boxServicesFansTable
table.1.3.6.1.4.1.4526.10.43.1.6
·
1 row entry
·
6 columns
Fan
Box Services Fan Entry
Indexes
boxServicesFanUnitIndex boxServicesFansIndex
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
boxServicesFansIndex
Unique index of fan table entry
|
Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.4526.10.43.1.6.1.1 |
||||||||||||||
|
boxServicesFanItemType
The type of fan
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.4526.10.43.1.6.1.2 |
||||||||||||||
|
boxServicesFanItemState
The status of fan. nopower(4) - This state means the fan is present but no AC is connected.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.4526.10.43.1.6.1.3 |
||||||||||||||
|
boxServicesFanSpeed
The speed of fan
|
OctetString Constraints: range: 0-13 |
.1.3.6.1.4.1.4526.10.43.1.6.1.4 |
||||||||||||||
|
boxServicesFanDutyLevel
The duty level of fan, in percents
|
OctetString Constraints: range: 0-13 |
.1.3.6.1.4.1.4526.10.43.1.6.1.5 |
||||||||||||||
|
boxServicesFanUnitIndex
Unit index for an entry in the Box Services Fan Table
|
SNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.4526.10.43.1.6.1.6 |
.1.3.6.1.4.1.4526.10.43.1.7
·
1 row entry
·
4 columns
Power supply
Box Services Power Supply Entry
Indexes
boxServicesPowerSuppUnitIndex boxServicesPowSupplyIndex
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
boxServicesPowSupplyIndex
Unique index of power supply table entry
|
Integer32 Constraints: range: 0-2147483647 |
.1.3.6.1.4.1.4526.10.43.1.7.1.1 |
||||||||||||||
|
boxServicesPowSupplyItemType
The type of power supply
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.4526.10.43.1.7.1.2 |
||||||||||||||
|
boxServicesPowSupplyItemState
The status of power supply. nopower(5) - This state means the power supply is present but no AC is connected.
incompatible(7) - This state is possible on boards capable of pluggable Power supplies |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.4526.10.43.1.7.1.3 |
||||||||||||||
|
boxServicesPowerSuppUnitIndex
Unit index for an entry in the Box Services Power Supply Table
|
SNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.4526.10.43.1.7.1.4 |
.1.3.6.1.4.1.4526.10.43.1.8
·
1 row entry
·
5 columns
Temperature sensor
Box Services Temperature Sensor Entry
Indexes
boxServicesUnitIndex boxServicesTempSensorIndex
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
boxServicesUnitIndex
Unit index for an entry in the Box Services Temperature Sensor Table
|
SNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.4526.10.43.1.8.1.1 |
||||||||||||||
|
boxServicesTempSensorIndex
Unique index of temperature sensor table entry
|
SNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.4526.10.43.1.8.1.2 |
||||||||||||||
|
boxServicesTempSensorType
The type of temperature sensor
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.4526.10.43.1.8.1.3 |
||||||||||||||
|
boxServicesTempSensorState
obsolete
The state of temperature sensor
|
BoxsTemperatureStatus Textual Convention: BoxsTemperatureStatus EnumerationType Values:
|
.1.3.6.1.4.1.4526.10.43.1.8.1.4 |
||||||||||||||
|
boxServicesTempSensorTemperature
The temperature value reported by sensor
|
SNMPv2-SMIInteger32 Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4526.10.43.1.8.1.5 |
boxServicesTempUnitTable
table.1.3.6.1.4.1.4526.10.43.1.15
·
1 row entry
·
3 columns
Temperature status table
Box Services Temperature Unit Entry
Indexes
boxServicesTempUnitIndex
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
boxServicesTempUnitIndex
Unit index for an entry in the Box Services Temperature Unit Table
|
SNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.4526.10.43.1.15.1.1 |
||||||||||||||
|
boxServicesTempUnitState
The temperature state of the unit
|
BoxsTemperatureStatus Textual Convention: BoxsTemperatureStatus EnumerationType Values:
|
.1.3.6.1.4.1.4526.10.43.1.15.1.2 |
||||||||||||||
|
boxServicesTempUnitTemperature
The highest temperature currently reported by any sensor on the unit
|
SNMPv2-SMIInteger32 Textual Convention: SNMPv2-SMIInteger32 Integer32Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4526.10.43.1.15.1.3 |
.1.3.6.1.4.1.4526.10.43.1.16
·
1 row entry
·
9 columns
Fiber ports optics data table
Box Services Fiber ports optics Entry
Indexes
boxServicesFiberPortIndex
| Column | Syntax | OID |
|---|---|---|
|
boxServicesFiberPortIndex
Port index for an entry in the Box Services Fiber ports optics table
|
SNMPv2-SMIUnsigned32 Textual Convention: SNMPv2-SMIUnsigned32 Unsigned32Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.4526.10.43.1.16.1.1 |
|
boxServicesFiberPortOpticsTemperature
The temperature measured at this fiber port. It is
measured in degree celcius. |
DEGREESRFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.4526.10.43.1.16.1.2 |
|
boxServicesFiberPortOpticsVoltage
The voltage measured at this fiber port. It is
measured in volts. |
VoltsRFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.4526.10.43.1.16.1.3 |
|
boxServicesFiberPortOpticsCurrent
The current measured at this fiber port. It is
measured in milli amps. |
MilliampsRFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.4526.10.43.1.16.1.4 |
|
boxServicesFiberPortOpticsPowerOut
The output power measured at this fiber port. It is
measured in dBm. |
dBmRFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.4526.10.43.1.16.1.5 |
|
boxServicesFiberPortOpticsPowerIn
The input power measured at this fiber port. It is
measured in dBm. |
dBmRFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.4526.10.43.1.16.1.6 |
|
boxServicesFiberPortOpticsTxFault
The tx fault status of fiber port.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.4526.10.43.1.16.1.7 |
|
boxServicesFiberPortOpticsLos
The Los status of fiber port.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.4526.10.43.1.16.1.8 |
|
boxServicesFiberPortOpticsFaultStatus
The fault status of fiber port.
|
RFC1213-MIBDisplayString Textual Convention: RFC1213-MIBDisplayString OctetString |
.1.3.6.1.4.1.4526.10.43.1.16.1.9 |