OLD-DNOS-BOXSERVICES-PRIVATE-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
4
Rows
4
Columns
17
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.6 · 1 row entry · 5 columns
Uses the dell variant from /opt/observium/mibs/dell.
Command help
Walk boxServicesFansTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'OLD-DNOS-BOXSERVICES-PRIVATE-MIB' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'OLD-DNOS-BOXSERVICES-PRIVATE-MIB::boxServicesFansTable'
Fan
boxServicesFansEntry row .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.6.1
Box Services Fan Entry
Column Syntax OID
boxServicesFansIndexUnique index of fan table entryInteger32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.6.1.1
boxServicesFanItemTypeThe type of fanEnumeration
Enumerated Values:
1fixed
2removable
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.6.1.2
boxServicesFanItemStateThe status of fanEnumeration
Enumerated Values:
1notpresent
2operational
3failed
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.6.1.3
boxServicesFanSpeedThe speed of fanSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.6.1.4
boxServicesFanDutyLevelThe duty level of fan, in percentsSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.6.1.5
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.7 · 1 row entry · 3 columns
Uses the dell variant from /opt/observium/mibs/dell.
Command help
Walk boxServicesPowSuppliesTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'OLD-DNOS-BOXSERVICES-PRIVATE-MIB' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'OLD-DNOS-BOXSERVICES-PRIVATE-MIB::boxServicesPowSuppliesTable'
Power supply
boxServicesPowSuppliesEntry row .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.7.1
Box Services Power Supply Entry
Column Syntax OID
boxServicesPowSupplyIndexUnique index of power supply table entryInteger32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.7.1.1
boxServicesPowSupplyItemTypeThe type of power supplyEnumeration
Enumerated Values:
1fixed
2removable
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.7.1.2
boxServicesPowSupplyItemStateThe status of power supplyEnumeration
Enumerated Values:
1notpresent
2operational
3failed
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.7.1.3
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.8 · 1 row entry · 4 columns
Uses the dell variant from /opt/observium/mibs/dell.
Command help
Walk boxServicesTempSensorsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'OLD-DNOS-BOXSERVICES-PRIVATE-MIB' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'OLD-DNOS-BOXSERVICES-PRIVATE-MIB::boxServicesTempSensorsTable'
Temperature sensor
          
This table has been obsoleted by boxServicesStackTempSensorsTable
boxServicesTempSensorsEntry row .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.8.1
Box Services Temperature Sensor Entry
Column Syntax OID
boxServicesTempSensorIndexUnique index of temperature sensor table entryInteger32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.8.1.1
boxServicesTempSensorTypeThe type of temperature sensorEnumeration
Enumerated Values:
1fixed
2removable
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.8.1.2
boxServicesTempSensorStateThe state of temperature sensorEnumeration
Enumerated Values:
1normal
2warning
3critical
4shutdown
5notpresent
6notoperational
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.8.1.3
boxServicesTempSensorTemperatureThe temperature value reported by sensorSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.8.1.4
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9 · 1 row entry · 5 columns
Uses the dell variant from /opt/observium/mibs/dell.
Command help
Walk boxServicesStackTempSensorsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'OLD-DNOS-BOXSERVICES-PRIVATE-MIB' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'OLD-DNOS-BOXSERVICES-PRIVATE-MIB::boxServicesStackTempSensorsTable'
Temperature sensor
boxServicesStackTempSensorsEntry row .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9.1
Box Services Temperature Sensor Entry
Column Syntax OID
boxServicesUnitIndexIndex of a stack unitInteger32
Constraints:
range: 1-8
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9.1.1
boxServicesStackTempSensorIndexUnique index of temperature sensor table entryInteger32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9.1.2
boxServicesStackTempSensorTypeThe type of temperature sensorEnumeration
Enumerated Values:
1fixed
2removable
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9.1.3
boxServicesStackTempSensorStateThe state of temperature sensorEnumeration
Enumerated Values:
1normal
2warning
3critical
4shutdown
5notpresent
6notoperational
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9.1.4
boxServicesStackTempSensorTemperatureThe temperature value reported by sensorSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9.1.5