NEWTEC-TSANALYSER-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
3
Rows
3
Columns
21
.1.3.6.1.4.1.5835.5.2.1400.1.4 · 1 row entry · 6 columns
Uses the newtec variant from /opt/observium/mibs/newtec.
Command help
Walk ntcTsAnlyPidTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NEWTEC-TSANALYSER-MIB' -M '/opt/observium/mibs/newtec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NEWTEC-TSANALYSER-MIB::ntcTsAnlyPidTable'
A table containing all detected PID's of the incoming traffic stream with
corresponding measurements.
ntcTsAnlyPidEntry row .1.3.6.1.4.1.5835.5.2.1400.1.4.1
A conceptual row of the ntcTsAnlyPidTable.
Indexes
Column Syntax OID
PID
Unsigned32
Constraints:
range: 0-8190
.1.3.6.1.4.1.5835.5.2.1400.1.4.1.1
PID Type
Enumeration
Enumerated Values:
0others
1video
2audio
3privateSection
4pesPrivate
5mheg
6dsmCc
7h2221
8mpe
9auxiliary
10slOrFlexMux
11sdp
12metadata
13ipmp
14userPrivate
15pat
16cat
17tsdt
18nitOrSt
19sdtOrBatOrSt
20eitOrStCit
21rstOrSt
22tdtOrTotOrSt
23netwSync
24rnt
25inband
26measurement
27dit
28sit
29null
30othersOrGhost
31pmt
32visual
33srm
34ecm
35emm
.1.3.6.1.4.1.5835.5.2.1400.1.4.1.2
PID Rate for a specific stream.
bpsSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5835.5.2.1400.1.4.1.3
Continuity Count Error
Enumeration
Enumerated Values:
0off
1on
.1.3.6.1.4.1.5835.5.2.1400.1.4.1.4
Transport Error
Enumeration
Enumerated Values:
0off
1on
.1.3.6.1.4.1.5835.5.2.1400.1.4.1.5
Indicates the number of packets with a continuity count error.
packetsSNMPv2-SMICounter64
Type Constraints:
range: 0..18446744073709551615
.1.3.6.1.4.1.5835.5.2.1400.1.4.1.6
.1.3.6.1.4.1.5835.5.2.1400.1.5 · 1 row entry · 10 columns
Uses the newtec variant from /opt/observium/mibs/newtec.
Command help
Walk ntcTsAnlyPcrPidTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NEWTEC-TSANALYSER-MIB' -M '/opt/observium/mibs/newtec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NEWTEC-TSANALYSER-MIB::ntcTsAnlyPcrPidTable'
A table of PCR PID's with detailled time measurements.
ntcTsAnlyPcrPidEntry row .1.3.6.1.4.1.5835.5.2.1400.1.5.1
A conceptual row of the ntcTsAnlyPcrPidTable.
Column Syntax OID
PID
Unsigned32
Constraints:
range: 0-8190
.1.3.6.1.4.1.5835.5.2.1400.1.5.1.1
Measured interval time (in milliseconds) between 2 PCR packets.
msUnsigned32
Constraints:
range: 0-9999999
.1.3.6.1.4.1.5835.5.2.1400.1.5.1.2
PCR Repetition Error is raised when the spacing between two consecutive PCR
values is more than 40ms. The condition can occur when PCR packets get lost or
when PCR packets are not present at a sufficient rate.
Enumeration
Enumerated Values:
0off
1on
.1.3.6.1.4.1.5835.5.2.1400.1.5.1.3
The PCR Accuracy error is raised when the PCR accuracy exceeds +/- 500nsec.
The definition of the alarm is taken from TR101290.
Enumeration
Enumerated Values:
0off
1on
.1.3.6.1.4.1.5835.5.2.1400.1.5.1.4
Minimum value of PCR_AC (nanoseconds) over the last second.
nsInteger32
Constraints:
range: -9999999-9999999
.1.3.6.1.4.1.5835.5.2.1400.1.5.1.5
Max Jitter PCR_AC (nanoseconds) measured over the last second.
nsInteger32
Constraints:
range: -9999999-9999999
.1.3.6.1.4.1.5835.5.2.1400.1.5.1.6
The minimum measured PCR_AC value (in nanoseconds) computed since the last
reset.
nsInteger32
Constraints:
range: -9999999-9999999
.1.3.6.1.4.1.5835.5.2.1400.1.5.1.7
The maximum measured PCR_AC value (in nanoseconds) computed since the last
reset.
nsInteger32
Constraints:
range: -9999999-9999999
.1.3.6.1.4.1.5835.5.2.1400.1.5.1.8
Rate Offset in PPM of the inband clock companed to the local clock. (ASI:
local clock, TS over IP: configured bitrate)
ppmSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5835.5.2.1400.1.5.1.9
PCR Rate (Mb/s) calculated by using the inband PCR timing information.
bpsSNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5835.5.2.1400.1.5.1.10
.1.3.6.1.4.1.5835.5.2.1400.1.7 · 1 row entry · 5 columns
Uses the newtec variant from /opt/observium/mibs/newtec.
Command help
Walk ntcTsAnlyEPidTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NEWTEC-TSANALYSER-MIB' -M '/opt/observium/mibs/newtec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NEWTEC-TSANALYSER-MIB::ntcTsAnlyEPidTable'
Table which contains PIDs on which an error has been detected.
ntcTsAnlyEPidEntry row .1.3.6.1.4.1.5835.5.2.1400.1.7.1
A conceptual row of the ntcTsAnlyEPidTable.
Column Syntax OID
PID
Unsigned32
Constraints:
range: 0-8190
.1.3.6.1.4.1.5835.5.2.1400.1.7.1.1
PID Type
Enumeration
Enumerated Values:
0others
1video
2audio
3privateSection
4pesPrivate
5mheg
6dsmCc
7h2221
8mpe
9auxiliary
10slOrFlexMux
11sdp
12metadata
13ipmp
14userPrivate
15pat
16cat
17tsdt
18nitOrSt
19sdtOrBatOrSt
20eitOrStCit
21rstOrSt
22tdtOrTotOrSt
23netwSync
24rnt
25inband
26measurement
27dit
28sit
29null
30othersOrGhost
31pmt
32visual
33srm
34ecm
35emm
.1.3.6.1.4.1.5835.5.2.1400.1.7.1.2
Indicates the number of packets with a continuity count error.
packetsSNMPv2-SMICounter64
Type Constraints:
range: 0..18446744073709551615
.1.3.6.1.4.1.5835.5.2.1400.1.7.1.3
Continuity Count Error
Enumeration
Enumerated Values:
0off
1on
.1.3.6.1.4.1.5835.5.2.1400.1.7.1.4
Transport Error
Enumeration
Enumerated Values:
0off
1on
.1.3.6.1.4.1.5835.5.2.1400.1.7.1.5