LENOVO-XCC-ALERT-MIB

        This MIB is used by the XCC to define traps for Alert conditions detected by the management firmware.
    
Source file
LENOVO-XCC-ALERT-MIB
Last revised
Identity
lenovoXCCAlertMIB
Base OID
1.3.6.1.4.1.19046.11.1.158.5
Net-SNMP examples using the ibm MIB directory Show commands

These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.

Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'LENOVO-XCC-ALERT-MIB' -M '/opt/observium/mibs/ibm:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'LENOVO-XCC-ALERT-MIB::lenovoXCCAlertMIB'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'LENOVO-XCC-ALERT-MIB' -M '/opt/observium/mibs/ibm:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'LENOVO-XCC-ALERT-MIB::lenovoXCCAlertMIB'
How SNMP, Net-SNMP, MIB paths, and variants work
Objects (28)
lenovoXCCAlertMIB.1.3.6.1.4.1.19046.11.1.158.5
.1.3.6.1.4.1.19046.11.1.158.5.1
altDateTimemandatory
RFC1213-MIBDisplayString.1.3.6.1.4.1.19046.11.1.158.5.1.1
altMsgIDmandatory
Integer32.1.3.6.1.4.1.19046.11.1.158.5.1.10
RFC1213-MIBDisplayString.1.3.6.1.4.1.19046.11.1.158.5.1.11
RFC1213-MIBDisplayString.1.3.6.1.4.1.19046.11.1.158.5.1.12
RFC1213-MIBDisplayString.1.3.6.1.4.1.19046.11.1.158.5.1.13
altHostRoomIDmandatory
RFC1213-MIBDisplayString.1.3.6.1.4.1.19046.11.1.158.5.1.14
altHostRackIDmandatory
RFC1213-MIBDisplayString.1.3.6.1.4.1.19046.11.1.158.5.1.15
RFC1213-MIBDisplayString.1.3.6.1.4.1.19046.11.1.158.5.1.16
RFC1213-MIBDisplayString.1.3.6.1.4.1.19046.11.1.158.5.1.17
altEventIDmandatory
RFC1213-MIBDisplayString.1.3.6.1.4.1.19046.11.1.158.5.1.18
Enumeration.1.3.6.1.4.1.19046.11.1.158.5.1.19
altTestmandatory
Enumeration.1.3.6.1.4.1.19046.11.1.158.5.1.20
RFC1213-MIBDisplayString.1.3.6.1.4.1.19046.11.1.158.5.1.21
altHostMTMmandatory
RFC1213-MIBDisplayString.1.3.6.1.4.1.19046.11.1.158.5.1.22
altAuxDatamandatory
RFC1213-MIBDisplayString.1.3.6.1.4.1.19046.11.1.158.5.1.23
RFC1213-MIBDisplayString.1.3.6.1.4.1.19046.11.1.158.5.1.24
altEventTypemandatory
Integer32.1.3.6.1.4.1.19046.11.1.158.5.1.25
altDetectorIDmandatory
RFC1213-MIBDisplayString.1.3.6.1.4.1.19046.11.1.158.5.1.26
RFC1213-MIBDisplayString.1.3.6.1.4.1.19046.11.1.158.5.1.27
RFC1213-MIBDisplayString.1.3.6.1.4.1.19046.11.1.158.5.1.28
altRedfishURLmandatory
RFC1213-MIBDisplayString.1.3.6.1.4.1.19046.11.1.158.5.1.29
altSpTxtIdmandatory
RFC1213-MIBDisplayString.1.3.6.1.4.1.19046.11.1.158.5.1.3
altSysUuidmandatory
RFC1213-MIBDisplayString.1.3.6.1.4.1.19046.11.1.158.5.1.5
altSysSernmandatory
RFC1213-MIBDisplayString.1.3.6.1.4.1.19046.11.1.158.5.1.6
altPrioritymandatory
Integer32.1.3.6.1.4.1.19046.11.1.158.5.1.8
altMsgTextmandatory
RFC1213-MIBDisplayString.1.3.6.1.4.1.19046.11.1.158.5.1.9
Dependencies (10) 4 direct · 6 transitive Show tree and compile order Hide dependency details

Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.

Dependency tree
Notifications / Traps (34)
NameOIDDescription
.1.3.6.1.4.1.19046.11.1.158.5.0.0
Critical Alert: Temperature threshold exceeded.
.1.3.6.1.4.1.19046.11.1.158.5.0.1
Critical Alert: Voltage threshold exceeded.
.1.3.6.1.4.1.19046.11.1.158.5.0.10
Non-Critical Alert: Redundant Power Supply failure.
.1.3.6.1.4.1.19046.11.1.158.5.0.100
System Alert: Test trap.
.1.3.6.1.4.1.19046.11.1.158.5.0.11
Critical Alert: Single Fan failure.
.1.3.6.1.4.1.19046.11.1.158.5.0.12
Non-Critical Alert: Temperature threshold exceeded.
.1.3.6.1.4.1.19046.11.1.158.5.0.13
Non-Critical Alert: Voltage threshold exceeded.
.1.3.6.1.4.1.19046.11.1.158.5.0.164
Non-Critical Alert: Power.
.1.3.6.1.4.1.19046.11.1.158.5.0.165
Non-Critical Alert: Fan Error.
.1.3.6.1.4.1.19046.11.1.158.5.0.21
System Alert: OS Timeout value exceeded.
.1.3.6.1.4.1.19046.11.1.158.5.0.22
System Alert: Application Alert. Refer to Message ID for specific condition.
.1.3.6.1.4.1.19046.11.1.158.5.0.23
System Alert: Power Off.
.1.3.6.1.4.1.19046.11.1.158.5.0.24
System Alert: Power On.
.1.3.6.1.4.1.19046.11.1.158.5.0.25
System Alert: System Boot Failure.
.1.3.6.1.4.1.19046.11.1.158.5.0.26
System Alert: OS Loader Timeout.
.1.3.6.1.4.1.19046.11.1.158.5.0.27
System Alert: Predictive Failure Analysis(PFA) information.
.1.3.6.1.4.1.19046.11.1.158.5.0.30
Sev-Off Alert: Event Remote Login.
.1.3.6.1.4.1.19046.11.1.158.5.0.31
System Alert: All other audit events.
.1.3.6.1.4.1.19046.11.1.158.5.0.35
System Alert: System Log 75% full.
.1.3.6.1.4.1.19046.11.1.158.5.0.36
Critical Alert: Incompatible hardware configuration.
.1.3.6.1.4.1.19046.11.1.158.5.0.37
System Alert: Network change notification.
.1.3.6.1.4.1.19046.11.1.158.5.0.38
System Alert: Host NIC link state(down/up).
.1.3.6.1.4.1.19046.11.1.158.5.0.39
System Alert: Drive Hotplug.
.1.3.6.1.4.1.19046.11.1.158.5.0.4
Critical Alert: Power failure.
.1.3.6.1.4.1.19046.11.1.158.5.0.40
Critical Alert: CPU Error.
.1.3.6.1.4.1.19046.11.1.158.5.0.41
Critical Alert: Memory Error.
.1.3.6.1.4.1.19046.11.1.158.5.0.42
Non-Critical Alert: CPU Error.
.1.3.6.1.4.1.19046.11.1.158.5.0.43
Non-Critical Alert: Memory Error.
.1.3.6.1.4.1.19046.11.1.158.5.0.5
Critical Alert: Hard disk drive failure.
.1.3.6.1.4.1.19046.11.1.158.5.0.50
Critical Alert: Other Failure - refer to Message ID for specific condition.
.1.3.6.1.4.1.19046.11.1.158.5.0.51
Critical Alert: PCIe events.
.1.3.6.1.4.1.19046.11.1.158.5.0.60
Non-Critical Alert: Warning - refer to Message ID for specific condition.
.1.3.6.1.4.1.19046.11.1.158.5.0.61
Non-Critical Alert: PCIe events.
.1.3.6.1.4.1.19046.11.1.158.5.0.9
Critical Alert: Redundant Power Supply failure.