.1.3.6.1.4.1.7342.9.1.2.1 · 1 row entry · 15 columns
Uses the omnitron variant from /opt/observium/mibs/omnitron.
Command help
Walk ostDs1ModuleSettingsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'OMNITRON-DS1-MIB' -M '/opt/observium/mibs/omnitron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'OMNITRON-DS1-MIB::ostDs1ModuleSettingsTable'
This supports OST DS1 module settings.
ostDs1ModuleSettingsEntry row .1.3.6.1.4.1.7342.9.1.2.1.1
OST DS1 module settings table entry.
Column Syntax OID
The module chassis and slot numbers.
Base 10 Format: CCSS where
CC is the chassis index, 1 to 99
SS is the slot index, 1 to 99
OMNITRON-TC-MIBOstModuleSingleIndex
Type Constraints:
range: 101..9999
.1.3.6.1.4.1.7342.9.1.2.1.1.1
Set the inband loopback activation code.
fac1(1) = FAC1 (1100)
fac2(2) = FAC2 (11000)
fac3(3) = FAC3 (10000)
userdefined(4) = xxxxxxxx
disabled(5) = disabled
Enumerationr/w
Enumerated Values:
1fac1
2fac2
3fac3
4userdefined
5disabled
.1.3.6.1.4.1.7342.9.1.2.1.1.2
Set the user defined inband loopback activation code.
The format of the value of this object is a text string of '0' and '1' ASCII characters from 3 to 8 characters long.
This object is used when ostDs1ModuleInbandLoopb…
OctetStringr/w
Constraints:
range: 3-8
.1.3.6.1.4.1.7342.9.1.2.1.1.3
Set the inband loopback deactivation code.
fac1(1) = FAC1 (1110)
fac2(2) = FAC2 (11100)
fac3(3) = FAC3 (100)
userdefined(4) = xxxxxxxx
disabled(5) = disabled
Enumerationr/w
Enumerated Values:
1fac1
2fac2
3fac3
4userdefined
5disabled
.1.3.6.1.4.1.7342.9.1.2.1.1.4
Set the user defined inband loopback deactivation code.
The format of the value of this object is a text string of '0' and '1' ASCII characters from 3 to 8 characters long.
This object is used when ostDs1ModuleInbandLoo…
OctetStringr/w
Constraints:
range: 3-8
.1.3.6.1.4.1.7342.9.1.2.1.1.5
Set the outband loopback activation code.
payload(1) = Payload (00101000)
userdefined(2) = 0xxxxxx0
disabled(3) = disabled
Enumerationr/w
Enumerated Values:
1payload
2userdefined
3disabled
.1.3.6.1.4.1.7342.9.1.2.1.1.6
Set the user defined outband loopback activation code.
The format of the value of this object is a 6 ASCII character long text string of '0' and '1' characters.
The 6 bits are used to generate the 8 bit user defined cod…
OctetStringr/w
Constraints:
range: 6-6
.1.3.6.1.4.1.7342.9.1.2.1.1.7
Set the outband loopback deactivation code.
payload(1) = Payload (00100100)
userdefined(2) = 0xxxxxx0
disabled(3) = disabled
Enumerationr/w
Enumerated Values:
1payload
2userdefined
3disabled
.1.3.6.1.4.1.7342.9.1.2.1.1.8
Set the user defined outband loopback deactivation code.
The format of the value of this object is a 6 ASCII character long text string of '0' and '1' characters.
The 6 bits are used to generate the 8 bit user defined c…
OctetStringr/w
Constraints:
range: 6-6
.1.3.6.1.4.1.7342.9.1.2.1.1.9
This object sets the clock draft mode.

standard(1) sets the standard clock drift mode for Stratum 3 or better
general(2) sets the general clock mode (wide clock acquisition)
Enumerationr/w
Enumerated Values:
1standard
2general
.1.3.6.1.4.1.7342.9.1.2.1.1.10
This object specifies the loopback timeout in minutes.

A value of 0 indicates there is no loopback timeout.
minutesUnsigned32r/w
Constraints:
range: 0-60
.1.3.6.1.4.1.7342.9.1.2.1.1.11
This object sets the internal module clock source if DIP switch 22 is
OFF. If DIP switch 22 is ON the value of this object is ignored.

t1RemoteSource(1) sets the Adaptive clock source from remote devi…
Enumerationr/w
Enumerated Values:
1t1RemoteSource
2t1LocalSource
.1.3.6.1.4.1.7342.9.1.2.1.1.12
This object sets the module to generate AIS when an AIS condition is
detected.

aisEnabled(1) Enables the generation of AIS
aisDisabled(2) Disables the generation of AIS
Enumerationr/w
Enumerated Values:
1aisEnabled
2aisDisabled
.1.3.6.1.4.1.7342.9.1.2.1.1.13
This object specifies the amount time that an AIS condition must be
valid when AIS is not being generated before an AIS is generated by the
module.
secondsUnsigned32r/w
Constraints:
range: 0-3600
.1.3.6.1.4.1.7342.9.1.2.1.1.14
This object specifies the amount time that an AIS will be generated when
a valid AIS condition has been detected for the amount of time indicated
by ostDs1ModuleAisDetectionTime.
secondsUnsigned32r/w
Constraints:
range: 1-3600
.1.3.6.1.4.1.7342.9.1.2.1.1.15
.1.3.6.1.4.1.7342.9.1.3.1 · 1 row entry · 5 columns
Uses the omnitron variant from /opt/observium/mibs/omnitron.
Command help
Walk ostDs1ModuleStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'OMNITRON-DS1-MIB' -M '/opt/observium/mibs/omnitron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'OMNITRON-DS1-MIB::ostDs1ModuleStatusTable'
This supports OST DS1 module status.
ostDs1ModuleStatusEntry row .1.3.6.1.4.1.7342.9.1.3.1.1
OST DS1 module status table entry.
Column Syntax OID
The module chassis and slot numbers.
Base 10 Format: CCSS where
CC is the chassis index, 1 to 99
SS is the slot index, 1 to 99
OMNITRON-TC-MIBOstModuleSingleIndex
Type Constraints:
range: 101..9999
.1.3.6.1.4.1.7342.9.1.3.1.1.1
When true, the module places the recovered clock from Port 1 onto the Clock
Coax I/O Connector as selected by ostDs1ModuleOneClockMode and DIP switch 22.

When false, the module uses the clock provided on …
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.7342.9.1.3.1.1.2
The FPGA code revision of the baseboard.
Unsigned32
Constraints:
range: 0-999999
.1.3.6.1.4.1.7342.9.1.3.1.1.3
The FPGA code revision of the mezzanine board.
Unsigned32
Constraints:
range: 0-999999
.1.3.6.1.4.1.7342.9.1.3.1.1.4
The status of the TDM mux module.
muxStartup(1) The module is in initial startup and testing
muxInitializing(2) The module is completing initialization but hasn't started finding a partner
muxInitia…
Enumeration
Enumerated Values:
1muxStartup
2muxInitializing
3muxInitializingNoPeer
4muxInitializingPeering
5muxReadyPeering
6muxReadyPeered
7muxReadyNoPeer
.1.3.6.1.4.1.7342.9.1.3.1.1.5
.1.3.6.1.4.1.7342.9.1.4.1 · 1 row entry · 5 columns
Uses the omnitron variant from /opt/observium/mibs/omnitron.
Command help
Walk ostDs1PortStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'OMNITRON-DS1-MIB' -M '/opt/observium/mibs/omnitron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'OMNITRON-DS1-MIB::ostDs1PortStatusTable'
This supports OST DS1 port status.
ostDs1PortStatusEntry row .1.3.6.1.4.1.7342.9.1.4.1.1
OST DS1 port status table entry.
Indexes
Column Syntax OID
Chassis, module and port indices to which this interface belongs.
OMNITRON-TC-MIBOstPortSingleIndex
Type Constraints:
range: 10101..999999
.1.3.6.1.4.1.7342.9.1.4.1.1.1
Clock type.
OMNITRON-TC-MIBOstPortClockType
Type Values:
1adaptiveIdle
2adaptiveAcqu
3adaptiveTrk1
4adaptiveTrk2
5holdOver
6coax
7internal
8line
.1.3.6.1.4.1.7342.9.1.4.1.1.2
Clock frequency in hundreths of Hz
OMNITRON-TC-MIBOstClockFreq .1.3.6.1.4.1.7342.9.1.4.1.1.3
Clock error in parts per billion (ppb).
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.7342.9.1.4.1.1.4
Indicates where coax input clock is valid.

valid(1) indicates input coax clock is valid
invalid(2) indicates input coax clock is invalid
unknown(3) indicates no input coax clock or state of input clo…
Enumeration
Enumerated Values:
1valid
2invalid
3unknown
.1.3.6.1.4.1.7342.9.1.4.1.1.5
.1.3.6.1.4.1.7342.9.1.5.1 · 1 row entry · 1 columns
Uses the omnitron variant from /opt/observium/mibs/omnitron.
Command help
Walk ostdsx1FarEndCurrentTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'OMNITRON-DS1-MIB' -M '/opt/observium/mibs/omnitron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'OMNITRON-DS1-MIB::ostdsx1FarEndCurrentTable'
The DS1 Fare End Current table contains various statistics
being collected for the far end current 15-minute interval.
ostdsx1FarEndCurrentEntry row .1.3.6.1.4.1.7342.9.1.5.1.1
An entry in the DS1 Far End Current table.
Column Syntax OID
The number of Line Coding Violations (LCVs).
PerfHist-TC-MIBPerfCurrentCount .1.3.6.1.4.1.7342.9.1.5.1.1.1
.1.3.6.1.4.1.7342.9.1.5.2 · 1 row entry · 1 columns
Uses the omnitron variant from /opt/observium/mibs/omnitron.
Command help
Walk ostdsx1FarEndIntervalTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'OMNITRON-DS1-MIB' -M '/opt/observium/mibs/omnitron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'OMNITRON-DS1-MIB::ostdsx1FarEndIntervalTable'
The DS1 Far End Interval table contains various
statistics collected by each DS1 interface over
the previous 24 hours of operation.  The past 24
hours are broken into 96 completed 15-minute
intervals.  Each row in this table represents one
such interval (identified by dsx1IntervalNumber)
for one specific instance (identified by
dsx1IntervalIndex).
ostdsx1FarEndIntervalEntry row .1.3.6.1.4.1.7342.9.1.5.2.1
An entry in the DS1 Interval table.
Column Syntax OID
The number of far end Line Coding Violations.
PerfHist-TC-MIBPerfIntervalCount .1.3.6.1.4.1.7342.9.1.5.2.1.1
.1.3.6.1.4.1.7342.9.1.5.3 · 1 row entry · 1 columns
Uses the omnitron variant from /opt/observium/mibs/omnitron.
Command help
Walk ostdsx1FarEndTotalTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'OMNITRON-DS1-MIB' -M '/opt/observium/mibs/omnitron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'OMNITRON-DS1-MIB::ostdsx1FarEndTotalTable'
The DS1 Far End Total table contains the cumulative sum
of the various statistics for the 24-hour period
preceding the current interval.
ostdsx1FarEndTotalEntry row .1.3.6.1.4.1.7342.9.1.5.3.1
An entry in the DS1 Far End Total table.
Column Syntax OID
The number of Line Coding Violations (LCVs) encountered by a DS1 far end
interface in the current 15-minute interval. Invalid 15-minute intervals
count as 0.
PerfHist-TC-MIBPerfTotalCount .1.3.6.1.4.1.7342.9.1.5.3.1.1