -M '/opt/observium/mibs/omnitron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'OMNITRON-GPOE-NOTIFICATION-MIB::omnitronGpoeNotificationMib'
Imported Objects
| OMNITRON-TC-MIB | omnitron |
| SNMPv2-CONF | MODULE-COMPLIANCE (no object page) NOTIFICATION-GROUP (no object page) OBJECT-GROUP (no object page) |
| SNMPv2-SMI | MODULE-IDENTITY (no object page) NOTIFICATION-TYPE (no object page) OBJECT-TYPE (no object page) Unsigned32 |
| SNMPv2-TC | DisplayString |
Objects
ostGpoeNotificationObjects
omnitronGpoeNotificationMib ·
.1.3.6.1.4.1.7342.100.1
| Object | Syntax | OID |
|---|---|---|
| gpoeTrapCode | OctetString | .1.3.6.1.4.1.7342.100.1.1 |
| gpoeTrapIpString | OctetString | .1.3.6.1.4.1.7342.100.1.2 |
| gpoeTrapModuleDescription | OctetString | .1.3.6.1.4.1.7342.100.1.3 |
| gpoeSourceIpString | OctetString | .1.3.6.1.4.1.7342.100.1.4 |
| gpoeUsername | OctetString | .1.3.6.1.4.1.7342.100.1.5 |
| gpoePoeStatus | Bits | .1.3.6.1.4.1.7342.100.1.6 |
ostGpoeNotificationGlobalObjects
omnitronGpoeNotificationMib ·
.1.3.6.1.4.1.7342.100.2
| Object | Syntax | OID |
|---|---|---|
| ostGpoeNotificationCfgSetClearAll | Enumerationr/w | .1.3.6.1.4.1.7342.100.2.1 |
.1.3.6.1.4.1.7342.100.3
· 2 columns
This table supports the configuration and source filtering of SNMP notifications generated by Omnitron management modules.
ostGpoeNotificationCfgEntry
.1.3.6.1.4.1.7342.100.3.1
| Column | Syntax | OID |
|---|---|---|
| gpoeNotificationCfgTrapNum | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.7342.100.3.1.1 |
| gpoeNotificationCfgFilteringEnable | Enumerationr/w | .1.3.6.1.4.1.7342.100.3.1.2 |
Notifications / Traps (52)
| Notification | Variable bindings | OID |
|---|---|---|
| gpoeModuleColdStart | .1.3.6.1.4.1.7342.100.0.1 | |
| gpoeSecondaryLinkUp | .1.3.6.1.4.1.7342.100.0.10 | |
| gpoeSecondaryLinkDown | .1.3.6.1.4.1.7342.100.0.11 | |
| gpoeStandbyLinkUp | .1.3.6.1.4.1.7342.100.0.12 | |
| gpoeStandbyLinkDown | .1.3.6.1.4.1.7342.100.0.13 | |
| gpoeLoopPreventionBlock | .1.3.6.1.4.1.7342.100.0.14 | |
| gpoeLoopPreventionClear | .1.3.6.1.4.1.7342.100.0.15 | |
| gpoeHardwareDipSwitchChanged | .1.3.6.1.4.1.7342.100.0.16 | |
| gpoeSoftwareDipSwitchChanged | .1.3.6.1.4.1.7342.100.0.17 | |
| gpoeOutputRelay | .1.3.6.1.4.1.7342.100.0.18 | |
| gpoeInputPinStatus | .1.3.6.1.4.1.7342.100.0.19 | |
| gpoeModuleReset | .1.3.6.1.4.1.7342.100.0.2 | |
| gpoeModuleConfigurationChange | .1.3.6.1.4.1.7342.100.0.20 | |
| gpoeModuleOverTemperature | .1.3.6.1.4.1.7342.100.0.21 | |
| gpoeModuleNormalTemperature | .1.3.6.1.4.1.7342.100.0.22 | |
| gpoeModuleVoltageOutOfRange | .1.3.6.1.4.1.7342.100.0.23 | |
| gpoeModuleVoltageRangeNormal | .1.3.6.1.4.1.7342.100.0.24 | |
| gpoePoePdStatusError | .1.3.6.1.4.1.7342.100.0.25 | |
| gpoePoePdStatusNormal | .1.3.6.1.4.1.7342.100.0.26 | |
| gpoeAclAccessDenied | .1.3.6.1.4.1.7342.100.0.27 | |
| gpoeTelnetAuthenticationFailure | .1.3.6.1.4.1.7342.100.0.28 | |
| gpoeTelnetSessionStarted | .1.3.6.1.4.1.7342.100.0.29 | |
| gpoeTelnetSessionStopped | .1.3.6.1.4.1.7342.100.0.30 | |
| gpoeFtpAuthenticationFailure | .1.3.6.1.4.1.7342.100.0.31 | |
| gpoeFtpSessionStarted | .1.3.6.1.4.1.7342.100.0.32 | |
| gpoeFtpSessionStopped | .1.3.6.1.4.1.7342.100.0.33 | |
| gpoeSerialConsoleSessionStarted | .1.3.6.1.4.1.7342.100.0.34 | |
| gpoeSerialConsoleSessionStopped | .1.3.6.1.4.1.7342.100.0.35 | |
| gpoeSshAuthenticationFailure | .1.3.6.1.4.1.7342.100.0.36 | |
| gpoeSshSessionStarted | .1.3.6.1.4.1.7342.100.0.37 | |
| gpoeSshSessionStopped | .1.3.6.1.4.1.7342.100.0.38 | |
| gpoeWrongPasswordCountExceeded | .1.3.6.1.4.1.7342.100.0.39 | |
| gpoeModulePowerRemoved | .1.3.6.1.4.1.7342.100.0.4 | |
| gpoeSfpInserted | .1.3.6.1.4.1.7342.100.0.40 | |
| gpoeSfpRemoved | .1.3.6.1.4.1.7342.100.0.41 | |
| gpoeSfpTxLowThreshold | .1.3.6.1.4.1.7342.100.0.42 | |
| gpoeSfpTxHighThreshold | .1.3.6.1.4.1.7342.100.0.43 | |
| gpoeSfpCurrentBiasLowThreshold | .1.3.6.1.4.1.7342.100.0.44 | |
| gpoeSfpCurrentBiasHighThreshold | .1.3.6.1.4.1.7342.100.0.45 | |
| gpoeSfp33VLowThreshold | .1.3.6.1.4.1.7342.100.0.46 | |
| gpoeSfp33VHighThreshold | .1.3.6.1.4.1.7342.100.0.47 | |
| gpoeSfpTempLowThreshold | .1.3.6.1.4.1.7342.100.0.48 | |
| gpoeSfpTempHighThreshold | .1.3.6.1.4.1.7342.100.0.49 | |
| gpoeModulePowerApplied | .1.3.6.1.4.1.7342.100.0.5 | |
| gpoeSfpRxLowThreshold | .1.3.6.1.4.1.7342.100.0.50 | |
| gpoeSfpRxHighThreshold | .1.3.6.1.4.1.7342.100.0.51 | |
| gpoeSfpNormal | .1.3.6.1.4.1.7342.100.0.52 | |
| gpoeModuleConfigurationFileCorrupted | .1.3.6.1.4.1.7342.100.0.53 | |
| gpoeLinkDown | .1.3.6.1.4.1.7342.100.0.6 | |
| gpoeLinkUp | .1.3.6.1.4.1.7342.100.0.7 | |
| gpoePrimaryLinkUp | .1.3.6.1.4.1.7342.100.0.8 | |
| gpoePrimaryLinkDown | .1.3.6.1.4.1.7342.100.0.9 |
Conformance Groups (2)
ostGpoeNotificationGroup .1.3.6.1.4.1.7342.100.5.1
Notifications (52)
ostGpoeNotificationObjectGroup .1.3.6.1.4.1.7342.100.5.2
Members (8)
Compliance Statements (1)
ostGpoeTrapCompliance .1.3.6.1.4.1.7342.100.4.1
Dependencies (4) 4 direct Show tree and compile order Hide dependency details
Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.
Dependency tree
Dependency-first compile order
- SNMPv2-SMIrfc
- SNMPv2-TCrfc
- OMNITRON-TC-MIBomnitron
- SNMPv2-CONFrfc
- OMNITRON-GPOE-NOTIFICATION-MIBomnitronselected