upsmgBatteryFault | .1.3.6.1.4.1.705.1.11.0.1 | Trap UPS Battery entering Fault status. |
upsmgFromLowCondition
| .1.3.6.1.4.1.705.1.11.0.10 | Trap UPS exiting low condition. |
upsmgOnBattery
| .1.3.6.1.4.1.705.1.11.0.11 | Trap UPS is on Battery. |
upsmgReturnFromBattery
| .1.3.6.1.4.1.705.1.11.0.12 | Trap UPS returned from battery. |
upsmgOnByPass | .1.3.6.1.4.1.705.1.11.0.13 | Trap UPS is on by pass. |
upsmgReturnFromByPass | .1.3.6.1.4.1.705.1.11.0.14 | Trap UPS return from by pass. |
upsmgByPassUnavailable | .1.3.6.1.4.1.705.1.11.0.15 | Trap UPS by pass unavailable. |
upsmgByPassAvailable | .1.3.6.1.4.1.705.1.11.0.16 | Trap UPS by pass available. |
upsmgUtilityFailure | .1.3.6.1.4.1.705.1.11.0.17 | Trap UPS utility power failed. |
upsmgUtilityRestored | .1.3.6.1.4.1.705.1.11.0.18 | Trap UPS utility power restored. |
upsmgOnBoost | .1.3.6.1.4.1.705.1.11.0.19 | Trap UPS is on boost. |
upsmgBatteryOK | .1.3.6.1.4.1.705.1.11.0.2 | Trap UPS Battery returned to OK status. |
upsmgReturnFromBoost | .1.3.6.1.4.1.705.1.11.0.20 | Trap UPS has returned from boost. |
upsmgOverLoad | .1.3.6.1.4.1.705.1.11.0.21 | Trap UPS has overload condition. |
upsmgLoadOK | .1.3.6.1.4.1.705.1.11.0.22 | Trap UPS quit overload condition. |
upsmgOverTemperature | .1.3.6.1.4.1.705.1.11.0.23 | Trap UPS has overtemperature condition. |
upsmgTemperatureOK | .1.3.6.1.4.1.705.1.11.0.24 | Trap UPS quit overtemperature condition. |
upsmgOnToStart
| .1.3.6.1.4.1.705.1.11.0.25 | Trap UPS on sequence started. |
upsmgOnAbort
| .1.3.6.1.4.1.705.1.11.0.26 | Trap UPS on sequence cancelled. |
upsmgOnInProgress
| .1.3.6.1.4.1.705.1.11.0.27 | Trap UPS on sequence in progress in ups. |
upsmgOnComplete
| .1.3.6.1.4.1.705.1.11.0.28 | Trap UPS on sequence completed. |
upsmgOffToStart
| .1.3.6.1.4.1.705.1.11.0.29 | Trap UPS off sequence started. |
upsmgBatteryReplacementIndicated | .1.3.6.1.4.1.705.1.11.0.3 | Trap UPS battery need to be replaced. |
upsmgOffAbort
| .1.3.6.1.4.1.705.1.11.0.30 | Trap UPS off sequence cancelled. |
upsmgOffInProgress
| .1.3.6.1.4.1.705.1.11.0.31 | Trap UPS off sequence in progress in ups. |
upsmgOffComplete
| .1.3.6.1.4.1.705.1.11.0.32 | Trap UPS off sequence completed. |
upsmgToggleToStart
| .1.3.6.1.4.1.705.1.11.0.33 | Trap UPS toggle (off/on) sequence started. |
upsmgToggleAbort
| .1.3.6.1.4.1.705.1.11.0.34 | Trap UPS toggle (off/on) sequence cancelled. |
upsmgToggleInProgress
| .1.3.6.1.4.1.705.1.11.0.35 | Trap UPS toggle (off/on) sequence in progress in ups. |
upsmgToggleComplete
| .1.3.6.1.4.1.705.1.11.0.36 | Trap UPS toggle (off/on) sequence completed. |
upsmgCommunicationFailure | .1.3.6.1.4.1.705.1.11.0.37 | Trap UPS serial communication failed. |
upsmgCommunicationRestored | .1.3.6.1.4.1.705.1.11.0.38 | Trap UPS serial communication restored. |
upsmgInputBad | .1.3.6.1.4.1.705.1.11.0.39 | Trap UPS input has bad condition. |
upsmgBatteryReplaceNotIndicated | .1.3.6.1.4.1.705.1.11.0.4 | Trap UPS battery does not need to be replaced. |
upsmgInputOK | .1.3.6.1.4.1.705.1.11.0.40 | Trap UPS input quit bad condition. |
upsmgBatteryUnavailable | .1.3.6.1.4.1.705.1.11.0.41 | Trap UPS battery is unavailable. |
upsmgBatteryAvailable | .1.3.6.1.4.1.705.1.11.0.42 | Trap UPS battery return from unavailable condition. |
upsmgAtLowRecharge
| .1.3.6.1.4.1.705.1.11.0.43 | Trap UPS waiting for battery charging condition. |
upsmgFromLowRecharge
| .1.3.6.1.4.1.705.1.11.0.44 | Trap UPS reached battery charging condition. |
upsmgDiagnosticTestFail | .1.3.6.1.4.1.705.1.11.0.45 | Trap UPS self test failed. |
upsmgDiagnosticTestOK | .1.3.6.1.4.1.705.1.11.0.46 | Trap UPS self test succeeded. |
upsmgBatteryTestOK | .1.3.6.1.4.1.705.1.11.0.47 | Trap UPS passed battery test. |
upsmgBatteryTestFail | .1.3.6.1.4.1.705.1.11.0.48 | Trap UPS failed battery test. |
upsmgExternalAlarmActive
| .1.3.6.1.4.1.705.1.11.0.49 | Trap UPS enter environment external alarm. |
upsmgAtLowBattery
| .1.3.6.1.4.1.705.1.11.0.5 | Trap UPS battery reached low condition. |
upsmgExternalAlarmInactive
| .1.3.6.1.4.1.705.1.11.0.50 | Trap UPS exit environment external alarm. |
upsmgOnBuck | .1.3.6.1.4.1.705.1.11.0.51 | Trap UPS is on buck. |
upsmgReturnFromBuck | .1.3.6.1.4.1.705.1.11.0.52 | Trap UPS has returned from buck. |
upsmgEnvironComFailure | .1.3.6.1.4.1.705.1.11.0.53 | Environment Probe communication failure. |
upsmgEnvironComOK | .1.3.6.1.4.1.705.1.11.0.54 | Environment Probe communication restored. |
upsmgEnvironTemperatureLow | .1.3.6.1.4.1.705.1.11.0.55 | Temperature is below low threshold. |
upsmgEnvironTemperatureHigh | .1.3.6.1.4.1.705.1.11.0.56 | Temperature is above high threshold. |
upsmgEnvironTemperatureOK | .1.3.6.1.4.1.705.1.11.0.57 | Temperature is in normal range. |
upsmgEnvironHumidityLow | .1.3.6.1.4.1.705.1.11.0.58 | Humidity is below low threshold. |
upsmgEnvironHumidityHigh | .1.3.6.1.4.1.705.1.11.0.59 | Humidity is above high threshold. |
upsmgFromLowBattery
| .1.3.6.1.4.1.705.1.11.0.6 | Trap UPS battery returned from low condition. |
upsmgEnvironHumidityOK | .1.3.6.1.4.1.705.1.11.0.60 | Humidity is in normal range. |
upsmgEnvironInput1Closed | .1.3.6.1.4.1.705.1.11.0.61 | Input #1 is Closed. |
upsmgEnvironInput1Open | .1.3.6.1.4.1.705.1.11.0.62 | Input #1 is Open. |
upsmgEnvironInput2Closed | .1.3.6.1.4.1.705.1.11.0.63 | Input #2 is Closed. |
upsmgEnvironInput2Open | .1.3.6.1.4.1.705.1.11.0.64 | Input #2 is Open. |
upsRedundancyLost | .1.3.6.1.4.1.705.1.11.0.65 | Redundancy Lost. |
upsRedundancyOK | .1.3.6.1.4.1.705.1.11.0.66 | Redundancy Recovered. |
upsProtectionLost | .1.3.6.1.4.1.705.1.11.0.67 | Protection Lost. |
upsProtectionOK | .1.3.6.1.4.1.705.1.11.0.68 | Protection Recovered. |
upsmgChargerFault | .1.3.6.1.4.1.705.1.11.0.7 | Trap UPS battery charger is not active. |
upsmgChargerOK | .1.3.6.1.4.1.705.1.11.0.8 | Trap UPS battery charger is active. |
upsmgAtLowCondition
| .1.3.6.1.4.1.705.1.11.0.9 | Trap UPS entering low condition. |