NETGEAR-BOXSERVICES-PRIVATE-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
5
Rows
5
Columns
27
boxServicesFansTable
table.1.3.6.1.4.1.4526.10.43.1.6
·
1 row entry
·
6 columns
Uses the netgear variant from
Command help
/opt/observium/mibs/netgear.
Walk boxServicesFansTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NETGEAR-BOXSERVICES-PRIVATE-MIB' -M '/opt/observium/mibs/netgear:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NETGEAR-BOXSERVICES-PRIVATE-MIB::boxServicesFansTable'
Fan
Box Services Fan Entry
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| boxServicesFansIndexUnique index of fan table entry | Integer32 Constraints: range: 0-2147483647 | .1.3.6.1.4.1.4526.10.43.1.6.1.1 | ||||||||||||||
| boxServicesFanItemTypeThe type of fan | Enumeration Enumerated Values:
| .1.3.6.1.4.1.4526.10.43.1.6.1.2 | ||||||||||||||
| boxServicesFanItemStateThe status of fan. nopower(4) - This state means the fan is present but no AC is connected. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.4526.10.43.1.6.1.3 | ||||||||||||||
| boxServicesFanSpeedThe speed of fan | OctetString Constraints: range: 0-13 | .1.3.6.1.4.1.4526.10.43.1.6.1.4 | ||||||||||||||
| boxServicesFanDutyLevelThe duty level of fan, in percents | OctetString Constraints: range: 0-13 | .1.3.6.1.4.1.4526.10.43.1.6.1.5 | ||||||||||||||
| boxServicesFanUnitIndexUnit index for an entry in the Box Services Fan Table | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.4526.10.43.1.6.1.6 |
.1.3.6.1.4.1.4526.10.43.1.7
·
1 row entry
·
4 columns
Uses the netgear variant from
Command help
/opt/observium/mibs/netgear.
Walk boxServicesPowSuppliesTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NETGEAR-BOXSERVICES-PRIVATE-MIB' -M '/opt/observium/mibs/netgear:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NETGEAR-BOXSERVICES-PRIVATE-MIB::boxServicesPowSuppliesTable'
Power supply
Box Services Power Supply Entry
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| boxServicesPowSupplyIndexUnique index of power supply table entry | Integer32 Constraints: range: 0-2147483647 | .1.3.6.1.4.1.4526.10.43.1.7.1.1 | ||||||||||||||
| boxServicesPowSupplyItemTypeThe type of power supply | Enumeration Enumerated Values:
| .1.3.6.1.4.1.4526.10.43.1.7.1.2 | ||||||||||||||
| boxServicesPowSupplyItemStateThe status of power supply. nopower(5) - This state means the power supply is present but no AC is connected. incompatible(7) - This state is possible on boards capable of pluggable Power supplies | Enumeration Enumerated Values:
| .1.3.6.1.4.1.4526.10.43.1.7.1.3 | ||||||||||||||
| boxServicesPowerSuppUnitIndexUnit index for an entry in the Box Services Power Supply Table | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.4526.10.43.1.7.1.4 |
.1.3.6.1.4.1.4526.10.43.1.8
·
1 row entry
·
5 columns
Uses the netgear variant from
Command help
/opt/observium/mibs/netgear.
Walk boxServicesTempSensorsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NETGEAR-BOXSERVICES-PRIVATE-MIB' -M '/opt/observium/mibs/netgear:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NETGEAR-BOXSERVICES-PRIVATE-MIB::boxServicesTempSensorsTable'
Temperature sensor
Box Services Temperature Sensor Entry
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| boxServicesUnitIndexUnit index for an entry in the Box Services Temperature Sensor Table | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.4526.10.43.1.8.1.1 | ||||||||||||||
| boxServicesTempSensorIndexUnique index of temperature sensor table entry | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.4526.10.43.1.8.1.2 | ||||||||||||||
| boxServicesTempSensorTypeThe type of temperature sensor | Enumeration Enumerated Values:
| .1.3.6.1.4.1.4526.10.43.1.8.1.3 | ||||||||||||||
boxServicesTempSensorStateobsolete The state of temperature sensor | BoxsTemperatureStatus Type Values:
| .1.3.6.1.4.1.4526.10.43.1.8.1.4 | ||||||||||||||
| boxServicesTempSensorTemperatureThe temperature value reported by sensor | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.4526.10.43.1.8.1.5 |
boxServicesTempUnitTable
table.1.3.6.1.4.1.4526.10.43.1.15
·
1 row entry
·
3 columns
Uses the netgear variant from
Command help
/opt/observium/mibs/netgear.
Walk boxServicesTempUnitTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NETGEAR-BOXSERVICES-PRIVATE-MIB' -M '/opt/observium/mibs/netgear:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NETGEAR-BOXSERVICES-PRIVATE-MIB::boxServicesTempUnitTable'
Temperature status table
Box Services Temperature Unit Entry
Indexes
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| boxServicesTempUnitIndexUnit index for an entry in the Box Services Temperature Unit Table | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.4526.10.43.1.15.1.1 | ||||||||||||||
| boxServicesTempUnitStateThe temperature state of the unit | BoxsTemperatureStatus Type Values:
| .1.3.6.1.4.1.4526.10.43.1.15.1.2 | ||||||||||||||
| boxServicesTempUnitTemperatureThe highest temperature currently reported by any sensor on the unit | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.4526.10.43.1.15.1.3 |
.1.3.6.1.4.1.4526.10.43.1.16
·
1 row entry
·
9 columns
Uses the netgear variant from
Command help
/opt/observium/mibs/netgear.
Walk boxServicesFiberPortsOpticsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'NETGEAR-BOXSERVICES-PRIVATE-MIB' -M '/opt/observium/mibs/netgear:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NETGEAR-BOXSERVICES-PRIVATE-MIB::boxServicesFiberPortsOpticsTable'
Fiber ports optics data table
Box Services Fiber ports optics Entry
Indexes
| Column | Syntax | OID |
|---|---|---|
| boxServicesFiberPortIndexPort index for an entry in the Box Services Fiber ports optics table | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.4526.10.43.1.16.1.1 |
| boxServicesFiberPortOpticsTemperatureThe temperature measured at this fiber port. It is measured in degree celcius. | DEGREESRFC1213-MIBDisplayString | .1.3.6.1.4.1.4526.10.43.1.16.1.2 |
| boxServicesFiberPortOpticsVoltageThe voltage measured at this fiber port. It is measured in volts. | VoltsRFC1213-MIBDisplayString | .1.3.6.1.4.1.4526.10.43.1.16.1.3 |
| boxServicesFiberPortOpticsCurrentThe current measured at this fiber port. It is measured in milli amps. | MilliampsRFC1213-MIBDisplayString | .1.3.6.1.4.1.4526.10.43.1.16.1.4 |
| boxServicesFiberPortOpticsPowerOutThe output power measured at this fiber port. It is measured in dBm. | dBmRFC1213-MIBDisplayString | .1.3.6.1.4.1.4526.10.43.1.16.1.5 |
| boxServicesFiberPortOpticsPowerInThe input power measured at this fiber port. It is measured in dBm. | dBmRFC1213-MIBDisplayString | .1.3.6.1.4.1.4526.10.43.1.16.1.6 |
| boxServicesFiberPortOpticsTxFaultThe tx fault status of fiber port. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.4526.10.43.1.16.1.7 |
| boxServicesFiberPortOpticsLosThe Los status of fiber port. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.4526.10.43.1.16.1.8 |
| boxServicesFiberPortOpticsFaultStatusThe fault status of fiber port. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.4526.10.43.1.16.1.9 |