LUM-IFFC-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
1
Rows
1
Columns
14
.1.3.6.1.4.1.8708.2.59.2.2.1 · 1 row entry · 14 columns
Uses the infinera variant from /opt/observium/mibs/infinera.
Command help
Walk ifFcPhysicalTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'LUM-IFFC-MIB' -M '/opt/observium/mibs/infinera:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'LUM-IFFC-MIB::ifFcPhysicalTable'
The Physical group contains information and
configuration for the FC physical layer.
ifFcPhysicalEntry row .1.3.6.1.4.1.8708.2.59.2.2.1.1
An entry in the ifFc physical list.
Column Syntax OID
An index assigned to each entry.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.8708.2.59.2.2.1.1.1
The management name of the optical transmission section,
for example 'clientFcPh:1:2:1-2', where the first number indicates
subrack, the second slot number and the third/fourth
are the physical port numbers.
LUM-TCMgmtNameString
Type Constraints:
range: 0..255
Description:
An octet string containing administrative
information, in human-readable form.

More or less the same as SnmpAdminString
defined in SNMP-FRAMEWORK-MIB.
.1.3.6.1.4.1.8708.2.59.2.2.1.1.2
An index that describes to which index in ifBasicIf table
this object is related.
LUM-TCUnsigned32WithNA
Type Constraints:
range: 0..4294967294
Description:
An unsigned32 integer of an object.

4294967293 used to tell that it is not
possible to read attribute at the moment.

4294967294 is used to indicate that the attribute
is not used on the object
.1.3.6.1.4.1.8708.2.59.2.2.1.1.3
The state for outgoing (TX) signal
of the interface.

down - A major fault has occurred.

degraded - The signal quality is impaired.

up - The signal is OK.
LUM-TCSignalStatusWithNA
Type Values:
1down
2degraded
3up
2147483647notApplicable
Description:
SignalStatus.
notApplicable - used to tell that attribute
is not used in current configuration.
.1.3.6.1.4.1.8708.2.59.2.2.1.1.4
The state for incoming (RX) signal
of the interface.

down - A major fault has occurred.

degraded - The signal quality is impaired.

up - The signal is OK.
LUM-TCSignalStatusWithNA
Type Values:
1down
2degraded
3up
2147483647notApplicable
Description:
SignalStatus.
notApplicable - used to tell that attribute
is not used in current configuration.
.1.3.6.1.4.1.8708.2.59.2.2.1.1.5
Remote link fault (RLF).

Reference: 1000Base-SX/LX: 37.2.1.5 RF1/RF2 IEEE 802.3ah

alarm: Active remote link fault indication.

ok: Inactive remote link fault indication.
LUM-TCFaultStatusWithNA
Type Values:
1ok
2alarm
2147483647notApplicable
Description:
A value indicating the current state
of a potential fault condition leading to
an alarm for an object.

ok - indicates that no fault condition is present
and no alarm is active or the alarm has been cleared.
.1.3.6.1.4.1.8708.2.59.2.2.1.1.6
Local link fault (LLF).

Reference: 49.2.4.5 => 46.3.4 (link_fault in 46.3.4.2) 49.2.13.3

alarm: Active local link fault indication.

ok: Inactive local link fault indication.
LUM-TCFaultStatusWithNA
Type Values:
1ok
2alarm
2147483647notApplicable
Description:
A value indicating the current state
of a potential fault condition leading to
an alarm for an object.

ok - indicates that no fault condition is present
and no alarm is active or the alarm has been cleared.
.1.3.6.1.4.1.8708.2.59.2.2.1.1.7
Link down.

alarm: Failure to negotiate a connection with the
other party.

ok: A connection is negotiated.
LUM-TCFaultStatusWithNA
Type Values:
1ok
2alarm
2147483647notApplicable
Description:
A value indicating the current state
of a potential fault condition leading to
an alarm for an object.

ok - indicates that no fault condition is present
and no alarm is active or the alarm has been cleared.
.1.3.6.1.4.1.8708.2.59.2.2.1.1.8
Rx PCS Loss of sync.

A: FC 'frame' can not be located.

D: FC 'frame' is located.
LUM-TCFaultStatusWithNA
Type Values:
1ok
2alarm
2147483647notApplicable
Description:
A value indicating the current state
of a potential fault condition leading to
an alarm for an object.

ok - indicates that no fault condition is present
and no alarm is active or the alarm has been cleared.
.1.3.6.1.4.1.8708.2.59.2.2.1.1.9
Tx PCS Loss of sync.

A: FC 'frame' can not be located.

D: FC 'frame' is located.
LUM-TCFaultStatusWithNA
Type Values:
1ok
2alarm
2147483647notApplicable
Description:
A value indicating the current state
of a potential fault condition leading to
an alarm for an object.

ok - indicates that no fault condition is present
and no alarm is active or the alarm has been cleared.
.1.3.6.1.4.1.8708.2.59.2.2.1.1.10
Rx High bit error rate (Hi-Ber).

alarm: Active high bit error rate.

ok: Inactive high bit error rate.
LUM-TCFaultStatusWithNA
Type Values:
1ok
2alarm
2147483647notApplicable
Description:
A value indicating the current state
of a potential fault condition leading to
an alarm for an object.

ok - indicates that no fault condition is present
and no alarm is active or the alarm has been cleared.
.1.3.6.1.4.1.8708.2.59.2.2.1.1.11
Rx Local link fault (LLF).

alarm: Active local link fault indication.

ok: Inactive local link fault indication.
LUM-TCFaultStatusWithNA
Type Values:
1ok
2alarm
2147483647notApplicable
Description:
A value indicating the current state
of a potential fault condition leading to
an alarm for an object.

ok - indicates that no fault condition is present
and no alarm is active or the alarm has been cleared.
.1.3.6.1.4.1.8708.2.59.2.2.1.1.12
Tx Local link fault (LLF).

alarm: Active local link fault indication.

ok: Inactive local link fault indication.
LUM-TCFaultStatusWithNA
Type Values:
1ok
2alarm
2147483647notApplicable
Description:
A value indicating the current state
of a potential fault condition leading to
an alarm for an object.

ok - indicates that no fault condition is present
and no alarm is active or the alarm has been cleared.
.1.3.6.1.4.1.8708.2.59.2.2.1.1.13
Tx High bit error rate (Hi-Ber).

alarm: Active high bit error rate.

ok: Inactive high bit error rate.
LUM-TCFaultStatusWithNA
Type Values:
1ok
2alarm
2147483647notApplicable
Description:
A value indicating the current state
of a potential fault condition leading to
an alarm for an object.

ok - indicates that no fault condition is present
and no alarm is active or the alarm has been cleared.
.1.3.6.1.4.1.8708.2.59.2.2.1.1.14