OA-FRONT-PANEL-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
1
Rows
1
Columns
8
oaFrPanelSlotTable
table.1.3.6.1.4.1.629.1.50.16.20.5.5
·
1 row entry
·
8 columns
Uses the mrv variant from
Command help
/opt/observium/mibs/mrv.
Walk oaFrPanelSlotTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'OA-FRONT-PANEL-MIB' -M '/opt/observium/mibs/mrv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'OA-FRONT-PANEL-MIB::oaFrPanelSlotTable'
Table describes the changable components that can be shown on the Device Front Panel.
.
| Column | Syntax | OID |
|---|---|---|
| oaFrPanelSltShelfIdThe Shelf Number the Slot belongs to. In case of Stand Alone device - always is equal to 1. | Integer32 Constraints: range: 1-16 | .1.3.6.1.4.1.629.1.50.16.20.5.5.1.1 |
| oaFrPanelSltSlotIdThe Slot Id into the corresponding Shelf. | Integer32 Constraints: range: 1-64 | .1.3.6.1.4.1.629.1.50.16.20.5.5.1.2 |
| oaFrPanelSltPortsNumberThe Max. number of the Ports placed in the Slot Front Panel. | Integer32 Constraints: range: 0-255 | .1.3.6.1.4.1.629.1.50.16.20.5.5.1.3 |
| oaFrPanelSltLedsNumberThe Max number of the Objects [LEDs,Ports,Labels,Pictures etc.] that must be drawn on the Slot Front Panel. | Integer32 Constraints: range: 0-255 | .1.3.6.1.4.1.629.1.50.16.20.5.5.1.4 |
| oaFrPanelSltLedsVersionThe Front Panel version. Indicates how to interpret this Table Objects Octet Strings. For example version=1 means that each byte in the Octet String stores the value of the corresponding Port parameter in the Slot. | Integer32 Constraints: range: 1-4294967295 | .1.3.6.1.4.1.629.1.50.16.20.5.5.1.5 |
| oaFrPanelSltLedStatusesThe statuses of all Objects [LEDs,Ports,Labels,Pictures etc.] that must be drawn on the Slot Front Panel. Each byte of the Octet String can store such values: - in case of Colors: 0 - [unknown], 1 - Ligh… | OctetString Constraints: range: 0-255 | .1.3.6.1.4.1.629.1.50.16.20.5.5.1.6 |
| oaFrPanelSltPrtsConnectorThe Connector Types of the Ports placed in the Slot. Each byte of the Octet String can store such values: other - 1 - Unknown type of connector, static- 2 - Not Changeable (fix) type of connector, gbic - 3 - GBIC type… | OctetString Constraints: range: 0-255 | .1.3.6.1.4.1.629.1.50.16.20.5.5.1.7 |
| oaFrPanelSltPrtsSubConnectorThe Connector Physical Sub Types of the Ports placed in the Slot. Each byte of the Octet String can store such values: other - 1 - Unknown or N/A Connector's connectivity Type, rj45 - 2 - Copper RJ45, sc - 3 - Regu… | OctetString Constraints: range: 0-255 | .1.3.6.1.4.1.629.1.50.16.20.5.5.1.8 |