OGTRAPv2-MIB

Source file
OGTRAPv2-MIB
Last revised
Not declared
Imported Objects
RFC-1212 OBJECT-TYPE (no object page)
RFC-1215 TRAP-TYPE (no object page)
RFC1155-SMI enterprises
Objects (92)
.1.3.6.1.4.1.25049
.1.3.6.1.4.1.25049.2
.1.3.6.1.4.1.25049.2.0
.1.3.6.1.4.1.25049.2.101
.1.3.6.1.4.1.25049.2.101.1
.1.3.6.1.4.1.25049.2.101.1.1
.1.3.6.1.4.1.25049.2.101.1.1.1
.1.3.6.1.4.1.25049.2.101.1.1.1.1
ogAlarmIndex mandatory
.1.3.6.1.4.1.25049.2.101.1.1.1.1.1
ogAlarmUser mandatory
OctetString
.1.3.6.1.4.1.25049.2.101.1.1.1.1.10
.1.3.6.1.4.1.25049.2.101.1.1.1.1.11
.1.3.6.1.4.1.25049.2.101.1.1.1.1.12
.1.3.6.1.4.1.25049.2.101.1.1.1.1.13
ogAlarmState mandatory
Enumeration
.1.3.6.1.4.1.25049.2.101.1.1.1.1.14
ogAlarmEventId mandatory
.1.3.6.1.4.1.25049.2.101.1.1.1.1.2
ogAlarmName mandatory
OctetString
.1.3.6.1.4.1.25049.2.101.1.1.1.1.3
ogAlarmCheck mandatory
Integer32
.1.3.6.1.4.1.25049.2.101.1.1.1.1.4
ogAlarmInstance mandatory
Integer32
.1.3.6.1.4.1.25049.2.101.1.1.1.1.5
ogAlarmTime mandatory
OctetString
.1.3.6.1.4.1.25049.2.101.1.1.1.1.6
ogAlarmType mandatory
Enumeration
.1.3.6.1.4.1.25049.2.101.1.1.1.1.7
ogAlarmSummary mandatory
OctetString
.1.3.6.1.4.1.25049.2.101.1.1.1.1.8
ogAlarmDevice mandatory
OctetString
.1.3.6.1.4.1.25049.2.101.1.1.1.1.9
.1.3.6.1.4.1.25049.2.102
.1.3.6.1.4.1.25049.2.102.1
.1.3.6.1.4.1.25049.2.102.1.1
.1.3.6.1.4.1.25049.2.102.1.1.1
.1.3.6.1.4.1.25049.2.102.1.1.1.1
.1.3.6.1.4.1.25049.2.103
.1.3.6.1.4.1.25049.2.103.1
.1.3.6.1.4.1.25049.2.103.1.1
.1.3.6.1.4.1.25049.2.103.1.1.1
.1.3.6.1.4.1.25049.2.103.1.1.1.1
.1.3.6.1.4.1.25049.2.104
.1.3.6.1.4.1.25049.2.104.1
.1.3.6.1.4.1.25049.2.104.1.1
.1.3.6.1.4.1.25049.2.104.1.1.1
.1.3.6.1.4.1.25049.2.104.1.1.1.1
.1.3.6.1.4.1.25049.2.105
.1.3.6.1.4.1.25049.2.105.1
.1.3.6.1.4.1.25049.2.105.1.1
.1.3.6.1.4.1.25049.2.105.1.1.1
.1.3.6.1.4.1.25049.2.105.1.1.1.1
.1.3.6.1.4.1.25049.2.106
.1.3.6.1.4.1.25049.2.106.1
.1.3.6.1.4.1.25049.2.106.1.1
.1.3.6.1.4.1.25049.2.106.1.1.1
.1.3.6.1.4.1.25049.2.106.1.1.1.1
.1.3.6.1.4.1.25049.2.107
.1.3.6.1.4.1.25049.2.107.1
.1.3.6.1.4.1.25049.2.107.1.1
.1.3.6.1.4.1.25049.2.107.1.1.1
.1.3.6.1.4.1.25049.2.107.1.1.1.1
.1.3.6.1.4.1.25049.2.108
.1.3.6.1.4.1.25049.2.108.1
.1.3.6.1.4.1.25049.2.108.1.1
.1.3.6.1.4.1.25049.2.108.1.1.1
.1.3.6.1.4.1.25049.2.108.1.1.1.1
.1.3.6.1.4.1.25049.2.109
.1.3.6.1.4.1.25049.2.109.1
.1.3.6.1.4.1.25049.2.109.1.1
.1.3.6.1.4.1.25049.2.109.1.1.1
.1.3.6.1.4.1.25049.2.109.1.1.1.1
.1.3.6.1.4.1.25049.2.110
.1.3.6.1.4.1.25049.2.110.1
.1.3.6.1.4.1.25049.2.110.1.1
.1.3.6.1.4.1.25049.2.110.1.1.1
.1.3.6.1.4.1.25049.2.110.1.1.1.1
.1.3.6.1.4.1.25049.2.111
.1.3.6.1.4.1.25049.2.111.1
.1.3.6.1.4.1.25049.2.111.1.1
.1.3.6.1.4.1.25049.2.111.1.1.1
.1.3.6.1.4.1.25049.2.111.1.1.1.1
.1.3.6.1.4.1.25049.2.112
.1.3.6.1.4.1.25049.2.112.1
.1.3.6.1.4.1.25049.2.112.1.1
.1.3.6.1.4.1.25049.2.112.1.1.1
.1.3.6.1.4.1.25049.2.112.1.1.1.1
.1.3.6.1.4.1.25049.2.113
.1.3.6.1.4.1.25049.2.113.1
.1.3.6.1.4.1.25049.2.113.1.1
.1.3.6.1.4.1.25049.2.113.1.1.1
.1.3.6.1.4.1.25049.2.113.1.1.1.1
.1.3.6.1.4.1.25049.2.114
.1.3.6.1.4.1.25049.2.114.1
.1.3.6.1.4.1.25049.2.114.1.1
.1.3.6.1.4.1.25049.2.114.1.1.1
.1.3.6.1.4.1.25049.2.114.1.1.1.1
.1.3.6.1.4.1.25049.2.115
.1.3.6.1.4.1.25049.2.115.1
.1.3.6.1.4.1.25049.2.115.1.1
.1.3.6.1.4.1.25049.2.115.1.1.1
.1.3.6.1.4.1.25049.2.115.1.1.1.1
Dependencies (3) 3 direct Show tree and compile order Hide dependency details

Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.

Dependency tree
Dependency-first compile order
  1. RFC-1212rfc
  2. RFC-1215rfc
  3. RFC1155-SMIrfc
  4. OGTRAPv2-MIBopengearselected
Notifications / Traps (33)
NameOIDDescription
.1.3.6.1.4.1.25049.0.1
The alert sent when a signal change occurs
.1.3.6.1.4.1.25049.0.10
The alert sent when a DIO signal state changes
.1.3.6.1.4.1.25049.0.11
The notification sent when a power supply voltage alarm occurs
.1.3.6.1.4.1.25049.0.12
The notification sent when a power supply rail current alarm occurs
.1.3.6.1.4.1.25049.0.13
The notification sent when a power supply temperature alarm occurs
.1.3.6.1.4.1.25049.0.14
The notification sent when a UPS alarm occurs
.1.3.6.1.4.1.25049.0.15
The notification sent when a UPS battery alarm occurs
.1.3.6.1.4.1.25049.0.16
The notification sent when a UPS input alarm occurs
.1.3.6.1.4.1.25049.0.17
The notification sent when a UPS output alarm occurs
.1.3.6.1.4.1.25049.0.18
The notification sent when an RPC input alarm occurs
.1.3.6.1.4.1.25049.0.19
The notification sent when an RPC output alarm occurs
.1.3.6.1.4.1.25049.0.2
The alert sent when a pre-defined pattern was
matched text in a consoles serial character stream
.1.3.6.1.4.1.25049.0.20
The notification sent when an RPC outlet alarm occurs
.1.3.6.1.4.1.25049.0.21
The alert sent when a network interface event occurs
.1.3.6.1.4.1.25049.0.22
The notification sent when a cell data alarm occurs
.1.3.6.1.4.1.25049.0.23
The notification sent when a SMS command alarm occurs
.1.3.6.1.4.1.25049.0.24
The notification sent when a cellular signal alarm occurs.
.1.3.6.1.4.1.25049.0.25
The notification sent when an APN change alarm occurs
.1.3.6.1.4.1.25049.0.26
The notification sent when a cell tower change alarm occurs
.1.3.6.1.4.1.25049.0.27
The notification sent when a cell network change alarm occurs
.1.3.6.1.4.1.25049.0.28
A notification sent when a wireless client
connects/disconnects.
.1.3.6.1.4.1.25049.0.29
A notification sent when a wireless client
signal crosses a threshold.
.1.3.6.1.4.1.25049.0.3
The alert sent when a user connection event occurs.
.1.3.6.1.4.1.25049.0.30
A notification sent when a wireless client
associates/disassociates with this AP.
.1.3.6.1.4.1.25049.0.31
A notification sent when a wireless client
fails to authenticate with this AP.
.1.3.6.1.4.1.25049.0.32
A notification sent when a dial-pool health alarm occurs.
.1.3.6.1.4.1.25049.0.33
A notification sent when a custom check alarm occurs.
.1.3.6.1.4.1.25049.0.4
An alarm sent when a Network Host occurs stops or resumes
responding to a ping.
.1.3.6.1.4.1.25049.0.5
An alarm sent when a service on a network host stops or starts
responding.
.1.3.6.1.4.1.25049.0.6
An alarm sent when a user connection to a Network Host occurs
.1.3.6.1.4.1.25049.0.7
An alarm sent when a user connection to web interface occurs
.1.3.6.1.4.1.25049.0.8
The notification sent when a temperature event occurs
.1.3.6.1.4.1.25049.0.9
The notification sent when a humidity event occurs