ME1200-SYSUTIL-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
4
Rows
4
Columns
11
.1.3.6.1.4.1.9.9.815.1.24.1.3.2
·
1 row entry
·
5 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk me1200SysutilStatusPowerSupplyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ME1200-SYSUTIL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ME1200-SYSUTIL-MIB::me1200SysutilStatusPowerSupplyTable'
Table of power supply status.
Each row contains the power supply status.
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
| me1200SysutilStatusPowerSupplySwitchIdThe identification of switch. | Integer32 Constraints: range: 1-16 | .1.3.6.1.4.1.9.9.815.1.24.1.3.2.1.1 | ||||||
| me1200SysutilStatusPowerSupplyPsuIdThe identification of power supply. | Integer32 Constraints: range: 1-2 | .1.3.6.1.4.1.9.9.815.1.24.1.3.2.1.2 | ||||||
| me1200SysutilStatusPowerSupplyStateThe state of power supply. | ME1200SysutilPowerSupplyStateType Type Values:
| .1.3.6.1.4.1.9.9.815.1.24.1.3.2.1.3 | ||||||
| me1200SysutilStatusPowerSupplyDescriptionThe description of power supply. | OctetString Constraints: range: 0-30 | .1.3.6.1.4.1.9.9.815.1.24.1.3.2.1.4 | ||||||
| me1200SysutilVoltageStatusStatus of differnt system voltages. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.9.9.815.1.24.1.3.2.1.5 |
.1.3.6.1.4.1.9.9.815.1.24.1.3.3
·
1 row entry
·
2 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk me1200SysutilStatusSystemLedTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ME1200-SYSUTIL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ME1200-SYSUTIL-MIB::me1200SysutilStatusSystemLedTable'
Table of system LED status.
Each row contains the system LED status.
| Column | Syntax | OID |
|---|---|---|
| me1200SysutilStatusSystemLedSwitchIdThe identification of switch. | Integer32 Constraints: range: 1-16 | .1.3.6.1.4.1.9.9.815.1.24.1.3.3.1.1 |
| me1200SysutilStatusSystemLedDescriptionThe description of system LED status. | OctetString Constraints: range: 0-127 | .1.3.6.1.4.1.9.9.815.1.24.1.3.3.1.2 |
.1.3.6.1.4.1.9.9.815.1.24.1.4.1
·
1 row entry
·
2 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk me1200SysutilControlRebootTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ME1200-SYSUTIL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ME1200-SYSUTIL-MIB::me1200SysutilControlRebootTable'
This is a table to reboot a swicth
Each switch has a set of parameters
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
| me1200SysutilControlRebootSwitchIdThe identification of switch. | Integer32 Constraints: range: 1-16 | .1.3.6.1.4.1.9.9.815.1.24.1.4.1.1.1 | ||||||
| me1200SysutilControlRebootTypeType of reboot. noReboot(0) does not reboot. coldReboot(1) is to do cold reboot. warmReboot(2) is to do warm reboot, but this is optional. The OID of vtssSysutilCapabilitiesWarmRebootSupported tells if warm reboot is su… | ME1200SysutilRebootTyper/w Type Values:
| .1.3.6.1.4.1.9.9.815.1.24.1.4.1.1.2 |
.1.3.6.1.4.1.9.9.815.1.24.1.4.2
·
1 row entry
·
2 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk me1200SysutilControlSystemLedTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ME1200-SYSUTIL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ME1200-SYSUTIL-MIB::me1200SysutilControlSystemLedTable'
This is a table to clear the system LED error status
Each switch has a set of parameters
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| me1200SysutilControlSystemLedSwitchIdThe identification of switch. | Integer32 Constraints: range: 1-16 | .1.3.6.1.4.1.9.9.815.1.24.1.4.2.1.1 | ||||||||||||
| me1200SysutilControlSystemLedClearStatusType of system LED status clearing.all(0) is used to clear all error status of the system LED and back to normal indication. fatal(1) is used to clear fatal error status of the system LED. software(2) is used to clear g… | ME1200SysutilSystemLedClearTyper/w Type Values:
| .1.3.6.1.4.1.9.9.815.1.24.1.4.2.1.2 |