NMS-EPON-OLT-PERFORMANCE Table View

Table-centric layout grouping table, row, and column objects.

Tables
2
Rows
2
Columns
30
.1.3.6.1.4.1.3320.101.201.1.1 · 1 row entry · 25 columns
Uses the bdcom variant from /opt/observium/mibs/bdcom.
Command help
Walk onuPerformParameterAlarmsSetTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NMS-EPON-OLT-PERFORMANCE' -M '/opt/observium/mibs/bdcom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NMS-EPON-OLT-PERFORMANCE::onuPerformParameterAlarmsSetTable'
Description.
onuPerformParameterAlarmsSetEntry row .1.3.6.1.4.1.3320.101.201.1.1.1
Description.
Indexes
Column Syntax OID
llidIfIndexmandatory
Index of LLID interface.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3320.101.201.1.1.1.1
Enable or disable the alarm of CPU usage. 1-enable, 2-disable. Default is disable.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.3320.101.201.1.1.1.2
The upper threshold of CPU usage alarm. The unit is 1%. The range is 1-100. Default is 100.
Integer32r/w
Constraints:
range: 1-100
.1.3.6.1.4.1.3320.101.201.1.1.1.3
The upper threshold of CPU usage alarm cleared. The range is 1-100. Default is 100.
Integer32r/w
Constraints:
range: 1-100
.1.3.6.1.4.1.3320.101.201.1.1.1.4
The row status of CPU usage alarm .
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3320.101.201.1.1.1.5
Enable or disable the alarm of RAM usage. 1-enable, 2-disable. Default is disable.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.3320.101.201.1.1.1.6
The upper threshold of RAM usage alarm. The unit is 1%. The range is 1-100. Default is 100.
Integer32r/w
Constraints:
range: 1-100
.1.3.6.1.4.1.3320.101.201.1.1.1.7
The upper threshold of RAM usage alarm cleared. The range is 1-100. Default is 100.
Integer32r/w
Constraints:
range: 1-100
.1.3.6.1.4.1.3320.101.201.1.1.1.8
The row status of RAM usage alarm .
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3320.101.201.1.1.1.9
Enable or disable the alarm of PON high temperature. 1-enable, 2-disable. Default is disable.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.3320.101.201.1.1.1.10
The upper threshold of temperature alarm. The unit is 0.1 degree. The range is -1280-1280. Default is 1280.
Integer32r/w
Constraints:
range: -1280-1280
.1.3.6.1.4.1.3320.101.201.1.1.1.11
The upper threshold temperature alarm cleared. The unit is 0.1 degree. The range is -1280-1280. Default is 1280.
Integer32r/w
Constraints:
range: -1280-1280
.1.3.6.1.4.1.3320.101.201.1.1.1.12
The row status of temperature upper alarm.
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3320.101.201.1.1.1.13
Enable or disable the alarm of PON low temperature. 1-enable, 2-disable. Default is disable.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.3320.101.201.1.1.1.14
The low threshold of temperature alarm. The unit is 0.1 degree. The range is -1280-1280. Default is -1280.
Integer32r/w
Constraints:
range: -1280-1280
.1.3.6.1.4.1.3320.101.201.1.1.1.15
The low threshold temperature alarm cleared. The unit is 0.1 degree. The range is -1280-1280. Default is -1280.
Integer32r/w
Constraints:
range: -1280-1280
.1.3.6.1.4.1.3320.101.201.1.1.1.16
The row status of temperature low alarm.
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3320.101.201.1.1.1.17
Enable or disable the alarm of PON high voltage. 1-enable, 2-disable. Default is disable.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.3320.101.201.1.1.1.18
The upper threshold of voltage alarm. The unit is 0.1V. The range is 0-65. Default is 65.
Integer32r/w
Constraints:
range: 0-65
.1.3.6.1.4.1.3320.101.201.1.1.1.19
The upper threshold voltage alarm cleared. The unit is 0.1V. The range is 0-65. Default is 65.
Integer32r/w
Constraints:
range: 0-65
.1.3.6.1.4.1.3320.101.201.1.1.1.20
The row status of voltage upper alarm.
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3320.101.201.1.1.1.21
Enable or disable the alarm of PON low voltage. 1-enable, 2-disable. Default is disable.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.3320.101.201.1.1.1.22
The low threshold of voltage alarm. The unit is 0.1V. The range is 0-65. Default is 0.
Integer32r/w
Constraints:
range: 0-65
.1.3.6.1.4.1.3320.101.201.1.1.1.23
The low threshold voltage alarm cleared. The unit is 0.1V. The range is 0-65. Default is 0.
Integer32r/w
Constraints:
range: 0-65
.1.3.6.1.4.1.3320.101.201.1.1.1.24
The row status of voltage low alarm.
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3320.101.201.1.1.1.25

onuPerformParameterTable

table mandatory
.1.3.6.1.4.1.3320.101.201.1.2 · 1 row entry · 5 columns
Uses the bdcom variant from /opt/observium/mibs/bdcom.
Command help
Walk onuPerformParameterTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NMS-EPON-OLT-PERFORMANCE' -M '/opt/observium/mibs/bdcom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NMS-EPON-OLT-PERFORMANCE::onuPerformParameterTable'
Description.
onuPerformParameterEntry row .1.3.6.1.4.1.3320.101.201.1.2.1
Description.
Indexes
Column Syntax OID
ifIndexmandatory
Index of LLID interface.
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3320.101.201.1.2.1.1
cpuUsagemandatory
CPU usage . The unit is 1%. The range is 1-100. Default is 0.
Integer32r/w
Constraints:
range: 0-100
.1.3.6.1.4.1.3320.101.201.1.2.1.2
ramUsagemandatory
RAM usage. The unit is 1%. The range is 1-100. Default is 0.
Integer32r/w
Constraints:
range: 0-100
.1.3.6.1.4.1.3320.101.201.1.2.1.3
temperaturemandatory
Temperature.The unit is 0.1 degree. The range is -1280-1280. Default is 0.
Integer32r/w
Constraints:
range: -1280-1280
.1.3.6.1.4.1.3320.101.201.1.2.1.4
voltagemandatory
Voltage.The unit is 0.1V. The range is 0-65. Default is 0.
Integer32r/w
Constraints:
range: 0-65
.1.3.6.1.4.1.3320.101.201.1.2.1.5