panelTable
table.1.3.6.1.4.1.6302.4.1.2.2.1
·
1 row entry
·
9 columns
Uses the vertiv variant from
Command help
/opt/observium/mibs/vertiv.
Walk panelTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NETSURE-DISTRIB-MIB' -M '/opt/observium/mibs/vertiv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NETSURE-DISTRIB-MIB::panelTable'
Panel Table.
Panel Table Entry.
Indexes
No indexes recorded
| Column | Syntax | OID | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| panelIndexAutomatically generated index object. | Integer32 | .1.3.6.1.4.1.6302.4.1.2.2.1.1.1 | ||||||||||||||||
| panelPositionA through H (assigned by the controller),a(0) or b(1) or c(2) or d(3) or e(4) or f(5) or g(6) or h(7) | PanelPositionString Type Values:
| .1.3.6.1.4.1.6302.4.1.2.2.1.1.2 | ||||||||||||||||
| panelNameUser-provided, 32 characters | SNMPv2-TCDisplayStringr/w Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.6302.4.1.2.2.1.1.3 | ||||||||||||||||
| panelEnabledEnabled (0) or Disabled (1) | EnableStater/w Type Values:
| .1.3.6.1.4.1.6302.4.1.2.2.1.1.4 | ||||||||||||||||
| panelTypeStandard (0) or Advanced (1) | PanelTypeOptionsr/w Type Values:
| .1.3.6.1.4.1.6302.4.1.2.2.1.1.5 | ||||||||||||||||
| panelFeedFeedID of Panel | Integer32r/w | .1.3.6.1.4.1.6302.4.1.2.2.1.1.6 | ||||||||||||||||
| panelClearAccumulatedValuesUsed to clear accumulated values for all distribution devices in this this panel Write 1 to clear values | ClearDataOptionsr/w Type Values:
| .1.3.6.1.4.1.6302.4.1.2.2.1.1.7 | ||||||||||||||||
| panelDistributionMeasurementTypeHall (0) or Shunt (1) (advanced panels only) | MeasurementTyper/w Type Values:
| .1.3.6.1.4.1.6302.4.1.2.2.1.1.8 | ||||||||||||||||
| panelNumberDistributionElementsNumber of distributions points in this panel | Integer32r/w | .1.3.6.1.4.1.6302.4.1.2.2.1.1.9 |
feedTable
table.1.3.6.1.4.1.6302.4.1.2.3.1
·
1 row entry
·
24 columns
Uses the vertiv variant from
Command help
/opt/observium/mibs/vertiv.
Walk feedTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NETSURE-DISTRIB-MIB' -M '/opt/observium/mibs/vertiv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NETSURE-DISTRIB-MIB::feedTable'
Feed Table.
Feed Table Entry.
Indexes
No indexes recorded
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
| feedIndexAutomatically generated index object. | Integer32 | .1.3.6.1.4.1.6302.4.1.2.3.1.1.1 | ||||
| feedID1 through 8 (assigned by the controller) | Integer32 | .1.3.6.1.4.1.6302.4.1.2.3.1.1.2 | ||||
| feedNameUser-provided, 32 characters | SNMPv2-TCDisplayStringr/w Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.6302.4.1.2.3.1.1.3 | ||||
| feedOutputVoltageOutput voltage in mV | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.3.1.1.4 | ||||
| feedTotalCurrentOutput current in mA | SNMPv2-SMIInteger32 Constraints: range: 1-268386303 | .1.3.6.1.4.1.6302.4.1.2.3.1.1.5 | ||||
| feedTotalPowerOutput power in Watts | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.3.1.1.6 | ||||
| feedPeakPowerLast24hrsMaximum output power over the past 24 hours in Watts | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.3.1.1.7 | ||||
| feedPeakPowerLastWeekMaximum output power over the past 7 days in Watts | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.3.1.1.8 | ||||
| feedPeakPowerLastMonthMaximum output power over the past 30 days in Watts | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.3.1.1.9 | ||||
| feedTotalEnergyLast24hrsTotal output energy over the past 24 hours in 0.001 kWh | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.3.1.1.10 | ||||
| feedTotalEnergyLastWeekTotal output energy over the past 7 days in 0.001 kWh | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.3.1.1.11 | ||||
| feedTotalEnergyLastMonthTotal output energy over the past 30 days in 0.001 kWh | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.3.1.1.12 | ||||
| feedTotalEnergyTotal/cumulative output energy since last reset, stored as 0.001 kWh | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.3.1.1.13 | ||||
| feedFACBStatusFA-CB Status 0=ok 1=alarm | FACBState Type Values:
| .1.3.6.1.4.1.6302.4.1.2.3.1.1.14 | ||||
| feedClearAccumulatedValuesUsed to clear accumulated values in the feed Write 1 to clear values | ClearDataOptionsr/w Type Values:
| .1.3.6.1.4.1.6302.4.1.2.3.1.1.15 | ||||
| feedOverVoltage1Threshold for over-voltage alarm 1 in mV | SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.3.1.1.16 | ||||
| feedOverVoltage2Threshold for over-voltage alarm 2 in mV | SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.3.1.1.17 | ||||
| feedUnderVoltage1Threshold for the low voltage alarm 1 in mV | SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.3.1.1.18 | ||||
| feedUnderVoltage2Threshold for the low voltage alarm 2 in mV | SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.3.1.1.19 | ||||
| feedCurrentBreakerSizeRating of the fuse/CB in Amps | SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.3.1.1.20 | ||||
| feedCurrent1LimitThreshold for high current alarm in 0.001 % | SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.3.1.1.21 | ||||
| feedCurrent2LimitThreshold for very high current alarm in 0.001 % | SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.3.1.1.22 | ||||
| feedShuntVoltageShunt voltage rating in mV | SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.3.1.1.23 | ||||
| feedShuntCurrentShunt current rating in mA | SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.3.1.1.24 |
deviceTable
table.1.3.6.1.4.1.6302.4.1.2.4.1
·
1 row entry
·
20 columns
Uses the vertiv variant from
Command help
/opt/observium/mibs/vertiv.
Walk deviceTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NETSURE-DISTRIB-MIB' -M '/opt/observium/mibs/vertiv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NETSURE-DISTRIB-MIB::deviceTable'
Device Table.
Device Table Entry.
Indexes
No indexes recorded
| Column | Syntax | OID | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| deviceIndexAutomatically generated index object | Integer32 | .1.3.6.1.4.1.6302.4.1.2.4.1.1.1 | ||||||||||||||||
| devicePanelThe panel containing this device (A=1, B=2, etc.). | PanelPositionString Type Values:
| .1.3.6.1.4.1.6302.4.1.2.4.1.1.2 | ||||||||||||||||
| deviceIDThe distribution device's ID/position | Integer32 | .1.3.6.1.4.1.6302.4.1.2.4.1.1.3 | ||||||||||||||||
| deviceNameUser-provided, 32 characters | SNMPv2-TCDisplayStringr/w Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.6302.4.1.2.4.1.1.4 | ||||||||||||||||
| deviceExistsUsed (0) or not Used (1) | EnableStater/w Type Values:
| .1.3.6.1.4.1.6302.4.1.2.4.1.1.5 | ||||||||||||||||
| deviceTotalCurrentTotal output current in mA | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.4.1.1.6 | ||||||||||||||||
| deviceTotalPowerTotal output power in Watts | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.4.1.1.7 | ||||||||||||||||
| devicePeakPowerLast24hrsMaximum output power over the past 24 hours in Watts | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.4.1.1.8 | ||||||||||||||||
| devicePeakPowerLastWeekMaximum output power over the past 7 days in Watts | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.4.1.1.9 | ||||||||||||||||
| devicePeakPowerLastMonthMaximum output power over the past 30 days in Watts | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.4.1.1.10 | ||||||||||||||||
| deviceTotalEnergyLast24hrsTotal output power over the past 24 hours in 0.001 kWh | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.4.1.1.11 | ||||||||||||||||
| deviceTotalEnergyLastWeekTotal output power over the past 7 days in 0.001 kWh | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.4.1.1.12 | ||||||||||||||||
| deviceTotalEnergyLastMonthTotal output power over the past 30 days in 0.001 kWh | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.4.1.1.13 | ||||||||||||||||
| deviceTotalEnergyTotal/cumulative output energy since last reset, stored as 0.001 kWh | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.4.1.1.14 | ||||||||||||||||
| deviceFACBStatusFA-CB Status 0=ok 1=alarm | FACBState Type Values:
| .1.3.6.1.4.1.6302.4.1.2.4.1.1.15 | ||||||||||||||||
| deviceClearAccumulatedValuesUsed to clear accumulated values Write 1 to clear values | ClearDataOptionsr/w Type Values:
| .1.3.6.1.4.1.6302.4.1.2.4.1.1.16 | ||||||||||||||||
| deviceCurrentBreakerSizeRating of the fuse/CB in mA | SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.4.1.1.17 | ||||||||||||||||
| deviceHighCurrentLimit1Threshold for high current alarm in 0.001 % | SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.4.1.1.18 | ||||||||||||||||
| deviceHighCurrentLimit2Threshold for very high current alarm in 0.001 % | SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.4.1.1.19 | ||||||||||||||||
| deviceNumberofBreakerPositionsNumber of breaker positions (1 to 3). The positions are contiguous. Contiguous breaker positions are treated as one distribution device. one=(0) or two=(1) or three=(2) or four=(3). | DeviceNumberofBreakerr/w Type Values:
| .1.3.6.1.4.1.6302.4.1.2.4.1.1.20 |
loadTable
table.1.3.6.1.4.1.6302.4.1.2.5.1
·
1 row entry
·
15 columns
Uses the vertiv variant from
Command help
/opt/observium/mibs/vertiv.
Walk loadTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NETSURE-DISTRIB-MIB' -M '/opt/observium/mibs/vertiv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NETSURE-DISTRIB-MIB::loadTable'
Load Table.
Load Table Entry.
Indexes
No indexes recorded
| Column | Syntax | OID | ||
|---|---|---|---|---|
| loadIndexAutomatically generated index object. | Integer32 | .1.3.6.1.4.1.6302.4.1.2.5.1.1.1 | ||
| loadNameUser-provided, 32 characters | SNMPv2-TCDisplayStringr/w Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.6302.4.1.2.5.1.1.2 | ||
| loadTotalCurrentTotal output current in mA | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.5.1.1.3 | ||
| loadTotalPowerTotal output power in Watts | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.5.1.1.4 | ||
| loadPeakPowerLast24hrsMaximum output power over the past 24 hours in Watts | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.5.1.1.5 | ||
| loadPeakPowerLastWeekMaximum output power over the past 7 days in Watts | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.5.1.1.6 | ||
| loadPeakPowerLastMonthMaximum output power over the past 30 days in Watts | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.5.1.1.7 | ||
| loadTotalEnergyLast24hrsTotal output power over the past 24 hours in 0.001 kWh | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.5.1.1.8 | ||
| loadTotalEnergyLastWeekTotal output power over the past 7 days in 0.001 kWh | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.5.1.1.9 | ||
| loadTotalEnergyLastMonthTotal output power over the past 30 days in 0.001 kWh | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.5.1.1.10 | ||
| loadTotalEnergyTotal/cumulative output energy since last reset in 0.001 kWh | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.5.1.1.11 | ||
| loadClearAccumulatedValuesUsed to clear accumulated values Write 1 value to clear values | ClearDataOptionsr/w Type Values:
| .1.3.6.1.4.1.6302.4.1.2.5.1.1.12 | ||
| loadMaximumCurrentMaximum current in amps for the load; the total current is never expected to exceed this value | SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.5.1.1.13 | ||
| loadHighCurrentLimit1Threshold for high current alarm in 0.001 % | SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.5.1.1.14 | ||
| loadHighCurrentLimit2Threshold for very high current alarm in 0.001 % | SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.5.1.1.15 |
psEquipmentSignalTable
table.1.3.6.1.4.1.6302.4.1.2.15
·
1 row entry
·
2 columns
Uses the vertiv variant from
Command help
/opt/observium/mibs/vertiv.
Walk psEquipmentSignalTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NETSURE-DISTRIB-MIB' -M '/opt/observium/mibs/vertiv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NETSURE-DISTRIB-MIB::psEquipmentSignalTable'
Table of indexed equipment signal values.
An entry (conceptual row) in the psEquipment Signal Table.
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
| psEquipmentSignalTableEntryIndexThe unique sequence number of this equipment signal. | Integer32 | .1.3.6.1.4.1.6302.4.1.2.15.1.1 |
| psEquipmentSignalValueIndexed equipment signal value. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.2.15.1.2 |
alarmActiveAlarmTable
table.1.3.6.1.4.1.6302.4.1.4
·
1 row entry
·
6 columns
Uses the vertiv variant from
Command help
/opt/observium/mibs/vertiv.
Walk alarmActiveAlarmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NETSURE-DISTRIB-MIB' -M '/opt/observium/mibs/vertiv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NETSURE-DISTRIB-MIB::alarmActiveAlarmTable'
Table holding information about the currently active alarms.
An entry (conceptual row) in the alarmTrapTable.
Indexes
No indexes recorded
| Column | Syntax | OID | ||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| alarmIndexThe unique sequence number of this alarm trap. | SNMPv2-SMICounter32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.6302.4.1.4.1.1 | ||||||||||||||||||||
| alarmTimeDate and time when event occured (local time), including timezone if supported by controller. | SNMPv2-TCDateAndTime Type Constraints: range: 8range: 11Description: A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month … | .1.3.6.1.4.1.6302.4.1.4.1.2 | ||||||||||||||||||||
| alarmStatusChangeThe type of alarm change. One of (1) activated (2) deactivated | StatusChange Type Values:
| .1.3.6.1.4.1.6302.4.1.4.1.3 | ||||||||||||||||||||
| alarmSeverityThe severity of the alarm. One of (3) warning - OA, lowest level of alarm severity (4) minor - A3 (5) major - MA (6) critical - CA, highest level of alarm severity | Status Type Values:
| .1.3.6.1.4.1.6302.4.1.4.1.4 | ||||||||||||||||||||
| alarmDescriptionFree-text description of alarm. | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.6302.4.1.4.1.5 | ||||||||||||||||||||
| alarmTypeAlarm type, i.e. an integer specifying the type of alarm. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6302.4.1.4.1.6 |