Juniper-REDUNDANCY-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
1
Rows
1
Columns
9
.1.3.6.1.4.1.4874.2.2.74.1.3.3
·
1 row entry
·
9 columns
Uses the junose variant from
Command help
/opt/observium/mibs/junose.
Walk juniRedundancySystemActivationHistoryTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'Juniper-REDUNDANCY-MIB' -M '/opt/observium/mibs/junose:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Juniper-REDUNDANCY-MIB::juniRedundancySystemActivationHistoryTable'
A table that tracks the history of all reloads and switchovers that have occurred since system is powered on. The maximum number of entries permissible in this table is defined by juniRedundancySystemActivationHistoryTableMaxLength. When the number of entries in the table reaches the maximum limit, the next entry would replace the oldest existing entry in the table.
The entries in this table contain the reload and switchover information.
Each entry in the table is indexed by juniRedundancySystemActivationHistoryIndex.
The index wraps around to 1 after reaching the maximum value.
Each entry in the table is indexed by juniRedundancySystemActivationHistoryIndex.
The index wraps around to 1 after reaching the maximum value.
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
An integer value for the purpose of indexing system
activation history table. After reaching maximum value as indicated by juniRedundancySystemActivationHistoryTableMaxLength, it wraps around to 1. |
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.4874.2.2.74.1.3.3.1.1 |
||||||||||
|
Indicates the nature of the reset - reload or switchover - and the slot
types involved. Depending on the value of this object, certain elements of JuniRedundancySystemActivationHistoryEntry will not be applicable. |
JuniRedundancyResetType Type Values:
|
.1.3.6.1.4.1.4874.2.2.74.1.3.3.1.2 |
||||||||||
|
Indicates the activation type of the particular historical system
activation entry with respect to the slot types involved. |
JuniRedundancySystemActivationType Type Values:
|
.1.3.6.1.4.1.4874.2.2.74.1.3.3.1.3 |
||||||||||
|
Indicates the slot number of active SRP or line card that went down.
|
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.4874.2.2.74.1.3.3.1.4 |
||||||||||
|
Indicates the system-wide boot release file name of the slot indicated
by juniRedundancyHistoryPrevActiveSlot. |
SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.4874.2.2.74.1.3.3.1.5 |
||||||||||
|
Indicates the slot number of standby SRP or spare line card that took over.
|
Integer32 Constraints: range: 0-255 |
.1.3.6.1.4.1.4874.2.2.74.1.3.3.1.6 |
||||||||||
|
Indicates the system-wide boot release file name of the slot indicated
by juniRedundancyHistoryCurrActiveSlot. |
SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.4874.2.2.74.1.3.3.1.7 |
||||||||||
|
Indicates the reason for reload or switchover of the slots involved.
|
JuniRedundancyResetReason Type Values:
|
.1.3.6.1.4.1.4874.2.2.74.1.3.3.1.8 |
||||||||||
|
Indicates the date and time when the reload or switchover of the slots
occurred. |
SNMPv2-TCDateAndTime Type Constraints: range: 8range: 11Description: A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month … |
.1.3.6.1.4.1.4874.2.2.74.1.3.3.1.9 |