.1.3.6.1.4.1.17409.1.1.1
·
1 row entry
·
8 columns
Uses the vialite variant from
Command help
/opt/observium/mibs/vialite.
Walk analogPropertyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NSCRTV-OSW' -M '/opt/observium/mibs/vialite:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NSCRTV-OSW::analogPropertyTable'
Simulation parameters attribute table.
Attribute Table simulation parameters head.OID purpose as a table index, the coding method is 'length + OID.' OID before two members of the '130' is based on '1' and '3' respectively coding, and not ordinary OID encodin…
Indexes
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
analogParameterOIDmandatory
index
|
ObjectIdentifier | .1.3.6.1.4.1.17409.1.1.1.1.1 |
||||||||||
|
alarmEnablemandatory
Alarm enable control byte, the corresponding position for the'1 'that allow alarm,'0' a ban warning
Bit 0: Alarm enable low Bit 1: Alarm enable low Bit 2: Alarm enable high Bit 3: Alarm enable high Bit 4 ~ 7 reservation… |
OctetStringr/w Constraints: range: 1-1 |
.1.3.6.1.4.1.17409.1.1.1.1.2 |
||||||||||
|
analogAlarmStatemandatory
The parameters of the current state of alarm.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.17409.1.1.1.1.3 |
||||||||||
|
analogAlarmHIHImandatory
The parameters of the current state of alarm.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.17409.1.1.1.1.4 |
||||||||||
|
analogAlarmHImandatory
HI high alarm threshold value. This object should be stored in non-volatile memory
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.17409.1.1.1.1.5 |
||||||||||
|
analogAlarmLOmandatory
LO low alarm threshold value. This object should be stored in nonvolatile memory
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.17409.1.1.1.1.6 |
||||||||||
|
analogAlarmLOLOmandatory
Alarm LOLO very low threshold value. This object should be stored in nonvolatile memory.
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.17409.1.1.1.1.7 |
||||||||||
|
analogAlarmDeadbandmandatory
Dead-alarm threshold value. After the warning, parameter values should be restored to the alarm threshold and alarm threshold and the difference between the absolute value greater than the value of dead zone, the alarm …
|
Integer32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.17409.1.1.1.1.8 |
.1.3.6.1.4.1.17409.1.1.2
·
1 row entry
·
4 columns
Uses the vialite variant from
Command help
/opt/observium/mibs/vialite.
Walk discretePropertyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NSCRTV-OSW' -M '/opt/observium/mibs/vialite:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NSCRTV-OSW::discretePropertyTable'
Discrete Attribute Table
Attribute Table discrete head. OID coding methods with simulation attribute table.
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
discreteParameterOIDmandatory
Attribute Table discrete index 1: Parameters OID
|
ObjectIdentifier | .1.3.6.1.4.1.17409.1.1.2.1.1 |
||||||
|
discreteAlarmValuemandatory
Attribute Table discrete index 2: parameter values.When the equipment value of this parameter values, and so will be dealt with a warning
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.17409.1.1.2.1.2 |
||||||
|
discreteAlarmEnablemandatory
When the alarm so that it can open the (2 or 3), this parameter allows for alarm processin
If the alarm so that it can shut down (1), alarm processing will be carried out. This object default values for the disable (1).… |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.17409.1.1.2.1.3 |
||||||
|
discreteAlarmStatemandatory
The parameters of the current state of alarm
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.17409.1.1.2.1.4 |
.1.3.6.1.4.1.17409.1.1.3
·
1 row entry
·
3 columns
Uses the vialite variant from
Command help
/opt/observium/mibs/vialite.
Walk currentAlarmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NSCRTV-OSW' -M '/opt/observium/mibs/vialite:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NSCRTV-OSW::currentAlarmTable'
The current alarm table.
The current warning Table Head. OID coding methods with simulation attribute table
Indexes
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
currentAlarmOIDmandatory
NE, currently in a state of alarm parameters OID Index, and the alarm in the table attribute parameters OID counterparts.
|
ObjectIdentifier | .1.3.6.1.4.1.17409.1.1.3.1.1 |
||||||||||||
|
currentAlarmStatemandatory
Warning parameters of the current state of alarm
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.17409.1.1.3.1.2 |
||||||||||||
|
currentAlarmValuemandatory
Alarm parameter values.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.17409.1.1.3.1.3 |
.1.3.6.1.4.1.17409.1.2.3
·
1 row entry
·
2 columns
Uses the vialite variant from
Command help
/opt/observium/mibs/vialite.
Walk alarmLogTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NSCRTV-OSW' -M '/opt/observium/mibs/vialite:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NSCRTV-OSW::alarmLogTable'
Alarm record form, at least support 16 record. Each table in the registration of a new record, the management agent (transponder) managers should send traps news
Alarm Sheet Head
Indexes
| Column | Syntax | OID |
|---|---|---|
|
alarmLogIndexmandatory
The only logo Alarm Index recorded a record in the table, the index value increased from 1 start of each new record, plus 1 until 32767, under a record index of the re-starts at 1. Acting under the management of storage…
|
Integer32 Constraints: range: 1-32767 |
.1.3.6.1.4.1.17409.1.2.3.1.1 |
|
alarmLogInformationmandatory
Alarm record information, multi-byte strings, defined as follows:
Byte 1 ~ 4: Alarm in time (POSIX format, the previous maximum byte) Byte 5: Alarm types (enumeration, definitions????) Byte 6: Alarm value after commonNe… |
OctetString Constraints: range: 17-255 |
.1.3.6.1.4.1.17409.1.2.3.1.2 |
.1.3.6.1.4.1.17409.1.3.2.1.1.3
·
1 row entry
·
2 columns
Uses the vialite variant from
Command help
/opt/observium/mibs/vialite.
Walk commonMulticastAddressTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NSCRTV-OSW' -M '/opt/observium/mibs/vialite:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NSCRTV-OSW::commonMulticastAddressTable'
Multicast addresses Table, the value of this object should be stored in nonvolatile memory.
Multicast addresses head table.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
commonMulticastAddressIndexmandatory
Multicast addresses head table.
|
Integer32 Constraints: range: 1-255 |
.1.3.6.1.4.1.17409.1.3.2.1.1.3.1.1 |
|
commonMulticastAddressNumbermandatory
Multicast address, I / G-1 effective.
|
OctetStringr/w Constraints: range: 6-6 |
.1.3.6.1.4.1.17409.1.3.2.1.1.3.1.2 |
.1.3.6.1.4.1.17409.1.3.3.1.7
·
1 row entry
·
4 columns
Uses the vialite variant from
Command help
/opt/observium/mibs/vialite.
Walk commonAgentTrapTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NSCRTV-OSW' -M '/opt/observium/mibs/vialite:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NSCRTV-OSW::commonAgentTrapTable'
Acting Information Table TRAP
Acting Head TRAP Information Table
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
commonAgentTrapIndexmandatory
TRAP Table Index
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.17409.1.3.3.1.7.1.1 |
||||
|
commonAgentTrapIPmandatory
When the purpose of the TRAP host's IP address
|
RFC1155-SMIIpAddressr/w Type Constraints: range: 4 |
.1.3.6.1.4.1.17409.1.3.3.1.7.1.2 |
||||
|
commonAgentTrapCommunitymandatory
Send the Community string TRAP
|
SNMPv2-TCDisplayStringr/w Constraints: range: 0-64Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.17409.1.3.3.1.7.1.3 |
||||
|
commonAgentTrapStatusmandatory
It said that the opening of TRAP
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.17409.1.3.3.1.7.1.4 |
.1.3.6.1.4.1.17409.1.3.3.2.2
·
1 row entry
·
19 columns
Uses the vialite variant from
Command help
/opt/observium/mibs/vialite.
Walk commonDeviceInfoTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NSCRTV-OSW' -M '/opt/observium/mibs/vialite:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NSCRTV-OSW::commonDeviceInfoTable'
Acting is currently public information management equipment list.
Acting is currently public information management equipment list Table Head.
Indexes
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
commonDeviceSlotmandatory
Acting is currently under the management of the equipment list of public information table index.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.17409.1.3.3.2.2.1.1 |
||||||||||
|
commonDevicesIDmandatory
Designated equipment manufacturers logo
|
OctetString Constraints: range: 0-40 |
.1.3.6.1.4.1.17409.1.3.3.2.2.1.2 |
||||||||||
|
commonDeviceVendormandatory
Equipment manufacturers
|
SNMPv2-TCDisplayString Constraints: range: 0-255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.17409.1.3.3.2.2.1.3 |
||||||||||
|
commonDeviceModelNumbermandatory
Equipment models.
|
SNMPv2-TCDisplayString Constraints: range: 0-255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.17409.1.3.3.2.2.1.4 |
||||||||||
|
commonDeviceSerialNumbermandatory
The string of equipment.
|
SNMPv2-TCDisplayString Constraints: range: 0-255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.17409.1.3.3.2.2.1.5 |
||||||||||
|
commonDeviceVendorInfooptional
Equipment suppliers of other special designated information
|
SNMPv2-TCDisplayString Constraints: range: 0-255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.17409.1.3.3.2.2.1.6 |
||||||||||
|
commonDeviceStatusmandatory
Bit 0: RSVD0
Bit 1: RSVD1 Bit 2: RSVD2 Bit 3: MAJOR ALARMS Bit 4: MINOR ALARMS Bit 5: RSVD5 Bit 6: RSVD6 Bit 7: RSVD7 |
OctetString Constraints: range: 1-1 |
.1.3.6.1.4.1.17409.1.3.3.2.2.1.7 |
||||||||||
|
commonDeviceResetmandatory
Write'1 'will be reset equipment, other values will be written into the non-functional. Reading this object return value'1 ', the equipment had no effect.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.17409.1.3.3.2.2.1.8 |
||||||||||
|
commonDeviceAlarmDetectionControlmandatory
This object used to control equipment alarm detection.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.17409.1.3.3.2.2.1.9 |
||||||||||
|
commonDeviceMACAddressmandatory
Equipment MAC address
|
.1.3.6.1.4.1.17409.1.3.3.2.2.1.10 |
|||||||||||
|
commonDeviceTamperStatusoptional
Report of the safety switch equipment (such as whether to open up the lid) state that this object is called discrete attributes of a corresponding entry in the table. Intact that normal, compromised expressed alarm.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.17409.1.3.3.2.2.1.11 |
||||||||||
|
commonDeviceInternalTemperatureoptional
Equipment Room (machine) temperature, units degrees Celsius. This request object attribute in a corresponding entry in the table
|
Integer32 Constraints: range: -128-127 |
.1.3.6.1.4.1.17409.1.3.3.2.2.1.12 |
||||||||||
|
commonDeviceResetCausemandatory
Equipment that the reasons for the recent reduction
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.17409.1.3.3.2.2.1.13 |
||||||||||
|
commonDeviceCraftStatusmandatory
This object interface that local equipment (such as RS232 or RS485 interface) state.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.17409.1.3.3.2.2.1.14 |
||||||||||
|
commonDevicesOIDmandatory
Goals identifier string, point to a concrete realization of the equipment
|
ObjectIdentifier | .1.3.6.1.4.1.17409.1.3.3.2.2.1.15 |
||||||||||
|
commonDeviceAcctoptional
Equipment that the accumulated work time, units of s
|
.1.3.6.1.4.1.17409.1.3.3.2.2.1.16 |
|||||||||||
|
commonDeviceNamemandatory
Equipment name
|
SNMPv2-TCDisplayString Constraints: range: 0-255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.17409.1.3.3.2.2.1.17 |
||||||||||
|
commonDeviceMFDmandatory
Equipment manufacturing date.
|
SNMPv2-TCDisplayString Constraints: range: 10-10Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.17409.1.3.3.2.2.1.18 |
||||||||||
|
commonDeviceFWmandatory
Equipment firmware information
|
SNMPv2-TCDisplayString Constraints: range: 0-255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.17409.1.3.3.2.2.1.19 |
.1.3.6.1.4.1.17409.1.15.4
·
1 row entry
·
5 columns
Uses the vialite variant from
Command help
/opt/observium/mibs/vialite.
Walk oswChannelTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NSCRTV-OSW' -M '/opt/observium/mibs/vialite:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NSCRTV-OSW::oswChannelTable'
Optical Switch Information Table
Optical Switch Information Table Head
Indexes
| Column | Syntax | OID |
|---|---|---|
|
oswIndexmandatory |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.17409.1.15.4.1.1 |
|
oswInputAmandatory
The input optical power of route A, unit in 0.1 dBm, this object require entry register in the attribute MIB.
|
Integer32 Constraints: range: -128-127 |
.1.3.6.1.4.1.17409.1.15.4.1.2 |
|
oswInputBmandatory
The input optical power of route B, unit in 0.1 dBm, this object require entry register in the attribute MIB.
|
Integer32 Constraints: range: -128-127 |
.1.3.6.1.4.1.17409.1.15.4.1.3 |
|
oswOutput1mandatory
The input optical power of route 1, unit in 0.1 dBm, this object require entry register in the attribute MIB.
|
Integer32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.17409.1.15.4.1.4 |
|
oswOutput2mandatory
The input optical power of route 2, unit in 0.1 dBm, this object require entry register in the attribute MIB.
|
Integer32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.17409.1.15.4.1.5 |
.1.3.6.1.4.1.17409.1.15.7
·
1 row entry
·
4 columns
Uses the vialite variant from
Command help
/opt/observium/mibs/vialite.
Walk oswDCPowerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NSCRTV-OSW' -M '/opt/observium/mibs/vialite:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NSCRTV-OSW::oswDCPowerTable'
DC Power Information Table
DC Power Information Table Head
Indexes
| Column | Syntax | OID |
|---|---|---|
|
oswDCPowerIndexmandatory
DC Power Index, table oswDCPowerTable index
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.17409.1.15.7.1.1 |
|
oswDCPowerVoltagemandatory
Power supply voltage, unit in 0.1 V, this object require entry register in the attribute MIB.
|
Integer32 Constraints: range: -32768-32767 |
.1.3.6.1.4.1.17409.1.15.7.1.2 |
|
oswDCPowerCurrentmandatory
Power supply current, unit in 0.1 A, this object require entry register in the attribute MIB.
|
Integer32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.17409.1.15.7.1.3 |
|
oswDCPowerNamemandatory
Mark Power supply name, for example: +5 V DC power supply.
This field value regulated by the user, it should be marked with the number of the power supply voltage and distinguish the multi-power supplies at least. When … |
SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.17409.1.15.7.1.4 |