MAS-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
3
Rows
3
Columns
105
netscalerTable
table.1.3.6.1.4.1.5951.7.3.2
·
1 row entry
·
46 columns
Uses the citrix variant from
Command help
/opt/observium/mibs/citrix.
Walk netscalerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'MAS-MIB' -M '/opt/observium/mibs/citrix:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'MAS-MIB::netscalerTable'
netscalertable
...
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| nsIpAddressTypeType of nsIpAddress | INET-ADDRESS-MIBInetAddressType Type Values:
| .1.3.6.1.4.1.5951.7.3.2.1.1 | ||||||||||||||
| nsIpAddressIP Address for this managed device | INET-ADDRESS-MIBInetAddress Type Constraints: range: 0..255 | .1.3.6.1.4.1.5951.7.3.2.1.2 | ||||||||||||||
| nsHostIPAddressTypeType of nsHostIPAddress | INET-ADDRESS-MIBInetAddressType Type Values:
| .1.3.6.1.4.1.5951.7.3.2.1.3 | ||||||||||||||
| nsHostIPAddressHost IPAddress where VM is provisioned | INET-ADDRESS-MIBInetAddress Type Constraints: range: 0..255 | .1.3.6.1.4.1.5951.7.3.2.1.4 | ||||||||||||||
| nsProfileNameDevice Profile Name that is attached with this managed device | OctetString | .1.3.6.1.4.1.5951.7.3.2.1.5 | ||||||||||||||
| nsNameName of managed device | OctetString | .1.3.6.1.4.1.5951.7.3.2.1.6 | ||||||||||||||
| nsNetmaskTypeType of nsNetmask | INET-ADDRESS-MIBInetAddressType Type Values:
| .1.3.6.1.4.1.5951.7.3.2.1.7 | ||||||||||||||
| nsNetmaskNetmask of managed device | INET-ADDRESS-MIBInetAddress Type Constraints: range: 0..255 | .1.3.6.1.4.1.5951.7.3.2.1.8 | ||||||||||||||
| nsGatewayTypeType of nsGateway | INET-ADDRESS-MIBInetAddressType Type Values:
| .1.3.6.1.4.1.5951.7.3.2.1.9 | ||||||||||||||
| nsGatewayDefault Gateway of managed device | INET-ADDRESS-MIBInetAddress Type Constraints: range: 0..255 | .1.3.6.1.4.1.5951.7.3.2.1.10 | ||||||||||||||
| nsHostnameAssign hostname to managed device, if this is not provided, name will be set as host name | OctetString | .1.3.6.1.4.1.5951.7.3.2.1.11 | ||||||||||||||
| nsDescriptionDescription of managed device | OctetString | .1.3.6.1.4.1.5951.7.3.2.1.12 | ||||||||||||||
| nsVersionDevice Version | OctetString | .1.3.6.1.4.1.5951.7.3.2.1.13 | ||||||||||||||
| nsUuidUUID of VM Instance | OctetString | .1.3.6.1.4.1.5951.7.3.2.1.14 | ||||||||||||||
| nsInstanceStateState of device, UP only if device accessible | OctetString | .1.3.6.1.4.1.5951.7.3.2.1.15 | ||||||||||||||
| nsVirtualFunctionsVirtual Functions assigned to VM Instance | OctetString | .1.3.6.1.4.1.5951.7.3.2.1.16 | ||||||||||||||
| nsSslVirtualFunctionsSSL Virtual Functions assigned to VM Instance | OctetString | .1.3.6.1.4.1.5951.7.3.2.1.17 | ||||||||||||||
| nsVmStateState of Virtual Machine (Running | Halted) | OctetString | .1.3.6.1.4.1.5951.7.3.2.1.18 | ||||||||||||||
| nsNumberOfCPUNumber of CPU that is assigned to VM Instance | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.5951.7.3.2.1.19 | ||||||||||||||
| nsVmMemoryTotalTotal Memory of VM Instance in MB | OctetString | .1.3.6.1.4.1.5951.7.3.2.1.21 | ||||||||||||||
| nsUptimeUptime of device | OctetString | .1.3.6.1.4.1.5951.7.3.2.1.26 | ||||||||||||||
| nsNumberOfSSLCoresAssign number of ssl virtual functions to VM Instance | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.5951.7.3.2.1.27 | ||||||||||||||
| nsCpuCoreMgmtManagement CPU cores assigned to VM Instance | OctetString | .1.3.6.1.4.1.5951.7.3.2.1.28 | ||||||||||||||
| nsCpuCorePEPacket Engine cores assigned to VM Instance | OctetString | .1.3.6.1.4.1.5951.7.3.2.1.29 | ||||||||||||||
| nsVmDescriptionDescription | OctetString | .1.3.6.1.4.1.5951.7.3.2.1.30 | ||||||||||||||
| nsThroughputAssign throughput in Mbps to VM Instance | OctetString | .1.3.6.1.4.1.5951.7.3.2.1.31 | ||||||||||||||
| nsNumberOfCoresNumber of cores that are assigned to VM Instance | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.5951.7.3.2.1.32 | ||||||||||||||
| nsNsCPUUsageCPU Usage (%) of Citrix ADC Instance | OctetString | .1.3.6.1.4.1.5951.7.3.2.1.33 | ||||||||||||||
| nsNsMemoryUsageMemory Usage (%) | OctetString | .1.3.6.1.4.1.5951.7.3.2.1.35 | ||||||||||||||
| nsNsTxOut Throughput of Citrix ADC Instance in Mbps | OctetString | .1.3.6.1.4.1.5951.7.3.2.1.36 | ||||||||||||||
| nsNsRxIn Throughput of Citrix ADC Instance in Mbps | OctetString | .1.3.6.1.4.1.5951.7.3.2.1.37 | ||||||||||||||
| nsHttpReqHTTP Requests/second | OctetString | .1.3.6.1.4.1.5951.7.3.2.1.38 | ||||||||||||||
| nsUpsinceUpsince of managed device | OctetString | .1.3.6.1.4.1.5951.7.3.2.1.39 | ||||||||||||||
| nsLicenseFeature License for Citrix ADC Instance, needs to be set while provisioning (standard, enterprise, platinum, SWG) | OctetString | .1.3.6.1.4.1.5951.7.3.2.1.40 | ||||||||||||||
| nsHaMasterStateMaster State (Primary/Secondary) | OctetString | .1.3.6.1.4.1.5951.7.3.2.1.41 | ||||||||||||||
| nsHaIPAddressTypeType of nsHaIPAddress | INET-ADDRESS-MIBInetAddressType Type Values:
| .1.3.6.1.4.1.5951.7.3.2.1.42 | ||||||||||||||
| nsHaIPAddressPeer IP Address | INET-ADDRESS-MIBInetAddress Type Constraints: range: 0..255 | .1.3.6.1.4.1.5951.7.3.2.1.43 | ||||||||||||||
| nsNodeStateNode State of Citrix ADC Instance | OctetString | .1.3.6.1.4.1.5951.7.3.2.1.44 | ||||||||||||||
| nsHaSyncHA Synchronization State | OctetString | .1.3.6.1.4.1.5951.7.3.2.1.45 | ||||||||||||||
| nsPpsAssign packets per seconds to Citrix ADC Instance | OctetString | .1.3.6.1.4.1.5951.7.3.2.1.46 | ||||||||||||||
| nsNumberOfSslCoresUpNumber of SSL Cores Up | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.5951.7.3.2.1.47 | ||||||||||||||
| nsIfOby1Network 0/1 on VM Instance | OctetString | .1.3.6.1.4.1.5951.7.3.2.1.48 | ||||||||||||||
| nsIf0by2Network 0/2 on VM Instance | OctetString | .1.3.6.1.4.1.5951.7.3.2.1.49 | ||||||||||||||
| nsNsVLANIdVLAN Id | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.5951.7.3.2.1.50 | ||||||||||||||
| nsNsVLANTaggedNSVLAN Tagged | OctetString | .1.3.6.1.4.1.5951.7.3.2.1.51 | ||||||||||||||
| nsVlanTypeVLAN Type, Citrix ADC or L2 VLAN | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.5951.7.3.2.1.52 |
cloudBridgeTable
table.1.3.6.1.4.1.5951.7.3.3
·
1 row entry
·
34 columns
Uses the citrix variant from
Command help
/opt/observium/mibs/citrix.
Walk cloudBridgeTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'MAS-MIB' -M '/opt/observium/mibs/citrix:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'MAS-MIB::cloudBridgeTable'
cloudBridgetable
...
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| cbIpAddressTypeType of cbIpAddress | INET-ADDRESS-MIBInetAddressType Type Values:
| .1.3.6.1.4.1.5951.7.3.3.1.1 | ||||||||||||||
| cbIpAddressIP Address for this managed device | INET-ADDRESS-MIBInetAddress Type Constraints: range: 0..255 | .1.3.6.1.4.1.5951.7.3.3.1.2 | ||||||||||||||
| cbHostIPAddressTypeType of cbHostIPAddress | INET-ADDRESS-MIBInetAddressType Type Values:
| .1.3.6.1.4.1.5951.7.3.3.1.3 | ||||||||||||||
| cbHostIPAddressHost IPAddress where VM is provisioned | INET-ADDRESS-MIBInetAddress Type Constraints: range: 0..255 | .1.3.6.1.4.1.5951.7.3.3.1.4 | ||||||||||||||
| cbProfileNameDevice Profile Name that is attached with this managed device | OctetString | .1.3.6.1.4.1.5951.7.3.3.1.5 | ||||||||||||||
| cbNameName of managed device | OctetString | .1.3.6.1.4.1.5951.7.3.3.1.6 | ||||||||||||||
| cbNetmaskTypeType of cbNetmask | INET-ADDRESS-MIBInetAddressType Type Values:
| .1.3.6.1.4.1.5951.7.3.3.1.7 | ||||||||||||||
| cbNetmaskNetmask of managed device | INET-ADDRESS-MIBInetAddress Type Constraints: range: 0..255 | .1.3.6.1.4.1.5951.7.3.3.1.8 | ||||||||||||||
| cbGatewayTypeType of cbGateway | INET-ADDRESS-MIBInetAddressType Type Values:
| .1.3.6.1.4.1.5951.7.3.3.1.9 | ||||||||||||||
| cbGatewayDefault Gateway of managed device | INET-ADDRESS-MIBInetAddress Type Constraints: range: 0..255 | .1.3.6.1.4.1.5951.7.3.3.1.10 | ||||||||||||||
| cbHostnameAssign hostname to managed device, if this is not provided, name will be set as host name | OctetString | .1.3.6.1.4.1.5951.7.3.3.1.11 | ||||||||||||||
| cbDescriptionDescription of managed device | OctetString | .1.3.6.1.4.1.5951.7.3.3.1.12 | ||||||||||||||
| cbVersionDevice Version | OctetString | .1.3.6.1.4.1.5951.7.3.3.1.13 | ||||||||||||||
| cbInstanceStateState of device, UP only if device accessible | OctetString | .1.3.6.1.4.1.5951.7.3.3.1.14 | ||||||||||||||
| cbUuidUUID of VM Instance | OctetString | .1.3.6.1.4.1.5951.7.3.3.1.15 | ||||||||||||||
| cbVirtualFunctionsVirtual Functions assigned to VM Instance | OctetString | .1.3.6.1.4.1.5951.7.3.3.1.16 | ||||||||||||||
| cbVmStateState of Virtual Machine (Running | Halted) | OctetString | .1.3.6.1.4.1.5951.7.3.3.1.17 | ||||||||||||||
| cbNumberOfCPUNumber of CPU that is assigned to VM Instance | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.5951.7.3.3.1.18 | ||||||||||||||
| cbVmCPUUsageCPU Usage (%) of VM Instance | OctetString | .1.3.6.1.4.1.5951.7.3.3.1.19 | ||||||||||||||
| cbVmMemoryTotalTotal Memory of VM Instance in MB | OctetString | .1.3.6.1.4.1.5951.7.3.3.1.20 | ||||||||||||||
| cbVmMemoryFreeFree Memory (MB) available in VM Instance | OctetString | .1.3.6.1.4.1.5951.7.3.3.1.21 | ||||||||||||||
| cbVmMemoryUsageMemory Usage (%) of VM Instance | OctetString | .1.3.6.1.4.1.5951.7.3.3.1.22 | ||||||||||||||
| cbUptimeUptime of device | OctetString | .1.3.6.1.4.1.5951.7.3.3.1.25 | ||||||||||||||
| cbDiskAllocationDisk allocation for VM Instance | OctetString | .1.3.6.1.4.1.5951.7.3.3.1.30 | ||||||||||||||
| cbAPAIPADDRESSTypeType of cbAPAIPADDRESS | INET-ADDRESS-MIBInetAddressType Type Values:
| .1.3.6.1.4.1.5951.7.3.3.1.47 | ||||||||||||||
| cbAPAIPADDRESSaPA IP Address | INET-ADDRESS-MIBInetAddress Type Constraints: range: 0..255 | .1.3.6.1.4.1.5951.7.3.3.1.48 | ||||||||||||||
| cbAPANetMaskTypeType of cbAPANetMask | INET-ADDRESS-MIBInetAddressType Type Values:
| .1.3.6.1.4.1.5951.7.3.3.1.49 | ||||||||||||||
| cbAPANetMaskaPA Netmask | INET-ADDRESS-MIBInetAddress Type Constraints: range: 0..255 | .1.3.6.1.4.1.5951.7.3.3.1.50 | ||||||||||||||
| cbAPAGatewayTypeType of cbAPAGateway | INET-ADDRESS-MIBInetAddressType Type Values:
| .1.3.6.1.4.1.5951.7.3.3.1.51 | ||||||||||||||
| cbAPAGatewayaPA Gateway | INET-ADDRESS-MIBInetAddress Type Constraints: range: 0..255 | .1.3.6.1.4.1.5951.7.3.3.1.52 | ||||||||||||||
| cbPluginIPADDRESSTypeType of cbPluginIPADDRESS | INET-ADDRESS-MIBInetAddressType Type Values:
| .1.3.6.1.4.1.5951.7.3.3.1.53 | ||||||||||||||
| cbPluginIPADDRESSPlugin IP Address | INET-ADDRESS-MIBInetAddress Type Constraints: range: 0..255 | .1.3.6.1.4.1.5951.7.3.3.1.54 | ||||||||||||||
| cbMgmtIPAddressTypeType of cbMgmtIPAddress | INET-ADDRESS-MIBInetAddressType Type Values:
| .1.3.6.1.4.1.5951.7.3.3.1.57 | ||||||||||||||
| cbMgmtIPAddressManagement IP Address for this Managed Device | INET-ADDRESS-MIBInetAddress Type Constraints: range: 0..255 | .1.3.6.1.4.1.5951.7.3.3.1.58 |
.1.3.6.1.4.1.5951.7.3.4
·
1 row entry
·
25 columns
Uses the citrix variant from
Command help
/opt/observium/mibs/citrix.
Walk cloudBridgeAcceleratorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'MAS-MIB' -M '/opt/observium/mibs/citrix:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'MAS-MIB::cloudBridgeAcceleratorTable'
cloudBridgeAcceleratortable
...
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| cbAcceleratorIpAddressTypeType of cbAcceleratorIpAddress | INET-ADDRESS-MIBInetAddressType Type Values:
| .1.3.6.1.4.1.5951.7.3.4.1.1 | ||||||||||||||
| cbAcceleratorIpAddressIP Address for this managed device | INET-ADDRESS-MIBInetAddress Type Constraints: range: 0..255 | .1.3.6.1.4.1.5951.7.3.4.1.2 | ||||||||||||||
| cbAcceleratorHostIPAddressTypeType of cbAcceleratorHostIPAddress | INET-ADDRESS-MIBInetAddressType Type Values:
| .1.3.6.1.4.1.5951.7.3.4.1.3 | ||||||||||||||
| cbAcceleratorHostIPAddressHost IPAddress where VM is provisioned | INET-ADDRESS-MIBInetAddress Type Constraints: range: 0..255 | .1.3.6.1.4.1.5951.7.3.4.1.4 | ||||||||||||||
| cbAcceleratorProfileNameDevice Profile Name that is attached with this managed device | OctetString | .1.3.6.1.4.1.5951.7.3.4.1.5 | ||||||||||||||
| cbAcceleratorNameName of managed device | OctetString | .1.3.6.1.4.1.5951.7.3.4.1.6 | ||||||||||||||
| cbAcceleratorNetmaskTypeType of cbAcceleratorNetmask | INET-ADDRESS-MIBInetAddressType Type Values:
| .1.3.6.1.4.1.5951.7.3.4.1.7 | ||||||||||||||
| cbAcceleratorNetmaskNetmask of managed device | INET-ADDRESS-MIBInetAddress Type Constraints: range: 0..255 | .1.3.6.1.4.1.5951.7.3.4.1.8 | ||||||||||||||
| cbAcceleratorGatewayTypeType of cbAcceleratorGateway | INET-ADDRESS-MIBInetAddressType Type Values:
| .1.3.6.1.4.1.5951.7.3.4.1.9 | ||||||||||||||
| cbAcceleratorGatewayDefault Gateway of managed device | INET-ADDRESS-MIBInetAddress Type Constraints: range: 0..255 | .1.3.6.1.4.1.5951.7.3.4.1.10 | ||||||||||||||
| cbAcceleratorHostnameAssign hostname to managed device, if this is not provided, name will be set as host name | OctetString | .1.3.6.1.4.1.5951.7.3.4.1.11 | ||||||||||||||
| cbAcceleratorDescriptionDescription of managed device | OctetString | .1.3.6.1.4.1.5951.7.3.4.1.12 | ||||||||||||||
| cbAcceleratorVersionDevice Version | OctetString | .1.3.6.1.4.1.5951.7.3.4.1.13 | ||||||||||||||
| cbAcceleratorInstanceStateState of device, UP only if device accessible | OctetString | .1.3.6.1.4.1.5951.7.3.4.1.14 | ||||||||||||||
| cbAcceleratorUuidUUID of VM Instance | OctetString | .1.3.6.1.4.1.5951.7.3.4.1.15 | ||||||||||||||
| cbAcceleratorVmStateState of Virtual Machine (Running | Halted) | OctetString | .1.3.6.1.4.1.5951.7.3.4.1.16 | ||||||||||||||
| cbAcceleratorNumberOfCPUNumber of CPU that is assigned to VM Instance | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.5951.7.3.4.1.17 | ||||||||||||||
| cbAcceleratorVmCPUUsageCPU Usage (%) of VM Instance | OctetString | .1.3.6.1.4.1.5951.7.3.4.1.18 | ||||||||||||||
| cbAcceleratorVmMemoryTotalTotal Memory of VM Instance in MB | OctetString | .1.3.6.1.4.1.5951.7.3.4.1.19 | ||||||||||||||
| cbAcceleratorVmMemoryFreeFree Memory (MB) available in VM Instance | OctetString | .1.3.6.1.4.1.5951.7.3.4.1.20 | ||||||||||||||
| cbAcceleratorVmMemoryUsageMemory Usage (%) of VM Instance | OctetString | .1.3.6.1.4.1.5951.7.3.4.1.21 | ||||||||||||||
| cbAcceleratorUptimeUptime of device | OctetString | .1.3.6.1.4.1.5951.7.3.4.1.24 | ||||||||||||||
| cbAcceleratorIpListSpecify the list of Citrix SD-WAN IPs for which this device will act as a Citrix SD-WAN Accelerator. | OctetString | .1.3.6.1.4.1.5951.7.3.4.1.31 | ||||||||||||||
| cbAcceleratorMgmtIPAddressTypeType of cbAcceleratorMgmtIPAddress | INET-ADDRESS-MIBInetAddressType Type Values:
| .1.3.6.1.4.1.5951.7.3.4.1.38 | ||||||||||||||
| cbAcceleratorMgmtIPAddressManagement IP Address for this Managed Device | INET-ADDRESS-MIBInetAddress Type Constraints: range: 0..255 | .1.3.6.1.4.1.5951.7.3.4.1.39 |