NETSCREEN-CHASSIS-MIB

        This module defines the objects that are used to monitor 
device status such as Battery, Fan, Power and Temperature
    
Source file
NETSCREEN-CHASSIS-MIB
Last revised
Identity
netscreenChassis
Base OID
1.3.6.1.4.1.3224.21
Imported Objects
NETSCREEN-SMI netscreen
SNMPv2-SMI Integer32 IpAddress MODULE-IDENTITY (no object page) OBJECT-TYPE (no object page)
SNMPv2-TC DisplayString
Net-SNMP examples using the netscreen MIB directory Show commands

These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.

Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'NETSCREEN-CHASSIS-MIB' -M '/opt/observium/mibs/netscreen:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'NETSCREEN-CHASSIS-MIB::netscreenChassis'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NETSCREEN-CHASSIS-MIB' -M '/opt/observium/mibs/netscreen:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NETSCREEN-CHASSIS-MIB::netscreenChassis'
How SNMP, Net-SNMP, MIB paths, and variants work
Objects (24)
netscreenChassis.1.3.6.1.4.1.3224.21
nsPowerTable.1.3.6.1.4.1.3224.21.1
nsPowerEntry.1.3.6.1.4.1.3224.21.1.1
nsPowerIdSNMPv2-SMIInteger32.1.3.6.1.4.1.3224.21.1.1.1
nsPowerStatusSNMPv2-SMIInteger32.1.3.6.1.4.1.3224.21.1.1.2
nsPowerDescSNMPv2-TCDisplayString.1.3.6.1.4.1.3224.21.1.1.3
nsFanTable.1.3.6.1.4.1.3224.21.2
nsFanEntry.1.3.6.1.4.1.3224.21.2.1
nsFanIdSNMPv2-SMIInteger32.1.3.6.1.4.1.3224.21.2.1.1
nsFanStatusSNMPv2-SMIInteger32.1.3.6.1.4.1.3224.21.2.1.2
nsFanDescSNMPv2-TCDisplayString.1.3.6.1.4.1.3224.21.2.1.3
sysBatteryStatusSNMPv2-SMIInteger32.1.3.6.1.4.1.3224.21.3
nsTemperatureTable.1.3.6.1.4.1.3224.21.4
nsTemperatureEntry.1.3.6.1.4.1.3224.21.4.1
nsTemperatureIdSNMPv2-SMIInteger32.1.3.6.1.4.1.3224.21.4.1.1
nsTemperatureSlotIdSNMPv2-SMIInteger32.1.3.6.1.4.1.3224.21.4.1.2
nsTemperatureCurSNMPv2-SMIInteger32.1.3.6.1.4.1.3224.21.4.1.3
nsTemperatureDescSNMPv2-TCDisplayString.1.3.6.1.4.1.3224.21.4.1.4
nsSlotTable.1.3.6.1.4.1.3224.21.5
nsSlotEntry
nsSlotIdnsSubSlotId
.1.3.6.1.4.1.3224.21.5.1
nsSlotIdSNMPv2-SMIInteger32.1.3.6.1.4.1.3224.21.5.1.1
nsSlotTypeSNMPv2-TCDisplayString.1.3.6.1.4.1.3224.21.5.1.2
nsSlotStatusSNMPv2-SMIInteger32.1.3.6.1.4.1.3224.21.5.1.3
nsSlotSNSNMPv2-TCDisplayString.1.3.6.1.4.1.3224.21.5.1.4
Dependencies (3) 3 direct Show tree and compile order Hide dependency details

Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.

Dependency tree
Dependency-first compile order
  1. SNMPv2-SMIrfc
  2. NETSCREEN-SMInetscreen
  3. SNMPv2-TCrfc
  4. NETSCREEN-CHASSIS-MIBnetscreenselected